Home
Model VJ77 PC-based Parameters Setting Tool
Contents
1. JUXTA VJ series 9 pin D sub female connectors gt for IBM PC AT compatible models g I FOSS 1 Personal computer with VJ77 installed IM 77J01J77 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt lt Chapter 2 Setup gt 2 4 2 4 Setting the Communication Port This section describes how to set the communication port to connect a JUXTA instrument to the personal computer VJ77 The communication port can be set choosing from COM1 to COM16 when any one of the following dialog boxes is displayed e Parameter Setting Menu dialog box e Menu dialog box e Data Uploaded from JUXTA dialog box e Data Read from a File dialog box e Program Setting Menu dialog box e Program Editor dialog box Step 1 Start VJ77 refer to Section 3 1 In the Parameter Program Setting Menu dialog box select Parameter Setting then click OK Step 2 From the menu bar click Communication Settings then Serial Port Click the communication port you wish to set from COM1 to COM16 The port currently selected is checked in the menu File F ESSE Help Serial Port S kj v COM sna GOMA CON Goh COMS COMB COM IM 77J01377 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt lt Chapter 3 Basic Operation gt 3 1 3 Basic Operation This chapter describes basic operation and identifies the main dialog boxes of VJ77 3 1 Starting VJ77 Step1 From the Start menu choose commands in the following sequence Po
2. User s JURI Manual Model VJ77 PC based Parameters Setting Tool IM 77J01J77 01E vigilantplant YOKOGAWA IM 77J01J577 01E l 5th Edition Yokogawa Electric Corporation lt Toc gt lt Ind gt lt Rev gt lt Introduction gt l Introduction This instruction manual describes the functions and operation of the Model VJ77 PC based Parameters Setting Tool E Configuation of This Manual This manual consists of 12 chapters 6 Chapter 1 VJ77 PC based Parameters Setting Tool Gives an overview of VJ77 and describes its functions and the operating environment 6 Chapter 2 Setup Describes how to setup the hardware and software required to use VJ77 6 Chapter 3 Basic Operation Describes the basic operation and main windows of VJ77 6 Chapter 4 Setting Parameters Describes how to set parameters of JUXTA instruments 6 Chapter 5 Setting a Program Describes how to set a program for JUXTA computing units 6 Chapter 6 Uploading and Downloading Data from to JUXTA Describes how to upload parameter or program data inside JUXTA instruments from VJ77 and how to download the data to JUXTA instruments 6 Chapter 7 Saving Data Describes how to save parameter or program data on a disk 6 Chapter 8 Printing Data Describes how to print parameter or program data 6 Chapter 9 Monitoring Input Output Values Describes how to monitor the I O values of JUXTA instruments and how to view the result of self diag
3. In Windows Vista Windows 7 do not save VJ77 user file in Program Files folder The VJ77 will not work properly Also if VJ77 user file save directory is set in Program Files folder on Windows XP personal computer do not upgrade its OS to Windows Vista Windows 7 e Before installing VJ77 Setting Software quit all running applications e Avoid entering just the drive as the installation location such as Ci Enter the full directory path e When reinstalling VJ77 uninstall the installed VJ77 first and then reinstall VJ77 Step 1 Insert the CD of VJ77 into the CD ROM drive Step 2 The following screen appears The following example is for Windows XP Double click VJ77_E Note For a PC on which a English OS is installed be sure to open VJ77_E virriey 5 Oj x File Edit View Favorites Tools Help a File and Folder Tasks CJ E Publish this Folder to the web E Share this Folder Other Places A s My Computer Oj My Documents ig Shared Documents a My Network Places Details A WITT E CD Drive File System CDFS Free Space 0 bytes Total Size 6 94 MB IM 77J01J77 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt lt Chapter 2 Setup gt 2 2 Step 3 Double click setup exe Follow the instructions appearing in the dialog boxes fe VITI E E 10 x File Edit View Favorites Tools Help Pi Back gt r pi a Search gt Folders E Address i viF7_E Y Go ee
4. Save to file Download to JUSTA Print Step 2 The Starts communication Press OK button if ready appears Click OK to start downloading Step3 The Now Communicating dialog box appears and shows the progress of down loading When the download is complete the Downloading to JUXTA com pleted message appears Ay CAUTION Data in the Comment cells are not downloaded Acreated program downloaded to the JUXTA computing unit other than programmable computing units is not downloaded and only constants are downloaded TIP The Error found during command check Do you want to see the error content appears if the program contains any syntax error or other kind of error Clicking Yes opens the Com mand Check Error dialog box shown in Section 5 2 2 Or clicking No downloads the data containing the program with syntax errors In this case each illegal program code will overwrite the corresponding current code or be written as NOP and the Check Download ing to JUXTA dialog box appears IM 77J01J77 01E 5th Edition Feb 28 2011 00 SS SAN x Page S lt Toc gt lt Ind gt lt Chapter 7 Saving Data gt 7 1 7 Saving Data This chapter describes how to save to disk the parameter program data that was uploaded or you created Parameter data and program data will be saved with the following filename extensions e Parameter data files 7pa e Program data files 7pr File names
5. Commands including buttons in a dialog box or window and menu commands are written in boldface Dialog box elements such as text boxes list boxes option buttons and check boxes are also written in bold face and refer to their exact labels Characters to be typed by the user via keyboard are written in monotype font A WARNING Usage Parameter Setting Menu dialog box Gantt view document window print preview Click OK Click Options From the File menu choose Exit Select the Spaces check box Click to clear the Bookmarks check box In the Font box type or select the font you want to use In the File Name box enter a file name Type JUXTA in the Model box Indicates that operating the hardware or software in a particular manner may damage it or result in a system failure AN CAUTION Draws attention to information that is essential for understanding the operation and or features of the product TIP Gives additional information to complement the present topic See Also Gives reference locations for further information on the topic IM 77J01J77 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt lt Rev gt lt Introduction gt V E illustrations in This Document 1 Illustrations and figures presenting this product or its functions in this manual may not be exactly the same as the actual product or functions so as to simplify understanding 2 Figures and illustration
6. Saving Data IM 77J01J77 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt lt Chapter 6 Uploading and Downloading Data from to JUXTA gt 6 4 6 1 3 Uploading Program Data from JUXTA Instrument Step 1 Inthe Parameter Program Setting Menu dialog box select Program Setting then click OK If a password is set enter the password in the Password Entry dialog box and click OK Step 2 The Program Setting Menu dialog box appears Select Upload Program Data from JUXTA and click OK Program Setting Menu _ _ i OK t New Cancel eee C Read Program Data from a File Step 3 The Starts communication Press OK button if ready message appears Click OK to start uploading Step 4 The Program Editor dialog box appears In this dialog box programs can be modified and models can be changed Program Editor MODEL jmxs e Model Selection STEP PROGRAM Comment al Close G1 Load input 1 Load CONST H1 Moving average Store the result in Yi l eters ean Command Check Save to file Download to JUSTA Print ok New Style _J Old Style k te MAS C Mes Cancel O MADE C MAD C MsT E C MAT e HE I Ms C ves Fx i WAT x Ween E GJA esi IM 77J01377 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt lt Chapter 6 Uploading and Downloading Data from to JUXTA gt 6 5 Ay CAUTION Only constants CONST are displayed for a computing u
7. 4 Tab labels 9 Scroll button 0 6000 VUL S 7 SELECT RANGE ALTO H RESET 100 0 GHH MPUTI L RNG 1 000 HUTI H AHG 5 000 Muas eM Title bar Shows the name of the window or dialog box displayed as is usual for Windows applications Menu bar As is usual for Windows applications the menu bar is displayed below the title bar of a window Each menu name contains the related commands Option button Used to select one item from alternatives as is usual for Windows applications Tab labels As is usual for Windows applications some dialog boxes have more than one page with a tab often referred to as tabbed pages Parameter table Shows a list of the parameter data values of the connected JUXTA instrument Selected cell The cell currently selected by double clicking is displayed with thicker borders Text box Used to enter a value to be set In the SET dialog box double clicking the parameter you wish to set makes the text box available for the entry of a parameter value IM 77J01J77 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt lt Chapter 3 Basic Operation gt 3 4 8 Command buttons Carry out the corresponding functions when clicked OK Makes the operation take effect and displays the next dialog box Cancel Discards the operation and displays the previous dialog box Close Closes the dialog box WRITE Writes the data entered in the text box to the JUXTA instrument
