1. Eme efor non EU countries is available Stay _ Arming mode Night WAN C This arming mode is used when you want to arm the system with the person staying inside of the premise The interior zones are left disarmed if anyone opens door won t be the entry delay and the alarm will sound This arming mode is effective when the door and windows are secured by the opening sensors or there are installed glass break detectors Arming Fria e for EU countries Night Gas efor non EU countries is available Night SECOL ink Intruder alarm system Partial arming ie This is universal way of arming which enables to arm selected partition in desired arming mode A Example Only the first partition is armed This kind of arming is available in 2 storied house when at night EN the ground floor isn t used all sensors of this partition are armed When somebody opens doors will be an entry delay KM24 KM24A keypad Short user manual 10 26 25 C 01 44 Arming pgs I istFloor Away 2 2ndFloor System joel UO Press ENT toarm will be Press toselect mode armed Press 1 4 to select part 1st Floor 2nd Floor Press key Press key to select arming Using keys check all System will be armed mode For partial arming press partitions which have to be armed amp keys Press key to confirm the decision Arming and di
2. user will receive a call when an alarm is triggered The main difference between Call on alarm and Mandatory call is that user will receive a call even if the user before him in the list acknowledge the call by pressing 0 or by entering PIN SMS on trouble user will receive the SMS when a trouble appears on system example battery low Testing SMS user will receive the test SMS Settings CAAC Cell phones GSM o Cj el ws es x Remote control with any cell phone Smart control with Android OS phones The GSV2x is working in the system in the same way as the extra keypad and emulates basic features of the keypad In order to control the security system user must call to GSV2x When a connection is established via the GSM network user must enter a valid security system PIN and press In order to disarm the system user must enter 0 in order to arm the system user must enter 1 Command 007 is used to start the microphone Fulllistof commands can be found in GSV2x module user manual Smart phone owners have big advantage against the classic phone owners because they can use a Secolink application and control the system without any commands to remember Simplified wizard allows to set up necessary settings very easily When this action is done user will control the system by pressing corresponding buttons only Application commands User can arm selected partitions in selected arming
3. Off key LED is always Off Prompt key LED blinks when the system is ready to be armed Armed keyLEDis steady On when the system is armed Armed and Prompt key LED is steady On when the system is armed and blinks when the system is ready to be armed Settings Keypad Settings Light amp Indication Enter PIN G key LED 9 00 Note if the system is partially armed the prompt has a priority against status armed partition eet key LED 0 ORO Available backlight modes for key O Off key LED is allways Off eh ae Prompt key LED blinks when the system is armed and is ready to be disarmed Settings m OQ Keypad Settings Light amp Indication 9 Enter PIN OQO e key I LED OG Mees key LED Available backlight modes for key 22 Q Off keyLEDis allways Off aS Not Ready key LED blinks if there are violated zones w Zone Bypass Status key LED is ON when there are bypassed zones m AD Seti MD 000 Keypad Settings Light amp Indication Enter PIN m O MM B _ l key LEDJ 0G SECOL ink KM24 KM24A keypad Intruder alarm system Short user manual Set key LED 2 O Available backlight modes for key SOOO Off key LED is always Off S Pre Ala
4. The blinking duration is 30 seconds During this time is possible to make __ usual arming procedure N SECOLink KM24 KM24A keypad Intruder alarm system Short user manual Emergency keys In order to call for a help the premises must be secured by CMS press at once two specific keys and hold them pressed down at least 1 second When emergency alarm occurs siren starts to sound and alarm message will be shown on the keypad display e Fire alarm amp e Medical alarm Panicalarmm Ways of disarming Disarming can be done by two ways with special key or by entering PIN code When disarming is activated with the key user has possibility to disarm all or selected partitions For partial disarming it s necessary to unmark the partitions which will be disarmed unmark the partitions by pressing keys or select partitions by pressing keys and unmark mark by pressing or keys When disarming is activated by entering PIN code all partitions which are controlled by user will be disarmed Disarming by PIN code when entering the premise EErEE AN After opening the door which are protected the system begins to count the entry delay During this time it is A necessary to enter PIN code All partitions which are controlled by user will be disarmed EErEE Partial disarming Partial disarming is useful when part of partitions should be disarmed Thi
