KETOP T100 KVC - KETOP Virtual Channel Tutorial V 1.0

image

Contents

1. On the server side the data on the display show that the connection has been established see following screen During the operation on the KETOP all modifications are transmitted to the server such as actuation of handwheel override potentiometer and membrane keys By entering on the server you can call the menu with all available commands By entering different letters or numbers and pressing Enter on the server you can check and modify the state of the KETOP on the server side roanzavertine E alus fur the tereentavertion min 11358 ME 7 For example e Enter i to check the set time of the screensaver e Enter I and then 15 to actively set the screensaver time e Enter i to check the set time of the screensaver once again as a confirmation e Enter g to check the set background lighting g Finish the program To finish the program on the KETOP side double click on the icon in the task bar and select Disconnect On the server enter Q Tutorial V 1 0 KEBA 2002 13 Important Notes for Locating Errors KETOP T100 6 Important Notes for Locating Errors TCP IP Connection server side To check the TCP IP settings open a DOS window b Start gt Programs gt Accessories gt Command Prompt a ipconfig This command enables checking the IP settings of your own computer Depending on the configuration
2. Preparation of KETOP Since the KETOP Virtual Channel software is already installed on the KETOP T100 the device must only be configured correctly Hardware configuration Unless the device has already been operated with the Ethernet connection check and if necessary adjust the cable connections in the device b Open the cable entrance area on the rear side of the KETOP T100 Plug the RJ45 connector of the connecting cable into the socket provided for Ethernet b Connect your network or your network card of the PC to the Ethernet out socket of the connecting box using a hub or a cross link cable Software configuration On the Ketop the settings for the network card must be adapted to the configuration of the server Plug in the device and turn it on gt Call the network settings via Start Control Panel Network Onboard Ethernet P Set DHCP or the fixed IP address Example with fixed IP address Onboard Ethernet Settings x IP Address Name Servers An IP address can be Obtain an IP address via DHCP automatically assigned to this computer If your network Specify an IP address does not automatically assign 192 168 181 54 addresses ask your network 1 ER 237 192 168 181 794 administrator for an address bnet Mask 255 255 255 0 and then type it in the space su provided Default Gateway 192 168 181 1 gt Modifications of the network setti
3. of your computer the following data may appear c gt ipconfig Windows 2000 IP Configuration Ethernet adapter Local Area Connection Connection specific DNS Suffix IP Address 4 t 192 168 181 54 Subnet Mask i 4 x w uc 299429529940 Default Gateway b ping This command enables checking the connection to another computer or the existence of another computer Depending on the configuration of your computer the following data may appear C ping 192 168 181 54 Pinging 192 168 181 54 with 32 bytes of data Reply from 192 168 181 54 bytes 32 time lt 10ms L 128 Reply from 192 168 181 54 bytes 32 time lt 10ms L 128 Reply from 192 168 181 54 bytes 32 time lt 10ms L 128 Reply from 192 168 181 54 bytes 32 time lt 10ms L 128 Ping statistics for 192 168 181 54 Packets Sent 4 Received 4 Lost 0 5 loss Approximate round trip times in milli seconds Minimum Oms Maximum Oms Average Oms If the message Request timed out appears instead the selected computer does not exist or cannot be reached The message Destination host unreachable appears if the target address is out of the valid range of the Subnet Mask 14 Tutorial V 1 0 KEBA 2002 KVC KETOP Virtual Channel Important Notes for Locating Errors The target address may only differ from the own address at the positions to which 0 is assigned in the Subnet Mask bitwise comparison TCP IP Connection KETOP sid
4. KEBAMACHINEAND ROBOTCONTROL KETOP T100 KVC KETOP Virtual Channel Tutorial V 1 0 KE DK Q 7 lt S show Notes on This Manual At various points in this manual you will see notes and precautionary warnings regarding possible hazards The meaning of the symbols used is explained below Failure to observe safety precautions identified by this symbol could result in personal injury and or damage to machinery and equipment This symbol reminds you of the possible consequences of touching electrostatically sensitive components Notice Notes on use of equipment and useful practical tips are identified by the Notice symbol Notices do not contain any information that draws attention to potentially dangerous or harmful functions KEBA 2002 Specifications are subject to change due to further technical developments Details presented may be subject to correction All rights reserved Document version V 1 0 Filename ketop t100 kvc tutorial en doc last saving on 12 3 2002 document number KEBA AG Postfach 111 Gewerbepark Urfahr A 4041 Linz Tel 43 732 70 90 0 Fax 4443 732 73 09 10 E Mail keba keba co at www keba com KEBA GmbH Ulmer StraBe 123 D 73037 G ppingen Tel 49 7161 97 41 0 Fax 49 7161 97 41 40 KEBA Corp 100 West Big Beaver Road Troy MI 48084 Tel 1 248 526 0561 Fax 1 248 526 0562 E Mail schr us keba com KETOP T100 Co
