Home
user manual
Contents
1. Check the L min setting To make black darker lower the value 7 2 Setup Problem Cause The Medivisor CD ROM is not inserted in the CD driver on your computer Solution Insert the Medivisor CD ROM in the CD drive on the computer and run setup exe from the CD See 2 2 for instructions Medivisor won t install The operating system doesn t meet the hardware requirements See 1 2 for the supported operating environments Proper operation is not guaranteed if they are not fulfilled You didn t accept the license agreement You must accept the License Agreement to install Medivisor 7 3 Test pattern Problem Solution The display color setting The gradation is is set to 8 bit color Check Display Properties gt Settings and change the color setting to 32 bit color not smooth The gamma setting was not appropriate Change the luminance and gamma settings if necessary and recalibrate the display TOTOKU ELECTRIC CO LTD 24 Uninstallation amp Troubleshooting 7 4 Auto Adjustment Problem Cause Solution If an error message appears in the wizard An error i rring i SOE OCCHI follow the instructions The calibration sensor is required for the following adjustments The calibration sensor is Only brightness A communication not connected or it is not Brightness and gamma error occurs connected properly Brightness and
2. 11 3 When the Setup Wizard appears click Next ill TOTOKU Medivisor for ME201L ME181L Welcome to the TOTOKU Medivisor for ME201L ME181L Setup Wizard ALI The installer will guide you through the steps required to install TOTOKU Medivisor for ME201L ME181L on your computer WARNING This computer program is protected by copyright law and international treaties Unauthorized duplication or distribution of this program or any portion of it may result in severe civil or criminal penalties and will be prosecuted to the maximum extent possible under the law installation select Agree and click Next i TOTOKU Medivisor for MEZO1L ME181L License Agreement Please take a moment to read the license agreement now If you accept the terms below click I Agree then Next Otherwise click Cancel Make sure to read this Software License Agreement before use Software License Agreement Please read this Software License Agreement Agreement thoroughly before using or installing Medivisor Grayscale By installing this software you are agreeing to be bound by the terms of this Agreement If you do not agree to this Agreement OI Do Not Agree gt Olare Cancel lt Back Installation 4 The License Agreement screen appears To accept the agreement and proceed with Important You must accept the agreement to complete installation of Medivisor for ME201L ME181L When the Select
3. Adhesive Gelatin Pad k IND AJJI NJ gt 1 2 Operating environment Computer IBM PC AT compatible machine 2 Microsoft Windows XP Professional SP1 or later Operating system Microsoft Windows 2000 Professional SP4 English Japanese CMCC o e kes Eig ME201L Series ME181L Series Language TOTOKU ELECTRIC CO LTD 8 Installation 2 Installation This chapter explains how to connect cables and install the hardware and software Make sure to log in as a user with administrative privileges registered with a local computer before starting installation 2 1 Connecting the cables Connect one end of the communication cable supplied with the display to display s PC LINK and the other end to the computer s serial port RS 232C For detailed information on other cable connections refer to the display user manual Computer aE To the Wall Outlet TOTOKU ELECTRIC CO LTD 9 Installation 2 2 Installing the calibration sensor driver 1 Connect the supplied calibration sensor DTP94 to the computer s USB port directiv or via a USB hub It will be detected as new hardware and the Found New Hardware Wizard starts up 2 Insert the supplied CD ROM Disk 2 in the CD drive on the computer Though the software installer starts up automaticallv go back to the Found New Hardware Wizard and select Install the softwa
4. TOTOKU User shall exercise the sole and proper control and supervision over any of their employees and hereby assumes full liability and responsibility of all obligations in connection with any party s employees and any activity of such employees in connection with Confidential Information Article 10 Limitation of Liability 1 To the maximum extent permitted by applicable law in no event shall TOTOKU or its distributor be liable for any special incidental indirect or consequential damages whatsoever including without limitation damages for loss of business profits business interruption loss of business information or any other pecuniary loss arising out of the use of or inability to use Software or failure to provide after sales services even if TOTOKU has been advised the possibility of such damages In any case TOTOKU s entire liability under any provision of this Agreement or Individual Contract shall be limited to the amount paid by User for the purchase of Software Software is not fault tolerant and is not designed intended or licensed for use in hazardous environments requiring fail safe performance such as in the operation of nuclear facilities aircraft navigation or communication systems air traffic control and life support or weapons systems in which the failure of Software could lead directly to death personal injury or severe physical or environmental damage hereinafter called as High Risk A
