Home

TUTA S30 - Oomipood

image

Contents

1. Add a family number 29 TUTA S30 GSM POWER SOCKET USER MANUAL 06 FamilyNumber 4 Add several family numbers 06 FamilyNumber1 FamilyNumber4 5 e FamilyNumber should be the Family users mobile phone number Successful SMS reply g Family numbers set successfully 3 1 6 Check family user s number Refer to Chapter 3 10 Check status 3 1 7 Delete family number Method The Master user sends following SMS message in order to Delete a family number 113 FamilyNumber 6 Delete several family numbers simultaneously 113 FamilyNumber1 FamilyNumber4 7 Delete all family numbers 113 8 Successful SMS reply 30 TUTA S30 GSM POWER SOCKET USER MANUAL Family number has been deleted amp Failed SMS reply g 4 The family number does not exist 3 2 Change password Method The Master user sends following SMS message in order to Change the password 04 O0 dpassword Newpassword 9 e The password is a four digit number e The original password is 1234 Successful SMS reply New password is 3 3 Switching on off the socket output manually LL Description e When the socket output is switching on TUTA S30 offers power supply for electronic appliance which being connected with it the red indicator light is lighted constantly Otherwise TUTA S30 has no power supply for electronic appliance and the red light is turned off e
2. 39 3 7 Temperature alarm esee 43 3 8 SMS notification upon the socket output changing 45 3 9 SMS notification upon external power supply Changlh9 46 3 10 Beep warning tone esse 47 Sil 1 CHECK StAtUs re e metet 48 3 12 Resetting the socket 50 TUTA S30 GSM POWER SOCKET USER MANUAL Chapter 4 Maintenancce sccsccsscsssssscssssssseessssessees 52 Chapter 5 General Troubleshooting 54 Chapter 6 Main Technical Parameters 57 Appendix SMS commands list eese 58 TUTA S30 GSM POWER SOCKET USER MANUAL 1 Purchase a GSM SIM card mobile phone card from GSM network service provider and install it in the socket This SIM card number is referred as TUTA S30 number on this brochure 2 The user needs to activate the Caller ID Presentation function of SIM card and deactivate PIN code of the SIM Contact with GSM network service provider for support 3 Change the original password at the beginning use Be sure to keep the password and SIM card number secret Do not disclose this information to anyone other than the authorized users in order to ensure your safety For your safety XA This socket was designed for home office use Do not use it on TUTA S30 GSM POWER SOCKET USER MANUAL the electrical appliance which is for industry or business operation for example iatrical ap
3. 3 1 Define the users 3 1 1 User authorization level All the settings of TUTA S30 can be set or adjusted via a SMS command There are two mobile phone user controlling levels Master user Only one Master user has authorization to use all features of TUTA 30 In order to enable all the functions on the socket the Master user must store his her mobile number in the socket s memory Only one Master s mobile number Master number is allowed for a socket Family users There are four Family users have authorization to use two commands of switch on or cut off the socket output 26 TUTA S30 GSM POWER SOCKET USER MANUAL The other mobile phone users have no authorization to use TUTA 30 3 1 2 About the SMS Command e Master user s SMS command format code content e Family users SMS command format code content password The password must be a four digit number e The original password is 1234 e The maximum digits that are allows for the phone number is sixteen e S30 will reply to the user after it receives the SMS command A Note e The symbol must not be ignored when typing an SMS command No allow any space within the commands 3 1 3 Add a master number to the socket LI Description If TUTA S30 is being used for the first time or TUTA S30 has been reset to factory settings the Master user s number must be programmed into the socket 27 TUTA S30 GSM POWER SOCKET USER
4. 38 After receiving the SMS commands TUTA S30 will reply one SMS message of Delayed switch on off the socket parameters checking Status ON OFF Output will switch off on after minutes Check Timing switch on the socket parameters 128 39 After receiving the SMS commands TUTA S30 will reply one SMS message of Timing switch on the socket parameters Schedule control function ON OFF WorkDay StartTime EndTime Check Temperature control parameters 159 40 After receiving the SMS commands TUTA S30 will reply one SMS message of temperature parameters checking Status ON OFF Temp control function ON OFF Temp Mode Heating Cooling Range LowTemp HighTemp If No temperature sensor connected be received it means TUTA S30 cannot detect the temperature sensor User needs to check if the temperature sensor is inserted to the I O port 49 TUTA S30 GSM POWER SOCKET USER MANUAL Check temperature rapid changing alarm parameters 160 41 After receiving the SMS commands TUTA S30 will reply one SMS message of parameters It means SMS alarm message will be sent upon the surrounding temperature changes Delta centigrade degree within minutes Fast temperature changing function ON OFF Delta Time minutes Check over temperature alarm limits parameters 170 42 After receiving the SMS commands TUTA S30 will reply one SMS message of parameters It means SMS a
