Home
TwisTorr 84 FS AG Rack Controller User Manual
Contents
1. S IT OP H z F IR JO IN IT If the pump is not connected the display will be as follows CIHJE K N EICI IT I OI N T O U M P a Pressing the START button the pump is started and the display shows the following screen page SIT A R T X X X X H z F R NIT DO TwisTorr 84 FS AG Figure 32 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 253 297 17 Technical Information This screen page will be visible throughout the acceleration phase the pump The increasing value of the rotation freguency will be displayed in the boxes marked X the user may decide to express this value in Hz default or in KRMP Once operating speed has been reached the following screen page is displayed NIO R M A L 9 6 3 HI z VACUUM TECHNOLOGIES DO previous START STOP TwisTorr 84 FS AG O Figure 33 The following screen page is displayed on reaching the pre established speed 254 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Technical Information 17 The rotation value set in both NORMAL and LOW SPEED mode can be modified by
2. Check connection between controller and pump then press STOP push button twice to start the pump If the P1 input connector is not in position with the link or the external interlock connections are open when the START pushbutton is pressed the display will be as shown in the following figure at dI I N T E R L O C K Disconnect connector P1 and check the link or the external interlock then install the connector to start the pump If within each step of the soft start mode the rotational speed of the pump do not reach the planned value within 15 minutes the display will be as shown in the following figure 288 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Technical Information 17 If in normal operation after the starting phase the current drawn by the pump is higher than programmed 1 8 A the pump and the inter connected devices are switched off and the display will be as shown in the following figure T0 0 HIGH L 0 A D Verify that systems has no leaks than press STOP RESET pushbutton twice to start the pump Check that pump rotor is free to rotate then press the STOP RESET pushbutton twice to start the pump If the upper bearing pump temperature exceeds 60 C the pump is shut off and the display will be as shown in the following figure P U M P O V E R T E M P
3. Figure 3 Controller TwisTorr 84 AG Rear panel 1 Logic input signals connectors mating connector supplied with link 2 Logic output signals connector and pump frequency monitor plus programmable analog output Power output connector 24 Vdc for pump cooling fan Vent Valve and Gauge Controller power entry module consisting of mains fuses mains socket and EMC filter Rotary switches for Profibus address setting Profibus Optional Remote control serial connector il B w Pump cable 5m long 202 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Instructions for Use 16 Use Procedure Controller Startup To startup the controller plug the power cable into a suitable power source Starting the Pump To start the pump confirm the interlock input and press the START pushbutton on the controller front panel Pump Shutdown To shutdown the pump press the STOP push button on the controller front panel Maintenance The TwisTorr 84 AG Rack series controller does not require any maintenance Any work performed on the controller must be carried out by authorized personnel When a fault has occurred itis possible to use the Agilent repair service Replacement controllers are available on an advance exchange basis through Agilent WARNING Before carrying out any work on the controller disconnect it from the
4. A je inizia i 1 Van x nsa 99 v R1 R2 MASK TIME gt 00 00 00 00 SEC 00 00 00 KOO AM 99 99 99 v R1 R2 OUTPUT E k LOGIC _ L Flow 4 6 Figure 41 266 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Technical Information 17 R1 R2 TYPE selects the type of reference measurement to drive the relay Possible types Frequency driving frequency of the pump Power power supplied to the pump Time time from start Normal achievement of normal condition Pressure pressure read by the gauge if present R1 R2 SET VALUE Sets the reference value at which the relay R1 R2 is activated This parameter is not available if TIME or NORMAL previous parameter is selected as SETPOINT TYPE R1 R2 HISTERESYS Sets in percentage the hysteresis of the relay Ri R2 MASK TIME sets the masked time in hh mm ss measured from start within which the SETPOINT RI R2 is not driven even if the threshold value has been reached This parameter is not available if SETPOINT TYPE is set to NORMAL Ri R2 OUTPUT LOGIC Selects the control logic of the SETPOINT output positive logic the relay is energized when the measurement exceeds the reference negative logic the relay is energized when the measurement is below the reference This parameter is not available if SETPOINT TYPE
5. MAINS CABLE GAUGE CABLE 1 m GAUGE GAUGE EXTENTION CABLE 5 m Figure 4 TwisTorr 84 AG Rack Controller Connections 210 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Controller Specifications Technical Information 17 Tab 2 Input Voltage 100 240 Vac voltage fluctuation 10 Freguency 50 to 60 Hz Power 450 VA Fuse 2 x T4 A slow blow 250 V Output Voltage 75 Vac Freguency 1350 Hz Power 100 W Ramp 70 W Normal and Autotuning Environment storage 20 C to 70 C 0 95 Operating 5 45 C 0 90 Applied norr EN 61010 1 EN 55011 Class A EN 61000 3 2 EN 61000 3 3 EN 61000 6 2 EN 61000 4 2 3 4 5 6 11 8 Weight 1 7 Kg 3 2 Ibs Pollution Degree 2 Installation Category Acoustic noise 1507779 LpA c 70 dB A normal operation operator position The Controller must be positioned in such way that the mains cable can be easily disconnected TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 211 297 17 Technical Information Controller Outline The outline dimensions for the TwisTorr 84 Rack Controllers are shown in the following figure The TwisTorr controller can be used as a bench unit or as a rack module but it must be positioned so that free air can flow through the holes 9 4 0 37 106 4 4
6. The message will stay on until the temperature decreases below threshold value Press the STOP RESET pushbutton twice to start the pump If the controller transformer temperature exceeds 90 C the pump is shut off and the display will be as shown in the following figure CJO N T R O L L E R O V E R T E M P The message will stay on until the temperature decreases below threshold value Press the STOP RESET pushbutton twice to start the pump TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 289 297 17 Technical Information Indicates a fault in the circuit of the controller used to power the pump If the pump is stopped by an emergency stop signal provided via a remote contact the display will be as shown in the following figure O VIEJRI RII DIE Remove the controller power cable and check the emergency condition Then reconnect the power cable and press the START pushbutton to start the pump Controller power supply circuitry is faulty or the Controller received a spike Press the START push button twice to start the pump Should the message still be present call the Agilent service Check connections and shortages betwee
7. TOO HIGH LOAD Pendant le fonctionnement normal apr s la phase de mise en marche le courant absorb par la pompe est plus grand que celui qui a t programm S assurer que le rotor de la pompe a la possibilit de tourner librement Presser deux fois l interrupteur START pour remettre la pompe en marche SHORT CIRCUIT Pendant le fonctionnement normal apr s la phase de mise en marche la connexion de sortie est en court circuit V rifier les connexions entre la pompe et le contr leur Presser deux fois l interrupteur START pour remettre la pompe en marche SYSTEM OVERRIDE La pompe a t arr t e par un signal d alerte provenant d un contact loign D brancher le c ble d alimentation du contr leur et corriger la cause de l alerte Reconnecter le c ble d alimentation et presser deux fois l interrupteur START pour remettre la pompe en marche OVERVOLTAGE II s est produit une panne de la section d alimentation du contr leur ou bien le contr leur a recu un faux signal Presser deux fois l interrupteur START pour remettre la pompe en marche Si le message se pr sente nouveau s adresser Agilent pour l entretien POWER FAIL Panne dans la section d alimentation de la pompe du contr leur S adresser Agilent pour Maintenance 50 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A TwisTorr 84 FS AG Rack Controller Use
8. Amikor egy vez rl t le kell selejtezni megsemmis t sekor a t rgyk rbe tartoz nemzeti norm knak megfelel en kell elj rni TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 143 297 11 Felhaszn l i K zik nyv Megsemmis t s A c mk n jelenl v WEEE logo jelent se Az al bb l that szimb lum az EK WEEE elnevez s ir nyelv vel sszhangban ker l alkalmaz sra Ez a szimb lum mely csak az Eur pai K z ss g orsz gaiban rv nyes azt jelzi hogy a term k melyen megtal lhat NEM ker lhet k z ns ges h ztart si vagy ipari hullad kkal egy tt megsemmis t sre hanem azt egy szelekt v hullad kgy jt rendszerbe kell tov bb tani A v gfelhaszn l nak a gy jt si s megsemmis t si elj r s beind t sa c lj b l az ad sv teli szerz d s hat rid inek s felt teleinek alapos ttanulm nyoz sa ut n fel kell vennie a kapcsolatot a berendez s sz ll t j val legyen ez a gy rt vagy egy viszontelad 144 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Hiba zenetek Felhaszn l i K zik nyv 11 N h ny meghib sod si esetben a vez rl ndiagnosztikai ramk rei hiba zenetet jelen tenek meg l sd az al bbi t bl zatot Tab 1 ZENET LE R S JAV T SI TEV KENYS G CHECK CONNECTION TO PUMP sszek ttetesi hiba a szivatty s a vez rl k z tt vagy a szivatty h m rs klete 0 C al
9. N O R MA IL X X X X H z I X X X JA Vi X X X Where NORMAL indicates the operating regime of the pump XXXHz see description Pressing once Measures key I X XXA indicates the current absorbed by the pump V XXX V indicates the pump driving voltage Pressing 3 times the following is obtained P X X X W X X X X H z X X X JE Y Y m B ja X X Y Y m B ja r Z Z Z P lt X X X W X X X X H z TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 249 297 17 Technical Information 250 297 Where P XXXW indicates the current power supplied to the pump XXXHz see description Pressing once Measures key X XE YYmBar indicates the pressure currently measured by the gauge ZZZZ indicates the kind of gauge see table of gauge supported in the gauge chapter Other possible indications P X X X W X X X X H z G JA U G JE ER RIO R Where GAUGE ERROR gauge not connected or broken P IX X X W X X X X H z PIR JE S S JU R JE U N DJE R Where PRESS UNDER indicates that the pressure read is below the minimum measurement threshold set 5 E 9 mBar P IX X X W X X X X H
10. Figur 1 Styrenhetens f rpackning 102 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Bruksanvisning 8 Installation VARNING Styrenheten fungerar med en str mkabel som har tre ledare se tabellen som visar de delar som kan best llas och f r anv ndarens s kerhet ska den ha godk nd stickpropp enligt internationella standarder Anv nd alltid denna str mkabel och anslut stickproppen till ett v gguttag med fungerande jordanslutning f r att undvika elst tar och f r iakttagelse av CE specifikationer Sp nningen inuti styrenheten kan n h ga v rden och f rorsaka allvarliga skador och d dsfall Dra alltid ur str mkabeln fran v gguttaget innan n got installations eller underh llsmoment utf rs p styrenheten Styrenheten kan installeras p ett bord eller inuti ett d rtill avsett rack samtliga fall m ste dock kylluften kunna cirkulera fritt kring apparaten Installera och anv nd inte styrenheten i milj er som uts tts f r p verkan fr n atmosf ren regn sn is damm aggressiva gaser och inte heller i explosiv eller brandfarlig milj F ljande krav p omgivningsf rh llanden g ller vid drift temperatur fran 5 C till 45 C a relativ luftfuktighet 0 95 utan kondens Betr ffande vriga anslutningar och installation av tillbeh r h nvisas till avsnittet Technical Information TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 103
11. Bedrijfshandleiding 6 In geval van storingen wekt het zelfdiagnose circuit van de controller enkele foutmeldingen op die in de volgende tabel zijn omschreven Tab 1 BOODSCHAP OMSCHRIJVING REMEDIE CHECK CONNECTION TO PUMP Foutieve verbinding tussen pomp en controller Of De pomp heeft een lagere temperatuur dan 0 C Controleren of de verbindingskabel tussen pomp en controller aan beide uiteinden goed bevestigd is en geen onderbrekingen vertoond Bedien twee maal de START knop om de pomp Weer op te starten WAITING INTERLOCK Het interlock signaal op connector P1 is actief wegens onderbreking van de kortsluiting tussen pin 3 en pin 8 van connector J1 of wegens het openen van het externe interlock signaal Herstel de kortsluiting tussen pin 3 en pin 8 van connector P1 of sluit het externe interlock signaal PUMP OVERTEMP De temperatuur van het bovenste pomplager bedraagt meer dan 60 C Wacht tot de temperatuur weer onder de drempelwaarde is gezakt Bedien twee maal de START knop om de pomp weer op te starten CONTROLLER OVERTEMP De temperatuur van de controller bedraagt meer dan 70 C Of De temperatuur van de radiator van de controller bedraagt meer dan 60 C Wacht tot de temperatuur weer onder de drempelwaarde is gezakt Bedien twee maal de START knop om de pomp weer op te starten TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01
12. Entsorgung 36 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 5 297 Contents 6 297 Fehlermeldungen 37 Mode emploi 39 Indications generales 40 Emmagasinage 41 Preparation pour l installation 42 Installation 43 Utilisation 44 Procedures utilisation 47 Entretien 47 Mise au rebut 48 Messages d erreur 49 Manual de istrucciones 51 Informaci n general 52 Almacenamiento 53 Preparaci n para la instalaci n 54 Instalaci n 55 Uso 56 Procedimientos de uso 59 Mantenimiento 59 Eliminaci n 60 Mensajes de error 61 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Contents 5 Manual de Istru es 63 Informac es gerais 64 Armazenagem 65 Preparac o para a instalac o 66 Instalac o 67 Utilizac o 68 Procedimentos de uso 71 Manutenc o 71 Eliminac o 72 Mensagens de erro 73 6 Bedrijfshandleiding 75 Algemene informatie 76 Opslag 77 Voorbereiding voor installatie 78 Installatie 79 Gebruik 80 Gebruiksprocedures 83 Onderhoud 83 Afvalverwerking 84 Foutmeldingen 85 7 Istruktionsbog 87 Generel Information 88 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 7 297 Contents 8 297 Opbevaring 89 Forberedelser for installation 90 Installation 91 Anvendelse 92 Instruktion 95 Vedligeholdelse 95 Bortskaffelse 96 Fejlmeddelelser 97 Bruksanvisning 99 Allm n Information 100 F rvaring 101 F rberedelser f r installation 10
13. I al NI N SERIAL lt BAUD RATE lt 600 Bi 1200 i 4800 i 9600 SERIAL MODE RS232 RS485 SERIAL ADDRESS 4 00 Flow 6 6 Figure 43 BAUD RATE permits selection of the communication speed selecting this from 600 1200 4800 9600 baud SERIAL MODE permits setting of the type of interface to RS232 point to point or RS485 multidrop SERIAL ADDRESS sets the address of the node in the case of the RS485 interface This parameter is not visible if the R528382 is selected TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Technical Information 17 How to Use by Remote 1 0 ao A O N ma Power ON the controller Press the COUNTERS and MEASURES button toghether Select MODE REMOTE from the INPUT OUTPUT menu Exit from configuration menu Connection example How to Use in Serial Mode TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Power on the controller Connect the serial cable Select by front panel if you want to work in 232 or 485 and if necessary the serial address Select SERIAL from the INPUT OUTPUT menu Open the T software see orderable parts table Ready to operate by SERIAL connections 211 297 17 Technical Information Open Stop Open High Speed Controller Cloed Start
14. TwisTorr 84 FS AG O Figure 30 Start Stop and Reset Fail button Press once for the START command and again for the STOP command In the case of controller s failure press once to reset the fail condition The front panel START STOP function is available only if the controller is set to FRONT mode If it is set to REMOTE mode when the key is pressed an error message is shown indicating COMMAND LOCKED IN REMOTE if it is set to SERIAL mode the COMMAND LOCKED IN SERIAL MODE error message is displayed The Reset Fail function is always available regardless of controller mode Low Speed Press once to activate the LOW SPEED command press again to de activate The front panel LOW SPEED function is available only if the controller is set to FRONT otherwise an error message is returned If it is set to REMOTE mode the COMMAND LOCKED IN REMOTE error message is displayed while if itis in SERIAL mode the COMMAND LOCKED IN SERIAL MODE error message is returned TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 247 297 17 Technical Information Counters Pressing the first time on the display the following information is displayed Where CYCLE XXXX Number of start stop cycles TIME XXXXXm Time of last cycle minutes Pressing a second time the following is displayed P U M P L FJE X X X X X X h PUMP LIFE
15. TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A TwisTorr 84 FS AG Rack Controller User Manual 15 Priro nik za Navodila SploSne informacije 184 Skladi enje 185 Priprava za monta o 186 Monta a 187 Uporaba 188 Komande indikatorji in konektorji189 Opis prednje plo e 189 Postopki uporabe 191 Vklopitev Controllera 191 Zagon rpalke 191 Zaustavitev rpalke 191 Vzdr evanje 191 Odlaganje opadkov 192 Obvestilo o napaki 193 Prevod navodil v izvirniku SEE Agilent Technologies 183 297 15 Priro nik za Navodila Splo ne informacije 184 297 Naprava je namenjena samo za strokovno rabo Uporabnik mora temeljito prebrati priro nik in pri tem upo tevati vsako dodatno informacijo ki jo nudi Agilent Agilent ne odgovarja v slu aju celotnega ali delnega nespo tovanja navodil pri nepravilni uporabi nestrokovnega osebja v slu aju nedovoljenih posegov ali pri zanemarjenju specifi nih nacionalnih meril Controllerji serije TwisTorr 84 Rack so frekven ni pretvorniki na katere nadzor ima mikrokrmilnik Sestavljajo jih deli v solidnem stanju ki imajo zna ilnosti avtodiagnoze in avtoza ite Zna ilnosti controllerja Osprednja oddaljena serijska operativnost Upravljanje na 24 Vdc ventila ohlajevalne rpalke Upravljanje vent valve Branje hitrosti rpalke po ukazu zaustavitve branje zaustavitvene hitrosti a Branje pritiska Vmesnik Profibus opcijski Avtomati na post
16. A 85 297 6 Bedrijfshandleiding BOODSCHAP OMSCHRIJVING REMEDIE TOO HIGH LOAD De stroomopname van de pomp is groter dan de geprogrammeerde waarde Controleer of de pomprotor vrij kan draaien Bedien twee maal de START knop om de pomp weer op te starten SHORT CIRCUIT Tijdens normale werking na startfase is de uitgangsverbinding in kortsluiting Controleer de verbindingen tussen pomp en controller Bedien twee maal de START knop om de pomp weer op te starten SYSTEM OVERRIDE De pomp is stilgelegd door een noodsignaal afkomstig van een afstandscontact Koppel de voedingskabel van de controller af en elimineer de oorzaak van de noodstop Sluit de voedingskabel weer aan en bedien twee maal de START knop om de pomp weer op te starten OVERVOLTAGE Er is een storing opgetreden in de voedingssectie van de controller of de controller heeft een stoorsignaal ontvangen Bedien twee maal de START knop om de pomp weer op te starten Als de melding weer verschijnt zich voor onderhoud tot Agilent wenden POWER FAIL Defect in het voedingsgedeelte van de pomp van de controller Neem contact op met Agilent voor onderhoud 86 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A TwisTorr 84 FS AG Rack Controller User Manual 7 Istruktionsbog Generel Information 88 Opbevaring 89 Forberedelser for installation 90 Installation 91 Anvendelse 92 I
17. Itis possible to enter a sub branch by pressing the INCREASE button If no buttons are pressed for more than 1 minute the controller automatically quits the programming environment canceling any modifications made to the current parameter The figure below shows the first level of the configuration menu and the links to the respective second level menus indicated below TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 259 297 17 Technical Information MODE lt gt FRONT A Y REMOTE SERIAL y K E PROFIBUS PUMP SETTING lt gt HIGH SPEEDADJ x T EEE EZ i i ST I Y ae I INPUT OUTPUT lt gt STARTMODE A A Fosa i T Fe pa Le Y kon 1 SETPOINT i RI SETTING lt x gt RURZTRESHOLD I i A I 1 VE Y 1 k SETPOINT R2 SETTING SSS 5 L I PRESSURE UNIT GAUGE lt gt I Es m Zu i are Abt I i I SERIAL i BAUD RATE l i Re 27 Ez uo aos K Flow 1 6 Figure 38 Mode Menu MODE permits selection see Flow 1 6 of the operating mode of the controller from those indicated below 260 297 FRONT accepts commands from the front panel REMOTE accepts commands from the remote input connector SERIAL accepts commands from the serial interface or
18. and press the START push button twice to start the pump OVERVOLTAGE Controller power supply circuitry is faulty or the Controller received a spike Press the START push button twice to start the pump Should the message still be present call the Agilent service POWER FAIL Failure in the controller s pump power supply section Contact Agilent for Maintenance TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A TwisTorr 84 FS AG Rack Controller User Manual 09 0 0 17 0 Technical Information o amp e hi id TwisTorr 84 Rack Controller Description 209 Controller Specifications 211 Controller Outline 212 Controller Connection 213 J6 Fan 213 J7 Vent 214 P1 Input 215 Output 216 R2 Output Diagrams 220 Programmable Analog Output Diagrams 222 Pump Connector 223 J5 Gauge Connector 223 Stop Speed Reading and Active Stop 226 J2 Serial Connector 227 Connector Examples 228 Serial Communication Descriptions 229 Letter Protocol Description 230 Window Protocol 236 Description 236 Communication Protocol 236 Examples 239 Window Meanings 242 How to Use by Front Panel 247 Use 252 General 252 2 253 a gt Agilent Technologies 207 297 17 Technical Information Programming 258 Configuration Menu 258 Mode Menu 260 Pump Setting Menu 261 Input Output Menu 263 Setpoint R1 and Setpoint R2 Submenus 266 Gauge Menu 268 Serial Menu 270 How
19. bedienen Onderhoud De controllers van de serie TwisTorr 84 zijn onderhoudsvrij Eventuele werkzaamheden moeten door bevoegd personeel worden uitgevoerd In geval van storing is het mogelijk om de reparatiedienst van Agilent of de Agilent advanced exchange service in te schakelen zo krijgt men een ruilcontroller ter vervanging van de defecte controller M RE EI MN Alvorens werkzaamheden aan de controller uit te voeren de voedingskabel afkoppelen Mocht de controller gesloopt worden ga dan overeenkomstig de specifieke nationale wetgeving te werk TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 83 297 6 Bedrijfshandleiding Afvalverwerking 84 297 Betekenis van het logo WEEE op de etiketten Het onderstaande symbool wordt aangebracht in overeenstemming met de EG richtlijn WEEE Dit symbool alleen geldig voor de landen van de Europese Gemeenschap geeft aan dat het product waarop het is aangebracht NIET mag worden afgevoerd samen met mormaal huisvuil of industrieel afval maar gescheiden moet worden ingezameld De eindgebruiker wordt dus verzocht contact op te nemen met de leverancier van het apparaat zij het de fabrikant of een wederverkoper om het proces van gescheiden inzameling en verwerking in gang te zetten na de van toepassing zijnde termen en voorwaarden van het verkoopcontract te hebben gecontroleerd TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Foutmeldingen
20. ch specifick ch st tn ch norem TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 167 297 13 N vod k Pou it Likvidace V znam loga WEEE nach zejiciho se na t tku N e uveden symbol odpov d sm rnicim CE pojmenovan m WEEE Tento symbol platn jen pro st ty Evropsk Unie ur uje e v robek kter je takto ozna en NESM b t likvidov n spole n s ostatn mi dom c mi nebo pr myslov mi odpady ale je nutno ho p edat do pat i n ch provozn ch sb ren kde mus b t tr d n a likvidov n odd len od m stsk ho odpadu U ivateli kter m n v robek likvidovat doporu ujeme aby se nakontaktoval primo s v robcem nebo prodejcem kter se po pat i n m prov en term n a smluvn ch podm nek postar o kompletn likvidaci uveden ho v robku 168 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Chybn zpr vy N vod k Pou it 13 V n kter ch p padn ch poruch ch na autodiagnostick ch obvodech kontrol r p ed v n kolik chybn ch odkaz kter jsou vyjmenov ny v tabulce kter se nach z na n sleduj c str nce Tab 1 ZPR VY POPIS KOREKCE CHECK CONNECTION TO PUMP Chybn fungov n spojen mezi erpadlem a konrol rem P31 Nebo erpadlo m ni teplotu ne je 0 C Prov it zda kabelov spojen mezi pumpou a kontrol rem je spr vn upevn n na obou dvou konc ch a e
21. features Controller features a Front Remote Serial Operation 24Vde pump fan cooling drive Vent valve drive Pump speed reading after stop command stop speed reading a Pressure reading a Input voltage auto setting Profibus interface optional The following paragraphs contain all the information necessary to guarantee the safety of the operator when using the equipment Detailed information is supplied in the appendix Technical Information TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Instructions for Use 16 This manual uses the following standard protocol WARNING The warning messages are for attracting the attention of the operator to a particular procedure or practice which if not followed correctly could lead to serious injury CAUTION The caution messages are displayed before procedures which if not followed could cause damage to the equipment The notes contain important information taken from the text Storage When transporting and storing the controllers the following environmental requirements should be satisfied a temperature from 20 C to 70 C a relative humidity 0 95 without condensation TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 197 297 16 Instructions for Use Preparation for Installation The controller is supplied in a special protective packing If this shows signs of damage which may hav
22. fils voir tableau des pi ces que l on peut commander avec une fiche du type approuv au niveau international en vue de la s curit de l usager Utiliser toujours ce cable d alimentation et introduire la fiche dans une prise pourvue d un branchement au sol appropri la masse afin d viter toute d charge lectrique et de respecter les sp cifications CE A l int rieur du contr leur se d veloppent de hautes tensions qui peuvent causer de graves dommages voire la mort Avant d effectuer toute op ration d installation ou d entretien du contr leur le d brancher de la prise d alimentation Le contr leur peut tre install sur une table ou l int rieur d un rack pr vu cet effet II est en tout cas n cessaire que l air de refroidissement puisse circuler librement l int rieur de l appareil Ne pas installer et ou utiliser le contr leur dans des milieux expos s des agents atmosph riques pluie gel neige des poussi res des gaz de combat ainsi que dans des milieux explosifs ou risque lev d incendie Pendant le fonctionnement il est n cessaire de respecter les conditions environnementales suivantes temp rature de 5 C 45 C a humidit relative de 0 a 95 non condensante Pour les autres connexions et pour installation des accessoires en option voir la section Technical Information TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 43 297 3 Mode d empl
23. itiu a jeho al ie doplnky dodan podnikom Agilent Podnik Agilent nepreber na seba iadnu zodpovednos za pln alebo iasto n nedodr iavanie n vodu za nespr vne pou vanie pr stroja nekompetentn mi osobami za nepovolen z sahy a za pou vanie ktor nie je v zhode s pr slu n mi n rodn mi normami Controllers s rie TwisTorr 84 Rack s meni i kmito tu kontrolovan mikroprocesorom vyroben prvkami pevnej f zy a so schopnos opu samodiagnostiky a samokontroly Charakteristiky controller a eln dialkov s riov riadenie 24 Vdc riadenie chladiacej lopatky erpadla Riadenie vent valve tanie r chlosti erpadla po poveli zastavenia tanie r chlosti zastavenia tanie tlaku Medzi lanok Profibus na objedn vku Automatick nastavenie vstupn ho nap tia alej s pop san v etky potrebn inform cie ktor ch lohou je zabezpe i bezpe nos pracovn ka po as pou vania pr stroja Podrobn inform cie s uveden v dodatku Technical Information 172 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A N vod na Obsluhu 14 Tento n vod pou va nasleduj ce sign ly M7 10138 Sign l nebezpe ie upozor uje pracovn ka na ur it pracovn postup ktor ke nie je preveden spr vne m e zapr ini v ne osobn poranenia POZOR Sign ly pozor s pred t mi postupmi ktor v pr pa
24. kaj c se spojen nebo dal ch op n ch detajl je t eba se obracet na odstavec Use v p loze Technical Information Ve ker elektrick a pneumatick spojen se mus vykonat p ed pou it m kontrol ru p i em je t eba se obracet na p slu nou p ru ku napojen ho erpadla NEBEZPE Aby se vyhnulo nebezpe kter m e ohrozit osoby i p stroj mus se zkontrolovat jeho stabilita v p pad e erpadlo je polo en na stole Jestli e vstupn p ruba nen napojen na syst m nebo nen uzav en se zav raj c p rubou erpadlo se nesm spustit do provozu 164 297 Uzav raj c konektor J1 jestli e nebude uskute n no dn vn j spojen mus z stat propojen se sv m m stkem erpadla pre pr zdna a TwisTorr se mohou zapnout sou asn TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A N vod k Pou it 13 Ovl d ni indik tory a konektory V n sledujicim je uk z n eln a zadn panel kontrol ru Pro ir detajly je tfeba se obr tit na sekci Technical Information Popis eln ho panelu 1 3 2 4 Postava 2 eln panel Konrol ru TwisTorr 84 AG 1 Tla tko p ivolan ch parametr na displeji cycle number cycle time a pump life 2 Tla tko na volbu zp sobem LOW SPEED Je aktivni jen pii zvolen m zp sobu o
25. lt DATA gt lt ETX gt lt CRC gt Where When a data is indicated between two quotes it means that the indicated data is the corresponding ASCII character 236 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Technical Information 17 lt STX gt Start of transmission 0x02 lt ADDR gt Unit address 0x80 for RS 232 lt ADDR gt Unit address 0x80 device number 0 to 31 for RS 485 lt WIN gt Window a string of 3 numeric character indicating the window number from 000 to 999 for the meaning of each window see the relevant paragraph lt COM gt Command 0x30 to read the window 0x31 to write into the window lt DATA gt an alphanumeric ASCII string with the data to be written into the window In case of a reading command this field is not present The field length is variable according to the data type as per the following table Tab 13 Data Type Field Length Valid Characters Logic L 1 OFF ON Numeric N 6 LEE JO Y right justified with Alphanumeric A 10 from blank to ASCII lt ETX gt End of transmission 0x03 lt CRC gt XOR of all characters subseguent to lt STX gt and including the lt ETX gt terminator The value is hexadecimal coded and indicated by two ASCII character The addressed SLAVE will respond with an ANSWER whose structure depends from the MESSAGE type When the MESSAGE is a readin
26. nyv t VESZ LY Abban az esetben ha a szivatty egy asztalon ker lt elhelyez sre a szem lyekben s a berendez sben val k rok elker l se rdek ben biztos tani kell az asztal stabilit s t Soha nem szabad a szivatty t a bementi peremnek a rendszerhez val csatlakoztat sa vagy a z r peremmel val lez r sa n lk l zemeltetni A J1 lez r csatlakoz ssze kell maradjon k tve a megfelel tk t ssel jumper ha nincs semmif le k ls sszek ttet s Az el v kuum s a TwisTorr szivatty egyidej leg is be lehetnek kapcsolva 140 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Felhaszn l i K zik nyv 11 A vez rl parancsai kijelz i s csatlakoz i Az al bbiakban bemutat sra ker l a vez rl el s h tlapja Tov bbi r szletek tal lhat k a Technical Information c m szakaszban Az el lap le r sa 5 1 3 2 4 bra 2 A TwisTorr 84 AG sz m vez rl el lapja 1 Nyom gomb a param tereknek ciklussz m ciklusid szivatty lettartama a kijelz re val leh v s ra 2 A LOW SPEED kis sebess g zemm d kiv laszt s ra szolg l nyom gomb Csak akkor akt v amikor az el lapr l a parancsm d ki lett v lasztva Egyszer megnyomva a szivatty stand by sebess ggel forog M g egyszer megnyomva a LOW SPEED m
27. t v delmi k pess gekkel A vez rl tulajdons gai a El lapr l t rt n t v soros vonalon kereszt li m k dtet s a A szivatty h t ventill tor nak 24 Vdc fesz lts gen t rt n vez rl se a Avent valve vez rl se a A szivatty sebess g nek leolvas sa a le llit si parancsot k vet en le ll si sebess g leolvas sa A nyom s rt k leolvas sa Profibus illeszt opcion lis A bemeneti fesz lts g automatikus be ll t sa Az elk vetkez szakaszok tartalmazz k mindazokat az ismereteket melyek a kezel biztons g t hivatottak garant lni a berendez s haszn lata sor n R szletes inform ci k tal lhat k a Technical Information c m mell kletben 136 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Felhaszn l i K zik nyv 11 E k zik nyv az al bbi megegyez sszer jel l seket alkalmazza VESZ LY A vesz lyt jelz zenetek olyan elj r sra vagy specifikus tev kenys gre h vj k fel a kezel figyelm t melyek ha nem megfelel m don ker lnek v grehajt sra s lyos szem lyi s r l seket okozhatnak 3197383116 A figyelmeztet zenetek azon elj r sok el tt ker lnek megjelen t sre melyek figyelmen k v l hagy sa a berendez s k rosod s hoz vezethet A megjegyz sek fontos a sz vegb l kivonatolt inform ci kat tartalmaznak T rol s A vez rl k sz ll t sa s t rol sa sor n az al
