Home
BL-400S BLACKLIGHT USER MANUAL - Techni-Lux
Contents
1. and unscrew the lamp replacement cover Only use the appropriately rated lamps as use of any other lamp type many cause the unit to be non operational Due to the nature of the mercury vapor discharge lamp it is vitally important that you do not touch the new replacement lamp with your bare fingers as this will reduce lamp life considerably Once again a clean tissue or cloth can be used for fitting the replacement lamp After replacement of the lamp if the unit is still not working then please contact your local dealer or our company for assistance CLEANING The most important part of maintaining lighting fixture is to keep it clean By keeping the reflector clean it will allow more light to be transmitted amp projected forward thus producing a better UV effect and cooler operation This should be cleaned with a soft damp cloth The body of the unit may also be cleaned in the same way Make sure all vents are free of debris and ventilation obstructed in any way Any internal cleaning should be performed by a fully qualified technician MAINTENANCE amp SERVICING Any work on internal parts should be carried out by a qualified technician only Removal of covers other than the front to replace lamp is considered a breach of warranty and will not be covered under any such agreement unless authorized first by our company TROUBLESHOOTING e Ifthe unit is not functional check main power supply is on and at the correct voltage e I
2. _ ZO Technt lux BL 400S BLACKLIGHT USER MANUAL INTRODUCTION Thank you for purchasing the BL 400S UV Blacklight It is a high power 400w spot UV producing fixture To assist with the care and proper use of the product we have prepared this user manual Read it carefully prior to use OPERATION Before connecting this unit to the mains power supply for the first time you must first install the lamp See Replacing Lamp for details This lighting effect has been designed to function on a mains power supply at 120V 60Hz and has been fitted with a suitable Edison NEMA 5 15 power plug for use with your local 120 voltage Check the label on the unit and the power plug for the correct voltage It must be connected to an On Off type circuit without DIMMING Powering this fixture from a DIMMER will damage the magnetic ballast and electrical system When connected to the mains power supply the unit should illuminate The product utilizes a high intensity mercury vapor lamp it will take 5 to 10 minutes to reach full intensity The intensity of the lamp will increase with use The light emitted by the product is invisible and does not have the glow of a fluorescent fixture It produces UV radiation Due to the high operating temperature of discharge mercury lamps it is advisable that the effect be used in well ventilated areas and making sure not to obstruct the air vents To maximize lamp life allow the unit to cool down before moving or
3. f the unit is functional but lamp does not light lamp may require replacing e Ifthe unit lights up but it not very bright lamp maybe very old and requires replacement or unit is not receiving proper voltages Make sure unit is not plugged into any dimming device POWER CONNECTIONS The unit is supplied with an Edison power plug appropriate to its voltage Should any other connections be required they must be carried out with the following configuration Earth Green Yellow cable Common Neutral Blue cable Hot Live Brown cable In the USA amp Europe it is required that all plugs are 3 pin type i e with Earth Ground connection In the UK it is required that all mains plugs are fitted with 5A fuses TECHNICAL SPECIFICATIONS Power 120V 60Hz AC Fuse TAN25V Lamp LH400BL T 400W E40 Dimensions 352x380x390mm Weight 12 7KG Warranty Limited 90 day warranty
4. touching the lamp CAUTION Do not obstruct the air vents Do not touch unit or lamps while hot Never put any objects through the air grill or on top of the unit No user serviceable parts inside please refer to our company Due to the nature of the mercury vapor lamp this lamp must be allowed to cool down about 5 to10 minutes after being turned off before attempting to reignite Failure to wait for cool down may cause the lamp to fail prematurely This unit gets very hot and must not be within reachable touch This unit produces UV light which could be harmful if exposed to for extensive periods It may cause burns Do not stare into the unit INSTALLATION MOUNTING Although this unit can be used in an upright position it is recommended that for safety purposes your lighting effect be properly mounted using a suitable hanging clamp and safety cable We offer a range of items which are ideal for safe mounting Do not mount near flammable products Keep at least 1 meter away Use in a well ventilated area without obstruction to air vents Do NOT allow this unit touch other products or materials REPLACING LAMP 1 Disconnect from main power supply before attempting to replace the lamp 2 Ensure that the unit is sufficiently cool before removing blown lamps _ HZO Techni lux 3 Never touch new lamps with your fingers use a tissue or a cloth In order to replace the lamp disconnect from main power supply first
Download Pdf Manuals
Related Search
Related Contents
Phonix S7505TFB mobile phone case Manual - Generex none 554200 Use and Care Manual GTO-804EZ/GTO-504EZ PSS User Guide - To Parent Directory Bedienungsanleitung Mode d'emploi Operating instructions Hunter Fan 21970 Fan User Manual GATOR® ES1000 Battery-powered Cable Cutter Copyright © All rights reserved.
Failed to retrieve file