5. Default p 32 12 1 No SMS notification 33 12 0 upon the power supply changing 34 35 Check status Check socket 36 07 operating status 63 TUTA S30 GSM POWER SOCKET USER MANUAL Category Function Command Check Socket output 37 000 Check Delayed switch 38 138 on off the socket parameters Check Timed switch 39 128 on the socket parameters Check Temperature 40 159 control parameters Check temperature 41 160 rapid changing alarm parameters Check over 42 170 temperature alarm parameters Reset to factory Reset the socket 43 08 settings 64 TUTA S30 GSM POWER SOCKET USER MANUAL TUTA S30 GSM Power Socket TUTA S30 GSM POWER SOCKET USER MANUAL E1046 66
6. right to make changes and improvements to any of the sockets described in this document without prior notice For the latest socket information please visit http www i tuta com We don t guarantee for the document veracity reliability or any content except regulate in proper laws Including no guarantee for socket suitable market or suitable area promise We hold no responsibility for the illegal use of this socket We hold no responsibility for any loss of income or any special incidental consequential or indirect damages howsoever caused The contents of this document are provided as is Except as required by applicable law no warranties of any kind either TUTA S30 GSM POWER SOCKET USER MANUAL expressed or implied including but not limited to the accuracy reliability or contents of this document We reserve the right to revise this document or withdraw it at any time without prior notice TUTA S30 GSM POWER SOCKET USER MANUAL Chapter 1 Features and accessories 1 1 Main function This socket uses a GSM SIM card Remotely operate by SMS command The socket be controlled and set by sending SMS commands Input 110V 250V 50Hz Output Max 16A for long duration operation Relay 30A 250V relay with two working status power on off for output outlet M button To manual control output power on off Delayed control socket output Auto operates by preset schedule Fixing time control o
7. MANUAL Method The user must edit and send the following SMS to socket via his her mobile phone the phone number will be the Master number in order to Add a master number to the socket 00 2 Successful SMS reply Welcome to use TUTA S30 Your Password is 1234 amp Failed SMS reply If a user tries to add another Master user again TUTA S30 will send a notification via SMS stating The master user already exists The Master number should be changed Refer to Chapter 3 1 4 3 1 4 Change the master number Method Method 1 The Master user sends following SMS message in order to Change the master user s number 144 NewMasterNumber 3 28 TUTA S30 GSM POWER SOCKET USER MANUAL e NewMasterNumber should be the new Master user s mobile phone number Method 2 TUTA S30 should be reset to factory settings to remove old Master number before setting the new one Refer to Chapter 3 11 Successful SMS reply New master number set successfully Successful SMS reply will be sent to the new Master user Then the old Master user s number will not be able to control TUTA S30 anymore 3 1 5 Add a family number Up to 4 family users number can be stored on one socket Family users have the authority to send SMS command to switch on or cut off the TUTA S30 output The family users should remember and safeguard the socket s SIM number Method The Master user sends following SMS message in order to
8. Note If the socket output status is changed manually including 31 TUTA S30 GSM POWER SOCKET USER MANUAL pressing the M button sending SMS making phone call the preset timing delaying or temperature control of the socket will be invalid automatically and a SMS notification message will be sent to the Master but the setting time range and temperature range parameters will be saved until TUTA S30 is reset to factory settings 3 3 1 Switching on off by SMS Method The Master user sends following SMS message in order to Switch on the socket output manually 01 10 Cut off the socket output manually 02 11 The Family users send following SMS message in order to Switch on the socket output manually 01 Password 12 Cut off the socket output manually 02 Password 13 e Password should be 4 digits password number Default 1234 e SMS reply will be also sent to Master user when Family users use these two commands to change the socket output successfully Successful SMS reply Status ON OFF Temp Temp control function ON OFF 32 TUTA S30 GSM POWER SOCKET USER MANUAL Schedule control function ON OFF Delay control function ON OFF 3 3 2 Switching on off by M button Keep press M button on the TUTA S30 for half a second The OUTPUT indecator light will turn on or off to indicate that TUTA S30 output is switching on or off The SMS reply is same with Chapter 3 2 1 3 3 3 Switching on off by calli
