Home

H04I-E-01 E5CC-U Data Sheet

image

Contents

1. 850 850 850 Temperature range C 500 0 500 0 500 0 The applicable standards for the input types are as follows K J T E N R S B JIS C 1602 1995 IEC 60584 1 JPt100 JIS C 1604 1989 JIS C 1606 1989 L Fe CuNi DIN 43710 1985 Pt100 JIS C 1604 1997 IEC 60751 U Cu CuNi DIN 43710 1985 PL II According to Platinel Il electromotive force charts from BASF previously Engelhard W W5Re W26Re ASTM E988 1990 Analog input Input type Current Voltage Input SRM 4to20mA 0to20mA 1to5V Oto5V O0to10V specification Usable in the following ranges by scaling Setting range 1999 to 9999 199 9 to 999 9 19 99 to 99 99 or 1 999 to 9 999 Set value 25 26 27 28 29 omnon E5CC U Alarm Outputs Each alarm can be independently set to one of the following 19 alarm types The default is 2 Upper limit see note Auxiliary outputs are allocated for alarms ON delays and OFF delays 0 to 999 s can also be specified Note In the default settings for models with HB or HS alarms alarm 1 is setto a heater alarm HA and the Alarm Type 1 parameter is not displayed To use alarm 1 set the output assignment to alarm 1 Alarm output operation ne Alarm type When alarm valu
2. Watertight Cover Mounting Adapter Y92A 48N Y92F 49 The Mounting Adapter is provided with the Temperature Controller Order this Adapter separately if it becomes lost or damaged 877 79 2 U 67 6 Protective Cover Protective Cover Y92A 48D Note This Protective Cover cannot be used Y92A 48H if the Waterproof Packing is installed This Protective Cover is hard type This Protective Cover is soft type diim tortne mis operaton It is able to operate the controller with using prece eie this cover E5CC U Wiring Socket Front connecting Socket P2CF 11 Eleven M3 5 x 7 5 Terminal Layout Internal Connections Top View sems screws Mounting Holes Two 4 5 dia mounting holes H 4030 2 gt Note Can also be mounted to a DIN track Note 1 A model with finger protection P2CF 11 E is also available 2 You cannot use the P2CF 11 or P2CF 11 E together with the Y92F 45 Back connecting Socket P3GA 11 Eleven M35 Terminal Layout Internal Connections Bottom View 4 5 16 3 6 2 Note 1 Using any other sockets will adversely affect accuracy Use only the specified sockets 2 A Protective Cover for finger protection Y92A 48G is also available 3 You cannot use the P3GA 11 together with the Y92F 45 omnon E5CC E5CC U E5EC E5AC E5DC Operation
3. Setting Levels Diagram This diagram shows all of the setting levels To move to the advanced function setting level and calibration level you must enter passwords Some parameters are not displayed depending on the protect level setting and the conditions of use Control stops when you move from the operation level to the initial setting level Press the Keys for Protect Level at least 1 s Only when Manual Mode was used Used to set protection just before power OFF for operations 0n Press the Key M o foratleast 1 sor Level changes Press the ce o the 8 Key for at i ast 3 s pum least 1 s o Adj Tum M o Manual Control E Press the Key once justment evo i o Level Operation Level Used to change adjustment c ee ety 1 Used for SP alarm Press the Key once PRISES PD ponsin manuall y E y Key for at E values and other basic adjustment sensitivity etc i Cc Eu s while settings and monitoring j O displayed i 4 llM aw 3 3 O o a E fa Press the 9 Key Press the Key D C Key for at least 1 s Q Press the Key Press the Key for j i Q abr M ora sess Monitor Setting Item Level Used to display specified monitor and setting items i Press Key once F Initial Setting Level 1 models with communications only Communications J Setting Level Used to set the input type H Used to set up and other basic set
4. Key to change to another parameter Dimensions Unit mm Controllers E5CC U m 58 6 14 2 p E 58 j H Mounting Adapter Accessory The Setup Tool port is on the top of the Temperature Controller It is used to connect the Temperature Controller to the computer to use the Setup Tool The E58 CIFQ2 USB Serial Conversion Cable is required to make the connection Refer to the instructions that are provided with the USB Serial Conversion Cable for the connection procedure Note Do not leave the USB Serial Conversion Cable connected when you use the Temperature Controller Panel Cutout Mounted Separately Group Mounted 48 x number of units 2 5 4 Recommended panel thickness is 1 to 5 mm 45 05 e Group mounting is not possible in the vertical direction Maintain the specified mounting space between Controllers 60 min T When two or more Controllers are mounted make sure that the surrounding temperature does not exceed the allowable operating temperature specified in the specifications To attach the USB Serial Conversion Cable to the control panel use a panel thickness of 1 to 2 5 mm omnon E5CC U Accessories Order Separately
5. Temperature input Thermocouple K J T E L U N R S B W or PL II Platinum resistance thermometer Pt100 or JPt100 Infrared temperature sensor ES1B 10 to 70 C 60 to 120 C 115 to 165 C or 140 to 260 C Analog input Current input 4 to 20 mA or 0 to 20 mA Voltage input 1 to 5 V to 5 V or 0 to 10 V Input impedance Current input 150 Q max Voltage input 1 MQ min Use a 1 1 connection when connecting the ES2 HB THB Control method ON OFF control or 2 PID control with auto tuning E5CC SPST NO 250 VAC 3 A resistive load electrical life 100 000 operations minimum ap Relay output plicable load 5 V 10 mA y P E5CC U SPDT 250 VAC 3 A resistive load electrical life 100 000 operations minimum applica esa ble load 5 V 10 mA Quipu Voltage output 0 ni 1 H for driving SSR Output voltage 12 VDC 20 PNP max load current 21 mA with short circuit protection circuit Linear current output 4 to 20 mA DC O to 20 mA DC load 500 Q max resolution approx 10 000 E5CC 3 Auxillary eee of outputs E5CC U 1 or 2 depends on model output Output specifications SPST NO relay outputs 250 VAC Models with 1 or 2 outputs 3 A resistive load or Models with 3 P P outputs 2 A resistiveload Electrical life 100 000 operations Minimum applicable load 10 mA at 5 V Number of inputs 2 or 4 depends on model Event input E Contact input ON 1 kQ ma
6. Soak Time atleast 3 s for at least 1 s less than 1 s Work Bit 6 ea i ON Dek Communications xis Protect Level i Setting Level IL 1 Wait Band The time taken to move to the protect level Displayed only for models with x WE 5 D Work Bit 6 can be adjusted by changing the Move to communications Changes are Used with programless communications aFF protect level time setting OFF Delay after a software reset i PMA Move to Protect Level Upload P i MV at Sto Displayed only when a 3 Setting 1 MY R password is set Restricts BCE Protocol Setting Highest n Work Bit 7 C9 moving to protect level f 5E L Switches between EA V Lap Modbus RS Na Upload Restricts displaying and Setting 13 My E MV at PV Error aHPE modifying menus in operation Communications 2 on Work Bit 7 adjustment and manual Unit No Area OFF Delay 5 control levels ie Initial SettinglCommunications Protect Download GPR SP Ramp Set Value This protect level restricts movement to mm Setting 1 E the initial setting communications setting Communications First Address aFF Work Bit 8 and advanced function setting levels Baud Rate ON Delay CompoWaylF pper iod Download ompoWa Ve Setting Change Protect only y i y Setting 13 PRL SPR EIE Protects changes to setups by ze SPRL amp Fall Value eU operating the front panel keys LEN Communications First Address SAME Weine 7 Data Length Lower Word iT co y PF Key Protect md T GL H
7. 5 8 mm E54 CT1 12 0 mm E54 CT3 Adapter Model Y92F 45 Note Use this Adapter when the panehas already been prepared for an E5BL Controller Waterproof Cover Model Y92A 48N Mounting Adapter Model Y92F 49 Note This Mounting Adapter is provded with the Digital Temperature Controller DIN Track Mounting Adapter Model Y92F 52 Sockets for E5CC U Front Covers Type Model Hard Front Cover Y92A 48H Soft Front Cover Y92A 48D Type Model Front connecting Socket P2CF 11 Front connecting Socket with Finger Protection P2CF 11 E Back connecting Socket P3GA 11 ee connecting socket Y92A 48G CX Thermo Support Software Model EST2 2C MV4 Note CX Thermo version 4 5 or higher is required for the E5CC CX Thermo version 4 61 or higher is required for the E5CC U For the system requirements for the CX Thermo refer to information on the EST2 2C MV4 on the OMRON website www ia omron com omnon E5CC U Specifications Ratings Power supply voltage A in model number 100 to 240 VAC 50 60 Hz D in model number 24 VAC 50 60 Hz 24 VDC Operating voltage range 85 to 110 of rated supply voltage Power consumption Models with option selection of 000 5 2 VA max at 100 to 240 VAC and 3 1 VA max at 24 VAC or 1 6 W max at 24 VDC All other models 6 5 VA max at 100 to 240 VAC ad 4 1 VA max at 24 VAC or 2 3 W max a24 VDC Sensor input