8. 9 Scroll buttons Used to bring hidden part of the parameter table into view IM 77J01J77 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt lt Chapter 3 Basic Operation gt 3 4 Basic Operation 3 4 1 Operation Using a Mouse E Menu bar operation 1 Click an item on the menu bar to open a menu 2 From the menu click the command you wish to execute E Selecting an item 1 Click the command you wish to select E Data entry operation 3 9 1 Toenter data in the SET dialog box double click the data cell of the parameter you vvish to change The text box in the bottom of the SET dialog box is selected Then enter the data in the text box FARAWETER ee T TAG NO TAG NO 2 COMMENTI COMMENT2 LINEARIZE OFF LOW CUT I 0 6000 INP TYPE 0 VOLTS DIT SELECT RANGE AUTO 2 After entering data in the text box click WRITE The data is written to the JUXTA instrument There are two types of data entry with text boxes e Text boxes that require a numeral to be typed as shown below WRITE e Text boxes that require a choice from a list as shown below FMOUDBUS ATO MODBUS ASCII WRITE PELINE WITH SUM Ay CAUTION If you click Close without clicking WRITE any data typed in the text box will not be written to the JUXTA instrument Be sure to click WRITE after you enter data IM 77J01J77 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt l
9. While setting parameters the communication cable was disconnected Remedy and connected to another JUXTA instrument of a different model Restart communication from the VJ77 window or restart VJ77 and start communication from the beginning IM 77J01J77 01E 5th Edition Feb 28 2011 00 SS SAN x Page S lt Toc gt lt Ind gt lt Chapter 12 Appendix gt 12 1 12 Appendix 12 1 Setting the Password This section describes how to set a password to VJ77 Password protection is a security function that prevents parameter and program settings in JUXTA instruments from being modified by an unauthorized person Step 1 Start VJ77 Step 2 From the menu bar click Password then Set MODELI NewFile Fileje Communication setinge Seen Help Parameter Program Setting Ma HET qese f Parameter Setting C Program Setting Step3 The Set Change Password dialog box appears Type a password 4 digit nu meral in the New password box and type the same numbers in the New Pass word Confirm box S et Change Password Enter password 4 digit Mumeral E New Password E E ance New Password Contirn E Step 4 Click OK G Password has been set IM 77J01J77 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt lt Chapter 12 Appendix gt 12 2 12 2 Changing the Password This section describes how to change the password already set to VJ77 Step 1 Start VJ77 Step 2 From the menu b
10. the same value to the opposite polarity Error measured value reference value span x100 3 96 4 00 16 x100 0 25 In this example the output level read in step 1 showed the 0 25 deviation Hence you should type 0 25 in the text box and click WRITE Check that the reading of the calibrator is within the range of rated accuracy and quit the proce dure ADJUST TEST PARAMETER ZERO KOJI tii o Ww SPAN ACJ TM Old Y In the same way correct the 100 output level Step 3 To correct the 100 output level double click the P13 OUT1 100 data cell and follow steps 1 to 2 IM 77J01J77 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt lt Chapter 10 Adjusting JUXTA Instruments gt 10 4 10 4 Setting Wire Resistance Compensation If the input wiring resistance is causing a significant error after the wiring to the field device has been completed you can compensate for the wiring resistance with the following procedure Step 1 Change the wiring connections in the field as shown at the bottom of this page Step 2 When the input is stable double click the P01 WIRING R data cell fren om EE E A A e E SFAH aL CUTI On 000 TI bite io IUT Of 100 E DUT IDUS LO S Cancel Forced Output EXEC UTE I WRITE Step 3 Click the arrow next to the text box Choose EXECUTE from the list and click WRITE The wiring resistance is then compensa
11. click the cell of the parameter you wish to update To stop the periodic upload for updating of the DISPLAY2 page click READ STOP The button label changes from READ STOP to READ START To resume the periodic upload for updating click READ START IM 77J01377 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt lt Chapter 10 Adjusting JUXTA Instruments gt 10 1 10 Adjusting JUXTA Instruments This chapter describes how to adjust the input output of JUXTA instruments and the settings of the wiring resistance compensation These adjustments are made via the ADJUST dialog box 10 1 Opening the Adjusting Dialog Box 6 Preparation Connect the JUXTA instrument to the personal computer then turn on the power to the instrument Step 1 Start VJ77 In the Parameter Program Setting Menu dialog box select Param eter Setting and click OK If a password has been set enter the password in the Password Entry dialog box and click OK Step 2 The Parameter Setting Menu dialog box appears Select Set and click OK Step 3 The Starts communication Press OK button if ready message appears Click OK Step 4 The Menu dialog box appears Select ADJUST and click OK MODEL WIH Ok E Cancel C DISPLAY Step 5 The ADJUST dialog box appears AUST TEST IM 77J01J77 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt lt Chapter 10 Adjusting JUXTA Instruments gt 10 2 10 2 Performing Fine Adjustmen
12. data in the cell is updated from 1 to 10 10 0000 WRITE D23 JINFUTI H_RNMG 5 000 M Ose GUTI DR DIRECT 10 0000 WRITE D18 JIN RESIST 100 0 OHM Ay CAUTION After you click WRITE the data value shown in the data cell may be different from the value you entered in the text box This is because the JUXTA instrument has limits for some of its parameters and if the entered value is outside the limits the instrument automatically sets the parameter to the nearest limit value IM 77J01J77 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt lt Chapter 4 Setting Parameters gt 4 4 Step 4 Inthe same way as Step 1 to Step 3 set the 100 value of the input range by double clicking the data cell of D23 INPUT1 H_RNG Step 5 Enter 10in the text box and click WRITE The data is written to the JUXTA instrument and the display data is updated from 5 to 10 The input range of the connected JUXTA instrument has now been changed from 1 to 5 V DC to 10 to 10 V DC 4 2 2 Notes on Setting Parameters The input range output range of a JUXTA instrument can be set in two ways depending on the model of the instrument 1 Models for which 0 and 100 values of the range are set The high range limit and low range limit are represented as L_RNG and H_RNG as in INPUT L_RNG and INPUT H_RNG 2 Models for which the span value and span of the range are set The 0 value and span are represented as ZERO and SPA
13. gt 4 0 N N O Q D 5 r lt Parameter Setting Menu Menu DISPLAY Displays I O values etc Upload parameter data from JUXTA Read parameter data from a file 199195 Program Setting Menu Program Editor Upload program data from JUXTA PROGRAM CONST Create a program Set constants Read program data from a file ay mea EA Extends to the next display only in an online state Extends to the next display regardless of online offline status Online refers to a state in which JUXTA instrument and the personal computer VJ77 are connected via a dedicated adapter The Password Entry dialog box appears if a password is set IM 77J01J77 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt lt Chapter 3 Basic Operation gt 3 9 3 6 Main Dialog Boxes and Their Functions 3 6 1 DISPLAY Dialog Box This dialog box shows the input output values of the JUXTA instrument and the results of self diagnosis ES 6 001 38 OUTPUT 25 0 ALNI STATUS E See Also For more information about the DISPLAY dialog box see Chapter 9 Monitoring VO Val ues 3 6 2 SET Dialog Box This dialog box is used to set various parameters of the JUXTA instrument 5 000 DIRECT See Also For more information about the SET dialog box see Chapter 4 Setting Parameters IM 77J01J77 01E 5th Edi
14. in the entry box and click OK Slots are numbered from 1 to 16 from the left to right of the D series nest Step6 The Menu dialog box appears Select SET and click OK The SET dialog box appears You can set parameters here COMMENT INEARIZE CY CUT PRERE ELECT RANGE mls DO e ojaja GJE mn E ne 4 aj T Z J T 0 a rp MPUTT H_RNG DUTI DR IM 77J01J77 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt lt Chapter 4 Setting Parameters gt 4 3 4 2 Setting Parameters This section describes how to input individual parameter data and write the data to the JUXTA instrument from the parameter setting display the SET dialog box 4 2 1 Entering a Setting Value and Writing It to JUXTA The following describes how to change the input range of JUXTA VJH7 isolator unit with reference to the example of changing the input range from 1 to 5 V DC to 10 to 10 V DC Step 1 Inthe SET dialog box open the SET I O page Then double click the data cell of parameter D22 INPUT1 L_RNG SETIMO SETIALM SETICOM PARAMETER DATA i 001 TAG NO 1 Close WOLTS AUTO 100 0 OHM INPUTI L_RNG v INPUT1 H_RNG 5 000 V DIRECT 1 000 WRITE a OFF 0 6000 Step 2 The text box at the bottom becomes available showing the current setting WRITE Step 3 In the text box type 10and click WRITE The new data is written to the JUXTA instrument and the display
15. 1 80 4158 6000 Fax 91 80 2852 1442 YOKOGAWA CHINA CO LTD 3F TowerD Cartelo Crocodile Building No 568 West Tianshan Road Shanghai 200335 CHINA Phone 86 21 62396262 Fax 86 21 62387866 Aug 10 Printed in Korea
16. 1E 5th Edition Feb 28 2011 00 YOKOGAWA Q YOKOGAWA ELECTRIC CORPORATION Headquarters 2 9 32 Nakacho Musashino shi Tokyo 180 8750 JAPAN Branch Sales Offices Nagoya Osaka Hiroshima Fukuoka Sendai Ichihara Toyota Kanazawa and Kitakyusyu YOKOGAWA CORPORATION OF AMERICA 2 Dart Road Newnan Georgia 30265 1094 U S A Phone 1 800 888 6400 Fax 1 770 254 0928 YOKOGAWA EUROPE B V Euroweg 2 3825 HD Amersfoort THE NETHERLANDS Phone 31 88 4641000 Fax 31 88 4641111 Branch Sales Offices Wien Austria Zaventem Belgium Ratingen Germany Madrid Spain Runcorn United Kingdom Milano Italy Velizy Villacoublay France Budapest Hungary Stockholm Sweden Sola Norway Warszawa Poland Vila Nova de Gaia Portugal Bucharest Romania Dublin Ireland YOKOGAWA AMERICA DO SUL LTDA Praca Acapulco 31 Santo Amaro Sao Paulo SP BRAZIL Phone 55 11 5681 2400 Fax 55 11 5681 4434 YOKOGAWA ENGINEERING ASIA PTE LTD 5 Bedok South Road 469270 SINGAPORE Phone 65 6241 9933 Fax 65 6241 2606 YOKOGAWA ELECTRIC KOREA CO LTD 14 1 Yangpyongdong 4Ga Youngdeungpo Gu Seoul 150 866 KOREA Phone 82 2 2628 6000 Fax 82 2 2628 6400 YOKOGAWA AUSTRALIA PTY LTD Tower A 112 118 Talavera Road Macquarie Park N S W 2113 AUSTRALIA Phone 61 2 8870 1100 Fax 61 2 8870 1111 YOKOGAWA INDIA LTD Plot No 96 Electronic City Complex Hosur Road Bangalore 560100 INDIA Phone 9
