1. TermiCom SE 15 X7 WWW SYMCOD COM SYMCOD How to install your TermiCom SE 15 X7 The support provided with TermiCom SE 15 X7 permits to fix the unit on a wall or on a table Once fixed the angle of TermiCom SE 15 X7 can be easily adapted to the needs of each user no loosen tighten needed see Y TermiCom fixation handling IMPORTANT The TermiCom should not be cover while ON The back of the TermiCom should not be placed flat on a table or other surfaces the back of the unit is acting as a heat dissipater How to install TermiCom SE 15 X7 desktop position 1 Fix the base support on a horizontal surface the open part of the base in front of the user Be sure to choose a fixed and solid plane surface able to support the weight of the TermiCom 2 Firmly screw the arms to the base support 3 Tighten the nuts inside the base 4 Insert the pivot brackets in the arms 5 Firmly tight the tightening buttons to secure the fixation place the TermiCom at the desired angle IN WARNING fixation amp handlin Choose a fixed and solid plane surface able to support the weight of the TermiCom approximately 30 Pounds 13 6Kg Handle the TermiCom safely in order to avoid any back wound TermiCom SE 15 X7 WWW SYMCOD COM SYMCOD How to install TermiCom SE 15 X7 wall mount position Pivot Tightening brackets button ae Fix the base support on a vertical surface the open part of the base upwards Be sure to c
2. lt gt SYMCOD TermiCom SE 15 X7 User Manual Documentation Version 19 03 2012 WEB site www symcod com E mail support symcod com TermiCom SE 15 X7 Warranty Symcod warrants its products to be free from defects in material and workmanship during one year from the purchase date If a product proves to be defective in material or workmanship during the warranty period Symcod will at its choice repair or replace the product with a similar product Replacement Product or parts may include remanufactured or refurbished parts or components The replacement unit will be covered by the balance of the time remaining on the customer s original limited warranty Symcod provides no warranty for the third party software included with the product or installed by the reseller distributor customer or any other party Warranty does not include Any product on which the serial number has been defaced modified or removed Damage deterioration or malfunction resulting from Accident misuse neglect fire water except for waterproof units lightning or other acts of nature unauthorized product modification or failure to follow instructions supplied with the product Repair or attempted repair by anyone not authorized by Symcod Damage to or loss of any programs data or removable storage media Software or data loss occurring during repair or replacement Any damage of the product due to installation o
3. 120V must be in function for a certain time laps in order to increase the internal temperature that allows the electronic parts to function The TermiCom does not start when I press the power switch 26 TermiCom SE 15 X7 WWW SYMCOD COM SYMCOD Accessories amp options I Figure 16 2 SKT silicone keyboard Figure 14 Sealed rigid casing TermiCom SE 15 side view With keyboard shelf Figure 15 amp 1 Tool balancer 2 Powerscan scanner j u produit Description OPT WTEMP3 Wide temperature option below 0 C environments OPT RFSE15 RF option 802 11b 5 5 dBi antenna 506 01710B Keyboard shelf stainless steel shelf amp bracket See figure 14 518 3E201B 8 pins Bulsin male connectors provided 516 01006 120VAC power cable 12ft for replacement one cable provided 518 3E300B Serial port cap provided 008 01820B SKM Keyboard USB sealed silicone See figure 16 PSC Powerscan scanner industrial need cable rn Standard range See figure 15 2 516 58229 USB cable for Powerscan scanner 508 58001 Tool balancer for scanner See figure 15 1 203 01001 Aluminum touch pen Teflon tip wire amp holder 27 gt TermiCom SE 15 X7 WWW SYMCOD COM SYMCOD Dictionnary Automatic procedure that allows checking or validating the identity of a person or Autologin the identification of any other entity during an electronic exchange to control network access system informat