8. H174 for range that is given on information on the 332323 Above 9 999 the left the number n trollabl without the decimal conroraoe range point First cycle the power supply If the display remains the same the The control outputs auxiliary A D F A controller must be repaired outputs and transfer outputs turn E711 converter MEE an error In the internal If the display is restored to normal OFF A current ouput will be approx error then a probable cause can be 0 mA and a linear voltage output will external noise affecting the control be approx OV System Check for external noise First cycle the power supply If the display remains the same the The control outputs auxiliary F controller must be repaired outputs and transfer outputs turn c Memory There is an error in the internal If the display is restored to normal OFF A current ouput will be approx C IIt error memory operation f then a probable cause can be 0 mA and a linear voltage output will external noise affecting the control be approx OV System Check for external noise Control continues and operation is normal The error message will appear forthe CEEE This error is displayed when the peak following displays Fr Overcurrent current exceeds 55 0 A 7 Heater Current Value 1 Monitor Heater Current Value 2 Monitor Leakage Current Value 1 Monitor Leakage Current Value 2 Monitor The No 1 display for the following rue parameter flashes in
9. Models with 1 4 to 20 mA DC i Voltage Output Linear Current Relay Output 0 to 20 mA DC 3 for Driving SSR Output Load 500 Q max Duleut Relay output three terminals used i Output 4 Output 1 li E A SPDT 250 VAC 3 A Q 4 C uw resistive load d o 4 omnon E5CC U Isolation Insulation Block Diagrams e E5CC U Models with 2 Auxiliary Outputs Sensor input Voltage output for driving SSR and linear current output Power supply Relay output Auxiliary outputs 1 and 2 LL Reinforced insulation Functional isolation Front panel E5CC U Temperature unit Top View of ESCC Top View of ESCC U Operation indicators No 1 display H Py od PVor specified parameter M No 2 display i 000 SP or specified parameter value p no s or specified parameter value sO 0000 00 8 0000000 0000000 A JUR tee G 1 H en LA Use the Keys to set the 4 parameter N l e Top panel Setup Tool port Press Key once to go to Adjustment Level T Use 8 Key to change the digit default setting Press Key for at least 3 seconds to go to Initial Setting Level I Use the
10. Operation Level LE I or Adjustment Level t P HB or HS If there is a HB or HS alarm the No Heater Current Value 1 Monitor tror alm 1 display will flash in the relevant Heater Current Value 2 Monitor LLI I setting level Leakage Current Value 1 Monitor ICRP Leakage Current Value 2 Monitor PES However control continues and operation is normal will be displayed for the Valve Opening Monitor parameter if any of the following error occurs Motor calibration has not been gt Potentiometer performed Close control The control output is Input Error A OFF or the value that is set for the Position e The wiring of the potentiometer is Check for the above errors MV at PV Error parameter is output proportional incorrect or broken Floating control Operation will be Models Only The potentiometer input value is normal incorrect e g the input is out of range or the potentiometer has failed omnon E5CC E5CC U E5EC E5AC E5DC Operation Parameters The following pages describe the parameters set in each level Pressing the Mode Key at the last parameter in each level returns to the top parameter in that level Some parameters may not be displayed depending on the model and other settings Press the Key 2 Power ON Starting in Manual Mode Manual Control Level Press the C Key for at least 3 s Other than the Auto Manual Switch display Initial S
11. USB Serial Conversion Cable E58 CIFQ2 2 110 k 13 5 15 250 87 ja 1 740 LED RD 250 Bd ee a 3 d c v USB connector type A plug LED PWR Serial connector LED SD Terminal Covers I 48 Terminal Covers E53 COV17 T E r5 E53 COV23 Three Covers provided A 2 38 T UP K Y 3 Terminal Cover TL E53 COV23 4 8 il L 4U U 1 T Loe M B 9 1 S I le Terminal Cover for the P3GA 11 Back connecting Socket Y92A 48G A Twelve 6 4 dia ug C o om Olololo Oo 4o o 34 Was T UP 4T Tx4T 17 48x48 O O O DO oo olg OQJOfojo Nann ae s I 474 Note You can attach the P3GA 11 Back connecting Socket for finger protection Waterproof Packing The Waterproof Packing is provided only with the E5CC Y92S P8 for DIN 48 x 48 Order the Waterproof Packing separately if it becomes lost or damaged The Waterproof Packing can be used to achieve an IP66 degree of protection Deterioration shrinking or hardening of the waterproof packing may occur depending on the operating environment Therefore periodic replacement is recommended to ensure the level of waterproofing specified in IP66 The time for periodic replacement depends on the operating environment Be
12. degree of protection when the Waterproof Packing is used is IP66 To maintain an IP66 degree of protection the Waterproof Packing and the Port Cover for the front panel Setup Tool port must be periodically replaced because they may deteriorate shrink or harden depending on the operating environment The replacement period will vary with the operating environment Check the required period in the actual application Use 3 years or sooner as a guideline If the Waterproof Packing and Port Cover are not periodically replaced waterproof performance may not be maintained If a waterproof structure is not required then the Waterproof Packing does not need to be installed omnon Operating Precautions 1 When using self tuning turn ON power for the load e g heater at the same time as or before supplying power to the Digital Controller If power is turned ON for the Digital Controller before turning ON power for the load self tuning will not be performed properly and optimum control will not be achieved When starting operation after the Digital Temperature Controller has warmed up turn OFF the power and then turn it ON again at the same time as turning ON power for the load Instead of turning the Digital Temperature Controller OFF and ON again switching from STOP mode to RUN mode can also be used 2 Avoid using the Controller in places near a radio television set or wireless installing These devices can cause radi
13. digit max Transfer output accuracy 0 3 FS max Remote SP Input Type 0 2 FS 1 digit max Influence of temperature 2 Thermocouple input R S B W PL Il 1 of PV or 10 C whichever is greater 1 digit max Other thermocouple input 196 of PV or 4 C whichever is greater 1 digit max 3 Platinum resistance thermometer 1 of PV or 2 C whichever is greater 1 digit max Influence of voltage 2 Analog input 1 FS 1 digit max CT input 5 FS 1 digit max Remote SP input 1 FS 1 digit max Input sampling period 50 ms Temperature input 0 1 to 999 9 C or F in units of 0 1 C or F Hysteresis Analog input 0 0196 to 99 9996 FS in units of 0 0196 FS Temperature input 0 1 to 999 9 C or F in units of 0 1 C or F Proportional band P Analog input 0 196 to 999 996 FS in units of 0 196 FS Integral time I 0 to 9999 s in units of 1 s 0 0 to 999 9 s in units of 0 1 s 4 Derivative time D 0 to 9999 s in units of 1 s 0 0 to 999 9 s in units of 0 1 s 4 Proportional band P for cooling ig 096 to 900 9 FS in units of 0 1 FS dis Integral time I for cooling 0 to 9999 s in units of 1 s 0 0 to 999 9 s in units of 0 1 s 4 Derivative time D for cooling 0 to 9999 s in units of 1 s 0 0 to 999 9 s in units of 0 1 s 4 Control period 0 1 0 2 0 5 1 to 99 s in units of 1 s Manual reset value 0 0 to 100 0 in units of 0 1 Alarm setting rang
14. dustor corrosive gas in particular sulfide gas and ammonia gas e Places subject to intense temperature change e Places subject to icing and condensation e Places subject to vibration and large shocks 2 Use and store the product within the rated ambient temperature and humidity Gang mounting two or more Digital Temperature Controllers or mounting Digital Temperature Controllers above each other may cause heat to build up inside the Digital Temperature Controllers which will shorten their service life In such a case use forced cooling by fans or other means of air ventilation to cool down the Digital Temperature Controllers 3 To allow heat to escape do not block the area around the Digital Temperature Controller Do not block the ventilation holes on the Digital Temperature Controller 4 Be sure to wire properly with correct polarity of terminals 5 Use the specified size of crimped terminals M3 width of 5 8 mm or less towire the E5CC E5EC E5AC or E5DC To connect bare wires to the terminal block of the E5CC E5EC E5AC or E5DC use copper braided or solid wires with a gage of AWG24 to AWG 18 equal to a cross sectional area of 0 205 to 0 8231 mm The stripping length is 6 to 8 mm Up to two wires of the same size and type or two crimped terminals can be inserted into a single terminal Use the specified size of crimped terminals M3 5 width of 7 2 mm or less to wire the E5CC U To connect bare wires to the te
15. e Independent heating and Transfer Output cooling PID control auuub Remote SP Input e Changed parameter display None e None ANN e Display brightness setting Serial Communications None mmmmi i This datasheet is provided as a guideline for selecting products Be sure to refer tothe following manuals for application precautions and other information required for operation before attempting to use the product l i E5LIC Digital Temperature Controllers User s Manual Cat No H174 I l E5LIC Digital Temperature Controllers Communications Manual Cat No H175 E a m ERG 5 S E Eom m S wA E5CC U Model Number Legend e Plug in Models E5CC U L Example E5CC RW0AUM 000 0000 amp Model SUE S eund Wu dp em Options Meaning 1 and 2 outputs voltage type type E5CC 48 x 48 mm Control output 1 Control output 2 RW Relay output SPDT None QX Voltage output for driving SSR None CX Linear current output None 0 None 1 1 2 2 one common A 100 to 240 VAC D 24 VAC DC U Plug in model M Universal input HB alarm and HS Communi Event inputs Remote SP Transfer out alarm cations Input put 000 The control output cannot be used as a transfer
