Home

Dimplex FX20IPX4 Downflow Instructions - Issue 3

image

Contents

1. 8 Fix the product inplace by inserting and tightening the third screw Fix mains cable securly using the products cable clamp 9 Set the selector switch to provide either 1kW or 2kW output 10 Replace the top cover and screws Se The appliance is now ready for use and the electricity supply can be reinstated Fig 3 FX20IPX4 Wiring Diagram FX20IPX4 Controls sedar The heater is fitted with a pull cord operated ON OFF switch a thermostat a cut out and a thermal fuse link The heater has an internal adjustable thermostat which can be adjusted by installer i e the top cover has to be removed see Fig 4 for controls details miemaiadnsai with cover removed Temp range 18 C thermostat knob 32 C Fig 4 Cleaning and User Maintenance WARNING BEFORE UNDERTAKING CLEANING OR MAINTENANCE WORK ON THE APPLIANCE DISCONNECT THE ELECTRICITY SUPPLY BY SWITCHING OFF AT THE ADJACENT DOUBLE POLE SWITCH The outside can be cleaned by wiping it over with a soft damp cloth and then dried Do not use abrasive cleaning powders or furniture polish as this can damage the surface finish Ensure that dust or fluff does not accumulate inside the heater as this could lead to overheating of the element Use a vacuum cleaner to remove any fluff which does accumulate Recycling For electrical products sold within the European Community At the end of the electrical products useful life it shoul
2. not less than 300mm below the ceiling or other projecting surface It must also be not less than 250mm from an adjacent projecting surface For most effective heating performance the heater should be mounted at the minimum height i e 1800mm above the floor Care must be taken to ensure that when in use the air stream is not obstructed by a high shelf or cabinet The appliance is secured to the wall with three screws two through keyhole slots 1 and 3 and one through a hole 2 to hold the appliance firmly in position see Fig 2 1 Remove the top cover from the appliance by removing the two screws securing the top cover and hinging it back 2 Mark the position of the two keyhole slots 1 and 3 see Fig 2 for dimensions on the wall and drill and plug for the two suitable screws 3 Partially insert the two screws then hang the appliance on these screws Mark the position of the third hole this is used to secure the product 4 Remove the appliance and drill and plug for the third screw Remount the appliance on the wall using the two keyhole slots Feed the supply cord or wires through the inlet at the top rear of the appliance leaving sufficient free length to connect to the terminal block 7 Make electrical connections to the terminal block ensuring that the live connection is made to the terminal marked L and the neutral connection to the terminal marked N see Fig 2 exploded view
3. ED WITHOUT THE COVER CORRECTLY IN POSITION Warning In order to avoid a hazard due to inadvertent resetting of the thermal cutout this appliance must not be supplied through an external switching device such as a timer or connected to a circuit that is regularly switched on and off by the utility General The heater has a loading of 2kW It is designed for permanent wall mounting and is suitable for operation on A C electricity supply having the same voltage as shown on the rating label The heater is fitted with an internally mounted selector switch which on installation of the heater allows a choice of 1kW or 2kW output to suit the dimensions of the room to be heated In rooms of less than 9 11 cubic m 350 400 cubic ft 1kW output should be selected otherwise nuisance tripping of the thermal overload cut out may occur NOTE THE SWITCH HAS BEEN FACTORY SET FOR 1kW OPERATION IF ADDITIONAL OUTPUT IS REQUIRED 2kW CAN BE SET ON INSTALLATION SUPPLY CABLE IS NOT SUPPLIED WITH THIS APPLIANCE AND IT SHOULD THEREFORE BE INSTALLED BY ACOMPETENT ELECTRICIAN INACCORDANCE WITH THE LATEST IEE REGULATIONS Controls The cut out is a safety device which switches off the heater and fan if for any reason the appliance overheats see Safety The thermal fuse link is provided as an added safety feature and operates to open circuit if there is abnormal overheating within the appliance The operation of these safety devices i
4. O NOT USE THIS HEATER IN THE IMMEDIATE SURROUNDINGS OF A BATH A SHOWER OR A SWIMMING POOL DO NOT COVER THE APPLIANCE or place material or garments on it or obstruct the air circulation around this appliance for example with curtains or furniture as this could cause overheating and a fire risk DO NOT PLACE AEROSOLS OR OTHER CONTAINERS SUSCEPTIBLE TO HEAT IN THE DIRECT AIRFLOW FROM THE UNIT THIS HEATER MUST NOT BE LOCATED IMMEDIATELY BELOW A FIXED SOCKET OUTLET WARNING Do not operate the heater with the top cover removed This will trip the fuselink This heater must be installed so that the switches and other controls cannot be touched by the person in the bath or shower The appliance is not intended for use by children or other persons without assistance or supervision if their physical sensory or mental capabilities prevent them from using it safely Children should be supervised to ensure that they do not play with the appliance WARNING DISCONNECT THE HEATER FROM THE ELECTRICITY SUPPLY BEFORE UNDERTAKING SERVICE OR REPAIR WARNING If the appliance is fitted in a bathroom a cable outlet will be necessary with the supply to the unit controlled by a double pole switch The switch if inside the bathroom should be pull cord operated and if outside should be adjacent to the entrance door The appliance must be mounted so that no part of it can be touched by any person using bath or shower THIS HEATER MUST NOT BE OPERAT