17. 8 1 PMD DA esse teas ade O S 8 1 8 2 Previewing the Print mage sccccsseseccsnnseccenenseecesnaeeeennaseecnneeeesennaeeseneass 8 3 8 3 Saving Print Data As a Comma separated Value File sssseeeeseeeeeeeees 8 4 9 Monitoring VO Values nnanannannee once eee ne sere nge rere nge rere ne see nenes ene e ne nenen nes enen nenen 9 1 9 1 Opening the Monitor Dialog BOX na nananan ann nanneeen oe e eneve non seen even one eres eee ne eter ereseneeee 9 1 10 Adjusting JUXTA Instruments nn nnnnannnn nisnin ase nenen emo s enen n teres e eee ne eres e ne nenen 10 1 10 1 Opening the Adjusting Dialog BOX sauna nnnve cenon eee eren nene nene res nene sere resee eee 10 1 10 2 Performing Fine Adjustment Of Input na nanan ana nance nse ren n ns sene nenes eee nenes ese rem n eee e ne 10 2 10 2 1 Adjusting the Zero Point of Input aaa aaa aaa ccc aa ana eee nene e even reze eee ee zena 10 2 10 2 2 Adjusting the Input Span nana aananaaan nana ns ere vese ses eee re sasise se nee nese se se eeesesese 10 2 10 3 Correcting TING OUUU aaa dat d AEE 10 3 10 4 Setting Wire Resistance Compensation unnaa ann anenne ana o sene never enen e enen e nn ene nenen 10 4 10 5 Using the Forced Output FUNCTION nana nanancn nana nene eren n sense eee nenes e eee reres nene sere nesese 10 5 11 Troubleshooting aa j u cteaeie seesaw cae meee eee eeseewecnces 11 1 12 ADDED raver cscs ete set RE 12 1 12 1 selling Ihe PassWord srian ERES 12 1 12 2 Changi
18. A aang Setup Bootstrap for visual Bas yj Setup Lst LST File 6 KE File and Folder Tasks x Make a new Folder a Publish this Folder to the Web ka Share this folder WIT Tus CAB StuffIt Compressed File Other Places 3 414 a P 7 EJ J77 EN My Documents ig Shared Documents s My Computer J My Network Places Details x WITTE File Folder Date Modified Monday December 27 2010 11 11 E In Windows Vista Windows 7 the User Account Control screen appears Click Allow When installation is complete VJ77 is added to the Programs submenu of the Start menu 2 2 Uninstalling VJ77 Step1 From the Start menu of Windows select Control Panel gt Programs and Fea tures 1 gt VJ77 and uninstall it In Windows Vista Windows 7 the User Account Control screen appears Click Allow 1 From the Start menu of Windows select Control Panel gt Uninstall a program if the control panel s display method is Control Panel Home In Windows XP Add or Remove Programs IM 77J01377 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt lt Chapter 2 Setup gt 2 3 2 3 Connecting JUXTA Instrument to Personal Computer This section describes how to connect a JUXTA instrument to a personal computer 2 3 1 Items Required for Connection To connect a JUXTA instrument to a personal computer the following are required 1 Personal computer with VJ77 installed 2 Communi
19. N respectively as in INP ZERO and INP SPAN For example to set an input range of 10 to 10 V DC e Incase 1 set 10 for INPUT L_RNG and 10 for INPUT H_RNG e Incase 2 set 10 for INP ZERO and 20 for INP SPAN A WARNING When you set the range of a JUXTA instrument confirm the respective parameter codes to determine whether they are L RNG and H_RNG or ZERO and SPAN to make sure that you set 0 and 100 values of the range or set the 0 value and span AN CAUTION For a numeral parameter the number of significant digits is 4 For example if you enter 12345 the data value will be written as 12340 and if you enter 0 12345 the data value will be written as 0 12340 IM 77J01377 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt lt Chapter 4 Setting Parameters gt 4 5 4 2 3 Selecting an Item from a List Box and Writing It to JUXTA As an example of procedures to select an item from a list box and write it to the JUXTA instrument the following shows how to change the communication protocol for a JUXTA VJH7 an isolator whose output 2 is a communication port from MODBUS ASCII to MODBUS RTU Step 1 Inthe SET dialog box click the SET COM tab The SET COM page contains the communication settings SGC0Gps EWEN fbh lhi Goo Step 2 Double click the data cell for parameter PROTOCOL F01 The text box at the bottom of the dialog box then becomes available MODBUS ASCII Step 3 Click the arrow but
20. Step5 The Data Upload from JUXTA dialog box appears LEE Uploaded from JUSTA Step6 Select Check Content and click OK The Content List dialog box appears showing all the parameter values of the JUXTA instrument Content List MODELWIH 3 001 V 50 0 NORMAL NORMAL 0040 O LP4 0 00 GOOD a B DISPLAY2 3 001 V 050 0 96 NORMAL NORMAL GooD Co ee o D o SETWO A CAUTION The parameter values in the Content List dialog box cannot be changed IM 77J01J77 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt lt Chapter 6 Uploading and Downloading Data from to JUXTA gt 6 3 6 1 2 Opening a Parameter File Step 1 Start VJ77 In the Parameter Program Setting Menu dialog box select Param eter Setting then click OK If a password has been set enter the password in the Password Entry dialog box and click OK Step 2 The Parameter Setting Menu dialog box appears Select Read Parameter Data from a File and click OK C Set Cancel Upload Parameter Data from JUXTA Step 3 The Select File dialog box opens Select a file name from the list box and click Open To continue follow steps 5 to 6 in Section 6 1 1 Uploading Parameter Data from JUXTA Instrument Select File Look in SI Parameter EJ TIC 001 7pa File name TIC 001 7pa Files of type Parameter Filej pal Cancel See Aiso For how to save the parameter data to disk see Chapter 7
21. and select the model name from the Model Selection dialog box Select MXS B in this example Click OK Model Selection OE Old style j OK C Mis Cancel C MD i MST Wes 52 C VIS E We t Pees CWT C Whew To input program codes double click a Program cell and type a code In this example double click the Program cell in step G1 and type LDX1 In the same way input LDH1 in step G2 MAV in G3 STY1 in G4 and END in G5 To input a comment for each step inout the comment in the Comment cell A maximum of 25 characters can be entered for a comment Set the moving average time span to 100 seconds This data is to be specified as a percent value where 0 0 100 0 corresponds to 0 1000 seconds Double click the constant cell for H1 and enter 10 Now the program setting is complete Program Editor MODEL MxS B Model Selection STEP PROGRAM Comment Close Load input 1 Load CONST H1 i met Han Moving average Store the result in Y1 Delete Fav Undo Command Check Save to file Download to JUSTA Print IM 77J01J77 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt lt Chapter 5 Setting a Program gt 5 5 AN CAUTION In the Program Editor dialog box the step numbers of program cells and the constant numbers of constant cells differ depending on the JUXTA model selected Refer to the parameter lists given in the documentation for the respective JUXTA comput
22. ar click Password then Change MODEL VI7 NewFile File F Eommunication Settee Pas Parameter Program Setting Ma Change t Parameter Setting Program Setting Step 3 The Password Entry dialog box appears Type the old password 4 digit numeral and click OK Password Entry Enter password 4 digit Humeral E Password E z ance Step 4 The Set Change Password dialog box appears Type the new password 4 digit numeral in the New Password box and type the same numbers in the New Password Confirm box Set Change Password Ea Enter password 4 digit Humeral New Password E i Cancel New Password Continm jes Step5 Click OK Set Change Password E G Password has been set IM 77J01J77 01E 5th Edition Feb 28 2011 00 lt Int gt lt Toc gt lt Ind gt l Revision information Title Model VJ77 PC based Parameters Setting Tool Manual No IM 77J01J77 01E Dec 1999 1st Edition Newly published Jan 2004 2nd Edition Supports Windows 2000 and XP June 2004 3rd Edition Change of the company name July 2005 4th Edition Addition of new style product and automatic conversion function of free programs Feb 20011 5th Edition Supports Windows Vista Windows 7 and changes the media from floppy disk to CD Written by Yokogawa Electric Corporation Published by Yokogawa Electric Corporation 2 9 32 Nakacho Musashino shi Tokyo 180 8750 JAPAN IM 77J01J77 0
23. are 16 or less characters 7 1 Saving Parameter Data to Disk Step1 Follow the instructions in Section 6 1 Uploading Data to Your PC to upload parameter data Step 2 In the Data Uploaded from JUXTA dialog box or Data Read from a File dialog box select Save to File and click OK Data Uploaded from JUXTA Ok Check Content Cancel C Download to JUSTA Print Step3 The Save As dialog box opens In the File name box type the file name vvithin 16 characters and click Save The Information dialog box appears Save As Save ini J Parameter File name ric ooij Save az lype Parameter Filej pal Cancel IM 77J01J77 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt lt Chapter 7 Saving Data gt 1 2 Step 4 Inthe Information dialog box set the title subtitle author date instrument serial number and comments and click OK The file is saved to disk Indoim stion A maximum of 40 characters can be entered for each of the title subtitle author date and instrument serial number A maximum of 400 characters can be entered for a comment 7 2 Saving Program Data to Disk Step 1 Inthe Program Editor dialog box click Save to file The Save As dialog box opens Program Editor MODEL MXS B Model Selection STEP PROGRAM Comment Close G1 Load input 1 Load CONST H1 pra Moving average Store the resultin vi Pelete Rav Unda Comma