4. V cleaning It is frequently used in industries where the hygiene standards require equipment cleaning and or sterilization Basic TermiCom SE 15 X7 is provided with a Intel Atom 1 6 GHz processor a 15 tactile color screen LCD TFT resistive and with a solid stainless steel stand which allows desktop or wall mount installation in a few minutes Several inputs and outputs make possible the addition of peripherals such as industrial keyboard bar code scanner or any other peripheral The flash disk included with the basic version can be completely write protected This feature is used to prevent any modification made by the user that could put in danger the application or the operating system The basic operating system included in TermiCom SE 15 X7 is Windows Embedded Standard 7 it is directly installed on the flash disk The Ultra Resistant touch screen is used in environment in which there is particularly abrasive dust Contrary to the standard touch screens that are covered with a polymer this one is covered with a thin layer of tempered glass which makes it much more resistant to the abrasives and even allows it to function with deep scratches Several options are available in order to adapt TermiCom SE 15 X7 to specific needs TermiCom SE 15 X7 provided with the wide temperature option allows the operation of TermiCom SE 15 X7 at below zero temperature You can also use the wireless version of TermiCom SE 15 X7 by including the WiFi 802 11b o
5. charges are at the customer expense and responsibility Please take note that collect package will be refused
6. command line syntax follows fbwfmgr help switch displayconfig overlaydetail enable disable addvolume volumename removevolume volumename 110 addexclusion path removeexclusion path setthreshold threshold setcompression 110 setpreallocation 110 commit volumename filepath restore volumename filepath The following table describes the command line switches Switch Description Displays all configuration information for the write filter including protected volumes list overlay configuration and write through paths The command returns State Indicating current filter state enable or disable and state for next boot Protected Volumes List of protected volumes including the current and next boot state di Compression Current and next boot state for cache compression isplayconfig Threshold Current and next boot values for the overlay cache threshold Write Through Paths Displays a complete list of active and next boot write through paths Pre allocation Status Displays current and next boot status for cache pre allocation Displays detail on the current overlay contents for all protected volumes The command returns Contents Files and folders currently in the overlay for all protected volumes including laydetail aie sizes size of data in overlay and open file handles Memory Usage Total amount of memory being consumed by the overlay enabl
7. failure is integrated in the unit To reinstall WES7 follow these steps 1 Power on the unit 2 Enter BIOS setup by pressing DEL at startup 3 Enter Advanced BIOS Features menu 4 Select Hard Disk Boot Priority and press ENTER 5 Move USB HDD0 to priority 1 6 Press F10 then ENTER to save and quit 7 Follow the steps on screen After the Restore 1 Reboot unit 2 Enter BIOS setup by pressing DEL at startup 3 Move Ch0 M to priority 1 4 Press F10 then ENTER to save and quit 5 The system will complete its installation please wait HyperTerminal The communication and terminal emulation tool HyperTerminal since always offered with the Windows operating systems is no longer available with version 7 As a replacement we installed TeraTerm v4 71 that can be accessed from the Start menu Built in Administrator account By default the Administrator account is disabled in Windows 7 for security purpose In the event that the use of this account would be essential it is possible to enable it that way Access Control Panel Administrative Tools Computer Management In the left pane open Local Users and Groups then select Users In the right pane open Administrator and uncheck Account is disabled box 18 TermiCom SE 15 X7 WWW SYMCOD COM SYMCOD The Administrator account will now be available from the Welcome Screen The default password is Administrator To disable the Administrator account again go back to Com
8. the overlay can impact the speed of the boot process Commits all current level data in the overlay to the protected volume and disables the overlay The overlay is written to the protected volume on the next system boot Committing the overlay can impact the speed of the boot process You can use the live command for both EWF RAM and EWF RAM Reg modes to immediately commit the overlay to the protected volume and disable the overlay without having to reboot the system For example ewfmgr c commitanddisable live Note Live commit and disable is not supported for disk overlay Allows the user to associate an ASCII string with an overlay level This command can be combined with the SetLevel command Disables the overlay on the specified protected volume Enables the write filter so that data that is written to the protected media is cached in the overlays The current overlay level becomes 1 as soon as EWF is started and a new overlay is created at level 1 Clears the current pending command Restores to the prior overlay Same as SetLevel Current Overlay Level 1 Sets the current overlay level to the specified level Valid values for levels are e Current overlay level 1 Starts a new overlay level e 0 Current overlay level Sets the level discarding all data above the specified level e Level Deletes all the data in the specified level and beyond Enables HORM Disables HORM Because EWF manager comma
