Home
SquareLED ENERGY 7x12W RGBAW + UV (6-in-1)
Contents
1. 1 Press the ENTER button in BAT menu then enter to the Battery output setting 2 Press the UP DOWN button to select HIGH MIDDLE LOW 3 Press the ENTER button to escape and save 7 6 9 DMXsignal selection setting 1 Press the ENTER button in SIGN menu then enter to the DMX signal selection setting 2 Press the UP DOWN button to select 2 4G CABLE 3 Press the ENTER button to escape and save 7 6 10 Wireless set 1 Press the ENTER button in WIRE menu then enter to the wireless set 2 RESET the Analog process of press the button on again after wireless module off 3 KEY similar as the build out kep 7 6 11 CUSTOM COLOR SETTING Press the ENTER button CTST menu then enter to the custom color setting Press the UP DOWN select 701 CT10 Press the UP DOWN button to select 1 255 numerical value Press the ENTER button to escape and save 1 2 2 3 7 6 12 AUTORUN SELF PROGRAM RUN 1 Press the ENTER button in AUTO menu then enter to the auto run self program run 2 Press the UP DOWN button to select 01 05 AUTO SPEED 9 01 CHASEO3 3 Press the ENTER button to start running ssi Manual ENERGY 7x12W RGBAW UV 6 in 1 713 EDIT SELF PROGRAM 1 Press the ENTER button in PROG menu then enter to the edit self program 2 Press the UP DOWN but
2. the brightness declines Check whether the POW is in over temperature protection situation or not if obviously yes please take measures for ventilation Noted only professional persons can do as above Das Lichttechnikhaus Vertriebs GmbH Rudolf Diesel Str 3 D 89312 G nzburg Telefon 49 0 8221 207 98 0 Fax 49 0 8221 207 98 69 E Mail info lth gmbh de Web www Ith gmbh de
3. UV UV to 71 75 AUTO 3 R G R G R B R B B G B G 76 80 AUTO 4 R G B W R G B W AUTO 5 Rainbow effect BG B G G GR GR G R R RB RB R B 86 90 CHASE 1 91 95 CHASE2 96 100 CHASE3 101 110 Reserved R 111 115 G 116 120 B 121 125 A 126 130 W 131 135 UV 136 140 YELLOW 141 145 PINK 146 150 CYAN 151 155 ORANGE 156 160 VIOLET 161 165 GOLDEN 166 170 2700K 171 175 3200K 176 180 4000K 181 185 5500K 186 190 6500K 191 195 RGBW 196 200 201 255 Reserved CH10 0 255 0 255 S speed of AUTO fast to slowXiwhen AUTO1 AUTOS effective 81 85 111 200 Manual ENERGY 7x12W RGBAW UV 6 1 4CH 5CH 6CH 7CH 9CH 12CH VALUE FUNCTION 0 10 No effect 11 Blue Blue full Red Green 0 step 12 50 Red 0 Green gt up Blue full proportional 51 Light Blue Red 0 Green full Blue full step 52 90 Red 0 Green full Blue gt down proportional CH11 91 Green Red 0 Green full Blue 0 step RGB 92 130 Red gt up Green full Blue 0 proportional CH5 color me 131 Yellow Red full Green full Blue 0 step xing 132 170 Red full Green gt down Blue 0 proportional 171 Red Red full Green 0 Blue 0 step 172 210 Red full Green 0 Blue gt up
4. L UI 9 AN MV9DY MZLXZ ADYIN3 jenueyy sn quareled gt Manual ENERGY 7x12W RGBAW UV 6 in 1 1 Summarization Summarize Thank you for purchasing our ENERGY 7x12W RGBAW UV 6 in 1 lighting Please read these instructions carefully before begin and operate the fixtures according to these instructions to avoid any possible damages and accidents causes by misusage Products introduction Energy 7x12W RGBW UV 6in1 light uses casting aluminum housing designed a fashion of hydrodynamic form Appearance shows It adopts high power 6 in 1 LED which refers to single LED is made of R G B A W UV 6 IN 1 LED And long life span low consumption good color mixing effect and high brightness are the most prominent features Each kind of LED can be independently dimmed The built in program includes dimming strobe eotic gradual change fading and so on It uses power switch performs low weight and consumption stable capability and long life International standard DMX 512 signal is requested Packing list 1x SquareLED ENERGY 7x12W RGBAW UV 6 in 1 1x DMX signal cable 1x Power cable the User Manual Warranty Card 2 Safety Instruction Safety Notes Enquire the skilled people before any repair Always make sure disconnect from the power source before setting up serving and moving Avoid direct eye exposure to the fixture when it is on Safety instruction e Make sure the power supply
