Home

GT15 Ethernet communication unit User`s Manual

image

Contents

1. 1 This depends on the specifications of the Ethernet network sys tem to which the GOT is connected For the details refer to the manual of Ethernet module of con nected PLC 2 If multiple network equipments including GOT are connected within a segment the network load would increase In such condition the communication performance between GOT and PLC may be declined The decline of the communication performance may be improved by the following measures Using switching hubs Reducing the number of monitoring devices of the GOT 2 2 Specifications of the related devices Use the connection cable and the hub which meet the IEEE802 3 10BASE T 100BASE TX standard Specifications Item 10BASE T 100BASE TX Non shielded twisted pair Shielded twisted pair wire Cable wire UTP cable STP cable category3 4 5 category5 Connector RJ45jack RJ45jack Hub 10Mbps hub 100Mbps hub No Name Description Mounting screws fixed with a front 1 Mounting screw extension unit or GOT Extension connector installed to a front 2 Interface connector extension unit or the GOT Extension connector to which a back 3 Extension connector extension unit is installed Connector to which Ethernet cable is 4 Ethernet connector connected It lights up during 100 Mbps 5 100M LED eis transmission See the List of valid devices applicable for GOT10
2. control wires or communication cables with the main circuit or power wires or lay them close to each other As a guide separate the lines by a distance of at least 100 mm 3 94 inch otherwise malfunctions may occur due to noise INSTALLATION PRECAUTIONS lt gt DANGER Be sure to shut off all phases of the external power supply used by the system before mounting or removing this unit to from the GOT Not doing so can cause a unit failure or malfunction Before connecting the Bus connection cable to this unit always shut off GOT power and PLC CPU power externally in all phases Not doing so can cause a malfunction CAUTION Use this unit in the environment given in the general specifications of GT15 User s Manual Not doing so can cause an electric shock fire malfunction or product damage or deterioration When installing this unit to the GOT fit it to the connection interface of the GOT and tighten the mounting screws in the specified torque range Undertightening can cause a drop failure or malfunction Overtightening can cause a drop failure or malfunction due to screw or unit damage WIRING PRECAUTIONS lt gt DANGER Be sure to shut off all phases of the external power supply used by the system before wiring Failure to do so may result in an electric shock product damage or malfunctions CAUTION Use crimp contact pressure displacement or soldering to wire the connectors for e
3. 00 series GOT A 0010 for information about models whose operations have been confirmed For technical documents please contact your local Mitsubishi representative When using any model not mentioned in the List of valid devices applicable for GOT1000 series the model may not work normally The Technical News above is available as a reference at the information site for Mitsubishi industrial automation products MELFANSweb website http wwwf2 mitsubishielectric co jp 6 SD RD LED It blinks during data sending receiving 7 Rating plate english index html 3 Part Names and External Dimensions 63 2 48 GOT main unit 4 0 83 Dimensions of X when the Ethernet communication unit is mounted to the GOT 15 10 4 21 0 83 12 1 18 0 71 8 4 5 7 23 0 91 unit mm inch 4 Installation Procedure 1 Power off the GOT 2 Remove one extension unit cover of the GOT 4 Fasten the Ethernet communication unit by tightening its mounting screws 2 places with tightening torque 0 36 to 0 48 Nem 5 When installing an extension unit on the unit that has been installed remove the connector cover and the sticker When not installing an extension unit on the unit that has been installed in order to avoid receiving electrostatic stick accessory stickers to cover the top of mountin