5. The last number should be pressed and held for 2 sec to bypass the zone for a long time permanently The zone will be marked by capital X When all zones are marked press the key The same actions can be performed by selecting the zones with the keys or and by marking unmarking with the key short press temporal zone bypass long permanent zone bypass Abort armin LQ 1 For selection aborting also arm procedure aborting the system SECOLink has the key If the exit delay is in process and you want to abort arming press the key and enter PIN code Arming system with troubles EU standards unexpect using of the system which has troubles When key is backlighted with green color the arming is impossible in the ways which were described earlier It is necessary immediately eliminate troubles also inform CMS and company which had installed the system The system detects troubles in own modules also it detects and other common troubles like 230V e 10 26 25 C 01 44 Sys Trouble AC Loss 0 0 0 0 ae disappearance in AC line disconnected phone line because of repair battery discharge In exceptional a casesis possible to bypass the troubles for a short time and arm system as usual ae It can be done this way Press the key once message about the trouble will be shown on the display Press the key again the key backlight starts to blink fast
6. When arming is activated with the key user has a possibility to arm all or selected partitions For partial arming it s necessary to mark the partitions which will be armed mark the partitions by pressing keys or select the partitions using keys and mark by pressing or keys and press the key for decision confirmation When arming is activated by entering PIN code all partitions which are controlled by user will be armed in Away mode Arming mode Away AN This arming mode is used when you want to protect a premise when nobody will be staying inside After m se arming all Zones will be protected After using the door willbe entry delay time for disarming Arming e for EU countries Away C HHHH efor non EU countries is available Away Rl En EEE wx Arming mode Vacation This arming mode is used when we are leaving the premise for a long period e g vacations After arming allzones will be protected entry delay is off alarm will sound upon opening door Arming Oa I PTET e for EU countries Vacations C efor non EU countries is available Vacations PIN code ins Arming mode Stay This arming mode is used to protect a house when we are staying at home inside and are waiting that somebody can come in Interior zones aren t protected After opening the door willbe entry delay Arming e for EU countries Stay
7. chime zone or zone marked by sign in the Events from zones list is violated or the any keypad key is pressed Settings Keypad Settings Light amp Indication Enter PIN LCD Backlight w 0 Settings Keypad Settings Light amp Indication Enter PIN e Keypad backlight Q Status LEDs Backlighted keys are used to show system status or prompts Status and prompts can be always visible or can be visible for a 40 seconds after the predefined condition was present for example when a zone marked by sign in the Events from zones list was violated This way allows to install keypad in bedroom when during the night time the additional light from the keypad status keys will not disturb the sleep If the status and prompts are not necessary they can be disabled Available settings Off Always status LEDs are always visible By zone status LEDs are visible when an entry exit delay is in progress an alarm is triggered a chime zone or zone marked by sign in the Events from zones list is violated or the any keypad key is pressed Settings Keypad Settings Light amp Indication Enter PIN Status LEDs m M Note These settings have a priority in relation to the certain key backlight settings described below key LED Available backlight modes for key
8. Available fixed PIN lengths 4 digits 5 digits 7 digits If PIN length is undefined variable user must press key after the last PIN digit is entered The PIN length can be changed via the menu Settings Keypad Settings Inaterface Settings Enter PIN 9 DMOO PIN Length m SECOLink KM24 KM24A keypad Intruder alarm system Short user manual LCD display brightness and contrast LCD display brightness and contrast can be modified to correspond to premise illumination conditions and user needs These settings can be modified via menu Settings 4 Keypad Settings Light amp Indication Enter PIN m GO 0O00 LCD brightness Settings Keypad Settings Light amp Indication Enter PIN m OOOO 0000 Contrast LCD display and keypad key backlight modes Backlight modes allows to install keypad in various place In place where it is not necessary to hold the keypad key backlighted the keypad can be set to backlight the LCD display only example hallway The keypad keys can be illuminated after the any key is pressed or zone next to PIR is violated Available keypad LCD display and keypad key backlight modes Always backlight is always ON By zone backlight will be turned ON when an entry exit delay is in progress an alarm is triggered a