5. e On the KETOP the program vxUtil in the Windows directory can be used to check the network settings and the connection to the server e With Info symbol I the current settings of the network adapter under CELAN 1 can be called e With Ping symbol 2 tennis rackets the server host can be requested to respond For that purpose the IP address of the server must be entered Tutorial V 1 0 15 KEBA 2002 Important Notes for Locating Errors KETOP T100 16 Tutorial V 1 0 KEBA 2002
6. er or Advanced Server with activated terminal services e Processor Pentium min 300 MHz recommended e Memory 64 MB RAM 128 MB RAM recommended e Hard disk 1 GB free e Ethernet card 8 Tutorial V 1 0 KEBA 2002 KVC KETOP Virtual Channel Prerequisites PC standalone Part Designation M No 1 e MS Windows 98 NT 2000 e Prozessor Pentium min 90 MHz recommended e Memory 64 MB RAM e Hard disk 5 MB free e Ethernet card KEBA Components Part Designation M No K1 e g KETOP T100 VGA KETOP T100 008 xxx with Virtual Channel already installed K2 Connection Cable e g 50 m KETOP TT 050 K3 Connection Box KETOP CB 111 K4 Intermediate Cable e g 4 m KETOP IC 040 Network Part Designation M No e Direct connection cross linked cable between server and KETOP or via a hub e 10MBit Tutorial V 1 0 9 KEBA 2002 Installation of KETOP Virtual Channel on PC KETOP T100 3 Installation of KETOP Virtual Channel on PC This tutorial assumes that the computer and the network are already configured correctly Therefore it only describes the KVC specific configurations gt For the installation only the downloaded files must be unpacked with Winzip and stored in the requested path on the PC e g c Programs KVC 10 Tutorial V 1 0 KEBA 2002 KVC KETOP Virtual Channel Preparation of KETOP 4
7. ngs must be stored in the Registry by calling Registry Backup via Start Programs To activate the modifications i e to initialize the network controller with the new data reboot the KETOP Tutorial V 1 0 KEBA 2002 11 Establishing the Connection KETOP T100 5 Establishing the Connection Once the KVC server software is installed on the PC and the connection between the KETOP and the PC is established the connection of the KVC clients with the server can be established gt Start the test application TestKVCServer exe in the directory KVC b Start the KVC server by entering 1 The following message appears gt Start the KVC client on the KETOP by calling the KETOP Virtual Channel via Start Programs KETOP In the first moments the connection cannot be established because no address has been specified for the server yet and the message Error cannot connect to server appears P Click on the icon for KCV mistart Baws E In the window that follows you can enter the IP address of the KVC server Config K C Server IP Address 192 168 181 180 Connect Disconnect b After entering the IP address select Connect to establish the connection 12 Tutorial V 1 0 KEBA 2002 KVC KETOP Virtual Channel Establishing the Connection In case of a successful connection the colour of the icon in the Start bar will change to green
8. ntents History Modification Modified Description Author from to pages 150202 First Release Tutorial V 1 0 3 KEBA 2002 General Information KETOP T100 4 Tutorial V 1 0 KEBA 2002 KETOP T100 Contents Contents 1 General InformatiOn ie o ad aD Ss aaa dr nS ance pa 7 2 Prerequisites eene a tees RE RS TT 8 Required Components iii 8 PC if combined with TSC iii 8 PO standal te rise ied deb eec de auld eas PURO EYE heads 9 KEBA Comporients bis eisi tutt ee eel e E da eee Ht esp line 9 uo x 9 3 Installation of KETOP Virtual Channel on PC eese nana ananasas 10 4 Preparation of KETOBD a sa i asi ia i in E ii ca sr ii canne gene nr iais 11 Hardware configuration a R A 11 Software configuration sise 11 5 Establishing the Connection ss 12 6 Important Notes for Locating Errors ss 14 TCP IP Connection server side su 14 Wise 14 egeo 14 TCP IP Connection KETOP side ndr eee eet teer ev De taber ss 15 Tutorial V 1 0 5 KEBA 2002 General Information KETOP T100 6 Tutorial V 1 0 KEBA 2002 KVC KETOP Virtual Channel General Information 1 General Information The KETOP Vi
9. rtual Channel KVC is used as extension of a Terminal Server Client TSC application see Tutorial KETOP T100 TSC Information that cannot be transmitted at all or cannot be transmitted in time via the TSC such as values from the handwheel the override potentiometer membrane keys etc can be transmitted to the server via the KVC Since the KVC is executed entirely independently of the TSC the TSC functions can also be used as extension of other applications The application described here should only demonstrate the function of the KVC and should not be used during real operation For that purpose the functions of the KVC should be integrated in a separate C program see User s Manual KETOP T100 p 57ff Tutorial V 1 0 KEBA 2002 Prerequisites KETOP T100 2 Prerequisites Required Components _K3 K4 ONLY TERMINAL IN RS422 OUT ETHERNET OUT B L TME TT TRE 7 ND FN IM 1 AN IE p Overview of required components The numbering of the components in this drawing is the same in the following tables PC if combined with TSC Part Designation M No 1 e NT4 0 Terminal Server Edition or e Windows 2000 Serv