28. zpr vy 169 14 N vod na Obsluhu 171 V eobecn inform cie 172 Usklad ovanie 173 Pr prava pre in tal ciu 174 In tal cia 175 Pou itie 176 Postup pri pou it 179 dr ba 179 Likvid cia 180 Oznamy v d 181 15 Priro nik za Navodila 183 Splo ne informacije 184 Skladi enje185 Priprava za monta o 186 Monta a 187 Uporaba 188 Postopki uporabe 191 Vzdr evanje 191 Odlaganje opadkov 192 Obvestilo o napaki 193 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 11 297 Contents 12 297 16 Instructions for Use 195 General Information 196 Storage 197 Preparation for Installation 198 Installation 199 Use 200 Use Procedure 203 Maintenance 203 Disposal 204 Error Messages 205 17 Technical Information 207 TwisTorr 84 Rack Controller Description 209 Controller Specifications 211 Controller Outline 212 Controller Connection 213 R1 R2 Output Diagrams 220 Programmable Analog Output Diagrams 222 J2 Serial Connector 227 Letter Protocol Description 230 Examples 239 How to Use by Front Panel 247 Use 252 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Contents Programming 258 How to Use by Remote 1 0 271 How to Use in Serial Mode 271 Profibus Option 273 Error Messages 288 Orderable Parts 291 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 13 297 Contents 14 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901
29. 01 A Technical Information 17 Examples Command START Source PC Destination Controller 02 80 30 30 30 31 31 03 42 33 STX ADDR WINDOW WR ON ETX CRC Source Controller Destination PC m ja m 8 STX ADDR ACK ETX CRC Command STOP Source PC Destination Controller 02 80 30 30 30 31 30 103 42 32 STX ADDR WINDOW WR OFF ETX CRC Source Controller Destination PC 02 80 06 03 38 35 STX ADDR ACK ETX CRC TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 239 297 17 Technical Information Command SOFT START ON Source PC Destination Controller 02 80 31 30 30 31 31 03 42 32 STX ADDR WINDOW WR ON ETX CRC Source Controller Destination PC 02 80 06 03 38 35 STX ADDR ACK ETX CRC Command SOFT START OFF Source PC Destination Controller 02 80 31 30 30 31 30 03 42 33 STX ADDR WINDOW WR OFF ETX CRC Source Controller Destination PC 02 80 06 03 38 35 STX ADDR ACK ETX CRC 240 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Technical Information 17 Command READ PUMP STATUS Source PC Destination Contro
30. 01 A 191 297 15 Priro nik za Navodila Odlaganje opadkov 192 297 Pomen znamke WEEE na etiketah Spodaj navedeni simbol je v skladu z direktivo ES znano pod imenom WEEE Ta simbol ki velja samo v dr avah Evropske Skupnosti pomeni da izdelek NE SMETE ODSTRANITI skupaj z ostalimi komunalnimi ali pa industrijskimi odpadki temve morate poskrbeti za njihovo primerno locevanje Zato pozivamo uporabnike da se ali pri prodajalnem centru ali pa pri prodajalcu seznani o postopku lo evanja in odstranitve odpadkov ele nato ko se je seznanil s pogoji in z merili kupopordajne pogodbe TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Obvestilo o napaki Priro nik za Navodila 15 V nekaterih slu ajih kvara poka e elektri no vezje avtodiagnoze controller a nekaj obvestil o napakah kot so opisane v spodnji tabeli Tab 1 OBVESTILO OPIS POPRAVA CHECK CONNECTION TO PUMP Napaka v priklju itvi rpalke in controller a Ali rpalka ima ni jo temperaturo od 0 C Preverite da je priklju ni kabel med rpalko in controller em na obeh koncih trdno pritrjen in da ni prekinjen Dvakrat pritisnite tipko START za ponoven zagon rpalke WAITING INTERLOCK Signal interlocka prisoten na konektorju P1 zaradi prekinitve kratkega stika med pinom 3 in pinom 8 konektorja J1 ali ker se je odprl signal zunanjega interlocka Ponovno nastavite kratki stik med pinom 3 in pinom 8 konektor
31. 17 Internal link state machine Status POWER ON Interface set up SRC ADDR Search for the controller serial address IDENTIFY Identify controller model and protocol DATA EX Regular data exchange The two machines continuously share 1 0 data with the relative bus and interact each other only in following conditions a ProfiBus Data Exchange is suspended static diagnosis activated if the internal serial link in not established TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 215 297 17 Technical Information a Internal serial link Data Exchange is suspended only for output data if the ProfiBus State machine is not in Data Exchange mode As a general rule unrecoverable communication errors make each machine to jump to the state immediately following the power on state WAIT_PRM or SRC_ADDR Message Mapping The communication is based on the continuous data exchange capability of the ProfiBus standard where the master sends continuously the entire slave configuration and reads back the entire slave status For this purpose one Input from slave to master and one Output from master to slave buffers are provided All the needed parameters are mapped inside each buffer The following tables summarise the ProfiBus parameter access related to the corresponding windows serial protocol for this protocol please refers to the serial interface paragraph The interface doesn t
32. 19 9141360 E a sa TwisTorrs FsaG 244 0 9 61 SE 96 1 3 78 Dimensions mm inches Figure 5 Controller outline 212 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Technical Information 17 Controller Connection J6 Fan The 24 Vdc 150 mA maximum output voltage is present after START pushbutton is pressed and will remain present until a fault condition is displayed on front panel display or the turbopump is stopped This is a dedicated output for the optional TwisTorr 84 pump cooling fan see orderable parts table If you already have fan installed use the available adapter cable to connect to the pump J6 FAN PURGE COMMON COMMON PURGE FAN 24VDC 24VDC I MAX 100mA I MAX 150mA PURGE FAN Figure 6 Fan Connector TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 213 297 17 Technical Information J7 Vent J7 VENT COMMON ENABLE N C VALVE ENABLE N O VALVE 24VDC MAX 60mA Figure 7 Vent Connector This is dedicated 24 Vdc connector to control the optional vent valve see orderable parts table The vent valve can be driven by controller automatically or by serial line If you already have a vent valve installed 110 Vac powered this valve must be replace
33. 5v 2 pins before Imax 60mA measuring voltage Pin 5 negative Pin 12 positive 11 4 R1 Programmable Set Point Out Optically isolated Connect a 10kohm can be related to Frequency Vmax open 24v resistor between the Power Time Status or Vlow max 1 5v 2 pins before Pressure See following Imax 60mA measuring voltage figures for more details All Pin 5 negative the setting can be done by Pin 12 positive front panel or serial line win 101 to 105 and 162 14 7 R2 Programmable Set Point Out Optically isolated Connect a 10kohm Can be related to Frequency Vmax open 24v resistor between the Power Time Status or Vlow max 1 5v 2 pins before Pressure See following Imax 60mA measuring voltage figures for more details All Pin 7 negative the setting can be done by Pin 14 positive front panel or serial line win 171 to 176 218 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Technical Information 17 Pins Name Description Electrical Note 2 1 Programmable Programmable analog output Optically isolated Connect a 100kohm Analog Output Can be related to frequency Rload min 10kohm resistor between the power pump temperature Ripple Vpp max 2 pins before linear or pressure read by 200mV measuring voltage the external gauge Precision 5 The setting can be done by Resolution 40mV front panel or serial line Pin 1negative win 111 Pin 2 positive OV 0Hz 0W 0 C 10V 1350Hz 70W 100
34. 64391318 Toll free 800 820 3278 vacuum cnmarketing agilent com vpc customerservice agilent com France Agilent Technologies Parc Technopolis Z A de Courtaboeuf 3 avenue du Canada CS 90263 91978 Les Ulis cedex France Tel 33 0 1 64 53 61 15 Fax 33 0 1 64 53 50 01 vpf sales agilent com Germany and Austria Agilent Technologies Sales amp Services GmbH amp Co KG Lyoner Str 20 60 528 Frankfurt am Main GERMANY Tel 49 69 6773 43 2230 Fax 49 69 6773 43 2250 Agilent Vacuum Products Division Sales and Service Offices India Agilent Technologies India Pvt Ltd Unit Nos 105 116 First Floor Splendor Forum Plot No 3 District Centre Jasola New Delhi 110025 Ph 91 11 4623 7100 Fax 91 4623 7105 Toll Free 18001801517 Italy Agilent Technologies Italia S p A Via F Ili Varian 54 10040 Leini Torino Italy Tel 39 011 9979 111 Fax 39 011 9979 350 Toll free 00 800 234 234 00 vpt customerservice agilent com Japan Agilent Technologies Japan Ltd 8th Floor Sumitomo Shibaura Building 4 16 36 Shibaura Minato ku Tokyo 108 0023 Japan Tel 81 3 5232 1253 Fax 81 3 5232 1710 Toll Free 0120 655 040 vpj customerserviceQagilent com Korea Agilent Technologies Korea Ltd Shinsa 2nd Bldg 2F 966 5 Daechi dong Kangnam gu Seoul Korea 135 280 Tel 82 0 2 2194 9449 Fax 82 0 2 3452 3947 Toll free 080 222 2452 vpk customerserviceQagilent com Mexico Agilent T
35. Cloed Low Speed 4 Start Stop N 2 Closed Stop 3 Interlock yh Open Allow Start 4 System Override Imput Soft Start Connector 5 6 7 8 9 S Open Normal Start Cloed Soft Start Output Connector 4K7 M Fault 24 VDC 15 K LA OFF OK ON Fail Fault 8 4K7 M Start 24 VDC 13 gt OFF z Stop Normal Operation ON Ramp Start 6 4K7 M Low Speed 24 VDC 12 DA L OFF High speed Low Speed 5 ON Low speed setted 4K7 NA R2 R1 24 VDC 14 11 DAJ LA OFF Pump under speed threshold ON Pump over speed threshold R2 R1 7 4 Pump Power 2 Monitor 10V 150W Monitor Com 1 A V Speed value v Power value Pump Frequency Monitor 10V 81 KRPM 9 Figure 44 272 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Technical Information 17 Profibus Option General The ProfiBus option allow to communicate with the controller as ProfiBus DP slave device The option works as a bi directional bridge between the ProfiBus network and the Agilent turbo controller internal link The interface provides input data measures and output data commands to the controller and in addiction provides standard and user related diagnostics in order to allow the user to manage the exceptions Installation This option is factory installed The ProfiBus connector pin out is reported in the following figure Please in order to obtain best performance use ProfiBus certified
36. Istruktionsbog 7 I brugsanvisningen anvendes f lgende standard rubrikker OKB Advarselsmeddelelserne informerer operat ren om at en speciel procedure eller en vis type arbejde skal udf res pr cist efter anvisningerne I modsat fald er der risiko for sv re personskader dile ple Denne advarselsmeddelelse vises f r procedurer der skal f lges n je for ikke at risikere maskinskader Dette g r opm rksom p vigtig information i teksten Opbevaring F lgende krav til omgivelsesforholdene g lder ved transport og opbevaring af styreenheden temperatur fra 20 C til 70 C a relativ luftfugtighed 0 95 2 ikke kondenserende TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 89 297 7 Istruktionsbog Forberedelser for installation 90 297 Styreenheden leveres i en speciel beskyttende emballage Kontakt den lokale forhandler hvis emballagen viser tegn p skader der kan v re opst et under transporten S rg for at styreenheden ikke tabes eller uds ttes for stad ved udpakningen Smid ikke emballagen ud Materialet kan genbruges 100 og opfylder EU direktiv 85 399 om milj beskyttelse EU l 5 i Figur 1 Styreenhedens emballage TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Istruktionsbog 7 Installation For at sikre brugersikkerhed skal styreenheden tilkobles et stramkabel med tre ledere se reservedelslisten og god
37. Point Mask sec 174 R W L R2 Set Point Signal Activation Type 0 high level active 1 low level active 175 R W N R2 Set Point hysteresis in of R2 Valve 176 R A R2 Set Point Pressure Threshold Valid if win 171 4 Format X X EsXX Where X 0 to 9 S 0r 177 R W L Start Output Mode 0 Starting Output ON only with pump Status Starting 1 running Output ON when the pump is running default 244 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Technical Information 17 181 R W N Gas type 0 not configured 1 Nitrogen 2 Argon 3 Idrogen 4 other 182 R W N Gas correction 200 R N Pump current in mA dc 201 R N Pump voltage in Vdc 202 R N Pump power in W pump current x pump voltage duty cycle 203 R N Driving freguency in Hz 204 R N Pump temperature in C 0 to 70 205 R N Pump status Stop 0 Waiting intik 1 Starting 2 Auto tuning 3 Braking 4 Normal 5 Fail 6 206 R N Error code Bit description see the following figure 211 R N Controller Heatsink Temperature C 216 R N Controller Air Temperature C 224 R A Pressure reading Format X X E XX 226 R N Rotation Frequency rpm 257 R N Gauge status 0 No gauge connected 1 gauge connected 2 Under range gauge error 3 over range gauge error 4 Rid unknown 267 R W N Gauge power 0 gauge off 1 gauge On 2 programmable power spl 3 programmable power sp2 4
38. Profibus interface if present PROFIBUS this operating mode is present only if the Profibus interface is installed on the controller TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Technical Information 17 Pump Setting Menu EU eta x le v HIGH SPEED ADJ Hz lt 0000 LOW SPEED ADJ DE E EES Hz lt gt 0000 x 4 RAL FORTE 9999 me en i i i i i SOFT START 4 gt YES i na wens A E y H Only Front Mode H 9999 E Configuration NO IE gr EXTERNAL FAN CNF lt ALWAYS ON A OFF LIMPOWER SERIAL Y VENT VALVE MODE AUTO TIME A k MANUAL v AUTO PUMP SPEED VENT VALVE DELAY lt gt 0000 VENT OPEN TIME 0000 losusssisssssa OSNO LIMIT gt i sena H Teer 9999 I LOAD GAS TYPE le Argon liuczsagassasat x E t 9999 Air WATER COOLING gt YES A E No v ACTIVE STOP ves 7 y NO Y STOP SPEED le gt READING E No Flow 2 6 Figure 39 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 261 297 17 Technical Information 262 297 This menu contains all the parameters that have a direct effect on driving of the pump HIGH SPEED Sets in Hz the s
39. R2 captions The meaning of these rectangles is as follows LS the controller is at LOW SPEED AG the Gauge is connected to the controller R1 relay set point RI is active R2 relay set point R2 is active em LETT mir AG R2 Figure 31 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 251 297 17 Technical Information Use General Make all vacuum manifold and electrical connections and refer to TwisTorr pump instruction manual before to operating the TwisTorr controller WARNING To avoid injury to personnel and damage to the equipment if the pump is laying on a table make sure it is steady Never operate the TwisTorr pump if the pump inlet is not connected to the system or blanked off The input signal P1 connector should be left in position including the shipping links if no external connections are made The forepump and the TwisTorr pump can be switched on at the same time 252 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Startup Technical Information Plug the controller power cable into a suitable power source The display lights up for approx 2 seconds and shows 17 A U T 0 T EIS T K After 2 seconds the display shows the following screen page
40. XXXXXX total operating time hours of the pump Pressing a third time the following message Is displayed MIN X X X X X X X X IX SIN Y LY LY LY LY LY LY LY LY LY MN Model Number of the controller SN Serial Number On pressing the key again the main screen page is redisplayed Measures Pressing once the following is obtained P X X X W X XIX X Hz T XIX 9 IC Where P XXX W is the current power supplied to the pump 248 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Technical Information 17 T XX C is the current temperature of the pump XXXX Hz is the current freguency of rotation of the pump This value is set by default to 963 Hz but can be modified by the user according to needs proceeding as described in the PROGRAMMING paragraph The unit of measurement HZ Krpm default Hz is selected by the user from the INPUT OUTPUT gt SPED menu If the SOFT START function PUMP SETTING menu SOFTSTART is active and the pump is ramping indication of the speed of rotation is replaced with a bar graph that indicates the soft start step in course and the total number of steps to be performed On completion of the soft start ramp the bar graph is replaced with indication of the frequency of rotation of the pump Pressing twice the following is obtained
41. any scaling operation on the read written parameters It acts only as a gateway between the ProfiBus network and the pump s controller serial interface As a consequence of this the scale and the meaning of some parameters depends directly to the specific model of Turbo Pump controller connected to the interface 276 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Parameter Buffer Tab 18 Parameter buffer Technical Information 17 OFFSET SIZE BYTE BYTE UNIT RES RANGE DESCRIPTION WIN SERIAL 0 1 0 99 Gauge gas load type The value is divided by 10 entering 12 the controller will apply 1 2 Enter here the correction factor for gas necessary only if gauge is connected 161 1 2 mA Hz sec 0 10000 Setpoint 1 value Enter here the threshold value for the R1 output valid only if Bo B2 of Parameter Buffer Offset 21 is equal to 0 1 2 or 3 102 3 2 Sec 0 30000 Setpoint 1 Mask Time Set here the time measured from the start pump event while the R1 output is masked not activated 103 5 2 mA Hz sec 0 10000 Setpoint 2 value Enter here the threshold value for the R2 output valid only if B3 Bs of Parameter Buffer Offset 21 is equal to 0 1 2 or 3 172 7 2 Sec 0 30000 Setpoint 2 Mask Time Set here the time measured from the start pump event while the R2 output is masked not activated 173 9 2 0 2sec bit 0 30000 Vent Valve Openi
42. bbi k rnyezeti felt teleket kell biztos tani h m rs klet 20 C s 70 C k z tt relativ nedvess gtartalom 0 95 nem lecsap d TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 137 297 11 Felhaszn l i K zik nyv A telepit sre val el k szit s A vez rl speci lis v d csomagol sban ker l lesz ll t sra ha ez k rosod s jeleit mutatja melyek a sz llit s sor n keletkezhettek kapcsolatba kell l pni a helyi forgalmaz irod val A kicsomagol s sor n k l nleges figyelmet kell ford tani arra hogy a vez rl le ne ess k s ne szenvedjen t d seket A csomagol anyagot nem szabad sz tsz rni a k rnyezetben Az anyag teljes m rt kben jrafelhaszn lhat s megfelel a k rnyezetv delemmel kapcsolatos EGK 85 399 es ir nyelvnek bra 1 sz m vez rl k csomagol sa 138 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Felhaszn l i K zik nyv 11 Telep t s A vez rl nemzetk zileg j v hagyott csatlakoz dug val ell tott h romer h l zati k bellel kell hogy t pl lva legyen a rendelhet alkatr szeket l sd a t bl zatban Mindig ezt a h l zati k belt kell haszn lni s a csatlakoz dug t megfelel f ldcsatlakoz wal ell tott aljzatba illeszteni az elektromos kis l sek elker l se s az EK el r sainak a tiszteletben tart sa rdek ben A vez rl belsej ben nagyfesz lts ge
43. com PACIFIC RIM please visit our website for individual office information http www agilent com chem vacuum Worldwide Web Site Catalog and Order On line www agilent com chem vacuum Representatives in most countries 12 13
44. con la oficina de venta m s cercana Durante la operaci n de desembalaje prestar una atenci n especial a no dejar caer el controler y evitarle golpes No dispersar el embalaje en el medio ambiente El material es totalmente reciclable y cumple con la directiva CEE 85 399 para la preservaci n del medio ambiente Figura 1 Embalaje de los Controlers 54 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Manual de istrucciones 4 Instalaci n El controler debe ser alimentado mediante un cable de tres hilos ver tabla de los componentes que pueden ser ordenados con una clavija del tipo aprobado a nivel internacional con la finalidad de respetar las normas correspondientes a la seguridad del usuario Utilizar siempre este cable de alimentaci n e introducir la clavija en un enchufe con una conexi n de masa adecuada para evitar descargas el ctricas y respetar las especificaciones CE Dentro del controler se desarrollan altas tensiones que pueden causar graves da os o la muerte Antes de efectuar cualquier operaci n de instalaci n o mantenimiento del controler desconectarlo del enchufe de alimentaci n El controler puede instalarse en una mesa o dentro de un rack espec fico En cualquier caso es necesario que el aire de refrigeraci n pueda circular libremente alrededor del aparato No instalar y o utilizar el controler en ambientes expuestos a agentes atmosf ricos lluvia hielo y nieve po
45. di arresto lettura velocit di arresto Lettura della pressione Interfaccia Profibus opzionale Impostazione automatica tensione di ingresso Nei paragrafi seguenti sono riportate tutte le informazioni necessarie a garantire la sicurezza dell operatore durante l utilizzo dell apparecchiatura Informazioni dettagliate sono fornite nell appendice Technical Information TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Istruzioni per uso 1 Guesto manuale utilizza le seguenti convenzioni WAVES LIN AV I messaggi di avvertenza attirano l attenzione dell operatore su una procedura o una pratica specifica che se non eseguita in modo corretto potrebbe provocare gravi lesioni personali mai dla 3 messaggi di attenzione sono visualizzati prima di procedure che se non osservate potrebbero causare danni al apparecchiatura Le note contengono informazioni importanti estrapolate dal testo Immagazzinamento Durante il trasporto e l immagazzinamento dei controller devono essere soddisfatte le seguenti condizioni ambientali a temperatura da 20 C a 70 C umidit relativa 0 95 non condensante TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 17 297 1 Istruzioni per uso Preparazione per l installazione Il controller viene fornito in un imballo protettivo speciale se si presentano segni di danni che potrebbero essersi verificati durante il trasp
46. dispositivo tanto si ste es la casa fabricante o un distribuidor para poder proveer a la recogida y eliminaci n del producto despu s de haber efectuado una verificaci n de los t rminos y condiciones contractuales de venta TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Mensajes de error Manual de istrucciones 4 En algunos casos de aver a los circuitos de autodiagnosis del controler presenta algunos mensajes de error detallados en la tabla siguiente Tab 1 MENSAJE DESCRIPCI N ACCI N CORRECTIVA CHECK CONNECTION TO PUMP Mal funcionamiento en la conexi n entre la bomba y el Controler 0 bien La bomba tiene una temperatura inferior a 0 C Comprobar que el cable de conexi n entra en la bomba y el controler est bien fijado por ambos extremos y no est interrumpido Apretar dos veces el pulsador START para volver a poner en marcha la bomba WAITING INTERLOCK Est activa la se al de interlock presente en el conector P1 a causa de la interrupci n del cortocircuito entre el pin 3 y el pin 8 del conector J1 o a causa de la apertura de la se al de interlock externo Eliminar el cortocircuito entre el pin 3 y el pin 8 del conector P o cerrar la se al de interlock exterior PUMP OVERTEMP La temperatura del rodamiento superior o de la bomba ha superado los 60 C Esperar a que la temperatura vuelva por debajo del umbral Apretar dos veces el pul
47. e par un personnel agr En cas de panne il est possible de s adresser au Service de r paration Agilent ou bien au Agilent advance exchange service qui permet d obtenir un contr leur r g n r la place du contr leur d traqu WIS KS A ANR Avant d effectuer toute operation sur le contr leur d brancher le c ble d alimentation En cas de mise au rebut d un contr leur proc der son limination conform ment aux r glementations nationales en la mati re TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 47 297 3 Mode d emploi Mise au rebut 46 291 Signification du logo WEEE figurant sur les tiguettes Le symbole ci dessous est appligu conform ment a la directive CE nomm e WEEE Ce symbole unique ment valide pour les pays de la Communaut euro p enne indique que le produit sur lequel il est appliqu NE doit PAS tre mis au rebut avec les ordures m na g res ou les d chets industriels ordinaires mais passer par un systeme de collecte s lective Apr s avoir v rifi les termes et conditions du contrat de vente utilisateur final est donc pri de contacter le fournisseur du dispositif maison m re ou revendeur pour mettre en uvre le processus de collecte et mise au rebut TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Messages erreur Messages d erreur 3 Dans certains cas de panne ensemble de circuits autodiagnostic du contr leur p
48. en 4 1742 15 MW Odkazy kter upozor uj na nebezpe a donut oper tora aby se dil dle procedury nebo specifick praktiky kter nebude li f dn vykon na m e ohrozit va nym zp sobem jeho zdrav POZOR Tyto zpr vy byvaji vizualizov ny pred jakoukoliv procedurou je t eba se jimi fidit aby nedo lo k poSkozeni pfistroje Pozn mky vyjmut z textu obsahuj ve mi d le it informace Uskladn ni B hem dopravy a skladov n kontrol r se mus db t na n sledujici podm nky prost ed temperatura od 20 C do 70 C relativn vlhkost 0 95 nesm kondenzovat TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 161 297 13 Navod k Pou it Pr prava k instalaci Kontrol r je dod v n v speci ln m ochrann m balen objev li se n sledkem dopravy n jak po kozen je t eba se okam it obr tit na m stn prodejn servis B hem rozbalov n se obzvl mus d vat pozor aby kontrol r nespadl nebo aby neutrp l n razy Balic materi l se nesm odkl dat v p rod Tento materi l se m e kompletn recyklovat nebo se shoduje se sm rnicemi EU CEE 85 399 kter se t kaj ivotn ho prost ed Postava 1 Obal kontrol ru 162 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A N vod k Pou it 13 Instalace Kontrol r mus b t nap jen t dr tov m ka
49. f ljande avsnitten inneh ller all information som beh vs f r att garantera operat rens s kerhet under driften Detaljerade uppgifter finns i bilagan Technical information TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Bruksanvisning 8 I bruksanvisningen anv nds f ljande standard rubriker Varningsmeddelandena informerar operat ren om att en speciell procedur eller en viss typ av arbete m ste utf ras exakt enligt anvisningarna annat fall finns risk f r sv ra personskador 1d Detta varningsmeddelande visas framf r procedurer som m ste f ljas exakt f r att undvika skador p maskinen Detta visar p viktig information texten F rvaring F ljande krav pa omgivningsf rhallanden g ller vid transport och f rvaring av styrenheten temperatur fran 20 C till 70 C a relativ luftfuktighet 0 95 utan kondens TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 101 297 8 Bruksanvisning Forberedelser f r installation Styrenheten levereras i ett sarskilt skyddande emballage Kontakta det lokala f rs ljningskontoret om emballaget visar tecken p skador som kan ha uppst tt under transporten Se till att styrenheten inte tappas eller uts tts f r st tar vid uppackningen Kasta inte packmaterialet i soporna Materialet r tervinningsbart till 100 och uppfyller EU direktiv 85 399 om milj skydd ble AE 124 f W
50. il reset del controller ed una seconda volta per riavviare la pompa 5 Display alfanumerico a cristalli liquidi matrice di punti 2 linee x 16 caratteri TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 21 297 1 Istruzioni per uso Do ehe m Figura 3 Pannello posteriore dei Controller TwisTorr84 AG 1 Connettore di ingresso dei segnali logici il connettore di accoppiamento viene fornito con apposito ponticello di richiusura 2 Connettore segnali logici in uscita e monitoraggio frequenza pompa pi uscita analogica programmabile 3 Connettore di uscita alimentazione 24 Vdc per la ventola di raffreddamento pompa vent valve e calibro 4 Modulo di ingresso alimentazione controller che comprende i fusibili la presa di alimentazione ed il filtro ENC 5 Switch a rotazione per impostare indirizzo del Profibus 6 Profibus opzionale 7 Connettore seriale per controllo da remoto 8 Pompa 22 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Istruzioni per l uso 1 Procedure di uso Accensione del Controller Per accendere il controller sufficiente inserire il cavo di alimentazione nella presa di rete Avvio della Pompa Per avviare la pompa occorre abilitare l ingresso di interlock e premere il pulsante START del pannello frontale Arresto della Pom
51. is set to TIME or NORMAL TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 267 297 17 Technical Information Gauge Menu This menu contains the parameters relating to functioning of the active gauge I I I GAUGE i gt PRESSURE UNIT I GAS CORRECTION Flow 5 6 Figure 42 268 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Technical Information 17 PRESSURE UNIT selects the unit of measurement of the pressure used to show this on the display for display on the serial line and for setting of the setpoint and autopressure thresholds Possible options mbar a Pascal Torr GAUGE MODEL ID it shows the gauge model identified by the controller If there are more model with the same identification the user can select the right gauge connected GAS TYPE sets the gas type not configured Nitrogen Argon Idrogen Other gt ND EO CORRECTION if it is selected the gas type 4 Other you can set the correction factor of the pressure measurement for this kind of gas The pressure indicated by the instrument is equal to P indicated P measured x Gas correction 10 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 269 297 17 Technical Information 210 297 Serial Menu This menu contains the settings for management of the RS232 485 serial line
52. mukana vaan se on toimitettava erilliseen ker yspisteeseen Loppuk ytt j kehotetaan sen vuoksi ottamaan ker ys ja h vitt misprosessia varten yhteytt laitteen toimittajaan olipa se sitten laitteen valmistaja tai j lleenmyyj tarkastettuaan ensin kaupan sopimusehdot 132 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Vianetsint Ohjekasikirja 10 Joidenkin toimintahairi iden yhteydess valvojan itsem rittelypiiri analysoi virheen joka nakyy viesteina jotka on kuvailtu seuraavassa taulukossa Tab 1 VIESTI VIKA KORJAUSTOIMENPITEET CHECK CONNECTION TO PUMP Toimintah iri pumpun ja valvojan liitannassa Tai Pumpun l mp tila on alempi kuin 0 C Tarkistakaa ett pumpun ja valvojan v linen yhteyskaapeli on hyvin kiinnitetty p ist n eik sen varrella ole esteit Painakaa kaksi kertaa painonappia START jolloin pumppu k ynnistyy WAITING INTERLOCK Lukitussignaali interlock liittimess P on aktiivinen johtuen liittimen J1 neulojen 3 ja 8 v lill tapahtuneen oikosulun keskeytyksest tai ulkoisen lukitussignaalin interlock avautumisesta Palauttakaa liittimen P1 neulojen 3 ja 8 v linen oikosulku tai sulkekaa ulkopuolinen lukitussignaali interlock PUMP OVERTEMP Ylemm n laakerin tai pumpun lamp tila on ylitt nyt 60 C Odottakaa ett l mp tila putoaa kynnysarvon alapuolelle Painakaa painonappia START kaksi ke
53. nedo lo k p eru en Stisknout tla tko START dvakr t pro op tn spu t n erpadla WAITING INTERLOCK Aktivn sign l interlock se nach z na konektoru P1 nebo do lo k p eru en zkratu mezi pin 3 a pin 8 del konektoru J1 nebo kv li otev en sign lu vn j ho interlock Znovu obnovit spojen nakr tko mezi pin 3 a pin 8 konektoru P1 nebo uzav t sign l vn j ho interlock PUMP OVERTEMP Temperatura horn ho lo iska nebo erpadla p ev ila 60 C Po kat a se temperatura op t vr t pod mezn hodnotu Stisknout dvakr t tla tko START pro op tn spu t n erpadla CONTROLLER OVERTEMP Temperatura kontrol ru p ev ila 70 C Nebo Teplota radi toru kontrol ru je vy ne 60 C Vy kat az se temperatura op t vrati pod mezn hodnotu Stisknout dvakr t tla tko START pro op tn spu t n erpadla TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 169 297 13 170 297 N vod k Pou it ZPR VY POPIS KOREKCE TOO HIGH Absorbovan proud erpadla je Prov fit zda rotor erpadla se LOAD vy ne ten naprogramovan m e voln ot et Stisknout dvakr t tla tko START pro op tn spu t n erpadla SHORT B hem norm ln ho provozu po Prov rit spojen mezi CIRCUIT spou t c f zi v stupn spojen je erpadlem a kontrol rem ve zkratu Stisknout dvakr t
54. programmable power sp3 300 R N Cycle time in minutes zeroed by the reset 0 to 999999 command 301 R N Cycle number zeroed by the reset 0 to 9999 command TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 245 297 17 Technical Information 302 R N Pump life in hours zeroed by the reset 0 to 999999 command 320 Reserved to Agilent service to 399 400 R A CRC EPROM QE QE8XXXX where XXXX are variable 402 R A CRC Param PA PA8XXXX where XXXX are variable 404 R A CRC Parameter structure XXXX 500 Reserved to Agilent service 503 R W N RS 485 address 0 to 31 default 0 504 R W L Serial type select 0 RS 232 1 RS 485 default 0 1 Automatic means that when the controller stops the vent valve is opened with a delay defined by window n 126 when the controller starts the vent valve is immediately closed 2 On command means that the vent valve is opened or closed by means of window n 122 7 6 5 4 3 2 1 0 TOO HIGH LOAD NO CONNECTION SHORT CIRCUIT PUMP OVERTEMP OVERVOLTAGE CONTROLL OVERTEMP AUX FAIL POWER FAIL Figure 29 Window N 206 Bit Description 246 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Technical Information 17 How to Use by Front Panel VACUUM TECHNOLOGIES o0 OO Z
55. pump using the motor The Stop Speed reading reads the pump speed after a stop command Figure 25 Diagram 5 226 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A J2 Serial Connector Technical Information 17 This connector provides the connection for RS 232 and RS 485 serial line J2 Pin out 035050 ZA N 0000 O Figure 26 J2 Connector Tab 5 PINN SIGNAL NAME 5 V OUT Reserved TX RS232 RX RS232 NC GND A RS485 NC B RS485 co O M o o B G ND RESERVED TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 227 297 17 Technical Information Connector Examples 5 5 2 TwisTorr 84 FS AG PC 2 Rack Controller 3 3 Figure 27 RS 232 Connection PC HOST 0 TURBO CONTROLLER B 1 Gnd TURBO At CONTROLLER B 2 1209 V2W Figure 28 RS 485 Connection 228 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Technical Information 17 The communication port mating connector is supplied with the RS 232 PCB AMP Cannon or equivalent 15 pin D type male connector For example the Transmit data signal from controller pin 2 must be connected to the host computer s receive data line pin 2 and vice versa Consult the host computer s instruction manual for its serial port connections A