5. White pattern for Window Size manual adjustment The available sizes 5 10 default 15 20 and 25 of the pattern c m Changes the background brightness level of the Center Background White pattern to 0 black 20 default and 50 of 8 maximum luminance 3 All White Turns the Center White pattern into the All White pattern in O Return to Default Value Resets to factory default settings Change user To change the user password for this being password software Communication Setting for the To change the communication setting displav A Show display Displays the display ID in the upper right Sow cieee ID corner of the screen Switches display languages e Default tanataa e English guag e Japanese Default is English except when vour OS is in Japanese After switching to another language restart the software Brightness Unit To change the luminance unit between cd m2 and ft L Sensor Utilitv Zero calibrates the sensor Version Help Information Displavs the version information of this software TOTOKU ELECTRIC CO LTD 26 Appendix 8 2 Test patterns The Test Pattern button provides eight different test patterns The test patterns can be reversed into the negative images by selecting Patterns gt Reversed on the menu bar Button Pattern Explanation Useful to check Crosshatch e Linearity of vertical and horizontal lines e Misal
6. and 5 blacks The small square within the 0 black square should be visible Resolution Each line in vertical and horizontal stripes in the squares in the center and four corners should be distinguishable Linearity Check for distortion and misalignment using the grids across the screen Video Characteristics Check for streaking in and around the white and the black rectangles TOTOKU ELECTRIC CO LTD 29 Appendix 8 5 Attaching the calibration sensor 1 Peel the paper off the adhesive gelatin pad see the handling instructions below and stick the smooth surface on the back of the calibration sensor so that the rough surface will be exposed as shown below Peel the clear film off the rough surface Adhesive gelatin pad b Wy Calibration sensor ESS SS A gt X on the back side Z About the adhesive gelatin pad Please note the followings in handling the adhesive gelatin pad e The gelatin pad is double sided self adhesive and reusable e When adhesion is lost wash it with water or wipe it off with diluted mild detergent Do not rip it off Peel off slowly It is very stretchy e Keep it out of direct sunlight as it will degrade e Wipe the calibration sensor to remove dust and grease before sticking the gelatin pad to it e The gelatin pad is not food Do not lick or eat it Do not stick it on the human body 2 Run the calibration sensor s USB plug through the counterweight The counterwe
7. gamma Quick Connect the calibration sensor when making one of the above adjustments The calibration sensor is Attach the calibration sensor properly see not attached properly 18 5 lira kaw It is a feature of this It is a feature to reproduce correct colors g software and not a failure calibration 7 5 Manual adjustment Problem Solution The adjusted luminance won t stay applied The adjusted luminance Make sure to click Save data after may not be saved adjusting luminance TOTOKU ELECTRIC CO LTD 25 EU7um Appendix 8 Appendix 8 1 Menu items and hierarchv Test Pattern Displavs the test patterns 1 Auto Adjustment Adjusts the display automatically Manual Adjustment Manually adjusts luminance Exit Closes the software Cross hatching Displays the cross hatched pattern full screen Letter Displays a screen full of equally spaced letter E s Dots Displays a screen full of equally spaced dots Displays a white square in the center of the screen against Center White the black background Useful for calibration All White Displays plain white SUJ9JJEd 1S9L Gravscale Displavs shades of grav from black to white Displavs the SMPTE pattern usuallv used on medical SMPTE l image display devices Reversed Reverses the test patterns into negative images Resizes the white area of the Center
8. or using the spin buttons and click Next Automatic Adjustment 1 Automatic adjustment wizard nan aa Please inputtarget brightness 2 Input brightness data i 3 Gamma 4 Execute Cancel 2 The following screen appears at the end of the adjustment Click End to end the wizard Automatic Adjustment 1 Automatic adjustment wizard 1 Adjustment selection Complete adjustemt 2 Input brightness data Adjustment completed Please click End 3 Gamma 4 Execute gt End TOTOKU ELECTRIC CO LTD 21 Adjustment 4 4 Manual adjustment Luminance can be changed instantiv bv sliding the slider Note that gamma changes in concert with luminance However the method explained in 4 2 is recommended for more accurate results 1 Click the Manual Adjustment button in the adjustment menu area or select Adjustment Manual Adjustment on the menu bar 2 The Center White pattern automaticallv appears on the subject displav 3 Attach the calibration sensor to the center of the displav 4 Click Search Photometer and the calibration sensor gets detected and the current brightness value is measured automaticallv 5 Adjust luminance by dragging the scroll bar handle for Brightness 6 Click Save current value as Medivisor for ME201L ME181L Calibration Manual Option Help f e The Center White pattern mentioned in Step 2 can be customized see 5 2 e Luminance can be changed withou