9. keys or by selecting with keys and marking with key The chime zone will be marked by Press the key for chime melody changing Chime or Mand Setting Date and time Settings Date and Time enter date and time YYYY MM DD DD MM YYYY Date Format Two different date formats are available in the system Year Month Day YYYY MM DD or Day Month Year DD MM YYYY Date format can be changed via the Settings OOO Keypad Settings Interface Settings Enter PIN Date Format OG amp Show Date and Time If itis not necessary to see Date and Time on keypad LCD screen then the Date and Time can be hidden via the menu Settings Keypad Settings Interface Settings Enter PIN Show Date amp Time amp MG amp Prompt Change Time The keypad is automatically showing prompt to change date and time each time after system power up Ifit is notnecessary to see this prompt then this prompt can be disabled via the menu Settings Keypad Settings Interface Settings Enter PIN Prompt Change Time amp SECOLink KM24 KM24A keypad Intruder alarm system Short user manual Latin Cyrillic Greek Baltic Europ
10. mode Away Stay Night Vacation User can disarm all partitions User can control pre programmed outputs The output can be pre programmed to turn On Off the heating or ventilation or control other devices This button is used to receive system status from the security system All received messages from the security system are stored in event log Clear Alarm User can bypass unbypass selected zones Temporal and permanent zone bypass modes are available User can edit object settings edit object name phone numbers login PIN and other WWW link to manufacturer website Application settings Exit fo MAN System compliance and warranty The system is made in Lithuania A warranty term is 24 months The manufacturer company Kodinis Raktas declares that product SECOLink complies with essential EU directive and EU standard EN 50131 1 See manufacturer s web site www kodinis It www secolink eu for complete text of declaration 2011 Kodinis Raktas
11. performed the siren stops to sound the key backlight binking red goes off the system will be disarmed if it was armed before entering PIN code When all partitions which are controlled by User are disarmed it s not recommended to use PIN for alarm clearing because is possible casual arming 070 000 0 0 0200 o o Event log review All events which are concerned with protected premises and status of the system are stored in the Event Log The events are listed in chronological order the used can choose to review Alarm Events Trouble Z Events Control Events or All Events Event log review AYZ 0000 Event Log Alarm Events r amp Event Log Trouble Events Ome Use keys for navigation on the log SECOLink KM24 KM24A keypad Intruder alarm system Short user manual Sensor operation testing testing zones It is recommended to do sensor work test at least one time per month During a testit is necessary to make a violation of Zone it means to open door or windows which have magnetic contacts or to simulate movement near the motion sensor Glass break detector can be tested by hard clapping hands Testing Test Burglary zone test Cm1 Zones Zones 1 1 2 Hallway Testing zone 2 Hallway Testing zone 3 Kitchen is not violated 3 Kitchen is violated 4 Bedroom 4 Bedroom Zones which were violated
12. SECOLink KM24 KM24A keypad Intruder alarm system Short user manual SECOLINK KM24 KM24A are new concept keypads The large graphic display with help texts on it and a keys with backlight simplify understanding of alarm system User has possibility to customize main screen information to change contrast and backlight intensity of LCD and illumination of keypad keys By following blinking keys prompts user can easy operate the system without any commands to remember Arming disarming and bypassing of zones are so easy it can be done intuitively The main display view and and the main keypad functions are listed on the figure below Date field Temperature field Time field Cc Pe SECOLink Ie 10 26 im H 25 C 01 44 Partition status field READY TO ARM System status field 1st Floor 2nd Floor Sound settings Garage i System information a A AO Return to upper menu level alarm trouble review and clear z 3 2 CH Zones partitions Arming Disarming Zone bypass Navigation keys Emergency keys Entering selected menu item value entry selection confirmation Partition review also marking of the all partitions or selecting of other system elements Zone review also marking of the partitions or other system elements Ways of arming The system can be armed by two ways with special key or by entering PIN code
13. a help text is available for the Away arming mode Press key to read the help text Information about system Information about system central monitoring station installer power supply voltages can be found in information menu In order to enter this menu user must press key when keypad is showing main display view Choose the corresponding menu enter it by pressing amp key SECOLink KM24 KM24A keypad Intruder alarm system Short user manual Communication and messaging GSV2x module must be installed This menu provides the configuration for the phone numbers that the GSV2x module will use when sending a SMS or when calling to user Number phone number must be entered in international format The sign is added automatically Smart Phone this option must be enabled if the user has an Android OS application SECOLINK pre installed on his phone SMS on arming user will receive the SMS when system was armed User s name who armed the system will be mentioned in SMS text SMS on disarming user will receive the SMS when system was disarmed User s name who disarmed the system will be mentioned in SMS text SMS on alarm user will receive the SMS when an alarm is triggered Call on alarm user will receive a call when an alarm is triggered Incoming call must be acknowledged by pressing 0 or by entering PIN Mandatory call