9. Saturday 7 Everyday 8 Monday to Friday e StartTime and EndTime Be consists of 4 digits hh mm and works on a 24 hour clock The StartTime and EndTime should be in the same day and the EndTime must be later than StartTime e The socket output will switch on at the StartTime and cut off at the EndTime e For example 129 1 0000 2130 0000 means time 00 00 hh mm AM 2130 means time 9 30PM 38 TUTA S30 GSM POWER SOCKET USER MANUAL Successful SMS reply Schedule control function ON OFF WorkDay StartTime EndTime 3 5 3 Disable timing switching on the output Method The Master user sends following SMS message in order to Disable timing switch on the output 128 0 20 Successful SMS reply Schedule control function OFF WorkDay StartTime EndTime 3 6 Auto control the socket output by temperature 3 6 1 Enable auto controlled by temperature Description e The external temperature sensor must be inserted into the I O port of TUTA S30 The output status of the socket can be controlled by the environmental temperature automatically e If users don t open the timed switch on the socket or delayed switch on off the socket functions the socket will control to switch 39 TUTA S30 GSM POWER SOCKET USER MANUAL on or cut off the output according to temperature setting e f users open the timed switch on the socket or delayed switch on off the socket functions the temperature cont
10. T USER MANUAL Category Timing control Temperature control Function Delay switching off the output after a certain minutes Enable timing switch on the output Set time period to switch on the output Disable timing switch on the output Enable auto control the output by temperature Set temperature range to switch on off the output Disable auto control the output by temperature Enable the over 24 170 1 61 Command 17 138 0 Minutes 18 128 1 19 129 WorkDay StartTime EndTime 20 128 0 21 159 1 22 159 Mode LowTemp HighTemp 23 159 0 TUTA S30 GSM POWER SOCKET USER MANUAL Category Function Command temperature temperature alarm SSS alarm Set limits of 25 170 MinTemp temperature MaxTemp Disable the over 26 1 70 0 temperature alarm Temperature Enable the 27 160 1 rapid temperature rapid changing changing alarm alarm Set time period and 28 160 Temp Time temperature changing value Disable the 29 160 0 temperature rapid changing alarm SMS notification upon SMS the socket output notification changing Default 62 TUTA S30 GSM POWER SOCKET USER MANUAL Category Function Command upon the socket output SMS notification upon the power supply changing Default Beep Enable the Beep 19 1 warning tone warning tone Disaable the Beep 35 19 0 warning tone
11. TUTA S30 GSM Power Socket HE aN AA N TUTA S30 GSM POWER SOCKET USER MANUAL N Manual version 1 2 TUTA S30 GSM POWER SOCKET USER MANUAL TUTA S30 GSM Power Socket Thank you for purchasing the TUTA S30 The TUTA S30 GSM power socket is a remote controlled socket consisting of a GSM module The power supply output of the socket can be turned on or off remotely by the SMS Short Message System command or local controlled by pressing button It is an intelligent power supply socket controlled by users mobile phone at anytime and anywhere TUTA S30 is suitable for controlling electrical appliances which power consumption less than 3000W in household or office It is universal for all kinds of indoor power supply sockets With extended connected temperature sensor TUTA S30 can switch on or off the socket outpu t according to the environment temperature It s available for power control of the heating or refrigeration plant to keep the environmental temperature within presetting range or at a fixed temperature value Furthermore a SMS notification will be sent to master s mobile phone if TUTA S30 detects the rapid changing or the TUTA S30 GSM POWER SOCKET USER MANUAL reaching of pre set alert value of surroundings temperature TUTA S30 is mainly applied for house and office usage It is not suited for industry application especially in humidity or dust cond
12. ch off the socket output 02 Successful SMS reply Status ON OFF Temp Temp control function ON OFF Schedule control function ON OFF Delay control function OFF 2 6 External power supply notification TUTA S30 will notify the user when the external power changes The Beep Beep tones will be heart if enabled also a SMS notification will be sent if the SIM card is available Lost external power supply If the plug of TUTA S30 is disconnected from external AC power or lost of the AC power occurs all operating on TUTA S30 is de activated including M button and all SMS commands TUTA S30 will notify the 24 TUTA S30 GSM POWER SOCKET USER MANUAL user Main electricity supply lost Temp Resume external power supply If the AC power of TUTA S30 is available again the SMS notification will be sent to the user i e Main electricity supply restore Status ON OFF Temp When the external power supply is resumed the output of TUTA S30 will keep its previous working status For example if the output is switched on before the external power supply cut off the output will be switched on when the external power supply is resumed If the power supply is switched on and off frequently TUTA S30 will send reminding SMS messages The SMS notification upon external power supply changing can be disabled Refer to Chapter 3 8 25 TUTA S30 GSM POWER SOCKET USER MANUAL Chapter 3 Advanced settings
