Procedure & User Programming Manual For All Digital

image

Contents

1. 7 OPERATI NG I NSTRUCTI ONS FOR HOTLINE MECH EXT SERIES 7 A WARNING Always do the following BEFORE operating your spa 1 2 3 4 5 6 Turn heater OFF Fill spa water Water level should be halfway up the skimmer opening Make sure all valves are open Release all air from heater chamber use air bleeder valve located on discharge side of the heater chamber provided in spa plumbing Turn jets on high for 5 minutes and make sure the pump is not surging Failure to follow these steps before operating the heater may cause a dry fire burnout the heater and will void your warranty G F C I Optional If not provided with the equipment pack a Ground Fault Circuit Interrupter G F C breaker must be installed 7 B1 The G F C I is located on the upper front panel of the control box 7 B2 Press red button on G F C IN and close spa door 7 B3 Push buttons located on spa side control and the system must function properly otherwise contact your local dealer or refer to troubleshooting manual 18 7 C 7 D 7 E 7 B4 G F C must be tested monthly preferably before each spa use by pushing black button IN the red button must pop OUT opening all electrical circuits By pressing red button IN red button must stay IN otherwise contact your local dealer or refer to troubleshooting manual FREEZE PROTECTING CIRCUIT 7 C1 For units with 7 day time clock RED a freeze
2. SYSTEMS Procedure amp User Programming Manual For All Digital Controls Acura Spa Systems I nc 2954 Rubidoux Blvd Riverside CA 92509 Phone 951 684 6667 Fax 951 684 6677 WWw acuraspa com Rev May 02 2007 TABLE OF CONTENTS SAFETY INSTRUCTIONS ccccccccesseeeeeenseeeeeenaseeseonaseeseeonaeeseaooaseeseonaseeseooaaeeseeonaeeessonasenenees 1 1 A WARNING cina c ot an ala a a aa a 1 1 B RISK OF CHILD DROWNING scie ta a is 1 1 C TO REDUCE THE RISK OF INJURY TO PEOPLE eee eee 1 INSTALLATION I NSTRUCTI ONS nenea aan ennneannnnennannnnnnna aan nnanaananeanna aan nnana aan nnanaaaannannazanaa 4 2 A ELECTRICAL INSTRUCTIONS sete e aa a at ae i i a a aaa d aa 4 2 B INSTALLATION OF PERMANENTLY INSTALLED UNITS nnne 4 2 Bl Generala sint da 4 2 B2 Wiring to Control Box 240V 4 Wire System meee eee 4 2 C INSTALLATION OF CORD AND PLUG CONNECTED UNITS ceea nenea 4 2 D BONDING See ea o ca 08 nian sad Wag Sai Pada es chee nee 5 2 E INSTALLATION OF POWER CORD nn ieee 5 OPERATING I NSTRUCTI ONS FOR POWERSTATI ON SERIES ococcccccoocccncononnconananonenanananenaas 6 3 A WARNING 2 0020 ati Aol die ai are a a Pa a WA Gen ea A A 6 3 B GF Crk ODPtlON al wes O NO 6 3 C Freeze Protection Operation m nenea nana errar 7 3 D Seven Day Time Clock Operation o oo 7 3 E Twenty Four Hour Time Clock Operation etter nn nr nn r cn Eeten EEEE 7 3 F SPA Side Control Optional ita aa a at t dala 8
3. SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS WARNING Before operating your spa do the following vie PE Turn Heater OFF Fill Soa with water Water level should be halfway up the skimmer opening Make sure that all the valves are open Release all air from filter and heater chamber see your filter s manual Turn jets on high for a few minutes NOTE FAI LURE TO FOLLOW THESE STEPS BEFORE OPERATING THE SPA SYSTEM MAY CAUSE A DRY FIRE AND WILL VOID YOUR WARRANTY 1 B RISK OF CHILD DROWNING 1 C DANGER Extreme caution must be exercised to prevent unsupervised access by children To avoid accidents ensure that children cannot use a Spa or hot tub unless they are closely supervised at all times TO REDUCE THE RI SK OF INJ URY TO PEOPLE DANGER 1 Do not remove suction fitting 2 RISK OF ELECTRICAL SHOCK Install at least 5 feet 1 5 meters from all metal surfaces Do not permit any electrical appliances such as radio television telephone lights etc within 5 feet 1 5 meters of a spa or hot tub 3 The water in a spa or hot tub should never exceed 104 F 40 C Water temperature between 100 F 38 C and 104 F 40 C is considered safe for a healthy adult Lower water temperatures are recommended for extended use exceeding 10 or 15 minutes and for young children Since excessive water temperature has a high potential for causing fetal damage during pregnancy pregnant or even possibly pregna
4. The pump motor bonding lug The heater bonding lug located on the manifold heater enclosure The blower bonding lug Any other non energized metal with 5 feet 1 5 meters of the spa or hot tub The bonding lug secured on the underside of the same metallic plate as the grounding conductor bar in the control box SA ie OPERATING INSTRUCTIONS Read all of the operating instructions BEFORE operating the systems 3 OPERATING I NSTRUCTI ONS FOR POWER STATION SERIES 3 A WARNING 3 B Always do the following BEFORE operating your spa a 2 3 4 5 6 Turn heater OFF Fill soa water Water level should be halfway up the skimmer opening Make sure all valves are open Release all air from heater chamber use air bleeder valve located on discharge side of the heater chamber provided in spa plumbing Turn jets on high for 5 minutes and make sure the pump is not surging Failure to follow these steps before operating the heater may cause a dry fire burnout the heater and will void your warranty G F C I Optional If not provided with the equipment pack a Ground Fault Circuit Interrupter G F C 1 breaker must be installed 3 B1 The G F C I is located on the upper front panel of the control box 3 B2 Press red button on G F C IN and close spa door 3 B3 Push buttons located on spa side control and the system must function properly otherwise contact your local dealer or refer to troubleshoot
5. located on spa side control marked jets Push jet button 7 F2 7 F3 7 F4 7 F5 once high speed pump comes on make sure pump is not surging turn thermostat knob clockwise to maximum heater light should come on except for 220V 30A and 120V 20A with thermostat know to maximum push jet button once more low speed pump will come on along with the ozonator make sure the rocker switch is in proper position Blower Air Button optional located on spa side control maybe marked warm air Push air button once to turn blower on Push air button once more to turn blower off Light Air Button optional located on spa side control marked spa light Push air button once to turn spa light on Push air button once more to turn Spa light off Booster Pump Air Button optional located on spa side control marked Booster Hi or Jet 2 Push air button once high speed pump will come on Push air button once more to turn high speed pump off Gentle Pump Air Button optional located on spa side control marked Gentle Pump Push air button once low speed pump will come on only if Booster Hi is off Push air button once more to turn low speed pump off 20 THE NEXT SECTION ONLY APPLIES TO DI GI TAL CONTROL SYSTEMS MEGATROL POWER MASTER QUICK SET MI NI TROL TINYTROL CHL Megatrol 21 Applies only for Digita
6. 14 5 F 1 Jet Air Button Optional eee ana 14 5 F 2 Blower Air Button Optional nenea 14 5 F 3 Light Air Button Optional eee 14 5 F 4 Booster Pump Air Button Optional e eee anna 14 5 F 5 Gentle Pump Air Button Optional eee eee 14 OPERATI NG I NSTRUCTI ONS FOR HOTLINE MECHANI CAL SERI ES nenea nenea nnaaeaa 15 6 A WARNING r aaa ar a dd 15 6 B GF Optional a dd 15 6 C Freeze Protection Operativa AAA as 16 6 D Seven Day Time Clock Operation o oo ies 16 6 E Twenty Four Hour Time Clock Operation eee 16 6 F SPA Side Control Optional tira aida iaa etnia 17 6 F 1 Jet Air Button Optional eee eee nea nenea 17 6 F 2 Blower Air Button Optional eee eee nea nana 17 6 F 3 Light Air Button Optional c cccccccssssseescceeeeeeseesecseeseeeeeseseeessaeeesesseesuaaeeerees 17 6 F 4 Booster Pump Air Button Optional c eee eee 17 6 F 5 Gentle Pump Air Button Optional ee eee eee 17 OPERATING I NSTRUCTI ONS FOR HOTLINE MECHANI CAL EXT SERIES ssscssseesseeesees 18 7 A WARNING ao a A da 18 7 B GF Gil Optional A sk 18 7 C Freeze Protection Operation m nenea ener eee nana 19 7 D Seven Day Time Clock Operation 0 0 cc ee nn nono rare 19 7 E Twenty Four Hour Time Clock Operation eee 19 7 F SPA Side Control Optional ss si ic ie Ai 20 7 F 1 Jet Air Button Optional eee eee ana 20 7 F 2 Blower Air Button Optional 20 T F 3 ight Air Bu
7. 3 D3 Turn temperature control to maximum 3 D4 Select the desired time on 7 day time clock to start operating low speed pump and heater TWENTY FOUR HOUR TI ME CLOCK OPERATION 3 E1 The 24 hour time clock is set to control low speed pump and ozonator 3 E2 The 24 hour time clock has 48 permanently attached trippers that can easily be set by hand without any tools Each tripper would turn low speed pump ON for thirty minutes 3 F 3 E3 Toggle switch located on left side of 24 hour time clock must be in up position Timer for the time clock to operate SPA SIDE CONTROL OPTIONAL Spa side control is located on spa shell could be provided with a temperature controller thermostat 3 F1 Jet Air Button located on spa side control marked jets Push jet button 3 F2 3 F3 3 F4 3 F5 once high speed pump comes on make sure pump is not surging turn thermostat knob clockwise to maximum heater light should come on except for 220V 30A and 120V 20A with thermostat know to maximum push jet button once more low speed pump will come on along with the ozonator make sure the rocker switch is in proper position Blower Air Button optional located on spa side control maybe marked warm air Push air button once to turn blower on Push air button once more to turn blower off Light Air Button optional located on spa side control marked spa light Push air button