5. XxX Dimplex A world of expertise Contact Details Please note that some of the contact details on this PDF document may not be current Please use the following details if you need to contact us Telephone 0844 879 3588 Email customer services gdcgroup co uk The customer support section of our website also features a wide range of information which may be of use to you and is available 24 hours a day It includes e Operating and installation instructions e Easy How to use guides for storage heaters e Service and repairs e Where to buy our products e Literature downloads e Heating requirement calculator Visit www dimplex co uk support A division of GDC Group Ltd Registered No 1313016 England Millbrook House Grange Drive Hedge End Southampton S030 2DF a nas sen ens tite i roqucer Registration Number www dimplex co uk WEE GE0057TS Paper from sustainable sources xX Dimplex Installation and Operating Instructions Downflow Fan Heater Model FX 20 IPX4 BEAB 08 35383 3 Issue 3 Approved Intertek IP24 Dimensions millimetres Model Specification FX 20 IPX4 High level 1 or 2kW adjustable thermostat internal by installer Ulllibllllllldla NK el O QQ oo WTNS NRU MQQOH N Floor MMMM 77 Fig 1 THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE IMPORTANT SAFETY ADVICE WARNING D
6. d by this guarantee Spares can be purchased on line go to www dimplex co uk outlet_store The product complies with the European Safety Standards EN60335 2 30 and the European Standard Electromagnetic Compatibility EMC EN55014 EN60555 2 and EN60555 3 These cover the essential requirements of EEC Directives 2006 95 EC and 2004 108 EC Dimplex UK Ltd Millbrook House Grange Drive Hedge End Southampton Hampshire S030 2DF c Dimplex UK Limited Technical Services UK customer help line 8 00am 5 00pm Mon Fri and 8 30am 1 00pm Sat October March 0844 870 3588 0844 879 3582 e mail technical services dimplex co uk All rights reserved Material contained in this publication may not be reproduced in whole or in part without prior permission in writing of Dimplex UK Limited
7. d not be disposed of with household waste Please recycle where facilities exist Check with your Local Authority or retailer for recycling advice in your country After Sales Service If this product appears damaged when first received or does not function correctly contact us by e mail aftersales dimplex co uk or ring 0844 879 35 88 and we will be able to help For ROI please phone 018424833 Do Not Return the product in the first instance as this may delay us providing you with a satisfactory service ACCIDENTAL DAMAGE IS NOT COVERED UNDER THE WARRANTY Your product is guaranteed for two years from the date of purchase Within this period we undertake to repair this product free of charge provided it has been installed and operated in accordance with these instructions Should you require assistance with this product please go to www dimplex co uk and click on Customer Support or e mail us at aftersales dimplex co uk Alternatively ring our contact centre on 0844 879 35 88 UK only This is a Lo call no from a BT landline other providers including mobile phones may charge you more For ROI please phone 01 842 4833 To assist you we will need the following information model number and serial no these can be found on the product nature of the fault and date of purchase Please retain your receipt as proof of purchase Your rights under this guarantee are additional to your statutory rights which in turn are not affecte
8. rheating within the appliance and servicing of the appliance by a competent service engineer will be required in order to ensure the future safe operation of the heater Dimplex Customer Services should be contacted who will arrange the replacement of any faulty parts and the fitting of a new fuse link Installation WARNING Minimum clearences must be adhered to when mounting the heater Before undertaking installation work ensure the electricity supply is disconnected from any relevant fixed wiring Supply cable is not supplied with this appliance and it should therefore be installed by a competent electrician in accordance with the latest IEE wiring regulations The supply circuit must be adequate for the input of the appliance and must be protected with a 13A fuse A suitable termination to the fixed wiring of the premises must be provided adjacent to the final position of the appliance through a double pole switch having a contact separation of at least 3mm in all poles Terminal Block Mains Cable o 7 Fig 2 Installation Procedure It is essential to observe minimum wall mounting clearances see Fig 1 The appliance should be fitted horizontally with the cable entry at the top and grille at the bottom It must be mounted not less than 1800mm above the floor with a clearance of at least 600mm to any shelf or projecting surface below the heater and
9. s described under Safety The pull cord switch operates the ON OFF switch An indicator light illuminates to show when the heater is ON and does not illuminate when the heater is OFF The heater is fitted with an adjustable thermostat which has three different settings 1 Low 2 Medium 3 High This gives you an approximate room temperature range of 18 C 32 C depending on room size The temperature switches to half heat when the room warms up Full heat will be switched on automatically when the room temperature falls This can be adjusted by installer by removing top cover The thermostat will only function when 2kW is selected The thermostat has been factory set on 2 medium To adjust the thermostat setting or reset selector switch first remove the top cover then adjust thermostat to required setting or reset selector switch to 1kW or 2kW as required then refit top cover Safety Cut Out For your safety this appliance is fitted with a thermal cut out In the event that the product overheats the cut out switches the heater off automatically To bring the heater back into operation remove the cause of overheating then turn off the electrical supply to the heater for a few minutes When the heater has cooled sufficiently reconnect and switch on the heater Fuse Link A thermal fuse link is provided as an added safety feature If the fuse link operates and opens circuit it is the result of abnormal ove