13. changing alarm 160 1 27 Set time period and temperature changing value 160 Temp Time 28 e Temp The values lie in the range of 1 to 50 centigrade degree e The values lie in the range of 1 to 300 minutes e Default Temp is 2 degree and Time is 1 minute Disable the temperature rapid changing alarm 160 0 29 Successful SMS reply Fast temperature changing function ON OFF Delta Time minutes 3 8 SMS notification upon the socket output changing Description TUTA S30 will default notify the user when the state of the socket output is changed with a SMS notification The Master user can enable disable this SMS notification 45 TUTA S30 GSM POWER SOCKET USER MANUAL Method The Master user sends following SMS message in order to SMS notification upon the socket output changing Default 1188 30 No SMS notification upon the socket output changing 211808 31 Successful SMS reply Set no SMS notification when socket output changed Set SMS notification once socket output changed 3 9 SMS notification upon external power supply changing Description TUTA S30 will default notify the user when the state of the external power supply is changed with a SMS notification For example Main electricity supply lost Temp or Main electricity supply restore 46 TUTA S30 GSM POWER SOCKET USER MANUAL Status ON Temp The Master user can enable disable this SMS not
14. eived and if the the socket output is switched on the socket output will remain the switch on state and be switched off as the setting delayed time is reaching If the socket output is switched off it will be switched on immediately and be switch off again when reaching the setting delayed time After switching off the socket output the following SMS reply will be sent Status OFF Delay control function OFF Method The Master user sends following SMS message in order to Delay switching on the output after a certain minutes 138 1 Minutes 16 Delay switching off the output after a certain minutes 138 0 Minutes 17 e Minutes are time parameters its range is 0 720 e When Minutes is 0 the delayed switch on off the socket function will be invalid but the current output status won t be changed Successful SMS reply 35 TUTA S30 GSM POWER SOCKET USER MANUAL Status ON OFF Output will switch off on after minutes 3 5 Timed switching on the socket output 3 5 1 Enable timing switching on the output LL Description e The output of TUTA S30 can be set to switch on for a duration and then be switch off after the duration e If the socket output status is changed manually including pressing M button sending SMS and making phone call the preset timing delaying or temperature control of the socket will be invalid automatically but the setting time range parameters will be saved until TUTA S30 is reset to fact
15. ess mode 1 For warmness mode 0 e LowTemp and HighTemp means temperature value the range is 10 to 50 centigrade degree if LowTemp equals to HighTemp constant temperature control will be actived 4l TUTA S30 GSM POWER SOCKET USER MANUAL e Temperature unit is degree Celsius e Example 1 set commands 159 0 10 20 if the environmental temperature is 5 degrees bellow the limitation of 10 degrees in the command the socket output will be switched on to power heating apparatus and if the environmental temperature is 24 degrees above the limitation of 20 degrees in the command the socket output will be switched off and the heating apparatus stops working e Example 2 set commands 159 1 10 20 if the environmental temperature is 26 degrees above the limitation of 20 degrees in the command the socket output will be switched on to power cooling apparatus and when the environmental temperature is 7 degrees bellow the limitation of 10 degrees in the command the socket output will be off cooling apparatus stops working Successful SMS reply Status ON OFF Temp control function ON OFF Temp Mode Heating Cooling Range LowTemp HighTemp 42 TUTA S30 GSM POWER SOCKET USER MANUAL 3 6 3 Disable auto controlled by temperature Method The Master user sends following SMS message in order to Disable auto control the output by temperature 159 0 23 Successful SMS reply Status ON OFF Temp contr