8. 3 F 1 Jet Air Button Optional eee nenea ana 8 3 F 2 Blower Air Button Optional eee 8 3 F 3 Light Air Button Optional eee 8 3 F 4 Booster Pump Air Button Optional ee eee nenea 8 3 F 5 Gentle Pump Air Button Optional eee nn 8 OPERATI NG I NSTRUCTI ONS FOR POWERQUIP SERI ES ccooococcccocoooccnnnaonnennanannncnanananennas 9 4 A WARNING A d mau e pata ta 9 4 B GFC Optional saga i scot pata a are Oa aaa Sa ca cadets a ai tata ae ta a ai tal la ia 9 4 C Freeze Protection Operation sisanra eee eee anna 10 4 D Seven Day Time Clock Operation nenea nenea e aan nana 10 4 E Twenty Four Hour Time Clock Operation eee eee 10 4 F SPA Side Control Optional esiaine eee eee eee nenea nenea 11 4 F 1 Jet Air Button OPINA ita winded miata 11 4 F 2 Blower Air Button Optional eee 11 4 F 3 Light Air Button Optional eee nenea nene 11 4 F 4 Booster Pump Air Button Optional eerie 11 4 F 5 Gentle Pump Air Button Optional ccccccsceceesseeeeeeeeeseeeeeeeeseeeeeaenseeeeeesaaenees 11 OPERATI NG I NSTRUCTI ONS FOR POWER SOURCE SERIES ssssssnsssnnnnnnnnnnnnnnnnnnnnnnnnnnnnnna 12 5 A INARNING a bip 12 5 B GFC Optional io ea aaa a a A ead a a 12 10 11 5 C Freeze Protection Operation m nenea ener errar 13 5 D Seven Day Time Clock Operation nn corn nn nr rar 13 5 E Twenty Four Hour Time Clock Operation eee 13 5 F SPA Side Control Optional as sea a a aaa te 0 au aaa a ida
9. If indicator light B is ON and the high pump indicator on the Top Side control is ON then the PC board relay is not engaging Change the PC Board removing the plastic cover on the relay may free a stuck relay switch Heater 1 ON Indicator light I is ON there is voltage on heater terminal The heater should be heating unless the heating element is bad to confirm a bad heating element use an Amp meter and verify the amperage when indicator light I is ON Indicator light I is OFF If the heater indicator on the Top Side control is ON and the Top Side LED is displaying PSOL PSOH or PSOC refer to section 17 F below Pumps Blower Heater 2 These are optional items and may or may not be installed in your spa If these items are installed then the appropriate indicator light s will be ON when there is power to that device The troubleshooting above apply to these items also Note The indicator lights do not display power levels such as 115 V or 230 V they only indicate that voltage is ON to that circuit 40 17 ERROR MESSAGES There are 9 error messages that the digital controls may display Here is a list of these messages and what they indicate 17 A CoLD Temperature in the spa heater housing is below 40 Fahrenheit Because spa 17 B OH 17 C HLEr temperature should never get this low the status of the heater element is unknown Therefore the low speed or circulation pump will
10. button must stay IN otherwise contact your local dealer or refer to troubleshooting manual FREEZE PROTECTING CIRCUIT 6 C1 For units with 7 day time clock RED a freeze protection switch is located on the left side of the 7 day time clock to override the 7 day time clock and let slow speed pump and heater be controlled by the thermostat SEVEN DAY TI ME CLOCK OPERATION 6 D1 The 7 day time clock is set to control the heater as well as low speed pump simultaneously The 7 day time clock provides setting each day of the week or operation may be discontinued on any day of the week Each tripper will turn heater on for a minimum of three hours The 7 day time clock has 56 permanently attached trippers that can easily be set by hand without any tools 6 D2 Toggle switch located on the left side of the 7 day clock must be in the up position Timer for the time clock to operate 6 D3 Turn temperature control to maximum 6 D4 Select the desired time on 7 day time clock to start operating low speed pump and heater TWENTY FOUR HOUR TI ME CLOCK OPERATION 6 E1 The 26 hour time clock is set to control low speed pump and ozonator 6 E2 The 26 hour time clock has 48 permanently attached trippers that can easily be set by hand without any tools Each tripper would turn low speed pump ON for thirty minutes 6 E3 Toggle switch located on left side of 26 hour time clock must be in up position Timer for the time clock
11. in the spa is so low as to permit air to be sucked in by the pump To bleed an air lock loosen one of the heater fittings and or a pump fitting a turn You will hear the sound of escaping air then water will start dripping Re tighten the fitting Use air bleeder manual provided by spa manufacturer 17 G CboH Control Box Overheat Summer temperatures and a well insulated spa can 17 H ToE cause the ambient temperature in the control box to rise more so if one or more pumps are running This error code indicates that the ambient temperature inside the control box is over 115 F and the spa water temperature may not be accurately measured To eliminate this error turn the spa off for a time and or vent the equipment compartment Time Out Error It is not likely that you will ever see this error it indicates that the system s heartbeat is out of control All devices will be shutdown and the Spa is unusable This message will rarely ever occur but if it does please contact Acura Spa Systems Inc 42 18 ELECTRICAL CONNECTION INSTRUCTIONS NOTICE All spa electrical wiring must be performed by a qualified licensed electrician and must meet all NEC National Electric Code and state and local codes and requirements DANGER RISK OF ELECTRIC SHOCK 1 The lines carrying power to the spa must be dedicated to the spa and should not be shared with any other appliance s 2 All electrical wiring lines must originate form the electrica
12. once to turn spa light on Push air button once more to turn spa light off Booster Pump Air Button optional located on spa side control marked Booster Hi or Jet 2 Push air button once high speed pump will come on Push air button once more to turn high speed pump off Gentle Pump Air Button optional located on spa side control marked Gentle Pump Push air button once low speed pump will come on only if Booster Hi is off Push air button once more to turn low speed pump off 4 OPERATING I NSTRUCTI ONS FOR POWERQUIP SERIES 4 A WARNING Always do the following BEFORE operating your spa l 2 3 4 5 6 Turn heater OFF Fill spa water Water level should be halfway up the skimmer opening Make sure all valves are open Release all air from heater chamber use air bleeder valve located on discharge side of the heater chamber provided in spa plumbing Turn jets on high for 5 minutes and make sure the pump is not surging Failure to follow these steps before operating the heater may cause a dry fire burnout the heater and will void your warranty G F C 1 Optional If not provided with the equipment pack a Ground Fault Circuit nterrupter G F C breaker must be installed 4 B1 The G F C is located on the upper front panel of the control box 4 B2 Press red button on G F C IN and close spa door 4 B3 Push buttons located on
13. protection switch is located on the left side of the 7 day time clock to override the 7 day time clock and let slow speed pump and heater be controlled by the thermostat SEVEN DAY TI ME CLOCK OPERATION 7 D1 The 7 day time clock is set to control the heater as well as low speed pump simultaneously The 7 day time clock provides setting each day of the week or operation may be discontinued on any day of the week Each tripper will turn heater on for a minimum of three hours The 7 day time clock has 56 permanently attached trippers that can easily be set by hand without any tools 7 D2 Toggle switch located on the left side of the 7 day clock must be in the up position Timer for the time clock to operate 7 D3 Turn temperature control to maximum 7 D4 Select the desired time on 7 day time clock to start operating low speed pump and heater TWENTY FOUR HOUR TI ME CLOCK OPERATION 7 E1 The 27 hour time clock is set to control low speed pump and ozonator 7 E2 The 27 hour time clock has 48 permanently attached trippers that can easily be set by hand without any tools Each tripper would turn low speed pump ON for thirty minutes 7 E3 Toggle switch located on left side of 27 hour time clock must be in up position Timer for the time clock to operate 19 7 F SPA SIDE CONTROL OPTIONAL Spa side control is located on spa shell could be provided with a temperature controller thermostat 7 F1 Jet Air Button
14. run continuously until temperature rises above 45 F A spa should not be filled with water below 40 F Please note that a running pump can heat the spa at approximately Y F per hour During this error condition the spa is functional except for the heater OverHeat The spa is at a temperature that is above 108 F Control will not accept temperature setting above 104 F If for some reason the spa temperature rises over the maximum level the controller will display a flashing 105 F to 108 F If temperature goes past 108 F then the OH message will be displayed instead of temperature The spa is still operational but hotter than any person should be subjected to Please do not use your spa when the temperature is flashing or the OH message is displayed In the summer and especially in warm regions ambient temperature may be high enough to overheat the spa naturally Spas are usually well insulated and can store a lot of heat in the equipment compartment Hi Limit Over Heat Digital controls have a backup water temperature sensor called the Hi Limit If the sensor is disconnected or shorted or if the spa temperature should reach above 112 F the Hi Limit protection circuitry will force all spa functions OFF and will flash the HLEr message on the display It is not possible to use the spa when this error is active Even after the temperature goes down to an acceptable level or the sensor is repaired replaced When the error has been correc