56. soglia Premere due volte il pulsante START per riavviare la pompa TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 25 297 1 Istruzioni per uso MESSAGGIO DESCRIZIONE AZIONE CORRETTIVA TOO HIGH LOAD La corrente assorbita dalla pompa maggiore di quella programmata Verificare che il rotore della pompa abbia la possibilit di ruotare liberamente Premere due volte il pulsante START per riavviare la pompa SHORT CIRCUIT Durante il funzionamento normale dopo la fase di avvio la connessione di uscita in corto circuito Verificare i collegamenti tra pompa e controller Premere due volte il pulsante START per riavviare la pompa SYSTEM OVERRIDE La pompa stata fermata da un segnale di emergenza proveniente da un contatto remoto Staccare il cavo di alimentazione del controller e correggere la causa dell emergenza Ricollegare il cavo di alimentazione e premere due volte il pulsante START per riavviare la pompa OVERVOLTAGE Si verificato un guasto nella sezione di alimentazione del controller o il controller ha ricevuto un segnale spurio Premere due volte il pulsante START per riavviare la pompa Se il messaggio si ripresenta rivolgersi in Agilent per la manutenzione POWER FAIL Guasto nella sezione di alimentazione della pompa del controller Rivolgersi alla Agilent per Manutenzione 26 297 TwisTorr 84 FS AG Rack Controlle
57. suficiente inserir o cabo de alimenta o na tomada de rede Activac o da bomba Para ligar a bomba ocorre habilitar a entrada de interlock e apertar o bot o START do painel frontal Paragem da bomba Para parar a bomba necess rio premer o bot o STOP do painel frontal Manutenc o Os controllers da s rie TwisTorr 84 Rack n o requerem qualquer manuten o Todas as opera es devem ser efectuadas por pessoal autorizado Em caso de defeito poss vel utilizar o servi o de repara o Agilent ou o Agilent advanced exchange service que permite obter um controller regenerado que substitua o controller com defeito PUBEN Antes de efectuar qualquer opera o no controller desligar o cabo de alimenta o Caso um controller deva ser destru do proceder sua elimina o respeitando as normas nacionais espec ficas TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 71 297 5 Manual de Istru es Eliminac o 12 291 Significado do log tipo WEEE presente nos r tulos O s mbolo abaixo indicado aplicado de acordo com a directiva CE denominada WEEE Este s mbolo v lido apenas para os pa ses da Comunidade Europeia indica que o produto no qual est aplicado N O deve ser eliminado juntamente com os res duos dom sticos ou industriais comuns mas deve ser dirigido a um sistema de recolha diferenciada Portanto convidamos o utilizador final a contactar o fornecedor do dispos
58. supply If a pump is to be scrapped it must be disposed off in accordance with the specific national standards TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 203 297 16 Instructions for Use Disposal 204 297 Meaning of the WEEE logo found in labels The following symbol is applied in accordance with the EC WEEE Waste Electrical and Electronic Equipment Directive This symbol valid only in countries of the European Community indicates that the product it applies to must NOT be disposed of together with ordinary domestic or industrial waste but must be sent to a differentiated waste collection system The end user is therefore invited to contact the supplier of the device whether the Parent Company or a retailer to initiate the collection and disposal process after checking the contractual terms and conditions of sale TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Error Messages Instructions for Use 16 For a certain type of failure the controller will self diagnose the error and the messages described in the following table are displayed Tab 1 MESSAGE DESCRIPTION REPAIR ACTION CHECK CONNECTION TO PUMP Wrong connection between the pump and the controller Or The pump s temperature is below 0 C Check connection between controller and pump Press the START push button twice to start the pump WAITING INTERLOCK The interlock signal of
59. the user as described in the Programming section of this manual a Press the MEASURES push button the display shows LJ TwisTorr 84 FS AG Figure 34 Where P lt is the DC power drawn by the pump range 0 to 999 Watt Hz is the rotational speed of the pump as a function of the controller output freguency C is the temperature of the outer ring of the upper bearing range 00 to 99 C TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 255 297 17 Technical Information 256 297 a Pressing MEASURES key twice the following screen page is displayed N O R MJ A L 9 6 3 H z L 1 2 O0 A Vi 4 Where I is the current supplied by the controller to the pump at that precise moment V is the voltage at which the controller is powering the pump at that moment Pressing the MEASURES key three times with the GAUGE connected and functioning the following screen page is displayed 7 4 E 0 5 m B A r X X X X VACUUMTECHNOLOGIES COUNTERS increase decrease LOW SPEED TwisTorr 84 FS AG O O Figure 35 Where mBar shows the
60. tla tko START pro op tn spu t n erpadla SYSTEM Pumpa byla zastavena nouzov m Odpojit nap jec kabel OVERRIDE sign lem prost ednictv m d lkov ho kontrol ru a napravit p inu kontaktu poplachu Znovu p ipojit nap jec kabel a stisknout dvakr t tla tko START pro op tn spu t n erpadla OVERVOLTAGE Vznikla porucha v nap jec sekci Stisknout dvakr t tla tko kontrol ru nebo kontrol r dostal START pro op tn spu t n fale n sign l erpadla Po op tn zpr v ohledn dr by je nutno se obr tit na Agilent POWER FAIL Porucha v nap jec sekci erpadla Ohledn dr by je t eba se kontrol ru obr tit na Agilent TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A TwisTorr 84 FS AG Rack Controller User Manual 14 N vod na Obsluhu V eobecn inform cie 172 Usklad ovanie 173 Pr prava pre in tal ciu 174 In tal cia 175 Pou itie 176 Povely Ukazovatele a Pr pojky Controller 177 Popis eln ho panelu 177 Postup pri pou it 179 Zapnutie Controller 179 Na tartovanie erpadla 179 Zastavenie erpadla 179 dr ba 179 Likvid cia 180 Oznamy v d 181 Preklad origin lneho n vodu RE Agilent Technologies 171 297 14 N vod na Obsluhu V eobecn Inform cie Tento pr stroj sl i k profesion lnemu pou itiu U vate si pred pou it m tohto pr stroja mus pozorne pre ta tento n vod k pou
61. under range or when the gauge give an internal error 4 gt when the identification is present but not known by the controller Win 267 Gauge power read write If you need to turn off the gauge at certain condition you can use this window 0 gt gauge off 1 gt gauge on default 2 gt gauge normally off It turns on when the set point 1 is activated If the set point 1 type win 101 is selected as pressure the gauge is always on 3 gt gauge normally off It turns on when the set point 1 is activated If the set point 2 type win 171 is selected as pressure the gauge is always on 4 3 gauge normally off It turns on when the set point 1 is activated If the set point 3 type win 101 is selected as pressure the gauge is always on The windows from 136 to 140 manage an additional set point set point 3 dedicated to turn ON or OFF the gauge win 267 4 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 225 297 17 Technical Information Pump Driving Typical pump driving chart start and normal operation 1200 160 1000 800 Power W Frequency Hz a S S Ph e RE Freg Hz Power W 50 100 150 200 250 300 350 400 Time s Figure 24 Diagram 4 Stop Speed Reading and Active Stop This functions can be activated by Front Panel or serial line Win 107 167 Active Stop brakes the
62. virransy tt osassa puoleen Huoltoa tarvittaessa 134 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A TwisTorr 84 FS AG Rack Controller User Manual 11 Felhaszn l i K zik nyv ltal nos inform ci k 136 T rol s 137 A telep t sre val el k sz t s 138 Telep t s 139 Haszn lat 140 A vez rl parancsai kijelz i s csatlakoz i 141 Az el lap le r sa 141 Haszn lati elj r sok 143 A vez rl bekapcsol sa 143 A szivatty beind t sa 143 A szivatty le ll t sa 143 Karbantart s 143 Megsemmis t s 144 Hiba zenetek 145 Az eredeti utas t s ford t sa RE Agilent Technologies 135 297 11 Felhaszn l i K zik nyv ltal nos inform ci k Ez a berendez s hivat sos haszn latra tervezett A felhaszn l nak a berendez s haszn lat t megel z en gondosan el kell olvasnia e felhaszn l i k zik nyvet s minden egy b a Agilent ltal szolg ltatott inform ci t A Agilent elh r t mag t l minden esetleges felel ss get mely a felhaszn l i utas t sok teljes vagy r szleges figyelmen k v l hagy s hoz a nem kik pzett szem lyzet ltal t rt n nem megfelel haszn lathoz meghatalmaz s n lk li beavatkoz sokhoz vagy a specifikus nemzeti ir nyelvekkel ellent tes haszn lathoz k t dik A TwisTorr 84 Rack sorozat vez rl k mikroprocesszoros vez rl s szil rdtest elemekkel realiz lt frekvencia talak t k ndiagnosztikai s saj
63. zaslonu parametrov cycle number cycle time in pump life 2 Tipka za LOW SPEED modus je aktivna samo nato ko ste izbrali to komando iz prednje plo e Ce gumb enkrat pritisnite rpalka vrti na hitrosti stand by Ce e enkrat pritisnite gumb izklju ite LOW SPEED modus 3 Tipka za preklic na zaslonu parametrov pump current pump power rotational speed temperatura spodnjega le i a temperatura gornjega le i a temperatura motora frekvenca vzburjenja Ta tipka je vedno aktivna neodvisno od modusa delovanja ki ste ga izbrali e skupaj pritisnite gumbe 3 in 1 za vsaj dve sekundi aktivirate program s katerim je mogo e nastaviti nekatere operativne prarmetre 4 Tipka za zagon komand START STOP RESET Aktivna je samo nato ko ste to komando izbrali iz prednje plo e e gumb enkrat pritisnite boste pognali rpalko e ga e enkrat pritisnete boste rpalko zaustavili e se je rpalka sama zaustavila zaradi kvara morate to tipko enkrat pritisniti da bi lahko controller a resetirali in e drugi za ponoven zagon rpalke 5 Alfa tevil ni zaslon iz teko ih kristalov prebijalo bodov 2 linije x 16 znaka TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 189 297 15 Priro nik za Navodila osado ol OE Slika 3 Ozadnja plo a Controllera TwisTorr 84 AG Vhodni konektor logi nih signalo
64. 037 01 A TwisTorr 84 FS AG Rack Controller User Manual Istruzioni per uso Informazioni Generali 16 Immagazzinamento 17 Preparazione per l installazione 18 Installazione 18 Uso 20 Comandi Indicatori e Connettori 21 Descrizione pannello frontale 21 Procedure di uso 21 Accensione del Controller 23 Avvio della Pompa 23 Arresto della Pompa 23 Manutenzione 23 Smaltimento 23 Messaggi di errore 25 Traduzione delle istruzioni originali En Agilent Technologies 15 297 1 Istruzioni per uso Informazioni Generali 16 297 Questa apparecchiatura e destinata ad uso professionale L utilizzatore deve leggere attentamente il presente manuale di istruzioni ed ogni altra informazione addizionale fornita dalla Agilent prima del utilizzo dell apparecchiatura La Agilent si ritiene sollevata da eventuali responsabilita dovute all inosservanza totale o parziale delle istruzioni ad uso improprio da parte di personale non addestrato ad interventi non autorizzati o ad uso contrario alle normative nazionali specifiche I controller della serie TwisTorr 84 Rack sono dei convertitori di frequenza controllati da un microprocessore realizzati con componenti a stato solido e con capacita di autodiagnostica e autoprotezione Caratteristiche del controller a Operativit frontale remota seriale a Pilotaggio a 24 Vdc della ventola di raffreddamento pompa a Pilotaggio vent valve a Lettura velocit pompa in seguito al commando
65. 117 297 9 Instruksjon Manual ED OE Figur 3 Bakpanelet p styreenheten TwisTorr 84 AG Inngangskontakt for logiske signaler tilkoplings kontakten leveres med spesiell lukkebrygge 2 Port for logiske signaler ut og monitoring av pumpefrekvens og analogisk utgang programmerbar 3 Port for mating ut 24 Vdc p kj levifte p pumpen vent valve og kaliber 4 Inngangsmodul til mating av styreenheten som best r av sikringer matekontakt og ENG filter 5 Dreiebryter for innstilling av Profibusadresse 6 Profibus valgfritt 7 Serialport for fjernkontroll 8 Pumpeport 118 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Instruksjon Manual 9 Instruksjoner for bruk Starte styreenheten Styreenheten startes ved sette stramkabelen i veggkontakten Starte pumpen For starte pumpen m man preparere interlockinngangen og trykke p knappen START p frontpanelet Stoppe pumpen Pumpen stoppes ved trykke p knappen STOPP p frontpanelet Vedlikehold TwisTorr 84 Rack seriens styreenheter er vedlikeholdsfrie Alt arbeid p styreenheten m kun utfgres av autorisert personell Dersom styreenheten stanser m du ta kontakt med Agilents reparasjonservice eller med Agilents avanserte bytteservice som kan tilby overhalte styreenheter til erstat
66. 2 Installation 103 Anv ndning 104 Instruktioner f r bruk 107 Underh ll 107 Bortskaffning 108 Felmeddelanden 109 Instruksjon Manual 111 Generell informasjon112 Lagring 113 Forberede installasjonen 114 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Contents Installasjon 115 Bruk 116 Instruksjoner for bruk 119 Vedlikehold 119 Eliminering 120 Feilmeldinger 121 10 Ohjek sikirja 123 Yleisi tietoja 124 Varastointi 125 Valmistelut asennusta varten126 Asennus 127 K ytt 128 K ytt toimenpiteet 131 Huolto 131 H vitt minen 132 Vianetsint 133 11 Felhaszn l i K zik nyv 135 ltal nos inform ci k 136 T rol s 137 A telep t sre val el k szit s138 Telep t s 139 Haszn lat 140 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 9 297 Contents 10 297 12 13 Haszn lati elj r sok 143 Karbantart s 143 Megsemmis t s 144 Hiba zenetek 145 Podrecznik Instrukcji 147 Informacje ogolne 148 Magazynowanie 149 Przygotowanie do instalacii 150 Instalacja 151 Uzytkowanie 152 Procedure uzytkowania 155 Konserwacja 155 Przetworstwo odpadow 156 Bledne informacje 157 N vod k Pou it 159 V eobecn informace 160 Uskladn ni 161 P prava k instalaci 162 Instalace 163 Pou it 164 Pou van procedury 167 dr ba 167 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Contents Likvidace 168 Chybn
67. 297 8 Bruksanvisning Anv ndning Detta avsnitt beskriver de viktigaste driftmomenten F r en detaljerad beskrivning samt betr ffande moment som involverar anslutningar eller tillbeh r h nvisas till avsnittet Use i bilaga Technical Information Innan styrenheten anv nds b r samtliga elektriska och pneumatiska anslutningar utf ras L s bruksanvisningen f r den anslutna pumpen F rs kra dig om att pumpen st r stadigt om den r installerad p ett bord detta f r att f rebygga skador p apparaten och personer S tt aldrig igang pumpen om intagsfl nsen varken r kopplad till systemet eller r blockerad p plats med l sfl nsen St ngningskontakten J1 m ste l mnas ansluten med aktuell brygga om ingen extern anslutning utf rs F rvakuumpumpen och TwisTorr pumpen kan fungera samtidigt 104 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Bruksanvisning 8 Indikatorer och Kontakterp Styrenheten Nedan visas styrenhetens front och bakpanel F r ytterligare information h nvisas till bilaga Technical Information Beskrivning av frontpanel 1 3 2 4 Figur 2 Frontpanelen p Styrenheten TwisTorr 84 AG 1 Tryckknapp f r att h mta parametrarna cycle number cycle time och pump life p displayen 2 Tryckknapp f r inst llning av LOW SPEED drifts tt Tryckknappen fungerar enda
68. 65535 corresponding to sec 0 to 13107 sec 130 Reserved to Agilent service 136 R W N Gauge Set Point Type 0 Freg 1 Power 2 Time 3 Normal default 137 R W N Gauge Set Point Value Hz W s default 867 138 R W N Gauge Set Point Mask sec default 0 139 R W L Gauge Set Point Segnal Activation Type 0 high level active default 1 low level active 140 R W N Gauge Set front Mysteresis in of R2 default 2 Valve 143 R W N External Fan Configuration 0 0N 1 automatic 2 serial default 2 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 243 297 17 Technical Information 144 R W L External Fan Activation 0 OFF 1 ON default 0 147 R W N Vent open time 0 infinite See vent connector paragraph 1 bit 0 2 sec 155 R N Power limit applied watt Read the maximun power deliverable to the pump 157 R W N Gas load type O N2 Select the gas load to the pump 1 Av 162 R W A R1 Set Point Pressure Threshold Valid if min 101 4 Format X X EsXX Where X 0 to I s or 163 R W N Pressure unit of measure 0 mBar 1 Pa 2 Torr 167 R W A Stop speed reading 0 disable Activates deactivates the pump speed 1 enable reading after Stop command 171 R W N R2 Set Point Type 0 Freg 1 Power 2 Time 3 Normal default 3 4 Pressure available only if the gauge is connected 172 R W N R2 Set Point Value Hz W s 173 R W R2 Set
69. 7 15 Priro nik za Navodila Uporaba SVARILO V tem odsatvku so navedeni vsi glavni operativni postopki Za dodatne detalje in postopke ki zadevajo priklju itve ali posamezne opcije si lahko ogledate odstavek Use v priponki Technical Information Predno bi uporabili controller morate priklju iti vse elektri ne in pnevmatske kable pri tem se nanaj ate na priro nik prilo ene rpalke Da bi se izognili po kodbam bodisi oseb kot naprave morate poskrbeti da ste rpalko stabilno polo ili e ste jo vgradili na mizi rpalka ne sme nikoli delovati e vhodna prirobnica ni priklopljena k sistemu ali e ni zaprta s zapiralno prirobnico Zapiralni konektor J1 mora ostati priklju en k svojemu mosti ku e niste izvr ili nikakr ne druge zunanje priklju itvije rpalko predhodnega praznjenja in rpalko TwisTorr lahko isto asno vklopite 186 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Priro nik za Navodila 15 Komande indikatorji in konektorji Sledi prikaz prednje in ozadnje plo e controllera Za podrobnej e informacije si ogledajte paragraf Technical Information Opis prednje plo e 1 VACUUMTECHNOLOGIES 3 COUNTERS increase g L menu lar TwisTorr 84 FS AG O Slika 2 Prednja plo a Controllera TwisTorr 84 AG 1 Tipka za preklic na
70. C See following chart for more details 9 1 Frequency Analog output proportional to Optically isolated Analog Output frequency linear OV 0Hz 10V 1010Hz Rload min 10kohm Ripple Vpp max 200mV Precision 1 Resolution 40mV Pin 1negative Pin 9 positive TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 219 297 17 Technical Information R1 R2 Output Diagrams F Hz as DO 963 ue Ge po Value 0 V Volt SSE R WERE Li o i t sec Mask Time Figure 14 Diagram 1 R1 or R2 related to frequency Mask Time Figure 15 Diagram 2 R1 or R2 related to power 220 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Technical Information 17 V Volt R1 R2 24 9 a Value Start Command Mask Time and Hyst ignored t sec Figure 16 Diagram 3 R1 or R2 related to time V Volt R1 R2 Stop Waiting Ramp Auto i Braking Interlock tuning Normal Fail t sec Figure 17 Diagram 4 R1 or R2 related to Normal status Pressure Only if gauge 4 A Mask Time M o Threshold Value 5 lt lt Threshold gt k t sec V Volt A t sec Figure 18 Diagram 5 R1 or R2 related to pressure reading if gauge connected TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 221 297 17 Technical Informatio
71. CDG3 CDG 500 TO100 CDG2 CDG 500 T0010 CDG1 CDG 500 T0001 CDGO TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 223 297 17 Technical Information The controller give the error gauge error if the gauge connected is not supported The pressure can be read by dispaly or by serial line win 224 or by REMOTE I O on Programmable Analog Out If the Programmable Analog Output is related to the pressure read by an external gauge the controller doesn t replicate exactly the signal coming from the gauge the controller converts the gauge signal in the range from 0 to 10V The conversion formula is the following VV a za m S 10 V g max Fe min Where V is the gauge output voltage Vout is the Analog Output voltage Vo min Vg max is the gauge voltage measuring range these values can be drawn from the gauge technical specifications J5 GAUGE IDENTIFICATION SIGNAL SIGNAL COMMON 25VDC COMMON Figure 23 Gauge Connector 224 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Technical Information 17 With the serial communication you can use the following windows Win 224 Pressure reading with the format X X E XX Win 257 Gauge status read only 0 gt when a gauge is not connected 1 gt when a gauge is connected 2 gt when the pressure read is under range or when the gauge give an internal error 3 gt when the pressure read is
72. CHING LOW SPEED R2 status 0 OFF 1 0N R1 status 0 OFF 1 0N 2 CRC 234 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Technical Information 17 When the Request is J Numerical readings the Answer will contain a string of 5 characters with the following parameters Tab 11 BYTES MEANING 1 Current 0 255 scaled 2 Voltage 0 255 scaled 3 Rotational speed KRPM 4 Pump temperature C 0 254 temperature reading 255 fail 5 CRC When the Request is K Counters readings the Answer will contain a string of 11 characters with the following parameters Tab 12 BYTES MEANING 1 4 Cycle time 5 8 Pump life 9 10 Cycle number 11 CRC On request a sample program in QBasic language is available by Agilent TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 235 297 17 Technical Information Window Protocol Description Communication Format 8 data bit a no parity a 1 stop bit a baud rate 600 1200 2400 4800 9600 programmable Communication Protocol The communication protocol is a MASTER SLAVE type where Host MASTER a Controller SLAVE The communication is performed in the following way 1 the host MASTER send a MESSAGE CRC to the controller SLAVE 2 the controller answer with an ANSWER CRC to the host The MESSAGE is a string with the following format lt STX gt lt ADDR gt lt WIN gt lt COM gt
73. Manuale di istruzioni Bedienungshandbuch Notice de mode emploi Manual de istrucciones Manual de istruc es Bedrijfshandleiding Istrukstionsbog Bruksanvisning 87 901 037 01 A 11 2014 ote Agilent Technologies TwisTorr 84 FS AG Rack Controller Models X3508 64001 X3508 64002 Instruksjon manual Ohjek sikirja Felhaszn l i k zik nyv Podrecznik instrukcji N vod k pou it N vod na obsluhu Priro nik za navodila User Manual Notices Agilent Technologies Inc 2014 No part of this manual may be reproduced in any form or by any means including electronic storage and retrieval or translation into a foreign language without prior agreement and written consent from Agilent Technologies Inc as governed by United States and international copyright laws Manual Part Number Publication Number 87 901 037 01 A Edition Edition 11 2014 Printed in ITALY Agilent Technologies Italia S p A Vacuum Products Division Via F lli Varian 54 10040 Leini TO ITALY Warranty The material contained in this document is provided as is and is subject to being changed without notice in future editions Further to the maximum extent permitted by applicable law Agilent disclaims all warranties either express or implied with regard to this manual and any information contained herein including but not limited to the implied warranties of merchantability and fitness for a particular purpose Agilen
74. P1 connector is activated by an interruption of the link between pin 3 and 8 of J1 connector or because the external interlock signal is open Reset the short circuit between pin 3 and pin 8 of P1 connector or close the external interlock signal PUMP OVERTEMP The upper bearing pump temperature exceeds 60 C Wait until the temperature decrease below threshold value Press the START push button twice to start the pump CONTROLLER OVERTEMP The controller environment temperature exceeds 70 C or The controller s radiator temperature is above 60 C Wait until the temperature decrease below threshold value Press the START push button twice to start the pump TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 205 297 16 206 297 Instructions for Use MESSAGE DESCRIPTION REPAIR ACTION TOO HIGH LOAD The current drawn by the pump is higher than programmed Check that the pump rotor is free to rotate Press the START push button twice to start the pump SHORT CIRCUIT After the starting phase the output connection is shorted Check connections and shortages between pump and controller Press the START push button twice to start the pump SYSTEM OVERRIDE The pump is stopped by an emergency stop signal provided via a remote contact Remove the controller power cable and check the emergency condition Then reconnect the power cable
75. S a next menu 2 4 Ge E START STOP TwisTorr 84 FS AG O Figure 2 Controller TwisTorr 84 AG Front Panel 1 Keyboard push button to recall on the display the cycle number cycle time and pump life 2 Keyboard push button for LOW SPEED mode selection lt is active only when the front panel operation has been selected Pressed once the pump runs at stand by speed To unselect the mode press the push button again 3 Keyboard push button to recall on the display the pump current pump temperature pump power and rotational speed It is always active regardless of the operating mode selected Push buttons 3 and 1 if pressed together for at least 2 seconds put the controller in a routine where it is possible to program some operation parameters 4 Keyboard push button for START STOP RESET mode selection It is active only when the front panel operation has been selected By pressing once the starting phase begins if pressed again it stops the pump If the pump has been stopped automatically by a fault this push button must be pressed once to reset the controller and a second time to restart the pump 5 LCD back lighted alphanumeric display dot matrix 2 lines x 16 characters TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 201 297 16 Instructions for Use O os So So go So So So Oije
76. S LOW SPEED speed become INCREASE and DECREASE and make it possible to select the next or previous value of a parameter in the case of compulsory parameters or to increase decrease the individual digit of a parameter in the case of numeric parameters The MEASURES and START STOP buttons become NEXT and PREVIOUS and make it possible to select the next parameter or next digit of a numeric parameter or previous parameter 258 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Technical Information 17 Switching from one parameter to the next using the NEXT key indicates confirmation of any changes made to the specific parameter If the changes cannot be accepted by the controller the Data out of limits error message is displayed the changes are cancelled and the value of the parameter prior to the modification is reproposed Switching from a parameter to the previous parameter using the PREVIOUS key indicates the intention to abort any changes made to the specific parameter Abort is indicated by the caption Changes aborted that is displayed for approx 1 second before moving to the previous parameter The configuration environment has a tree like structure and permits circular navigation on reaching the end of a branch the user is returned automatically to the start of this Navigation can proceed in a forwards NEXT button or backwards PREVIOUS button direction
77. TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 153 297 12 Podrecznik Instrukcji odo ol OE Posta 3 Pulpittylny kontrolerow TwisTorr 84 AG Lacznik wejsciowy sygnalow logicznych lacznik blizniaczy jest dostarczany z specialnym mostkiem zamykajacym 2 Lacznik wyjsciowy sygnalow logicznych i nadzor nad czestotlowoscia na wyjsciu podczas zaprogramowanej wielokrotnej pracy pompy 3 Lacznik zasilania na wyjsciu 24 Vdc dla turbiny chlodzacej pompy vent valve i kaliber 4 Modul wejsciowy zasilania kontrolera zawierajacy bezpieczniki topikowe gniazdko zasilajace i filtr ENC 5 Switch obrotowy do ustawiania kierunku Profibus 6 Profibus dodatkovvy 7 Lacznik seryjny do kontroli na odleglosc 8 Lacznik pompy 154 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Podrecznik Instrukcji 12 Procedure uzytkowania Zaswiecenie kontrolera Do zaswiecenia kontrolera wystarczy wprowadzic kabel zasilajacy do gniazdka sieci Uruchomienie pompy Zeby uruchomic pompe nalezy odblokowac wejscie interlock i nacisnac znajdujacy sie na pulpicie frontalnym przycik START Zatrzymanie pompy Do zatrzymania pompy wystarczy nacisnac przycisk STOP znajdujacy sie na pulpicie frontalnym Konserwacja Kontroler z serii TwisTorr 84 Rack nie wymaga zadnej konserwacji Jakakolwiek inte
78. a ito okolja E L Id dt sh Slika 1 Embala a controllera TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Priro nik za Navodila 15 Monta a Controller ima napajalni vod s tremi icami gledaj tudi preglednico delov ki lahko naro i in mednarodno priznan vtika za varnost uporabnika Uporabljajte vedno ta napajalni kabel in vtaknite vtika v vti nico z ustreznim masovnim vezanjem ker druga e vas lahko strese elektri ni tok in da se tako pridr ite ES meril Znotraj controller jev se stvori visoka napetost ki lahko loveku povzro i hude po kodbe ali celo smrt Preden bi nadaljevali s katerokoli dejavnostjo monta e ali pa vzdr evanja izklopite controller iz vti nice Controller lahko montirate na mizo ali vgradite v notranjost ustreznega rack a V vsakem slu aju morate poskrbeti da voda za hlajenje prosto kro i skozi napravo Controller a ne smete montirati ali uporabiti v okolici ki je izpostavljena klimatskim dejavnikom de ju ledu snegu prahu agresivn m plinom v okolici kjer obsatja nevarnost vnetja ali po ara Med delovanjem morate zagotoviti naslednje pogoje okolice temperatura od 5 C do 45 C a relativna vlaga 0 95 ne kondezna Kar se ti e priklju kov in monta e opcionalnih dodatkov si lahko ogledate priponko Technical Information TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 187 29
79. a nenhuma ligac o externa A bomba de pr v cuo e a bomba TwisTorr podem ser ligadas simultaneamente 68 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Manual de Istru es 5 Comandos Indicadores e Conectores A seguir est o ilustrados o painel de comando do Controller e os pain is de interconex o Para maiores detalhes consultar a secc o Technical Information Descric o painel frontal 5 1 VACUUM TECHNOLOGIES 3 COUNTERS C U MEASURES 2 e G sia 4 LOW SPEED 2 START STOP TwisTorr 84 FS AG O Figura 2 Painel frontal do Controller TwisTorr 84 AG 1 Bot o para evidenciar no display os par metros cycle number cycle time e pump life 2 Bot o para a selec o do modo LOW SPEED activo somente quando for seleccionado o modo de comando do painel frontal Apertando uma vez a bomba roda com velocidade stand by Apertando o novamente desactiva se o modo LOW SPEED 3 Bot o para evidenciar no display os par metros pump current pump temperature pump power e rotational speed sempre activo independentemente do modo de funcionamento escolhido Apertando os bot es 3 e 1 em conjunto pelo menos 2 segundos activado um programa com o qual poss vel programar alguns par metros operativos 4 Bot o para enviar os comandos de START STOP RESET activo somente quando for seleci
80. a od zaprogramowanej przeszkod w swobodnym obrocie Nacisnac dwa razy przycisk START dla ponownego uruchomienia pompy SHORT Podczas normalnej pracy po fazie Sprawdzic polaczenie pompy z CIRCUIT uruchomienia na wyjsciu sa kontrolerem zwarcia Nacisnac dwa razy przycisk START dla ponownego uruchomienia pompy SYSTEM Pompa sie zatrzymala na skutek Odlaczyc kabel zasilania OVERRIDE sygnalu zagrozenia pochodzacego kontrolera i sprawdzic od pierwotnego kontaktu przyczyne powstania sygnalu zagrozenia Podlaczyc ponownie kabel zasilajacy nacisnac dwa razy przycisk START dla ponownego uruchomienia pompy OVERVOLTAGE Nastapilo uszkodzenie w sekcji Nacisnac dwa razy przycisk zasilania kontrolera lub kontroler START dla ponownego otrzymal sygnal nieprawidlowy uruchomienia pompy Jezeli sygnal sie powtorzy zwrocic sie do Agilent o przeprowadzenie konserwacji POWER FAIL Uszkodzenie w sekcji zasilania Zwrocic sie do Agilent w celu pompy kontrolera naprawy TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A TwisTorr 84 FS AG Rack Controller User Manual 13 N vod k Pou it V eobecn informace 160 Uskladn ni 161 P prava k instalaci 162 Instalace 163 Pou it 164 Ovladani indik tory a konektory 165 Popis eln ho panelu 165 Pou van procedury 167 Zapalov n Kontrol ru 167 Spou t n erpadla 167 Zastaven erpadla 167 dr ba 167 Likvidace 168 Chybn zpr vy 169 P eklad or
81. al 87 901 037 01 A Technical Information All the logic output from the controller must be connected at P2 mating connector The following table describes the signals available on the connector The following figure shows a typical logic output connection relay coil but any other device may be connected e g a LED a computer etc and the related simplified circuit of the controller CONTROLLER Figure 12 Digital Output Connection Example 1 gt 100 KO 2 Figure 13 Analog Output Connection Example 17 217 297 17 Technical Information Tab 4 Pins Name Description Electrical Note 15 8 Fault 0V no fail Optically isolated Connect a 10kohm 24V fail Vmax open 24v resistor between the Vlow max 1 5v 2 pins before Imax 60mA measuring voltage Pin 8 negative A STOP command Pin 15 positive by front Panel or serial or Start stop input reset the FAIL status 13 6 Start Configurable output Optically isolated Connect a 10kohm Default setting win 177 0 Vmax open 24v resistor between the 24V pump in RAMP state OV Vlow max 1 5v 2 pins before other state If win 177 1 Imax 60mA measuring voltage OV pump in stop or FAIL Pin 6 negative status 24V other state Pin 13 positive 12 5 Low Speed 24V low speed active Optically isolated Connect a 10kohm 0V low speed not active Vmax open 24v resistor between the Vlow max 1
82. ar 1 Pascal 2 Torr B7 Reserved 21 1 Bo 2 Setpoint R1 Type 101 0 frequency 1 current 2 time 3 normal operation 4 pressure B3 5 Setpoint R2 Type 171 0 frequency 1 current 2 time 3 normal operation 4 pressure Bs 7 Analog Output 1 Type 111 0 frequency 1 power 2 temperature 3 pressure TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 279 297 17 Technical Information Output Buffer Tab 19 Output buffer Offset Size Byte Byte Unit Res Range Description WIN Serial 0 1 B7 Start Stop 0 Stop 1 Start 000 Bs Low Speed This bit set the pump target speed to low speed value Output Buffer Offset 3 otherwise the target speed is set to high speed value Output Buffer Offset 1 0 0ff 1 On 001 B5 Soft Start This bit activates the soft start function which run up the pump smoothly Please activate this function only if the pump has been stopped for at least3 months 0 On 1 Off 100 Ba Vent Valve Command 0 Close 1 Open Valid only if in Par Buff Offset 20 Bo 1 122 B3 Purge Valve Command 0 Close 1 Open Valid only if Par Buff Offset 20 Bo 1 145 B2 Not used Bo1 Operating Mode These bits define from which source the controller has to get commands readings are always available In order to operate the controller by Profibus these bits must be set to 3 0 R