9. 3 3 2 Product 5 s 8 o E Fr e E E E 3 5 53 2 2 eo 3 z 2 2 2 213 2 3 2 u E 8 5 E 2s s Z TermiCom SE 15 X7 X X X X X 5 C 40 C 100 With Wide Temperature option X X 30 C 40 C 100 With RF option x sc 40 C 100 Maximum temperature IMPORTANT Do not cover while the unit is ON The back of the TermiCom should not be placed flat on a table while the unit is ON Keep the surfaces of the TermiCom free of any material and respect a minimum area of 2 between the back of TermiCom and of any surface in order to allow the dissipation of the internal heat TermiCom SE 15 X7 WWW SYMCOD COM SYMCOD Power TermiCom SE 15 X7 is powered through a 12ft sealed cable which connects to a 120 240VAC power network for the standard models and 120VAC network for units with wide temperature option Power cable is provided with the unit A WARNING powering Before installation please turn off powering source Plug the unit only when the installation is completed A WARNING earth ground Make sure that the TermiCom casing is properly grounded Options description Wide Temperature option The Wide Temperature option allows the TermiCom SE 15 X7 to be functional down to a 30 C temperature If your TermiCom with wide temperature option remained without power at low temperature for a long period of time it is possible that it does not start immediately when you turn the power on T
10. bernate Once Resume Many Environment If you want to make changes or apply updates to your run time image in a Hibernate Once Resume Many HORM environment you must first disable Enhanced Write Filter EWF Because the Boot Environment loads the hibernation file before it reads the pending EWF Manager start commands you must disable EWF and load the system as usual Because Hibernate Once Resume Many environments are supported in EWF RAM and RAM Reg modes you can use the ewfmgr commitanddisable live command which saves the runtime image from the EWF overlay to the persistent image on the system In some cases this is not desirable as it commits the whole cached image To apply a specific set of changes to the system you can disable EWF disable HORM apply changes and re enable HORM To disable EWF in a Hibernate Once Resume Many environment 1 Disable EWF by using the EWF Manager command for example ewfmgr all disable Deactivate HORM by using the EWF manager command for example ewfmgr all deactivatehorm Restart the system After EWF is disabled you can apply updates or install applications to your run time image To re enable Hibernate Once Resume Many see Enable a Hibernate Once Resume Many Environment by Using EWF 23 TermiCom SE 15 X7 WWW SYMCOD COM SYMCOD FBWF FBWF File Based Write Filter protects the specified files folders and or volumes FBWF Manager Command Line Syntax The FBWF Manager
11. e Enables the write filter on the next restart disable Disables the write filter on the next restart addvolume Adds a volume to the protected volume list for next boot removevolume Removes a volume from the protected volume list for next boot addexclusion Adds a write through path to the exclusion list for next boot removeexclusion Removes a write through path from the exclusion list for next boot setthreshold Sets the overlay threshold value for next boot setcompression Sets overlay compression as enabled 1 or disabled 0 for next boot setpreallocation Sets cache pre allocation as enabled 1 or disabled 0 for next boot 24 TermiCom SE 15 X7 WWW SYMCOD COM SYMCOD commit Commits the changes made to the file to the underlying media The volume name can either be a case insensitive volume device name for example Device HarddiskVolume1 or a drive letter for example C or D Note that the name is not the volume label that Windows Explorer displays before the drive letter The file path must be an absolute path starting with Note that the volume must currently be protected Otherwise the error message The system cannot find the drive specified is displayed Discards the changes made to the file that is restores the files to its original contents from the underlying media The volume name can either be a case insensitive volume device name for example Device HarddiskVolume1 or a driv
