Home

TE- 300/500W –WV Series Inverters User Manual

image

Contents

1. solar panels on time and can track the highest voltage and current VI Then made the inverter discharge to power grid with the highest efficiency The peak voltage Vpp of the solar panels is about 19 5V when it in factory And the environment temperature is 25 C The reason of setting this temperature interestingly different from the subjective imagination we ordinary people the conclusion may let us surprised is that when the weather is very hot solar panels peak voltage will fall to about 17 5 V while in cold weather the peak voltage can achieve 20 8 V Now we back to contrast the difference of MPPT solar energy grid inverter and traditional inverter The traditional solar inverter is a bit like the manual gearbox When the engine speed increase while the gearbox gear don t increase at the same time it will definitely affect the speed of the car For traditional inverter speaking the parameter output power is been set in factory It likes a car have been fixed set on fixed 1 gears no matter how powerfully you trample accelerator the speed of a car IS limited While have the MPPT function it will be different it is automatically It will automatically adjust the gears according to the engine speed so it can make cars in the most gears in a reasonable efficiency standard operation It means the MPPT controller can track the maximum power point of solar panels in real time then express the biggest efficiency of solar panels The higher t
2. adjust from the maximum to the minimum 4 In automatic adjustment process we will see the LOW light flashing And the power will keep as a starting point from 0 to the maximum output power and it will restart at most for 6 times then locked in the maximum power the ST lamp long bright 5 It need 10 minutes for 6 grade power search Wide voltage input 22 60VDC Achieve wide voltage input I DC voltage input 22 60VDC 2 Second level power variable voltage conversion High frequency two way and one way grid function I High frequency direct modulation AC half wave synthesis 2 Two way grid means Load consume directly And can reverse AC current transmission 3 One way grid means Load consume directly And banned reverse AC current transmission Kinds of frequency output function It can apply to 50Hz and 60Hz frequency of AC Frequency range 45Hz 53Hz 55Hz 63Hz directly connected to the solar panels do not need to connect the battery Using precise Dynamic differential pressure type MPPT function APL functions the inverter automatically adjust the solar panels of maximum output power simply connect the solar panel to the grid inverters Do not need to connect the battery I Differential pressure type MPPT 0 1 V accuracy 2 Power lock 10W AC output AC 0 angle with high precision auto detection AC phase angle of 0 through isolation amplifier then input to the MCU for high precision detection and analysis The pha
3. TE 300 500W WV Series Inverters User Manual System Function Display function I AC voltage display When the 125VAC LED lit up it means the AC output is 125V When the 230V AC LED lit up it means the AC output is 230V 2 Outage display When the Fault LED lit up is means there is no electricity or the output is fail and the inverter restart 3 Power shows Power output LED The 5 red LEDS take turns lighting the quicker the lights move the more power output 4 AC frequency display When the 50Hz LED lit up it means the input frequency is 50Hz When the 60Hz LED lit up it means the input frequency is 60Hz 5 DC over voltage display When the Fault LED and the HIGH LED lit up it means the DC input is over 62 VDC 6 DC under voltage display When the Fault LED and the LOW LED lit up it means the DC input is low 22VDC 7 Power adjust display 1 When ST LED flashing it means power is in adjusting condition a When the ST LED and HIGH LED lit up it means the power is increase b When the ST LED and LOW LED lit up it means the power is decrease 2 When ST LED long on time is means the power is locked and the inverter works 6 grade power search In overcast weather the solar battery s output current is extremely tiny then inverter will automatic open 6 grade power search function 2 The program can automatically open power adjustment for 6 times 3 The current direction can
4. he voltage the more power can be output through the MPPT Thus improve the charging efficiency Theoretically speaking using MPPT the efficiency can be increased by 50 compared with the traditional inverter But due to environmental impact and various around energy loss the ultimate efficiency can improve 20 30 according to our actual testing Parameter Table KD WVC Grid series models 300Watt 500Watt Recommend use solar panels 400Wp 600Wp DC MAX input current 20A 40A AC MAX output power 300Watt 500Watt DC MAX Open circuit 100VDC input voltage DC input voltage range 22 60VDC MAX output power factor 0 99 DC input Reverse voltage protection FUSE AC output voltage range 120V versions 90 140VAC 230V versions 180 260VAC AC frequency range 45 53Hz 55 63Hz Output current total THDIAC lt 5 harmonic distortion AC Phase lt 0 5 Islanding protection VAC f AC Output short circuit protection Current limiting Show LED mode power instruction voltage instruction AC frequency instruction over voltage instruction om mw Pr 4 arin EEE 0 99 Indoor Type Design Packing and weight N W Each inverter 1 3KG 300W 500W G W Each inverter 1 8KG 300W 500W Each inverter size L x W x H 21 x 16 5 x5 3CM Inner carton size L x W x H 30x20 3x11 3CM Master carton size Lx W x H 42x31 5x36 5CM 6 pieces carton N W Outer packing 10 8KG 300W 500W G W Outer packing 11 5KG 300W 500W AC power cord le