9. the software for X Rite DTP34 Click Finish to close the wizard TOTOKU ELECTRIC CO LTD 10 Installation 2 3 Installing Medivisor for ME201L ME181L 1 If the Medivisor Installer is left open click Install Otherwise reinsert the CD ROM or run launcher exe on the CD ROM to start the installer and click Install E Medivisor Installer Disk 1 EJ Install Ej Medivisor Installer Disk 2 Calibration Software for Monochrome Display Medivisor Calibration Software for Color Display for i2 Series Veron Al Medivisor Color for CCL182 CCL202 CCL212 CCL316 CCL250i CCL350i Acceptance and Constancy Testing Softwar Version 2 1 Install Manual English Manual Japanese Medivisor Grayscale for ME213L ME3ISL MESIIL ME251i ME351i ME353i Version 3 Version 2 Displav Utilitv Softwar for i2 Series Medivisor for ME201L MEISIL Version Lil Version 21 fi d e o ji a ey Me IVISOr Calibration Software for Monochrome Displav Install Manual English Manual Japanese Calibration Software for Monochrome Displav Manual English Manual Japanese DICOM Conformance Test Software Install GSDF Checker for ME Series CCL Series i model Version L1 2 When the version information appears click Next Med visor for ME201L ME181L Manual English Manual Japanese TOTOKU ELECTRIC CO LTD
10. 1L has been successfully installed Click Close to exit TOTOKU ELECTRIC CO LTD 13 Initial Setu 3 Initial Setup Make sure to follow the instructions in this chapter upon initial use and after the display configuration has changed Otherwise calibration may not be carried out properly 1 Select TOTOKU Medivisor for ME201L ME181L gt Calibration from the Start menu 2 Select Option gt Monitor communication settings on the menu bar Medivisor for ME201L ME181L Calibration Display pattern Je User management Monitor communication settings Display monitor gt Language Luminance unit p m Sensor Utility 3 Select a serial port to use and click OK Communication Settings Please select a port a The currently used port will not be COM1 Under use shown COM Available Cancel 7 Show available ports only TOTOKU ELECTRIC CO LTD 14 Adjustment 4 Adjustment Before starting to use this software please close all other applications Calibrate displavs at least after 60 minutes of warm up time excluding the time during which the screen is blacked out because of the power save function or the screensaver Upon initial use in VGA mode and after changing the input timing on ME201L or ME181L adjust the display using the program called LCD Check supplied with the display prior to performing the adjustment explained in the following sections in this
11. Installation Folder screen appears select a destination folder Further down the screen is the setting as to where the shortcut to this software should be created To share it with all users of the destination computer select Everyone To use it by yourself select Just me and click Next i TOTOKU Medivisor for ME201L ME181L Select Installation Folder The installer will install TOTOKU Medivisor for ME201L ME181L to the following folder To install in this folder click Next To install to a different folder enter it below or click Browse Folder C Program Files TOTOKU Medivisor for ME201L ME181L Browse Install TOTOKU Medivisor for ME201L ME181L for yourself or for anyone who uses this computer O Everyone Just me Cancel lt Back By default the destination is C ProgramFiles TOTOKU Medivisor for ME201L ME181L TOTOKU ELECTRIC CO LTD 12 Installation 6 When the Confirmation Installation screen appears click Next to start installation ill TOTOKU Medivisor for ME201L ME181L Confirm Installation The installer is ready to install TOTOKU Medivisor for ME201L ME181L on pour computer Click Next to start the installation Cancel lt Back 4 7 When the Installation Complete screen appears click Close to complete installation Remove the CD ROM from the CD drive ill TOTOKU Medivisor for ME201L ME181L Installation Complete TOTOKU Medivisor for ME201L ME18
12. KU ELECTRIC CO LTD 18 Adjustment 5 Select a gamma curve Unless otherwise required select Barten and click Next Automatic Adjustment 1 Automatic adjustment wizard 1 Adjustment selection Please select gamma curve Barten curve C Exponential Value 2 Input brightness data 3 Gamma C Linear 4 Execute C Specified j End Back Cancel Type Explanation A commonly used DICOM compliant curve for medical image display Barten devices The DICOM standard curve was developed to match display output to the perceptual capabilities of the human visual system Exponential An exponential curve of y x Set a value for n Linear A linear curve of y nx Set a value for n User defined curve Hint User defined gamma can be created and modified using Sample usg located in the directory where this software is installed Open the file in a text editor and change values Specified 6 Attach the luminance sensor at the center of the screen and click Start Automatic Adjustment 1 Important Automatic adjustment wizard e Make sure to disable the power save function on the computer 1 Adjustment selection Start agjustment To stop the process press the ESC key on the keyboard or click 2 Input brightness data Execute adjustment Cancel on the wizard Otherwise each fie censor ie fe center ote do not touch the keyboard or use 3 Gamma After completed preparation please click