24. cation cable with 9 pin D sub female connectors at both ends comes with VJ77 E9786WK 3 VJ77 dedicated adapter comes with VJ77 E9789HA 4 JUXTA communication cable 3 pin connector type comes with VJ77 F9182ED Used when communicating with JUXTA F VV and M series 5 JUXTA communication cable 5 pin connector type comes with VJ77 F9182EE Used when communicating with JUXTA D series DSC2 6 Adapter for modular jack comes with VJ77 E9786WH Used when communicating with JUXTA VJ and M series 2 3 2 Howto Connect Step 1 Connect the dedicated cable IBM PC AT compatible cable with 9 pin D sub to the personal computer Then connect the VJ77 dedicated adapter to the other end of the dedicated cable Step 2 When communicating with JUXTA D series DSC2 connect the JUXTA commu nication cable with 5 pin connector F9182EE to the VJ77 dedicated adapter e When communicating with JUXTA F W and M series connect the JUXTA com munication cable with 3 pin connector F9182ED to the VJ77 dedicated adapter e When communicating with JUXTA VJ and M series connect the JUXTA commu nication cable with 5 pin connector to the VJ77 dedicated adapter then connect the modular jack adapter E9786WH to the connector of the JUXTA communi cation cable 6 Adapter for modular jack E9786WH 4 5 JUXTA communication cable F9182ED or F9182EE 3 Communication adapter E9789HA 2 Communication cable E9786Wk
25. e 1 1 1 1 1 Alis VIZA ee 1 1 1 1 2 UME TIONG e E 1 1 1 2 Conceptual VIEW OF VJ77 nana auun n ad add da dd n s d 1 2 1 3 Operating Environment and Wiring Specifications nunanannannnn ann n esse none ses emene ss 1 3 1 3 1 SVSICM R Qqulrem ni5 nzcucesiar an ve veri e 1 3 1 3 2 Communication Adapter aaaanaaaaaaaaaaan ana nanen enes e eres iken eee re nare pene ee eee ee eeeete 1 3 1 4 External View of Communication Adapter un nana nn nn ere none re sos sere nes eres e esse nenes 1 4 1 5 Precautions When Communicating with JUXTA annnannnnnn ann n neve nn sene n emen eee eenness 1 5 DP 2 1 2 1 installing VaT Fse hej EEE 2 1 2 2 LUKS KAN NI VI das ai Ge P A 2 2 2 3 Connecting JUXTA Instrument to Personal Computer s ceceeseeeees 2 3 2 3 1 Items Required for CONNECTION cccceeccceeeeeeceeseeeceeeseeaeeesenseeees 2 3 2 3 2 HOW AG GCOMMOGCT nervi aa etessaeebcowenavneas 2 3 2 4 Setting the COMMUNICATION PON una aa nana nn nenen ns nene ren sene rene see re mn e sene enes eee mem m enen 2 4 3 Basic Operation ad ens ud i sha na e u nnnm 3 1 3 1 SONING VJ FI aoe te n ad 3 1 3 2 PUNE Bere eeepc ss ete rc hante ew ete oe E ieee ew as ao 3 2 3 3 Dialog Box Elements and Functions na nunaaa nana nan eve na sene nene nenen rene sene ne sene nn nenen ene 3 3 3 4 BASIC ODE AU OT n pana soda e a E a Eaa 3 5 3 4 1 Operation USING a MOUSE aaa aaa nenen e eee eee nen ee eee eper ee eee eee 3 5 3 4 2 Ope
26. ew style MXS user program 59 steps and 59 fixed constants is converted to an old style MXS user program In this case conversion is not possible since the old style MXS can only have up to 40 steps and 44 fixed constants therefore the number of user program steps exceeds the limit Old style models MXS MXD MXT VJXS XJJMnnn New style models MXS B MXD B MXT B VIXS S2 VJX7 FXnn WXTn WXnn 6 Converting the start address of user programs and fixed constants CONST Target model to which the user Program start address CONST start address program is converted after conversion after conversion FXnn WXn WXTn MXS MXD MXT VJXS B20 C20 XJJMnnn VJX7 MXS B MXD B MXT B G01 HO1 VJXS S2 6 Converting operation code operation code LDC before conversion and operation code LDH If the new style target model to which the program is converted is either the VJX7 MXS B MXD B MXT B or VUXS S2 the operation code LDC is converted to LDH If the source model whose program is converted is new style VJX7 and the target model is either the FXnn WXTn or WXnn or either the old style MXS MXD MXT ViXS or XJJMnnn the operation code LDH is converted to LDC IM 77J01J77 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt lt Chapter 6 Uploading and Downloading Data from to JUXTA gt 6 1 6 6 1 6 1 1 Uploading and Downloading Data from to JUXTA This chapter describes how to upload down
27. gainst damage and ensure its safe use make sure that all of the instructions and precautions relating to safety contained in this document are strictly adhered to Yokogawa does not guaran tee safety if the product is not handled according to these instructions The following safety symbols are used in this manual 6 Symbols used on the product and in this manual user s manual to avoid the risk of injury or death of personnel or damage to the instrument This symbol on the product indicates that the operator must refer to an explanation in the The manual describes how the operator should exercise special care to avoid electrical CAUTION shock or other dangers that may result in injury or the loss of life Protective ground terminal This symbol indicates that the terminal must be connected to ground prior to operating the equipment Function ground terminal This symbol indicates that the terminal must be connected to ground prior to operating the equipment IM 77J01377 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt lt Rev gt lt Introduction gt Vil E Exemption from Responsibility 1 2 3 4 5 s NS Yokogavva does not make any vvarranties regarding the product except those men tioned in the WARRANTY that is provided separately Yokogawa assumes no liability to any party for any loss or damage direct or indirect caused by the use or any unpredictab
28. gram aaj b ki IM 77J01377 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt lt Chapter 8 Printing Data gt 8 3 8 2 Previewing the Print Image This section describes how to view the print image Step 1 Inthe Print dialog box click Print Preview to open the Print Preview dialog box If the data spreads over more than one page you can view other pages by clicking the arrow buttons next to the Page Setting box You can also change the display magnification by selecting the zoom factor from the Set Magnification list To return to the Print dialog box click Close IM 77J01J77 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt lt Chapter 8 Printing Data gt 8 4 8 3 Saving Print Data As a Comma separated Value File You can save the print data in a comma separated value CSV file e Filename extension of CSV files csv File names are 16 or less characters Step 1 Inthe Print dialog box click CSV file output The Save As dialog box appears Step 2 Inthe File name box type the file name within 16 characters and click Save Dave As Save ihi J Parameter File name TIC 001 Save s lype csv File ce Cancel IM 77J01J77 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt lt Chapter 9 Monitoring I O Values gt 9 1 9 Monitoring I O Values This chapter describes how to monitor input output values of a JUXTA instrument and the self diagnosis result Yo
29. he same procedure as that used for output correc tion To do so double click the OUT 0 or OUT 100 data cell and click WRITE IM 77J01J77 01E 5th Edition Feb 28 2011 00 SS SAN x Page S lt Toc gt lt Ind gt lt Chapter 11 Troubleshooting gt 11 1 11 Troubleshooting This chapter explains troubleshoot problems that may occur when running VJ77 6 Symptom Abnormal display Possible Cause There is a problem with the operating conditions of your computer Remedy Check whether your system meets the following requirements e Adisplay unit having a resolution of 800 x 600 pixels capable of displaying 256 colors or superior is required e Use of small fonts is recommended 6 Symptom The Communication error Check the connection message appears Possible Cause The communication cable is disconnected or power is not being sup Remedy plied to the JUXTA instrument Check the connection of the communication cable and the power to the JUXTA instrument 6 Symptom The Communication error Check the connection and try again message appears Possible Cause The communication cable was accidentally disconnected during com Remedy munication with the DSC or somebody reconnected the cable during Communication Check the cable connection and attempt communication again 6 Symptom The Parameter address error Communication will be termi nated message appears Possible Cause
30. ies On receiving the product visually inspect it for any damage E Checking Model and Suffix Codes Make sure that the model and suffix codes of the delivered product are as specified in your order ee PC based parameters setting tool For use with IBM PC AT compatible personal computers English version E Checking the Package Contents Make sure that the delivered package contains all of the following items VJ77 PC based Parameters Setting Tool CD aaa u uauuauaaaaaa aa anannn nanen enen nese 1 disk Communication adapter aaa aaaana aaa anen aaa see e eee e eren ane e rene ee eee ee ee teve ee even eee 1 unit Communication cable vvith 9 pin D sub female connectors at both ends 1 cable JUXTA communication cable 3 pin connector type auuuaauaaaaa aaa na nanen nane 1 cable JUXTA communication cable 5 pin connector type auuuaau u aaaa nan nanen ane 1 cable Adapter for modular ac Ks gemanoz san 1 unit User s manual this manual IM 77J01J77 01E ccceceessseeeeeeeeeees 1 copy IM 77J01377 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt lt Rev gt lt Introduction gt IV Documentation Conventions E Documentation Conventions The following conventions are used throughout this manual ltem The names of named dialog boxes windows and views are written in title cap and refer to the exact titles The names of unnamed windows dialog boxes and views are written in all lowercase letters