83. at X XE XX when it is used for pressure monitoring Parameter Buffer Offset 21 B3 5 4 The value set here is divided by 10 that means 11 1 1 18 1 10 10 Setpoint 2 Pressure Value Exponent 176 Set the exponent of the exponential value of the R2 setpoint format X XE XX when it is used for pressure monitoring Parameter Buffer Offset 21 B3 5 4 19 1 Bo Stop Speed Reading 167 This function measures the pump speed after a stop command 0 Off 1 0n B1 Active Stop 107 This function brakes the pump after a stop command by using the motor as a generator 0 Off 1 0n B2 Reserved B34 Start Stop Interlock Mode 151 Change the logic of Start Stop and Interlock inputs Ask to Agilent personnel for this option 278 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Technical Information 17 20 1 Bo Vent amp Purge Auto Man 125 0 Auto the controller drives purge and vent valves automatically 1 Manual the user can command the valves by serial line or profibus Bi Gas Load Type Select here the gas load 157 0 Ar 1 N2 B2 Interlock Type 110 0 continuos the interlock must be always present to run the pump 1 atstart the interlock must be present only at start command B3 Setpoint R1 Logic 104 0 active close NO 1 active open NC B4 Setpoint R2 Logic 174 0 active close NO 1 active open NC B5 6 Pressure Unit 163 0 mb
84. att van Ellen rizni hogy a szivatty s a vez rl k zti sszek t k bel mindk t v g n j l van e r gz tve s nincs e megszakadva A szivatty jraind t s hoz k tszer megnyomni a START nyom gombot WAITING INTERLOCK A PI csatlakoz reteszel s jelen jele akt v a J1 csatlakoz 3 s 8 pin je k zti r vidz r megszakad sa vagy a k ls reteszel jel nyitott llapota k vetkezt ben Vissza ll tani a P1 csatlakoz 3 s 8 pin je k zti r vidz rat vagy z rni a k ls reteszel jelet PUMP OVERTEMP A fels csap gy vagy a szivatty h m rs klete meghaladta a 60 C t V rakozni m g a h m rs klet a k sz b rt k al esik A szivatty jraindit s hoz k tszer megnyomni a START nyom gombot CONTROLLER OVERTEMP A vez rl nak h m rs klete t ll pte a 70 C t vagy a vez rl h t s nek h m rs klete t ll pte a 60 C t V rakozni m g a h m rs klet a k sz b rt k al esik A szivatty jraindit s hoz k tszer megnyomni a START nyom gombot TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 145 297 11 146 297 Felhaszn l i K zik nyv ZENET LE R S JAV T SI TEV KENYS G TOO HIGH A szivatty ltal felvett ram Ellen rizni hogy a szivatty LOAD meghaladja a programozott forg r sze szabadon foroghat rt ket e A szivatty ujraindit s hoz k tsz
85. avirajicim m stkem 2 Konektor v stupn ch logick ch sign l a monitorov n frekvence erpadla plus naprogramovateln analogov v stup 3 Konektor v stupu nap jen 24 Vdc na ochlazovac lopatku erpadla vent valvea a kalibr 4 Vstupn nap jec modul kontrol ru kter zahrnuje i tavn pojistky nap jec z suvku a filtr ENC 5 Rota n switch na stanoven Profibusov adresy 6 Profibus op n 7 Seri ln konektor na d lkovou kontrolu 8 Konektor erpadla 166 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A N vod k Pou it 13 Pou van procedury Zapalov ni Kontrol ru Kontrol r se zapne vlo en m kabele do z suvky na s ti Spou t n erpadla Ke spu t n cerpadla je tfeba opr vnit vstup interlocku a stisknout tla tko START na eln m panelu Zastaven erpadla erpadlo se zastav stisknut m tla tka STOP na eln m panelu Udrzba Kontrol r s rie TwisTorr 84 Rack nevy aduj dnou dr bu Jak koliv z sah mus b t vykon v n jen opr vn n m person lem V p pad poruchy se m e vyu t oprav sk ho servisu Agilent nebo Agilent advanced exchange service kde po kozen kontrol r bude vym n n za nov NMA 124234180 Nejd ve p ed jak mkoliv z sahem na kontrol ru se mus odpojit elektrick kabel Bude li zapot eb kontrol r likvidovat mus se postupovat dle platn
86. avitev vhodne napetosti V naslednjih odstavkih so navedene vse informacije potrebne za zagotavljanje sigurnosti uporabnika med rokovanjem s to napravo Podrobnej e informacije dobite v priponki Technical Information TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Priro nik za Navodila 15 V tem priro niku so varnostne informacije razvr ene v dva razreda SVARILO Znak svarila opozarja uporabnika da mora pri dolo enem postopku ali pri posebnem delovanju paziti Kr itev svarila lahko privede do la jih ali hudih telesnih po kodb POZOR Znak pozor se pojavi pred postopke ki e jih uporabnik zanemari lahko napravo po koduje Opombe vsebujejo vse najbolj pomembne informacije iz besedila Skladi enje Med prevozom in skladi enjem controllerjev morate zagotoviti naslednje pogoje okolice a temperatura od 20 C do 70 C a relativna vlaga 0 95 bez kondenzacije TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 185 297 15 Priro nik za Navodila Priprava za monta o 186 297 Controller dobite v posebni za itni embala i e so na embala i znaki po kodbe ki naj bi nastale med transportom obrnite se krejavnemu prodajalnemu biroju Pri odstranitvi embala e morate e posebno paziti da controller ne pade na tla ali da ne podlegne udarcem Ne zavrzite embala e v okolico Material lahko v celoti reciklirate in ustreza direktivi CEE 85 399 za z
87. belem viz tabulku sou st kter lze objednat se z str kou shodnou s mezin rodn m standardem kter zaru uje bezpe nost u ivatele V euveden kabel je t eba neust le pou vat z str ku zasunovat do z suvky s adekv tn uzem n m spojen m aby se p ede lo elektrick m v boj m a aby se respektovaly sm rnice CE Uvnit kontrol ru doch z k vysok m nap t m kter jsou velmi nebezpe n i smrt c P ed proveden m jak koliv instala n i dr bov pr ce na kontrol ru je t eba ho odpojit od p konu Kontrol r m e b t nainstalov n na stole nebo uvnit p slu n ho rack V ka d m p pad je t eba aby okolo p stroje mohl vzduch voln proudit Kontrol r se nesm instalovat v m stech vystaven ch atmosferick m vliv m d mr z sn h prachu agresivn m plyn m na v bu n ch m stech nebo na m stech kde existuje velk riziko po r B hem provozu je t eba aby se respektovaly n sleduj c podm nky t kaj c se operativn ho prost ed a teplota od 5 C do 45 C a Relativni vlhkost 0 95 nesm kondenzovat Pro dal spojen a instalaci op n ho p slu enstv je t eba se pod vat do sekce Technical Information TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 163 297 13 Navod k Pou it Pou it V tomto odstavci jsou uvedeny hlavn operativn postupy Pro dal detajly i pro procedury t
88. cables SIGNAL GROUND RxD TxD P CRTR P SIGNAL GROUND 5V 24V RxD TxD N FEMALE CONNECTOR O JO J JO a GW IN Figure 45 ProfiBus connector TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 273 297 17 Technical Information Configuration Before power on the controller set the ProfiBus address by the 2 rotary switches Up to 126 different addresses from 0 to 125 can be selected The address value sets by the 2 switches is expressed in hexadecimal notation so value from 00 to 7D are permitted this setting is read by the interface during the power on phase so any change of the switch position after the power on is ignored Software Operation and State Machine From the software point of view the interface can be seen as two devices one for ProfiBus and the other for the internal link linked together Each device has its own state machine to manage the device operation Profibus link state machine Figure 46 Tab 16 Profibus state machine 274 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Technical Information 17 Status POWER_ON Interface set up WAIT PRM Wait for parameterisation from the master WAIT_CFG Wait for configuration from the master DATA_EX Regular data exchange Internal link state machine U U Figure 47 Tab
89. cje przyklady sa wymienionee w ponizszej tabeli Tab 1 INFORMACJA OPIS AKCJA KORYGUJACA CHECK CONNECTION TO PUMP Zaklocenia na polaczeniu miedzy pompa i kontrolerem Lub Temperatura pompy jest ponizej 0 C Zweryfikowac czy kabel laczacy pompe z kontrolerem jest dobrze zamocowany na obydwu koncach czy nie jest przerwany Nacisnac dwa razy przycisk START dla ponownego uruchomienia pompy WAITING INTERLOCK Jest aktywny sygnal Interlock na laczniku P1 spowodowany zwarciem pomiedzy pin 3 pin 8 lacznika J1 Lub na skutek otwarcia sygnalu zewnetrznego interlock Dokonac naprawy obwodu elektrycznego pomiedzy pin 3 i pin 8 lacznika P1 lub zamknac sygnal interlock zewnetrzny PUMP OVERTEMP Temperatura gornego lozyska lub pompy przekroczyla 60 C Odczekac az temperatura sie obnizy ponizej ustalonego poziomu Nacisnac dwa razy przycisk START dla ponownego uruchomienia pompy CONTROLLER OVERTEMP Temperatura w kontrolerze przekroczyla 70 C Lub Temperatura grzejnika nie przekracza 60 C Odczekac az temperatura sie obnizy ponizej ustalonego poziomu Nacisnac dwa razy przycisk START dla ponownego uruchomienia pompy TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 157 297 12 156 297 Podrecznik Instrukcji INFORMACJA OPIS AKCJA KORYGUJACA TOO HIGH Absorpcja pradu przez pompe jest Sprawdzic czy wirnik nie ma LOAD wyzsz
90. d by a new model see orderable parts table Vent Valve A CLOSED OPEN lt gt lt gt lt gt lt gt lt gt i i i STOP RAMP i NORMAL Vent Valve Relay Vent Valve Open i Win 126 Time Win 147 o o START COMMAND STOP COMMAND Figure 8 Vent Valve diagram in Auto mode 214 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A P1 Input Technical Information 17 P1 IN MALECONNECTOR ojp s o o ja o un SOFT START COM SYSTEM OVERRIDE COM INTERLOCK COM LOW SPEED COM START Figure 9 P input connector All the logic input to the controller must be connected at J1 mating connector With the provided P1 mating connector shipped with pin 3 and pin 8 shorted make the connections with AWG 24 0 24 mm2 or smaller wire to the pins indicated in the figure to obtain the desired capability The following table describes the signals available on the connector Tab 3 Pins Name Description Electrical Note 1 com Start Stop Contact closed Start Optically isolated Active only in Contact open lt Stop Vlow max lt 10v Remote Mode Imax lt 5mA operation Imin on 2m A 2 com Low Speed Contact closed Low Speed Optically isolated Active only in Contact open High Speed Vlow max 10v Remote Mode Imax 5mA operation 3 com Interlock Contact closed Active Optically isolated Active in all Contact open Inacti
91. d kikapcsol sra ker l 3 Nyom gomb a param tereknek szivatty ram a szivatty h m rs klete szivatty teljes tm ny s a forg si sebess g kijelz re val leh v s ra Mindig akt v f ggetlen l a kiv lasztott zemm dt l A 3 as s 1 es nyom gombot egy tt legal bb 2 m sodpercig nyomva tartva egy program ker l aktiv l sra melynek seg ts g vel n h ny zemi param ter programozhat 4 Nyom gomb a START STOP RESET parancsok ind t s ra Csak akkor akt v amikor az el lapr l a parancsm d ki lett v lasztva Egyszer megnyomva az ind t si f zis ker l aktiv l sra m g egyszer megnyomva a szivatty le ll t sra ker l Ha a szivatty valamely hiba k vetkezt ben automatikusan le ll ezt a nyom gombot kell megnyomni az els megnyom sra a vez rl null z dik reset a m sodikra a szivatty jraindul 5 Folyad kkrist lyos alfanumerikus kijelz pontm trixos 2 sor x 16 karakter TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 141 297 11 Felhaszn l i K zik nyv ED OE bra 3 A TwisTorr 84 AG sz m vez rl k h tlapja Logikai jelek bemeneti csatlakoz ja az sszek t csatlakoz megfelel lez r tk t ssel jumper van ell tva 2 Csatlakoz a kimeneti logikai jelek a szivatty frekvencia
92. de ich nedodr ania m u po kodi pr stroj Pozn mky zahr uj d le it inform cie vytiahnut z textu Usklad ovanie Po as prepravy a usklad ovania Controllers musia by dodr an tieto podmienky prostredia a teplota od 20 C do 70 C relat vna vlhkos 0 95 bez kondenz tu TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 173 297 14 N vod na Obsluhu Pr prava pre in tal ciu 174 297 Controller je dodan v peci lnom ochrannom obale keby ste objavili kodu sp soben prepravou skontaktujte sa s kancel riou miestneho predaja Pri rozba ovan d vajte pozor aby v m Controller nespadol alebo niekde nenarazil Obal nezahadzujte Je vyroben z recyklovate n ho materi lu a zodpoved smernici CEE 85 399 pre ochranu ivotn ho prostredia E L Id dt sh Postava 1 Obal Controller TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A N vod na Obsluhu 14 In tal cia Controller mus by napojen na sie s trojd tov m nap jac m k blom vi tabu ku objedn vaj cich s iastok so z str kou ktor zodpoved medzin rodnej rovni a tak zabezpe uje bezpe nos u vate a Pou vajte v hradne tento nap jac k bel a z str ku zas vajte do z str ky ktor m vhodn uzemnenie aby ste sa vyhli elektrick mu v boju T to mus re pektova stanoven
93. der Eingangsspannung In den folgenden Abschnitten sind alle erforderlichen Informationen f r die Sicherheit des Bedieners bei der Anwendung des Ger ts aufgef hrt Detaillierte technische Informationen sind im Anhang Technical Information enthalten TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Gebrauchsanleitung 2 In dieser Gebrauchsanleitung werden Sicherheitshinweise folgendermaf en hervorgehoben Die Warnhinweise lenken die Aufmerksamkeit des Bedieners auf eine bestimmte Prozedur oder Praktik die bei unkorrekter Ausf hrung schwere Verletzungen hervorrufen k nnen VORSICHT Die Vorsichtshinweise vor bestimmten Prozeduren machen den Bediener darauf aufmerksam daf bei Nichteinhaltung Sch den an der Anlage entstehen k nnen Die Hinweise enthalten wichtige Informationen die aus dem Text hervorgehoben werden Lagerung Beim Transport und bei der Lagerung der Controller m ssen folgende klimatische Verh ltnisse eingehalten werden a Temperatur von 20 C bis 70 C a Relative Luftfeuchtigkeit 0 95 nicht kondensierend TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 29 297 2 Gebrauchsanleitung Vor der Installation 30 297 Der Controller wird mit einer speziellen Schutzverpackung geliefert Eventuelle Transportsch den m ssen der zust ndigen rtlichen Verkaufsstelle gemeldet werden Beim Auspacken vorsichtig vorgehen damit der Controller nic
94. der der logischen Signale der Kupplungsverbinder wird mit einer WiederverschlieRbr cke geliefert 2 Stecker f r logische Signale und Pumpenmonitor plus programmierbarer Analogausgang 3 Stromausgangsstecker 24 V fir Pumpenk hlventilator Vent Valve und Messinstrument 4 Netzeingangsmodul des Controllers bestehend aus Netzsicherungen Netzstecker und EMC Filter 5 Drehschalter zum Setzen der Profibus Adresse 6 Profibus Option 7 Serieller Stecker zur Fernsteuerung 8 Pumpenstecker 34 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Gebrauchsanleitung 2 Bedienung Einschalten des Controllers Zum Einschalten des Controllers gen gt es das Netzkabel an die Steckdose anzuschlie en Pumpenstart Zum Starten der Pumpe den Verrieglungseingang best tigen und die START Taste of der vorderen Konsole des Controllers dr cken Pumpenstopp Zum Stoppen der Pumpe mu die STOP Taste an der Fronttafel gedr ckt werden Wartung Die Controller der Serie TwisTorr 84 Rack sind wartungsfrei Eventuell erforderliche Eingriffe m ssen von dazu befugtem Fachpersonal ausgef hrt werden Bei einem Defekt kann der Agilent Reparaturdienst bzw der Agilent advanced exchange service in Anspruch genommen werden der f r die Erneuerung defekter Controller sorgt WARNUNG Vor jedem Eingriff am Controller mu der Netzstecker gezogen werden Ein Controller mu unter Einhalt
95. dpadow 156 Bledne informacje 157 Az eredeti utasitas forditasa SEE Agilent Technologies 147 297 12 Podrecznik Instrukcji Informacje ogolne 148 297 Urzadzenie to jest przeznaczone do uzytku zawodowego Przed przystapieniem do korzystania uzytkownik powinien wnikliwie przesledzic zarowno ten podrecznik zawierajacy instrukcje jak rowniez kazda inna dostarczona przez Agilent informacje Agilent uchyla sie od jakiejkolwiek odpowiedzialnosci w przypadku calkowitego lub czesciowego nie przestrzegania swoich instrukcji przeznaczenia urzadzenia niezgodnie z jego przeznaczeniem i jego obslugi przez personel uprzednio nie przeszkolony naprawy urzadzenia bez odpowiedniej autoryzacji lub przeznaczenia niezgodnego z obowiazujacymi specyficznymi normami krajowymi Kontrolery z serii TwisTorr84 Rack sa przetwornikami czestotliwosci kontrolowanymi przez mikroprocesor zrealizowanymi z komponentow w stanie stalym i posiadajacymi zdolnosci samodiagnostyczne i samoochronne Dane kontrolera Operatywny frontalnie w izolacji seryjnie Sterowanie turbiny chlodzenia pompy z szybkoscia 24 Vdc Sterowanie vent valve Odczyt szybkosci pracy pompy w momencie nakazu zatrzymania odczyt szybkosci w momencie zatrzymania Odczyt cisnienia Posrednik Profibus dodatkowy Automatyczne ustawienie napiecia wejsciowego W nastepnych paragrafach zawarte sa wszystkie niezbedne informacje dotyczace gwarancji bezpieczenstwa personelu obslugu
96. e d emploi MS EE E Figure 3 Tableau arri re du Contr leur TwisTorr 84 AG Connecteur d entr e des signaux logiques le connecteur d enclenchement est dot de la barrette de r enclenchement sp ciale 2 Connecteur signaux logiques en sortie et monitorage fr quence pompe plus sortie analogique programmables 3 Connecteur de sortie alimentation 24 Vdc pour le ventilateur de refroidissement pompe vent valve et calibre 4 Module d entr e alimentation contr leur qui comprend les fusibles la prise d alimentation et le filtre ENC 5 Interrupteur rotation pour tablir l adresse du Profibus 6 Profibus facultatif 7 Connecteur s riel pour contr le distance 8 Connecteur pompe 46 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Procedures d utilisation 3 Procedures d utilisation Allumage du Contr leur Pour allumer le contr leur il suffit d introduire le c ble d alimentation dans la prise du r seau Mise en marche de la Pompe Pour faire d marrer la pompe il faut habiliter l entr e de interlock et appuyer sur la touche START du panneau avant Arr t de la Pompe Pour arr ter la pompe presser l interrupteur STOP du tableau frontal Entretien Les contr leurs de la s rie TwisTorr 84 Rack n exigent aucun entretien Toute op ration doit tre effectu
97. e installasjonen 114 297 Styreenheten leveres i en spesiell beskyttelsesemballasje Viser denne tegn p skader som kan ha oppst tt under transporten m du ta kontakt med det lokale salgskontoret N r styreenheten pakkes ut m du passe p at den ikke slippes ned eller utsettes for noen form for stat Emballasjen m ikke kastes p en ulovlig mate Alle materialer er 100 resirkulerbare og er i samsvar med EU direktiv 85 399 om milj beskyttelse E L Id dt sh Figur 1 Styreenhetens emballasje TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Instruksjon Manual 9 Installasjon Styreenheten m koples til en stromkabel med tre ledere se tabellen over deler som kan bestilles med et st psel godkjent i henhold til internasjonale standarder til sikkerhet for brukeren Bruk alltid denne stromkabelen og sett st pselet i en kontakt med passende jordledning for unng elektriske st ter og for holde seg til CE normene Inne i styreenheten utvikles hoye spenninger som kan fore til alvorlige skader eller dodsfall Kople alltid stromkabelen fra stromnettet for enhver installering eller vedlikehold av styreenheten utfores Styreenheten kan installeres p et bord eller inne i et passende stativ Uansett s m kjoleluften kunne sirkulere fritt rundt apparatet Ikke installer eller bruk styreenheten i milj er som utsettes for regn sna eller is st v aggressive ga
98. e kondensujaca Sposob polaczenia i instalowania akcesoriow jest opisany w rozdziale Technical Information TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 151 297 12 Podrecznik Instrukcji Uzytkowanie Paragraf ten zawiera podstawowe procedury operatywne Dla uzyskania dodatkowych bardziej szczegolowych informacji lub dostepu do procedur na temat polaczen lub akcesoriow skonsultowac paragraf Use znajdujacy sie w dodatku do Technical Information Przed przystapieniem do uzytkowania kontrolera wykonac wszystkie polaczenia elektryczne i pneumatyczne podlaczenie pompy konsultowac z odnosna instrukcja Dla unikniecia obrazen personelu obslugujacego urzadzenie jak rowniez uszkodzen samego urzadzenia nalezy upewnic sie szczegolnie w przypadku gdy pompa zostala ustawiona na stole czy stol jest odpowiednio stabilny Pod zadnym pozorem nie uruchamiac pompy jezeli kolnierz wejsciowy nie jest polaczony z systemem lub nie jest zamknieta kolnierzem zamykajacym W przypadku kiedy nie zostanie wykonane zadne polaczenie zewnetrzne lacznik zamykajacy J1 powinien pozostac polaczony ze swoim mostkiem Pompa wstepnej prozni i pompa TwisTorr moga byc uruchomione jednoczesnie 152 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Podrecznik Instrukcji 12 Sterowniki Wskazniki I Laczniki Ponizsze rysunki przedstawiaja panel frontalny i tylny kontrolera Dla uzyskania dokladniejsz
99. e occurred during transport contact your local sales office When unpacking the controller ensure that it is not dropped or subjected to any form of impact Do not dispose of the packing materials in an unauthorized manner The material is 100 recyclable and complies with EEC Directive 85 399 LE ss Ha Figure 1 Controller packing 198 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Instructions for Use 16 Installation WARNING The TwisTorr controller is designed for indoor use only and must be powered with 3 wire power cord see orderable parts table and plug internationally approved for users safety Use this power cord and plug in conjunction with a properly grounded power socket to avoid electrical shock and to satisfy CE reguirements High voltage developed in the controller can cause severe injury or death Before servicing the unit disconnect the input power cable The TwisTorr controller can be used as a bench unit or a rack module but it must be positioned so that free air can flow through the holes Do not install or use the controller in an environment exposed to atmospheric agents rain snow ice dust aggressive gases or in explosive environments or those with a high fire risk During operation the following environmental conditions must be respected temperature from 5 C to 45 C a relative humidity 0 95 without condensation See t
100. e werking moeten de volgende omgevingscondities aanwezig zijn a temperatuur van 5 C tot 45 C a relatieve vochtigheid 0 95 niet condenserend Voor de overige aansluitingen en de installatie van de accessoires wordt verwezen naar het hoofdstuk Technical Information TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 79 297 6 Bedrijfshandleiding Gebruik In deze paragraaf worden de voornaamste bedieningswijzen uitgelegd Voor meer informatie of procedures die aansluitingen of speciale opties betreffen wordt verwezen naar de paragraaf Use van de bijlage Technical Informations Breng alvorens de controller in gebruik te nemen alle elektrische en pneumatische aansluitingen tot stand en raadpleeg hiervoor de handleiding van de aan te sluiten pomp WAARSCHUWING Indien de pomp op een tafel is geplaatst controleren of deze stabiel staat om letsel aan personen en schade aan het apparaat te voorkomen Laat de pomp nooit werken zonder dat de ingangsflens aan het systeem is gekoppeld of de afsluitflens is gesloten De connector J1 moet met zijn jumper aangesloten blijven als geen externe aansluiting tot stand wordt gebracht De pre vacuiimpomp en de TwisTorr pomp mogen beide gelijktijdig ingeschakeld zijn 80 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Bedrijfshandleiding Bedieningsorganen Controlelampjes en Connectoren van Hieronder worden het frontpaneel
101. echnologies Concepcion Beistegui No 109 Col Del Valle C P 03100 Mexico D F Tel 52 5 523 9465 Fax 52 5 523 9472 Singapore Agilent Technologies Singapore Pte Ltd 1 Yishun Avenue 7 Singapore 768923 Tel 65 6215 8045 Fax 65 6754 0574 Toll free 1 800 2762622 vps customerserviceQagilent com Agilent Technologies Inc 2013 Printed in ITALY 11 2014 Publication Number 87 901 037 01 A Agilent Technologies Agilent Technologies Southeast Asia Agilent Technologies Sales Sdn Bhd Unit 201 Level 2 uptown 2 2 Jalan SS21 37 Damansara Uptown 47400 Petaling Jaya Selangor Malaysia Tel 603 7712 6106 Fax 603 6733 8121 Toll free 1 800 880 805 vps customerservice agilent com Taiwan Agilent Technologies Taiwan Limited 20 Kao Shuang Road Ping Chen City Tao Yuan Hsien 32450 Taiwan R O C Tel 886 3 4959004 Toll free 0800 018 768 vpw customerservice agilent com UK and Ireland Agilent Technologies UK Ltd 6 Mead Road Oxford Industrial Park Yarnton Oxford 0X5 10U UK Tel 44 0 1865 291570 Fax 44 0 1865 291571 Other Countries Agilent Technologies ltalia S p A Via F lli Varian 54 10040 Leini Torino Italy Tel 39 011 997 9111 Fax 39 011 997 9350 Toll Free 00 800 234 234 00 Customer Support amp Service NORTH AMERICA Toll Free 800 882 7426 vpl ra agilent com EUROPE Toll Free 00 800 234 234 00 vpt customercare agilent
102. ekvensomvendere som best r av komponenter med fast tilstand Styreenhetene har funksjoner for selvdiagnose og selvbeskyttelse Styreenhetens karakteristikker a Frontal virksomhet fjern seriell gangsetting av kjeleviften pa24 Vdc p pumpen a gangsetting av vent valve a Avlesing av pumpehastighet etter stoppekommando avlesing av stoppehastighet a Avlesing av trykk Grensesnitt Profibus valgfritt Automatisk innstilling av inngangsspenning De folgende avsnittene inneholder all informasjon som er nadvendig for a sikre brukeren nar utstyret er i bruk For mer detaljert bruk vises det til tillegget Technical Information TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Instruksjon Manual Denne veiledningen bruker f lgende standard protokoll 9 UN JAIRO Disse meldingene skal tiltrekke seg brukerens oppmerksomhet til en spesiell fremgangsm te eller praksis som hvis den ikke f lges kan medf re alvorlige skader Sete Denne advarselen vises foran fremgangsm ter som dersom de ikke f lges kan fore til at utstyret skades Merknadene inneholder viktig informasjon som er hentet fra teksten Lagring N r styreenhetene transporteres eller lagres m f lgende forhold v re oppfylt temperatur fra 20 C til 70 C a relativ fuktighet 0 95 uten kondens TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 113 297 9 Instruksjon Manual Forbered
103. ellen rz se s programozhat anal g kimenet sz m ra 3 Kimeneti t pcsatlakoz 24 Vdc a szivatty h t ventill tora a vent valve s az idomszer sz m ra 4 Bementei t pell t modul a vez rl sz m ra Mag ban foglalja a biztos t kokat a t pcsatlakoz t s az EMC sz r t 5 Forgat gomb a Profibus c m nek be ll t s hoz 6 Profibus opcion lis 7 Soros csatlakoz t vvez rl shez 8 Szivatty csatlakoz 142 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Felhaszn l i K zik nyv 11 Haszn lati elj r sok A vez rl bekapcsol sa A vez rl bekapcsol s hoz elegend a h l zati k belt a h l zati aljzatba illeszteni A szivatty beind t sa A szivatty beind t s hoz enged lyezni kell az interlock bemenetet s megnyomni az el lapon a START nyom gombot A szivatty le ll t sa A szivatty le ll t s hoz meg kell nyomni az el lapon tal lhat STOP nyom gombot Karbantart s A TwisTorr 84 Rack sorozat vez rl k semmif le karbantart st sem ig nyelnek Valamennyi beavatkoz st meghatalmazott szem lyzet hajthat csak v gre Meghib sod s eset n ig nybe vehet a Agilent jav t si szolg ltat sa vagy a Agilent advanced exchange service mely a meghib sodott helyett egy jav tott vez rl t biztos t VESZ LY A vez rl n val b rmely beavatkoz s v grehajt sa el tt ki kell h zni a h l zati csatlakoz t
104. emote 1 0 1 Serial 2 Front panel 3 Profibus 008 1 2 Hz 1100 1350 High Speed Value Set the high rotational speed value 120 3 2 Hz 1100 1350 Low Speed Value Set the low rotational speed value 117 280 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Input Buffer Tab 20 Input buffer Technical Information 17 OFFSET SIZE WIN BYTE BYTE UNIT RES RANGE DESCRIPTION SERIAL 0 1 V 0 100 Voltage 201 Voltage provided to the motor 1 1 C 0 100 Pump Bearing Temperature 204 Read the pump upper bearing temperature If gt 60 C the controller goes into fail status and the pump is stopped 2 1 C 0 100 Controller Power Supply Temperature 216 Read the controller power section temperature if gt 75 C the controller goes in fail status controller over temperature 3 1 C 0 100 Controller CPU Section Temperature 211 Read the controller CPU section temperature if gt 80 C the controller goes in fail controller overtemperature 4 1 0 6 Bo 3 Status 205 0 Stop 1 Waiting for interlock interlock connections on remote 1 0 connector missing 2 Ramp the pump is increasing the speed 3 Auto tuning the speed has been reduced because the gas load is higher than the Power Limit Applied 4 Braking the pump is reducing the speed using the motor 5 Normal operation the pump is at target speed 6 Fail see error code byte Input Buffer B
105. emperatura do radiador do controller superior a 60 C Aguardar at que a temperatura volte ao limite estabelecido Premer duas vezes o bot o START para reactivar a bomba TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 73 297 5 14 297 Manual de Istru es MENSAGEM DESCRI O AC O CORRECTIVA TOO HIGH Durante o funcionamento normal Verificar se o rotor da LOAD ap s a fase de accionamento a bomba pode rodar corrente absorvida pela bomba livremente Premer duas maior do que a programada vezes o bot o START para reactivar a bomba SHORT Durante o funcionamento normal Verificar as ligac es entre a CIRCUIT ap s a fase de accionamento a bomba e o controller conex o de sa da est em curto Premer duas vezes o bot o circuito START para reactivar a bomba SYSTEM A bomba parou por um sinal de Remover o cabo de OVERRIDE emerg ncia proveniente de um alimentac o do controller e contacto remoto corrigir a causa da emerg ncia Ligar novamente o cabo de alimentac o e premer duas vezes o bot o START para reactivar a bomba OVERVOLTAGE Verificou se um defeito na sec o Premer duas vezes o bot o de alimenta o do controller ou o START para reactivar a controller recebeu um sinal falso bomba Se a mensagem se reapresentar dirigir se Agilent para a manuten o POWER FAIL Avaria na se o de alimenta o da Dirigir se a Agilent para bomba do controller Manu
106. en het achterpaneel van de controller geillustreerd Voor meer informatie wordt verwezen naar het hoofdstuk Technical Information Beschrijving frontpaneel 6 Figuur 2 Frontpaneel van de Controllers TwisTorr 84 AG 1 Drukknop voor weergave op het display van de parameters cycle number cycle time en pump life 2 Drukknop voor selectie van de bedrijfswijze LOW SPEED Is alleen actief wanneer de bedrijfswijze snelheid Door de knop opnieuw in te drukken wordt LOW SPEED geinactiveerd op het frontpaneel wordt geselecteerd Door de knop een maal in te drukken draait de pomp met stand by 3 Drukknop voor weergave op het display van de parameters pump current pump temperature pump power en rotational speed Is altijd actief onafhankelijk van de gekozen bedrijfswijze Door drukknoppen 3 en 1 gelijktijdig gedurende ten minste 2 seconden in te drukken wordt een programma gestart waarmee enkele bedrijfsparameters kunnen worden geprogrammeerd 4 Drukknop voor het zenden van de sturingen START STOP RESET Is alleen actief wanneer de bedrijfswijze op het frontpaneel wordt geselecteerd Door de knop een maal in te drukken wordt de startfase geactiveerd door de knop opnieuw te bedienen wordt de pomp gestopt Als de pomp automatisch is gestopt ten gevolge van een storing moet deze knop een eerste maal worden bediend om de contro
107. ent Technologies eet oo o 0 0 2 e Agilent Technologies Vacuum Products Division Instructions for returning products Dear Customer Please follow these instructions whenever one of our products needs to be returned Complete the attached Reguest for Return form and send it to Agilent Technologies see below taking particular care to include the completed Health and Safety declaration Section No work can be started on your unit until we receive a completed copy of this form After evaluating the information Agilent Technologies will provide you with a Return Authorization RA number via email or fax as reguested Note Depending on the type of return a Purchase Order may be reguired at the time the Reguest for Return is suhmitted We will guote any necessary services evaluation repair special cleaning eg Product preparation o Remove all accessories from the core product e g inlet screens vent valves Prior to shipment and if applicable for your product drain any oils or other liguids purge or flush all gasses and wipe off any excess residue o If ordering an Advance Exchange product please use the packaging from the Advance Exchange to return the defective product o Seal the product in a plastic bag and package product carefully to avoid damage in transit You are responsible for loss or damage in transit o Include a copy of the Health and Safety Declaration in the shipping documentation on the o
108. er TwisTorr 84 AG 1 Taste f r die Anzeige der Parameter cycle number cycle time und pump life 2 Taste f r die Einstellung des Modus LOW SPEED Sie ist nur aktiv wenn der Steuermodus auf Fronttafel eingestellt ist Bei einmaligem Dr cken l uft die Pumpe in Bereitschafts Geschwindigkeit Bei nochmaligem Dricken wird der Modus LOW SPEED deaktiviert 3 Taste f r die Anzeige der Parameter pump current pump temperature pump power und rational speed Sie ist immer aktiv unabh ngig vom gew hlten Betriebsmodus Bei gemeinsamer mindestens 2 Sekunden langer Bet tigung der Tasten 3 und 1 wird ein Programm aktiviert mit dem einige Betriebsparamter programmiert werden k nnen 4 START STOP RESET Taste Sie ist nur aktiv wenn der Steuermodus auf der Fronttafel eingestellt ist Bei einmaligem Dr cken wird die Startphase aktiviert Bei nochmaligem Dr cken stoppt die Pumpe Bei automatischem Pumpenstopp durch St rung mu diese Taste ein erstes Mal zur Controller R cksetzung und dann ein zweites Mal zum Neustarten der Pumpe gedr ckt werden 5 Alphanumerisches Fl ssigkristall Display Punkt matrix 2 Zeilen mit 16 Stellen TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 33 297 2 Gebrauchsanleitung ED OE Abbildung 3 Ricktafel der Controller TwisTorr 84 AG Eingangsverbin