13. TOTOKU Monochrome Calibration Software Medivisor 4 for ME201L ME181L Medivisor for ME201L ME181L Contents Software License Agreement sseeenrennnnznnnnnnnnnzznnnnznnnnzznznzzzznzzznunzzminzzmnnzzmanzmnn 3 1 Introduction MA EMA EE HAmAHHAmAHnEmnnnmmnzzman 8 TA PACKAGES COMLEMUS asese nan dorsansssdseeauccnenteieadseansdeqsiendesocsneeaces sea 8 1 2 Operating environment nn nn n arr anna nanna anna n nn t 8 2 Installation see ee AM E 2 1 Connecting the cables 2 2 Installing the calibration sensor driver 2 3 Installing Medivisor for ME201L ME181L SIMIAN SOLU A 14 4 ACjUSTMENL 20 ceeceeeeseeseeeeseeeeeesseeeeeeseeesaeseaeeseesneesnneesaesenessaeseaessueveaesneevsneseneeeneneaess 4 1 Zero Calibration nn 4 2 Auto To li L 1 tkis aani odna eioi tia eaid peat 4 3 Brightness adjustment 4 4 Manual adjustment sssseennnnzznnnnzzznnnnnzzznnznzzzzzzzmrzzinztmrzaiiittzzzzizzzrmzzzzzzzzazi 5 Other FUNCtIONS ccecceeeeeseeeeeeneeeeseeeeseeeeseeeeneeeeaeeaeeeneaeeseeeeseeaeseeeeseeaeessaesesensesnnaeas 23 5 1 Setting up a user password snanar nanna anna 23 5 2 Customizing the Center White pattern sssssesnssnennnznzznnnzzznnnnnzzznnnnenzznzzn 23 6 Uninstallationc i easier ele ade a ees 24 7 Troubleshooting 7 1 General 7 2 SetUp 7 3 Test pattern 7 4 Aut
14. agement Monitor communication settings Display monitor gt Language gt Luminance unit La S Jtility Se f Q 2 2 When the Sensor Utility appears click Search the Sensor DTP94 will be detected Sensor Utility CSearch sensor Ja DTP94 Get luminance Zero Calibration 3 Lay the calibration sensor down on an even surface so that no light leaks into the light sensitive area and click Zero Calibration When OK appears zero calibration is done rr wre Sensor Utility ii Search sensor DTP34 Get luminance To check the result of zero calibration click Get luminance Gero Calibration gt OK OK TOTOKU ELECTRIC CO LTD 16 Adjustment 4 Click OK to complete zero calibration Sensor Utility Search sensor DTP94 Zero Calibration OK 4 2 Auto Adjustment 1 Click the Auto Adjustment button in the adjustment menu area or select Adjustment gt Auto Adjustment on the menu bar 2 Select a display to calibrate in the Display Icon Area and click Start Start automatic adjustment Select the target monitor and click Start button When make other adjustment click other adjustment button Medivisor for ME201L ME181L Calibration Option Help TOTOKU ELECTRIC CO LTD 17 Adjustment 3 The Auto Adjustment Wizard appears Select Brightness and gamma adjustment and click Next Automatic Adjustment 1 Automatic adjus
15. chapter Otherwise proper calibration may not be carried out For detailed instructions see the display user s manual The adjustment using LCD Check is not necessary when ME201L and ME181L are used in DVI mode The screen consists of the following three sections ar Medivisor for ME201L ME181L KI Eal Adjustment Menu Area libratiqg Displ tte Opti Help f Contains adjustment buttons See the table below for more information Display Icon Area Contains the same number of display icons as connected displays Use the icons to select displays Adjustment Status Area Shows related information and l control buttons for the selected adjustment In this example the l Test Pattern button is selected and l all available patterns are shown J Button Name Explanation 7 met 5 7 7 Test Pattern Displays test pattern icons For more information ma see 8 2 g Auto Adjustment Automatically calibrates the display or Manual Adjustment Manually adjusts luminance TOTOKU ELECTRIC CO LTD 15 Adjustment 4 1 Zero calibration Calibrate the luminance sensor zero calibration before starting adjustment Zero calibration is to get the sensor recognize the darkest black If it is not carried out properly a margin of error increases 1 Select Option gt Sensor Utility on the menu bar sr Medivisor for ME201L ME1B1L Elem Calibration Display pattern Kesta Help User man
16. ctivities Without limiting the generality of the foregoing TOTOKU specifically disclaim any express or implied warranty of fitness for High Risk Activities TOTOKU ELECTRIC CO LTD 5 Medivisor for ME201L ME181L Article 11 Export Regulations User mav take Software outside of its own countrv subject to the prior written consent of TOTOKU In the case of foregoing User shall at its own cost and responsibilitv complv with all relevant export laws and regulations of its own country hereinafter called as Export Laws to assure that neither Software nor any related program thereof are 1 exported directly or indirectly in violation of Export Laws or 2 are intended to be used for any purposes prohibited by Export Laws including without limitation nuclear chemical or biological weapons proliferation Article 12 Taxes User shall be solely responsible for and shall pay or reimburse TOTOKU for all taxes duties assessments and other governmental charges which are now or hereafter imposed by governmental authority associated with the performance of TOTOKU s obligations under this Agreement Article 13 Duration 1 This Agreement comes into force on the date first written and unless sooner terminated shall continue in effect for a period of one 1 year Provided however that in case the parties hereto agreed to the terms and conditions in respect of the renewal or extension of this Agreement in writing prior to t
17. e that any software made by the third party is included in Software the provisions of the user software license agreement between User and the third party shall be applied in respect of such software 3 TOTOKU DOES NOT MAKE AND HEREBY DISCLAIMS ANY WARRANTY IN RESPECT OF SOFTWARE OTHER THAN AS PROVIDED ABOVE IN THIS ARTICLE WHETHER EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PURPOSE Article 8 Intellectual Property Right 1 User acknowledge that all patents designs copyrights know how and other intellectual property rights used or embodied in connection with Software are the exclusive properties of TOTOKU and shall not dispute them for any reason whatsoever User shall not apply for or register any intellectual property right in connection with Software TOTOKU ELECTRIC CO LTD 4 Medivisor for ME201L ME181L User herebv agree to advise TOTOKU immediatelv after User becomes aware that anv intellectual propertv right in connection with Software is attacked or infringed upon by any third party In the case of aforesaid attack or infringement User shall cooperate with and aid TOTOKU for the defense proceedings at its own cost and TOTOKU shall retain all rights to control the direction of any action thereof To the best knowledge of TOTOKU Software will not infringe upon any intellectual property right of any third party Notwithstanding the foregoing in th