31. ing units FUN VVARNING DO NOT change a program for a computing unit of the JUXTA F series and JUXTA VV series other than programmable computing units In case the unit is operated on the com puting function with program changed after factory ship the operation will not be guaran teed IM 77J01J77 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt lt Chapter 5 Setting a Program gt 5 6 5 2 2 Functions to Facilitate Program Coding E To insert a step Click the cell immediately below the position where you want to insert a step then click Insert Row or press the F3 key Insert Row E To delete a step Click the cell of the step you want to delete then click Delete Row or press the key Delete Row TIP If the program contains a jump GO or a conditional jump GIF and a step is inserted or deleted before a destination to be jumped VJ77 automatically changes the destination step number specified with the GO or GIF code For example when GO6 meaning go to step G6 is set in step G2 deleting step G3 automatically changes the code in step G2 to GOS Or if step G6 the destination step is deleted GO6 in step G2 is automatically changed to simple GO namely the destination step number is cleared STEP PROGRAM comment STEF PROGRAM comment IM 77J01J77 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt lt Chapter 5 Setting a Program gt 5 E To check the syntax of the pr
32. int to Programs VJ77 then VJ77 Step 2 VJ77 starts up and the Parameter Program Setting Menu dialog box appears Parameter Program Setting 7 T T TT id r 7 m ak ek stem ci ll LLI IL RR RR RERE ERE R RE REI RERE R RE RES RERE RERE EESITT Program Setting DELJA Mem ile Fig CocmivcstoeSeteae P Hai Foiamebe Program Setting Hitnu IM 77J01J77 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt lt Chapter 3 Basic Operation gt 3 2 3 2 Quitting VJ77 You can quit VJ77 when any one of the following dialog boxes is displayed e Parameter Program Setting Menu dialog box e Parameter Setting Menu dialog box e Program Setting Menu dialog box e Menu dialog box e Data Uploaded from JUXTA dialog box e Data Read from a File dialog box Step1 From the menu bar point to File then Exit MODEL J NewFile File F Lenmunicstion Setings S Password Help rogram Setting Menu Program Setting Step 2 The Exit dialog box appears Click Yes to exit Q Is tO to quit the system Vler IM 77J01J77 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt lt Chapter 3 Basic Operation gt 3 3 3 3 Dialog Box Elements and Functions This section identifies the element and their functions of a window and dialog box of VJ77 with reference to the SET dialog box 2 Menu bar 1 2 3 4 5 6 7 1 Title bar 5 Parameter table
33. ired value In the SET dialog box after typing a numeral in the text box press the TAB key so as to select the WRITE button and then press the ENTER key The data is then written to the JUXTA instrument E Command buttons WRITE Close Cancel etc 1 Select a command button using the ARROW keys or TAB key 2 Press ENTER to execute the corresponding command IM 77J01J77 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt lt Chapter 3 Basic Operation gt 3 E Function keys For data entry in the Program Editor dialog box the following functions are assigned to the function keys While functions are assigned to Fn keys the assignment is displayed in the status bar at the bottom of the dialog box F2 Edits the active cell Select the desired program comment or constant cell namely a cell in the PROGRAM Comment or CONST column and press the F2 key The cell then allows a value to be entered F3 Inserts a row Pressing the F3 key when a program cell or comment cell is selected inserts a row above the selected cell F4 Delete a row Pressing the F4 key when a cell in a program cell or comment cell is selected deletes the row of the selected cell IM 77J01J77 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt Q9 lt Chapter 3 Basic Operation gt 3 3 5 Display Sequence Parameter Program Setting Menu Parameter setting slo A gt Kijua plomssed PN A
34. le defect of the product Be sure to use the spare parts approved by Yokogawa when replacing parts or consumables Modification of the product is strictly prohibited This software may be used with one specified computer only You must purchase another copy of the software for use on each additional computer Copying the software for purposes other than backup is strictly prohibited Store the compact disk original media containing this software in a secure place Reverse engineering such as the disassembly or decompilation of software is strictly prohibited No portion of the software supplied by Yokogawa may be transferred exchanged leased or sublet for use by any third party without the prior permission of Yokogawa IM 77J01J77 01E 5th Edition Feb 28 2011 00 SS 111 Page lt Toc gt lt Ind gt lt Rev gt Model VJ77 lt Introduction gt PC based Parameters Setting Tool IM 77J01J77 01E 5th Edition CONTENTS DEO CRUG TO oon aa sea ua s na s dul esse Kan A E A A E EE i Visual Inspection and Cross check of Accessories na nana nana ann nanen seen nse nn seen eee esesi lil DOCUMENTATION CONVENTIONS ccccceceeeeeseeeeeseeeenseeeeneesonseeeensesenseeeeanesoeseeneenesons iv NOUCG et oe crease aa OEE vi 1 VJ77 PC based Parameters Setting Tool na auunnana nanen anesore nonen sere nese nes ese 1 1 1 1 An Overview of VJ77 and lts FUNCTIONS nana nana nanen na nenen ose ren o seen nese nese sere nese nes
35. load parameter or program data Uploading Data to Your PC This section describes how to upload parameter or program data inside a JUXTA instru ment or open a parameter file Uploading Parameter Data from JUXTA Instrument Step 1 Start VJ77 Inthe Parameter Program Setting Menu dialog box select Param eter Setting and click OK Step 2 Ifa password is set for VJ77 the Password Entry dialog box appears Enter the password 4 digit numeral in the entry box and click OK This dialog box does not appear if no password is set Password Entry Enter password 4 digit Numeral OK Cancel Pagsword TIP A password can be set for security to prevent parameter and program settings for JUXTA instruments from being changed by an unauthorized person If a wrong password is entered data can be read from the JUXTA instrument but cannot be written to it See Also For how to set a password see Appendix Step3 The Parameter Setting Menu dialog box appears Select Upload Parameter Data from JUXTA and click OK Parameter Setting Menu 0K kK Cancel C Read Parameter Data from a File IM 77J01J77 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt lt Chapter 6 Uploading and Downloading Data from to JUXTA gt 6 2 Step 4 The Starts communication Press OK button if ready message appears Click OK to upload data from the JUXTA instrument Upload Parameter Data from JUXTA i ok EE
36. mended use small font RS 232C communication port At least 1 channel select from COM1 to COM16 IBMPC AT compatible model 9 pin D sub connector CD ROM drive 1 required for installation Printer Required for printing support for letter or A4 size 1 3 2 Communication Adapter Power supply Supplied from RS 232C port s DTR RTS DCD DSR and CTS However power supply may be unavailable depending on the RS 232C port s load characteristic In such a case use AC adapter additionally Specifications of external power source Should comply with EIAJ RC 5320A Input ratings 8 V DC 150 mA Connection to personal computer Straight cable with 9 pin D Sub connectors female at both ends is required for connecting via the RS 232C port Insulation resistance 100 MQ or more 500 V DC to connect to an RS 232C port and JUXTA instrument Dielectric strength 500 V AC for 1 minute to connect to an RS 232C port and JUXTA instrument Ambient temperature 0 to 50 C Ambient humidity 5 to 90 RH no condensation Transport and storage conditions 40 to 70 C 5 to 95 RH no condensation Dustproof and waterproof construction None IM 77J01J77 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt lt Chapter 1 VJ77 PC based Parameters Setting Tool gt 1 4 1 4 External View of Communication Adapter Unit mm JUXTA communication cable Dedicated cable Figure 1 4 1 External View of the Communication Adapte
37. mplete the adjustment 10 2 2 Adjusting the Input Span Apply the 100 level of the input to the JUXTA instrument If the signal level after A D conversion in the JUXTA instrument the value displayed in the P03 SPAN ADJ1 data cell and the actual input signal level do not match you must correct the input span The proce dure is the same as above IM 77J01J77 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt lt Chapter 10 Adjusting JUXTA Instruments gt 10 3 Ay CAUTION For some models HINC and HDEC are not included in the list The unit of signal differs depending on the model 10 3 Correcting the Output This section describes how to perform corrections of outputs The following shows an example when doing so for a JUXTA VJH7 isolator For wiring with a calibrator or other apparatuses see the user s manuals for respective JUXTA instruments Step 1 Double click the P12 OUT1 0 data cell and click WRITE The 0 level is then Step 2 forcedly set to the output regardless of the input level Calculate the percent value of the deviation from zero in the reading of the calibrator If there is a positive deviation correct it by setting a negative percent value to offset the deviation For example provided the output signal range of the JUXTA instrument is 4 20 mA DC and the reading of the calibrator when forcibly outputting the 0 value is 3 96 mA DC the error can be calculated as follows and set