4. MITSUBISHI GT15 Ethernet communication unit User s Manual GT15 J71E71 100 Thank you for purchasing the GOT1000 Series Prior to use please read both this manual and detailed manual thoroughly to fully understand the product MODEL GT15 J71E71 100 U MODEL CODE 1D7M29 IB NA 0800314 F 0707 MEE GRAPHIC OPERATION TERMINAL GOTio900 SAFETY PRECAUTIONS Always read these precautions before using this equipment Before using this product please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly The precautions given in this manual are concerned with this prod uct l l l l l I l n this manual the safety precautions are ranked as DANGER and CAUTION Indicates that incorrect handling may cause O DANGER hazardous conditions resulting in death or severe injury Indicates that incorrect handling may cause A CAUTION hazardous conditions resulting in medium or slight personal injury or physical damage Note that the A CAUTION level may lead to a serious accident according to the circumstances Always follow the precautions of both levels because they are impor tant to personal safety Please save this manual to make it accessible when required and always forward it to the end user DESIGN PRECAUTIONS lt gt DANGER Do not bunch the
5. al for the general specifications of Manuals The following shows manuals relevant to this product Detailed Manual Manualaame Manual Number Model code GT15 User s Manual SH 080528ENG Sold separately 1D7M23 GOT1000 Series Connection Manual SH 080532ENG Sold separately 1D7M26 Relevant Manuals For relevant manuals refer to the PDF manual stored within the drawing software used 2005 MITSUBISHI ELECTRIC CORPORATION Compliance with the EMC and Low Voltage Directives When incorporating the Mitsubishi GOT into other machinery or equipment and keeping compliance with the EMC and low voltage directives refer to EMC AND LOW VOLTAGE DIRECTIVE of GT15 User s Manual The CE logo is printed on the rating plate of the GOT indicating compliance with the EMC and low voltage directives the GOT Item Specification Data transfer method 10BASE T 100BASE TX Transmissi n Base band Base band method Transmission Maximum nee 200m 200m Pea mode distance specifications Maximum segment length 100m 100m Maximum number of cascade connection 4 steps 2 steps Only 1 unit can be mounted Number of units mounted to GOT to the extension unit interface Number of GOTs 128 Recommend 16 or Connecting connected less 1 2 condition z GOT placing PER distance Internal current consumption 5VDC 0 224A Weight 0 09kg 0 20Ib
6. e unit A CAUTION Dispose of this product as industrial waste A CAUTION Make sure to transport the GOT main unit and or relevant unit s in the manner they will not be exposed to the impact exceeding the impact resistance described in the general specifications of GT15 User s Manual as they are precision devices Failure to do so may cause the unit to fail Check if the unit operates correctly after transportation Packing List The following items are included Wedel Product Tuan GT15 J71E71 100 Ethernet communication unit l 1 Mounting screw set 2 screws 2 stickers 1 1 Overview This User s Manual describes the GT15 Ethernet communication unit The GT15 J71E71 100 is required for the operations such as the Ethernet connection or Gateway function with GOT For attachable GOTs refer to GT15 User s Manual When using the Ethernet connection make the communication settings to perform communication between the GOT and PLC Refer to GOT1000 Series Connection Manual for details of Ethernet connection For information concerning necessary OS in case of using GT15 J71E71 100 refer to GOT 1000 Series Connection Manual 2 Specifications 2 1 Performance Specifications The performance specifications of the Ethernet communication unit are indicated below The general specifications of the Ethernet communication unit are the same as those of the GOT Refer to GT15 User s Manu
7. g screws 2 places Keep the connector cover fixed Keep the sticker stuck as it is Accessory stickers Connector cover Sticker 1 Grounding work for the 10BASE T and 100BASE TX requires appropriate safety measures Consult professionals for work details including terminal of connection cables and other plant work such as laying of main cables 2 If you remove the Ethernet unit detach it from specified direction shown PULL so as not to break a connector Ethernet is a registered trademark of Xerox Corporation U S Other business or product names mentioned herein are a trademark or registered trademark of each company Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi machine damage or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties Z For safe use This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi This product ha