18. e case of any claim of infringement or alleged infringement of intellectual property rights brought by third parties in relation to Software User shall advise cooperate with and aid TOTOKU for the defense proceedings at its own cost and TOTOKU shall retain all rights to control the direction of any action thereof In case that Software is held or believed by TOTOKU or any court of competent jurisdiction to infringe any intellectual property right of any third party TOTOKU shall have the option at its expense to a modify Software to be non infringing or b obtain a license for User to continue the deal of Software If it is not commercially reasonable to perform either of the above options then TOTOKU may terminate the license for the infringing Software and refund the license fees paid for Software to User less the reasonable value received by User to the date of the aforesaid termination Article 9 Confidential Information ts User shall not disclose to third parties any information which is confidential and proprietary in nature of TOTOKU in respect of Software Such confidential and proprietary information hereinafter called as Confidential Information includes but not limited to trade secrets know how inventions patents techniques processes programs schematics data User agree that Confidential Information shall be kept confidential and shall not be disclosed to any other party without the written consent of
19. he expiration of the term hereof this Agreement shall be renewed or extended for the term agreed upon 2 In the event of expiration of this Agreement the parties hereto shall have no claim against the other party for the loss of good will or future profit Article 14 Termination TOTOKU may without prejudice to any other rights or remedies terminate this Agreement or Individual Contract if the User fails to perform any provision of this Agreement or Individual Contract Article 15 Effect of termination If this Agreement is expired or terminated under the terms and conditions herein the parties hereto shall comply with the followings 1 The license granted hereunder shall terminate 2 User shall return to TOTOKU Software together with all copies in all forms and whether partial or complete on all types of media and computer memory and whether or not modified or merged into other material 3 User shall delete or remove Software and any such source code from all workstation and or terminal pursuant to TOTOKU s directions Article 16 Damages If TOTOKU was damaged or injured due to User s breach or default of any provision hereof or by the termination specified at the subparagraph from 1 to 5 in Article 14 TOTOKU may claim User damages thereof Article 17 Survival Article 8 Intellectual Property Right and 9 Confidential Information of this Agreement shall survive the termination or expiration here
20. ich shall set forth terms and conditions including but not limited to a identification of Products including model numbers b quantity c requested shipping date from Japanese port d price e payment f shipping instructions and shipping address Article 2 Order of Precedence The terms and conditions of this Agreement shall govern Individual Agreement In case that terms and conditions of Individual Agreement is inconsistent or conflict with the provisions of this Agreement the provisions of this Agreement shall prevail Article 3 Grant of License 1 TOTOKU hereby grants to User and User accepts non exclusive and non transferable license to use install and copy Software under this Agreement 2 User shall use Software solely on its computer of the same number as the number of licenses User shall not sublicense rent or lease Software or use Software for third party training commercial time sharing or service bureau use 3 The aforesaid license granted is solely for User s operations on the designated system Article 4 Limitations on License 1 User shall not cause or permit to any third party the reverse engineering discovering the source code disassembly modification update customization or recompilation of Software 2 User shall not use or cause to be used license granted herein and for any purpose whatsoever other than for the purpose specified in this Agreement 3 TOTOKU shall retain all title cop