15. seconds of every minute if the time of day has been set 1 Do NOT display TOD If TOD was not set by the user then it most probably is incorrect and the controller will not display it even if U5 is 0 0 If line frequency is 60 hz then display temperature in Fahrenheit If 50 hz then display Centigrade 1 If line frequency is 60 hz then display temperature in Centrigrade If 50 hz then display Fahrenheit RESERVED do not change Leave set to 0 RESERVED do not change Leave set to 0 The default setting for all U options is 0 36 16 B Protected Options Warning Changing any of the protected options may be dangerous and can result in injury It can also damage the spa and it s equipment as well Changes made by the user are at his her own risk All liability rests with the person doing the changes Only trained service personnel should make changes If unsure please contact Acura Spa Systems I nc P1 P2 P3 P4 P5 P6 P7 P8 0 There is no additional circulating pump The primary pump is usually 2 speed The low speed is the filtering and heating pump 1 A circulating pump is attached to the system 0 The primary pump is a 2 speed pump 1 The primary pump is a single speed pump Note The circulating pump is always attached through the heater All filtration and heating is done with the circulating pump when one is attached to the system 0 The system has high amps available
16. to operate 16 6 F SPA SIDE CONTROL OPTIONAL Spa side control is located on spa shell could be provided with a temperature controller thermostat 6 F1 Jet Air Button located on spa side control marked jets Push jet button 6 F2 6 F3 6 F4 6 F5 once high speed pump comes on make sure pump is not surging turn thermostat knob clockwise to maximum heater light should come on except for 220V 30A and 120V 20A with thermostat know to maximum push jet button once more low speed pump will come on along with the ozonator make sure the rocker switch is in proper position Blower Air Button optional located on spa side control maybe marked warm air Push air button once to turn blower on Push air button once more to turn blower off Light Air Button optional located on spa side control marked spa light Push air button once to turn spa light on Push air button once more to turn Spa light off Booster Pump Air Button optional located on spa side control marked Booster Hi or Jet 2 Push air button once high speed pump will come on Push air button once more to turn high speed pump off Gentle Pump Air Button optional located on spa side control marked Gentle Pump Push air button once low speed pump will come on only if Booster Hi is off Push air button once more to turn low speed pump off 17
17. 1 The system is only capable of 20 or 30 amps low power In this mode the heater can only operate with the low or circulating pump Itis disabled with all other selections 0 The LITE key operates as an ON OFF switch The light relay and the accessory relay if installed operate together 1 The LITE key is a 3 function key e Press once the spa light is turned ON e Press again both spa light is ON and accessory is ON Press a third time for both functions to turn OFF 0 Reserved Do not use this function 0 Air blower is enabled The AIR key is active 1 Air blower is disabled The AIR key is deactivated condary pump is a single speed pump 0 1 condary pump is a dual speed pump Se Se 0 There is only one secondary pump 1 There are two secondary pumps Note If P8 is ON then by definition both secondary pumps must be single speed Warning An improper setting of P7 and P8 can result in damage or even destroyed pump motors It can also cause the controller s printed circuit board to catch fire Only trained service personnel should carry out changes If unsure please contact Acura Spa Systems Inc 37 16 C Diagnostic Values The D options are internal values and may not be changed from the control panel When a D message is displayed press the SET key to see what the associated value is Here is a brief explanation D1 D2 D3 D4 D5 D6 D7 D8 What the microprocessor is r
18. ITE Spa Light amp Accessory Both Both ON OFF Spa Light amp Accessory Light Both Both 3 Function ON ON OFF Table 1 Device keys summary of functions The four device keys JETS AIR AUX and LITE are exclusive when one is pressed no other key may be pressed simultaneously You must release the pressed key before you may press another key Also these keys do not repeat If you press and hold a key for more than 20 seconds that key will be considered defective collapsed and will be deactivated and ignored by the system When released the key will stay inactive for 20 seconds before it is recognized and activated 27 13 STATUS CONTROL GROUP The keys in this group are used to communicate to the controller system settings and option selection s There are 3 keys in this group and 3 functions that are combinations of these keys Key Press Function TEMP up arrow Prog Temp or Next TIME down arrow Prog TOD or Previous SET key Select or Accept Enter SET amp TEMP Invert display SET amp TIME Parameter programming TEMP amp TIME System programming Table 2 Status Control Keys Summary 13 A The TEMP key which is also the UP ARROW key is a repeat key if held down Think of this key as or next Use it to Press and hold for 2 seconds then release it to start desired temperature selection During temperature setting press TEMP to increase selected temperature Wh
19. TION OF PERMANENTLY INSTALLED UNITS 2 B1 GENERAL 1 Su The electrical supply for this unit must include a suitably rated switch or circuit breaker to open all ungrounded supply conductors to comply with Section 422 20 of National Electric Code ANSI NFPA 70 1987 a disconnecting means must be readily accessible to the hot tub occupant but installed at least 5 feet 1 5 meters from the hot tub water Remove the bottom front panel of the control box the terminal block is located approximately 3 5 from the incoming power cord User copper conductors only If a Ground Fault Circuit Interrupter G F C is not provided with the unit an electrician must install a G F C l breaker as of January 1 1994 as per the National Electric Code 2 B2 Wiring to Control Box 240V 4 Wire System IS Ground to power terminal block is marked G Neutral to power terminal block is marked N Hot to power terminal block is marked L2 Hot to power terminal block is marked L1 INSTALLATION OF PERMANENTLY INSTALLED UNITS 1 2 3 Connect to a grounded grounding type receptacle only Never connect the spa to an extension cord Do not bury cord Replace damaged cord immediately 2 D BONDING 2 E The enclosure of each electrical component and all other metal that could be energized and is accessible to the person servicing the equipment shall be bonded to the ground conductor bar This includes the following
20. acility please contact the service department of the factory 3 Units shipped to service facility must be in original shipping carton and or properly packed to prevent damage freight prepaid and fully insured Acura Spa Systems will return units freight collect Please include proof of purchase and description of problem with attached Return Goods Authorization Do not ship without paper Return Goods Authorization Please contact the factory to obtain your Return Goods Authorization number Expenses of shipment and cost of repair of products to an authorized Acura Spa Systems service facility are the responsibility of the purchaser 4 Installation and removal labor is the responsibility of the purchaser 5 For warranty to be effective a maintenance record of regular service must be provided 6 Installer s electrical license number must be provided Warranty Limitations Limited Warranty provided by Acura Spa Systems does not cover A Spa shell spa skirt modifications of original product or component not part of Acura Spa Systems products B Any defect malfunction or failure caused by or resulting from improper service maintenance installation or water supply to pump water chemistry packaging for return or repairs made or attempted by other than Acura Spa Systems neglect accident or any other cause beyond the control of Acura Spa Systems C Uncrating set up or installation adjustment of customer operated controls D Any