16. output List of Models Options Model Model Control output No of auxiliary HB alam and No ot event E Power supply voltage Power supply voltage outputs HS alarm us Communications 100 to 240 VAC 24 VACIDC E5CC RW0AUM 000 E5CC RW0DUM 000 Relay output 1 E5CC RW1AUM 000 E5CC RW1DUM 000 2 E5CC RW2AUM 000 E5CC RW2DUM 000 E5CC QX0AUM 000 E5CC QX0DUM 000 for a SS 1 m E5CC QX1AUM 000 E5CC QX1DUM 000 2 E5CC QX2AUM 000 E5CC QX2DUM 000 E5CC CX0AUM 000 E5CC CX0DUM 000 uu current 1 E5CC CX1AUM 000 E5CC CX1DUM 000 2 E5CC CX2AUM 000 E5CC CX2DUM 000 Heating and Cooling Control eG Using Heating and Cooling Control Control Output Assignment An auxiliary output is used as the cooling control output 2 Control If PID control is used you can set PID control separately for heating and cooling This allows you to handle control systems with different heating and cooling response characteristics omnon E5CC U Optional Products Order Separately USB Serial Conversion Cable Model E58 CIFQ2 Terminal Covers for E5CC Model E53 COV17 E53 COV23 Note The E53 COV10 cannot be used Refer to page 14 for the mounted dimensions Waterproof Packing Model Y92S P8 Note The Waterproof Packing is provided only with E5CC Controllers The E5CC U cannot be waterproofed even if the Waterproof Packing is attached Current Transformers CTs Hole diameter Model
17. sure to confirm this point at your site Consider three years a rough standard The Waterproof Packing does not need to be attached if a waterproof structure is not required The E5CC U cannot be waterproofed even if the Waterproof Packing is attached omnon E5CC U Adapter Y92F 45 Note 1 Use this Adapter when the Front Panel has already been prepared for the E5B 2 Only black is available 3 You cannot use the E58 CIFQ2 USB Serial Conversion Cable if you use the Y92F 45 Adapter To use the USB Serial Conversion Cable to make the settings do so before you mount the Temperature Controller in the panel Fixture Accessory 4 7 76 69 6 to 77 6 F 72 x 72 gt Panel 1 to 8 mm Mounting Adapter Y92F 30 Accessory 48 x 48 2 2 4 7 62 8 To back of the E5CC DIN Track Mounting Adapter Y92F 52 Note This Adapter cannot be used together with the Terminal Cover Remove the Terminal Cover to use the Adapter This Adapter is used to mount the E5CC to a DIN Track If you use the Adapter there is no need for a plate to mount in the panel or to drill mounting holes in the panel omnon E5CC U
18. tothe Digital Temperature Controller ON or OFF while the USB Serial Conversion Cable is connected The Digital Temperature Controller may malfunction 27 Make sure that the indicators on the USB Serial Conversion Cable are operating properly Depending on the application conditions deterioration in the connectors and cable may be accelerated and normal communications may become impossible Perform periodic inspection and replacement 28 Connectors may be damaged if they are inserted with excessive force When connecting a connector always make sure that it is oriented correctly Do not force the connector ifit does not connect smoothly 29 Noise may enter on the USB Serial Conversion Cable possibly causing equipment malfunctions Do not leave the USB Serial Conversion Cable connected constantly to the equipment 30 For the E5DC when you attach the Main Unit to the Erminal Unit make sure that the hooks on the Main Unit are securely inserted into the Terminal Unit 31 For the E5CC U when you attach the Main Unit to the socket make sure that the hooks on the socket are securely inserted into the Main Unit 32 Install the DIN Track vertically to the ground 33 For the E5DC always turn OFF the power supply before connecting the Main Unit to or disconnecting the Main Unit from the Terminal Unit and never touch nor apply shock to the terminals or electronic components When connecting or disconnecting the Main Unit do not allow the electr
19. upper limit The sensor is not wired correctly or input type settings cycle the If an input error is assigned to a The sensor is not wired power supply control output or auxiliary output the If the display remains the same output will turn ON when the input Control Range replace the Digital Temperature error occurs ERR Inputerror Temperature resistance Controller The error message will appear in the thermometer or thermocouple input If the display is restored to normal display for the PV SP Lower Limit 20 C to SP Upper then the probable cause is external Limit 20 C noise affecting the control system Note 1 The heating and cooling SP Lower Limit 40 F to SP Upper Check for external noise control outputs will turn Limit 40 F OFF ESIB input Note For a temperature resistance 2 When the manual MV MV Same as specified input range thermometer the input is at stop or MV at error is Analog input considered disconnected if set the control output is Scaling range 5 to 105 the A B or B line is broken determined by the set value This is not an error It is displayed when the c AM Below 1 999 control range is wider Control continues and operation is than the display The value will appear in the display ge and the PV Display exceeds the display for the PV range range The PV is Refer to the E5LIC Digital exceeded displaved for the Temperature Controllers User s payeo fore Manual Cat No
20. 10 C to 50 C 2 Mounting Method Standard mounting lt gt Bottom 1 Note Average Operating Temperature Refer to the process temperature of the Unit mounted to a control panel and connected to peripheral devices on condition that the Unit is in stable operation sensor input type K is selected for the Unit the positive and negative thermocouple input terminals of the Unit are short circuited and the ambient temperature is stable Should the Unit malfunction during the guarantee period OMRON shall repair the Unit or replace any parts of the Unit at the expense of OMRON omnon MEMO Terms and Conditions of Sale omnon Ti Qa 9 10 11 12 Offer Acceptance These terms and conditions these Terms are deemed part of all quotes agreements purchase orders acknowledgments price lists catalogs manuals brochures and other documents whether electronic or in writing relating to the sale of products or services collectively the Products by Omron Electronics LLC and its subsidiary companies Omron Omron objects to any terms or conditions proposed in Buyers purchase order or other documents which are inconsistent with or in addition to these Terms Prices Payment Terms All prices stated are current subject to change with out notice by Omron Omron reserves the right to incr
21. 8 EMI EN61326 Radiated Interference Electromagnetic Field Strength EN 55011 Group 1 class A Noise Terminal Voltage EN 55011 Group 1 class A EMS EN 61326 EMC ESD Immunity EN 61000 4 2 Electromagnetic Field Immunity EN 61000 4 3 Burst Noise Immunity EN 61000 4 4 Conducted Disturbance Immunity EN 61000 4 6 Surge Immunity EN 61000 4 5 Voltage Dip Interrupting Immunity EN 61000 4 11 1 The indication accuracy of K thermocouples in the 200 to 1300 C range T and N thermocouples at a temperature of 100 C max and U and L thermocouples at any temperatures is 2 C 1 digit max The indication accuracy of the B thermocouple at a temperature of 400 C max is not specified The indication accuracy of B thermocouples at a temperature of 400 to 800 C is 3 C max The indication accuracy of the R and S thermocouples at a temperature of 200 C max is 3 C 1 digit max The indication accuracy of W thermocouples is 0 3 of PV or 3 C whichever is greater 1 digit max The indication accuracy of PL II thermocouples is 0 3 of PV or 2 C whichever is greater 1 digit max 2 Ambient temperature 10 C to 23 C to 55 C Voltage range 15 to 10 of rated voltage 3 K thermocouple at 100 C max 10 C max 4 The unit is determined by the setting of the Integral Derivative Time Unit parameter 5 External communications RS 485 and USB serial conversion cable communications can be used at the same time 6 The E5CC U plug in mode
22. AC Drives Motion Controllers amp Encoders Temperature amp Process Controllers Single and Multi loop Controllers Sensors amp Vision Proximity Sensors Photoelectric Sensors Fiber Optic Sensors Amplified Photomicrosensors Measurement Sensors Ultrasonic Sensors Vision Sensors Industrial Components RFID Code Readers Relays Pushbuttons amp Indicators Limit and Basic Switches Timers Counters Metering Devices Power Supplies Safety Laser Scanners Safety Mats Edges and Bumpers Programmable Safety Controllers Light Curtains Safety Relays Safety Interlock Switches Cat No HO4I E 01 01 14 Note Specifications are subject to change 2014 Omron Electronics LLC Printed in U S A Printed on recycled paper e