16. ification Method The Master user sends following SMS message in order to set SMS notification upon the power supply changing Default 12 1 32 No SMS notification upon the power supply changing 12 0 33 Successful SMS reply No SMS notification upon main electricity supply changing 3 10 Beep warning tone LI Description A Beep warning tone will be sounded if the work state of TUTA S30 is changed The Beep warning tone is default turning off The Master user can enable it by sending SMS command Method The Master user sends following SMS message in order to Enable the Beep warning tone 19 1 34 Disaable the Beep warning tone Default 19 0 35 47 TUTA S30 GSM POWER SOCKET USER MANUAL Successful SMS reply Beep alarm activated de activated 3 11 Check status Method The Master user sends following SMS message in order to Check socket operating status 07 36 After receiving the SMS commands TUTA S30 will reply one SMS message of socket status checking Number eee Status ON OFF TEMP Temp control function ON OFF Schedule control function ON OFF Delay control function ON OFF Check socket output status 000 37 After receiving the SMS commands TUTA S30 will reply one SMS message of socket output status Status ON Temp 23 48 TUTA S30 GSM POWER SOCKET USER MANUAL Check delayed switch on off the socket parameters 138
17. ition All services and functions need to be supported by the GSM network and a SIM card This brochure suits for TUTA S30 model Details of the functioning and advanced operation of this socket are described in this instruction manual TUTA S30 GSM POWER SOCKET USER MANUAL CONTENT For your safely deret 8 Exception ene 10 Chapter 1 Features and 1 12 1 1 Main function sse 12 1 2 Package contents ccce 14 1 3 Sockets instructions 16 1 4 Light indicator and Beep warning tone 18 Chapter 2 Quick Start sccscssccsescstssctsesceessstesseees 20 2 1 Install the SIM card and temperature sensor 20 2 2 GSM Power on off sse 21 2 3 Add a Master number to the socket 22 2 4 The regulation of time sse 23 2 5 Socket output switching on off sss 23 5 TUTA S30 GSM POWER SOCKET USER MANUAL 2 6 External power supply notification 24 Chapter 3 Advanced settings eere 26 3 1 Define the users 26 3 2 Change password sss 31 3 3 Switching on off the socket output manually 31 3 4 Delayed switch on off the socket output 34 3 5 Timed switching on the socket output 36 3 6 Auto control the socket output by temperature
18. ket External temperature 10 C 50 C sensor GSM working band EGSM900 DCS1800 57 TUTA S30 GSM POWER SOCKET USER MANUAL Appendix SMS commands list Category Function Command Time Regulate the socket 1 time 1524 SIMCardNumber Define the Add a master number users to the socket 58 TUTA S30 GSM POWER SOCKET USER MANUAL Category Switching on off output manually Function Change the master user s number Command 3 14 NewMasterNumber Add a family number 4 06 FamilyNumber Add several family numbers Delete a family number Delete several family numbers simultaneously Delete all family numbers Change the password Master user switches on the socket output manually Master user cuts off the socket output 59 5 06 FamilyNumber1 ZFamilyNumber4t 6 113 FamilyNumber 7 113 FamilyNumber7 FamilyNumber4 9 04 0 Newpassword 10 01 11 O2 TUTA S30 GSM POWER SOCKET USER MANUAL Category Function Command Family user switches 12 01 Password on the socket output manually Family user cuts off 13 02 Password the socket output manually Enable switching on off the output by calling Disable switching 15 18 0 on off the output by calling Default Delay control Delay switching on the 16 138 1 Minutes output after a certain minutes 60 TUTA S30 GSM POWER SOCKE
19. larm message will be sent upon temperature reaches MinTemp or MaxTemp centigrade degree Temperature alert function OFF Min Temp Max Temp 3 12 Resetting the socket Description e This function resets all programmed settings to their original values 50 TUTA S30 GSM POWER SOCKET USER MANUAL including cleaning all user number timing parameter temperature parameter If the setting status is wrong or the malfunctions can t be corrected users can restore the socket to its original status to make it work normally Note This function needs to be used carefully as it also erases all setting values Method Method 1 Press the side M button of the device for 5 seconds Method 2 The Master user sends following SMS message to TUTA S30 in order to Reset the socket 08 43 Successful SMS reply Reset the socket to factory setting successfully A long Beep tone if enabled will be heard and it means resetting the socket successfully 51 TUTA S30 GSM POWER SOCKET USER MANUAL Chapter 4 Maintenance e lf TUTA S30 does not in use for long time it should be powered off e Store and use the remote socket in suitable temperature Too high or too low temperature will likely to damage the socket e to keep the TUTA S30 and all its accessories dry Do not store and use it in the bathroom or other place with high humidity Do not allow pour water or other