21. arded Previous save changes Changes saved Exit programming mode Display current spa temperature time or operating message The table on the following pages is a list of all menu items their minimum default and maximum values and an explanation of the function of each parameter Note Time parameters have two components the hours and the minutes When programming a time element first the hour portion is programmed flashing When the hours are set press the SET key to program the minutes portion 31 15 PARAMETER MENU LISTS Msg FP1 FP2 FP3 FP4 SIL FP1d FP2d FP3d FP4d SILd Min Ooo0ooOoOo Def 12 00 12 00 12 00 12 00 12 00 OooooOoOo Max Detail Start time of filtration period 1 Start time of filtration period 2 Start time of filtration period 3 Start time of filtration period 4 Note f filtration periods overlap the most recent period last is in effect Start time of filtration period This is a period during which nothing will run It overrides all filtrations the economy cycle and temperature sampling Except if temperature drops below 40 F or if temperature reading drops more than 10 F below the set temperature then the low speed pump may turn on to prevent the pipes from freezing A spa may be installed near a bedroom and need not come on at specific times for example between midnight and 7 in the morning Duration in minutes FP1 timer will run Durati
22. as well as failure of other components in the system Failures caused by chemical imbalance are not covered by warranty 22 9 INAHURRY READ THIS For those who dont like to read manuals or would like to read the manual later please read at least the following section Your control system comes to you programmed with a universal set of default settings If you choose to keep these settings then you only need to remember two things how to set the spa temperature and to press the SET key whenever you are done using the spa Setting Temperature Press and hold the TEMP key for 2 seconds then release all keys The display will flash the current selected temperature Using the TEMP and TIME keys UP or DOWN arrows scroll to the desired temperature e Press the SET key to lock in the new selection The SET Key After using the spa press the SET key to tell the microcontroller you are done using the spa It will then take over the spa s management including the different filtration cycles heat maintenance economy modes and protection against freezing Upon entering this mode the FILTER light is turned on and a post use filtration cycle is executed that is when the spa needs filtration the most The default system setting includes a 3 hour economy mode the pump will come on at most once every 3 hours to sample water temperature and heat if necessary The controller remembers when you have used the spa and in anticipation of y
23. changes made to all parameters This menu message has no numerical value Pressing SET while it is displayed discards all changes made to all parameters WARNING The recommended maximum temperature of a spa is 104 F The absolute maximum beyond which no one should ever be exposed is 108 F When you calibrate the spa temperature you are doing so at your own risk Obtain an accurate medical thermometer to check against Please contact Acura Spa Systems Inc for proper procedure or if you do not feel confident 34 16 PROGRAMMING SYSTEM OPTIONS Systems Options Programming is a means of setting the various system options The U and P options are of the ON OFF or 1 0 type the option is either 1 or ON or it is O or OFF The D options can only be displayed and may not be changed by the user To initiate options programming press the UP and DOWN arrows together There are 3 groups of 8 options each User Options U1 to U8 Protected Options P1 to P8 Diagnostics D1 to D8 When programming groups 1 and 2 U and P options either the letter U or the letter P is displayed followed by a number 1 to 8 a space and the number 1 if the option is ON or 0 if the option is OFF For example if the third user option was OFF the letters U3 0 will be displayed If it was ON the display will read U3 1 Use the scroll buttons UP and DOWN to navigate through the different options Press the SET key to toggle a displayed option s status
24. ck in the new hour 5 The display will now flash the minutes portion of current TOD 6 Using TIME and TEMP scroll to the desired minutes 7 When the correct minutes are displayed press the SET key to lock in the time of day hour and minutes Note TOD is the only parameter in your control system that is not preserved on power down On power up it will default to 12 00 AM all other parameters are restored to their last setting Every time the controller is powered up the microprocessor automatically measures and determines the line frequency is 50 or 60 cycles in order to maintain the correct TOD 24 11 THE CONTROL PANEL The control panel is normally installed on the lip of the spa for easy and convenient access Within the panel housing is a 4 digit LED display used to communicate to the user the spa temperature TOD elapsed user time programming status diagnostic and error codes and messages There are two 2 different panel sizes and they are interchangeable The PM 3002 Series panel can have up to 7 keys and the HL 2000 Series panel will have at most 6 keys These are membrane type switches which when depressed generate a signal that the microprocessor will interpret and act upon The switches are labeled and have specific functions They are divided into 2 groups Device Control Group Pump s Air Blower Spa Light keys Status Control Group Up Down Set keys Note f any of the keys is pressed and held closed f
25. d on the control box receptacle between the white and red wires If the pump is wired correctly then the low speed pump is ON If the low speed pump is not ON then C1 The pump motor is bad C2 The motor has a tripped thermo overload due to high ambient temperature in the equipment bay ambient temperature higher than 122 F C3 Voltage drop below 216 Volts may cause the motor to overheat A marked 230 Volt motor will not operate below 207 Volts 60 Hz A marked 115 Volt motor will not operate below 104 Volts 60 Hz Indicator light C is OFF C4 If indicator light B is ON and the low pump indicator on the Top Side control is ON then the PC board relay is not engaging 39 Change the PC Board removing the plastic cover on the relay may free a stuck relay switch D High Pump High Pump ON l Heater 1 E F G H J Indicator light D is ON voltage is measured on the control box receptacle between the white and black wires If the pump is wired correctly then the high speed pump is ON If the high speed pump is not ON then D1 The pump motor is bad D2 The motor has a tripped thermo overload due to high ambient temperature in the equipment bay ambient temperature higher than 122 F D3 Voltage drop below 216 Volts may cause the motor to overheat A marked 230 Volt motor will not operate below 207 Volts 60 Hz A marked 115 Volt motor will not operate below 104 Volts 60 Hz Indicator light D is OFF D4
26. dicate when the air blower is on 12 C Auxiliary Pump s Your spa may be equipped with 1 or 2 more pumps If you have a second pump it could be a single speed or a dual speed If you have a third pump then both the second and third pumps must be single speed The function of the AUX key changes with the number and type of auxiliary pumps used Please consult with the table on the following page for the proper sequence of activation 12 D Spa Light The LIGHT key can also be a multifunction key In its simplest configuration the LIGHT key is a Simple on off switch It turns the spa light and the accessory if one is attached on off together at the same time Alternatively the LIGHT key may be programmed as a 3 function key Pressing it once will turn the spa light on Pressing it a second time will turn on the attached accessory while the light is still on Press it a third time and both the spa light a accessory will go off Table 1 summarizes all the possible device key combinations Please note that your spa may not necessarily have all these devices attached 26 12 E SUMMARY OF FUNCTIONS FOR EACH DEVICE Key Device 1 2 3 4 Single speed pump ON OFF JETS Dual speed pump LOW HIGH OFF Dual speed with Circ pump LOW HIGH OFF Circ pump is independent AIR Single speed air blower ON OFF One single Speed pump ON OFF AUX One dual speed pump LOW HIGH OFF Two Single speed pumps P1 P1 amp P2 P2 ALL OFF Spa light ON OFF L
27. e hour and the minutes When a message is displayed during parameter programming press SET to select that message When a parameter value is displayed press SET to accept the displayed value and return to message display During option programming press SET to toggle a parameter ON or OFF When a HLoH error message is displayed press the SET key to clear the error if the cause has been corrected Pressing the SET key the user acknowledges that the cause of the hi limit error has been or will be corrected NOTE UP is synonymous with TEMP and DOWN is the same key as TIME These are used interchangeably and mean the same thing Scrolling means pushing either the UP or the DOWN key to go to the next or previous item or value 29 14 PROGRAMMING THE PM 3002 amp HL2000 14 A Parameter Programming is a means by which the spa owner user can change the various timing elements and calibrate temperature The process is simple and intuitive Only 3 keys are used UP DOWN and SET To program one or more parameters follow this outlined procedure 1 Press the SET and DOWN keys together The first message in the menu FP1 will be displayed 2 Use the UP amp DOWN keys to scroll through the messages in the menu 3 Press the SET key to display the current value associated with the current message 4 Use the UP or DOWN keys to increase or decrease the value 5 Press SET to lock in the new value and return to the menu 6 If a