23. AGES LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS WHETHER SUCH CLAIM IS BASED IN CONTRACT WARRANTY NEGLIGENCE OR STRICT LIABILITY Further in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted Indemnities Buyer shall indemnify and hold harmless Omron Companies and their employees from and against all liabilities losses claims costs and expenses including attorney s fees and expenses related to any claim inves tigation litigation or proceeding whether or not Omron is a party which arises or is alleged to arise from Buyer s acts or omissions under these Terms or in any way with respect to the Products Without limiting the foregoing Buyer at its own expense shall indemnify and hold harmless Omron and defend or set tle any action brought against such Companies to the extent based on a claim that any Product made to Buyer specifications infringed intellectual property rights of another party Property Confidentiality Any intellectual property in the Products is the exclu Sive property of Omron Companies and Buyer shall not attempt to duplicate it in any way without the written permission of Omron Notwithstanding any charges to Buyer for engineering or tooling all engineering and tooling shall remain the exclusive property of Omron All information and materials supplied by Omron to Buyer relating to the Products are confide
24. Digital Temperature Controller E5CC U 48 x 48 mm Large White PV Display That s Easier to Read Mule CE Easy to Use from Model Selection to LISTED Setup and Operation A Complete Range of I O Capacities Functions and Performance Handles More Applications The white PV display with a height of 15 2 mm improves visibility High speed sampling at 50 ms prie Models are available with up to 2 auxiliary outputs to cover a wide range of applications Refer to your OMRON website for the most recent information on e EBCC Short body with depth of only 60 mm applicable salety standards Set up the Controller without wiring the power supply by connecting to the computer with a Communications Conversion A Refer to Safety Precautions Cable sold separately Setup is easy with the CX Thermo sold separately Main I O Functions Sensor Input E5CC U Universal input e Thermocouple eS e Pt nummum age ij e Analog current voltage dM S R Dual displays PV SV 4 digit displays Control Output 1 e Relay output e Voltage output for driving SSR e Linear current output Indication Accuracy e Thermocouple input 0 3 of PV e Pt input 0 2 of PV e Analog input 0 2 of FS Sampling Period e 50 ms Control Output 2 e None Auxiliary Outputs mum None Event Inputs 1 None PF shift Key 02 pene e Temperature status display e Simple programming
25. ION WARNING or DANGER precautions for which there is no specified symbol This symbolis also used as the alerting symbol but shall not be used in this meaning on the product Used for general mandatory action precautions for which there is no specified symbol A CAUTION Do not touch the terminals while power is being supplied Doing so may occasionally result in minor injury due to electric shock o eoe Electric shock may occur Do not touch any cables or connectors with wet hands Electric shock fire or malfunction may occasionally occur Do not allow metal objects conductors cuttings from installation work or moisture to enter the Digital Temperature Controller or the Setup Tool port or ports Attach the cover to the front panel Setup Tool port whenever you are not using it to prevent foreign objects from entering the port 2e gt Do not use the Digital Temperature Controller where subject to flammable or explosive gas Otherwise minor injury from explosion may occasionally occur Not doing so may occasionally result in fire Do not allow dirt or other foreign objects to enter the Setup Tool port or ports or between the pins on the connectors on the Setup Tool cable 21 omnon Minor electric shock or fire may occasionally occur Do not use any cables that are damaged Never disassemble modify or repair the product or touch any of the internal parts Minor electric shock fire or m
26. MV Upper Limit s Communications Receive Data 1000 M or aatan Stop Bits Wait Time SP Slo F UF B Changed Parameters Only 5o pe Ye E le 3 Tt imit Ce ol L MV Lower Limit PARE Y Communications Communications PMG i Parameter Mask Enable EVEN Parity Node Number SP Offset 1121 Displayed only when a 3 5N parameter mask is set ce Ye OHNE Send Data Wait PRL P Password to Move to Time Protect Loval 1 When the PF Setting parameter is set to A M Password setting 8 2 When the PF Setting parameter is set to PFDP 3 Used with component communications omnon E5CC E5CC U E5EC E5AC E5DC 25 Monitor Setting Monitor Setting Monitor Setting Q Monitor Setting PF Monitor Setting ni Item Display 1 Item Display 2 Item Display 3 Item Display 4 Item Display 5 Note The monitor setting items to be displayed is set in the Monitor Setting Item 1 to 5 parameters advanced function setting level Press the Key for at least 1 s Automatic Display Return Time Parameter Initialization SP Tracking Number of Multi SP PV Dead Band Points Display Brightness Manual MV Limit Enable SP Ramp Time Unit Direct Setting of Peatier Proportional Standby Sequence Reset m Pu ar in Py
27. Please consult with your Omron s representative at any time to confirm actual specifications of purchased Product Errors and Omissions Information presented by Omron Companies has been checked and is believed to be accurate however no responsibility is assumed for clerical typographical or proofreading errors or omissions OMRON AUTOMATION amp SAFETY OMRON AUTOMATION AND SAFETY THE AMERICAS HEADQUARTERS Hoffman Estates IL USA 847 843 7900 800 556 6766 e www omron247 com OMRON CANADA INC HEAD OFFICE Toronto ON Canada 416 286 6465 866 986 6766 www omron247 com OMRON ELECTRONICS DE MEXICO HEAD OFFICE M xico DF 52 55 59 01 43 00 01 800 226 6766 mela omron com OMRON ELECTRONICS DE MEXICO SALES OFFICE Apodaca N L 52 81 11 56 99 20 01 800 226 6766 mela omron com OMRON ELETR NICA DO BRASIL LTDA HEAD OFFICE Sao Paulo SP Brasil 55 11 2101 6300 www omron com br OMRON ARGENTINA SALES OFFICE Cono Sur 54 11 4783 5300 OMRON CHILE SALES OFFICE Santiago 56 9 9917 3920 OTHER OMRON LATIN AMERICA SALES 54 11 4783 5300 OMRON EUROPE B V Wegalaan 67 69 NL 2132 JD Hoofddorp The Netherlands 31 0 23 568 13 00 e www industrial omron eu Authorized Distributor Automation Control Systems Machine Automation Controllers MAC Programmable Controllers PLC Operator interfaces HMI Distributed I O Software Drives amp Motion Controls Servo amp
28. Products or oth erwise of any intellectual property right c Buyer Remedy Omron s sole obli gation hereunder shall be at Omron s election to i replace in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof the non complying Product ii repair the non complying Product or iii repay or credit Buyer an amount equal to the purchase price of the non complying Product provided that in no event shall Omron be responsi ble for warranty repair indemnity or any other claims or expenses regarding the Products unless Omron s analysis confirms that the Products were prop erly handled stored installed and maintained and not subject to contamina tion abuse misuse or inappropriate modification Return of any Products by Buyer must be approved in writing by Omron before shipment Omron Compa nies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components circuits system assemblies or any other materials or substances or environ ments Any advice recommendations or information given orally or in writing are not to be construed as an amendment or addition to the above warranty See http www omron247 com or contact your Omron representative for pub lished information Limitation on Liability Etc OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAM
29. R p PV Rate of Change ggj Calculation Period Heating Cooling arr Tuning Method x fai eu Pr zz Control Output 1 Signal 1 ce PRL L Move to Protect Level GMP Minimum Output APSE Control Output 2 Signal 3 ee 40 ON OFF Band se Cold Junction PF Settin ERSE Transfer Output Signal LIL Compensation j D aN Method 9 e un 2p m amp ruJ 9 5 uu ST Stable Range 2 amp d R un c oO lt 2 amp i Integral Derivative PV SP No 1 Display Time Unit PV SP No 2 Display 5Pd 5 Selection AT Calculated Gain Soak Time Unit o Wu or an MV Display Selection AT Hysteresis AL P Alarm SP Selection PV Decimal Point Display Remote SP Input Limit Cycle MV Amplitude Mi GE MV at Stop and Error Addition ce a ri C Close Floatin Input Digital Filter HM Auto Manual Select Remote SP Enable PV Status Display LFL g PUTO Addition Function Flat sE n Y T D L Motor Calibration Moving evel ede OUR MANE Manual Output Method Remote SP y SE SM Status Display LAL H Upper Limit
30. alfunction may occasionally occur CAUTION Risk of Fire and Electric Shock a This product is UL listed 1 as Open Type Process Control Equipment It must be mounted in an enclosure that does not allow fire to escape externally b More than one disconnect switch may be required to de energize the equipment before servicing the product c Signal inputs are SELV limited energy 2 d Caution To reduce the risk of fire or electric shock do not interconnect the outputs of different Class 2 circuits 3 gt OO If the output relays are used past their life expectancy contact fusing or burning may occasionally occur Always consider the application conditions and use the output relays within their rated load and electrical life expectancy The life expectancy of output relays varies considerably with the output load and switching conditions gt Even if you replace only the Main Unit of the E5DC check the condition of the Terminal Unit If corroded terminals are used contact failure in the terminals may cause the temperature inside the Digital Controller to increase possibly resulting in fire If the terminals are corroded replace the Terminal Unit as well gt Tighten the terminal screws to the rated torque of between 0 43 and 0 58 Nem 4 Loose screws may occasionally result in fire Set the parameters of the product so that they are suitable for the system being controlled If they are not suitable unexpected op