12. e letter for example C or D Note that the name is not the volume label that Windows Explorer displays before the restore drive letter The file path must be an absolute path starting with It must be a file It is acceptable that the file was deleted in which case it is recovered Note that the volume must currently be protected Otherwise the error message The system cannot find the drive specified is displayed Displays usage and help help switch Displays help information for a specific FBWF Manager switch If no switch is provided the FBWF Manager displays all the configuration information just like the DisplayConfig switch The following table describes the input parameters Input field volumename Full path to a volume 1 Remove exclusion list 0 Preserve exclusion list Full file or directory path including the drive letter Please note that file names are passed to fbwfmgr as a command line argument which means path backslashes and double quotes are interpreted differently For example file name becomes simply file name because the first backslash acts as an escape character To get file name specify file name on the command line threshold Overlay threshold in MB 25 gt TermiCom SE 15 X7 WWW SYMCOD COM SYMCOD Recommendations Ethernet Before proceeding with the wiring installation please consult Ethernet wiring and recommendations TCPIP available at w
13. f the product Causes external to the product such as electric power fluctuations or failure Use of supplies or parts not meeting Symcod specifications Failure of owner to perform periodic product maintenance as stated in documents supplied Any other cause which does not relate to a product defect Damage caused by static Removal installation freight and set up service charges WWW SYMCOD COM Warning A Safety amp reliability page 3 Cleaning pages 4 amp 20 Powering page 7 Earth ground page 7 Fixation amp handling pages 9 amp 10 Sealing pages 12 amp 13 Oxidation page 16 SYMCOD Disclaimer The material on this document is intended for end user distributor and or reseller use Although downloading and printing documents is allowed Symcod will not be responsible for any modification or any other use of any content in the displayed downloaded material Please note that all documents are subject to change without notice and are occasionally revised to specify correct or revise the content or for other purposes Therefore the version displayed on the site may differ from your original printed copy Please contact us if you require assistance Symcod Inc assumes no liability for damage incurred directly or indirectly errors omissions or discrepancies between the device and the manuals or documents supplied Symcod is not responsible for any loss or damage Including data corruption interru
14. he TermiCom will not allow starting as long as the internal operation temperature is not reached The internal power 120V must be in function for a certain time laps in order to increase the internal temperature that allows the electronic parts to function RF option RF option OPT RFSE15 makes possible the use of TermiCom SE 15 X7 without network cable The communication type Wi Fi supports the 802 11a b g A minimum 802 11B Wi Fi infrastructure is required NOTE For installations with multiple antennas it is recommended to configure the antennas access point on various channels like channels 1 6 and 11 This will help avoid interferences problems that can result from antennas that are installed close from one an other Example 1 Installation with two antennas one will be configured at channel 1 and the other at channel 11 Example 2 Installation with three antennas the first will be configured at channel 1 the second at channel 6 and the last at channel 11 Example 3 Installation with antennas the first will be configured at channel 1 the second at channel 6 the third at channel 11 the fourth at channel 1 and the last will be configured at channel 6 gt TermiCom SE 15 X7 WWW SYMCOD COM SYMCOD Desktop or wall mount e t R 4 N id WORA Be Side view Side view Wall mount version Desktop version With or without keyboard shelf Side view Side view With keyboard shelf Without keyboard shelf