28. eading as relative temperature What the microprocessor is reading from the keys What the microprocessor is sending to the relays Accumulated count of temperature errors encountered Accumulated count of hi limit errors encountered Accumulated count of heartbeat errors encountered The firmware revision number The manufacturing year and week in the form yyww 38 16 D Megatrol Indicator Lights A 120V Power Supply to Terminal Block 11 Ni B 240 Power Supply to Terminal Block L1 L21 C Low Pump ON D High Pump ON E 27 Pump High ON F 3 Pump High ON OR 2 Pump Low ON G 4 Pump High ON H Blower ON Heater 1 ON J Heater 2 ON 5 Optional Items The indicator lights provided on the upper left side of the Megatrol series indicate the A C Power supply to the control box as well as the A C Power from the control box to the Pump s Heater s and Blower if installed The Indicator Lights are defined as A 120V Power Supply to Terminal Block L1 N Indicator light A is ON 120 Volts is supplied to the Terminal Block Indicator light A is OFF 120 Volts is not supplied to the Terminal Block B 240V Power Supply to Terminal Block L1 L2 Indicator light B is ON 240 Volts is supplied to the Terminal Block Indicator light B is OFF 240 Volts is not supplied to the Terminal Block C Low Pump Low Pump ON Indicator light C is ON voltage is measure
29. ed Gentle Pump Push air button once low speed pump will come on only if Booster Hi is off Push air button once more to turn low speed pump off 14 6 OPERATI NG INSTRUCTIONS FOR HOTLINE MECH SERIES 6 A WARNING 6 B Always do the following BEFORE operating your spa 1 2 3 4 5 6 Turn heater OFF Fill spa water Water level should be halfway up the skimmer opening Make sure all valves are open Release all air from heater chamber use air bleeder valve located on discharge side of the heater chamber provided in spa plumbing Turn jets on high for 5 minutes and make sure the pump is not surging Failure to follow these steps before operating the heater may cause a dry fire burnout the heater and will void your warranty G F C I Optional If not provided with the equipment pack a Ground Fault Circuit Interrupter G F C 1 breaker must be installed 6 B1 The G F C I is located on the upper front panel of the control box 6 B2 Press red button on G F C IN and close spa door 6 B3 Push buttons located on spa side control and the system must function properly otherwise contact your local dealer or refer to troubleshooting manual 6 B4 G F C must be tested monthly preferably before each spa use by pushing black button IN the red button must pop OUT opening all electrical circuits 15 6 C 6 D 6 E By pressing red button IN red
30. en doing system programming press TEMP to scroll to the next message After message selection the system displays the associated value press TEMP to increase the value gt o NOTE When the display is inverted you will be able to read the display from inside the spa However the keys will retain their functions and will not be inverted The UP ARROW will still function as the UP ARROW even though when you look at it from within the spa it appears to be the DOWN ARROW The same also applies to the rest of the keys 13 B The TIME key which is also the DOWN ARROW key is also a repeat key Think of it as or previous Use it to Press and hold for 2 seconds then release it to start setting the real time clock TOD During time setting press TIME to decrease the hours or minutes value that is being set When doing system programming press TIME to scroll to the previous message After selecting a message the system displays the associated value press TIME to decrease the value 28 13 C The SET key is equivalent to Select or Accept It functions as an Enter key of a personal computer it is the proverbial hit any key to continue Press the Set key to After using the spa press the SET key to tell the controller to take over the management of the spa During temperature setting press the SET key to lock in a new selected temperature During time of day programming press the SET key to lock in th
31. from 0 to 1 or vice versa Go to SEND and press SET to save changes Alternatively go to CANC and press SET to discard all changes and restore previous settings The Diagnostics are not options but rather they display internal values that are indicative of the internal state of the processor They are useful for a serviceman or a technician to pinpoint hardware problems and error conditions The following tables list the User Options and the Protected Options and their significance when they are ON and OFF 35 16 A User Options Ul U2 U3 U4 U5 U6 U7 U8 0 Economy mode is ON In this mode water temperature is sampled every 3 hours or whatever ECL is set to If the spa is being used the economy mode is OFF 1 Auto Maintenance is ON Temperature is sampled and acted upon continuously 0 Low pump on demand The low pump will come on to sample the temperature heat or filter the spa as needed 1 The low pump runs all the time 0 Auto Filtration is one 3 hour long period The length of this period is fixed and cannot be changed It is the minimum recommended filtration time for a Spa 1 Auto Filtration is two periods each 3 hours long The second period starts 12 hours after the first period is executed 0 User timer starts with the first key pressed and shuts the spa off at the end of countdown 1 The user timer is restarted every time a key is pressed 0 Display TOD time of day the first 10
32. h spa use by pushing black button IN the red button must pop OUT opening all electrical circuits 12 5 C 5 D 5 E By pressing red button IN red button must stay IN otherwise contact your local dealer or refer to troubleshooting manual FREEZE PROTECTING CIRCUIT 5 C1 For units with 7 day time clock RED a freeze protection switch is located on the left side of the 7 day time clock to override the 7 day time clock and let slow speed pump and heater be controlled by the thermostat SEVEN DAY TI ME CLOCK OPERATION 5 D1 The 7 day time clock is set to control the heater as well as low speed pump simultaneously The 7 day time clock provides setting each day of the week or operation may be discontinued on any day of the week Each tripper will turn heater on for a minimum of three hours The 7 day time clock has 56 permanently attached trippers that can easily be set by hand without any tools 5 D2 Toggle switch located on the left side of the 7 day clock must be in the up position Timer for the time clock to operate 5 D3 Turn temperature control to maximum 5 D4 Select the desired time on 7 day time clock to start operating low speed pump and heater TWENTY FOUR HOUR TI ME CLOCK OPERATION 5 E1 The 25 hour time clock is set to control low speed pump and ozonator 5 E2 The 25 hour time clock has 48 permanently attached trippers that can easily be set by hand without any tools Each tripper
33. h speed pump will come on Push air button once more to turn high speed pump off Gentle Pump Air Button optional located on spa side control marked Gentle Pump Push air button once low speed pump will come on only if Booster Hi is off Push air button once more to turn low speed pump off 11 5 OPERATI NG INSTRUCTIONS FOR POWER SOURCE AND MEGATROL SERIES 5 A WARNING Always do the following BEFORE operating your spa 1 2 3 4 5 6 Turn heater OFF Fill spa water Water level should be halfway up the skimmer opening Make sure all valves are open Release all air from heater chamber use air bleeder valve located on discharge side of the heater chamber provided in spa plumbing Turn jets on high for 5 minutes and make sure the pump is not surging Failure to follow these steps before operating the heater may cause a dry fire burnout the heater and will void your warranty G F C I Optional If not provided with the equipment pack a Ground Fault Circuit Interrupter G F C 1 breaker must be installed 5 B1 The G F C I is located on the upper front panel of the control box 5 B2 Press red button on G F C IN and close spa door 5 B3 Push buttons located on spa side control and the system must function properly otherwise contact your local dealer or refer to troubleshooting manual 5 B4 G F C must be tested monthly preferably before eac
34. ing manual 3 C 3 E 3 B4 G F C must be tested monthly preferably before each spa use by pushing black button IN the red button must pop OUT opening all electrical circuits By pressing red button IN red button must stay IN otherwise contact your local dealer or refer to troubleshooting manual FREEZE PROTECTING CIRCUIT 3 C1 For units with 7 day time clock RED a freeze protection switch is located on the left side of the 7 day time clock to override the 7 day time clock and let slow speed pump and heater be controlled by the thermostat NOTE If filtration is needed pull time clock pins OUT alloys low speed pump to run during the selected time interval refer to paragraph 3 D 3 C2 For units with 24 hour time clock BLUE a freeze protection switch is provided to override the 24 hour time clock and let low speed pump operate continuously SEVEN DAY TI ME CLOCK OPERATION 3 D1 The 7 day time clock is set to control the heater as well as low speed pump simultaneously The 7 day time clock provides setting each day of the week or operation may be discontinued on any day of the week Each tripper will turn heater on for a minimum of three hours The 7 day time clock has 56 permanently attached trippers that can easily be set by hand without any tools 3 D2 Toggle switch located on the left side of the 7 day clock must be in the up position Timer for the time clock to operate