20. liquids into the socket otherwise it might cause malfunctions e Do not store and use the socket in dusty e Do not use alcohol acetone and other similar solvents to clean it Wipe it with soft wet cloth 52 TUTA S30 GSM POWER SOCKET USER MANUAL Do not attempt to open it except as instructed If the socket does not work normally try to resolve it as the guide of the general troubleshooting if to the problem can not be solved contact with the dealer immediately 53 TUTA S30 GSM POWER SOCKET USER MANUAL Chapter 5 General Troubleshooting General Trouble Power indicator light turns off GSM indicator light turns off Socket output cannot be changed by M button Possible Reason No power input Can t find or identify the SIM card The power switch is OFF No power input The power switch is OFF 54 Solution Check TUTA S30 s external AC power is available SIM card no install properly Power off the socket and check it again Power on the socket Check TUTA S30 s external AC power is available Power on the socket TUTA S30 GSM POWER SOCKET USER MANUAL General Trouble All functions disable Indicator is working Socket didn t response of any operation After power on the socket GSM indicator keeps flashing Possible Reason Caller ID presentation do not active insufficient fee of the SIM card TUTA S30 work abnormally Netw
21. ng 2 Description If the Master user calls TUTA S30 the socket output will be Switched on or cut off automatically when the user hears the ring tone in the phone The calling will be hung up automatically if the user doesn t hang up the call Method The Master user sends following SMS message in order to Enable switching on off the output by calling 18 1 14 Disable switching on off the output by calling Default 33 TUTA S30 GSM POWER SOCKET USER MANUAL 18 0 15 Successful SMS reply Control the socket power output status by calling activated de activated 3 4 Delayed switch on off the socket output LL Description e The output of TUTA S30 can be set to delay switch on or off for a period with SMS commands e When the delayed switch on off the socket function is applied the preset timed switch on the output function will be invalid at once e When the delayed switch on the socket command is received and if the socket output is switched on the socket output will be switched off immediately and be switch on again as the setting delayed time is reaching Contrarily if the socket output is switched off the output will remain switching off until the setting delayed time is reaching Afther switching on the output the following SMS reply will be sent Status ON 34 TUTA S30 GSM POWER SOCKET USER MANUAL Delay control function OFF e When the delayed switch off the socket command is rec
22. ocket feature Therefore before using the user should ensure that TUTA S30 is used in an area with a strong GSM network signal e For the first time use the user should perform a test run by sending SMS to the socket This allows the user to check the GSM network connection of the socket 2 3 Add a Master number to the socket The user must edit and send the following SMS to socket via his her mobile phone the phone number will be the Master number in order to Add a Master number to the socket 00 Successful SMS reply Welcome to use TUTA S30 Your Password is 1234 22 TUTA S30 GSM POWER SOCKET USER MANUAL 2 4 The regulation of time A Important note If TUTA S30 is being used for the first time or it has been reset the Master user must adjust the socket time according to the current time of SMS center Otherwise TUTA S30 will use the original time from 00 00 00 1 2004 Method The Master user sends following SMS message in order to Regulate the socket time 152 S MCardNumber 1 e The SIMCardNumber should be the SIM card number of TUTA S30 Successful SMS reply The socket current time is yyyy mm dd hh mm 2 5 Socket output switching on off Method Method 1 To press M button 0 5 second See on Figure 23 TUTA S30 GSM POWER SOCKET USER MANUAL Method 2 The Master user sends following SMS message to socket in order to Switch on the socket output 01 Swit
23. ol function OFF Temp Mode Heating Cooling Range LowTemp High Temp 3 7 Temperature alarm 3 7 1 Over temperature alarm Description A range of temperature can be pre set onto the socket In this case if the surroundings temperature is detected out of the pre set temperature range the TUTA S30 will auto send the SMS alarm message to master s mobile phone This feature depends on the temperature sensor 43 TUTA S30 GSM POWER SOCKET USER MANUAL Method The Master user sends following SMS message in order to Enable over temperature alarm 170 1 24 Set limits of temperature 170 MinTemp MaxTemp 25 e MinTemp and MaxTemp The values can be set within the range of 10 to 50 centigrade degree Default MinTemp is 20 and MaxTemp is 30 centigrade degree Disable the alarm upon going beyond limits temperature 8170808 26 Successful SMS reply Temperature alert function ON OFF Min Temp Max Temp 3 7 2 Temperature rapid changing alarm Description A time period value and temperature changing value can be pre set onto the socket In this case if the surroundings temperature change to the pre set value within the pre set time period a SMS alarm message will be auto sent to master s mobile phone 44 TUTA S30 GSM POWER SOCKET USER MANUAL This feature depends on the temperature sensor Method The Master user sends following SMS message in order to Enable the temperature rapid