14. are checking by pressing the key test finishes by pressing Permission to make changes of the system service mode entry For security reasons Installer will have permission to make changes of the system setting only after User approves it by entering his PIN Service Mode Enter User PIN Enter service PIN Cm Activated User PIN code changing The manufacturer provides the system with 4 digit number default PINs Each user has default PIN according his number in the system For example the default PIN for the first User will be 0001 for the second User 0002 and etc After installation itis strongly recommended to change default PIN Settings Users 9 Change PIN Enter the present PIN x New PIN ex Repeat Enw Changed Activated Users review After system installation is recommended to review how many Users can control the security system Settings Users Edit Users Gn LCD display will show User number for example U01 and mode Enabled or Disabled All Users who have mode Enabled can control system or it s partitions Chime mode Chime function is used to inform User with the sound or light signal LCD display backlight of keypad keys about opening of entry exit door or violation of other selected zone From which zone chime will be activated you can set by pressing the
15. ean Character Set An appropriate character set allows to enter partition module user or zone names by using national language characters Settings OOO Keypad Settings Interface Settings 9 Enter PIN m Character Set OG w Show status icons Keypad has an icon set to represent a different status in each partition Available icons partition is armed in the Stay mode partition is armed in the Night mode amp partition is armed in the Vacation mode partition is armed in the Away mode partition is disarmed zone is violated 1 Pre Alarm mode is turned On Icon based partition status showing is enabled by default If itis not necessary to see these icons on keypad LCD screen then the icons can be hidden via the menu Settings keypad Settings 9 Interface Settings Enter PIN c O Show Status Icons Temperature correction on keypad display KM24A If the keypad shows an incorrect environment temperature it is recommended to make temperature correction which can be done by entering value of temperature measured with domestic thermometers The correction can be made via the menu Settings Temperature Correction enter temperature value Show temperature If it is not necessary to see temperature the keypad LCD screen the
16. matically turned Off when the keypad is notin use for last 40 seconds The key will be used for a status indication Interface settings LCD backlight By zone see LCD display and keypad key backlight modes Keypad backlight By zone see LCD display and keypad key backlight modes Example Status LEDs status Always see Status LEDs key LED Armed see key LED key LED Off see key LED key LED Off see key LED key LED Off see key LED Events from zones no zones are marked see Events from zones Entry Exit sounds no partitions are marked see Entry exit sounds LCD brightness level 7 see LCD display brightness and contrast LCD contrast level 7 see LCD display brightness and contrast Help texts Keypad is equipped with a special key The key LED blinks if there is some additional information By pressing this key user can find information how to manage a system or problem 25 C 01 44 Arm i ng This arming mode is used time for disarming when you want to protect Awa a premise when nobody Press CLR to exit R EA DY TO A R M y will be staying inside After 1stFloor Press ENT to arm 2nd Floor Press A to select mode protected After using the Press 1 4 toselect part door will be entry delay arming all zones will be Press key key will start to blink It means that Use or for navigation Press to exit there is
17. rm status key LED is steady On when the partition is secured with Pre alarm mode On Settings Keypad Settings Light amp Indication Enter PIN OOWOOO id key LED MG Events from zones This menu is visible when in above mentioned LCD display or keypad interface settings the option By zone has been selected The key is used to mark unmark the zone Settings m OQO Keypad Settings Light amp Indication Enter PIN DOO Events from zones ENT M Entry exit sounds When the entry exit delay is in progress the remaining time is shown on keypad displays the sound signal is audible It is possible to turn ON this sound signal on certain keypad and to turn OFF on the other one In order to do it mark unmark the partitions by sign pressing the key Settings Keypad Settings Light amp Indication Enter PIN m MMMMMO Entry Exit sounds ENT M M Interface example A major benefit of the keypad is that it interface can be very easily customized An example describes the keypad interface setup when the keypad is installed in the bedroom The bright light source and the additional sounds excluding an alarm are not allowed in this room The keypad LCD brightness and contrast levels will be reduced LCD and keypad key backlight will be auto