35. l Controls Megatrol Power Master Quick Set Minitrol Tinytrol amp CHL 8 INTRODUCTION Thank you for buying a spa equipped with a digital spa control system from Acura Spa Systems Inc Many years of experience went into the design of this family of controls You can be assured your spa control system is the most advanced it is highly reliable and will serve you for many years to come The control system has been designed with you the user in mind It is very easy to operate and requires a minimal effort on your part You may use it just as it comes to you and without any programming Yet you have the option of getting deeply involved in the inner workings of the control if you so choose You can custom tailor it to fit your needs Please take the time to read at least the first section IN A HURRY READ THIS portion of the manual before starting to use your spa for the first time You can familiarize yourself with the rest of the manual at your leisure This manual will also serve as a reference if you choose to modify the operation of your spa SAVE THIS MANUAL Make it available for other spa users You should also have a Spa user s manual which explains how to care for your spa Please read and follow all instructions in your spa user s manual Maintaining the proper levels of pH and the sanitizer will extend the life of you spa equipment Improper chemical levels in the spa are sure to cause premature heater failure
36. l panel and terminate hard wired into the electrical wiring compartment The use of extension cord or plug type termination is expressly prohibited and voids the warranty 3 Do not use aluminum wire Use copper wire only 4 Wire gauge must be in accordance with NEC requirements for the distance from current source to spa and the current rating as stated on the ID label that is attached to the control enclosure 5 A grounded metal conduit must shield all wiring The conduit must be terminated at the electrical access compartment either from the bottom of the spa or through a hole in the side paneling of the spa 6 For a 120 volt system the line wire black is connected to the terminal block lug labeled LINE1 The neutral wire white is connected to the center lug labeled NEUT and the ground wire green is connected to the ground lug labeled G or GROUND 7 For a 240 volt 4 wire system connect Linel Neutral and Ground wires as in 6 above The fourth wire is the Line2 wire red and it is connected to the lug labeled LINE2 8 For a 240 volt 3 wire system connect black line wire to LINE1 terminal connect red line wire to LINE2 terminal and the green wire to the ground lug There is no neutral 43 19 BRANCH CIRCUIT BREAKER REQUIREMENTS 240 Volts 4 Wire System 30 50 Amp 2 Pole Breaker 240 Volts 3 Wire System 30 50 Amp 2 Pole Breaker 120 Volt 3 Wire System 20 Amp 1 Pole Breaker CAUTION A new breaker must be used for a
37. les Wires 240V 40 50 Amps 2 4 120V 20 Amps 1 3 3 Terminal Block Connection Terminal Block Li N LINE 1 1204 BLACK NEUTRALAVHITE LINE 2 RED 1204 GROUND Ea mm DN iw 4 Terminal Block Connection Terminal Block O De Ol 0 De D Dodd GND N L1 L2 GROUND NEUTRAL WHITE LINE 1 120V BLACK lt oOoAN LINE 2 RED 120V 45 CONDITIONS OF ACURA SPA SYSTEMS LI MI TED WARRANTY ACURA SPA SYSTEMS INC 2954 RUBIDOUX BLVD e RIVERSIDE CA 92509 e FAX 951 684 6677 Acura Spa System Products are warranted to be free of defects in parts and workmanship at time of purchase by the original owner If this product is found to have a manufacturing defect Acura Spa Systems will repair or replace defective parts with new or remanufactured ones at our option at no charge to the original owner Parts used for replacement are warranted for the REMAINDER of this original limited warranty period For 18 months from date of original purchase or 2 years from date of manufacture which ever occurs first Acura Spa Systems will provide replacement of defective parts without charge subject to the following conditions 1 Owner must provide verification of the date of purchase when requesting limited warranty service sales receipt required 2 All repairs must be performed by an authorized Acura Spa Systems facility If information is needed in obtaining the location of the nearest authorized service f
38. new Spa installation Do not use an existing or used breaker GFCI All spa installations must be protected by a GFCI If your spa control box does not include an integrated GFCI then you must use a GFCI breaker per National Electrical Code requirements Note If using a GFCI type breaker on a 240 Volt 3 Wire system the breaker s neutral white wire must not be used and should be capped with a wire nut 120 240 Volt Conversion All spas are shipped configured for 240 volt 3 or 4 wire systems Please check the nameplate on the control enclosure to identify the type of system in your spa If the nameplate indicates a 120 240 Volt type system then it is possible to convert the spa to 120 volt operation 30 50 Amp Conversion Some homes may have limited power service It is possible to operate a 240 volt spa system using a 30 amp breaker Connect 240 volt power to the system as previously described then set it to operate in the low power mode To set the controller to operate in low power mode you must set system option P3 to 1 Contact your local dealer about this conversion Note Only experienced service personnel should perform conversions Improper modifications may cause damage to the control system and or the attached heater and pump motors 44 19 A Terminal Block Electrical Connections A new breaker must be used for a new Spa installation Do not use an existing breaker as its condition is unknown Breaker Capacity Po
39. nother item needs programming go to number 2 above 7 To save changes scroll to message SEND and press SET 8 To discard changes and restore previous values scroll to message CANC and press SET The menu of parameters is circular Scrolling is from first to last or from last to first When in programming mode please note that this mode will be cancelled if there is no key activity for a period of 60 consecutive seconds Programming mode is aborted and all changes will be restored to previous values On the following page is an example of how to program a filtration period When in programming mode you may program as many parameters as needed 30 14 B Example Program filtration period 2 to start at 5 45 PM Press SET amp DOWN UP SET UP UP SET DOWN SET DOWN DOWN DOWN SET Display FP1 FP2 12 00 FP2 FP1 CANC SEND Temp Explanation Start programming the display first message is Filtration Period 1 Scroll up to Filtration Period 2 Select FP2 The display shows the current FP2 start time with the hour portion flashing Increase the hour value by 1 Press UP key 4 more times or press and hold for auto repeat The hour is set the minute portion flashes Press UP 15 times or press and hold for auto repeat FP2 set to 5 45 PM and the current message is displayed again Scroll to previous message Previous message if you press SET when CANC is displayed all changes will be disc
40. nt women should limit spa and hot tub use and its water temperature to 100 F 38 C Consult your physician for further restrictions 11 12 13 14 15 RISK OF ACCIDENTAL DROWNING The use of alcoholic beverages drugs or medications before or during spa use may lead to unconsciousness with the possibility of drowning and could be fatal RISK OF ACCIDENTAL DROWNING DUE TO HYPOTHERMIA If spa water temperature falls below 98 6 F 37 C hypothermia may result Hypothermia is defined as very low body temperature and is caused by loss of body heat after prolonged immersion in cold water Its symptoms are blueness of skin color extreme fatigue slowing of heartbeat and lowering of blood pressure Hypothermia can cause coma permanent brain damage and possibly death REGULATING TEMPERATURE Temp button on SoftTouch panel a Always check water temperature with an accurate thermometer b Prolonged immersion in hot water may induce hyperthermia This occurs when the internal temperature of the body reaches a level of several degrees above the normal body temperature of 98 6 F 37 C Its symptoms are dizziness fainting drowsiness lethargy and an increase in the internal temperature of the body The effects of hyperthermia include unawareness of impending hazard failure to perceive heat failure to recognize the need to exit the spa physical inability to exit the spa fetal damage for pregnant women and unconsciousnes