24. ork signal weak or network busy 55 Solution Contact network provider to active SIM card function Pay for the card Switch off the power check SIM card or reset factory setting If mobile phone s signal is weak too place the socket at other place with strong signal and try again TUTA S30 GSM POWER SOCKET USER MANUAL General Possible Reason Trouble SIM card PIN code actives SIM card invalid The master Other master is number already set in the already socket exists Invalid Invalid command format Please check and try again No authorization user Solution Close the PIN code Contact with local operator to check of it Change Master number or recover to factory default setting Refer to the user manual Use the Master mobile phone to try the command again Note If the problem can t be solved with above guidelines contact to your local distributor or after service center 56 TUTA S30 GSM POWER SOCKET USER MANUAL Chapter 6 Main Technical Parameters Input power socket 110 230V 50HZ CEE 7 7 hybrid Schuko French plug Output power socket 110 230V 50HZ 230V 30A 30s 16A long duration CEE7 4 German Schuko Operating temperature 10 C 50 C Store temperature 20 C 60 C Relative humidity 10 90 without condensation Communication GSM PHASE 2 2 protocols including data operation Data interface GSM SIM 1 8V 3 0V soc
25. ory settings If these functions need to be restarted the following SMS commands must be set Timing 3128212 Temperature control 159 1 delayed switch on off the Socket commands need to be reset Method The Master user sends following SMS message in order to Enable timing switch on the output 128 1 18 36 TUTA S30 GSM POWER SOCKET USER MANUAL Successful SMS reply Schedule control function ON WorkDay StartTime EndTime If the value of the WorkDay StartTime EndTime on the SMS reply are all 0 it means the time duration has not been set Refer to 3 4 2 Then TUTA S30 will keep switching on or off the output automatically according to the schedule settings 3 5 2 Set time period to switch on the output Description After successful setting of time duration to switch on the socket output the schedule parameter will be saved on the socket until TUTA S30 is reset to factory settings But the timed switch on the output feature is applied only when command 17 be set Method The Master user sends following SMS message in order to Set time period to switch on the output 129 WorkDay StartTime EndTime 19 37 TUTA S30 GSM POWER SOCKET USER MANUAL e WorkDay one digit the values lie in the range of 0 to 8 The following table contains the descriptions of each value Value Corresponding day 0 Sunday 1 Monday 2 Tuesday 3 Wednesday 4 Thursday 5 Friday 6
26. pliances large heaters and refrigerates Before using this socket make sure that the mobile phones can be used well in the area otherwise do not put this socket into operation The power consumption of the appliances connected with the socket cannot exceed 3000W and the current cannot exceed 16A The electrical appliance which power consumption is higher than 1500W must be grounded Do not make two plugs of socket short circuit Do not touch the socket jack by any metal objects or hand This socket was designed for indoor use Don t use it in wet chemically aggressive or dusty environment Do not open the case unless maintenance needed Do not keep shaking or fall down this socket otherwise it can be damaged This socket is a wireless signal transmission socket Keep it away from electronic equipment likely to interfere with the wireless signals in order to avoid signals interference Switch off this socket and mobile phone when entering areas marked Explosive Might explode Closed wireless transceiver 9 TUTA S30 GSM POWER SOCKET USER MANUAL sockets etc Do not cast this socket in a fire as this may cause explosion This socket should only be operated from power approved by the socket manufacturer The use of any other types of power may damage the socket Keep the socket and its accessories out of the children reach Exception clause 1 We operate on a policy of continuous development We reserve the
27. rection The SIM card will be fixed in the holder A Screw the SIM cover back A Insert the temperature sensor into the I O port until it is seized 20 TUTA S30 GSM POWER SOCKET USER MANUAL 2 2 GSM Power on off Power on 1 Turn the power switch to On position See 7 on Figure 2 Plug the TUTA S30 in an AC power socket See 6 on Figure The blue light will be flashing slowly for about 20 seconds then blue light be on constantly and a long Beep tone can be heard if Beep warning tone is enabled The default state of the socket outlet is no power supply output 3 Insert the plug of electronic appliance in the TUTA S30 electrical outlet See 4 on Figure 4 M button See 3 on Figure1 can be pressed for about 0 5 second to switch on or off the output of socket After adding user numbers to the socket users can send SMS command to control the power supply output Refer to Chapter 3 2 Power off 1 Turn the power switch to Off position The blue light turns off 2 The socket outlet can work as a normal power socket TUTA S30 can not be controlled by SMS commands M button is disabled A Note 1 If the GSM indicator light is not constant lights which imply 21 TUTA S30 GSM POWER SOCKET USER MANUAL the SIM card working abnormally all functions of this socket are invalid 2 Check GSM network signal of the using place e The GSM network s signal strength may affect the s
