Home
ZX trolley. - BOC e-catalogue
Contents
1. MZA BOC A Member of The Linde Group User manual 7X trolley 02 User manual ZX trolley ZX trolley Safe transportation for medical gas cylinders Important Please read this manual carefully before attempting to use the BOC Healthcare ZX trolley as it contains important information on the proper care handling and use of the equipment Keep this manual with the equipment or alternatively in a central place Note there is a label on the trolley with brief user instructions The safety and performance of the trolley depends not only on the trolley but also on the ancillary equipment used with it Ensure any ancillary equipment especially cylinders are compatible with the trolley These instructions should be retained for reference during the life of the product If you have any questions concerning the material contained in this manual please contact BOC Healthcare on 08456 447 764 Fire and explosion risk when transporting gases When handling medical gases in cylinders the following precautions should be followed Some materials which do not normally burn in air will burn in an atmosphere of oxygen nitrous oxide or gas mixtures containing more than 21 oxygen These gases do not burn themselves but strongly Support combustion and therefore special attention should be directed to the hazards associated with smoking and naked flames When using medical gas cylinders it is most important that no part of the cyl
2. more convenient and provide your patients with additional benefits Hl Demand valve location device Incorporated in the trolley design is a convenient location device for holding demand valves and face masks Safety locking device handle and rubber straps Your ZX trolley has an easy to use cylinder locking strap which will allow you to quickly and safely secure or release the cylinder Once the cylinder is secured on the trolley with the strap movement is restricted to help prevent damage and reduce noise levels for a quieter environment for your patients User manual ZX trolley MAA Safety locking device handle and rubber straps 2 B Rubber mat Foot plate Instruction label Conveniently located on the trolley are basic operating instructions that should be followed in order to avoid personal injury or damage to the equipment Anti static wheels The ZX trolley features large anti static wheels to ensure easy and safe movement around the hospital Foot plate and rubber mat The innovative design of your new trolley incorporates protective features that help to maintain the trolley in tip top condition Bumpers and bungs under the footplate and the rubber mat help to prevent paint chipping and damage in order to keep the trolley looking clinically smart to suit the modern healthcare environment Operating precautions The ZX trolley is intended for use in medical facilities by porters or medic
3. above are worn or damaged remove the equipment from use contact BOC Healthcare and replace any faulty parts with new Spare parts If there is any damage to the steel frame please contact BOC Healthcare for further instructions 5 Spares and accessories To maintain standards compliance use only the following spares and accessories with this product 5 1 Spares Part no Part name 19310995 Kit rubber strap assembly includes handle strap screws and plates 19310996 Kit wheels and fixing 19310997 Kit rubber base plate 19310998 Kit bumpers bungs and screws 19311712 Safety strap for handle 19310982 Adhesive instruction label 06 User manual ZX trolley 6 Environmental issues There are no known risks associated with disposal of the cylinder trolley at the end of its working life To preserve resources and to protect the environment BOC Healthcare recommends that customers should extend the trolley s life span by replacing worn parts with new spare parts whenever it is feasible 7 Reporting complaints If a complaint is made immediately inform BOC Healthcare on free phone 08456 447 764 and we will ask you the following details Customer name and address Nature of the complaint and any serious consequences which may have arisen Person you wish to receive the investigation report if required Then segregate and label the equipment and await instructions from BOC Healthcare 8 Specificat
4. al personnel To minimise the risk of injury or damage to the equipment the trolley should be sited on an even and stable surface The trolley should only be used with appropriate sized cylinders as described in section 1 1 There are no operator serviceable components inside the trolley In the event of problems with the trolley contact BOC Healthcare Refer to Gas Safe with Medical Gases from BOC Healthcare for instructions on the safe use of gas cylinders or alternatively contact your BOC account manager to ask about training 04 User manual ZX trolley 3 Instructions for use 3 2 Orientation of the cylinder on the trolley It is important to ensure that when the cylinder is in place on the trolley there is easy access to the cylinder outlet and also that the live contents gauge ZX and HX cylinders can be easily monitored 3 1 Fitting a full cylinder Position the trolley on an even surface Ensure that the cylinder to be fitted is of the appropriate type and that there is sufficient gas to carry out the intended treatment If the cylinder is new remove the tamper evident seal and the outlet cover Ensure that the rubber strap is disengaged from the tube to ease access A Lift the cylinder onto the cylinder support base Ensure that the cylinder is correctly located to the back of the support base and touching the bumpers on the steel tubes Whilst placing a free hand on the cylinder