41. ntrol low speed pump and ozonator 4 E2 The 24 hour time clock has 48 permanently attached trippers that can easily be set by hand without any tools Each tripper would turn low speed pump ON for thirty minutes 4 E3 Toggle switch located on left side of 24 hour time clock must be in up position Timer for the time clock to operate 10 4 F SPA SIDE CONTROL OPTIONAL Spa side control is located on spa shell could be provided with a temperature controller thermostat 4 F1 Jet Air Button located on spa side control marked jets Push jet button 4 F2 4 F3 4 F4 4 F5 once high speed pump comes on make sure pump is not surging turn thermostat knob clockwise to maximum heater light should come on except for 220V 30A and 120V 20A with thermostat know to maximum push jet button once more low speed pump will come on along with the ozonator make sure the rocker switch is in proper position Blower Air Button optional located on spa side control maybe marked warm air Push air button once to turn blower on Push air button once more to turn blower off Light Air Button optional located on spa side control marked spa light Push air button once to turn spa light on Push air button once more to turn Spa light off Booster Pump Air Button optional located on spa side control marked Booster Hi or Jet 2 Push air button once hig
42. nutes The time in minutes from starting any device after which all devices will be turned OFF and the spa put into not in use mode If you should leave the spa with a pump or light running it will be turned off after the specified time Post Use Filtration in minutes Time in minutes to perform Post Use Filtration This is the optimal time to filte the spa When you have finished using the spa that is when it needs filtration the most Press the SET key to turn everything OFF and start this cycle It is in addition to the standard filtration cycle Pressing any other key will cancel this function 33 Msg CALB SEND CANC Min 194 Def 208 Max 218 Detail This is not a time element It is one of the distinctive features of the control systems The number is internal and is indicative of what the processor sees as temperature It is used to calibrate the temperature reading Increase this value by 1 to decrease the displayed temperature by Decrease this value by 1 to increase the displayed temperature by For example if the controller is displaying a temperature 2 lower than the real temperature increase this value by 4 to get a correct reading The total range of this parameter is 10 Fahrenheit Before doing a calibration please read the warning note at the bottom of the page This menu message has no numerical value Pressing SET while it is displayed records and saves all
43. ocnnanananenennnnannrenanannrenanannrennanana 30 14 A Parameter Programming eee ites 30 14 B Programming Example sc seca cielo a a a a el 31 PARAMETER MENU LI ST mmusuneeneannnnnnna aan enanaanannanna aan nnnna aan aranana naurata nnana aaa enanaaaanannaaaaaaa 32 PROGRAMMING SYSTEM OPTI ONS nun ennea aan nnnne ana nnnnnanannanna nn nnnnaannnnanaaaannannaaaanannaaaa aaa 35 16 A User Options ainni eee taa a a e a ai a i Ca oi d aaa aa aa ta a m 36 16 B Protected Options occ ee co eta o tai ds 37 16 C Diagnostic Values ci reia ie at the A a 38 16 D Megatrol Indicator Lights 0 0 nenea neam rana 39 ERROR MESSAGES mauunnneneann nenea nnnnnnna aan nnanaanannanna aan nnana aan enanaaaannanna ana naanaaannnanaaaannanaaaaa 41 A Stas ea aie t doara Dia ov A a i i Adana ctdn ea ay Chie AA at AGEL a Anan ead ate 41 1 7 B A tenant alae adit Genin en tn ea ai 41 Toe EER eesti ter oct A E Se a 41 17D SEO a AAA awed bt a a a at 41 ME SES iaa o Sao a at a aa becas ed 42 17 F PSoC PSL PO Hi a ia 42 A deni 42 A ashen na da mica ta a aa n aa Bz A da n Dap dl A E isha aati E tien ea 42 ELECTRICAL CONNECTION INSTRUCTIONS eccccocccnccconccnnnnonccnnnnancrenananarenanannrennnnanrennanananes 43 BRANCH CIRCUIT BREAKER REQUIREMENTS ooocccccccooccccononnennnnoncnnnnnnnncnnnnnnnrrnnananrrenanananes 44 19 A Terminal Block Electrical CONNECTIONS 0c nana 45 A A IA 46 THIS PAGE INTENTIONALLY LEFT BLANK
44. on fading warping or damage during use outside of Acura Spa Systems Warranty does not cover damage during shipment All items shipped from Acura Spa Systems are shipped insured Please contact the carrier to file a claim Further all implied warranty relating to any portion of this product including any warranty or merchant ability or fitness for a particular purpose is limited to the duration of the applicable expressed warranty contained above Acura Spa Systems shall not be liable to the purchaser or to any other person for any incidental or consequential damages so the above limitation and exclusions may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state Important Notice n order to allow Acura Spa Systems to better service customer needs please provide us with model and serial numbers which are located on the front of your product Model No Serial No Date Purchased Mfg Code Dealer Name Dealer Address City State Zip R G A ACURA SPA SYSTEMS INC 2954 RUBIDOUX BLVD RIVERSIDE CA 92509 FAX 951 684 6677
45. on in minutes FP2 timer will run Duration in minutes FP3 timer will run Duration in minutes FP4 timer will run Duration in hours the Silence Timer runs Only a user may override the silence timer Note Keep the value of any timer to 0 to keep it from running Filtration timers must be programmed first one first If the FP1d first timer has duration of 0 Auto Filtration will be in effect and all 4 programmed timers will be disabled 32 Msg CLDN ECL CHCL UTO PUF Min 30 60 10 30 Def 60 180 60 20 60 Max 180 240 180 60 180 Detail Cool Down Cycle in seconds Whenever the heater is turned OFF the pump keeps running the extra seconds to even the temperature of the heater element and tr surrounding water to prevent scale buildu and premature heater failure Economy Cycle Length in minutes Tim in minutes to specify the intervals betwee spa temperature sampling when the spa i not in use During this period the spa is sleep mode Temperature is sampled at the end of the period If during the ECL the temperature reading drops more than 10 F below the set temperature the low speed pump may turn on to prevent the pipes from freezing Channel Clear in seconds Time in seconds to clear the air channel and the secondary pump s plumbing if the spa has not been used for a period of 24 hours This prevents water stagnation in the plumbing User Time Out in mi
46. or longer than 20 seconds that key will be disabled and becomes non functional After releasing the key it will be reactivated after 20 seconds This is to prevent a collapsed or defective key from locking up the system 25 12 DEVICE CONTROL GROUP There are up to 4 device keys JETS AIR AUX amp LIGHT Your spa will have at least one water pump Optionally your spa may have an air blower a second and or third pump and a spa light It may not also have a mister or a fiber optic light setup If your spa does not have a specific device please disregard the function of that device 12 A Primary Water Pump Each spa should have at least one primary water pump which is usually a dual soeed pump The low speed is used to filter the spa Also while the spa is being heated or there is an error condition the low speed circulates the water and you will not be able to turn it off The JETS key switch on the control panel is a 3 position switch Low Pump High Pump Off Each time the key is pressed the next function is executed If your primary pump is a single speed then only the high pump will be activated Two 2 LED indicators LO amp HI inform you which speed is on Note If your spa is equipped with a circulating pump it will be used for filtration and heating instead of the low speed pump 12 B Air Blower If your spa is equipped with an air blower bubbler it is activated by the AIR key This is an ON OFF key An LED will in
47. our next usage will perform a 3 hour Auto Filtration cycle before your next spa use Power Master 3002 and Hot Line 2000 are members of a family of intelligent spa control systems rich with features and can be extensively programmed to fit just about any need The rest of this manual will explain the function of each of the keys on the control panel how to change programmed settings and what each setting does It will also explain all the error messages that you may encounter and their significance and way to correct them 23 10 TIME OF DAY TOD The control system maintains a 12 hour AM PM internal real time clock TOD Time of Day The clock is based on the line frequency There is no battery backup and whenever the power is turned off TOD is no longer correct It defaults to 12 00 AM whenever the power is turned on Setting TOD is only necessary if you are going to program the filtration and silence cycles If you use the factory default settings then you do not need to set the TOD If you set TOD the controller will display time the first 10 seconds of each minute If TOD has not been set then it will not be displayed Setting TOD 1 Press and hold the TIME key for 2 seconds Current TOD will be displayed with the hour portion flashing 2 Release the TIME key 3 Using the TEMP and TIME keys scroll up and down to the desired hour Notice the AM PM led 4 When the correct hour and AM PM are displayed press the SET key to lo