28. rol function will only be valid when power output is switch on including timed switch on or delayed switch on time period e For example S30 is used for the power control of the heating apparatus If users set the socket output on when indoor temperature is bellow 20 degrees and off when indoor temperature is above 28 degrees Meanwhile users set the TUTA S30 output is on from 9am to 5pm In this case the socket will control to switch on or off the output according to indoor temperature automatically from 9am to 5pm duration Method The Master user sends following SMS message in order to Enable auto control the output by temperature 159 1 21 Successful SMS reply Status ON OFF Temp control function ON Temp Mode Heating Cooling Range LowTemp HighTemp 40 TUTA S30 GSM POWER SOCKET USER MANUAL Then TUTA S30 can switch on or off the output automatically according to the temperature range setting 3 6 2 Set temperature range to switch on off the output LI Description After successful setting of temperature range the temperature parameter will be saved on the socket until TUTA S30 is reset to factory settings But the Auto controlled by temperature feature is applied only when command 20 be set Method The Master user sends following SMS message in order to Set temperature range to switch on off the output 159 Mode LowTemp HighTemp 22 e Mode is the control selection For coldn
29. uction 1 4 Light indicator and Beep warning tone Indicator Action Status Green light Constant Has power supply input light GSM Blue Turning off Not installed SIM card or the power light switch of socket is OFF Be busy or searching GSM network Constant Successfully load to GSM network light Output Red Constant The socket outlet has power supply light light TUTA S30 GSM POWER SOCKET USER MANUAL pf Turing oft The socket outlet cuts power supply Beep One time The socket outlet changes power warning tone supply status Default Several TUTA S30 lost external power supply turning off times Long Beep TUTA S30 is successfully register GSM network or it is successfully reset to its factory settings Note The Beep warning tone can be turn on or turn off by SMS command Refer to Chapter 3 9 for details TUTA S30 GSM POWER SOCKET USER MANUAL Chapter 2 Quick start 2 1 Install the SIM card and temperature sensor A Turn the power switch to OFF position Loosen the screw and open the socket s SIM cover you will see a SIM card holder A Push the metallic cover of the holder to OPEN direction and open the SIM card holder A Put the SIM card on the card holder ensuring that the beveled corner is toward the beveled corner of the SIM holder and the golden contact area is facing downwards A Cover back the metallic cover and push it to LOCK di
30. utput power on off External temperature sensor supported Send environmental temperature SMS to mobile phone Auto operates by temperature Available for power control of the heating or refrigeration plant to keep the environmental TUTA S30 GSM POWER SOCKET USER MANUAL gt temperature within presetting range or at fixed temperature value SMS alarm when temperature rapid changing or reaching the pre set value When it detects the rapid changing or the reach of pre set alert value of surroundings temperature it can auto send the SMS alarm message to master s mobile phone Support 5 mobile phone users Auto time synchronization SMS notification upon external power source changing TUTA S30 GSM POWER SOCKET USER MANUAL 1 2 Package contents GSM power socket 1 unit TUTA S30 GSM Power Socket TUTA S30 GSM POWER SOCKET USER MANUAL Temperature sensor 1 unit User manual 1 unit TUTA S30 GSM POWER SOCKET USER MANUAL 1 3 Sockets instructions TUTA S30 GSM POWER SOCKET USER MANUAL Data port Temperature sensor port M button Electrical outlet ndicator light Power GSM Output Q Socket plugs ri Power switch card holder Figure 1 TUTA S30 instructions 17 TUTA S30 GSM POWER SOCKET USER MANUAL Temperature sensor Standard 3 5mm interface put into 2 of Figure1 Figure 2 Temperature sensor Instr

Download Pdf Manuals

image

Related Search

Related Contents

Wand-Terminal Wall terminal Terminal mural  User`s Manual Manual del Usuario 使用手册  MODE D`EMPLOI - DAEWOO Electronics France  LED Realbeam 4 RGBW  Upper & Lower Oven  中央会計隊 契約科長 菅 谷 次のとおり一般競争入札を行います。入札  3 ANS !  äMOÇMADLS r, ` & W Enrelech  PowerFlex 753 Drives - Literature Library  Fujitsu ESPRIMO P9900  

Copyright © All rights reserved.
Failed to retrieve file