15. hoose a fixed and solid plane surface able to support the weight of theTermiCom Firmly screw the arms to the base support Tighten the nuts inside the base Insert the pivot brackets in the arms Firmly tight the tightening buttons to secure the fixation place the TermiCom at the desired angle El ad A WARNING fixation amp handlin Choose a fixed and solid plane surface able to support the weight of the TermiCom approximately 30 Pounds 13 6Kg Handle the TermiCom safely in order to avoid any back wound 10 gt TermiCom SE 15 X7 WWW SYMCOD COM SYMCOD Detailed Specifications TermiCom SE 15 X7 is provided with several ports allowing the connection of various types of peripherals according to needs for example printers electronic scales bar code scanners sensors etc USB1 USB2 USB3 USB4 COM 1 Power supply Ethernet nn 2 COM 2 Figure 1 TermiCom SE 15 X7 bottom view Power connector Figure 2 Power connector The power connector figure 2 is used to plug the TermiCom SE 15 X7 to the 120V or 240V AC power system A 1 ft sealed cable is provided with the unit 11 TermiCom SE 15 X7 WWW SYMCOD COM SYMCOD Ethernet connector Figure 3 Ethernet connector Figure 4 Ethernet connector cable TermiCom SE 15 X7 communicates through an Ethernet 1Gbit connection figure 3 The sealed connector is an RJ 45 standard type To ensure the sealing of the TermiCom see Y sealing you m
16. igure 11 Power switch The power switch figure 11 allows turning on or off the TermiCom SE 15 X7 If your TermiCom was made with the wide temperature option and remained without power at low temperature for a long period of time it is possible that it does not start immediately when you turned on the power The TermiCom will not allow starting as a long as the internal operation temperature is reached The internal power 120V must be in function for a certain time laps in order to increase the internal temperature that allows the electronic parts to function 17 TermiCom SE 15 X7 WWW SYMCOD COM SYMCOD TermiCom SE 15 X7 configuration Operating system The operating system of TermiCom SE 15 X7 is Windows Embedded Standard 7 WES7 which is an embedded version of Windows 7 The Windows Embedded Standard 7 included in the TermiCom SE 15 X7 is specifically designed to work with it and cannot in any case be transferred on another computer This section covers some particularities of our WES7 operating system Excluding that the whole system operates as a Windows 7 system If you don t find in this document the information you are looking for please refer to the Microsoft documentation If a specific configuration or application is working on a Windows 7 system and doesn t work on our WES7 please contact us support symcod com System Restore A USB disk having the unique task of performing a restoration of the system in case of
17. ion processing or software Resistive touch screen Flash disk Can function with finger or object pressure pencil Data storage piece made without any mobile hardware element Can store data over several years without being powered by electricity External device connected to the central processing unit Can ensure the entry or the exit of data Peripheral Computer basic software intended to order the execution of programs by ensuring the work management the input output operations on peripherals the resource allocation to the various processes the access to program libraries and files as well as the accountancy of work Operating system Service and support Support Please use EMAIL for your requests For technical questions hardware and software email at support symcod com e Provide a detail description of the problem and or questions intermittent problem happens when e Please indicate model number and serial number if applicable For all other questions please use symcod symcod com or Symcod Inc at 1171 Notre Dame O Victoriaville Qc G6P 7L1 Phone 1 800 203 9421 1 819 751 0095 Fax 819 751 1292 Return Merchandise Authorisation RMA All return request must be authorized by SYMCOD Inc To do so please refer to the following http www symcod com rma e You will receive a formal confirmation number RMA e The RMA number must be printed on each box e All freight
18. nd line tool to verify that EWF is enabled Ewfmer all If EWF is enabled go to the next step Otherwise enable EWF For example ewfmgr all enable Important You must use the all command because HORM has a requirement that all volumes must either be protected with EWF or be in unmounted state when the Hibernate Once occurs This is to prevent state synchronization problems Each Resume from hibernation expects the entire system to be in exactly the same state as when the Hibernate Once occurred Restart the system Activate HORM by using the EWF Manager command line tool ewfmgr c activateHORM Open applications and start any processes that you want to be running on the system when it resumes from hibernation 22 TermiCom SE 15 X7 WWW SYMCOD COM SYMCOD 7 Hibernate the system shutdown h 8 Restart the system After you restart the system EWF is enabled In the event of an Autologin when Windows is resuming from hibernation it may happen that the user is locked Selecting the user will start the session but there is a way to prevent this inconvenience and make the session start automatically as it is supposed to To do this access Control Panel Power options In the left pane select Require a password on wakeup then select Don t require a password When the HORM is activated changes that do not require to restart the system can be applied Once changes are done simply re hibernate Disable EWF in a Hi