109. er megnyomni a START nyom gombot SHORT Norm l zem k zben az ind t si Ellen rizni az CIRCUIT f zist k vet en a kimeneti sszek ttet seket a szivatty sszek ttet s z rlatos s a vez rl k z tt A szivatty jraind t s hoz k tszer megnyomni a START nyom gombot SYSTEM A szivatty le llt egy Kih zni a vez rl h l zati OVERRIDE t v rintkez t l sz rmaz v szjel csatlakoz j t s megsz ntetni hat s ra a v szjelz s ok t jra csatlakoztatni a h l zati k belt s k tszer megnyomni a START nyom gombot a szivatty jraind t s hoz OVERVOLTAGE Meghib sod s t rt nt a vez rl A szivatty jraind t s hoz t pell t si r szegys g ben vagya k tszer megnyomni a START vez rl egy hamis jelet kapott nyom gombot Ha az zenet ism tl dik a Agilent t l karbantart si beavatkoz st k rni POWER FAIL Meghib sod s a szivatty vagy a A Agilent t l karbantart si vez rl t pell t si r szegys g ben beavatkoz st k rni TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A TwisTorr 84 FS AG Rack Controller User Manual Podrecznik Instrukcji Informacje ogolne 148 Magazynowanie 149 Przygotowanie do instalacji 150 Instalacja 151 Uzytkowanie 152 Sterowniki Wskazniki I Laczniki 153 Opis pulpitu frontalnego 153 Procedure uzytkowania 155 Zaswiecenie kontrolera 155 Uruchomienie pompy 155 Zatrzymanie pompy155 Konserwacja 155 Przetworstwo o
110. es Vacuum Products Division Reguest for Return Form Customer information Company Contact Name Address Tel Email Eguipment Product description Agilent PartNo Agilent Serial No Original Purchasing Reference Failure description Type of process for which the eguipment was used Type of return LI Non Billable JI Billable gt New PO hard copy must be submitted with this form A Exchange CI Repair Cl Upgrade Demo Calibration Evaluation Return for Credit Health and safety Substances please refer to MSDS forms Agilent will not accept delivery of any product that is exposed to radioactive biological The product has been exposed to the following substances explosive substances or dioxins PCB s without written evidence of decontamination stc VES an rat tele do tine mid Trade name Chemical name Chemical Symbol CAS Number Toxic O yes Ono Harmful O yes O no Corrosive O yes Ino Reactive O YES O NO Flammable O yes Ino Explosive O yes Ono Radioactive ves O no Biological O yes Ono Oxidizing O yes Ono Sensitizer O yes Ono Other dangerous substances ves Ono Goods preparation If you have replied YES to one of the above questions Has the product been purged O yes LIno If ves which cleaning agent method Has the product been drained from oil LJ YES LI NOT APPLICABLE I c
111. esario habilitar la entrada de interlock y pulsar el bot n START situado en el panel frontal Parada de la Bomba Para detener la bomba hay gue apretar el pulsador STOP del panel frontal Mantenimiento Los controlers de la serie TwisTorr 84 Rack no necesitan ning n mantenimiento Cualquier operaci n ha de ser efectuada por personal autorizado En caso de aver a es posible utilizar el servicio de reparaci n Agilent o del Agilent advance exchange service que permite obtener un controler regenerado en vez del averiado VV UA Antes de efectuar cualquier operaci n en el controler desenchufar el cable de alimentaci n En caso de que un controler se tenga que desguazar efectuar su eliminaci n respetando las normas nacionales espec ficas TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 59 297 4 Manual de istrucciones Eliminaci n 60 297 Significado del logotipo WEEE presente en las etiquetas El s mbolo que se indica a continuaci n es aplicado en observancia de la directiva CE denominada WEEE Este s mbolo v lido s lo para los pa ses miembros de la Comunidad Europea indica que el producto sobre el cual ha sido aplicado NO debe ser eliminado junto con los residuos comunes sean stos dom sticos o industriales y que por el contrario deber ser sometido a un procedimiento de recogida diferenciada Por lo tanto se invita al usuario final a ponerse en contacto con el proveedor del
112. g command the SLAVE will respond transmitting a string with the same structure of the MESSAGE Using the RS 485 interface the message structure remains identical to the one used for the RS 232 interface the only difference being that the value assigned to the ADDRESS lt ADDR gt TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 237 297 17 Technical Information The controller can answers with the following response types Tab 14 Response Type Response Response Description Length Value Logic 1 byte after a read instruction of a logic window Numeric 6 bytes after a read instruction of a numeric window Alphanumeric 10 bytes after a read instruction of an alphanumeric window ACK 1 byte 0x6 the command execution has been successfully completed NACK 1 byte 0x15 the command execution has been failed Unknown Window 1 byte 0x32 the specified window in the command is not a valid window Data Type Error 1 byte 0x33 the data type specified in the command Logic Numeric or Alphanumeric is not accorded with the specified Window Out of Range 1 byte 0x34 the value expressed during a write command is out of the range value of the specified window Win Disabled 1 byte 0x35 the specified window is Read Only or temporarily disabled for example you can t write the Soft Start when the Pump is running 238 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037
113. gen f r pumpen tilsluttes ADVARSEL Sorg for at pumpen st r fast hvis den er installeret p et bord Dette er for at forebygge skader p apparatet og personer Start aldrig pumpen hvis pumpetillobet ikke er tilsluttet systemet eller er blokeret Afbryderkontakten J1 skal forblive tilsluttet med aktuel bro n r der ikke udfores eksterne tilslutninger Forvakuumpumpen og TwisTorr pumpen skal fungere samtidigt 92 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Istruktionsbog 7 Indikatorer og Kontakter p Styreenheden Nedenfor vises styreenhedens front og bagpanel For yderligere information henvises til bilag Technical Information Beskrivelse af frontpanel 1 VACUUM TECHNOLOGIES 3 COUNTERS MEASURES increase next menu LOW SPEED TwisTorr 84 FS AG Figur 2 Frontpanelet p Styreenheden TwisTorr 84 AG 1 Trykknap til at hente cycle number cycle time og pump lift frem p displayet 2 Trykknap til installering af LOW SPEED driftvalg Trykknappen fungerer kun n r der v lges fra frontpanelet Tryk p knappen en gang for at f pumpen til at rotere med standby hastighed Tryk p knappen igen for at g ud af LOW SPEED driften 3 Trykknap til at hente pump current pump temperature pump power og rotational speed frem p displayet Trykknappen fungerer altid uanset den valg
114. gilent cannot guarantee compliance with FCC regulations for radiated emissions unless all external wiring is shielded with the shield being terminated to the metal shroud on the 0 subconnector The cable should be secured to the connector with screws Serial Communication Descriptions This unit can comunicate by two different protocol protocol old system letter Window protocol new system These two protocols can be used as well with 232 or 485 media Please use Window protocol for new development TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 229 297 17 Technical Information Letter Protocol Description 230 297 The default protocol is Window Communication format 8 data bit a no parity 1 stop bit The baud rate is programmable via front panel from 600 to 9600 baud The controller is factory set for 9600 baud operation Communication protocol Host Master Controller Slave The communication is performed in the following way Host Controller Request CRC Answer CRC Request is an ASCII character identifying the action that must be performed by the controller or the requested information Allowed ASCII characters JA z START a B lt STOP C Low Speed ON D Low Speed OFF a E Request for operational parameters a JE lt Pump times zeroing TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Tec
115. gkeit 0 95 nicht kondensierend TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 31 297 2 Gebrauchsanleitung Gebrauch In diesem Kapitel sind die wichtigsten Betriebsvorg nge aufgef hrt F r weitere Hinweise bez glich Anschl sse und Montage des bestellbaren Zubeh rs siehe Kapitel Use im Anhang zu Technical Information Vor Benutzung des Controllers s mtliche elektrischen und pneumatischen Anschl sse ausf hren und die Betriebsanleitung der angeschlossenen Pumpe durchlesen Steht die Pumpe auf einem Tisch muB auf den stabilen Stand geachtet werden da sonst die Gefahr von Personen und Ger tesch den besteht Die Pumpe nie einschalten wenn der Eingangsflansch nicht am System angeschlossen bzw nicht mit dem Schlief flansch abgedeckt ist Der WiederverschlieR Verbinder J1 mu mit seiner Br cke angeschlossen bleiben wenn kein externer Anschlu erfolgt Die Vorvakuumpumpe und die TwisTorr Pumpe k nnen gleichzeitig eingeschaltet werden 32 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Gebrauchsanleitung 2 Steuerungen Anzeigen und Verbinder des Controllers Der folgende Abschnitt beschreibt die vordere und hintere Konsole des Controllers F r weitere Einzelheiten siehe Technical Information Fronttafel der Controller 5 1 3 2 4 Abbildung 2 Fronttafel der Controll
116. gnal auf dem Verbinder P1 ist wegen der KurzschluR unterbrechung zwischen Pin 3 und Pin 8 des Verbinders K1 oder wegen der ffnung des externen Interlock Signals aktiv Den KurzschluB zwischen Pin 3 und Pin 8 des Verbinders P1 riicksetzen oder das externe Interlock Signal schlieRen PUMP OVERTEMP Die Temperatur des oberen Lagers bzw der Pumpe hat 60 C berschritten Warten bis die Temperatur unter den Schwellenwert gesunken ist Die Pumpe durch zweimalige Bet tigung der START Taste neustarten CONTROLLER OVERTEMP Die Temperatur des Controllers hat 70 C berschritten Oder Die Temperatur des Kontroller k hlk rpers ist ber 60 C Warten bis die Temperatur unter den Schwellenwert gesunken ist Die Pumpe durch zweimalige Bet tigung der START Taste neustarten TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 37 297 2 38 297 Gebrauchsanleitung MELDUNG BESCHREIBUNG BEHEBUNG TOO HIGH LOAD Die Pumpen ist stromaufnahme gr Rer als die vorgesehene Sicherstellen da der Pumpenrotor ungehindert drehen kann Die Pumpe durch zweimalige Bet tigung der START Taste neustarten SHORT CIRCUIT W hrend des Normalbetriebs nach der Startphase erfolgt ein Kurzschlu der Ausgangsverbindung Die Verbindung zwischen Pumpe und Controller pr fen Die Pumpe durch zweimalige Bet tigung der START Taste neustarten SYSTEM OVERRIDE D
117. gu ncia controlados por um microprocessador realizados com componentes em estado s lido e com capacidade de autodiagn stico e autoprotecc o Caracter sticas do controller Operatividade frontal remota serial Pilotagem em 24 Vdc da ventoinha de resfriamento bomba a Pilotagem vent valve a Leitura velocidade bomba seguindo ao comando de paragem leitura velocidade de paragem a Leitura da press o a Interface Profibus opcional Imposta o autom tica tens o de entrada Nos par grafos seguintes est o descritas todas as informa es necess rias para garantir a seguran a do operador durante o uso da aparelhagem Informa es pormenorizadas s o fornecidas no ap ndice Technical Information TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Manual de Istru es 5 Este manual utiliza as seguintes conven es ATEN AO As mensagens de aten o chamam a aten o do operador para um procedimento ou uma pr tica especifica que se n o efectuada correctamente pode provocar graves les es pessoais CUIDADO As mensagens de cuidado s o visualizadas antes de procedimentos que se n o observados podem causar danos aparelhagem As notas cont m informa es importantes destacadas do texto Armazenagem Durante o transporte e a armazenagem dos controllers devem ser satisfeitas as seguintes condi es ambientais a temperatura de 20 C a 70 C humidade relat
118. ha recibido una se al espurio Apretar dos veces el pulsador START para volver a poner en marcha la bomba Si el mensaje se vuelve a presentar dirigirse a Agilent para el mantenimiento POWER FAIL Aver a en la secci n de alimentaci n de la bomba del controler Ponerse en contacto con Agilent para el Mantenimiento 62 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A TwisTorr 84 FS AG Rack Controller User Manual Manual de Istruc es Informac es gerais 64 Armazenagem 65 Prepara o para a instala o 66 Instala o 67 Utilizac o 68 Comandos Indicadores e Conectores Descric o painel frontal 69 Procedimentos de uso 71 Acendimento do Controller 71 Activac o da bomba 71 Paragem da bomba71 Manutenc o 71 Eliminac o 72 Mensagens de erro 73 Tradu o das instru es originais EM Agilent Technologies 69 63 297 5 Manual de Istru es Informac es gerais 64 297 Esta aparelhagem destina se ao uso profissional O utilizador deve ler atentamente o presente manual de instru es e todas as informa es adicionais fornecidas pela Agilent antes de utilizar a aparelhagem A Agilent n o se responsabiliza pela inobservancia total ou parcial das instruc es pelo uso indevido por parte de pessoas n o treinadas por operac es n o autorizadas ou pelo uso contr rio s normas nacionais espec ficas Os controllers da s rie TwisTorr 84 Rack s o conversores de fre
119. he appendix Technical Information for detailed Information about the above mentioned and the other connections and about the options installation TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 199 297 16 Instructions for Use Use This paragraph describes the fundamental operating procedures Detailed information and operating procedures that envolve optional connection or option are supplied in the paragraph USE of the appendix Technical Information Make all vacuum manifold and electrical connections and refer to TwisTorr pump instruction manual before operating the TwisTorr controller To avoid injury to personnel and damage to the equipment if the pump is laying on a table make sure it is steady Never operate the TwisTorr pump if the pump inlet is not connected to the system or blanked off The input signal J1 connector should be left in position including the shipping links if no external connections are made The forepump and TwisTorr pump can be switched on at the same time 200 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Instructions for Use 16 Controls Indicators and Connectors The following paragraph illustrates the Controller control panel and interconnection panel More details are contained in the appendix Technical Information Front Panel Description 1 VACUUM TECHNOLOGIES 3 COUNTERS MEASURE
120. her the pump is cooled with water or not The controller limits the power supplied to the pump according to this setting TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Technical Information 17 ACTIVE STOP enables YES or disables NO active braking STOP SPEED READING enables YES or disables NO the pump rotational frequency reading function also during the slowing phase that follows a stop command Input Output Menu This menu contains parameters that determine the operating mode of the inputs and outputs of the controller IMPUT OPTPUT la gt START MODE gt START INTERLOCK kosc 4 START STOP LEVEL START STOP EDGE Y INTERLOCK TYPE gt CONTINUOUS A IMPULSIVE y ANALOG OUT TYPE t FREQUENCY A POWER CURRENT PRESSURE Y START OUT MODE gt RUNNING A STARTING y SPEED DISPLAY amp gt KRPM x E Hz Y LCD CONTRAST k gt 0 sica Sicilie 1 i I 7 Flow 3 6 Figure 40 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 263 297 17 Technical Information 264 297 START MODE Permits selection of one of the three types of functioning of the START STOP and INTERLOCK inputs START INTERLOCK The pump is started
121. hnical Information 17 G Parameters reading H Parameters writing I Request for operating status J Request for numerical reading K Request for counters reading CRC corresponds to the sum with inverted sign of all the preceding bytes e g the START command A in ASCII code 41 inverted it will be FF 1 41 BF Tab 6 CHARACTER ASCII CONVERTED ASCII FOR CRC CALCULATION A 41h CRC BFh B 42h CRC BEh c 43h CRC BDh D 44h CRC BCh E 45h CRC BBh F 46h CRC BAh G 47h CRC 89h H 48h 49h CRC B7h J 4Ah CRC B6h TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 231 297 17 Technical Information CHARACTER ASCII CONVERTED ASCII FOR CRC CALCULATION K 4Bh CRC B5h ACK 06h CRC FAh NACK 15h CRC EBh Answer after a request from the host the Controller will answer in one of the following ways ACK NACK Message When the Request is A B C D F the Controller will Answer the ACK or NACK When the Request is E the Answer will contain the complete set of the following parameters Tab 7 BYTES MEANING 1 MSB LSB XXX 0 STOP 1 WAITING INTERLOCK 2 STARTING 3 NORMAL OPERATION 4 5 HIGH LOAD 6 FAILURE 7 APPROACHING LOW SPEED 2 5 Cycle Time 6 9 Pump Life 10 11 Pump Temperature 12 Current 232 297 TwisTorr 84 FS AG Rack Contr
122. ht f llt oder St f en ausgesetzt wird Das Verpackungsmaterial mu korrekt entsorgt werden Es ist vollst ndig recyclebar und entspricht der EG Richtlinie 85 399 f r Umweltschutz f L JE Zio dii ji J Abbildung 1 Verpackung der Controller TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Gebrauchsanleitung 2 Installation WARNUNG Der TwisTorr Controller muss mit einem dreiadrigen Netzkabel und dem international zugelassenen Stecker angeschlossen werden Es sollte immer dieses Netzkabel benutzt werden das an eine korrekt geerdete Steckdose anzuschlieRen ist um den CE Richtlinien zu entsprechen und Stromschl ge zu vermeiden Im Inneren des Controllers entstehen hohe Spannungen die schwere Verletzungen verursachen und lebensgef hrlich sein k nnen Vor jedem Montage bzw Wartungseingriff muss deshalb der Netzstecker gezogen werden Der Controller kann auf einen Tisch oder ein Gestell montiert werden In beiden F llen mu auf die ungehinderte Zirkulation der K hlluft im Bereich des Ger ts geachtet werden Der Controller darf nicht in Umgebungen installiert u o benutzt werden die Witterungseinfl ssen Regen Frost Schnee Staub und aggressiven Gasen ausgesetzt sind und in denen Explosions und erh hte Brandgefahr besteht Beim Betrieb m ssen folgende Umgebungsbedingungen eingehalten werden Temperatur von 5 C bis 45 C a Relative Luftfeuchti
123. ia E Vo vn tri controller sa vytv ra vysok nap tie ktor m e sp sobi v ne kody alebo smr Pred ak mko vek konom t kaj ceho sa in tal cie alebo dr by controller a nezabudnite vytiahnu z str ku z elektrickej z suvky Controller m e by in talovan na pracovnom stole alebo vo vn tri track V ka dom pr pade je potrebn aby chladiaci vzduch mohol vo ne kr i okolo pr stroja Controller nepou vajte a nein talujte v prostred vystavenom atmosferick m vplyvom d mr z sneh prachu agres vnym plynom a v prostred s vysok m rizikom po iaru Po as chodu je d le it aby boli re pektovan tieto podmienky prostredia teplota od 5 C do 45 C relativna vlhkos 0 95 nekondenzovan Pre ostatn napojenia a in tal ciu zvolite n ho pr slu enstva vi as Technical Information TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 175 297 14 N vod na Obsluhu Pou itie V tomto odstavci s uveden hlavn operat vne postupy Pre ostatn detaily a pre postupy ktor sa vz ahuj na napojenia alebo na zvolen pr slu enstvo postupujte pod a asti Use v dodatku Technical Information Pred pou it m Controller preve te v etky potrebn elektrick a pneumatick napojenia a ria te sa pod a n vodu napojen ho arpadla NEBEZPE IE Aby ste sa vyhli osobn mu nebezpe i
124. ical Information 17 ANALOG OUT TYPE permits selection of the type of signal to be sent to the programmable analogue output One of the following signals can be selected FREQUENCY the drive frequency of the pump is shown POWER the power supplied to the pump is shown TEMPERATURE the temperature of the pump is shown PRESSURE the pressure read by the gauge is shown START OUT MODE Selects the operating mode of the START output Possible options RUNNING the output is active when the pump is driven STARTING the output is active only during acceleration ramp up SPEED OUT MODE KRPM Hz permits selection of the unit of measurement of the speed of rotation shown on the display of the controller This setting acts only on the measurement shown on the display Possible options KRPM Hz LCD CONTRAST TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 265 297 17 Technical Information Setpoint R1 and Setpoint R2 Submenus This submenu contains the settings relating to the output with relay R1 and R2 if it is connected a gauge it will present also the settings for the set point 3 i I I SET POINT R1 R2 SETTING a gt R1 R2 TYPE ff gt FREQUENCY E 1 rr A I y POWER E TIME E NORMAL E PRESSURE v R1 R2 SET VALUE 0000 ae vue Y R1 R2 HYSTERESYSI
125. idad de parada Lectura de la presi n a Interfaz Profibus opcional Configuraci n autom tica tensi n de entrada En los apartados siguientes se facilita toda la informaci n necesaria para garantizar la seguridad del operador durante el uso del equipo Una informaci n m s detallada se facilita en el Suplemento Technical Information TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Manual de istrucciones 4 Este manual utiliza los s mbolos convencionales siguientes EUA MANIM Los mensajes de advertencia atraen la atenci n del operador sobre un procedimiento o una operaci n especifica que al no realizarse correctamente podr a provocar graves lesiones personales Ta 81035 Los mensajes de atenci n se visualizan antes de procedimientos que al no respetarse podr an provocar da os al equipo Las notas contienen informaci n importante extra da del texto Almacenamiento Durante el transporte y el almacenamiento de los controlers se deber cumplir con las condiciones ambientales siguientes a temperatura de 20 C a 70 C humedad relativa O 95 no condensadora TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 53 297 4 Manual de istrucciones Preparaci n para la instalaci n El controler se suministra en un embalaje de protecci n especial si se observan se ales de da os que podr an haberse producido durante el transporte ponerse en contacto
126. ie Pumpe wurde durch ein von einem entfernten Kontakt kommendes Notsignal gestoppt Das Netzkabel des Controllers ausstecken und die St rungsursache beheben Das Netzkabel wieder anschlieRen und die Pumpe durch zweimalige Bet tigung der START Taste neustarten OVERVOLTAGE Defekt im Versorgungsbereich des Controllers bzw der Controller hat ein falsches Signal erhalten Die Pumpe durch zweimalige Bet tigung der START Taste neustar ten Erscheint die Meldung wieder sollte der Agilent Wartungs dienst gerufen werden POWER FAIL Defekt im Pumpenstromkreis des Controllers Agilent f r Wartung kontaktieren TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A TwisTorr 84 FS AG Rack Controller User Manual 3 Mode d emploi Indications generales 40 Emmagasinage 41 Preparation pour l installation 42 Installation 43 Utilisation 44 Commandes Indicateurs et Connecteurs 45 Description du Tableau avant 45 Procedures d utilisation 47 Allumage du Contr leur 47 Mise en marche de la Pompe 47 Arr t de la Pompe 47 Entretien 47 Mise au rebut 48 Messages d erreur 49 Traduction de la mode d emploi originale kai Agilent Technologies 39 297 3 Mode d emploi Indications generales 40 297 Cet appareillage a t concu en vue d une utilisation professionnelle Il est conseille a utilisateur de lire attentivement cette notice instructions ainsi que toute autre indication suppl mentaire fo
127. if the START STOP input is activated and is stopped if the START STOP input is de activated The interlock input must be constantly active INTERLOCK TYPE parameter continuous or may be active only at the time of starting INTERLOCK TYPE parameter impulsive START STOP LEVEL The START STOP input acts as only START command active on the level The INTERLOCK input acts as STOP command active on the level In the case of concurrent activation of the two inputs the STOP command takes priority START STOP EDGE The START STOP input acts as START command active on the edge The INTERLOCK input acts as STOP command active on the edge INTERLOCK TYPE This parameter is displayed only when the previous parameter START MODE is equal to START INTERLOCK and permits selection of one of the following two operating modes of the INTERLOCK input CONTINUOUS the INTERLOCK input must be active continuously so that the pump can be driven by the controller If with the controller in start the input INTERLOCK is de activated the controller switches to WAITING INTERLOCK status and interrupts driving of the pump IMPULSIVE it is sufficient for the input to be active when the START command is sent to the pump Subsequently the input can also be de activated If the interlock is not active when the pump is started the controller switches too WAITING INTERLOCK status TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Techn
128. igin ln ho n vodu RE Agilent Technologies 159 297 13 Navod k Pou it V eobecn informace Tento p stroj je ur en pro profesion ln pot ebu U ivatel si mus p ed pou it m tuto p ru ku velmi pozorn p e st ale i ka dou dal aktualizaci kterou podnik bude p ed vat V d sledku nedostate n ho i ste n nespr vn ho pou it nebo v p pad chyb nevy kolen ho person lu i neopr vn n ch z sah a neodpov daj c ch specifick m st tn m norm m Agilent nep ij m a nenese dnou zodpov dnost Kontrol ry s rieTwisTorr 84 Rack jsou frekven n mi konvertory jsou kontrolovan mikroprocesorem a skl daj se z pevn ch komponent s autodiagnostickou a samoochrannou schopnost Charakteristiky kontrol ru eln operativnost d lkov seri ln a Pilot z o 24 Vdc ochlazovac lopatky erpadla Pilot vent valve ten rychlosti erpadla po p kazu zastaven ten rychlosti zastaven ten tlaku Rozhran Profibus op n Automatick nastaven vstupn ho nap t V n sleduj c ch odstavc ch jsou uvedeny ve ker nutn informace t kaj c se oper tora a bezpe nostn ch podm nek b hem provozu p stroje Detailn informace se nach zej v dodatku Technical Information 160 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A N vod k Pou it 13 Tato pr ru ka pou v n sledujici ozna
129. ikana tulevat seuraavat ymp rist vaatimukset olla t ytettyin a l mp tila 20 C ja 70 C asteen v lill a suhteellinen kosteus 0 95 ilman lauhdetta TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 125 297 10 Ohjekasikirja Valmistelut asennusta varten Valvoja toimitetaan erityisess suojaavassa pakkauksessa Mik li havaitsette mahdollisesti kuljetuksen aikana tapahtuneita vaurioita ottakaa yhteys paikalliseen myyntitoimistoon Pakkauksen purkamisen yhteydess huolehtikaa ett valvoja ei p se putoamaan ja v ltt k sen joutumista iskujen kohteeksi lk j tt k pakkausta ymp rist n Materiaali voidaan kokonaisuudessaan kierr tt ja se vastaa EU n 85 399 direktiivi ymp rist n suojelusta Kuva 1 Valvojan pakkaus 126 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Asennus Ohjekasikirja 10 LUKIEN K ytt j n turvallisuuden vuoksi valvojan virranottoon on k ytett v kolmijohtimista s hk kaapelia ks tilattavien osien taulukko jonka pistoke on kansainv lisesti hyv ksytty tyyppi K yt aina t t kaapelia ja kiinnit pistoke asianmukaisesti maadoitettuun pistorasiaan s hk iskujen v ltt miseksi ja CE vaatimusten noudattamiseksi Valvojan sis ll muodostuu korkeaj nnitett joka voi aiheuttaa vakavia vammoja tai jopa kuoleman Ennen mihink n asennus tai huoltotoimenpiteisiin ryhtymist val
130. ingsdel har uppst tt eller styrenheten har f tt en falsk signal Tryck tv g nger p knappen START f r att starta om pumpen Om meddelandet visas igen ta kontakt med Agilent f r n dv ndigt underh ll POWER FAIL Fel i sektionen f r str mtillf rsel till pumpen styrenheten Ta kontakt med Agilent f r Underh ll TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A TwisTorr 84 FS AG Rack Controller User Manual 9 Instruksjon Manual Generell informasjon 112 Lagring 113 Forberede installasjonen 114 Installasjon 115 Bruk 116 Indikatorer og Kontakter p Styreenheten 117 Beskrivelse av frontpanelet 117 Instruksjoner for bruk 119 Starte styreenheten 119 Starte pumpen119 Stoppe pumpen 119 Vedlikehold 119 Eliminering 120 Feilmeldinger 121 Oversetting av den opprinnelige samsvarserkl ringen RE Agilent Technologies 111 297 9 Instruksjon Manual Generell informasjon 112 297 Dette utstyret er beregnet til bruk av profesjonelle brukere Brukeren b r lese denne brukerveiledningen og all annen informasjon fra Agilent for utstyret tas i bruk Agilent kan ikke holdes ansvarlig for hendelser som skjer p grunn av manglende oppfalging selv delvis av disse instruksjonene feilaktig bruk av utrenet personell ikke godkjente endringer av utstyret eller handlinger som p noen m te er i strid med nasjonale bestemmelser Styreenhetene i TwisTorr 84 Rack serien er mikroprosessor styrte fr
131. itivo seja este o fabricante ou um revendedor para encaminhar o processo de recolha e eliminac o ap s a oportuna verifica o dos termos e condi es do contrato de venda TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Mensagens de erro Manual de Istru es 5 Em alguns casos de defeitos os circuitos de autodiagn stico do controller apresentam mensagens de erro relacionadas na tabela abaixo Tab 1 MENSAGEM DESCRI O AC O CORRECTIVA CHECK CONNECTION TO PUMP Mau funcionamento na liga o entre a bomba e o controller Ou A bomba possui temperatura inferior a 0 C Verificar se o cabo de liga o entre a bomba e o controller est bem fixado em ambas as extremidades e n o est interrompido Premer duas vezes o bot o START para reactivar a bomba WAITING INTERLOCK activado o sinal de interlock existente no conector P1 devido interrup o do curto circuito entre o pin 3 e o pin 8 do conector J1 ou devido abertura do sinal de interlock externo Restabelecer o curto circuito entre o pin 3 e o pin 8 do conector P1 ou fechar o sinal de interlock externo PUMP OVERTEMP A temperatura do rolamento superior ou da bomba superou os 60 C Aguardar at que a temperatura volte ao limite estabelecido Premer duas vezes o bot o START para reactivar a bomba CONTROLLER OVERTEMP A temperatura do controller superou os 70 C Ou t
132. iva 0 95 n o condensante TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 65 297 5 Manual de Istru es Preparac o para a instalac o 66 297 O controller fornecido numa embalagem protectora especial se apresentar sinais de danos que poderiam verificar se durante o transporte entrar em contacto com o escrit rio de vendas local Durante a retirada da embalagem tomar muito cuidado para n o deixar cair o controller e para n o submet lo a choques N o depositar a embalagem no meio ambiente O material completamente recicl vel e responde a directriz CEE 85 399 para a protec o do meio ambiente Figura 1 Embalagem dos controllers TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Manual de Istru es 5 Instalac o PH O controller deve ser alimentado mediante um cabo de alimenta o de tr s fios ver tabela das partes orden veis com uma tomada de tipo aprovado a n vel internacional com a finalidade de seguran a do usu rio Utilizar sempre este cabo de alimenta o e inserir a tomada com uma adequada liga o de terra para evitar descargas el ctricas e para respeitar as normativas CE No interior do controller desenvolvem se altas tens es que podem provocar graves danos ou a morte Antes de efectuar qualquer opera o de instala o ou manuten o do controller desligar a tomada de alimenta o O controller pode ser instalado numa me
133. ja P ali zaprite signal zunanjega interlocka PUMP OVERTEMP Temperatura gornjega le i a ali rpalke je presegla i 60 C Po akajte da se temperatura vrne pod normalnim vrednostnim pragom Pritisnite dvakrat tipko START za ponoven zagon rpalke CONTROLLER OVERTEMP Temperatura controllera je presegla 70 C Ali Temperatura controllerskega radiatorja je vi ja od 60 C Po akajte da se temperatura vrne pod normalnim vrednostnim pragom Dvakrat pritisnite tipko START za ponoven zagon rpalke TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 193 297 15 194 297 Priro nik za Navodila OBVESTILO OPIS POPRAVA TOO HIGH LOAD Tok ki ga rpalka prejme je ve ji od programiranega Preverite da lahko rotor rpalke prosto vrti Dvakrat pritisnite tipko START za ponoven zagon rpalke SHORT CIRCUIT Med navadnim delovanjem po zagonu je priklopitev na izhodu v kratkem stiku Preverite priklju ke rpalke in controllera Dvakrat pritisnite tipko START za ponoven zagon rpalke SYSTEM OVERRIDE Delovanje rpalke je zaustavil signal zasilnosti iz oddaljenega kontakta Izklopite napajalni kabel controllera in popravite napako ki se je pojavila s signalom zasile Ponovno priklju ite napajalni kabel in pritisnite dvakrat tipko START za ponoven zagon rpalke OVERVOLTAGE Kvar v oddelku za napajanje controllera ali je co
134. jacego urzadzenie Bardziej szczegolowe informacje sa zawarte w dodatku do Technical Information TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Podrecznik Instrukcji 12 Podrecznik ten opiera sie na nastepujacych konwencjach Sygnaly ostrzegajace o zagrozeniu powinny zwrocic uwage operatora na odpowiednia specyficzna procedure ktora jezeli nie jest przestrzegana w sposob prawidlowy moze przyczynic sie do powaznych obrazen osoby obslugujacej Sygnaly wzrokowe ukazujace sie przed procedura jezeli zostana zlekcewazone moga spowodowac uszkodzenia urzadzenia Przypisy zawieraja najwazniejsze informacje wyciagniete z tekstu Magazynowanie Kontrolery podczas transportu i przechowywania w magazynie powinny miec nastepujace warunki otoczenia temperatura od 20 C do 70 C a wilgotnosc wzgledna od 0 95 nie kondensujaca TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 149 297 12 Podrecznik Instrukcji Przygotowanie do instalacji Kontroler zostaje dostarczony w specjalnym ochronnym opakowaniu jezeli opakowanie prezentuje jakiekolwiek uszkodzenia ktore moglyby powstac podczas transportu wowczas nalezy niezwlocznie powiadomic najblizszy lokalny punkt sprzedazy Podczas operacji rozpakowywania nalezy zachowac specjalna ostroznosc zeby nie spowodowac upadku kontrolera lub nie narazic na uderzenia Nie wyrzucac opakowania poniewaz jest ono calkowicie rycyklowal