5. proportional 211 Magenta Red full Green 0 Blue full step 212 250 Red gt down Green 0 Blue full proportional 251 255 Blue Red 0 Green 0 Blue full step 0 10 Use the dimmer mode which menu had set up 11 20 Linear curve 21 30 Square law curve 31 40 Inverse square law curve _ _ _ _ 41 50 S curve 51 60 Linear curve and smooth 61 70 Square law curve and smooth 71 80 Inverse square law curve and smooth 81 90 5 and smooth 91 255 Use the dimmer mode which menu had set up 5 Display Operation OLE MENU access the menu or return to a previous menu option UP menu selection or parameter increments DOWN menu selection or parameters decrease ENTER select the current menu option ee Manual ENERGY 7x12W RGBAW UV 6 in 1 Menu Tree Tab Level 1 Level 2 Level 3 Level 4 ADDR Address 001 512 0 255 STAT Static control R 0 255 0 255 0 255 0 255 G B A 0 255 UV 0 255 SHUT 0 255 PRSC Preset color NONE R G B A W UV YELLOW PINK CYAN ORANG E VIOLET GOLDEN 2700K 3200K 4000K 5500K 6 500K RGBW SET Set CAL Calibration R Red 0 255 G Green 0 255 B Blue 0 255 A 0 255 W 0 255 UV 0 255 USE YES NO CHMD Channel mode 12CH 9CH 7CH 6CH 5CH 4CH DIM
6. setting 2 Press the UP DOWN button to select 12CH 9CH 7CH 6CH 5CH 4CH 3 Press the ENTER button to escape and save Manual ENERGY 7x12W RGBAW UV 6 in 1 7 5 DIMMING MODE SETTING 1 Press the ENTER button in DIM menu then enter to the dimming mode setting 2 Press the UP DOWN button to select LIN SQR ISQR SCUR LIN SQR ISQR Xand SCUR 3 Press the ENTER button to escape and save Illustrations When setting LIN SQR ISQR and SCUR in DIM menu there will be added a little delay dimming effect for smooth Dimming curve Linear curve Square law curve 3 2 5 O DMX DMX Inverse Square law curve S curve 5 5 2 2 gt DMX 76 DISPLAY SETTING 1 Press the ENTER button in DISY menu then enter to the display setting 2 Press the UP DOWN button to select ON 2 MINITES OFF 3 Press the ENTER button to escape and save Manual ENERGY 7x12W RGBAW UV 6 in 1 77 AUTO LOCK KEY SETTING 1 Press the ENTER button in LOCK menu then enter auto lock key setting 2 Press the UP DOWN button to select YES NO 3 Press the ENTER button to escape and save Instructions When set to YES it will lock automatically after two minutes to prevent acci dental triggering flood flushing and then press any key keep 10 seconds to unlock 78 Battery output setting
7. voltage are consistent with this lights Ensure the use of voltage is in the range of the request technical parameter e Before the installation please check the light s fasteners and mechanical structure have been received in good condition and appear no damage This light is designed for indoor use working temperature is lower than 40 degree The fixtures maybe mounted in any position provided there is adequate room for ventilation Make sure there are no inflammable and explosive items ornaments in 0 5 meters away e Yellow green cabling earthling safety no flicker when the fixture is working on EEE Manual ENERGY 7x12W RGBAW UV 6 in 1 3 Main Function Input voltage AC 100V 264V 47 63HZ Consume 90W Lamp Type 12W LED 6 in 1 R G A W UV 7PCS Life span 50000 100000hours PWM Dimmer 1500HZ 16666 grades Control Signal DMX512 Control mode stand alone sound activated Channel 12CH 9CH 7CH 6CH 5CH 4CH Function Effect dimmer strobe gradual change Touch buttons automatic lock key Built in temperature control measurement function when LED work overheated intelligent reduce LED output power current power output can be viewed Cooling mode Natural Convection built in lithium battery compatible with Swedish wireless DMX module Battery Capacity 25 91 6 6Ah Charging time 4 hours full light Duration 3 hours Anti electricity int