5. ng integral AD sampling method Power Automatically Locked APL In different current fluctuations we should use the MPPT function When the MPPT function adjusted to the maximum power point the product automatically powers locked in maximum power point then made the output power more stable I Power lock The biggest sampling point of MPPT Automatically Adapt To Different Load Power Factor Adapt to any of the power load Constant Current Constant Power This product is constant current constant output power without any overload over current phenomenon Automatically Shut Down When The Power Output Of a Fault When the city power system is in failure the inverter will automatically turn off the output Current Limit Protection Current limit Stack Multiple Machines Multiple small power inverters in parallel can achieve large output power High Frequency High Conversion Rate Adapt high frequency converter the output more efficient Maximum Power Point Tracking MPPT Because the current intensity and the voltage changes at any time if there is no power point tracking there will be a lot of problems In the past time usually adopt a solar controller but this product uses high precision MPPT operation power automatic and immediate adjust the solar panels output power at the maximum output point then achieve a stable output purposes MPPT is for short of Maximum Power Point Tracking It means the controller can sense the voltage of the
6. ngth 1 8M User Guide 1 Installation Connection 1 Red terminal Connect DC positive black terminal Connect DC negative Show in Figure 1 Figure 1 DC negative terminals DC positive terminal solar panels grid tie inverter 2 AC socket Connect to the mains Put the side of the AC cord which has holes into the inverter with 3 foot outlet and the other side of the AC cord to home 3PIN AC outlet Show in Figure 2 Figure 2 Figure 3 EN ENN eee eet switch of the inverter 3 Switch Connect the connections in right way then turn on the switch The inverter starts to work 3 Stack using In order to achieve higher power use requirements this product can be stacked such as 4 grid inverter1000W stacking can achieve 4000W And the number of the stacking is unlimited Used as shown in Figure 6 Figure 6 connection to power grid 4 Input and output 1 DC input limit lt Input voltage range 22V to 60V Solar Panel Recommend using the power more than 30W 1 Reference voltage is 18V s solar panel Suggest using two pieces of solar panel in series 2 Reference voltage is 36V s solar panel 3 Reference voltage is 48V s solar panel Recommend using multiple solar panels Solar panel in series will result in high input voltage which will exceed the working voltage range of the inverter Wind turbine system Rated voltage 24VDC maximum voltage 48VDC 2 AC output lt gt Voltage range of the inverter whose o
7. se shift rate is less than 1 thus achieve high precision with phase modulation AC output together 1 AC phase shift lt 1 2 Over zero protection 0 2 VAC 3 AC switching 50Hz 60Hz Synchronous High frequency Modulation In the process of the grid usually adapt the same phase angle in parallel ie When the two phase alternating current total is equal to 0 Use switch to combination the two AC fusion and the product is rectified AC half frequency AC to 100Hz first then the machine use the high frequency current in the circuit and semi 100Hz frequency alternating current generated combination to achieve high frequency modulation I Modulation synthesis half wave and full bridge modulation synthesis 100Hz 120Hz 2 Synthetic way MOSFET full bridge 3 High frequency SOKHz Pure Sine Wave Output Use SPWM directly to make pure sine wave output I Output waveform Adopt complementary PWM to push pull pure sine wave 2 Generate means enhancement mode SPWM Automatic Sensing Function Solar Luminosity Use the latest luminosity perception operation technology The different illuminate angle and intensity of the solar panel will produce different current output Use advanced CPU to operate the different illuminance and the data can be directly displayed on the LCD Then you can visually see the sense of the strength of the sun unit Used more convenient 1 Luminosity sampling point power sampling point 2 High precision AD sampli
8. utput is 220V AC 180V 260V 50HZ lt gt Voltage range of the inverter whose output is 110V AC 90V 140V 60HZ Notes Non professionals do not disassemble Only qualified personnel may repair this product Please install inverter in the low humidity and well ventilated place to avoid the inverter over heating and clear around the inflammable and explosive materials When using this product avoid children touching playing to avoid electric shock Recommended Maximum DC input 4AWG cable capable of handling more than 50A of the cable size Optimal length of the DC input line 8M or less long cable will allow solar panels to the inverter DC voltage drop caused by wear and tear Connected to a power outlet to provide AC Connected solar panels battery or wind generators DC input DC power supply cable Proposed wind power plant with its own charge controller and load dump Accessories for product One standard AC wire One user manual

Download Pdf Manuals

image

Related Search

Related Contents

Osprey 800e Series User Guide  Soldadura  2540B/2542B DSO User Manual - 首頁  Altec Lansing 1207C User's Manual  CURRICULUM VITAE - Université de Sherbrooke  sanitary - heating - air-conditioning  O que é Análise de Risco?  MONOGRAPHIE DE PRODUIT TRI-CYCLEN Comprimés    3- flying with the x-alps gto harness  