21. ight is oval shaped with one end being narrower than the other Put the USB plug through the smaller opening first and then run it through the bigger opening so that the wider end comes on the bottom when it is hung ON sensor LL LCD Pal Side view S TOTOKU ELECTRIC CO LTD 30 Appendix 3 Attach the calibration sensor to the center of the measuring area by adjusting the position of the counterweight on the cord Be careful not to damage the panel surface with either the calibration sensor or the counterweight Keep the LCD panel at the same tilt angle as it is in use Do not further tilt or straighten the panel for calibration 8 6 Version information 1 Select Help gt Version Information on the menu bar and the version information screen appears A Medivisor for ME201L ME181L version information B The display firmware version information About TOTOKU COPYRIGHT 2000 2007 TOTOKU ELECTRIC CO LID ME181L ir MDL1 809AR CCL202R CALIBRATION BOARD VER2 00 2006 02 02 ABC State Type 1 1 2 Click OK to close the screen TOTOKU ELECTRIC CO LTD 31 TOTOKU Medivisor for ME201L ME181L Ver 3 0 User s Manual January 2007 Edition PZZ11 1069C Notes for the User s Manual e No part of this manual whether partly or wholly may be reproduced or copied without authorization e The content of this manual is subject to change without notice e Although this manual has been prepa
22. ignment of colors on color displays Character Useful to check the focus E Dot Useful to check the focus L 1 Center White Useful to check brightness All White Useful to check color and luminance uniformity Gravstal Useful to check for a smooth transition of gradations y from black to white see 8 3 SMPTE eae used on medical image display devices see TOTOKU ELECTRIC CO LTD 27 UA0U0 Appendix 8 3 Gravscale pattern The gravscale pattern consists of 3 horizontal sections containing grav levels from black 0 to white 255 Each section is further divided into 17 cells The table below shows what gravscale level each cell represents Gravscale Pattern 239 240 241 re 254 255 0 16 32 F 240 255 0 1 2 Siy 15 16 Top Gray levels from 239 to 255 in increments of 1 Middle Black 0 to white 255 in increments of 16 Bottom Gray levels from 0 to 16 in increments of 1 TOTOKU ELECTRIC CO LTD 28 Appendix 8 4 SMPTE pattern lil ARS y 77 ili 5 Black jum O mT TTT TTT Ty fi Grayscale The middle section of the pattern contains gray levels from 0 to 100 in increments of 10 You can check the smoothness or continuity of grayscale Check to see if there is e Clear distinction between 100 and 95 whites The small 95 square within the 100 white square should be visible and e Clear distinction between 0
23. o Adjustment 7 5 Manual adjustment 8 Appendix ee eee MAMMA HHH ntrama nmnntmnz 8 1 Menu hierarchv 8 2 Test patterns 8 3 Grayscale Pate Misc cscs store seadccnes secede seee ENO TEn ATELE TEREE TEE S ENN 8 4 SMPTE Patterns is cscccses ca docssssacndssvecscsssesnsssacasedacecessnce finan sasteaecdaius EA EEEE seats 8 5 Attaching the calibration sensor 8 6 Version information s s i serati Rede debate dead TOTOKU http www totoku com display Copyright C 2000 2007 TOTOKU Electric Co Ltd All rights reserved TOTOKU ELECTRIC CO LTD 2 Medivisor for ME201L ME181L Make sure to read this Software License Agreement before use Software License Agreement Please read this Software License Agreement Agreement thoroughly before using or installing Medivisor for ME201L ME181L By installing this software you are agreeing to be bound by the terms of this Agreement If you do not agree to this Agreement return the entire package with all of its contents along with the purchase receipt to the place of purchase for a full refund Article 1 Definition 1 Software identified above hereinafter called Software includes documents such as manual and specifications etc media any software and such products delivered by TOTOKU from time to time under this Agreement 2 Individual Contract means the agreement to be concluded in the form of purchase order wh
24. of Article 18 Severability If anv provision of this Agreement is held bv a court of competent jurisdiction to be illegal or invalid the remaining provisions hereof shall remain effect TOTOKU ELECTRIC CO LTD 6 Medivisor for ME201L ME181L Article 19 Force Majeure Neither parties hereto shall be liable for any delay or failure to perform any of its obligations hereunder other than the obligation to make any payment which is due if such delay or failure is due to fire flood earthquake epidemic unusually severe weather strike act of God or public enemy public disorder restriction by civil or military authority in their sovereign or contractual capacities transportation failure or any other cause beyond the reasonable control of the parties Article 20 Assignment and Delegation Neither whole of this Agreement nor any part hereof shall be assignable or delegable by any party hereto without other parties prior written consent which shall not be unreasonably withheld In the event of such assignment or delegation the assigning or delegating party shall remain liable to the other parties and shall not be relieved of any obligation under this Agreement Article 21 Waiver Failure by any party to require performance by the other parties or to claim a breach of any provision of this Agreement shall in no manner be deemed to be a waiver of such provision or right on any other occasion Article 22 Arbitra