135. k alakulnak ki melyek s lyos k rokat vagy hal lt okozhatnak A vez rl b rmely telep t si vagy karbantart si m velet nek megkezd se el tt ki kell h zni a h l zati csatlakoz t A vez rl telep t sre ker lhet egy asztalon vagy egy megfelel rack belsej ben Minden esetben sz ks ges azonban hogy a h t leveg szabadon ramolhasson a berendez s belsej ben A vez rl t nem szabad l gk ri hat soknak es fagy h kitett poros mar hat s g zt tartalmaz robban s vagy fokozottan t zvesz lyes k rnyezetben telep teni vagy haszn lni zem k zben az al bbi k rnyezeti felt teleket kell biztos tani h m rs klet 5 C s 45 C k z tt a relativ nedvess gtartalom 0 95 nem lecsap d A t bbi sszek t ssel s az opcion lis kieg sz t felszerel sek telep t s vel kapcsolatosan l sd a Technical Information c m alfejezetet TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 139 297 11 Felhaszn l i K zik nyv Haszn lat Ebben a szakaszban a fontosabb m k d si elj r sok ker lnek ismertet sre Tov bbi r szletek s az sszek t seket vagy az opcion lis elemeket rint elj r sok tal lhat k a Technical Information mell klet Use c m szakasz ban A vez rl haszn lata el tt valamennyi elektromos s pneumatikus sszek ttet st l tre kell hozni s figyelembe kell venni a csatlakoztatott szivatty k zik
136. kendt stik efter internationale standarder Anvend udelukkende det medleverede stromkabel I henhold til EU reglerne m stikket kun tilsluttes et vegudtag med fungerende jordtilslutning for at undg elektriske stad Spaending frembragt i styreenheden kan n hoje verdier og for rsage stor skade og dodsfald Frakobel altid stromkablet inden der udfores installations eller vedligeholdelsesarbejde p styreenheden Styreenheden kan installeres p et bord eller et velegnet stativ begge tilf lde skal der vere plads nok til at luft kan cirkulerer frit omkring apparatet Install r og anvend ikke styreenheden i miljger der uds ttes for pavirkninger fra atmosfeeren regn sne is damp aggressive gasser og ligeledes ikke i eksplosivt eller brandfarligt milj F lgende krav til omgivelsesforholdene g lder ved drift temperatur fra 5 C til 45 C a relativ luftfugtighed O 95 ikke kondenserende For vrige tilslutninger og installation af tilbeh r henvises til afsnittet Technical Information TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 91 297 7 Istruktionsbog Anvendelse Dette afsnit beskriver de vigtigste driftsprocedurer For en detaljeret beskrivelse samt procedurer der involverer tilslutninger eller tilbehgr henvises til afsnittet Use i bilag Technical Information Inden styreenheden anvendes bor samtlige elektriske og pneumatiske tilslutninger udfores L s brugsanvisnin
137. koelventilator van de pomp a Sturing vent valve Lezen snelheid pomp na stopcommando lezen stopsnelheid Lezen van de druk a Interface Profibus optie Automatische instelling ingangsspanning In de volgende paragrafen is alle informatie vermeld om de veiligheid van de operator tijdens het gebruik van de apparatuur te verzekeren Gedetailleerde informatie is te vinden in de bijlage Technical information TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Bedrijfshandleiding 6 Deze handleiding hanteert de volgende symbolen A S IN Bij dit symbool staat tekst die de aandacht van de operator vestigt op een speciale procedure of methode die indien niet correct uitgevoerd ernstig lichamelijk letsel kan veroorzaken Mode Te Bij dit symbool staat tekst met procedures die indien niet opgevolgd schade aan apparatuur kunnen veroorzaken De opmerkingen bevatten belangrijke informatie die uit de tekst is gelicht Opslag Tijdens het transport en de opslag van de controllers moeten de volgende omgevingscondities aanwezig zijn a temperatuur van 20 C tot 70 C a relatieve vochtigheid 0 95 niet condenserend TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 71 291 6 Bedrijfshandleiding Voorbereiding voor installatie De controller wordt in een speciale beschermende verpakking geleverd als er schade wordt geconstateerd die tijdens het transport veroorzaakt zou kunnen
138. kontakt str mkabel og finn frem til rsaken til n dstoppen Kople deretter maskinen til str mnettet igjen Trykk to ganger p knappen START for starte pumpen OVERVOLTAGE Det har oppst tt en feil i Trykk to ganger p knappen styreenhetens matedel eller s har START for starte pumpen styreenheten f tt et falskt signal igjen Vises feilmeldingen om igjen m du ta kontakt med Agilent for n dvendig vedlikehold POWER FAIL Feil p matesektoren p pumpen Henvend deg til Agilent for p styreenheten vedlikehold TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A TwisTorr 84 FS AG Rack Controller User Manual 10 Ohjek sikirja Yleisi tietoja 124 Varastointi 125 Valmistelut asennusta varten 126 Asennus 127 K ytt 128 Valvojan S timet Osoittimet ja Liittimet 129 Etupaneelin kuvaus 129 K ytt toimenpiteet 131 Valvojan k ynnistys 131 Pumpun k ynnistys 131 Pumpun pys ytt minen 131 Huolto 131 H vitt minen 132 Vianetsint 133 Alkuper isen ohjeiden k nn s Ee Agilent Technologies 123 297 10 Ohjek sikirja Yleisi tietoja T m laite on tarkoitettu ammattimaiseen k ytt n Ennen laitteen k ytt nottoa k ytt j n tulee lukea huolellisesti mukana seuraava k ytt ohje sek kaikki muut Agilentin toimittamat lis tiedot Agilent ei vastaa seurauksista jotka johtuvat laitteen k ytt ohjeiden t ydellisest tai osittaisesta laiminly mise
139. l speed of the pump 15 Hz 0 1500 Target Freguency 120 Read the target rotational speed 17 0 65536 Cycle Number 301 Number of cycles start and stop done by the pump 19 min 0 65536 Last Cycle Time 300 How long the last cycle lasted 21 h 0 65536 Pump Life 302 Total pump running time 23 mBar Torr Pressure Reading 224 Pa Reports the pressure reading in the pressure unit selected by Par Buff Offset 20 Bs TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 283 297 17 Technical Information Diagnostic Management In addition to the ProfiBus six byte standard diagnostic the interface provides both user diagnostic and static diagnostics functions The standard diagnostic management is fully compliant with the ProfiBus specification During the start up phase after power on the first byte in the user diagnostic area can assume values different from zero This byte has the following meaning a Bit0 I controller not responds RS485 link broken a Bit I 1 controller not identified not compatible with the ProfiBus gateway a Bit 2 1 first loop of requests not ended values in the input data are not fully coherent yet So if the first byte is egual to 0 the interface is working properly otherwise there is a problem 284 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Technical Information 17 Each nibble in the bytes following the interface status byte represents the s
140. le in any technical data Trademarks Windows and MS Windows are U S registered trademarks of Microsoft Corporation Safety Notices A CAUTION notice denotes a hazard It calls attention to an operating procedure practice or the like that if not correctly performed or adhered to could result in damage to the product or loss of important data Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met A WARNING notice denotes a hazard It calls attention to an operating procedure practice or the like that if not correctly performed or adhered to could result in personal injury or death Do not proceed beyond a WARNING notice until the indicated conditions are fully understood and met TwisTorr 84 FS AG Rack ControllerUser Manual 87 901 037 01 A TwisTorr 84 FS AG Rack Controller TwisTorr 84 FS AG Rack Controller TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 3 297 TwisTorr 84 FS AG Rack Controller 4 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Contents Contents 1 Istruzioni per l uso 15 Informazioni Generali 16 Immagazzinamento 17 Preparazione per l installazione 18 Installazione 19 Uso20 Procedure diuso 23 Manutenzione 23 Smaltimento 24 Messaggi dierrore 25 2 Gebrauchsanleitung 27 Allgemeines 28 Lagerung 29 Vor der Installation 30 Installation 31 Gebrauch 32 Bedienung 35 Wartung 35
141. lle lk my sk n k ytt k pumppua mik li sis ntulon laippaa ei ole kytketty j rjestelm n tai mik li sit ei ole suljettu laippasulkijalla Sulkimen J1 liitin tulee j tt yhdyskaapelilla kytketyksi mik li ulkoisia kytkent j ei suoriteta Esityhji pumppu ja TwisTorr pumppu voidaan k ynnist samanaikaisesti 128 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Ohjekasikirja 10 Valvojan Saatimet Osoittimet ja Liittimet Seuraavassa on kuvattu valvojan etu ja takapaneelit Tarkempia lisatietoja saatte kappaleesta Technical Information Etupaneelin kuvaus 5 1 VACUUM TECHNOLOGIES a 5 hu 1 TwisTorr 84 FS AG O Kuva 2 Valvojien TwisTorr 84 AG etupanelit 1 Painonappi jonka avulla n ytt n saadaan kiertonumero kiertoaika ja pumpun toiminta 2 LOW SPEED moodin valintaan k ytett v painonappi Se aktivoituu vain silloin kun etupaneelin toiminta moodi on valittu Yhden kerran painettaessa pumppu kiert valmiustila nopeudella Painonappia uudelleen painettaessa LOW SPEED moodi disaktivoituu 3 Painonappi jonka avulla n ytt n saadaan pumpun s hk virran pumpun l mp tilan pumpun tehon ja kiertonopeuden parametrit T m on aina aktiivi riippumatta valitusta toimintamoodista Painamalla painonappeja 3 ja 1 v hint n kahden sekunnin ajan aktivoituu ohjel
142. ller with address 3 02 83 32 30 35 30 03 38 37 STX ADDR WINDOW RD ETX CRC Source Controller with address 3 in stop status Destination PC 02 83 3 13 13 3 13 13 13 13 13 03 3 3 2 10 15 10 0 10 O 10 0 8 7 ST ADD WINDOW DATA STATUS ET CRC X R X Command REAL SERIAL TYPE Source PC Destination Controller with address 8 in 485 mode 02 83 35 30 34 30 03 38 31 STX ADDR WINDOW RD ETX CRC Source Controller Destination PC 02 83 35 30 34 30 31 03 42 30 STX ADDR WINDOW RD DATA ETX CRC TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 241 297 17 Technical Information Window Meanings Tab 15 Accessories and Spare Parts N Read Data Description Admitted Values Write Type 000 R W L Start Stop in remote Front mode the Start 1 window is a read only Stop 0 001 R W L Low Speed Activation No 0 Yes 1 default 0 008 R W L Remote default or Serial configuration Remote 1 Serial 0 default 1 100 R W L Soft Start write only in Stop condition YES 1 NO 0 101 R W N R1 Set Point type 0 Frequency 1 Power 2 Time 3 Normal default 3 4 Pressure available only if the gauge is connected 102 R W R1 Set Point valve expressed in Hz Wors defa
143. ller te resetten en een tweede maal om de pomp weer op te starten 5 Alfanumeriek display met vloeibare kristallen LCD puntjespatroon 2 lijnen x 16 karakters TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 81 297 6 Bedrijfshandleiding 8 7 6 2 Achterpaneel van de controllers TwisTorr 84 AG 1 Connector voor ingang logische signalen de te koppelen connector wordt met de speciale sluitklem geleverd 2 Connector voor uitgang logische signalen en frequentiecontrole pomp plus programmeerbare analogische uitgang 3 Uitgangsconnector voeding 24 Vdc voor de koelventilator van de pomp vent valve en kaliber 4 Ingangsmodule voeding controller die de zekeringen het voedingscontact en het ENC filter bevat 5 Draaischakelaar om het adres van de Profibus in te stellen 6 Profibus optie 7 Seri le connector voor afstandsbesturing 8 Connector pomp 82 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Bedrijfshandleiding 6 Gebruiksprocedures Inschakelen van de controller Om de controller in te schakelen de voedingskabel in de netcontactdoos inbrengen Starten van de pomp Om de pomp te starten de interlock ingang inschakelen en op de START knop op het frontpaneel drukken Stoppen van de pomp Voor het stoppen van de pomp de STOP knop op het frontpaneel
144. lvos gases agresivos en ambientes explosivos o con alto riesgo de incendio Durante el funcionamiento es necesario que se respeten las condiciones ambientales siguientes temperatura de 5 C a 45 C humedad relativa 0 95 no condensadora Para otras conexiones y la instalaci n de los accesorios opcionales v ase la secci n Technical Information TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 55 297 4 Manual de istrucciones Uso En este apartado se citan los procedimientos operativos principales Para m s detalles y para procedimientos gue impliguen conexiones u opcionales especiales les remitimos al apartado Use del anexo Technical Informations Antes de usar el controler efectuar todas las conexiones el ctricas y neum ticas y consultar el manual de la bomba conectada ADVERTENCIA Para evitar lesiones a las personas y al aparato si la bomba est apoyada sobre una mesa cerciorarse que es estable No poner en marcha nunca la bomba si la brida de entrada no est conectada al sistema o no est cerrada con la brida de cierre El conector di cierre J1 ha de dejarse conectado con su conector puente si no se efect a ninguna conexi n exterior La bomba pre vacio y la bomba TwisTorr pueden encenderse simult neamente 56 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Manual de istrucciones 4 Mandos Indicadores y Conectores A c
145. ma jonka avulla on mahdollista ohjelmoida joitakin toimintaparametrej 4 START STOP RESET K YNNISTYKSEN PYS YTYKSEN UUDELLEN ASETUKSEN k skyjen painonappi Se aktivoituu vain silloin kun etupaneelin toiminta moodi on valittu Yhden kerran painettaessa k ynnistysvaihe aktioituu Uudelleen painettaessa pumppu pys htyy Mik li pumppu on toimintah iri n vuoksi pys htynyt automaattisesti painakaa painonappia yhden kerran jolloin valvoja saadaan asetettua uudelleen Toisen kerran painonappia painettaessa pumppu k ynnistyy 5 Kirjainnumerollinen digitaalin ytt pistematriisi 2 rivi x 16 merkki TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 129 297 10 Ohjek sikirja osado ol m Kuva 3 Valvojien TwisTorr 84 AG takapaneli 1 Logiikkasegnaalien tulokytkent pariliittimet toimitetaan niihin sopivilla vhdyskaapelisulkijalla 2 L htevien logiikkasignaalien ja pumpun taajuuden tarkkailun sek ohjelmoitavan analogisen ulostulon liitin 3 Virran ulostuloliitin 24 V tasavirta pumpun j hdytyssiivikolle vent valve ja kaliiperille 4 Valvojan tulovirran moduuli johon sis ltyv t sulakkeet virtapistoke ja suodatin ENC 5 Profibus osoitteen asettamiseen tarkoitettu kiertokytkin 6 Profibus valinnainen 7 Et ohjauksen sarjaliit nt 8 Pumpun liitin 130 297 T
146. masjon vises det til avsnittet Accessories and Spare Parts i vedlegget Technical Information Beskrivelse av frontpanelet 5 1 3 2 4 Figur 2 Frontpanelet p styreenheten TwisTorr 84 AG 1 Trykknapp for vise parametrene cycle number cycle time og pump life p displayet 2 Trykknapp for innstilling av LOW SPEED drift Trykknappen fungerer kun n r det er valgt styrem te fra frontpanelet Ved trykke p knappen n gang roterer pumpen i stand by hastighet Trykk p knappen igjen for g ut av LOW SPEED drift 3 Trykknapp for vise parametrene pump current pump temperature pump power og rotational speed p displayet Trykknappen fungerer alltid uavhengig av styrem ten N r trykknappene 3 og 1 trykkes ned samtidig i minst to sekunder startes et program som tillater programmering av visse driftsparametre 4 Trykknapp for overfaring av START STOP RESET Trykknappen fungerer kun nar det er valgt styrem te fra frontpanelet Trykk p knappen en gang for starte pumpen trykk p knappen igjen for stanse pumpen Har pumpen stanset automatisk i forbindelse med en feil trykk en gang p denne knappen for tilbakestille styreenheten en gang til for startet pumpen 5 LCD display med siffer og bokstaver punkt matrise 2 rader med 16 tegn TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A
147. n Programmable Analog Output Diagrams Output Voltage u Volt 10 freq max 0 Frequency Hz Figure 19 Diagram 1 Programmable analog output related to frequency freq max 1010Hz V Volt Output Voltage 10 0 150 Power W Figure 20 Diagram 2 Programmable analog output related to power V Volt 4 Output Voltage i EE 0 100 Pump Temp C Figure 21 Diagram 3 Programmable analog output related to pump 222 297 temperature TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Technical Information 17 Pump Connector A five meter long cable is available to connect the controller to the pump The following figure shows the controller output connector configuration where pins A F pump temperature sensor B C D 75 Vac 3 phase output to pump motor stator E lt EARTH PROTECTION PUMP FEMALE CONNECTOR 3 PHASE 7 PUMP TEMPERATURE SENSOR EARTH Figure 22 Controller to Pump Connector J5 Gauge Connector This connector is available to connect the Agilent active gauges The controller recognizes automatically the gauge connected by reading the signal identification in the connector Following a table with the gauge supported Gauge model Name showed in the display FRG 700 702 FRGa IMG 500 IMG PVG 500 502 PVGa FRG 720 730 FRGb IM 500 IM CDG 500 T1000
148. n est pas effectu e correctement risque de provoquer de graves l sions vadi Les messages d attention apparaissent avant certaines proc dures qui si elles ne sont pas observ es pourraient endommager s rieusement l appareillage Les notes contiennent des renseignements importants isol s du texte Emmagasinage Pendant le transport et l emmagasinage des contr leurs il faudra veiller respecter les conditions environnementales suivantes temp rature de 20 C 70 C humidit relative de 0 95 non condensante TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 41 297 3 Mode d emploi Preparation pour l installation 42 291 Le contr leur est fourni dans un emballage de protec tion sp cial si l on constate des marques de dommages pouvant s tre produits pendant le transport contacter aussit t le bureau de vente local Pendant l op ration d ouverture de l emballage veiller tout particuli rement ne pas laisser tomber le contr leur et ne lui faire subir aucun choc Ne pas jeter l emballage dans la nature Le mat riel est enti rement recyclable et il est conforme aux directives CEE 85 399 en mati re de protection de l environnement Figure 1 Emballage du Contr leur TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Installation 3 Installation Le contr leur doit tre aliment au moyen d un c ble d alimentation trois
149. n pump and controller then press the STOP RESET pushbutton twice to start the pump 290 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Technical Information 17 Orderable Parts Tab 22 Description Part number TwisTorr 84 FS AG Rack Controller with RS 232 485 X3508 64001 TwisTorr 84 FS AG Rack Controller with Profibus X3506 4002 option Turbo V 81 AG Nav Air cooling kit 0 5m 9699290 Turbo V 81 AG Nav Air cooling kit Extension cable 9699940 0m Vent Valve N O 0 5 mm orifice 0 5 m cable 9699844 Vent Valve extention cable 5 m 9699941 Mains cable NEMA plug 3 m 9699958 Mains cable european plug 3 m 9699957 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 291 297 Agilent Technologies Vacuum Products Division Dear Customer Thank you for purchasing an Agilent vacuum product At Agilent Vacuum Products Division we make every effort to ensure that you will be satisfied with the product and or service you have purchased As part of our Continuous Improvement effort we ask that you report to us any problem you may have had with the purchase or operation of our products On the back side you find a Corrective Action reguest form that you may fill out in the first part and return to us This form is intended to supplement normal lines of communications and to resolve problems that existing systems are not addressing in an adeguate or timely man
150. ndikatorer og Kontakter p Styreenheden 93 Beskrivelse af frontpanel 93 Instruktion 95 Start af styreenheden 95 Start af pumpen 95 Stop af pumpen 95 Vedligeholdelse 95 Bortskaffelse 96 Fejlmeddelelser 97 Overs ttelse af originalinstruktionerne RE Agilent Technologies 87 297 7 Istruktionsbog Generel Information 88 297 Dette materiel er beregnet til professionel anvendelse Brugeren bor l se denne brugsanvisning og anden yderligere information fra Agilent for udstyret anvendes Agilent tager ikke ansvar for skader helt eller delvis som folge af tilsides ttelse af disse instruktioner fejlagtig brug af personer uden tilstreekkelig kendskab ukorrekt anvendelse af udstyret eller h ndtering der strider imod geeldende lokale regler Styreenhederne i TwisTorr 84 Rack serien er mikroprocessorstyrede frekvens omformere der best r af komponenter med fast tilstand Styreenhed specifikationer Frontal fjern seriel styring a 24 Vdc styring af pumpens bl ser Vent valve styring a Aflesning af pumpens hastighed som f lge af tryk p stop aflesning af stophastighed a Aflesning af tryk Profibus brugerflade ekstra Automatisk indstilling af indgangsspendingen De f lgende afsnit indeholder al information der beh ves for at garantere operatgrens sikkerhed under anvendelsen Detaljeret information findes i bilaget Technical Information TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A
151. ne i odpowiada normom CEE 85 399 dotyczacym ochrony srodowiska Posta 1 Opakowanie kontrolerow 150 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Podrecznik Instrukcji 12 Instalacja ZAGROZENIE Kontroler jest zasilany przy uzyciu kabla skladajacego sie z trzech przewodow patrz tabela czesci na zamowienie i rodzaju wtyczki odpowiadajacej standartom miedzynarodowym gwarantujacego bezpieczne uzytkowanie Nalezy wylacznie uzywac tego rodzaju kabla zasilajacego i wlaczac wtyczke do gniazdka odpowiadajacego przepisom Unii Europejskiej tzn posiadajacego polaczenie z masa celem wykluczenia iskrzen We wnetrzu kontrolera powstaja wysokie napiecia ktore moga byc przyczyna powaznych obrazen lub wypadkow smiertelnych Przed przystapieniem do jakiejkolwiek operacji instalowania lub konserwacji nalezy odlaczyc go od zrodla zasilania Kontroler moze byc zainstalowany na stole lub wewnatrz odpowiedniego Rack W obydwu przypadkach nalezy pamietac aby wokol kontrolera zapewnic swobodny przeplyw powietrza dla prawidlowego chlodzenia Nie instalowac i lub uzytkowac kontrolerow w miejscach narazonych na dzialanie warunkow atmosferycznych jak deszcz mroz snieg pylow gazow agresywnych w srodowisku wybuchowym lub o duzym stopniu zagrozenia pozarowego Podczas pracy kontrolera nalezy zapewnic nastepujace warunki otoczenia temperatura od 5 C do 45 C a _wilgotnosc wzgledna 0 95 ni
152. ner Upon receipt of your Corrective Action Reguest we will determine the Root Cause of the problem and take the necessary actions to eliminate it You will be contacted by one of our employees who will review the problem with you and update you with the second part of the same form on our actions Your business is very important to us Please take the time and let us know how we can improve Sincerely Es gt Giampaolo LEVI Vice President and General Manager Agilent Vacuum Products Division Note Fax or mail the Customer Request for Action see backside page to Agilent Vacuum Products Division Torino Quality Assurance or to your nearest Agilent representative for onward transmission to the same address CUSTOMER REQUEST FOR CORRECTIVE PREVENTIVE IMPROVEMENT ACTION TO AGILENT VACUUM PRODUCTS DIVISION TORINO QUALITY ASSURANCE FAX N XXXX 011 9979350 ADDRESS AGILENT TECHNOLOGIES ITALIA S p A Vacuum Products Division Via F lli Varian 54 10040 Leini TO Italy E MAIL vpd qualityassurance_pdl ext agilent com NAME COMPANY FUNCTION ADDRESS TEL N FAX N E MAIL PROBLEM SUGGESTION REFERENCE INFORMATION model n serial n ordering information time to failure after installation etc DATE CORRECTIVE ACTION PLAN ACTUATION LOG N by AGILENT VPD XXX Code for dialing Italy from your country es 01139 from USA 00139 from Japan etc ig Agil
153. ng Delay Set the delay time between the stop command and vent opening Valid only in purge vent auto mode Parameter Buffer Offset 20 Bo 0 0 infinite the valve will never open 126 11 2 0 2sec bit 0 30000 Vent Valve Open Time Set how long the vent will remain open then both purge and vent will be closed Valid only in purge vent auto mode Parameter Buffer Offset 20 Bo 0 0 infinite the valve remain open till next start command 147 13 1 1 99 Setpoint 1 Hysteresis Set the Setpoint1 hysteresis around the nominal value 105 14 1 1 99 Setpoint 2 Hysteresis Set the Setpoint2 hysteresis around the nominal value 175 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 211 297 17 Technical Information 15 1 mBar Torr P 0 99 Setpoint 1 Pressure Value Mantissa 162 a Set the mantissa of the exponential value of the R1 setpoint format X XE XX when it is used for pressure monitoring Parameter Buffer Offset 21 Bo 2 4 The value set here is divided by 10 that means 11 1 1 16 1 10 10 Setpoint 1 Pressure Value Exponent 162 Set the exponent of the exponential value of the R1 setpoint format X XE XX when it is used for pressure monitoring Parameter Buffer Offset 21 Bo 2 4 17 1 mBar Torr P 0 99 Setpoint 2 Pressure Value Mantissa 176 a Set the mantissa of the exponential value of the R2 setpoint form
154. nge p START for at starte pumpen igen TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 97 297 7 98 297 Istruktionsbog MEDDELELSE BESKRIVELSE KONTROL TOO HIGH LOAD Under normal drift efter startfasen forbruger pumpen en st rre effekt end den programmerede vardi Kontroll r om pumpens rotor kan rotere frit Tryk to gange p START for at starte pumpen igen SHORT CIRCUIT Under normal drift efter startfasen er udgangseffekten kortsluttet Str mmen som optages af pumpen overskrider den programmerede v rdi Kontroll r forbindelserne mellem pumpe og styreenhed Tryk to gange p START for at starte pumpen igen SYSTEM OVERRIDE Pumpen er blevet standset af et n dstopsignal fra en fjernkontakt Frakobl styreenhedens stramkabel og kontroll r arsagen til nodstoppet Seet derefter stramkablet i Tryk to gange p START for at starte pumpen igen OVERVOLTAGE Der er opst et fejl i styreenhedens fodesp nding eller styreenheden har f et et falsk signal Tryk to gange p START knappen for at starte pumpen igen Hvis meddelelsen kommer igen tag kontakt med Agilent for nadvendig vedligeholdelse POWER FAIL Der er opst et fejl i sektionen for str mtilf rsel til pumpen styreenheden Tag kontakt med Agilent for Vedligeholdelse TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A TwisTorr 84 FS AG Rack Controlle
155. ning for den pdelagte styreenheten EVEN SSSR For noe arbeid utf res p styreenheten m den frakoples str mnettet Dersom en styreenhet skal kasseres m dette skje i henhold til nasjonale bestemmelser TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 119 297 9 Instruksjon Manual Eliminering Betydelsen av symbolet p logo WEEE p etikettene Symbolet nedenunder som finnes er anvendt i henhold til EC direktiv kalt WEEE Dette symbolet som bare gjelder for land i Det europeiske fellesselskap viser at produktet som det sitter p IKKE m behandles som vanlig hus industriavfall men m legges i kildesortering Derfor oppfordrer man den sluttelige brukeren av anordningen henvende seg til leverandgren av anordningen som kan v re et firma eller en forhandler som sgrger for oppsamling og eliminering etter ha kontrollert avtal 0g betingelser i kj pekontrakten 120 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Feilmeldinger Instruksjon Manual 9 N r det oppst r visse feil viser selvdiagnosekretsen i styreenheten den aktuelle feilmeldingen i displayet De aktuelle feilmeldingen fremg r av tabellen nedenfor Tab 1 MELDING BESKRIVELSE FORHOLDSREGEL CHECK CONNECTION TO PUMP Defekt kopling mellom pumpe og styreenhet Eller Pumpen har en temperatur under 0 C Kontroller at tilkoplingskabelen mellom pumpe og styreenhet er skikkelig monte
156. ntroller dobil nepristen znak Dvakrat pritisnite tipko START za ponoven zagon rpalke e se to obvestilo spet pojavi obrnite se Agilent za pravilno vzdr evanje POWER FAIL Kvar v oddelku napajanja rpalke controllera Obrnite se Agilent za pravilno vzdr evanje TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A TwisTorr 84 FS AG Rack Controller User Manual 16 Instructions for Use General Information 196 Storage 197 Preparation for Installation 198 Installation 199 Use 200 Controls Indicators and Connectors 201 Front Panel Description 201 Use Procedure 203 Controller Startup 203 Starting the Pump 203 Pump Shutdown 203 Maintenance 203 Disposal 204 Error Messages 205 Original Instructions s Agilent Technologies 195 297 16 Instructions for Use General Information 196 297 This eguipment is destined for use by professionals The user should read this instruction manual and any other additional information supplied by Agilent before operating the eguipment Agilent will not be held responsible for any events occurring due to non compliance even partial with these instructions improper use by untrained persons non authorised interference with the equipment or any action contrary to that provided for by specific national standards The TwisTorr 84 AG Rack controllers are micro processor controlled solid state frequency converter with self diagnostic and self protection
157. oi Utilisation Dans ce paragraphe on indique les principales proc dures op rationnelles Pour tous autres d tails et pour les proc dures concernant des connexions ou des l ments en option se reporter au paragraphe Use de appendice Technical Information Avant d utiliser le contr leur effectuer toutes les connexions lectrigues et pneumatiques et se r f rer la notice de la pompe connect e AVERTISSEMENT Pour viter tous dommages aux personnes et l appareil si la pompe est plac e sur un plateau d appui s assurer que ce dernier est stable Ne jamais faire fonctionner la pompe si la bride d entr e n est pas connect e au systeme ou n est pas ferm e aide de la bride de fermeture Laisser le connecteur de r enclenchement J1 connect sa barrette s il n est proc d aucune connexion ext rieure La pompe pr vide et la pompe TwisTorr peuvent tre mises en marche simultan ment 44 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Utilisation 3 Commandes Indicateurs et Connecteurs On pr sente ci dessous le tableau de commande du Contr leur ainsi que les tableaux d interconnexion Pour de plus amples d tails se reporter a la section Technical Information Description du Tableau avant Figure 2 Tableau avant du Contr leu
158. oller User Manual 87 901 037 01 A Technical Information 17 BYTES MEANING 13 Voltage 14 17 Frequency 18 19 Cycle 20 R1 Status 21 R2 Status 22 CRC The values for current and voltage are given as numbers scaled from 0 to 255 where 0 corresponds to 0 V and 255 to the full scale voltage 130 V or current 2 5 A When the Request is G the Answer will contain a string of 11 characters with the following parameters Tab 8 BYTES MEANING 1 2 Pump cycles number integer coded in 2 bytes 3 Speed threshold 4 7 Run up time in seconds long coded in 4 bytes 8 Deat time 0 NO 1 YES 9 Reserved 10 Soft Start mode 0 NO 1 YES 11 CRC When the configuration parameters have to be changed send a Reguest string with H characters of the following type H data CRC TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 233 297 17 Technical Information The following parameters can be changed Tab 9 BYTES MEANING 1 Speed threshold 2 5 Run up time in seconds long coded in 4 bytes 6 Deat time 0 NO 1 YES 7 Reserved 8 Soft Start mode 0 YES 1 NO 9 CRC When the Request is I Status readings the Answer will contain a string of 2 characters with the following parameters Tab 10 BYTES MEANING 1 MSB LSB XXX XXX N STARTING NORMAL OPERATION 5 HIGH LOAD FAILURE APPROA
159. onado o modo de comando do painel frontal Apertando o uma vez activa se a fase de arranque apertando o novamente p ra a bomba Se a bomba parou automaticamente por causa de uma avaria ocorre apertar este bot o uma primeira vez para executar o reset do controller e uma segunda vez para reiniciar a bomba 5 Display alfanum rico com cristais l quidos matriz de pontos 2 linhas x 16 caracteres TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 69 297 5 Manual de Istru es OE EE E Figura 3 Painel posterior dos Controllers TwisTorr 84 AG Conector de entrada dos sinais l gicos o conector de acoplamento fornecido com ponte espec fica de fecho 2 Conector sinais l gicos na sa da e monitoragem frequ ncia bomba mais sa da anal gica program vel 3 Conector de sa da alimentac o 24 Vdc para a ventoinha resfriamento bomba vent valve e calibragem 4 Modulo de entrada alimentac o controller que compreende os fus veis a tomada de alimentac o e o filtro ENC 5 Switch em rotac o para impostar o endereco do Profibus 6 Profibus opcional 7 Conector serial para controle de remoto 8 Conector bomba 70 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Manual de Istru es 5 Procedimentos de uso Acendimento do Controller Para ligar o controller
160. onfirm to place this declaration on the outside of the shipping box I declare that the above information is true and complete to the best of my knowledge and belief I understand and agree to the terms and conditions on page 2 of this document Name Authorized Signature Position Date NOTE If a product is received at Agilent which is contaminated with a toxic or hazardous material that was not disclosed the customer will be held responsible for all costs incurred to ensure the safe handling of the product and is liable for any harm or injury to Agilent employees as well as to any third party occurring as a result of exposure to toxic or hazardous materials present in the product Page 3 of 3 Agilent VPD Request for Return United States Agilent Technologies 121 Hartwell Avenue Lexington MA 02421 USA Tel 1 781 861 7200 Fax 1 781 860 5437 Toll Free 1 800 882 7426 vpl customerservice agilent com Benelux Agilent Technologies Netherlands B V Groenelaan 5 1186 AA Amstelveen The Netherlands Tel 31 20 547 2000 Fax 31 20 547 2093 Brazil Agilent Technologies Brasil Avenida Marcos Penteado de Ulhoa Rodrigues 939 6 andar Castelo Branco Office Park Torre Jacarand Tambor Barueri Sao Paulo CEP 06460 040 Toll free 0800 728 1405 China Agilent Technologies China Co Ltd No 3 Wang Jing Bei Lu Chao Yang District Beijing 100102 China Tel 86 0 10 64397888 Fax 86 0 10