8. h Point Hong Kong Tel 852 2887 8870 China Mitsubishi Electric Automation Shanghai Ltd 4 F Zhi Fu Plazz No 80 Xin Chang Road Shanghai 200003 China Tel 86 21 6120 0808 Taiwan Setsuyo Enterprise Co Ltd 6F No 105 Wu Kung 3rd Rd Wu Ku Hsiang Taipei Hsine Taiwan Tel 886 2 2299 2499 Korea Mitsubishi Electric Automation Korea Co Ltd 1480 6 Gayang dong Gangseo ku Seoul 157 200 Korea Tel 82 2 3660 9552 Mitsubishi Electric Asia Pte Ltd 307 Alexandra Road 05 01 02 Mitsubishi Electric Building Singapore 159943 Tel 65 6470 2460 Thailand Mitsubishi Electric Automation Thailand Co Ltd Bang Chan Industrial Estate No 111 Moo 4 Serithai Rd T Kannayao A Kannayao Bangkok 10230 Thailand Tel 66 2 517 1326 Indonesia P T Autoteknindo Sumber Makmur Muara Karang Selatan Block A Utara No 1 Kav No 11 Kawasan Industri Pergudangan Jakarta Utara 14440 P O Box 5045 Jakarta 11050 Indonesia Tel 62 21 6630833 India Messung Systems Pvt Ltd Electronic Sadan NO III Unit No15 M I D C Bhosari Pune 411026 India Tel 91 20 2712 3130 Australia Mitsubishi Electric Australia Pty Ltd 348 Victoria Road Rydalmere N S W 2116 Australia Tel 61 2 9684 7777 xMITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN NAGOYA WORKS 1 14 YADA MINAMI 5 CHOME HIGASHI KU NAGOYA JAPAN Singapore When exported from Japan this manual does not require ap
9. plication to the Ministry of Economy Trade and Industry for service transaction permission Specifications subject to change without notice Printed in Japan on recycled paper
10. s been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system Country Region Sales office Tel USA Mitsubishi Electric Automation Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 U S A Tel 1 847 478 2100 Brazil MELCO TEC Rep Com e Assessoria Tecnica Ltda Rua Correia Dias 184 Edificio Paraiso Trade Center 8 andar Paraiso Sao Paulo SP Brazil Tel 55 11 5908 8331 Germany Mitsubishi Electric Europe B V German Branch Gothaer Strasse 8 D 40880 Ratingen GERMANY Tel 49 2102 486 0 U K Mitsubishi Electric Europe B V UK Branch Travellers Lane Hatfield Hertfordshire AL10 8XB U K Tel 44 1707 276100 Italy Mitsubishi Electric Europe B V Italian Branch Centro Dir Colleoni Pal Perseo Ingr 2 Via Paracelso 12 I 20041 Agrate Brianza Milano Italy Tel 39 039 60531 Spain Mitsubishi Electric Europe B V Spanish Branch Carretera de Rubi 76 80 E 08190 Sant Cugat del Valles Barcelona Spain Tel 34 93 565 3131 France Mitsubishi Electric Europe B V French Branch 25 Boulevard des Bouvets F 92741 Nanterre Cedex France TEL 33 1 5568 5568 South Africa Circuit Breaker Industries Ltd Private Bag 2016 ZA 1600 Isando South Africa Tel 27 11 928 2000 Hong Kong Mitsubishi Electric Automation Hong Kong Ltd 10th Floor Manulife Tower 169 Electric Road Nort
11. xternal connections properly using the manufacturer specified tools If the connection is incomplete it may cause the module to short circuit catch fire or malfunction Connect the connectors to the unit securely Always secure the cables connected to the unit e g run them in conduits or clamp them Not doing so can cause unit or cable damage due to dangling moved or accidentally pulled cables or can cause a malfunction due to a cable contact fault STARTUP AND MAINTENANCE PRECAUTIONS lt gt DANGER Before starting cleaning always shut off GOT power externally in all phases Not doing so can cause a unit failure or malfunction DISPOSAL PRECAUTIONS TRANSPORTATION PRECAUTIONS CAUTION Do not disassemble or modify any unit This will cause failure malfunction injuries or fire Do not touch the conductive areas and electronic parts of this unit directly Doing so can cause a unit malfunction or failure Exercise care to avoid foreign matter such as chips and wire offcuts entering the unit Not doing so can cause a fire failure or malfunction Do not hold the cable part when unplugging any cable connected to the unit Doing so can cause unit or cable damage or a malfunction due to a cable contact fault Always make sure to touch the grounded metal to discharge the electricity charged in the body etc before touching the unit Failure to do so may cause a failure or malfunctions of th