19. nds are executed on the next boot you must reboot the system for a command to take effect Examples The following examples refer to a system on which EWF is configured to protect drive C and on which the EWF partition resides on disk 1 partition 3 The following example shows how to check the EWF status and format ewfmgr c EWF manager displays the following result Protected Volume Configuration Type DISK State DISABLED Boot Command NO CMD 20 u TermiCom SE 15 X7 WWW SYMCOD COM SYMCOD Param 0 Param2 0 Persistent Data Volume ID D2 02 96 49 00 OE 59 96 02 00 00 00 00 00 00 00 Device Name Device HarddiskVolume4 MaxLevels 3 Clump Size 512 CurrentLevel 1 Disk space used for data 0 bytes Disk space used for mapping 0 bytes Memory used for mapping 0 bytes The following example shows how to enable EWF for drive C ewfmer c enable EWF manager displays the Enable command as pending The command does not execute until the next boot EWF manager displays the following result Protected Volume Configuration Type DISK State DISABLED Boot Command NO CMD Param 0 Param2 0 mm Persistent Data Volume ID D202 96 49 00 OE 59 96 02 00 00 00 00 00 00 00 Device Name Device HarddiskVolume4 C MaxLevels 3 Clump Size 512 Current Level 1 Disk space used for data 0 bytes Disk space used for mapping 0 bytes Memory used for mapping 0 bytes Enabling overlay Protected Volume Configurati
20. on Type DISK State DISABLED Boot Command ENABLE Param 0 Param2 0 mm Persistent Data Volume ID D2 02 96 49 00 OE 59 96 02 00 00 00 00 00 00 00 Device Name Device HarddiskV olume4 Max Levels 3 Clump Size 512 Current Level 1 21 TermiCom SE 15 X7 WWW SYMCOD COM SYMCOD The following example shows how to check the status type of the EWF volume ewfmgr EWF manager displays the following result Overlay Configuration Volume Size 2048030208 Segments 8192 Segment Size 249856 Free segments 8192 Max Levels 3 Max Protected Volumes 1 Protected Volumes 1 Overlay volume percent full 0 00 Protected volumes Arc Path Device Harddisk Volume4 Note If EWF is disabled the current level is shown as N A HORM HORM Hibernate Once Resume Many uses the hibernation file hiberfile sys to always start in the same state In the event of a system shutdown whether it is planned manual shutdown or not power failure on the next boot the system will be identical This method will also significantly reduce the boot up time of the computer The size of the hibernation file created will be the same as the RAM Enable a Hibernate Once Resume Many Environment by Using EWF To enable a Hibernate Once Resume Many environment that uses EWF Make sure that your system supports hibernation You can use the Powercfg Command Line Options command line tool to enable hibernation powercfg h on Use the EWF Manager comma
21. ption According to your needs a keyboard shelf with variable slope can be added to your TermiCom IN WARNING cleaning Stainless steel may react to some chemical agents particularly with chlorine Ci component Check with your cleaning product supplier to ensure that the products used for cleaning are suitable and that they will not damage the stainless steel case gt TermiCom SE 15 X7 WWW SYMCOD COM SYMCOD Main characteristics TermiCom SE 15 X7 Color Touch Operating screen LCD System RAM Storage Inputs Outputs Gig DDR2 peripheral nor Wide Temperature option 802 11B Windows Embedded Standard 7 32Gig Flash Disk SSD Hard Disk min 80Gig 1Gbit Ethernet port SVGA port Keyboard shelf Maximum power consumption without Product x 004 01573B 5200 X 004 01574B 5200 i gt 4 gt lt 15 Ultra resistant Resistive Parallel port gt lt ES Serial port O Available Option Basic characteristics TermiCom SE 15 X7 Sealed case stainless steel 304 4 see V cleaning page 5 15in LCD 24 bits LCD 1024 X 768 color resistive touch screen Intel Atom 1 6 GHz processor low power consumption Stainless steel stand wall mount or desktop use OO 0 0 Wireless RF 802 11B option available Basic model without keyboard shelf C gt TermiCom SE 15 X7 WWW SYMCOD COM SYMCOD Environmental specifications g 2