38. nd Check Save to file Download to JUSTA Print Step 2 Inthe File name box of the Save As dialog box type the file name within 16 characters and click Save The Information dialog box appears In the same way as in Section 7 1 set the file information and click OK The file is saved to disk IM 77J01J77 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt lt Chapter 8 Printing Data gt 8 1 8 8 1 Printing Data This chapter describes how to print the parameter or program data Printing Data Step 1 To print parameters in the Data Uploaded from JUXTA dialog box or Data Read from a File dialog box select Print and click OK To print a program click Print in the Program Editor dialog box 6 Printing parameters Data Read from a File Cancel C Check Content C Save to file C Download to JUSTA 6 Printing a program Program Editor MODEL MXS B Model Selection STEP PROGRAM Comment Close Load input 1 Load CONST H1 Moving average Store the resultin vi Delete av leer Ear Urda Command Check Save to file Download to JUSTA Print IM 77J01J77 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt lt Chapter 8 Printing Data gt 8 2 Step 2 The Print dialog box appears You can select the ranges of items to be printed by selecting and clearing the check boxes Then click Print to start printing 6 Printing parameters 6 Printing a pro
39. ne ese 5 1 5 2 SELIG AP OCI QIN V dd n and uk nd an s dh E 5 3 5 2 1 Creating a New Program nana nanen nes p penne eee 5 3 5 2 2 Functions to Facilitate Program Coding cccccssseeseeeeeeeeeeeeeeeeeees 5 6 5 2 3 Converting Free User Program Automatically c cccccceeeeeeeeeees 5 8 6 Uploading and Downloading Data from to JUXTA ana unnanance nan nenes e venes esse 6 1 6 1 Uploading Data to Your PC aunnnaaan nana neneee no e enen eren ne eee teren nese teren es eee eren eee eee eer se 6 1 6 1 1 Uploading Parameter Data from JUXTA Instrument e 6 1 6 1 2 Opening a Parameter File nana ana anaaaanaan eee enen nen reve re enen even rene ese rrenen nes 6 3 6 1 3 Uploading Program Data from JUXTA Instrument aa aaa anon ann 6 4 6 1 4 Opening a Program File nana nana eee nn ene e epe e eee pe eee eee de nene rere ee 6 5 6 2 Downloading Data to JUXTA Instrument Jun nnn nani anen nan sere nan see re sone eren nenes eeenese 6 6 6 2 1 Downloading Parameter Data to JUXTA Instrument aaa uaauunaaaanannanennn 6 6 6 2 2 Downloading a Program to JUXTA Instrument aaa nanen ena eeeeni 6 7 7 AUN IDA LA n n s A v nd nje cen pas se kua E shaa e ue Ee uara seen 7 1 71 Saving Parameter Data to DISK nnnananannannnsen ns s eren os sene rene serre nes eren n esse r n se eren nenen 7 1 7 2 Saving Program Dala to DISK gujsss sa eko zane das du dd soda dd oi add 7 2 8 PANUNG DALA cise ces eeeca seen E E I E E 8 1
40. ng Dialog Box 6 Preparation Connect the JUXTA instrument to the personal computer then turn on the power to the JUXTA instrument Step 1 Start VJ77 Inthe Parameter Program Setting Menu dialog box select Param eter Setting then click OK Parameter Program Setting Menu Program Setting Step2 Ifa password is set for VJ77 the Password Entry dialog box appears Enter the password 4 digit numeral in the text box and click OK This dialog box does not appear if no password is set Password Entry Enter password 4 digit Numeral E Password Cancel TIP A password can be set for security to prevent parameter and program settings for JUXTA instruments from being changed by an unauthorized person If a wrong password is entered data can be read from the JUXTA instrument but cannot be written to it See Aiso For how to set a password see Appendix IM 77J01J77 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt lt Chapter 4 Setting Parameters gt 4 2 Step 3 The Parameter Setting Menu dialog box appears Select Set and click OK Parameter Setting Menu Step 4 The Starts communication Press OK button if ready message appears Click OK if ready If connected via the DSC or DSC2 port of the JUXTA D series carry out Step 5 Step 5 When connected via the DSC or DSC2 port of the JUXTA D series the SLOT No Setting dialog box appears Enter the slot number you wish to communicate with
41. ng the PaSSWwot siisii a 12 2 PLE VISION INformatiOn z adi Ga enis sree eh e gas de ua hd i IM 77J01J77 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt lt Chapter 1 VJ77 PC based Parameters Setting Tool gt 1 1 1 1 1 1 1 1 1 1 2 VJ77 PC based Parameters Setting Tool This chapter gives an overview of the VJ77 tool and describes its operating environment An Overview of VJ77 and Its Functions What is VJ77 The VJ77 PC based Parameters Setting Tool is a software package for setting various parameters and programs of microprocessor based JUXTA signal conditioners and com puting units from a personal computer This tool simplifies the configuration of high perfor mance functions of JUXTA instruments In addition it is also possible to adjust micropro cessor based JUXTA instruments using this tool Functions 6 Parameter setting Sets parameters that configure the functions of microprocessor based JUXTA instruments 6 Program setting Sets programs of microprocessor based JUXTA computing units 6 Download to upload from the JUXTA instrument Uploads parameters or program from a microprocessor based JUXTA instrument to a personal computer and downloads the parameters and program once loaded or a program you Created to a JUXTA instrument 6 Data saving to disk Saves parameters or program in a JUXTA instrument to the hard disk of a personal com puter etc 6 Data printing Prints parameters or
42. nit other than programmable computing units of the JUXTA VJ series JUXTA M series and WXT See Aiso For the how to create and modify a program in the Program Editor dialog box see Chapter 5 Setting a Program 6 1 4 Opening a Program File Step 1 Inthe Parameter Program Setting Menu dialog box select Program Setting then click OK If a password has been set enter the password in the Password Entry dialog box and click OK The Program Setting Menu dialog box appears Select Read Program Data from a File and click OK Program Setting Menu OF C New Cancel C Upload Program Data from JUST A Step 2 The Select File dialog box opens Select the file name from the list box and click Open The Program Editor dialog box appears allowing you to modify the up loaded program Step 3 Select File Look in SI Program PJEJUKTA OT For File names JUKTA 01 7pr Files of type Program File For Cancel See Also For how to save program data to disk see Chapter 7 Saving Data IM 77J01J77 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt lt Chapter 6 Uploading and Downloading Data from to JUXTA gt 6 6 6 2 Downloading Data to JUXTA Instrument This section describes the operation to download the parameter or program data from VJ77 to the JUXTA instrument You can copy parameter settings or a program to multiple JUXTA instruments AN CAUTION Befo
43. nosis 6 Chapter 10 Adjusting JUXTA Instruments Describes how to adjust JUXTA instruments input output how to correct the wiring resis tance and others 6 Chapter 11 Troubleshooting Describes how to solve problems when any trouble has occurred while using VJ77 Appendix Describes how to set a password security function Media No IM 77J01J77 01E FD 5th Edition Feb 2011 YK IM 77J01J77 01E 5th Edition Feb 28 2011 00 All Rights Reserved Copyright 1999 Yokogawa Electric Corporation lt Toc gt lt Ind gt lt Rev gt lt Introduction gt ll E intended Readers This manual is intended for people familiar with the functions of JUXTA signal conditioners and capable of working with Windows such as instrumentation and control engineers and personnel in charge of maintaining instruments and control equipment E Related Documents 6 Instruction manuals for individual JUXTA signal conditioners These manuals provide information about the procedure of installation and vviring of signal conditioners and parameter lists E Trademark All the brands or names of Yokogawa Electric s products used in this manual are either trademarks or registered trademarks of Yokogawa Electric Corporation Windows is a registered trademark of Microsoft Corporation USA IM 77J01J77 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt lt Rev gt lt Introduction gt IH Visual Inspection and Cross check of Accessor
44. nt parameter and program settings for JUXTA instruments from being changed by an unauthorized person If a wrong password is entered data can be read from the JUXTA instrument but cannot be written to it See Also For how to set a password see Appendix IM 77J01J77 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt lt Chapter 5 Setting a Program gt 5 2 Step 3 The Program Setting Menu dialog box appears Select New Upload Program Data from JUXTA or Read Program Data from a File depending on what you want to do then click OK Program Setting Menu Cancel Upload Program Data from JUKTA t Read Program Data from a File See Also For operations after selecting Upload Program Data from JUXTA or Read Program Data from a File see Chapter 6 Uploading and Downloading Data from to JUXTA The Program Editor dialog box appears You can now start setting a program Program Editor MODEL MXS B STEP PROGRAM Comment Close Insert Row Delete Aow Frati Command Check Save to file Download to JUSTA Print IM 77J01J77 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt lt Chapter 5 Setting a Program gt 5 3 5 2 Setting a Program This section describes the procedure to enter data via the Program Editor dialog box To set a program do one of the following e Create anew program e Upload program data from a JUXTA instrument and modify it e Read program data fr
45. ogram you created or modified Command Check Click Command Check Ay CAUTION e The Command Check function is disabled when setting up the program of any model whose name is not listed in the Model Selection dialog box e The Command Check buiton is only used to check the spelling of operation codes 6 A dialog box appears if no error is found Command Check ES G No error found 6 A dialog box appears when an error is found Command Check Error STEP PROGRAM Error Content Invalid operator IM 77J01J77 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt lt Chapter 5 Setting a Program gt 5 8 E To copy move program code comment or constant to another cell 6 To copy contents of a cell or characters Select a cell or characters and press the fer keys Then click the position to which you want to copy the contents of the selected cell or the selected characters and press the keys 6 To move contents of a cell or characters Select a cell or characters and press the fen keys Then click the position to which you want to move the contents of the selected cell or the selected characters and press the keys 5 2 3 Converting Free User Program Automatically This section explains how to convert old style MXS free user programs to those for the new style MXS Step 1 Upload free user program data from the JUXTA see Section 6 1 3 for details on the uploading procedure Ste