18. s kind of arming is available in house with garage The house partitions are disarmed the garage partition remains armed Disarming 9 25 C 01 44 i i Partitions Disarming 1 Di ARMED Fullsystem 2 2nd Floor isarming 3 Garage 1stFloor 2 ndFloor Press ENT to disarm Garage Press 1 4 to select part Enter PIN Press key For partial disarming press Using keys unmark all Enter PIN keys partitions which have to be disarmed Press key to confirm the decision Alarm clearing gt 3 58 If an alarm has occured on the display appears message Alarm with an explanation what reason Alarmili causedit Key backlight starts to blink red the siren starts to sound and report about alarm is sending to nae CMS ortotheuser There are 2 ways to clear alarm and turnoff key 1 way by pressing the key and entering the PIN code Cm3 After the alarm clearing action is performed the siren stops sound the key backlight binking red goes off GOO the system status remains the same as was before alarm If the system has smoke detector and alarm was _ caused by smoke which was raised by domestic reasons the system will start alarm nevertheless it was armed or disarmed The only way to clear alarm is possible by bypassing of smoke detector see 2 page Bypassing zone v 2way by entering the PIN code After the alarm clearing action is
19. sarming of security barrier Pre Alarm mode ANS Microwave or infrared rays based security barriers also outdoor PIR detectors which are connected to the system can be armed by Pre Alarm mode The system will sound an alarm without sending alarm message to Central Monitoring Station when someone traverses this electrical barrier The Pre Alarm mode can be turned on and turned off by marking unmarking partitions with keys or by selecting CEN partitions with keys and marking unmarking with keys Pre Alarm Bypassing zone Bypassing a zone allows you to leave a door or window open while still arming the rest of your security Is system Bypass procedure can be made Zone bypass or and Zones Zones Zones 2 Hallway 2 Hallway 2 Hallway Kitchen 3 Kitchen Kitchen Bedroom Smoke detector Zones 1 x 2 Hallway Kitchen 3 3 4 Bedroom 4 Bedroom 4 5 5 3 4 Bedroom Smoke detector 5 Smoke detector 5 Smoke detector Zone isn t violated Zone is violated Zone is bypassed temporary Zone is bypassed permanently There are two different bypass types temporal or permanent First is used for one arming and disarming cycle second until the user unbypass the zone Enter the zone number you would like to bypass THIS MUST BE A TWO DIGIT NUMBER for the first zone 01 for second 02 and so on The zone will be marked by x
20. temperature can be hidden via the menu Settings m Keypad Settings Interface Settings Enter PIN DOO Show Temperature Trouble memory Keypad doesn t show the trouble memory with the slowly blinking Green color key LED by default If it is necessary to see trouble memory then the trouble memory showing can be enabled via the menu Settings Keypad Settings 9 Interface Settings Enter PIN OOOO Use Trouble memory amp In order to clear trouble memory user must press key review troubles and press key once again Hide troubles When the key is steady green the arming is impossible in usual way In order to arm the system user must to press twice the key The keypad starts to hide the trouble and key LED starts to blink fast During this time is possible to make usual arming procedure How long the keypad will hide the trouble depends on the setting of this menu No the trouble will be hidden only for 30 seconds Yes the trouble will be hidden until the trouble disappears example damaged battery will be replaced by new one Settings O Keypad Settings 9 Interface Settings Enter PIN m OMMOMO Hide Troubles Q PIN PIN PIN lenth If PIN length is fixed then the keypad automatically is pressing key after the last PIN digit is entered

Download Pdf Manuals

image

Related Search

armed armed forces travel armed forces bank armed forces vacation club armed forces day armed security jobs armed forces service medal armed and dangerous armed forces armed and dangerous lyrics armed and dangerous king von armed forces insurance armed forces bank login armed forces expeditionary medal armed forces reserve medal armed forces day 2025 armed forces vacation club website armed girl\u0027s machiavellism armed forces pacific armed incredibox armed conflict armed forces europe armed shark armed health armed forces auto insurance armed air forces pc

Related Contents

ワゴンRの    AquaPRO VIP50PRO Water Pump User Manual  Le dimanche entre le 30 octobre et le 5 novembre  User`s Manual  Descargar - ovm.go.cr  Einbauanleitung Installation Manual BMW 1er (F20) 09/2011  Finance – Tesouraria de Igreja Manual de instruções.  26234 - UNIVERSIDADE FEDERAL DO ESPIRITO SANTO 153050  Mode d`emploi pour le vernis colle Cléopôtre:  