22. ption of operation lost business information lost production etc caused by use non use or misuse of any of the information contained in this document Symcod Inc is not responsible of the content or validity of the links gave as references for other products not manufactured by Symcod Inc Documents include instruction book user guide operating instructions manuals safety precautions instructions data sheets or any other documents supplied by Symcod TermiCom SE 15 X7 WWW SYMCOD COM SYMCOD IMPORTANT Read me first By carrying out the installation and the use of this equipment you accept the rules and limitations described in this document or any other document relating to this product By carrying out the installation and the use of this equipment you are presumed having read all the safety warnings A A WARNING Safety and reliabilit SYMCOD Inc will not be responsible for the use of this equipment for other purpose then data collection This equipment is designed and intended for an industrial and commercial use only The TermiCom SE 15 X7 is not for a residential use TermiCom SE 15 X7 WWW SYMCOD COM SYMCOD TermiCom SE 15 X7 TermiCom SE 15 X7 is a robust sealed computer specially designed for industrial and manufacturing use The Stainless steel casing enables the SE 15 X7 to function even in the most hostile environments TermiCom SE 15 X7 is dust resistant and can be the subject of direct watering see
23. ptor A WARNING Sealing You must use the recommended connectors to insure that the guarantee of sealing of TermiCom SE 15 X7 will apply The connectors must be covered at any time by the special cable connector or by the recommended cap 13 gt TermiCom SE 15 X7 WWW SYMCOD COM SYMCOD Assembly procedure for USB adaptors Figure 7 Important the USB connector must be type A The provided connector can differ from the one showed 14 lt lt TermiCom SE 15 X7 WWW SYMCOD COM SYMCOD Part on the nn BR Q a a Figure 8 Type A USB adaptor Provided connector may differ from the one shown Please refer to figure 7 i pa SON ad To insure a full sealing IP67 install the white sticker around the USB plug B figure 8 covering the four little holes of the over molding Insert the black O Ring around the front face of the USB type A plug This O Ring will ensure the connection sealing Insert the USB cord E figure 8 set into the metallic back shell Insert laterally to the cable the retention spacer C figure 8 this spacer is soft in order to adapt to different shapes of over molding and slide the over molding of the USB type A plug into this retention spacer Insert laterally to the cable the friction ring D figure 8 Screw the part A figure 8 on the USB connector of the TermiCom Plug the USB connector B figure 8 in the TermiCom Make sure that it is well inserted and in the
24. puter Management and simply check Account is disabled box in the Administrator account properties Run as Administrator Certain applications must be run as Administrator to be able to successfully complete every tasks For a single or occasional use of such application the right button of the mouse on the application s icon or its shortcut will give access to this function Tu run an application as administrator all the time use the right button of the mouse on the application s icon and select Properties In the Compatibility tab locate Privilege Level then check Run this program as an administrator box If the box is unavailable to check go in the Shortcut tab click the Advanced button and check Run as administrator box Enhanced Write Filter EWF The Enhanced Write Filter EWF is a built in functionality of the Windows Embedded Standard 7 that allows to write protect the system By default this functionality is disabled The EWF offers 3 methods of protection EWF HORM FBWE The different commands of each method of protection are explained in the following pages from the Microsoft documentation These commands can be run in a Command Prompt window and only as Administrator EWF EWF protects the whole volume Once enabled all the modifications made to the system are effective in RAM only When the system is restarted everything is back to the previous state The EWF is configured in RAM Reg mode The EWF manager con
25. required position Complete the installation by assembling parts C D E and by screwing part A in part E figure 8 The assembly procedure is complete you can unplug the connector if needed 15 TermiCom SE 15 X7 WWW SYMCOD COM SYMCOD Connectors COM1 and COM2 Figure 8 Serial port 1 and 2 TermiCom SE 15 X7 is provided with 2 serial port 8pins sealed see figure 8 The serial ports allow the connection of peripherals such as printers electronic scales and PLC In order to avoid the oxidation of serial ports connector pins see V oxidation the serial ports must be covered at any time If no peripheral is connected the serial port cap must be fixed The cable used for the connection to the serial port his 8 pins male connector at one end and open at the other end provided You must connect the cable of your peripheral to the connector See below for the cable pin out figure 10 Power Out optional RX Receive TX Transmit DTR Data Terminal Ready GND Ground DSR Data Set Ready RTS Request To Send CTS Clear To Send Figure 10 Connector pin out serial port 518 3E201B 8 pins male included A WARNING Oxidation You must use the provided connectors to avoid the oxidation of the serial port pins connectors The connectors must be covered at any time by the special cable connector or by the provided cap 16 TermiCom SE 15 X7 WWW SYMCOD COM SYMCOD Power switch F