31. arr Function oFF ai ic Y MV Display MONT Remote SP Display Refresh Mat Travel Time i RANE Manual MV Initial Value PERES dREF Period 30 Q Y Irm L LCT Cooling Output oR Extraction of Square LLH Minimum ON Time L Root Enable 82 E5DC only aFF Y Em Move to Advanced Function Move to Calibration HMa Setting Level HSS Displayed when initial Isetting communications co protect is set to 0 Move by setting password 169 omnon E5CC E5CC U E5EC E5AC E5DC Safety Precautions Be sure to read the precautions for all ESCC E5EC E5AC E5DC models in the website at http www ia omron com Warning Indications Indicates a potentially hazardous situation which if not avoided may CAUTION result in minor or moderate injury or in property damage Supplementary comments on what to do or avoid doing to use the product safely Precautions for Safe Use Supplementary comments on what to Precautions for do or avoid doing to prevent failure to Correct Use operate malfunction or undesirable effect on product performance Meaning of Product Safety Symbols Used to warn of the risk of electric shock under specific conditions Used for general prohibitions for which there is no specific symbol Used to indicate prohibition when there isa risk of minor injury from electrical shock or other source if the product is disassembled Used for general CAUT
32. d lower limit hysteresis overlaps Case 3 Always OFF Set value 5 Upper and lower limit with standby sequence Always OFF when the upper limit and lower limit hysteresis overlaps Refer to the E5 C Digital Temperature Controllers User s Manual Cat No H174 for information on the operation of the standby sequence Refer to the E5 C Digital Temperature Controllers User s Manual Cat No H174 for information on the loop burnout alarm LBA Refer to the E5 C Digital Temperature Controllers User s Manual Cat No H174 for information on the PV change rate alarm When heating cooling control is performed the MV absolute upper limit alarm functions only for the heating operation and the MV absolute lower limit alarm functions only for the cooling operation This value is displayed only when a remote SP input is used It functions in both Local SP Mode and Remote SP Mode Remote SP input is supported only for the E5CC omnon E5CC U Characteristics E5CC Thermocouple 0 3 of PV or 1 C whichever is greater 1 digit max 1 Platinum resistance thermometer 0 2 of PV or 0 8 C whichever is greater 1 digit Indication accuracy Analog input 10 296 FS 1 digit max at the ambient temperature of 23 C ERU 5 FS 1 digit max Thermocouple 1 of PV or 2 C whichever is greater 1 digit max 1 Platinum resistance thermometer 0 2 of PV or 0 8 C whichever is greater 1 digit Analog input 0 2 FS 1
33. e I3 LE C Monitor LowerLimit d tuni owerLimit 3 GE ST Self tuning on 3 2 pr amp N For input type of Hh e ae L Proportional Band Work Bit 2 temperature standard DD 8 Cooling control or PID E Pree LER Leakage Current 1 Alarm 3 vl ce i 00 Monitor Valued lt z PE IN Program Pattern 1 FO 1 Leakage Current 1 Pas s 8 SFF When assigning PID or LLN I Monitor amp E Integral Time Work Bit 3 Vie control exu 19 ON OFF i Key ON Dalay 1 Ff Leakage Current 2 MamWde E output ie Vie LL Re Monitor UpperLimit t 4 a i T HS Alarm 1 E d Derivative Time 5 LF Control Period Heating L 2 H E 1 etre Work Bit 3 co cm zu Set the ON OFF E OFF Delay PRSE Program Star Mamae 3 output cycle Lower Limit ce ross Control Period Cooling iT Leakage Current2 r LL Re Monitor E db E Work Bit 4 oo ON Delay Soak Time Remain d MV Monitor Ye Ve eating amp RE DirecuReverse 0 Hg HS Alarm 2 p Manual Reset Value a On Ce DIET pO OF R Clear the offset during Noe ej BRR s00 sanin of P or PD OFF Delay R 5 eee MV Monitor 1 Cooling co RUN g Ye z FILE Alarm 1 Type H6 Hysteresis Heating DE ie 2 fork Bit 10 Eat y uem ON Delay RL 1 omia Set either of Mae Opening Ve Hysteresis settings a these neo Alarm 1 E H6 Hysteresis Cooling parameters Hysteresis Work Bit 5 U a OFF Delay ye Press the and Keys for Press the and Keys Press the Key Ga HI
34. e 1999 to 9999 decimal point position depends on input type Thermocouple 0 1 C Q max 100 Qmax Indusdeehsiprd puro TS Ue Platinum resistance thermometer 0 1 C Q max 10 Q max Insulation resistance 20 MQ min at 500 VDC Dielectric strength 3 000 VAC 50 60 Hz for 1 min between terminals of different charge Vibration Malfunction 10 to 55 Hz 20 m s for 10 min each in X Y and Z directions Resistance 10 to 55 Hz 20 m s for 2 hrs each in X Y and Z directions Shock Malfunction 100 m s 3 times each in X Y and Z directions Resistance 300 m s 3 times each in X Y and Z directions Weight E5CC Controller Approx 120 g Mounting Bracket Approx 10 g E5CC U Controller Approx 100 g Mounting Bracket Approx 10 g E5CC Front panel IP66 Rear case IP20 Terminals IPOO Degree of protection E5CC U Front panel IP50 Rear case IP20 Terminals IPOO Memory protection Non volatile memory number of writes 1 000 000 times E5CC CX Thermo version 4 5 or higher Setup Tool E5CC U CX Thermo version 4 61 or higher E5CC E5CC U top panel An E58 CIFQ2 USB Serial Conversion Cable is used to connect to a USB Setup Tool port port on the computer 5 Standard Approved standards UL 61010 1 6 KOSHA certified some models 7 Korean Radio Waves Act Act 10564 Palast Conformed standards EN 61010 1 IEC 61010 1 Pollution level 2 overcurrent category II Lloyd s standards
35. e X When alarm value X Description of function is positive is negative 0 Alarm function OFF Output OFF No alarm Set the upward deviation in the set point for the alarm upper 4 Upper and lower limit 1 mesi ubi i limit H and the lower deviation inthe set point for the alarm pp OFF SP Py lower limit L The alarm is ON when the PV is outside this deviation range 2 exclu m Set the upward deviation in the set point by setting the alarm default UPPer limit ON OE ey Value X The alarm is ON when the PV is higher than the z m SP SP by the deviation or more hyena ee Set the downward deviation in the set point by setting the 3 Lower limit oe BU xs ev alarm value X The alarm is ON when the PV is lower than d SP the SP by the deviation or more Set the upward deviation in the set point for the alarm upper 4 Upper and lower limit on e 3 limit H and the lower deviation inthe set point for the alarm range 1 OFF SP PV lower limit L The alarm is ON when the PV is inside this de viation range 5 Upper and lower limit on L H je 4 A standby sequence is added to the upper and lower limit with standby sequence 1 pg OFF SP PV alarm 1 6 limi Xie X 6 ones with standby oe kw Bee E A standby sequence is added to the upper limit alarm 2 6 SP SP anni P X e X le 7 ple with standby ped py o py A standby sequence is added to the lower limit alarm 3 6 SP SP Absolute value upper lim on MEE ON XI The alar
36. ease or decrease prices on any unshipped portions of outstanding orders Payments for Products are due net 30 days unless otherwise stated in the invoice Discounts Cash discounts if any will apply only on the net amount of invoices sent to Buyer after deducting transportation charges taxes and duties and will be allowed only if i the invoice is paid according to Omron s payment terms and ii Buyer has no past due amounts Interest Omron at its option may charge Buyer 1 1 2 interest per month or the maximum legal rate whichever is less on any balance not paid within the stated terms Orders Omron will accept no order less than 200 net billing Governmental Approvals Buyer shall be responsible for and shall bear all costs involved in obtaining any government approvals required for the impor tation or sale of the Products Taxes All taxes duties and other governmental charges other than general real property and income taxes including any interest or penalties thereon imposed directly or indirectly on Omron or required to be collected directly or indirectly by Omron for the manufacture production sale delivery importa tion consumption or use of the Products sold hereunder including customs duties and sales excise use turnover and license taxes shall be charged to and remitted by Buyer to Omron Financial If the financial position of Buyer at any time becomes unsatisfactory to Omron Omron reserves the right to stop shi