161. ontinuaci n se ilustran el panel de mando del controler y los paneles de interconexi n Para m s detalles consultar la secci n Technical Information Descripci n del panel frontal 1 VACUUMTECHNOLOGIES 3 COUNTERS imi MEASURES increase next u r men 2 decrease previous 4 LOW SPEED START STOP 1 TwisTorr 84 FS AG O Figura 2 Panel frontal del Controller TwisTorr 84 AG 1 Pulsador para gue aparezcan en el display los par metros cycle number cycle time y pump life 2 Pulsador para la selecci n del modo LOW SPEED Est activado s lo cuando est seleccionado el modo de mando del panel frontal Apretando una vez la bomba gira a velocidad stand by Apret ndolo una vez m s se desactiva el modo LOW SPEED 3 Pulsador para gue aparezcan en el display los par metros pump current pump temperature pump power y rotational speed Est siempre activado independientemente del modo de funcionamiento elegido Apretando juntos los pulsadores 3 y 1 durante 2 segundos por lo menos se activa un programa con el cual se pueden programar algunos par metros operativos 4 Pulsador para enviar los mandos de START STOP RESET Est activo s lo cuando se selecciona el modo de mando del panel frontal Apret ndolo una vez se activa la fase de puesta en marcha apret ndolo otra vez se para la bomba Si la bomba se ha parado autom
162. orto contattare ufficio vendite locale Durante operazione di disimballaggio prestare particolare attenzione a non lasciar cadere il controller e a non sottoporlo ad urti Non disperdere imballo nel ambiente Il materiale completamente riciclabile e risponde alla direttiva CEE 85 399 per la tutela del ambiente Figura 1 Imballo dei controller 18 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Istruzioni per l uso 1 Installazione Il controller progettato solo per uso interno e deve essere alimentato mediante un cavo di alimentazione a tre fili vedere tabella delle parti ordinabili con una spina di tipo approvato a livello internazionale ai fini della sicurezza dell utente Utilizzare sempre questo cavo di alimentazione ed inserire la spina in una presa con un adeguato collegamento di terra onde evitare scariche elettriche e per rispettare le specifiche CE All interno del controller si sviluppano alte tensioni che possono recare gravi danni o la morte Prima di eseguire qualsiasi operazione di installazione o manutenzione del controller scollegarlo dalla presa di alimentazione Il controller pu essere installato su di un tavolo o all interno di un apposito rack In ogni caso occorre che l aria di raffreddamento possa circolare liberamente intorno all apparato Non installare n utilizzare il controller in ambienti esposti ad agenti atmosferici pioggia gelo neve polve
163. pa Per arrestare la pompa occorre premere il pulsante STOP del pannello frontale Manutenzione I controller della serie TwisTorr 84 Rack non richiedono alcuna manutenzione Qualsiasi intervento deve essere eseguito da personale autorizzato In caso di guasto possibile usufruire del servizio di riparazione Agilent o del Agilent advanced exchange service che permette di ottenere un controller rigenerato in sostituzione di quello guasto ANAT TA Prima di effettuare qualsiasi intervento sul controller scollegare il cavo di alimentazione Qualora un controller dovesse essere rottamato procedere alla sua eliminazione nel rispetto delle normative nazionali specifiche TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 23 297 1 Istruzioni per uso Smaltimento Significato del logo WEEE presente sulle etichette 11 simbolo qui sotto riportato applicato in ottemperanza alla direttiva CE denominata WEEE Questo simbolo valido solo per i paesi della Comunita Europea indica che il prodotto sul guale applicato NON deve essere smaltito insieme ai comuni rifiuti domestici o industriali ma deve essere avviato ad un sistema di raccolta differenziata Si invita pertanto utente finale a contattare il fornitore del dispositivo sia esso la casa madre o un rivenditore per avviare il processo di raccolta e smaltimento dopo opportuna verifica dei termini e condizioni contrattuali di vendita 24 297 TwisTor
164. peed of rotation of the pump when the low speed function is not active LOW SPEED Sets in Hz the speed of rotation of the pump when the low speed function is active SOFT START enables YES or disables NO the soft start function This parameter is visible only if the controller is configured in FRONT mode EXTERNAL FAN CNF Makes it possible to select driving mode of the external cooling fan Possible options ALWAYS ON the cooling fan is always ON OFF LIMPOWER 10 seconds after the pump has reached NORMAL status the fan is switched off and the driving power of the pump is reduced to 50 W SERIAL the cooling fan is controlled directly via the serial port VENT VALVE MODE makes it possible to select driving of the vent valve AUTO TIME the valve is controlled by the controller MANUAL the valve is controlled by the serial port AUTO PUMP SPEED the valve is controlled by the controller its king into account the pump s deceleration VENT VALVE DELAY Sets the delay expressed in seconds between stopping of the pump and opening of the vent valve VENT VALVE OPEN TIME sets the time expressed in seconds of opening of the vent valve Enter 0 if the valve is to be kept open indefinitely until the next start LOAD GAS TYPE selects the type of gas used in the process Therefore the controller limits the power supplied to the pump according to the setting of this parameter WATER COOLING indicates whet
165. pressure value measured XXXX shows the kind of gauge connected TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A The following messages may be displayed instead of the pressure GAUGE ERROR indicates that the GAUGE is not identified PRESSURE UNDER indicates that a pressure below the Technical Information 17 minimum threshold set has been measured PRESSURE OVER indicates that a pressure exceeding the maximum threshold set has been measured Pressing the COUNTERS key the following is obtained C Y IC IL JE X X X X T JI E XIX X X X OD TwisTorr 84 FS AG Figure 36 Where CYCLE XXXX Number of start stop cycles TIME XXXXXm Pressing again MAE XX X X XX Time of last cycle minutes h T Where PUMP LIFE XXXXXX pump TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A total operating time hours of the 257 297 17 Technical Information Programming Configuration Menu To access the configuration menu press the COUNTERS MEASURES buttons at the same time for at least 2 sec LOW SPEED TwisTorr 84 FS AG O O Figure 37 In programming mode the meaning of the 4 buttons changes as follows COUNTER
166. pust program s ktor m ke mo n zvoli niektor operat vne parameter 4 Tla idlo povelov TART STOP RESET Je akt vne iba vtedy ke povel vych dza z eln ho panelu Ke sa stla raz spust sa f za na tartovania stla iac ho znovu sa zastav erpadlo Ke sa erpadlo v pr pade poruchy zastav automaticky treba stla i tla idlo prv kr t pre resetovanie controller a druh kr t pre znovuna tarovanie erpadla 5 Alfanumerick displej na tekut kry t l bodov matica 2 l nie x 16 p smen TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 177 297 14 N vod na Obsluhu ED OE Postava 3 Zadn panel controller TwisTorr 84 AG Vstupn spojka logick ch sign lov spojovacia spojka je dogan s pr slu n m uzavieraj cim most kom Spojka v chodz ch logick ch sign lov a monitorovanie frekvencie erpadla a navy e programovate n analogick v stup V stup spojka nap jania 24 Vdc pre chladiacu lopatku erpadla vent valve a kaliber Vstupn modul nap jania controller u obsahuj ci poistky nap jaciu z suvku a filter ENC Rota n switch pre nastavenie adresy Profibusu Profibus na po iadavku S riov spojka pre dia kov kontrolu CO N B GI B w Spojka erpadla 178 297 TwisTo
167. r for igangs ttelse af afhentnings og bortskaffelsesprocessen efter ngje at have kontrolleret betingelserne i salgskontrakten TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Fejlmeddelelser Istruktionsbog 7 N r visse fejl opst r viser styreenheden ved selvdiagnose aktuelle fejl p displayet De mulige meddelelser listes i f lgende tabel Tab 1 MEDDELELSE BESKRIVELSE KONTROL CHECK CONNECTION TO PUMP Tilslutning mellem pumpe og styreenhed er defekt eller Temperaturen p pumpen ligger under 0 C Kontroll r at tilslutningskabel mellem pumpe og styreenhed er korrekt monteret samt at ingen afbrydninger forekommer Tryk to gange p START for at starte pumpen igen WAITING INTERLOCK Interlocksignalet findes p kontakt P1 p g a kortslutning mellem stift 3 og stift 8 i kontakten J1 eller p g a at det eksterne interlocksignal er bent Tilbagestil kortslutningen mellem stift 3 og stift 8 p kontakt P1 eller sluk for det eksterne interlocksignal PUMP OVERTEMP Temperaturen p det verste leje eller pumpen overskrider 60 C Vent p at temperaturen falder til under t rskelv rdi Tryk to gange p START for at starte pumpen igen CONTROLLER OVERTEMP Temperaturen p styreenhedens overskrider 70 C eller Temperaturen p styreenhedens koler overskrider 60 C Vent p at temperaturen falder til under t rskelv rdi Tryk to ga
168. r sente certains mes sages erreur indigu s dans le tableau ci dessous Tab 1 MESSAGE DESCRIPTION INTERVENTION CHECK Dysfonctionnement de la connexion S assurer que le c ble de CONNECTION entre la pompe et le contr leur connexion entre la pompe et TO PUMP Ou bien le contr leur et le contr leur La pompe a une temp rature est bien fix aux deux inf rieure a 0 C extr mit s et qu il n est pas coup Presser deux fois l interrupteur START pour r activer la pompe WAITING Le signal d interlock situ sur le R tablir le court circuit entre INTERLOCK connecteur P est actif cause de le pin 3 et le pin 8 du la coupure du court circuit entre le connecteur P1 ou fermer le pin 3 et le pin 8 du connecteur J1 signal d interlock ext rieur ou cause de l ouverture du signal d interlock ext rieur PUMP La temp rature du palier sup rieur Attendre que la temp rature OVERTEMP ou de la a d pass 60 C retourne au dessous du seuil Presser deux fois l interrupteur START pour remettre la pompe en marche CONTROLLER La temp rature du contr leur a Attendre que la temp rature OVERTEMP d pass 70 C retourne au dessous du Ou bien seuil Presser deux fois La temp rature du radiateur du l interrupteur START pour contr leur est sup rieure 60 C remettre la pompe en marche TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 49 297 3 Mode d emploi MESSAGE DESCRIPTION INTERVENTION
169. r 84 FS AG Rack Controller User Manual 87 901 037 01 A Messaggi di errore Istruzioni per l uso In alcuni casi di guasto la circuiteria di autodiagnosi del controller presenta alcuni messaggi di errore elencati nella tabella seguente Tab 1 MESSAGGIO DESCRIZIONE AZIONE CORRETTIVA 1 CHECK CONNECTION TO PUMP Malfunzionamento nel collegamento tra pompa e controller Oppure La pompa ha una temperatura inferiore a 0 C Verificare che il cavo di collegamento tra pompa e controller sia ben fissato da entrambe le estremit e non sia interrotto Premere due volte il pulsante START per riavviare la pompa WAITING INTERLOCK attivo il segnale di interlock presente sul connettore P1 a causa dell interruzione del corto circuito tra il pin 3 ed il pin 8 del connettore J1 o a causa dell apertura del segnale di interlock esterno Ripristinare il corto circuito tra il pin 3 ed il pin8 del connettore P o chiudere il segnale di interlock esterno PUMP OVERTEMP La temperatura del cuscinetto superiore o della pompa ha superato i 60 C Attendere che la temperatura ritorni al di sotto della soglia Premere due volte il pulsante START per riavviare la pompa CONTROLLER OVERTEMP La temperatura del ambiente del controller ha superato i 70 C Oppure La temperatura del radiatore del controller superiore a 60 C Attendere che la temperatura ritorni al di sotto della
170. r Manual 4 Manual de istrucciones Informaci n general 52 Almacenamiento 53 Preparaci n para la instalaci n 54 Instalaci n 55 Uso 56 Mandos Indicadores y Conectores 57 Descripci n del panel frontal 57 Procedimientos de uso 59 Encendido del controler59 Puesta en marcha de la Bomba 59 Parada de la Bomba 59 Mantenimiento 59 Eliminaci n 60 Mensajes de error 61 Traducci n de las instrucciones originales SHE Agilent Technologies 51 297 4 Manual de istrucciones Informaci n general 52 297 Este equipo se ha concebido para un uso profesional El usuario deber leer atentamente el presente manual de instrucciones y cualquier otra informaci n suplementaria facilitada por Agilent antes de utilizar el equipo Agilent se considera libre de cualquier responsabilidad debida al incumplimiento total o parcial de las instrucciones al uso poco apropiado por parte de personal sin formaci n a las operaciones no autorizadas o al uso que no cumpla con las normas nacionales espec ficas Los controlers de la serie TwisTorr 84 Rack son convertidores de frecuencia controlados por un microprocesador realizados con componentes en estado s lido y con capacidad de autodiagnosis y autoprotecci n Caracter sticas del controler a Operatividad frontal remoto serial a Pilotaje de 24 Vdc del ventilador de refrigeraci n bomba Pilotaje vent valve Lectura velocidad bomba despu s de activaci n mando de parada lectura veloc
171. r User Manual 8 Bruksanvisning Allman Information 100 F rvaring 101 Forberedelser f r installation 102 Installation 103 Anv ndning 104 Indikatorer och Kontakterp Styrenheten 105 Beskrivning av frontpanel 105 Instruktioner f r bruk 107 Start av styrenheten 107 Start av pumpen 107 Stopp av pumpen 107 Underh ll 107 Bortskaffning 108 Felmeddelanden 109 vers ttning av originalinstruktionerna RE Agilent Technologies 99 297 8 Bruksanvisning Allm n Information 100 297 Utrustningen r avsedd f r yrkesm ssig anv ndning Anv ndaren b r l sa denna bruksanvisning samt vrig dokumentation fran Agilent f re anv ndning av utrustningen Agilent tar inget ansvar f r skador som helt eller delvis orsakats av sidos ttande av instruktionerna ol mplig anv ndning av person utan tillr cklig kunskap obeh rigt bruk av utrustningen eller hantering som strider mot g llande lokala f reskrifter Styrenheterna i TwisTorr 84 Rack serien r mikroprocessor styrda frekvensomvandlare som best r av komponenter med fast tillst nd Styrenheterna r f rsedda med sj lvdiagnos och sj lvskyddsfunktion Styrenhetens egenskaper a Front fj rr seriell styrning 24 Vdc styrning av pumpens kylfl kt a Vent valve styrning a Avl sning av pumphastighet efter kommando f r stopp avl sning av stopphastighet a Avlasning av tryck a Profibus gr nssnitt option a Automatisk inst llning av insp nning De
172. r User Manual 87 901 037 01 A TwisTorr 84 FS AG Rack Controller User Manual Gebrauchsanleitung Allgemeines 28 Lagerung 29 Vor der Installation 30 Installation 31 Gebrauch 32 Steuerungen Anzeigen und Verbinder des Controllers 32 Fronttafel der Controller 33 Bedienung 35 Einschalten des Controllers 35 Pumpenstart 35 Pumpenstopp 35 Wartung 35 Entsorgung 36 Fehlermeldungen 37 bersetzung der Originalanleitungen RE Agilent Technologies 21 297 2 Gebrauchsanleitung Allgemeines 28 297 Dieser Apparat ist f r Fachbetriebe bestimmt Vor Gebrauch sollte der Benutzer dieses Handbuch sowie alle weiteren mitgelieferten Zusatzdokumentationen genau lesen Bei Nichtbeachtung auch teilweise der enthaltenen Hinweise unsachgem em Gebrauch durch ungeschultes Personal nicht autorisierten Eingriffen und Mif achtung der einheimischen hier zur Geltung kommenden Bestimmungen bernimmt die Firma Agilent keinerlei Haftung Die Controller der Serie TwisTorr 84 Rack sind mikroprozessorgesteuerte Frequenzwandler Sie sind mit Festk rperbauteilen gefertigt und verf gen ber ein Selbstdiagnose und ein Selbstschutzsystem Controllereigenschaften a Konsol Fern und serielle Operationen 24V K hlventilator Treiber Vent Valve Treiber Auslesen der Pumpgeschwindigkeit nach Stoppbefehl Lesen der Stoppgeschwindigkeit a Auslesen des Drucks a Profibus Schnittstelle Option a automatische Einstellung
173. r is responsible for the freight charges for the returning product Return shipments must comply with all applicable Shipping Regulations IATA DOT etc and carrier reguirements o Agilent Technologies is not responsible for returning customer provided packaging or containers o Customers receiving an Advance Exchange product agree to return the defective rebuildable part to Agilent Technologies within 15 business days Failure to do so or returning a non rebuildable part crashed will result in an invoice for the non returned non rebuildable part o Returns for credit toward the purchase of new or refurbished Products are subject to prior Agilent approval and may incur a restocking fee Please reference the original purchase order number o Units returned for evaluation will be evaluated and a guote for repair will be issued If you choose to have the unit repaired the cost of the evaluation will be deducted from the final repair pricing A Purchase Order for the final repair price should be issued within 3 weeks of guotation date Units without a Purchase Order for repair will be returned to the customer and the evaluation fee will be invoiced o Products returned that have not been drained from oil will be disposed o A Special Cleaning fee will apply to all exposed products o If reguesting a calibration service units must be functionally capable of being calibrated Page 20f3 Agilent VPD Reguest for Return Agilent Technologi
174. resahuje 60 C Po ka k m teplota neklesne pod hranicu Stla te dvakr t tla idlo START pre znovuna tartovanie erpadla TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 181 297 14 182 297 N vod na Obsluhu OZNAM POPIS Z SAH OPRAVY TOO HIGH LOAD Po as be n ho chodu po na tartovan erpadlom absorbovan pr d prevy uje ten naprogramovan Skontrolujte i m rotor erpadla mo nos to i sa vo ne Stla te dvakr t tla idlo START pre znovunastartovanie erpadla SHORT CIRCUIT Po as be n ho chodu po na tartovan v chodzie napojenie je v skrate Skontrolujte napojenia medzi erpadlom a controller Stla te dvakr t tla idlo START pre znovuna tartovanie erpadla SYSTEM OVERRIDE N dzov sign l vych dzaj ci z dia kov ho kontaktu zastavil erpadlo Vytiahnite n ru z elektrickej siete controller a ostr te d vod alarmu Zasu te nap jaciu Sn ru a stla te dvakr t tla idlo START pre znovuna tartovanie erpadla OVERVOLTAGE Objavila sa vada v sekcii nap jania controller alebo controller dostal falo n sign l Stla te dvakr t tla idlo START pre znovuna tartovanie erpadla Ke sa tento oznam objav znovu obr te sa na firmu Agilent pre dr bu POWER FAIL Vada v nap jacom syst me erpadla controllera Pre dr bu sa obr tte na Agilent
175. ri gas aggressivi in ambienti esplosivi o con elevato rischio di incendio Durante il funzionamento necessario che siano rispettate le seguenti condizioni ambientali temperatura da 5 C a 45 C a umidit relativa 0 95 non condensante Per gli altri collegamenti e l installazione degli accessori opzionali vedere la sezione Technical Information TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 19 297 1 Istruzioni per uso Uso In guesto paragrafo sono riportate le principali procedure operative Per ulteriori dettagli e per procedure che coinvolgono collegamenti o particolari opzionali fare riferimento al paragrafo Use del appendice Technical Information Prima di usare il controller effettuare tutti i collegamenti elettrici e pneumatici e fare riferimento al manuale della pompa collegata AVVERTENZA Per evitare danni alle persone ed al apparato nel caso in cui la pompa sia appoggiata su di un tavolo assicurarsi che sia stabile Non fare funzionare mai la pompa se la flangia di ingresso non collegata al sistema o non chiusa con la flangia di chiusura II connettore di richiusura J1 deve essere lasciato collegato con il suo ponticello se non viene effettuato alcun collegamento esterno La pompa di pre vuoto e la pompa TwisTorr possono essere accese contemporaneamente 20 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Istruzioni per l u
176. rr 84 FS AG Rack Controller User Manual 87 901 037 01 A N vod na Obsluhu 14 Postup pri pou it Zapnutie Controller Pre zapnutie controller sta zapoji k bel na elektrick sie a vyp na siete da do polohy 1 Na tartovanie erpadla Pre na tartovanie erpadla je potrebn spr stupni vstup linterlock a stla i tla idlo START na elnom paneli Zastavenie erpadla Pre zastavenie erpadla treba stla i tla idlo STOP na elnom paneli Udr ba Controllers s rie TwisTorr 84 Rack nevy aduj iadnu dr bu Ak ko vek z sah mus previes poveren person l V pr pade vady je mo n vyu i opravn slu bu Agilent alebo Agilent advanced exchange service ktor vymen vadn controller MINE Pred ak mko vek z sahom na controller vytiahnite n ru z elektrickej siete V pr pade e controller mus s do zberu ria te sa platn mi pr slu n mi n rodn mi normami TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 179 297 14 N vod na Obsluhu Likvid cia V znam loga WEEE nach dzaj ceho sa na t tkoch Aplikovanie doluozzna en ho symbolu dodr uje smernicu E s n zvom WEEE Tento symbol platn iba pre t ty Eur pskej nie znamen e v robok s t mto t tkom NESMIE by odstr nen spolu s be n m dom cim alebo priemyseln m odpadom ale sa mus odstr ni ako delen odpad Vyz vame pre
177. rs TwisTorr 84 AG 1 Interrupteur rappelant sur l afficheur les param tres de cycle number cycle time et pump life 2 Interrupteur de s lection du mode LOW SPEED II n est actif que lorsque le mode de commande est s lectionn depuis le tableau frontal En le pressant une fois la pompe tourne vitesse stand by En le pressant une deuxi me fois on d sactive le mode LOW SPEED 3 Interrupteur rappelant sur l afficheur les param tres de pump current pump temperature pump power et rotational speed II est toujours actif ind pendamment du mode de fonctionnement choisi En pressant simultan ment les interrupteurs 3 et 1 pendant 2 secondes au moins on active un programme avec leguel il est possible de programmer certains param tres op rationnels 4 Interrupteur envoyant les commandes de START STOP RESET II n est actif que lorsque le mode de commande est s lectionn depuis le tableau frontal Une premi re pression de l interrupteur active la phase de mise en marche une deuxi me pression provoque l arr t de la pompe Si la pompe s est arr t e automatiquement cause d une panne il faut presser cet interrupteur une premi re fois pour effectuer la mise z ro du contr leur et une deuxi me fois pour remettre la pompe en marche 5 Ecran alphanum rique cristaux liquides matrice de points 2 lignes x 16 caract res TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 45 297 3 Mod
178. rt samt at kabelen ikke er skadet Trykk to ganger p knappen START for starte pumpen WAITING INTERLOCK L sesignalet for kontakt P1 skyldes en kortslutning mellom stift 3 og stift 8 i kontakten J1 eller fordi det eksterne l sesignalet er pent Tilbakestill kortslutningen mellom stift 3 og stift 8 p kontakt P1 eller steng det eksterne l sesignalet PUMP OVERTEMP Temperaturen p det vre lageret eller pumpen er over 60 C Vent til temperaturen synker under terskelverdien Trykk to ganger p knappen START for starte pumpen CONTROLLER OVERTEMP Temperaturen p styreenhetens er over 70 C Eller Temperaturen p radiatoren p styreenheten er over 60 C Vent til temperaturen synker under terskelverdien Trykk to ganger p knappen START for starte pumpen TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 121 297 9 122 297 Instruksjon Manual MELDING BESKRIVELSE FORHOLDSREGEL TOO HIGH Den absorberte strammen av Kontroller om pumpens rotor LOAD pumpen er starre enn den som er kan rotere fritt programmert Trykk to ganger pa knappen START for a starte pumpen SHORT Ved normal drift etter startmo Kontroller tilkoplingene CIRCUIT mentet er utgangen kortsluttet mellom pumpe og styreenhet Trykk to ganger pa knappen START for a starte pumpen SYSTEM Pumpen har stanset av et Kople fra styreenhetens OVERRIDE nadstoppsignal en fra fjern
179. rtaa jolloin pumppu k ynnistyy CONTROLLER OVERTEMP Valvojan muuntajan l mp tila on 70 C Tai Valvojan l mmittimen l mp tila on korkeampi kuin 60 C Odottakaa ett l mp tila putoaa kynnysarvon alapuolelle Painakaa painonappia START kaksi kertaa jolloin pumppu kaynnistyy TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 133 297 10 Ohjek sikirja VIESTI VIKA KORJAUSTOIMENPITEET TOO HIGH Pumpun absorptiovirta ylitt Tarkistakaa ett pumpun LOAD ohjelmoidun arvon roottori py rii vapaasti Painakaa painonappia START kaksi kertaa jolloin pumppu kaynnistyy SHORT Normaality skentelyn aikana Tarkistakaa pumpun ja valvojan CIRCUIT k ynni styksen j lkeen v linen liitos Painakaa poistoliitin on oikosulussa painonappia START kaksi kertaa jolloin pumppu k ynnistyy SYSTEM Kaukokytkimest tuleva Irroittakaa valvojan OVERRIDE h lytyssignaali on pys ytt nyt s hk kaapeli verkkovirrasta ja pumpun korjatkaa h lytyksen aiheuttaja Kytkek s hk kaapeli uudelleen ja painakaa painonappia START kaksi kertaa jolloin pumppu k ynnistyy OVERVOLTAGE Valvojan s hk virran sy t ss on Painakaa painonappia START ilmennyt ongelma tai valvojan kaksi kertaa jolloin pumppu saama signaali on v r k ynnistyy Mik li viesti n kyy uudelleen k ntyk Agilent huoltopalvelun puoleen POWER FAIL Vika pumpun valvojan K ntyk Agilent yhti n
180. rwencja moze byc dokonywana wylacznie przez osoby autoryzowane W przypadku uszkodzenia mozliwe jest korzystanie z serwisow naprawczych Agilent lub Agilent advance exchange service w ktorym mozna otrzymac kontroler zregenerowany zastepujac go tym uszkodzonym Przed wykonaniem jakiejkolwiek interwencji na kontrolerze nalezy odlaczyc kabel zasilajacy W przypadku decyzji zlomowania nalezy przeprowadzic operacje respektujac krajowe specyficzne normy TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 155 297 12 Podrecznik Instrukcji Przetworstwo odpadow Objasnienie znajdujacego sie na etykiecie znaczenia logo WEEE Uzyty ponizej symbol jest zgodny z wymogiem zarzadzenia WEEE Unii Europejskiej Symbol ten prawomocny tylko w krajach Unii Europejskiej oznacza ze wyrob ktory nim zostal oznaczony NIE moze byc przetworzony jako odpad razem z innymi domowymi lub przemyslowymi natomiast musi byc skladowany w miejscu przeznaczonym dla odpadow do przerobki zroznicowanej Dlatego tez poleca sie uzytkownikowi po uprzedniej weryfikacji terminu i warunkow zawartych w kontrakcie sprzedazy nawiazac kontakt z dostawca lub sprzedawca urzadzenia w celu uruchomienia procesu zbiorki i przerobu 156 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Bledne informacje Podrecznik Instrukcji 12 W niektorych przypadkach uszodzen obwod do autodiagnozy kontrolera pokazuje blendne informa
181. sa ou no interior de um rack espec fico Em todo caso necess rio que o ar de refrigera o possa circular livremente ao redor da aparelhagem N o instalar e ou utilizar o controller em ambientes expostos a agentes atmosf ricos chuva gelo neve poeiras gases agressivos ou em ambientes com perigo de explos o ou com elevado risco de inc ndio Durante o funcionamento necess rio que sejam respeitadas as seguintes condi es ambientais temperatura de 5 C a 45 C humidade relativa 0 95 n o condensante Para as outras liga es e a instalac o dos acess rios opcionais ver a sec o Technical Information TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 67 297 5 Manual de Istru es Utilizac o Neste par grafo s o descritos os principais procedimentos operativos Para maiores detalhes e para procedimentos que envolvem liga es ou pecas opcionais consultar o par grafo Use do ap ndice Technical Information Antes de usar o controller efectuar todas as liga es el ctricas e pneum ticas e consultar o manual da bomba ligada ATENCAO Para evitar danos s pessoas e aparelhagem caso a bomba esteja apoiada numa mesa certificar se que esteja est vel Nunca activar a bomba se o flange de entrada n o estiver ligado ao sistema ou n o estiver fechado com o flange de fecho 0 conector de fecho J1 deve permanecer ligado sua ponte se n o efectuad
182. sador START para volver a poner en marcha la bomba CONTROLLER OVERTEMP La temperatura del controler ha superado los 70 C 0 bien La temperatura del radiador del controler es superior a 60 C Esperar a que la temperatura vuelva por debajo del umbral Apretar dos veces el pulsador START para volver a poner en marcha la bomba TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 61 297 4 Manual de istrucciones MENSAJE DESCRIPCI N ACCI N CORRECTIVA TOO HIGH LOAD La corriente absorbida por la bomba es superior a la programada Comprobar gue el rotor de la bomba tiene la posibilidad de girar libremente Apretar dos veces el pulsador START para volver a poner en marcha la bomba SHORT CIRCUIT Durante el funcionamiento normal tras la fase de puesta en marcha la conexi n de salida est en cortocircuito Comprobar las conexiones entre la bomba y el controler Apretar dos veces el pulsador START para volver a poner en marcha la bomba SYSTEM OVERRIDE La bomba ha sido parada por una se al de emergencia procedente de un contacto remoto Desenchufar el cable de alimentaci n del controler y corregir la causa de la emergencia Volver a conectar el cable de alimentaci n y apretar dos veces el pulsador START para volver a poner en marcha la bomba OVERVOLTAGE Se ha producido una aver a en la secci n de alimentaci n del controler o el controler
183. so 1 Comandi Indicatori e Connettori Di seguito sono illustrati il pannello di comando del Controller ed i pannelli di interconnessione Per maggiori dettagli fare riferimento alla sezione Technical Information Descrizione pannello frontale 1 3 5 ru 1 TwisTorr 84 FS AG O Figura 2 Pannello frontale del Controller TwisTorr 84 AG 1 Pulsante per richiamare sul display i parametri cycle number cycle time e pump life 2 Pulsante per la selezione del modo LOW SPEED attivo solo quando selezionato il modo di comando dal pannello frontale Premendolo una volta la pompa ruota a velocit stand by Premendolo ancora si disattiva il modo LOW SPEED 3 Pulsante per richiamare sul display i parametri pump current pump temperature pump power e rotational speed sempre attivo indipendentemente dal modo di funzionamento scelto Premendo assieme i pulsanti 3 e 1 per almeno 2 secondi viene attivato un programma con il quale possibile programmare alcuni parametri operativi 4 Pulsante per inviare i comandi di START STOP RESET attivo solo quando selezionato il modo di comando dal pannello frontale Premendolo una volta si attiva la fase di avvio premendolo nuovamente si arresta la pompa Se la pompa si fermata automaticamente a causa di un guasto occorre premere questo pulsante una prima volta per eseguire
184. sser eksplosjonsfarlige milj er eller i milj er med stor brannfare Under bruk m folgende forhold respekteres temperatur fra 5 C til 45 C a relativ fuktighet 0 95 uten kondens N r det gjelder andre tilkoplinger og installasjon av ekstrautstyr vises det til avsnittet Technical Information TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 115 297 9 Instruksjon Manual Bruk Dette avsnittet beskriver de viktigste driftsmomentene For en detaljert beskrivelse samt moment som omfatter tilkoplinger eller ekstrautstyr vises det til avsnittet Use i vedlegget Technical Information F r styreenheten tas i bruk bor samtlige elektriske og pneumatiske tilkoplinger gjgres Les brukerveiledningen for pumpen som er tilkoplet Dersom pumpen er installert p et bord m du kontrollere at pumpen st r stott Dette er viktig for forhindre skader p apparatet og p personer Dersom inngangsflensen hverken er tilkoplet systemet eller dersom den er blokkert av l seflensen m pumpen aldri startes opp Lukkekontakten J1 m v re tilkoplet aktuell brygge dersom det ikke skjer en annen ekstern tilkopling Forvakuumpumpen og TwisTorr pumpen m fungere sammen 116 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Instruksjon Manual 9 Indikatorer og Kontakter p Styreenheten Nedenunder er frontpanelet og bakpanelet p styreenheten illustrert For ytterligere infor
185. st ammattitaidottomien henkil iden suorittamasta laitteen virheellisest k yt st valtuuttamattomista toimenpiteist tai maakohtaisten s d sten ja normien vastaisesta k yt st Sarjan TwisTorr 84 Rack valvojat ovat mikroprosessoreiden valvomia kiinteist materiaaleista tehtyj taajuudenmuuntimia jotka kykenev t itsem rittelyyn ja itsesuojaukseen Valvojan ominaisuudet K ytett vyys etupaneelista et k ytt sarjak ytt Pumpun j hdytyssiivikon 24V tasavirtaohjaus Vent valve ohjaus Pumpun nopeuden luku pys ytysk skyn j lkeen pys ytysnopeuden luku Paineen luku Profibus liit nt valinnainen Automaattinen sis ntulon j nnitteen asetus Seuraavilla sivuilla on luettavissa tarpeelliset tiedot laitteen k ytt j n turvallisuuden takaamiseksi laitteen k yt n aikana Yksityiskohtaiset tiedot l ytyv t liitteest Technical Information 124 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Ohjekasikirja 10 T m ohjekirja k ytt seuraavia merkint j VACIO Vaara merkinn t saavat k ytt j n huomion kiinnittym n erityisiin toimintotapoihin joiden seuraamatta j tt minen voi aiheuttaa vakavia henkil vaurioita Huomio merkinn t varoittavat toiminnoista joiden laiminly nti voi johtaa laitteen vaurioitumiseen Huomiot sis lt v t t rke tekstist otettua tietoa Varastointi Valvojan kuljetuksen ja varastoinnin a
186. st n r styrs tt fr n frontpanelen har valts Genom att trycka p knappen en g ng kommer pumpen att rotera vid standby hastighet Tryck p knappen igen f r att ga ur LOW SPEED drifts ttet 3 Tryckknapp f r att h mta parametrarna pump current pump temperature pump power och rotational speed p displayen Tryckknappen fungerar alltid oavsett det valda styrs ttet N r tryckknapparna 3 och 1 h lls samtidigt intryckta i minst 2 sekunder startas ett program som till ter att programmera vissa driftparametrar 4 Tryckknapp f r verf ring av START STOP RESET Tryckknappen fungerar endast n r styrs tt fr n frontpanelen har valts Tryck p knappen en g ng f r att starta pumpen tryck p knappen igen f r att stanna pumpen Om pumpen stannat automatiskt i samband med ett fel tryck p denna knapp en g ng f r att terst lla styrenheten och ytterligare en g ng f r att starta om pumpen 5 LCD display med siffror och bokst ver punktmatris 2 rader med 16 tecken TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 105 297 8 Bruksanvisning ED OE Figur 3 Bakre panel p Styrenheten TwisTorr 84 AG 1 Ing ngskontakt f r logiska signaler anslutnings kontakten levereras med speciell st ngningsbrygga 2 Kontakt f r utg ende logiksignaler och kontroll av pumpfrekvens pl