48. products with serial numbers altered or removed E Products purchased outside the United States or its possessions F Commercial or industrial uses G In no event shall Acura Spa Systems be liable for loss of profits indirect consequential or incidental damages H Aquassage Boot is not warranted against discoloration cracks cuts or misuse No person agent distributor dealer service facility or company is authorized to change modify or amend the terms of this limited warranty in any manner or fashion whatsoever Except and to the extent provided in this limited warranty Acura Spa Systems makes no express warranty regarding Acura Spa Systems products l Pump seals and O Rings are only warranted for 90 days from the original date of purchase Damage to Seals and O Rings due to chemicals are not covered by this limited warranty J Individually purchased parts and products that are not assembled by Acura Spa Systems Inc are not covered by this limited warranty K Dry fired heaters chemically damaged heaters and corroded heaters are not warranted Chemicals with acid mordant substances are harmful to the heater s pump seals and other metal components and will void the warranty Water damaged P C boards improperly installed components or water damaged components will void the warranty All plastic components are warranted to be free from defects in manufacturing Plastic components are not warranted for cracking discolorati
49. s resulting in a danger of drowning WARNING The use of alcohol drugs or medications can greatly increase the risk of fatal hyperthermia in hot tubs and spas TO REDUCE THE RISK OF ELECTRICAL SHOCK Replace damaged or frayed cords immediately for cord and plug connected units only Connect only to a ground type receptacle for cord and plug connected units only Do not bury cord for cord and plug connected units only This equipment is provided with a ground fault circuit interrupter on the equipment pack within the controller door Before each use of your spa with the unit connected to the power push the test button A trip indicator should appear Push the reset button The trip indicator should disappear If the interrupter fails to operate in this manner there is a ground current flowing indicating the possibility of an electrical short Disconnect the power from the unit until the source of the breakdown has been identified and corrected Provide drainage of compartment for electrical components Before entering a spa or hot tub measure the water temperature with an accurate thermometer The tolerance of water temperature regulatory devices may vary as much as 1 F 0 5 C Persons suffering from obesity or with a medical history of heart disease low or high blood pressure circulatory system problems or diabetes should consult a physician before using a spa or hot tub Persons using medication should consult a ph
50. spa side control and the system must function properly otherwise contact your local dealer or refer to troubleshooting manual 4 B4 G F C I must be tested monthly preferably before each spa use by pushing black button IN the red button must pop OUT opening all electrical circuits By pressing red button IN red button must stay IN otherwise contact your local dealer or refer to troubleshooting manual FREEZE PROTECTING CIRCUIT 4 C1 For units with 7 day time clock RED a freeze protection switch is located on the left side of the 7 day time clock to override the 7 day time clock and let slow speed pump and heater be controlled by the thermostat SEVEN DAY TI ME CLOCK OPERATION 4 D1 The 7 day time clock is set to control the heater as well as low speed pump simultaneously The 7 day time clock provides setting each day of the week or operation may be discontinued on any day of the week Each tripper will turn heater on for a minimum of three hours The 7 day time clock has 56 permanently attached trippers that can easily be set by hand without any tools 4 D2 Toggle switch located on the left side of the 7 day clock must be in the up position Timer for the time clock to operate 4 D3 Turn temperature control to maximum 4 D4 Select the desired time on 7 day time clock to start operating low speed pump and heater TWENTY FOUR HOUR TI ME CLOCK OPERATION 4 El The 24 hour time clock is set to co
51. ted you must press the SET key to acknowledge that you the spa user are aware of the error condition and should have the proper repairs done 17 D SEoP Sensor Open Sensor Open or disconnected and the controller cannot determine the spa temperature The heater is disabled but the spa is operational The sensor must be replaced or reconnected for this message to go away 41 17 E SESH Sensor Short The sensor is shorted and is non functional Temperature cannot be determined the heater is disabled but the spa is still operational Sensor must be replaced for this message to go away 17 F PSoC PSoL PSoH Pressure Switch Open with Circulating Low or High Pump s The pressure switch is a device sensitive to pressure inside the heater manifold A pump pushing water through the manifold generates pressure in the heater manifold If a pump is running and the pressure switch does not sense any pressure then this is an indication of no water flow To prevent the heater form being turned on when there is no water running through the manifold the heater is disabled and one of these messages will be displayed indicating which pump is should be running A pressure switch error may also be indicated if the switch is out of adjustment or there is an air lock in the heater manifold Adjusting the pressure switch is best left to a trained technician An air lock may happen whenever the spa is drained and refilled with water or if the water level
52. tton Optional neces oara Aa 20 7 F 4 Booster Pump Air Button Optional mee eee eee 20 7 F 5 Gentle Pump Air Button Optional eee nenea 20 DIGITAL INTRODUCTION sai acea a au ai Gaia acne 22 ENVA HURRY iiticescicticevicssetusscnsscnvtcctesesstestensuseonenskcnsaesscssonsussensnsundseshenssedandsssacuneantuunsaanienrne 23 9 A Setting the Temperature mean ee eee 23 9 B NESE TKO iii et ci ec empatia A AA 23 TIME OF DAY TOD ii ina anida dana nadaa 24 TOAS Setting TODA AA AA la Dara ae 24 THE CONTROE PANE U si iaca aa ceai poata amana dada siveenacausemsussteexstsecdusdvessduassVensunsepnxcnand 25 12 13 14 15 16 17 18 19 20 DEVI CE CONTROL PANEL ccccceeccsseeeeennseeueeenueeeeeeeuaeeeeeenaeeueeenaaeeeeeuugeeeeeuengaeeueengsaeeeennnnees 26 122A Primary Water PUNO Ae ee a 20 A 26 122B AIP BIOW OP iei sek ce seat tee AAA aed 26 1226 Auxiliary PUMP S sisies aia di dna a Bit a n Biata af Bu a pl AA dara ul 26 12D Spa Lightiii A Second lected ad ad oa 26 12 E Summary of Device Functions ceeee eee nenea anna 27 STATUS CONTROL GROUP mmeasunnnneannnnnnna aan nnanaaaannannaaannanna anna emana aaa nnanaaaannannaaaanaanaaaa aaa 28 13 A The Temp Key atada a ia al a dine a A a a n A ia 28 13 B The Time Key cai aaa a a Dc a Po pda a aia 28 13 ThE Set Re coc cioc re tn aa at a e i ca e de e aim a ae a a a 29 PROGRAMMING THE PM 3002 amp HL2000 cccocooooccccononcccnonon
53. would turn low speed pump ON for thirty minutes 5 E3 Toggle switch located on left side of 25 hour time clock must be in up position Timer for the time clock to operate 13 5 F SPA SIDE CONTROL OPTIONAL Spa side control is located on spa shell could be provided with a temperature controller thermostat 5 F1 Jet Air Button located on spa side control marked jets Push jet button 5 F2 5 F3 5 F4 5 F5 once high speed pump comes on make sure pump is not surging turn thermostat knob clockwise to maximum heater light should come on except for 220V 30A and 120V 20A with thermostat know to maximum push jet button once more low speed pump will come on along with the ozonator make sure the rocker switch is in proper position Blower Air Button optional located on spa side control maybe marked warm air Push air button once to turn blower on Push air button once more to turn blower off Light Air Button optional located on spa side control marked spa light Push air button once to turn spa light on Push air button once more to turn spa light off Booster Pump Air Button optional located on spa side control marked Booster Hi or Jet 2 Push air button once high speed pump will come on Push air button once more to turn high speed pump off Gentle Pump Air Button optional located on spa side control mark
54. ysician before using a spa or hot tub Some medications may induce drowsiness while other medications may affect heart rate blood pressure and circulation The electrical supply for this product must include a suitably rated switch or circuit breaker to open all ungrounded supply conductors to comply with 2 16 17 18 Section 422 20 of National Electric Code ANSI NFPA 70 1987 a disconnecting means must be readily accessible to the tub occupant but installed at least 5 feet 1 5 meters from the tub PRESSURE WIRE CONNECTOR for all units A pressure wire connector is provided in the control box inside the unit to permit connection of a minimum No 8 AWG 8 4 mm solid copper bonding conductor between this point and any metal equipment metal enclosures of electrical equipment metal water pipe or conduit within 5 feet 1 5 meters of the unit as needed to comply with local requirements FOR UNITS WITH G F C I Ground Fault Circuit Interrupter The G F C is located on the right hand side of the upper front panel of the Powertronics control box It must be tested before each use FOR UNITS WITH GAS HEATERS Do not install the gas heaters indoors SAVE THESE INSTRUCTIONS 2 A 2 B 2 C INSTALLATION I NSTRUCTI ONS ELECTRICAL I NSTALLATI ON All electrical installations must be done by a licensed electrician and must be wired per the National Electric Code as well as all local codes and regulations INSTALLA