26. sole application is used to control Enhanced Write Filter EWF Manager uses the following syntax EWFMGR lt drive letter gt optional options Parameters drive letter Specifies the volume path This is an optional parameter that is used for protected volume configuration mode To view the status of the protected volume specify the drive letter for the protected volume for example ewfmgr c options Specifies the EWF volume boot options The following commands are used to manage protected volume configuration Disable Enable Commit SetLevel Restore Checkpoint Description and Nocmd Remarks The following table shows the Enhanced Write Filter EWF console manager application tool boot commands Boot command Description Displays information about all protected volumes and performs specified commands such as disable enable commit checkpoint and restore on each volume TermiCom SE 15 X7 Checkpoint Commit CommitandDisable Description Disable Enable NoCmd Restore SetLevel ActivateHorm DeactivateHorm 7 gt WWW SYMCOD COM SYMCOD Starts a new overlay level Same as SetLevel Current Overlay Level 1 Commits all current level data in the overlay to the protected volume and resets the current overlay level to 1 The Commit command can be combined with the Disable command to commit and then disable The overlay is written to the protected volume on the next system boot Committing
27. ust install and use the Ethernet cable connector provided to complete the connection see figure 4 If the Ethernet connector is not plugged you must absolutely use the Ethernet connector cap provided see figure 5 to ensure the sealing As any Ethernet equipment that uses cable UTP Cat5 a maximum of 300 feet 91 44 meters of cable is allowed between the hub and or the switch and the TermiCom For more details concerning wiring please download the document WIRING AND EXAMPLE OF CONFIGURATION TCPIP available on www symcod com Figure 5 Ethernet connector cap A WARNING Sealing You must use the recommended connectors to insure that the guarantee of sealing of TermiCom SE 15 X7 will apply The connectors must be covered at any time by the special cable connector or by the recommended cap 12 TermiCom SE 15 X7 WWW SYMCOD COM SYMCOD USB1 USB2 USB3 and USB4 connector Figure 6 USB connectors TermiCom SE 15 X7 has 4 USB connectors see figure 6 1 which allow the connection of various USB peripherals In order to ensure the sealing of TermiCom SE 15 X7 see V sealing USB connectors must be covered at any time If no peripheral is connected the provided caps must be fixed Two USB sealed adapters are also provided see figure 8 and must be used in order to ensure the sealing of the USB peripherals connection The adapters are designed for type A USB connections See next page for the assembly procedure for USB ada
28. ww symcod com TermiCom SE 15 X7 maintenance A crecsine Stainless steel may react to some chemical agents particularly with chlorine Ci component Check with your cleaning product supplier to ensure that the products used for cleaning are suitable and that they will not damage the stainless steel case Certification This equipment has been found compliant to class A Part 15 of FCC Rules These limits are intended to get a reasonable protection against dangerous interferences when the equipment is used in an industrial or commercial environment This equipment emits uses and can generate radiations of radio frequencies and can cause dangerous interference for radio communications if it is not used in accordance with the instruction manual The use of this equipment is not planned for a residential use Troubleshooting Problems Solutions Unplug the 120V power for 10 seconds then plug again If there is no improvement sent a request including the serial number and the detailed description of the problem to technical support at support symcod com I saw the LED lights but there is no screen display If your TermiCom was made with the wide temperature option and remained without power at low temperature for a long period of time it is possible that it does not start immediately when you turned on the power The TermiCom will not allow starting as a long as the internal operation temperature is reached The internal power