37. en two or more Digital Temperature Controllers are mounted horizontally close to each other or vertically next to one another the internal temperature will increase due to heat radiated by the Digital Temperature Controllers and the service life will decrease In such a case use forced cooling by fans or other means of air ventilation to cool down the Digital Temperature Controllers When providing forced cooling however be careful not to cool down the terminals sections alone to avoid measurement errors Measurement Accuracy 1 When extending or connecting the thermocouple lead wire be sure to use compensating wires that match the thermocouple types 2 When extending or connecting the lead wire of the platinum resistance thermometer be sure to use wires that have low resistance and keep the resistance of the three lead wires the same 3 Mount the product so that it is horizontally level 4 Ifthe measurement accuracy is low check to see if input shift has been set correctly Waterproofing Not applicable to the E5CC U E5DC The degree of protection is as shown below Sections without any specification on their degree of protection or those with IPLIO are not waterproof Front panel IP66 Rear case IP20 Terminal section IPOO When waterproofing is required insert the Waterproof Packing on the backside of the front panel Keep the Port Cover on the front panel Setup Tool port of the EBEC E5AC securely closed The
38. eration may occasionally result in property damage or accidents A malfunction in the product may occasionally make control operations impossible or prevent alarm outputs resulting in property damage To maintain safety in the event of malfunction of the product take appropriate safety measures such as installing a monitoring device on a separate line eoec 1 E5CC E5EC E5AC and E5DC Controllers that were shipped through November 2013 are UL recognized 2 An SELV separated extra low voltage system is one with a power supply that has double or reinforced insulationbetween the primary and the secondary circuits and has an output voltage of 30 V r m s max and 42 4 V peak max or 60 VDC max 3 A class 2 circuit is one tested and certified by UL as having the current and voltage of the secondary output restricted to specific levels 4 The specified torque is 0 5 N m for the E5CC U E5CC E5CC U E5EC E5AC E5DC Precauitions for Safe Use Be sure to observe the following precautions to prevent malfunction or adverse affects on the performance or functionality of the product Not doing so may occasionally result in faulty operation 1 This product is specifically designed for indoor use only Do not use this product in the following places e Places directly subject to heat radiated from heating equipment e Places subject to splashing liquid or oil atmosphere e Places subject to direct sunlight e Places subject to
39. etting Level k Press the Key for less than 1 s Starting in Press the KP Key 2 Automatic Mode Press the Key or the F5 Key for at least Press the Key for at least 1 s Press the Key for at least 1 s Input Type Adjustment Press the Key less than 1 s Level Scaling Upper Limit caling Upper Limit Press the Key less than 1 s Adj
40. from Omron to Buyer provided that Omron shall retain a security inter est in the Products until the full purchase price is paid d Delivery and shipping dates are estimates only and e Omron will package Products as it deems proper for protection against nor mal handling and extra charges apply to special conditions Claims Any claim by Buyer against Omron for shortage or damage to the Products occurring before delivery to the carrier must be presented in writing to Omron within 30 days of receipt of shipment and include the original trans portation bill signed by the carrier noting that the carrier received the Products from Omron in the condition claimed Warranties a Exclusive Warranty Omron s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron or such other period expressed in writing by Omron Omron disclaims all other warranties express or implied b Limitations OMRON MAKES NO WARRANTY OR REPRESENTATION EXPRESS OR IMPLIED ABOUT NON INFRINGEMENT MERCHANTABIL 14 15 16 17 18 ITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
41. l is certified for UL listing only when used together with the OMRON P2CF 11 or P2CF 11 E Socket The P3GA 11 is not certified for UL listing 7 Access the following website for information on certified models http Avww ia omron com support models index html 8 Refer to information on maritime standards in Shipping Standards on page 56 for compliance with Lloyd s Standards The E5CC U is scheduled to obtain certification in January 2014 omnon E5CC U USB Serial Conversion Cable Applicable OS Windows XP Vista or 7 CX Thermo version 4 5 or higher Version 4 61 or Applicable software Higher is required for the ESCC U Electrical Life Expectancy Curve for Relays Reference Values Applicable models E5LIC T Series E5_IC Series and E5CB Series 500 USB interface standard Conforms to USB Specification 2 0 E 300 DTE speed 38400 bps amp Computer USB type A plug 5 400 connector i Digital Temperature Controller x P Special serial connector 2 a o Power supply Bus power Supplied from USB host controller Power supply voltage 5 VDC Current consumption 450 mA max 30 4 740 2 VDC 19 Output voltage Supplied from USB Serial Conversion Cable to 5 the Digital Temperature Controller E5CC 250 mA max 3 250 VAC 30 VDC i istive load Output current Supplied from USB Serial Conversion Cab
42. le to al pac the Digital Temperature Controller Ambient operating 0 1 2 3 4 5 6 0 to 55 C with no condensation or icing temperature a z Switching current A PUN EE 10 to 80 Storage temperature 20 to 60 C with no condensation or icing Storage humidity 10 to 80 Altitude 2 000 m max Weight Approx 120 g Windows is a registered trademark of Microsoft Corporation in the United States and or other countries Use a high power port for the USB port Note A driver must be installed on the computer Refer to the Instruction Manual included with the Cable for the installation procedure External Connections The E5CC U is set for a K type thermocouple input type ESCC HOOOUM 000 5 by default An input error 5 7 will occur if the input Control output 1 type setting does not agree with the temperature sensor Check the input type A Auxiliary outputs 1 and 2 Relay output 250 VAC 3 A resistive load Control output 1 6 emm uxiliary outpu ve Auxiliary output 2 Pt ina si E A 9 Control output cooling side mA v TC i S B gt L Jj gt 2 b out O 0 Input power supply 4 Sensor temperature analog input 100 to 240 VAC Control output 1 24 VACIDC no polarity Voltage output for driving SSR Contr l a tput 1 G 12 VDC 21 mA i ox CX RW Linear current output i Models with 1 Models with 1
43. m will turn ON ifthe process value is larger than the 8 it ORE Fey OFF en ey alarm value X regardless of the set point ou ON x ON X The alarm will turn ON if the process value is smaller thanthe 3 Absolute value lower limit or PV OFF m Pv alarm value X regardless of the set point Absolute value upper lim ov Xx ON E A standby sequence is added to the absolute value upper 19 it with standby sequence OFF L Fy ORE en er limit alarm 8 6 Absolute value lower limit on x gt ON UEM A standby sequence is added to the absolute value lower n with standby sequence OFF LI OFF my limit alarm 9 6 12 LBA alarm 1 type only 7 13 PV change rate alarm 8 SP absolute value ON at ON E This alarm type turns ON the alarm when the set point SP i upper limit alarm OFF SPa COE inum is higher than the alarm value X SP absolute value ON mx ON I This alarm type turns ON the alarm when the set point SP 19 lower limit alarm OFF mu ORE m is lower than the alarm value X Standard Control Standard Control o I x Xx gt ae MV pes m 16 MV absolute value This alarm type turns ON the alarm when the manipulated upper limit alarm 9 Heating Cooling Heating Cooling variable MV is higher than the alarm value X Control Heating MV Control Heating MV ON I X OFF o MW Always ON Standard Control Standard Control ON xX ON Axe OFF MV OFF 7 MV 17 MV absolute value Heatina Coolin This alarm t
44. nd equipment that could present a risk to life or prop erty Please know and observe all prohibitions of use applicable to this Prod uct NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS AND THAT THE OMRON S PRODUCT IS PROP ERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM Programmable Products Omron Companies shall not be responsible for the user s programming of a programmable Product or any consequence thereof Performance Data Data presented in Omron Company websites catalogs and other materials is provided as a guide for the user in determining suitabil ity and does not constitute a warranty It may represent the result of Omron s test conditions and the user must correlate it to actual application require ments Actual performance is subject to the Omron s Warranty and Limitations of Liability Change in Specifications Product specifications and accessories may be changed at any time based on improvements and other reasons It is our prac tice to change part numbers when published ratings or features are changed or when significant construction changes are made However some specifica tions of the Product may be changed without any notice When in doubt spe cial part numbers may be assigned to fix or establish key specifications for your application