25. re automatically Recommended and click Next Found New Hardware Wizard Welcome to the Found New Hardware Wizard This wizard helps you install software for X Rite DTP34 If your hardware came with an installation CD E or floppy disk insert it now What do you want the wizard to do Install the software automatically Recommended O Install from a list or specific location Advanced Click Next to continue Figures used in this manual are of Windows XP Screens on your display may appear different according to the operating system The Medivisor for ME201L ME181L Installer can be closed or left open 3 The following screen may appear Click Continue Anyway to proceed with installation Hardware Installation The software you are installing for this hardware X Rite DTP34 has not passed Windows Logo testing to verify its compatibility with Windows XP Tell me why this testing is important Continuing your installation of this software may impair or destabilize the correct operation of your system either immediately or in the future Microsoft strongly recommends that you stop this installation now and contact the hardware vendor for software that has passed Windows Logo testing STOP Installation 4 Click Finish to complete installation Found New Hardware Wizard Completing the Found New Hardware Wizard The wizard has finished installing
26. red carefully please let us know if you find any errors omissions or ambiguous explanations TOTOKU TOTOKU ELECTRIC CO LTD 1 3 21 OKUBO SHINJUKU KU TOKYO 169 8543 JAPAN TEL 81 3 5273 2005 FAX 81 3 5273 2091 URL http www totoku com display PZZ11 1069C Medivisor for ME201L ME181L 070131
27. s level of the dark area can be changed to 0 pitch black 20 default and 50 Select Manual Brightness gt Background on the menu bar All white The Center White pattern can be turned into the All White pattern Select Manual Brightness gt All White on the menu bar e To default Select Manual Brightness gt Return to default value to reset to default settings TOTOKU ELECTRIC CO LTD 23 Uninstallation amp Troubleshooting 6 Uninstallation To uninstall Medivisor for Medivisor for ME201L ME181L select Control Panel gt Add Remove Programs from the Start menu and remove TOTOKU Medivisor for Medivisor for ME201L ME181L After uninstallation the TOTOKU Medivisor for Medivisor for ME201L ME181L folder may remain in the directory where it was installed Delete the folder manually 7 Troubleshooting 7 1 General Problem Cause The communication cable is not connected Solution Connect the communication cable see 2 2 The communication cable is not correctly connected A communication error occurs Refer to the display user s manual and 2 1 and check if the connections are correct Another application is running A communication error may occur when other application is running Shut down all the other applications The display has not Black isn t been calibrated Calibrate the display dark enough It appears gray The L min value is set high upon calibration
28. t using the calibration sensor Steps 3 and 4 can be skipped However accurate adjustment cannot be achieved Brightness Current Brightness TOTOKU ELECTRIC CO LTD 22 Other Functions 5 Other Functions 5 1 Setting up a user password Setting up a user password limits the access to the software 1 Select Options gt User settings gt Change user password on the menu bar 2 When setting a password for the first time enter the password twice in the bottom half of the screen and click OK Change password Advanced user Please enter current password e There is no limit to the length ofa ING password or expiration date e Write down the password in case Please enter new password 2times you forget it And keep it in a secure place C o JI Cancel Once a user password is set the login screen appears every time TOTOKU Medivisor for ME201L ME181L gt Calibraton is selected from the Start menu Enter the password and click OK to log in Please input password password CO oma 5 2 Customizing the Center White pattern The Center White pattern that appears during manual adjustment can be customized Windows size When resolution scaling of the subject displav is 1 1 the size of the white area measuring area can be resized into 5 10 default 15 2090 and 25 of the test pattern Select Manual Brightness gt Window size on the menu bar e Background brightness The brightnes
29. the after sales agreement between User and TOTOKU or TOTOKU s distributor Article 7 Warrantv 1 Program Warrantv 1 TOTOKU warrants that Software will perform the functions described in its manual and or specifications during the term of this Agreement unless a Software is modified disassembled or customized bv the parties other than TOTOKU b Software is operated in combinations other than as specified in its manual and or specifications In addition TOTOKU shall make its best efforts to make Software free from program error Provided however that TOTOKU shall not warrant that Software is error free and uninterrupted 2 In the case of breach of the foregoing warrantv TOTOKU shall make its best efforts to correct the defect or program errors bv providing updated or amended version of Software In case TOTOKU cannot correct the defect or program errors TOTOKU may at its option terminate this Agreement and any payment previously made to User by TOTOKU will be refunded less the reasonable value received by User of the use of Software to the date of the aforesaid termination 2 Media Warranty 1 TOTOKU warrants that CD ROM or other media for Software is free from defects in materials and workmanship under normal use for fourteen 14 days from the date of delivery 2 In the case of breach of the foregoing warranty TOTOKU shall replace or repair the defective media accordingly Notwithstanding the aforesaid warranty in cas