46. om a file and modify it Whichever method is chosen there are no major differences in operations in the Program Editor dialog box The following is an example of the procedure to create a new program 5 2 1 Creating a New Program The following is an example of the procedure to set a moving average computation of the last 100 seconds for a MXS free program AN CAUTION e When setting a program be sure to click Model Selection button to select a model see Step 2 in the following procedure Selecting a model name updates the con tents of the STEP and CONST columns accordingly e fthe model name of your target instrument is not included in the list of models click Close to return to the Program Setting Menu dialog box Then choose Upload Program Data from JUXTA and open the Program Editor dialog box again Step 1 Inthe Program Setting Menu dialog box select New then click OK The Program Editor dialog box appears Model selection button Constant cells MxS B E PROGRAM W E 2 a Comment Close Insert Aow Delete How Unda Command Check on ees alae e E a G10 311 Save to file G12 Download to JUXTA e Frint S nm s 4 Program cells Comment cells IM 77J01J77 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt lt Chapter 5 Setting a Program gt 5 4 Step 2 Step 3 Step 4 Step 5 Step 6 Click the Model Selection button
47. p 2 Inthe Program Editor dialog box click the Model Selection button Program Editor MODEL MxS I ion STEP PROGRAM Comment Close leer Ear Delete Feary Unde Command Check Save to file Download to JUSTA Print IM 77J01J77 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt lt Chapter 5 Setting a Program gt 5 9 Step 3 In the Model Selection dialog box select a new style MXS and click the OK button Check the command after conversion because some program codes are not available depending on the model Model Selection Program Editor HEET arty ETE Tam Step 4 Download the free user program to the JUXTA see Section 6 2 2 for details on the downloading procedure Step 5 Save the free user program to the disk as necessary see Section 7 2 for details on the saving procedure IM 77J01J77 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt lt Chapter 5 Setting a Program gt 5 10 E Automatic conversion of free programs Free programs can be converted from older style models to new style models or vice versa or between different models Converting a free program automatically causes the start address name start address number and operation code to be converted as well Auto matic conversion of free programs may not be possible however depending on the num ber of steps in the user program or on the number of fixed constants CONST Example Assume that a n
48. program cell or comment cell is selected inserts a row above the selected cell Delete Row button Clicking Delete Row when a program cell or comment cell is selected deletes the selected row Undo button Clicking Undo cancels the most recent operation you have performed Each click of this button restores the display to the state one operation before Command Check button After inputting program codes and constants clicking this button performs a syntax check of your entry IM 77J01J77 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt lt Chapter 3 Basic Operation gt 3 12 9 Save to File button Clicking Save to File saves the created edited program to disk 10 Download to JUXTA button Clicking Download to JUXTA downloads the created edited program to a JUXTA instrument 11 Print button Clicking Print prints the created edited program See Also For more information about the Program Editor dialog box see Chapter 5 Setting a Program IM 77J01J77 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt lt Chapter 4 Setting Parameters gt 4 1 4 Setting Parameters This chapter describes the operation to set parameters of JUXTA instruments using VJ77 Parameters are set in the SET dialog box See Also When you set parameters refer to the parameter lists given in the respective user s manu als of JUXTA signal conditioners and computing units 4 1 Displaying the Parameter Setti
49. program uploaded from a JUXTA instrument 6 Input output value monitor Views the I O values and the result of self diagnosis of a microprocessor controlled JUXTA instrument 6 Adjusting JUXTA instruments Adjusts inputs and outputs of a microprocessor controlled JUXTA instrument IM 77J01J77 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt lt Chapter 1 VJ77 PC based Parameters Setting Tool gt 1 2 1 2 Conceptual View of VJ77 Personal computer Reference to parameters Set parameters Set programs Adjust JUXTA Figure 1 2 1 Conceptual View of VJ77 PC based Parameters Setting Tool IM 77J01377 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt lt Chapter 1 VJ77 PC based Parameters Setting Tool gt 1 3 1 3 Operating Environment and Wiring Specifications 1 3 1 System Requirements OS Windows XP Home Edition Professional 32 bit version Windows Vista Business Service Pack 1 supported 32 bit ver sion Windows 7 Professional 32 bit 64 bit version CPU Pentium 300 MHz or higher recommended For Windows Vista Business or Windows 7 Professional Equivalent to 3 0 GHz or higher recommended Main memory Windows XP Home Edition Professional At least 128 MB recom mended Windows Vista Business Windows 7 Professional At least 2 GB recommended Hard disk space At least 6 MB for tool program and 2 MB for user files CRT 800 x 600 pixels or better 256 colors or more recom
50. r Mate Plug Unit mm 1 5 D DIA a Uli 85 ElAJ Figure 1 4 2 External View of the External Power Inlet on the Communication Adapter 5 5 DIA IM 77J01377 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt lt Chapter 1 VJ77 PC based Parameters Setting Tool gt 1 5 1 5 Precautions When Communicating with JUXTA Ay CAUTION When carrying out communication with a JUXTA instrument do not change the cable connection to another JUXTA instrument except when any of the following dialog boxes is displayed Also even if any of the following dialog boxes is displayed do not disconnect the cable while communication is in progress Otherwise a communication error will occur e Parameter Program Setting Menu dialog box e Parameter Setting Menu dialog box e Program Setting Menu dialog box e Data Uploaded from JUXTA dialog box e Data Read from a File dialog box e Program Editor dialog box IM 77J01J77 01E 5th Edition Feb 28 2011 00 SS SAN x Page S lt Toc gt lt Ind gt lt Chapter 2 Setup gt 2 1 2 Setup This chapter describes how to set up the hardware and software required to run VJ77 2 1 Installing VJ77 A CAUTION e Logon in Windows XP Log on using the user name of Administrators group The program does not start normally if the user name not belonging to the Administrators group is used for loggong on In Windows Vista Windows 7 install the software as an administrator
51. ration USING Keyboard 1 nn nanaaanann aa anna need ene eee eee eee penne eee 3 6 3 5 DIS plav SEQUENCE sa on P ua e 3 8 3 6 Main Dialog Boxes and Their FUNCTIONS muna nauna nan nanen no ase nenen e sene nenes eee e nn esen nenes 3 9 3 6 1 DISPLAY Dialog BOX aaa naaaaaaaananaaannaaae eee nenen ee eee eee eee eee eee eee eee eee eee eee 3 9 3 6 2 SE T Dialog BOX di REA 3 9 3 6 3 ADJUST Dialog BOX ccccccscseceeeessseeeesaseeeeseeseeeesaseeessoesesensases 3 10 3 6 4 Program Editor Dialog BOX sswecantwrteanceaincsenadnniiacereiuedeaninnddameneenanenninnas 3 10 IM 77J01J77 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt lt Rev gt lt Introduction gt X 4 Setting Parameters nununnnnana nanen ase esse kene re SS ere SER S SE RERE E KE SE ESSE ESSE re SS e rene e r n s eme 4 1 4 1 Displaying the Parameter Setting Dialog BOX dunnananannnnnn nanes ee none eren nese ee menese 4 1 4 2 CUEING Parameter S s san ii uj dk n ah E ed nd neo 4 3 4 2 1 Entering a Setting Value and Writing It to JUXTA ccseeeeeeeeeeeeees 4 3 4 2 2 Notes on Setting Parameters cccccccccseseeeeceeeeeeeceesseeeeseneeeeseeees 4 4 4 2 3 Selecting an Item from a List Box and Writing It to JUXTA 4 5 5 SUNGA Progra sa ececccnenssesecectestececeanessestecncsnetacnauepestiecccsevecesenavassaimeseans 5 1 5 1 Opening Program Editor Dialog BOX ka nananannn nn naneee ona nenen eee sos e eee venes eee ee rem
52. re you download parameter data make sure that the model name of the JUXTA instrument selected in MODEL box matches with that of the product s nameplate For some models VJ77 cannot determine whether it is a standard product or a customized product and a communication error may result 6 2 1 Downloading Parameter Data to JUXTA Instrument Step 1 In the Data Upload from JUXTA or Data Read from a File dialog box select Download to JUXTA then click OK Data Read from a File OF C Check Content Cancel C Save to file Print Step 2 The Starts communication Press OK button if ready message appears Click OK to download data to the JUXTA instrument Step 3 The Now Communicating dialog box appears and shows the progress of down loading When the download is complete the Downloading to JUXTA com pleted message appears AN CAUTION VJ77 only downloads the data shown in the SET dialog box Data shown in the DISPLAY or ADJUST dialog box is not dovvnloaded IM 77J01377 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt lt Chapter 6 Uploading and Downloading Data from to JUXTA gt 6 7 6 2 2 Downloading a Program to JUXTA Instrument Step1 Inthe Program Editor dialog box click Download to JUXTA Program Editor MODEL MXS B Model Selection STEP PROGRAM Comment Close Load input 1 Load CONST H1 Moving average Store the resultin 41 Delete Eon Reer Biar Urda Command Check