8. Dimming mode LIN linear SQR square law ISQR inverse square law SCUR S curve LIN linear smooth SOR square law smooth ISOR inver se square law smooth SCUR S curve smooth DISY Display set ON Permanent on 2MIN 2 minutes off LOCK Key 2 minutes YES NO lock BAT battery output HIGH high MID LOW SINUM sial 2 4G wirelsee CABL Cable selection Manual ENERGY 7x12W RGBAW UV 6 in 1 Tab Level 1 Level 2 Level 3 Level 4 WIRE Wireless set REST reset YES NO KEY 2 color 101 R 0 255 G 0 255 B 0 255 A 0 255 0 255 UV 0 255 710 AUTO Auto 01 0 255 02 0 255 03 0 255 04 0 255 05 0 255 CHS1 RUN CHS2 RUN CHS3 RUN PROG Program CHS1 Chase 1 5601 Scene 1 R 0 255 G 0 255 B 0 255 A 0 255 W 0 255 UV 0 255 SHUT 0 255 AUTO 01 05 ATSP 0 255 S TIME 0 255 S WAIT 0 25 5 5 USE YES NO SC20 Scene 20 53 3 INFO Information a POW Power reduction 100 80 50 BAT 0 10 STL Setting load YES NO PR L Program load YES NO SEND Send VES NO EEE Manual ENERGY 7x12W RGBAW UV 6 in 1 7 Instruction When enter to the position displayed on the LED the light will automatically set as master and send data to external Other
9. Manual ENERGY 7x12W RGBAW UV 6 in 1 7 16 PROG SELF PROGRAMMING PARAMETER RESET 1 Press the ENTER button in PR L menu then enter to the PROG self programming parameter reset 2 Press the UP DOWN button to select YES 3 Press the ENTER button to escape and save 7 17 LIGHTING PARAMETER DOWNLOADING EACH OTHER VIA DMX CABLE 1 Press the ENTER button in SEND menu then enter to sending parameter to other lightings 2 Press the UP DOWN button to select YES 3 Press the ENTER button to confirm sending Illustrations 1 Please disconnect the connection of projector and DMX console before sending the parameter 2 The information of ADDR CAL can t be sent can t be downloaded each other 3 There will be an automatic reset of the other projectors after receiving parameter correctly 8 Instruction for compatible Sweden DMX wireless module 1 There are 4 modes compatible Sweden receive mode green indicator compatible Sweden transmit mode blue indicator normal mode yellow indicator custom mode red indicator 2 After RESET and then press KEY to switch above modes select needed mode and press KEY one second to confirm and save it 3 Under compatible Sweden DMX receive mode press KEY 3 seconds to delete matching between light and transmitter 4 Under compatible Sweden DMX transmit mode press KEY to match receive mode press 3 seconds will delete ma
10. ension 1 5KV Insulation Resistance gt 2MQ Size 287 3 x 270 1 x 166 0 Net Weight 5 2 kg Beam Angle 15 25 45 Optional Manual ENERGY 7x12W RGBAW UV 6 in 1 4 Outside Size Picture 5 DMX Control Function DMX Channels ACH 5CH 6CH 7CH 9CH 12CH VALUE FUNCTION CH1 CH1 CH1 CH1 0 255 Dimming all CH1 CH1 CH2 CH2 CH2 0 255 Red CH2 CH2 CH3 CH3 0 255 Green CH3 CH3 CH4 CHA CH4 0 255 Blue CH2 CH4 CH5 CH5 CH5 0 255 Amber CH4 CH3 CH5 CH6 CH6 CH6 0 255 White CH4 CH6 CH7 CH7 CH7 0 255 UV 0 5 No strobe 6 20 Random burst strobe slow to fast 21 60 Normal strobe slow to fast 61 100 Electronic Sinewave slow to fast 101 140 Random Strobe slow to fast 141 180 Opening pulse slow to fast 181 220 Closing pulse slow to fast 221 255 Electronic Squarewave slow to fast BE we Manual ENERGY 7x12W RGBAW UV 6 in 1 ACH 5CH 6CH 7CH 9CH 12CH VALUE FUNCTION 0 10 No effect 11 15 01 16 20 102 21 25 103 26 30 104 31 35 105 36 40 106 41 45 07 46 50 108 51 55 09 56 60 110 CH9 6165 AUTO1 R G B A W UV RG RB GB AW WUV AUV He 66 70 AUTO2 R R G G B B A A W W
11. fixtures can receive this data and will synchronously running without manually set as slave When power cycle it will jump to the position and running again 71 DMX ADDRESS SETTING 1 Press the ENTER button in ADDR menu then enter to the DMX address setting 2 Press the UP DOWN button to select 1 512 numerical value 3 Press the ENTER button to escape and save 7 2 STATIC SETTING 1 Press the ENTER button in STAT menu then enter to the static setting 2 Press the UP DOWN button to select RED GREEN BLUE WHITE PRSC 3 Press the UP DOWN button to set up the 0 255 numerical value 4 Press the ENTER button to escape and save 73 COLOR CAST CALIBRATION SETTING 1 Press the ENTER button in CAL menu then enter to the color cast calibration setting 2 Press the UP DOWN button to select RED GREEN BLUE UV 3 Press the UP DOWN button to set up the 0 255 numerical value 4 On the USE interface pressing YES button means valid NO means invalid 5 Press the ENTER button to escape and save Illustrations When pressing the YES button which means valid on the USE interface the actual output value of RED GREEN BLUE UV is output in accordance with the percentage which the color cast calibration value divides 255 74 CHANNEL MODE SETTING 1 Press the ENTER button in CHMD menu then enter to the channel mode