30. the mouse Accurate results may Start agiustmant button not be obtained otherwise 4 Execute Cancel TOTOKU ELECTRIC CO LTD 19 Adjustment When an error occurs an error message appears on the wizard Follow the on screen instructions To retry the adjustment click Retry To cancel it click Cancel Automatic Adjustment 1 Important Automatic adjustment wizard Check the followings as well e Is the calibration sensor properly placed in the center of the display For adjustments that require the 2 Input brightness data Ireagal data from the sensor Sensor may calibration sensor be mis mounted 1 Adjustment selection Error e Are the computer and the display 3 Gamma connected with the serial signal cable RS 232C e Is the serial cable connected to the right port on the display Make sure PC LINK and SENSOR are not mixed up 4 Execute C S 7 The following screen appears at the end of the adjustment Click End to end the wizard Automatic Adjustment 1 Automatic adjustment wizard 1 Adjustment selection Snoen 2 Input brightness data Adjustment completed Please click End 3 Gamma 4 Execute P End TOTOKU ELECTRIC CO LTD 20 _ Adjustment 4 3 Brightness adjustment 1 When only brightness adjustment is selected at Step 3 in the previous section the following screen appears Set the maximum luminance by directly entering the value
31. tion All disputes controversies or differences that may arise between the parties hereto out of or in relation to or in connection with this Agreement or the breach hereof which have not been settled by mutual consultation shall be finally settled by the arbitration The arbitration shall be held in Tokyo Japan in accordance with the Commercial Arbitration Rules of The Japan Commercial Arbitration Association The award to be rendered shall be final and binding upon the parties hereto Judgment upon such award may be entered in any court having jurisdiction thereof Article 23 Governing Law This Agreement shall be governed and construed in accordance with the laws of Japan Article 24 Entire Agreement This Agreement constitutes the entire and only agreement between the parties hereto and supersedes all previous negotiations agreements and communications with respect hereto and shall not be released discharged changed or modified in any manner except by instruments signed by duly authorized officers or representatives of each of the parties hereto TOTOKU ELECTRIC CO LTD 7 Introduction 1 Introduction Medivisor for ME201L ME181L is a calibration software designed to calibrate the TOTOKU ME201L and ME181L Series monochrome displays 1 1 Package contents This product package contains the following items If anything is missing please contact your dealer Medivisor CD ROM Calibration Sensor DTP94 Counterweight
32. tment wizard L gt Daien Please select adjustment items 2 Input brightness data Only brightness adjustment 3 Gamma Brightness and gamma adjustment 4 Execute c Brightness and gamma adjustment Quick e Though there are 3 adjustment tvpes perform regular calibration Brightness and gamma adjustment for initial adjustment e The Quick adjustment proceeds the same way as the regular above adjustment except that the number of luminance measuring points are only half of the above requiring less time For more accurate result select the regular adjustment e See 4 3 for instructions on the brightness adjustment 4 Set maximum and minimum luminance and ambient light by directly entering values or using the spin buttons and click Next Automatic Adjustment 1 Automatic adjustment wizard il Adjusiment selection Please input target brightness 2 Input brightness data L max cdm L min cdim 2 3 Gamma H Ambient 0 edim 2 4 Execute Use current brightness after End measurement e L max Maximum luminance Set this to the default 410 cd m unless otherwise necessary e L min Minimum luminance Set this to 0 0 cd m e Ambient Enter a value only if it is known otherwise leave it as is e Use current brightness after measurement When checked current measured maximum and minimum luminance values are applied The above settings become invalid and locked TOTO
33. yright and other proprietary rights in Software User shall not acquire any right express or implied in Software other than those specified in this Agreement Article 5 Management of Software 1 Subject to the terms and conditions hereunder User may copy Software for archival and backup purposes and agree to label all such copies with the copyright notice designated by TOTOKU User shall manage the copy of Software with the duty of care and diligence of a good manager and upon TOTOKU s request shall make a written report to TOTOKU in respect of Software copied TOTOKU ELECTRIC CO LTD 3 Medivisor for ME201L ME181L 2 At TOTOKU s written request User shall furnish TOTOKU with a signed certification verifving that Software are being used pursuant to the provisions of this Agreement TOTOKU reserves the right at anv time to inspect Software at the business premises of User during the term of this Agreement to insure and maintain the qualitv and efficient management of Software In case the aforesaid inspection reveals that User has underpaid fees to TOTOKU User shall be invoiced for such underpaid fees with penaliv 3 User mav change its computer where Software is to be installed in subject to prior written consent of TOTOKU Article 6 After Sales Service After sales service such as replv to inquirv technical support training and consulting service for Software shall be provided by TOTOKU or TOTOKU s distributor under
Download Pdf Manuals
Related Search
Related Contents
〇足場板は、正しく使われていないと 転慣ーや転落の危険カ離あります notice technique spa aqualux GENÈSE 2.4-8, 18-25 L`ORIGINE DU COUPLE ET DE LA User Manual E-3 Sony KDL-46XBR2 User's Manual Heurtin Jean-Philippe_liste publications - lier Simpson Strong-Tie STCT Installation Guide 洗面化粧台『スーリア』 User Manual SCOUT Copyright © All rights reserved.