45. ntial and proprietary and Buyer shall limit distribution thereof to its trusted employees and strictly prevent disclosure to any third party Export Controls Buyer shall comply with all applicable laws regulations and licenses regarding i export of products or information iii sale of products to forbidden or other proscribed persons and ii disclosure to non citizens of regulated technology or information Miscellaneous a Waiver No failure or delay by Omron in exercising any right and no course of dealing between Buyer and Omron shall operate as a waiver of rights by Omron b Assignment Buyer may not assign its rights hereunder without Omron s written consent c Law These Terms are governed by the law of the jurisdiction of the home office of the Omron company from which Buyer is purchasing the Products without regard to conflict of law princi ples d Amendment These Terms constitute the entire agreement between Buyer and Omron relating to the Products and no provision may be changed or waived unless in writing signed by the parties e Severability If any provi sion hereof is rendered ineffective or invalid such provision shall not invalidate any other provision f Setoff Buyer shall have no right to set off any amounts against the amount owing in respect of this invoice g Definitions As used herein including means including without limitation and Omron Compa nies or similar words mean Omron Cor
46. nto consideration when performing control operations 17 The number of non volatile memory write operations is limited Therefore use RAM write mode when frequently overwriting data during communications or other operations 18 Use suitable tools when taking the Digital Temperature Temperature Controller apart for disposal Sharp parts inside the Digital Temperature Controller may cause injury 19 For compliance with Lloyd s standards the E5CC E5CC U E5EC and E5AC must be installed under the conditions that are specified in Shipping Standards 20 Do not connect cables to both the front Setup Tool port and the top panel or bottom panel Setup Tool port at the same time The Digital Controller may be damaged or may malfunction 21 Do not place heavy object on the Conversion Cable bend the cable past its natural bending radius or pull on the cable with undue force 22 Do not disconnect the Communications Conversion Cable or the USB Serial Conversion Cable while communications are in progress Damage or malfunction may occur 23 Do not touch the external power supply terminals or other metal parts on the Digital Temperature Controller 24 Refer to the ES IC Digital Temperature Controllers User s Manual Cat No H174 for information on the communications distances and cables for the ESL IC 25 Do not bend the communications cables past their natural bending radius Do not pull on the communications cables 26 Do not turn the power supply
47. o disturbances which adversely affect the performance of the Controller Others 1 Do not Connect or disconnect the Conversion Cable connector repeatedly over a short period of time The computer may malfunction 2 After connecting the Conversion Cable to the computer check the COM port number before starting communications The computer requires time to recognize the cable connection This delay does not indicate failure 3 Do not connect the Conversion Cable through a USB hub Doing so may damage the Conversion Cable 4 Do not use an extension cable to extend the Conversion Cable length when connecting to the computer Doing so may damage the Conversion Cable Mounting Mounting to a Panel E5CC There are two models of Terminal Covers that you can use with the E5CC Terminal Cover E53 COV17 Sold separately Adapter Terminal Cover E53 COV23 c Water Proof Packing Panel E5CC U For the Wiring Socket for the E5CC U purchase the P2CF 11 or PG3A 11 separately 1 For waterproof mounting waterproof packing must be installed on the Controller Waterproofing is not possible when group mounting several Controllers Waterproof packing is not necessary when there is no need for the waterproofing function The E5CC U cannot be waterproofed even if the Waterproof Packing is inserted 2 Insert the E5CC E5CC U into the mounting hole in the panel 3 Push the adapter from the terminals up to
48. onic components to touch the case omnon E5CC E5CC U E5EC E5AC E5DC Shipping Standards The E5CC E5CC U E5EC and E5AC comply with Lloyd s standards When applying the standards the following installation requirements must be met in the application Application Conditions Installation Location The E5CC E5CC U E5EC and E5AC comply with installation category ENV1 and ENV2 of Lloyd s standards Therefore they must be installed in a location equipped with air conditioning They cannot be used on the bridge or decks or in a location subject to strong vibration Precautions for Correct Use Service Life 1 Use the product within the following temperature and humidity ranges Temperature 10 to 55 C with no icing or condensation Humidity 25 to 85 If the product is installed inside a control board the ambient temperature must be kept to under55 C including the temperature around the product 2 The service life of electronic devices like Digital Temperature Controllers is determined not only by the number of times the relay is switched but also by the service life of internal electronic components Component service life is affected by the ambient temperature the higher the temperature the shorter the service life and the lower the temperature the longer the service life Therefore the service life can be extended by lowering the temperature of the Digital Temperature Controller 3 Wh
49. pments or require satisfactory security or payment in advance If Buyer fails to make payment or otherwise comply with these Terms or any related agreement Omron may without liabil ity and in addition to other remedies cancel any unshipped portion of Prod ucts sold hereunder and stop any Products in transit until Buyer pays all amounts including amounts payable hereunder whether or not then due which are owing to it by Buyer Buyer shall in any event remain liable for all unpaid accounts Cancellation Etc Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Omron against all related costs or expenses Force Majeure Omron shall not be liable for any delay or failure in delivery resulting from causes beyond its control including earthquakes fires floods strikes or other labor disputes shortage of labor or materials accidents to machinery acts of sabotage riots delay in or lack of transportation or the requirements of any government authority Shipping Delivery Unless otherwise expressly agreed in writing by Omron a Shipments shall be by a carrier selected by Omron Omron will not drop ship except in break down situations b Such carrier shall act as the agent of Buyer and delivery to such carrier shall constitute delivery to Buyer c All sales and shipments of Products shall be FOB shipping point unless oth erwise stated in writing by Omron at which point title and risk of loss shall pass
50. poration and any direct or indirect subsidiary or affiliate thereof Certain Precautions on Specifications and Use 1 Suitability of Use Omron Companies shall not be responsible for conformity with any standards codes or regulations which apply to the combination of the Product in the Buyer s application or use of the Product At Buyer s request Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product This information by itself is not sufficient for a complete determination of the suitability of the Prod uct in combination with the end product machine system or other application or use Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer s application product or system Buyer shall take application responsibility in all cases but the following is a non exhaustive list of applications for which particular attention must be given i Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this document ii Use in consumer products or any use in significant quantities iii Energy control systems combustion systems railroad systems aviation Systems medical equipment amusement machines vehicles safety equip ment and installations subject to separate industry or government regulations iv Systems machines a
51. rminal block of the E5CC U use copper braided or solid wires with a gage of AWG24 to AWG14 equal to a cross sectional area of 0 205 to 2 081 mm The stripping length is 5 to 6 mm Up to two wires of the same size and type or two crimped terminals can be inserted into a single terminal 6 Do not wire the terminals that are not used 7 Use a commercial power supply forthe power supply voltage input to a Digital Temperature Controller with AC input specifications Do not use the output from an inverter as the power supply Depending on the output characteristics of the inverter temperature increases in the Digital Temperature Controller may cause smoke or fire damage even if the inverter has a specified output frequency of 50 60 Hz 8 To avoid inductive noise keep thewiring for the product s terminal block away from power cables carry high voltages or large currents Also do not wire power lines together with or parallel to product wiring Using shielded cables and using separate conduits or ducts is recommended Attach a surge suppressor or noise filter to peripheral devices that generate noise in particular motors transformers solenoids magnetic coils or other equipment that have an inductance component When a noise filter is used at the power supply first check the voltage or current and attach the noise filter as close as possible to the product Allow as much space as possible between the product and devices that genera