12. s always advisable to connect a DMX terminal Resistance 120 Ohm 1 4 W between 2 DMX and PIN 3 DMX of the last fixture The Conversion between 3 pin and 5 pin XLR If the output cable of DMX512 controller is the 5PIN please use 1pc 5PIN to 3PIN cable 3 Pin XLR to 5 Pin XLR Conversion ene Not Used Do Not Use Et Manual ENERGY 7x12W RGBAW UV 6 in 1 10 Connecting picture Light connecting picture 11 Trouble Shooting Problem Checking Way Check the power connection is correct or not Please detect the voltage The lightin g can t be Power supply is damaged or incorrect connected Call a qualified personnel to started normally fx it Connection of control board is not correct Call a qualified personnel to fix it Please check the DMX connector and the power connection is connected cor rectly or not It means having signal if it shows twinkling of the decimal point which in the lower right corner of the screen when exiting the screen saver Please check the DMX address setting of lighting is correct or not Check CHMD setting is correct or not Check SIGN setting is correct or not Please check whether the DMX line is near to the high voltage wire or not In that case it will damage or interfere the DMX electric circuit Out of console s control beam appears dim Check whether the CAL is started or not and the set value is too small
13. tched mode 5 Working in normal mode indicator has 7 colors for option when light and transmitter indicator are in the same color can receive and transmit data 6 User defined function is not available 7 Notice compatible Sweden DMX mode in this lights has complete data for sending and receiving but transmit function is not available here Manual ENERGY 7x12W RGBAW UV 6 1 9 Operating Control Instruction Master Slave When the fixtures work in master mode it will send out the signal for the slave synchronous with it To avoid the host signal and DMX512 signals interfere with each other should cut off the DMX512 signals The signal lines are longer than 60 meters 20 lamps should increase a signal amplifier 10 XLR cable connecting XLR cable The standard way of connecting the XLR is one end connects to the male plug and the other end connects to the female As bellow pin 1 ground pin 2 negative signal pin 3 positive signal XLR Male Socket XLR Female Socket XLR Pin Configuration 1 Ground 2Cold 2Cold 1 Ground Fin 1 Ground Pin 2 Data Compliment negative i 3 Hot 3 Hot Pin 3 Data True positive Le 3 COMMON Noted In order to avoid failures and interference signal transmission we connecta resistance1200 1 4W at the end of the DMX connecting as below Termination reduces signal errors and avoids signal transmission problems and interference It i
14. ton to select 5 01 CHASEO3 3 Press the ENTER button for confirmation and enter to the next menu 4 Press the UP DOWN button to select SCENEO1 SCENE20 5 Press the ENTER button for confirmation and enter to the next menu 6 Then press the UP DOWN button to select SHUT TIME WAIT USE 7 Press the UP DOWN button to set up the parameter which are needed 8 Press the ENTER button t o escape and save Illustrations When USE is set to be NO or the parameter of TIME is 0 it will not run this scene When WAIT is set to be FADE time the running process isas the following chart showing 7 14 CHECK THE LIGHTING INFORMATION 1 Press the ENTER button in INFO menu then enter to the checking the lighting information 2 SOFT button is for software version information 3 POW button is for the current information of power reduction It is 100 output in normal conditions but 80 or 50 output in over temperature protection situation 4 BAT Remaining battery power from 0 10 7 15 LIGHTING SETTING PARAMETER RESET 1 Press the ENTER button in ST L menu then enter to the lighting setting parameter reset 2 Press the UP DOWN button to select YES 3 Press the ENTER button to escape and save Illustrations ADDR CTST and PROG are not reset the others reset to the underlined value of the word