187. t ng den externa eller p grund av att den externa interlock signalen interlock signalen r ppen PUMP Temperaturen p det vre lagret V nta tills temperaturen OVERTEMP eller pumpen verskrider 60 C sjunker under tr skelv rdet Tryck tv g nger p knappen START f r att starta om pumpen CONTROLLER Temperaturen p styrenhetens V nta tills temperaturen OVERTEMP verskrider 70 C sjunker under tr skelv rdet eller ocks Temperaturen p styrenhetens kylare verskrider 60 C Tryck tv g nger p knappen START f r att starta om pumpen TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 109 297 8 110 297 Bruksanvisning MEDDELANDE BESKRIVNING ATGARD TOO HIGH LOAD Str mmen som absorberas av pumpen verstiger det varde som programmerats Kontrollera att pumpens rotor kan rotera fritt Tryck tva ganger pa knappen START f r att starta om pumpen SHORT CIRCUIT Under normal drift efter startmomentet har utgangen kortslutits Kontrollera anslutningarna mellan pump och styrenhet Tryck tva ganger pa knappen START f r att starta om pumpen SYSTEM OVERRIDE Pumpen har stannats av en n dstoppssignal fran en fjarrkontakt Frankoppla styrenhetens str mkabel och kontrollera n dstoppets orsak S tt d refter i str mkabeln Tryck tv g nger p knappen START f r att starta om pumpen OVERVOLTAGE Ett fel i styrenhetens matn
188. t shall not be liable for errors or for incidental or conseguential damages in connection with the furnishing use or performance of this document or of any information contained herein Should Agilent and the user have a separate written agreement with warranty terms covering the material in this document that conflict with these terms the warranty terms in the separate agreement shall control Technology Licenses The hardware and or software described in this document are furnished under a license and may be used or copied only in accordance with the terms of such license Restricted Rights Legend If software is for use in the performance of a U S Government prime contract or subcontract Software is delivered and licensed as Commercial computer software as defined in DFAR 252 227 7014 June 1995 or as a commercial item as defined in FAR 2 101 a or as Restricted computer software as defined in FAR 52 227 19 June 1987 or any equivalent agency regulation or contract clause Use duplication or disclosure of Software is subject to Agilent Technologies standard commercial license terms and non DOD Departments and Agencies of the U S Government will receive no greater than Restricted Rights as defined in FAR 52 227 19 c 1 2 June 1987 U S Government users will receive no greater than Limited Rights as defined in FAR 52 227 14 June 1987 or DFAR 252 227 7015 b 2 November 1995 as applicab
189. tatus of the last attempt to write a parameter with following coding diag status byte 0 1 2 3 4 5 6 F Write success Controller response was NACK Controller response was Unknown window Controller response was Bad Data Type Controller response was Over range Controller response was Bad operation Controller response was an unknown response Parameter not supported by the controller The ProfiBus external diagnosis services are used to report following unexpected situations Controller fail if the controller goes in fail mode an external diagnostic service is required and one byte in the diagnostic buffer signals the type of failure User parameter mismatch if the user sets one or more parameters out of their allowed range a ProfiBus external diagnostic service is required and some bits in the diagnosis frame signals which parameter is wrong i e over range or under range TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 285 297 17 Technical Information 286 297 Diagnostic Buffer Tab 21 Diagnostic buffer OFF SET MEANING 0 Bo station non exist set by master Bi station not ready slave not ready for data exchange B2 cfg fault configuration data doesn t match B3 ext diag slave has external diagnostic data Ba not supported slave doesn t support requested function Bs invalid slave response slave sets permanent 0 Be prm fault
190. te styretype N r trykknapperne 3 og 1 holdes trykket ind samtidigt i mindst 2 sekunder starter et program der tillader at programmere visse driftparametre 4 Trykknap til overfaring af START STOP RESET Trykknappen fungerer kun n r der v lges fra frontpanelet Tryk p knappen en gang for at starte pumpen tryk p knappen igen for at standse pumpen Hvis pumpen standser automatisk ved en fejl tryk p denne knap en gang for at tilbagestille styreenheden og yderligere en gang for at starte pumpen igen 5 LCD display med tal og bogstaver punktmatrice 2 rader med 16 tegn TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 93 297 7 Istruktionsbog ED OE Figur 3 Bagpanelet p Styreenheden TwisTorr 84 AG 1 Indgangskontakt til logiske signaler tilslutningskontakten leveres med speciel forbindelsesbro 2 Udgangskontakt til logiske signaler og kontrol af pumpens frekvens samt programmerbar analog udgang Udtag 24 Vdc til pumpens bl ser vent valve og manometer Indgangsmodul til styreenhed omfattende sikringer str mudtag og ENC filter Drejekontakt til indstilling af Profibus adressen Profibus ekstra Seriel kontakt til fjernkontrol CO N B GI B w Pumpekontakt 94 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Istr
191. ten o TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A TwisTorr 84 FS AG Rack Controller User Manual 6 Bedrijfshandleiding Algemene informatie 76 Opslag 77 Voorbereiding voor installatie 78 Installatie 79 Gebruik 80 Bedieningsorganen Controlelampjes en Connectoren van 81 Beschrijving frontpaneel 81 Gebruiksprocedures 81 Inschakelen van de controller 83 Starten van de pomp 83 Stoppen van de pomp 83 Onderhoud 83 Afvalverwerking 84 Foutmeldingen 85 Vertaling van de originele instructies RE Agilent Technologies 75 297 6 Bedrijfshandleiding Algemene informatie 76 297 Deze apparatuur is bestemd voor beroepsmatig gebruik De gebruiker wordt verzocht aandachtig deze handleiding en alle overige door Agilent verstrekte informatie door te lezen alvorens het apparaat in gebruik te nemen Agilent acht zich niet aansprakelijk voor de gevolgen van het niet of gedeeltelijk in acht nemen van de aanwijzingen onoordeelkundig gebruik door niet hiervoor opgeleid personeel reparaties waarvoor geen toestemming is verkregen of gebruik in strijd met de specifieke nationale wetgeving De controllers van de TwisTorr 84 Rack serie zijn freguentieomzetters die gestuurd worden door een microprocessor zijn gemaakt van halfgeleiderele menten en zijn in staat om zelfdiagnose en zelfbescherming uit te voeren Kenmerken van de controller Bediening frontaal op afstand serieel a Sturing met 24 Vdc van de
192. ticamente a causa de una aver a hay que apretar este pulsador primero una vez para efectuar el reset del controler y la segunda vez para volver a poner en marcha la bomba 5 Display alfanum rico de cristales l quidos matriz de puntos 2 l neas x 16 caracteres TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 57 297 4 Manual de istrucciones Figura 3 Panel trasero del controler TwisTorr 84 AG Conector de entrada de las se ales l gicas el conector de acoplamiento se suministra con el conector puente espec fico de cierre 2 Conector se ales l gicas en salida y monitoreo frecuencia bomba y salida anal gica programable 3 Conector de salida alimentaci n 24 Vdc para el ventilador de refrigeraci n bomba vent valve y calibre 4 M dulo de entrada alimentaci n controler con fusibles toma de alimentaci n y filtro ENC 5 Conmutador de rotaci n para configurar la direcci n del Profibus 6 Profibus opcional 7 Conector serial para control remoto 8 Conector bomba 58 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Manual de istrucciones 4 Procedimientos de uso Encendido del controler Para encender el controler es suficiente introducir el cable de alimentaci n en la toma de red Puesta en marcha de la Bomba Para activar la bomba es nec
193. to Use by Remote 1 0 271 How to Use in Serial Mode 271 Profibus Option 273 General 273 Installation273 Configuration 274 Software Operation and State Machine 274 Message Mapping 276 Parameter Buffer 277 Output Buffer 280 Input Buffer 281 Diagnostic Management 284 Diagnostic Buffer 286 Error Messages 288 Orderable Parts 291 208 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Technical Information 17 TwisTorr 84 Rack Controller Description The controller is available in three models see orderable parts table a base version with RS 232 485 option with Profibus option The controller is a solid state freguency converter with the following features a Drives the pumps of the 84 NAV family Powers the pump cooling fan Drives the vent valve Provides and acquires the pressure of the wide range gauge Remote I Os compatible with the previous version Navigator default serial compatible with the previous RS 232 and 485 version Speed reading after stop command See the following diagram for the connections and orderable parts TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 209 297 17 Technical Information AIR COOLING KIT VENT VALVE AIR COOLING KIT EXTENTION CABLE kes CONTROLLER TO POWER SUPPLY
194. to kone n ho u vate a aby sa skontaktoval s dod vate om pr stroja i u je to v robca alebo predajca za elom jeho likvid cie pod a zmluvn ch podmienok predaja 180 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Oznamy v d N vod na Obsluhu 14 V niektor ch pr padoch t kaj cich sa v d obvod samodiagnostiky controller signalizuje nieko ko oznamov v d uveden ch na al ej strane Tab 1 OZNAM POPIS Z SAH OPRAVY CHECK CONNECTION TO PUMP Nefunguje napojenie medzi erpadlom a controller Alebo erpadlo m ni iu teplotu ako 0 C Skontrolujte i je spojovac k bel medzi erpadlom a controller spr vne zasunut na obidvoch koncoch a i nie je preru en Stla te dvakr t tla idlo START pre znovuna tartovanie erpadla WAITING INTERLOCK je akt vny sign l interlock na spojke P1 z d vodu preru enia skratu medzi pin 3 a pin 8 spojky J1 alebo z d vodu otvorenia sign lu vonkaj ieho interlock Obnovi skrat medzi pin 3 a pin 8 spojky P alebo zavrie sign l vonkaj ieho interlock PUMP OVERTEMP Teplota horn ho lo iska alebo erpadla prekro ila 60 C Vy ka a sa teplota op vr ti pod hranicu Stla te dvakr t tla idlo START pre znovuna tartovanie erpadla CONTROLLER OVERTEMP Teplota controller prekro ila 70 C Alebo Teplota radi tora controllera p
195. u a po kodeniu pr stroja skontrolujte aby erpadlo umiestnen na pracovnom stole bolo stabiln erpadlo nikdy nena tartujte vtedy ke vstupn pr ruba nie je napojen na syst m alebo nie je zavret s uz verovou pr rubou Uzavieraj ca pr pojka J1 sa mus necha napojen na jej most k vtedy ke nie je preveden iadne vonkaj ie napojenie Pred pr zdnov erpadlo a erpadlo TwisTorr m u by zapnut s asne 176 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A N vod na Obsluhu 14 Povely Ukazovatele a Pr pojky Controller alej je zobrazen eln a zadn panel controller a Pre al ie detaily konzultuje as Technical Information Popis eln ho panelu D LOW SPEED TwisTorr 84 FS AG O O Postava 2 eln panel Controller TwisTorr 84 AG 1 Tla idlo pre vyvolanie parametrov cycle number cycle time a pump life na displej 2 Tla idlo pre vo bu LOW SPEED Je akt vne iba vtedy ke povel vych dza z eln ho panelu Ke sa stla raz cerpadlo sa to r chlos ou stand by Stla iac ho druh raz sa vypne LOW SPEED 3 Tla idlo pre vyvolanie parametrov pump current pump temperature pump power rotational speed Je stale akt vne nez visle od vo by funkcie Stla iac spolu tla idl 3 a 1 na aspo 2 sekundy sa s
196. uktionsbog 7 Instruktion Start af styreenheden Styreenheden startes ved at s tte str mkablet i v gudtaget Start af pumpen Pumpen startes ved at aktivere interlock indgangen og trykke p START knappen p frontpanelet Stop af pumpen Pumpen stopper ved at trykke p STOP trykknappen p frontpanelet Vedligeholdelse Styreenhederne i TwisTorr 84 Rack serien behgver ikke nogen vedligeholdelse Ethvert indgreb p pumpen skal foretages af autoriseret personale Hvis pumpen g r i stykker kan man benytte sig af Agilents reparations service eller Agilent udvekslingsservice hvor man kan f en repareret pumpe i bytte for den der er g et i stykker IAEA Inden der foretages noget som helst indgreb p styreenheden skal str mmen f rst afbrydes Skrotning af pumpen skal foreg i overensstemmelse med det p g ldende lands s rlige love TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 95 297 7 Istruktionsbog Bortskaffelse 96 297 Betydningen af WEEE logoet p m rkaterne Nedenst ende symbol anvendes i overensstemmelse med det s kaldte EU direktiv WEEE Symbolet kun g ldende for EU landene viser at produktet som det sidder p IKKE m bortskaffes sammen med affald fra private husholdninger eller industriel affald men skal indleveres p en godkendt affaldsstation Vi opfordrer derfor slutbrugeren til at kontakte leverand ren af anordningen enten fabrikken eller en forhandle
197. ult 900 103 R W Set Point delay time between the pump 0 to 99999 default 0 start and the set point check seconds 104 R W L Set Point signal activation type the signal 0 high level active can be high level active or low level 1 low level active active default 0 105 R W N Set point hysteresis in of value 0 to 100 default 2 106 R W Water cooling 0 NO 1 YES 107 R W L Active Stop write only in stop 0 NO 1 lt YES 108 R W N Baud rate 600 0 1200 1 2400 2 4800 3 9600 4 default 4 242 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Technical Information 17 109 W L Pump life cycle time cycle number To reset write 1 reset 110 R W L Interlock type default 0 Impulse 0 Continuous 1 111 R W L Analog output type output voltage signal 0 frequency proportional to frequency power 1 power temperature or pressure default 2 Pump temperature 3 Pressure 117 R W N Low Speed frequency Hz 1100 to rotational frequency setting win 120 default 1100 120 R W N Rotational freguency setting Hz Low speed freguency win 117 to 1350 default 1350 122 R W L Set vent valve on off on closed On 1 Off 0 default 1 123 Reserved to Agilent service 124 125 R W L Set the vent valve operation Automatic 0 see note 1 On command 1 see note 2 126 R W N Vent valve opening delay expressed in 0 2 0 to
198. ung der einschl gigen landes blichen Vorschriften erfolgen TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 35 297 2 Gebrauchsanleitung Entsorgung 36 297 Bedeutung des WEEE Logos auf den Etiketten Das folgende Symbol ist in bereinstimmung mit der EU Richtlinie WEEE Waste Electrical and Electronic Eguipment angebracht Dieses Symbol nur in den EU L ndern g ltig zeigt an dass das betreffende Produkt nicht zasammen mit Haushaltsm ll entsorgt werden darf sondern einem speziellen Sammelsystem zugef hrt werden muss Der Endabnehmer sollte daher den Lieferanten des Ger ts d h die Muttergesellschaft oder den Wiederverkaufer kontaktieren um den Entsorgungsprozess zu starten nachdem er die Verkaufsbedingungen gepr ft hat TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Fehlermeldungen Gebrauchsanleitung 2 In einigen St rungsf llen zeigt das Selbstdiagnosesystem des Controllers die in der nachstehenden Tabelle zusammengefa ten Meldungen an Tab 1 MELDUNG BESCHREIBUNG BEHEBUNG CHECK CONNECTION TO PUMP Fehlfunktion der Pumpen Controller Verbindung Oder Die Temperatur der Pumpe ist unter 0 C Sicherstellen da das Verbindungskabel zwischen Pumpe und Controller an beiden Seiten korrekt befestigt ist und keine Unterbrechung vorliegt Die Pumpe durch zweimalige Bet tigung der START Taste neustarten WAITING INTERLOCK Das Interlock Si
199. urnie par Agilent avant utilisation de appareil Agilent d cline par cons quent toute responsabilit en cas d inobservation totale ou partielle des instructions donn es utilisation incorrecte de la part un personnel non form op rations non autoris es ou un emploi contraire aux r glementations nationales sp cifigues Les contr leurs de la s rie TwisTorr 84 Rack sont des convertisseurs de fr guence contr l s par un microprocesseur r alis s avec des l ments a tat solide et ayant des capacit s autodiagnostic et autoprotection Caract ristigues du contr leur Caract re op rationnel de front distance s riel a Pilotage 24 Vdc du ventilateur de refroidissement pompe a Pilotage vent valve a Lecture vitesse pompe suite la commande d arr t lecture vitesse d arr t Lecture de la pression a Interface Profibus facultatif a Attribution automatique tension entr e Les paragraphes suivants donnent toutes les indications n cessaires garantir la s curit de l op rateur pendant l utilisation de appareillage Des renseignements plus d taill s se trouvent dans l appendice Technical Information TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Emmagasinage 3 Cette notice utilise les signes conventionnels suivants NAMES AIR Les messages d avertissement attirent l attention de l op rateur sur une proc dure ou une manoeuvre sp ciale qui si elle
200. us programmerbar analog utg ng Uttag 24 Vdc f r kylfl kt vent valve och manometer Inmodul f r styrenhet omfattande s kringar str muttag och ENG filter Vred f r inst llning av Profilbus adressen Profibus option Seriell kontakt f r fj rrkontroll CO N B GI B w Pumpkontakt 106 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Bruksanvisning 8 Instruktioner f r bruk Start av styrenheten Styrenheten startas enkelt genom att s tta str mkabeln i v gguttaget Start av pumpen Vid start av pumpen m ste ing ngen till interlock aktiveras och START knappen tryckas in p frontpanelen Stopp av pumpen Pumpen stoppas genom att trycka p tryckknappen STOPP p frontpanelen Underh ll Styrenheterna i TwisTorr 84 Rack serien r under h llsfria Allt servicearbete m ste utf ras av auktoriserad personal Om styrenheten havererar kontakta Agilent reparationsverkstad eller Agilent utbytesservice som kan ers tta styrenheten med en renoverad styrenhet VARNING Innan n got arbete utf rs p styrenheten m ste dess str mf rs rjning brytas Skrotning av pumpen ska ske enligt g llande lagstiftning TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 107 297 8 Bruksanvisning Bortskaffning 108 297 Betydelse av logotypen WEEE p etiketterna Symbolen som visas nedan har till mpats i enlighet med CD direkti
201. utside of the shipping box of your returning product o Clearly label package with RA number Using the shipping label provided will ensure the proper address and RA number are on the package Packages shipped to Agilent without a RA clearly written on the outside cannot be accepted and will be returned o Return only products for which the RA was issued Shipping o Ship to the location specified on the printable label which will be sent along with the RA number as soon as we have received all of the reguired information Customer is responsible for freight charges on returning product o Return shipments must comply with all applicable Shipping Regulations IATA DOT ADR etc and carrier reguirements RETURN THE COMPLETED REOUEST FOR RETURN FORM TO YOUR NEAREST LOCATION EUROPE NORTH AMERICA PACIFIC RIM Fax 00 39 011 9979 330 Fax Free 00 800 345 345 00 Fax 1 781 860 9252 Please visit our website for Toll Free 00 800 234 234 00 Toll Free 800 882 7426 Option 3 individual office information vpt customercare agilent com vpl ra agilent com http www agilent com Page 1 of 3 Agilent VPD Request for Return Agilent Technologies Vacuum Products Division Terms and conditions TERMS AND CONDITIONS Please read the terms and conditions below as they apply to all returns and are in addition to the Agilent Technologies Vacuum Product Division Products and Services Terms of Sale o Unless otherwise pre negotiated custome
202. v spajalni konektor ima ustrezen zapiralni mosti ek Konekotr logi nih izhodnih signalov in nadzor frekvence rpalke plus analogi ni izhod ki lahko programirate Izhodni napajalni konektor 24 Vdc za ohlajevalni ventil rpalke vent valve in kaliber Vhodni modul napajanje controller a ki vsebuje varovalke napajalno stikalo in filter ENC Rotacijski Switch za nastavljanje Profibusnega naslova Profibus kot opcija Serijski konektor za nadzor iz oddaljenosti il BR ew Konektor rpalke 190 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Priro nik za Navodila 15 Postopki uporabe Vklopitev Controllera Za vklopitev Controller a morate napajalni kabel vtakniti v omre no vti nico Zagon rpalke Da bi zagnali rpalko morate usposobiti vhod interlock a in pitisniti tipko START na prednji plo i Zaustavitev rpalke Zaustavite rpalko s tipko STOP na prednji plo i Vzdr evanje Controllerji serije TwisTorr 84 Rack ne potrebujejo vzdrZevanja Samo poobla eno osebje lahko rokuje s to napravo V slu aju okvare obrnite se servisu Agilent ali Agilent advanced exchange service ki Vam bo dal na razpolago obnovijeni controller SVARILO Pred katerikoli posegom izklopite iz controller a napajalni kabel Controller zavrzite kot industrijski odpadek v skladu z dr avnimi predpisi TwisTorr 84 FS AG Rack Controller User Manual 87 901 037
203. ve Vlow max 10v modes If active allows the pump running if Imax 5mA inactive stops the pump Imin on 2m A 4 com System Contact closed Active Optically isolated Active in all Override Contact open Inactive Vlow max 10v modes If active allows the pump running if Imax 5mA active stops the pump and all the Imin on 2mA others connected devices Fan Vent TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 215 297 17 Technical Information Pins Name Description Electrical Note Valve 5 com Soft Start Contact closed Active Optically isolated Active only in Contact open Inactive Vlow max 10v Remote Mode If active before the start command Imax 5mA operation and activates the spft start procedure Imin on 2m A in STOP To be used only at first pump run status up The following figure shows a typical contact logic input connection and the related simplified circuit of the controller Figure 10 Typical logic input connection J1 Output J1 OUT FEMALE CONNECTOR FAULT FAULT 24VDC R2 R2 24VDC START START 24VDC LOW SPEED LOW SPEED 24VDC R1 R1 24VDC PUMP CURRENT MONITOR 2V 1A PUMP FREQUENCY MONITOR SEE NOTE MONITOR COM PUMP FREQUENCY MONITOR 10V 56KRPM Figure 11 Logic output connector 216 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A TwisTorr 84 FS AG Rack Controller User Manu
204. vet som har betecknats som WEEE Den h r symbolen g ller endast i de l nder som tillh r den Europeiska Unionen indikerar att produkten p vilken symbolen har applicerats INTE f r skaffas bort tillsammans med vanliga hush lls eller industriavfall men att d remot ett differentierat uppsamlingssystem m ste uppr ttas Vi rekommenderar d rf r att slutanv ndaren tar kontakt med leverant ren av anordningen oberoende om det handlar om moderf retaget eller aterf rsaljaren f r att kunna starta uppsamlings och bortskaffningsprocessen detta efter limplig kontroll av kontraktsenliga tidsgr nser och f rs ljningsvillkor TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Felmeddelanden Bruksanvisning 8 N r vissa fel uppst r visar styrenhetens sj lvdiagnoskrets aktuellt felmeddelande p displayen De m jliga meddelandena listas i f ljande tabell Tab 1 MEDDELANDE BESKRIVNING TG RD CHECK Anslutningen mellan pump och Kontrollera att CONNECTION styrenhet r defekt anslutningskabeln mellan TO PUMP eller ocks pump och styrenhet r Pumpens temperatur ligger under 0 ordentligt monterad samt att oc inget avbrott f rekommer Tryck tv g nger p knappen START f r att starta om pumpen WAITING Interlock signalen finns p kontakt tg rda kortslutningen mellan INTERLOCK P1 p grund av kortslutning mellan stift 3 och stift 8 p kontakt P1 stift 3 och stift 8 i kontakten J1 eller s
205. vladani z eln ho panelu Stiskne li se jen jednou erpadlo pracuje rychlost stand by A stiskne li se je t jednou deaktivuje se zp sob LOW SPEED 3 Tla tko na piivolani parametru na displeji pump current pump power rotational speed temperatura spodn ho lo iska temperatura vrchn ho lo iska temperatura motoru frekvence indukce Nez visle od zvolen ho provozn ho zp sobu je neust le aktivn Jestli e se tla tka 3 a 1 stisknou spole n alespo na 2 vte iny bude aktivov n program dle kter ho se mohou naprogramovat n kter operativn parametry 4 Tla tko ovl d n START STOP RESET Je aktivn m jen po volb na eln m panelu Stiskne li se jen jednou spou t c f ze bude aktivov na jestli e se znovu stiskne erpadlo se zastav Jestli e se erpadlo automaticky zastav z d vodu n jak poruchy tla tko se mus napoprv stisknout aby se uskute nil reset kontrol ru a po druh aby se erpadlo znovu spustilo 5 Alfanumerick displej na tekut krystaly matice bod 2 linky x 16 charakter TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 165 297 13 N vod k Pou it ED OE Postava 3 Zadn panel Kontrol ru TwisTorr 84 AG Vstupn konektor logick ch sign l konektor spojky je dod v n s pr slu n m znovu z
206. vojan pistoke on irrotettava pistorasiasta Valvoja voidaan asentaa p yd n p lle tai siihen tarkoitukseen sopivan hyllyn sis n Joka tapauksessa huolehtikaa siit ett riitt v j hdytysilma p see vapaasti kiert m n laitteen sis ll lk asentako ja tai k ytt k valvojaa tiloissa joissa se joutuu alttiiksi ymp rist tekij ille sade j lumi p lylle sy vytt ville kaasuille r j hdysalttiissa ymp rist ss tai tiloissa joissa paloriski on suuri Toiminnan aikana tulee noudattaa seuraavia ymp rist olosuhteita koskevia s nt j l mp tila 5 C ja 45 C v lill a suhteellinen kosteus 0 95 v lill ilman lauhdetta Muiden kytkent jen ja valinnaisten lis laitteiden asennusten suorittamiseksi katsokaa kappaletta Technical Information TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 127 297 10 Ohjek sikirja K ytt T h n kappaleeseen on kirjattu t rkeimm t k ytt toimenpiteet Tarkempia lis tietoja sek kytkent j ja valinnaisia lis laitteita koskevien toimenpiteiden suorittamista k sittelevi tietoja l yd tte kappaleesta K ytt joka on Tekniset tiedot kappaleen liitteen Ennen valvojan k ytt suorittakaa kaikki s hk kytkenn t seuraten kytkett v n pumpun k ytt ohjeita VAROITUS Mik li pumppu on asetettu p yd lle varmistakaa ett se on vakaa N in v ltyt n vammoilta ihmisille sek itse konee
207. wisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Ohjekasikirja 10 Kaytt toimenpiteet Valvojan kaynnistys Valvoja k ynnistyy asetettaessa virtakaapeli pistorasiaan Pumpun k ynnistys K ynnist ksenne pumpun pit ottaa k ytt n interlock sis ntulo ja painaa etupaneelin painiketta START Pumpun pys ytt minen Huolto VAROITUS Pumppu pys htyy painettaessa etupaneelissa olevaa STOP painonappia TwisTorr 84 Rack sarjan valvojat eiv t kaipaa mink nlaista huoltoa Mahdolliset valvojaan teht v t toimenpiteet tulee j tt aina valtuutetun henkil n teht viksi Toimintah iri n sattuessa on mahdollista k ytt Agilentin korjauspalvelua tai Agilent advance exchange service palvelua jolloin on mahdollista vaihtaa rikkoontunut valvoja ladattuun valvojaan Ennen mink tahansa valvojaan teht v n toimenpiteen suorittamista irrottakaa s hk kaapeli pistorasiasta Mik li valvoja t ytyy romuttaa toimikaa sen h vitt misess kansallisten s d sten ja normien m r m ll tavalla TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 131 297 10 Ohjek sikirja H vitt minen Pakkausmerkinn iss olevan WEEE logon merkitys Alla n kyv merkki on lis tty pakkaukseen EY n ns WEEE direktiivin mukaisesti Merkki koskee ainoastaan Euroopan Unionin j senmaita tarkoittaa ett tuotetta El saa h vitt tavallisen kotitalous tai teollisuusj tteen
208. wrong parameter assignment B7 master_lock slave is parameterised by another master 1 Bo prm req slave has to be re parameterised Bi stat diag static diagnosis 2 Ba fixed 1 gt B3 wd on response monitoring active gt B Freeze mode received freeze command s Bs Synch mode received synch command E Be reserved CO B7 diag deactivated slave is parameterised by another master 2 Reserved 3 Master Add master address after parameterisation FF without parameter 4 Ident number high 5 Ident number low 6 External diagnosis Header length indication including header TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Technical Information 17 OFF SET MEANING 7 Interface Status Bo Controller not responds Bi Controller not identified B2 Input data not fully coherent yet B3 Not used R Baz Not used a 8 B74 Start Stop diag status gt B3 0 Low Speed diag status 9 B74 Soft Start diag status 5 B30 Vent Valve di 10 B74 Purge Valve B3 o Mode 11 B74 High speed B3 0 Low Speed TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 287 297 17 Technical Information Error Messages For a certain type of failure the controller will self diagnose the error and the following messages will be displayed If the pump is not connected the display will be as shown in the following figure CJH E C K CJO N NJE G T I O N T 0 PJUJM P
209. ych szczegolow skonsultowac odpowiedni rozdzial Technical Information Opis pulpitu frontalnego 1 3 2 4 Posta 2 Pulpit frontalny kontrolera TwisTorr 84 AG 1 Przycisk sluzacy do przywolania na display parametrow cycle number cycle time pump life 2 Przycisk do wybierania sposobu LOW SPEED Dziala tylko wtedy kiedy sposob sterowania jest wybierany na pulpicie frontalnym Naciskajac jeden szybkosc obrotu pompy w pozycji stand by Naciskajac jponownie nastepuje wylaczenie sposobu LOW SPEED ponownie 3 Przycisk sluzacy do przywolania na display parametrow pump current pump temperature pump power rotational speed Jest zawsze aktywny niezaleznie od wybranego sposobu dzialania Naciskajac jednoczesnie przyciski 3 1 przez conajmniej 2 secundy uruchamia sie program przy pomocy ktorego jest mozliwe programowanie niektorych parametrow operatywnych 4 Przycisk do przesylania sygnalu START STOP RESET Dziala tylko wtedy kiedy sposob sterowania jest wybierany na pulpicie frontalnym naciskajac jeden raz uaktywnia sie faza uruchomienia naciskajac ponownie zatrzymuje sie pompe Jezeli pompa zatrzyma sie automatycznie z powodu uszkodzenia nalezy nacisnac przycisk jeden raz zeby zresetowac kontrolera poraz drugi zeby uruchomic pompe 5 Display alfanumeryczny na cieklych krysztalach matryca punktowana 2 linie x 16 czcionek
210. yte 27 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A 281 297 17 Technical Information 5 1 Error Code bit field 206 B7 Too High Load the gas load is too high for the pump Bs Short Circuit a short circuit happened between the two of the three motor phases Bs Over Voltage too high bus voltage during braking Ba Verify Line Select Not used B3 Power Fail internal circuitry failure B2 Controller Over Temperature Controller Power Section Temperature or Controller CPU Section Temperature are over the limit B Pump Over Temperature Pump Bearing Temperature or Pump Body Temperature are over the limit Bo Check Connection To Pump the connection between controller and pump missing 6 1 Bo Set Point R1 Status 221 0 open 1 closed Bi Set Point R2 Status 225 0 open 1 closed B2 Vent Valve Status 122 0 closed 1 open Bs Purge Valve Status 145 0 close 1 open Ba Not Used Bs Not Used Be Not Used B7 Not Used 282 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Technical Information 17 7 mA 0 10000 Current 200 Motor current consumption 9 W 0 200 Power 202 Motor power adsorption 11 W 0 200 Power Limit Applied 155 Maximum allowable power 13 Hz 0 1500 Driving Freguency 203 Read the rotationa
211. z R JE ISIS JU R JE O VIE R Where PRESS OVER indicates that the pressure measured is above the maximum measurement threshold set 1000 mBar The unit of measurement of the pressure can be selected GAUGE menu Unit from mBar Pa torr Pressing 4 times returns to the following screen page N O IR MIA IL X X X X H z X IX X X X X X X XIX X X X TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Technical Information 17 Where NORMAL indicates the operating regime of the pump XXXHz see description Pressing once Measures key The operating mode of the controller is shown at the bottom in the center This may be FRONT front mode the controller accepts START STOP and LOW SPEED commands from the front panel REMOTE remote mode the controller accepts START STOP and LOW SPEED commands via the rear connector RS232 the controller accepts commands from the serial port according to the RS232 standard RS485 XX the controller accepts commands from the serial port in RS485 mode with address XX XX from 0 to 31 PROFIBUS YYY the controller accepts commands from the PROFIBUS port with address YYYY Black rectangles as shown below may be displayed at any time in the first and last box of the bottom line of the display opposite the LS AG R1
212. zijn meteen contact opnemen met het plaatselijke verkoopkantoor Zorg er bij het uitpakken voor dat de controller niet kan vallen of stoten te verduren krijgt Laat de verpakking niet ergens buiten achter Het verpakkingsmateriaal is volledig recyclebaar en voldoet aan de EEG milieurichtlijn 85 399 Figuur 1 Verpakking van de controllers 78 297 TwisTorr 84 FS AG Rack Controller User Manual 87 901 037 01 A Bedrijfshandleiding 6 Installatie De controller moet gevoed worden via een voedingskabel met drie draden zie tabel met bestelbare onderdelen met een stekker van het internationaal goedgekeurde type om de veiligheid van de gebruiker te waarborgen Gebruik altijd deze voedingskabel en steek de stekker in een geaarde contactstop om elektrische ontladingen te voorkomen en aan de CE specificaties te voldoen In de controller ontwikkelen zich hoge spanningen die zware beschadigingen of de dood kunnen veroorzaken Alvorens installatie of onderhoudswerkzaamheden uit te voeren de controller van de contactstop afkoppelen De controller kan op een tafel of in een speciaal rack worden geinstalleerd In ieder geval moet de koellucht vrij rondom het apparaat kunnen circuleren De controller mag niet geinstalleerd en of gebruikt worden in ruimten die blootgesteld zijn aan de weersomstandigheden regen vorst sneeuw stof agressieve gassen of in ruimten met ex plosiegevaar of zeer hoog brandgevaar Tijdens d
Download Pdf Manuals
Related Search
Related Contents
User Manual - Amazon Web Services Page 1 T。DAY 全建連 " H。U S ー NG (日召未ロ48年ー0月2。日第三 Zotac ZT-90103-10P NVIDIA GeForce GTX 970 4GB graphics card 光ポータブル 「PWR-Q200」 取扱説明書(PDF FAMIS User Manual - County of Sonoma CONFIGURING AND TROUBLESHOOTING A WINDOWS SEVER パソコン側での無線接続設定マニュアル Motion Activated Solar Powered LED Matrix Light User`s Manual - BCM Advanced Research De'Longhi AD679/699 User's Manual Copyright © All rights reserved.