53. s representing the displays may differ from the actual displays in regard to the position and or display characters uppercase or lowercase for example but not to an extent that impairs a correct understanding of the functions and the proper setting operation IM 77J01J77 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt lt Rev gt Notice lt Introduction gt vi E Regarding This User s Manual 1 2 3 C a This manual should be passed on to the end user Keep this manual in a safe place Read this manual carefully to gain a thorough understanding of how to operate this product before you start using it This manual is intended to describe the functions of this product Yokogawa Electric Corporation hereinafter simply referred to as Yokogawa does not guarantee that these functions are suited to the particular purpose of the user Under absolutely no circumstances may the contents of this manual in part or in whole be transcribed or copied without permission The contents of this manual are subject to change without prior notice Every effort has been made to ensure accuracy in the preparation of this manual Should any errors or omissions come to your attention however please contact your nearest Yokogawa representative or our sales office E Regarding Protection Safety and Prohibition Against Unauthorized Modification 1 2 In order to protect the product and the system controlled by it a
54. t Chapter 3 Basic Operation gt 3 6 3 To enter data via the Program Editor dialog box double click the cell you wish to enter data and directly enter data in the cell STEP PROGRAM Comment S1 JLo 3 4 2 Operation Using Keyboard E Menu bar operation 1 Press the F10 or ALT key on the keyboard File in the menu bar is displayed as a button indicating that it is selected Move to the menu item you wish to execute using the RIGHT ARROW and LEFT ARROW keys then press the ENTER UP ARROW or DOWN ARROW key The menu of the selected item is then displayed Pressing the ALT key F key opens the pull down menu of File 2 Inthe pull down menu move to the command you wish to execute using the UP ARROW and DOWN ARROW keys then press ENTER 3 To cancel the operation press the ESC key E Selecting an item 1 In a dialog box each press of the TAB key switches the selected command in turn To select a cell in a table use the UP ARROW DOWN ARROW RIGHT ARROW and LEFT ARROW keys The selected cell is displayed with thicker borders E Data entry operation 1 To enter a value in a cell in the SET dialog box press the CTRL ENTER keys The cell is then displayed with thicker borders thus allowing an entry to be made To enter a value in a selected cell in the Program Editor dialog box press the CTRL ENTER keys or F2 key The cell is then displayed with thicker borders thus allowing an entry to be made Y Type the des
55. t of Input This section describes how to perform fine adjustments of inputs The following shows an example when doing so for a JUXTA VJH7 isolator For wiring with a calibrator or other apparatuses see the user s manuals for respective JUXTA instruments 10 2 1 Adjusting the Zero Point of Input Step 1 Apply the 0 level of the input to the JUXTA instrument If the signal level after A D conversion in the JUXTA instrument the value displayed in the P02 ZERO ADJ1 data cell and the value actually input do not match perform the following steps to offset the zero point shift Step 2 Double click the P02 ZERO ADJ1 data cell The text box at the bottom of the ADJUST dialog box becomes available Step 3 Click the down arrow next to the text box to open a list which contains the follow ing ADJUST ADJUST TEST i oid AS O00 0 00 RESET GOOO 01 0013 v RST WRITE OOO WAST OOS WY ING 10013 Wo HUNG 01 001d w HDEC V INC Adds the specified voltage after A D conversion V DEC Subtracting specified voltage after A D conversion V RST Resets the value that has been adjusted by INC or DEC to 0 HINC or HDEC Adjusts the value by about 10 times that specified by the INC or DEC command Step 4 Since the value shown in the P02 ZERO ADJ1 cell is larger than the actual input level in the example above select V DEC and click WRITE Repeat this procedure to co
56. ted E Field wiring for thermocouple converter E Field wiring for mV converter Thermocouple converter Short circuit here Voltage generator Connect both wires to the same output terminal IM 77J01377 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt lt Chapter 10 Adjusting JUXTA Instruments gt 10 5 E Field wiring for RTD converter RTD converter Short circuit all wires at the terminals of the RTD element 10 5 Using the Forced Output Function Using the forced output function allows you to perform function tests of the equipment connected to the JUXTA instrument s output terminals Step 1 In the ADJUST dialog box click the TEST tab Step 2 Double click the Q02 OUT1 TEST data cell In the text box enter the percent value of the level you want to output To output the 100 value forcedly for example type 100 and click WRITE 100 WRITE The 100 value is then output During forced output the selected cell is yellow ADJUST TEST I I 3 UT2 TEST ELF CHE OOD PARAMETER DATA Close aie Oy Oa ho Cancel Forced Output 100 0 WRITE Step 3 To cancel forced output click Cancel Forced Output or double click another parameter TIP The ADJUST dialog box for some models of JUXTA does not have the TEST page on which you can forcibly set an output level Even with such models however it is possible to output 0 and 100 levels forcedly by t
57. tion Feb 28 2011 00 lt Toc gt lt Ind gt lt Chapter 3 Basic Operation gt 3 10 3 6 3 ADJUST Dialog Box This dialog box is used to adjust the I O of the JUXTA instrument 000014 RAT See Also For more information about the ADJUST dialog box see Chapter 10 Adjusting JUXTA Instruments 3 6 4 Program Editor Dialog Box This dialog box is used to create edit programs for JUXTA computing units 1 Model selection button 4 Constant cells ll S a Tla gji 21 18 2 Program cells 3 Comment cells IM 77J01377 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt 1 2 3 4 5 6 7 8 sChapter 3 Basic Operation gt 3 11 MODEL selection button Clicking Model Selection selects the model name of a JUXTA computing unit OF Old Style I MS C MSD MXT C vs 52 CO VIKS C VIKT Cancel Ft I MT ET Met Program cells Cells to input program codes Comment cells Cells to input a comment for each line of the program A maximum of 25 characters can be entered for a comment Constant cells Cells to input constants used in the program When Upload Program Data from JUXTA is executed and the Program Editor dialog box is displayed these cells show the program and constants uploaded from the JUXTA instrument Insert Row button Clicking Insert Row when a
58. ton V next to the text box select MODBUS RTU from the list which opens and then click WRITE The change you made is written to the JUXTA instrument MODBUS ASCII ti WRITE MODBUS ASCII MODELIS BTU FO2 ADDRESS F03 BAUD RATE 9600bps EWEN abit 1hit GOOD MODBUS ATU ri HITE IM 77J01J77 01E 5th Edition Feb 28 2011 00 SS SAN x Page S lt Toc gt lt Ind gt lt Chapter 5 Setting a Program gt 5 1 5 Setting a Program This chapter describes the procedure to set a program for a JUXTA instrument via the Program Editor dialog box See Also When setting programs refer to the parameter lists given in the documentation for the respective JUXTA computing units For details about creating a program see the Technical Information documents for the respective programmable computing units document No TI 231 01E or TI 1501 01E 5 1 Opening Program Editor Dialog Box Step 1 Start VJ77 Inthe Parameter Program Setting Menu dialog box select Program Setting then click OK Parameter Program Setting Menu Parameter Setting Step 2 Only if a password is set for VJ77 does the Password Entry dialog box appear In the Enter password 4 digit Numeral box type the 4 digit password and click OK This dialog box does not appear if no password is set Password Entry Enter password 4 digit Mumeral OK Password SY Cancel TIP A password can be set for security to preve
59. u can monitor this information via the DISPLAY dialog box 9 1 Opening the Monitor Dialog Box 6 Preparation Connect the JUXTA instrument to the personal computer then turn on the power to the instrument Step 1 Start VJ77 Inthe Parameter Program Setting Menu dialog box select Param eter Setting and click OK If a password is set enter the password in the Pass word Entry dialog box and click OK Step 2 The Parameter Setting Menu dialog box appears Select Set and click OK Parameter Setting Menu Ok Kk Cancel C Upload Parameter Data from JUHTA C Read Parameter Data from a File Step3 The Starts communication Press OK button if ready message appears Click OK Step 4 The Menu dialog box appears Select DISPLAY and click OK MODELMJHF UK _ Cancel C ADJUST Step5 The DISPLAY dialog box appears For some models of JUXTA this dialog box has the DISPLAY1 and DISPLAY2 pages IM 77J01J77 01E 5th Edition Feb 28 2011 00 lt Toc gt lt Ind gt lt Chapter 9 Monitoring I O Values gt 9 2 6 DISPLAY1 page of DISPLAY dialog box TIP The DISPLAY1 page or the DISPLAY dialog box without a tabbed page shows the condi tions at the time of communication However the DISPLAY2 page updates its display contents in approximately 5 second intervals periodic upload for updating To update the display data on the DISPLAY1 page or in the DISPLAY dialog box without a tabbed page double
Download Pdf Manuals
Related Search
Related Contents
User`s Guide Model Beta 98/S User Guide - nuance Veranstaltungstechnik GmbH SC-300 Manual HD5410 HD5410 - ReparierMich.de 1 - yodobashi.com WORKCENTERS™ MANUAL INSTALLATION ROLAND TB 303 User Manual - DIGITAL imaging Principes d`optimisation Chauffages jusqu`à 70 kW Installations sans Copyright © All rights reserved.