52. te powerful high frequencies high frequency welders high frequency sewing machines etc or surge 9 Use this product within the rated load and power supply 10 Make sure that the rated voltage is attained within two seconds of turning ON the power using aswitch or relay contact Fthe voltage is applied gradually the power may not be reset or output malfunctions may occur 11 Make sure that the Digital Temperature Controller has 30 minutes or more to warm up after turning ON the power before starting actual control operations to ensure the correct temperature display 12 When executing self tuning with E5_IC turn ON power to the load e g heater atthe same time as or before supplying power to the product If power is turned ON to the product before turning ON power to the load self tuning will not be performed properly and optimum control will not be achieved 13 A switch or circuit breaker must be provided close to the product The switch or circuit breaker must be within easy reach of the operator and must be marked as a disconnecting means for this unit 14 Use a soft and dry cloth to clean the product carefully Do not use organic solvent such as paint thinner benzine or alcohol to clean the product 15 Design the system e g control panel considering the 2 seconds of delay that the product s output to be set after power ON 16 The output may turn OFFwhen you move to the initial setting level Take this i
53. the panel and temporarily fasten the E5CC 4 Tighten the two fastening screws on the adapter Alternately tighten the two screws little by little to maintain a balance Tighten the screws to a torque of 0 29 to 0 39 N m E5CC E5CC U E5EC E5AC E5DC Precautions when Wiring e Separate input leads and power lines in order to prevent external noise e Use a shielded AWG24 to AWG18 cross sectional area of 0 205 to 0 8231 mm twisted pair cable Use a shielded AWG24 to AWG14 cross sectional area of 0 205 to 2 081 mm twisted pair cable for the E5CC U The stripping length is 6 to 8 mm for the E5CC E5EC E5AC or E5DC and 5 to 6 mm for the E5CC U e Use crimp terminals when wiring the terminals Use the suitable wiring material and crimp tools for crimp terminals e Tighten the terminal screws to a torque of 0 43 to 0 58 N m The specified torque is 0 5 N m for the E5CC U e For the E5CC E5EC E5AC or E5DC use the following types of crimp terminals for M3 screws 5 8 mm max TO sem max e For the E5CC U use the following types of crimp terminals for M3 5 screws AUG 7 2 mm max EN O 7 2 mm max as Three year Guarantee Period of Guarantee The guarantee period of the Unit is three years starting from the date the Unit is shipped from the factory Scope of Guarantee The Unit is guaranteed under the t following operating conditions Top 1 Average Operating Temperature see note
54. tings Press the Key once communications Release protection and then enter the password 7169 for the Ritoy Move Press the Key for at least 1 s TO to Advanced Setting oO Level parameter e z Q Advanced Function O Setting Level D Used to set application functions Enter the password 1201 for the Move to Calibration Level parameter Calibration Level 1 To use a key procedure to move to Manual Control Level set the Auto Manual Select Addition parameter to ON and set the PF Setting parameter to A Auto Manual 2 The No 1 display will flash when the keys are pressed for 1 s or longer 3 Set the PF Setting parameter to PF dP monitor setting items omnon Error Displays Troubleshooting E5CC E5CC U E5EC E5AC E5DC When an error occurs the No 1 display or No 2 display shows the error code Take necessary measure according to the error code referring the following table Display Name Meaning Action Operation After the error occurs and it is The input value exceeded the control Check the wiring for input to be sure displayed the alarm output will range it is wired correctly not broken and operate as if the upper limit was The input type is not set correctly not shorted Also check the input exceeded The sensor is disconnected or short type It will also operate as if transfer circuited If there are no problems in the wiring output exceeded the
55. ustment Level Display Displayed only g5 Process Value Alarm Value aM Adit once when y 1 Set Point 1 Upper Limit Scaling Lower Limit eneung L NS Process Value Input MV Change Rate gt adjustment level an ES Limit ce zm Alarm Val le es roS alle fale Decimal Point 3 1 FIL AT Execute Cancel LNRE Procese Value Slope Position For input type of analog SFE 1000 Coefficient Proportional e Dead Band p m ButerManust Switch mm g ie 17 PID control only 2 Temperature Unit es Added when Value2 lt 7 2 CE EMM a ions F5 5 Remote SP Input Shift Open Close Press the Eee eR pent E For input type of aFF Dn Hysteresis Key MES 5 temperature co for at Set Alarm Value 3 n 4 ce V co least 3 s Point Selection Upper Limit SP Upper Limit GPMd SP Mode RSPRE Remote SP Input Extraction of 2 5 ite inga Slope Coefficient Square Root 5 Low cut Point Limit the set point l ie Remote SP Monitor Md v GL L SP Lower Limit 2 E LL ower Limit Ke 2 Proportional Band 200 Cr EE io Work EJ c 5 a um ES GP M Set Point During Alarm 3 we ie 1 SP Ramp Value3 E NEL PID ON OFF Heater Burnout Integral Time z aNaF Hb i co P Detection 1 Work Bit 1 ce A ce J OFF Delay 2 ce 9 Ve PID settings Ce lien an ro 5 TUE Standard or EET oo 3 5 L Heating Cooling Ero oao curona g Derivative Time 5 SENd zz Value Monitor 40 Work Bit 2 ce 42 an ON Delay TE g fester Curent 2 Value Alarm Value 5 y c
56. with no condensation or icing for 3 year warranty 10 to 50 C with no condensation or icing Ambient operating humidity 25 to 85 Storage temperature 25 to 65 C with no condensation or icing Altitude 2 000 m max Recommended fuse T2A 250 VAC time lag low shut off capacity Installation environment Installation Category II Pollution Class 2 IEC 61010 1 compliant You cannot select a relay output or linear current output for control output 2 Note There are no optional functions for the E5CC U Refer to Model Number Legend and List of Models on page 4 omnon E5CC U Input Ranges Thermocouple Platinum Resistance Thermometer Universal inputs Sensor Platinum resistance Thermocouple Infrared temperature type thermometer sensor Sensor specifica Pt100 JPt100 K J T ESEI U lels le Tw leal See ee ee eke tion 2300 2300 1800 1700 1600 1500 1400 1300 1200 1100 1000 900 800 E 700 600 600 500 400 0 400 400 0 400 400 0 a i 2 120 165 200 100 0 100 0 90 100 100 0 0 0 0 0 0 0 0 0 0 0 0 100 20 0 100 20 0 100 200 200 199 9 199 9 200 200 199 9 200 200 199 9 200 Setvalue O 1 2 31 1415 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Shaded settings are the default settings 1800 1700 1700 1300 1300 1300
57. x OFF 100 kQ min P Fus Input Non contact input ON Residual voltage 1 5 V max OFF Leakage current 0 1 mA max Current flow Approx 7 mA per contact Transfer Number of outputs 1 only on models with a transfer output output Output specifications Contact output 4 to 20 mA DC load 500 Q max resolution approx 10 000 P P Linear voltage output 1 to 5 VDC load 1 kO max resolution Approx 10 000 Setting method Digital setting using front panel keys Remote SP input Current input 4 to 20 mA DC or 0 to 20 mA DC input impedance 150 O max Voltage input 1 to 5 V 0 to 5 V or 0 to 10 V input impedance 1 MQ min Indication method 11 segment digital display and individual indicators Character height PV 15 2 mm SV 7 1 mm Multi SP Up to eight set points SPO to SP7 can be saved and selected using event inputs key operations or serial communications Bank switching None Other functions Manual output heating cooling control loop burnout alarm SP ramp other alarm functions heater burnout HB alarm including SSR failure HS alarm 40 AT 100 AT MV limiter input digital filter self tuning robust tuning PV input shift run stop protection functions extraction of square root MV change rate limit simple calculations temperature status display simple programming moving average of input value and display brightness setting Ambient operating temperature 10 to 55 C
58. ype turns ON the alarm when the manipulated lower limit alarm 9 C i n C g MV Heating Cooling variable MV is lower than the alarm value X ontrol Cooling MV Control Cooling MV ON X gt OFF MV Always ON 18 RSP absolute value ON rm ON p This alarm type turns ON the alarm when the remote SP upper limit alarm 10 OFF 3 Asp OFF v S RSP is higher than the alarm value X RSP absolute value mx xem This alarm type turns ON the alarm when the remote SP 19 ae yp lower limit alarm 10 OFF OFF RS D 0 RSP is lower than the alarm value X omnon E5CC U 4 2 3 With set values 1 4 and 5 the upper and lower limit values can be set independently for each alarm type and are expressed as L and H Set value 1 Upper and lower limit alarm Case 1 Case 2 Case 3 Always ON a H lt 0 L lt 0 L H SP SPL H H SP L H lt 0 L gt 0 H gt 0 L lt 0 eei lt 0 0 IH lt ILI IH gt IL H LSP H 2 L H gt 0 L lt 0 SPH L IHI lt L Set value 4 Upper and lower limit range Case 1 Case 2 Case 3 Always OFF H lt 0 L lt 0 L H SP SPL H H SP L H 0 L0 H 0 L lt 0 ZLLLLLE 5e IHI lt ILI IHI gt ILI H LSP IHI 2 ILI H gt 0 L lt 0 SPH L IHI lt ILI 4 b 6 7 8 9 10 Set value 5 Upper and lower limit with standby sequence For Upper and Lower Limit Alarm Described Above 2 Case 1 and 2 Always OFF when the upper limit an