5. inder valve or equipment is either lubricated or contaminated with oil or grease This is due to the risk of spontaneous combustion that can occur with high pressure gases in the presence of hydrocarbons Special care is needed with the use of hand creams as these could provide sufficient contamination to the cylinder valve when the cylinder is handled to cause an ignition when the valve is turned on Intended use The ZX trolley is intended to be used throughout the hospital to carry cylinders weighing a maximum of 20 kg full weight and measuring height 930 940 mm and diameter 140 143 mm It is designed for indoor use and equipped with anti static wheels The cylinder trolley is intended for use by porters and clinical staff who have received instruction in the correct use of the trolley Do not use the equipment for any purpose other than its intended application 1 ZX trolley description 1 1 Overview The trolley is designed to carry BOC Healthcare cylinders ZX HX and F or cylinders with the following specifications Maximum cylinder weight 20 kg full weight Height of cylinder 930 940 mm Diameter 140 143 mm The product comprises A steel frame A set of anti static wheels Multiple bumpers Safety locking device to retain the cylinder A demand valve location device 1 2 Features This trolley from BOC Healthcare has a range of innovative features that will make handling of medical gases easier and
6. ions Items Specifications Product name ZX trolley The ZX trolley is manufactured in the UK and assembled by Burnley Beadblasting Ltd Manufactured by Warranty 12 months Dimensions Height 1075 mm Width 330 mm Depth 320 mm Weight Without cylinder 9 8 kg With cylinder typically 20 29 kg Ambient temperature For indoor use only Environmental condition BOC Healthcare is continually developing its product range and reserves the right to alter the above specification without notice For accessories or technical support contact the BOC Customer Service Centre on 08456 447 764 BOC Healthcare Customer Service Centre Priestley Road Worsley Manchester M28 2UT Tel 08456 447 764 Fax 0845 087 0062 bochealthcare uk boc com www bochealthcare co uk The stripe symbol and the letters BOC are registered trade marks of The BOC Group Limited Both BOC Limited and The BOC Group Limited are members of The Linde Group the parent company of which is Linde AG Reproduction without permission is strictly prohibited O BOC Limited 2011 HLC 407935 8AMC 0711 1 5M
7. the steel tube by gently pulling the rubber retaining strap via the handle If necessary you can also place a foot on the foot plate to steady the trolley Remove the cylinder from the cylinder trolley User manual ZX trolley 05 Fig 1 Fig 2 4 Care and maintenance 4 1 Care Remove general dirt with a soft cloth damped with soapy water and rinse with clean water In case of blood or other contamination then disinfect with a suitable disinfectant Ensure the product is cleaned in accordance with the hospital s hygiene plans Do not use any oil based products in the vicinity of an oxygen cylinder Do not use harsh or abrasive cleaning materials as damage may result A Do not immerse in water or any liquid M Do not expose to high temperature e g autoclave 4 2 Storage The trolley is designed for indoor use only 4 3 Maintenance recommendations 4 3 1 Prior to each use Check the following for visible signs of wear or damage Wheels Rubber straps and screws Handle and screws Bumpers on steel tubes and screws If any of the above are worn or damaged remove the equipment from use contact BOC Healthcare and replace any faulty parts with new Spare parts Fig 3 4 3 2 Annually Check the following for visible signs of wear or damage Wheels Rubber straps and screws Handle and screws Bumpers on steel tubes and screws Bumpers underneath foot plate Steel frame If any of the
8. trolley s handle secure the cylinder with the safety locking device by pulling the rubber retaining strap by the handle and fitting the handle groove on the tube see fig 1 If necessary you can also place a foot on the foot plate to Caution Unsecured medical gas cylinders As per the Department of Health Estates and Facilities Alert ref EFA 2010 008 issued 28 July 2010 managers and staff involved in the provision and use of medical gas supplies should ensure that gas cylinders and their trolleys be secured to a wall bracket or other static stable structure to prevent them from toppling 3 3 Removing an empty cylinder Steady the trolley Thereafter always secure the handle with the red safety strap see fig 2 and fig 3 VAN Caution To avoid risk of manual handling injuries or damage to the equipment Ensure that the cylinders are correctly located and that the trolley is placed in a stable and secure place Never lift the trolley when a cylinder empty or full is locked in place Caution Incorrect cylinders Ensure that only cylinders of the correct size and weight are fitted to the trolley Refer to Section 1 1 for guidance Position the trolley on an even surface Ensure that the cylinder is turned off and equipment attached has been removed Remove the red safety strap from the handle Whilst placing a free hand on the cylinder trolley s handle disengage the handle groove from