GT12 User`s Manual
Contents
1. 175 5 6 91 0 39 0 0 39 222 8 74 BSS 288 11 34 54 201 52 2 05 58 2 28 53 2 09 226 8 90 Unit mm inch Unit mm inch 5 EMC AND LOW VOLTAGE DIRECTIVE For the products sold in European countries the conformance to the EMC Directive which is one of the European Directives has been a legal obligation since 1996 Also conformance to the Low Voltage Directive another European Directives has been a legal obligation since 1997 Manufacturers who recognize their products must conform to the EMC and Low Voltage Directive are required to declare that their products conform to these Directives and put a CE mark on their products Authorized representative in Europe Authorized representative in Europe is shown below Name _ Mitsubishi Electric Europe BV Address Gothaer strase 8 40880 Ratingen Germany 5 1 Requirements to Meet EMC Directive EMC Directives are those which require any strong electromagnetic force is not output to the external Emission electromagnetic interference and It is not influenced by the electromagnetic wave from the external Immunity electromagnetic sensitivity Items5 1 1 through5 4 3 summarize the precautions to use GOT and configure the mechanical unit in order to match the EMC directives Though the data described herein are produced with our best on the bas
2. For grounding with cable clamps Refer to Section 5 4 3 a For RS 232 cable GOT side PLC side Oi y m MO 230 or less 9 06 lader s7 Unit mm inch b For RS 422 cable GOT side PLC side p L 230 or less 9 06 40 1 57 Unit mm inch 2 Ethernet connection Strip the outer insulation layer at both ends of the cable by the length shown below to expose the braided shield for grounding For grounding with cable clamps refer to Section 5 4 3 Attach the ferrite core to the cable in the position as illustrated below GOT side _ Ferrite Core ZCAT3035 1330 PLC side a 120 orlless 4 72 lao 400 or less 15 75 230 or less 9 06 40 1 57 1 57 Unit mm inch 3 When connecting to PLC manufactured by other company microcomputer temperature controller inverter servo amplifier CNC MODBUS R RTU or MODBUS R TCP connection Produce the cable RS 232 cable RS 422 cable for connecting the GOT to a controller with reference to the GOT1000 Series Connection Manual Configure the system to meet the EMC Directive specifications for the connected device when connecting the GOT to a controller The following gives the instructions to ensure the machinery comply with the EMC Directive However the manufacturer of the machinery must finally determine how to make it comply w
3. screw GOT1000 Series Gateway Functions Manual section SH 080858ENG grade font for GT Works3 7 A na i Other Sold separately 1D7MA7 Provides high speed monitoring through high speed than the 4 2 2 For GOTs powered from the 24VDC power GTSi D communication at maximum of 115 2kbps for the serial genly supply i Pores Version Operating Manual SH 080861ENG communication and 100Mbps for the Ethernet communication Storage ambient SETS o bbe Sold separately 1D7MB1 Provides high speed display and high speed touch switch temperature 20 to 60c GTISTE VNED GTIZ5NNBD response Operating ambient 40 to 90 RH non condensin Input power supply voltage DC24V 25 20 7 i ral vas P GoTo pi a enana SH 080863ENG The operation performance is improved by the analog touch i Power consumption TIW or less unctions Option ae id a S2 1D7MB3 panel a Rem 10 to 90 RH non condensing When backlight is not lit 6W or less a ki separately 2 More efficient GOT operations including screen design startup Accele Half Sweep Inrush current 29A or less 10ms maximum load GT12 Supplementary Description 5H 080864ENG adjustment management and maintenance works Frequency ration __ amplitude count Allowable momentary power 49 ms or less Sold separately 1D7MB7 9MB user memory is included as stan
4. Version 1 00A or later English version Version 1 01B or later GT Designer2 Japanese version Version 2 25B or later English version Version 2 27D or later 2 When the file number is between 90 and 100 the system signal 2 1 b12 hard copy auxiliary signal turns on The signal notifies that the number of files in a CF card has reached almost the maximum 100 4 GT Designer3 comparison The following shows the differences in settings for GT Designer3 on the GT12 and the GT11 When designing GT12 screens BMP and JPEG format files can be used for parts display and parts movement images Item Relevant manual Model GT12 V 640x480 GT11 Q 320x240 Setting i A Model installation Horizontal and vertical option not Horizontal and vertical option available GOT type een available setting direction Color setting 256 colors Monochrome 16 adjustment level 256 colors Screen Design Manual Fundamentals Standard I F RS422 485 Standard I F RS422 232 CH1 VF Standard I F RS232 Standard I F RS232 Connection Standard I F Ethernet device setting Standard I F RS422 485 CH2 VF Standard I F RS232 I F none Standard F Ethernet 5 GT Simulator3 comparison The following shows the differences in functions for GOT1000 series GT12 simulator and GOT1000 series GT11 simulator on GT Simulator3 To use the GT12 simulation functions on GT Simulator3 select GOT1000 series GT12 simulator in the main menu dialog box
5. a aMITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN NAGOYA WORKS 1 14 YADA MINAMI 5 CHOME HIGASHI KU NAGOYA JAPAN When exported from Japan this manual does not require application to the Ministry of Economy Trade and Industry for service transaction permission Specifications subject to change without notice Printed in Japan May 2011
6. remains active This may confuse an operator in thinking that the GOT is in screensaver mode who then tries to release the GOT from this mode by touching the display section which may cause a touch switch to operate Note that the following occurs on the GOT when the backlight goes out The POWER LED flickers green orange and the monitor screen appears blank The display section of the GT12 is an analog resistive type touch panel If you touch the display section simultaneously in 2 points or more the switch that is located around the center of the touched point if any may operate Do not touch the display section in 2 points or more simultaneously Doing so may cause an accident due to incorrect output or malfunction When programs or parameters of the controller such as a PLC that is monitored by the GOT are changed be sure to reset the GOT or shut off the power of the GOT at the same time Not doing so can cause an accident due to false output or malfunction Do not bundle the control and communication cables with main circuit power or other wiring Run the above cables separately from such wiring and keep them a minimum of 100mm apart Not doing so noise can cause a malfunction Do not press the GOT display section with a pointed material as a pen or driver Doing so can result in a damage or failure of the display section When the GOT is connected to the Ethernet network the available IP address is restricted according
7. 2 a D7MB9 NION A Akt aori ee aay CF card interface For installing a CF card Input power supply voltage AC100 to 240VAC 10 15 Sold separately 4 Option functi ilabl ihe Standard CF card access LED EA lit ce card accessed a Input frequency 50 60Hz 5 i ii i ion functions available on the standar 7 GT Designer3 Version Screen Design SH 080867ENG 1 Op e 5 A Used for accepting or stopping the access to the CF card Input max apparent power 44VA maximum load Manual Functions 1 2 2 2 1D7MC1 No option function board is required for using the option functions before removing the CF card from the GOT Sold se 4 CF card access switch iad Power consumption 18W or less parately 2 Large model line up ON_ CF card being accessed CF card removal prohibited i GOT1000 Series Connection Manual SH 080868ENG For screen sizes there is a 10 4 type for the GT1675 and an 8 4 na a accessed CF card removal possible Whenibacidight Is ntl w um i 5 ase a attery holder louses the battery Inrush current 40A or less 4ms maximum load Mitsubishi Products for GT Works3 4 1D7MC2 type for the GT1665 available for large models Terminating resistor A inati i Allowable momentary power Sold separately 3 Expanding user memory setting switch par ares on and off of the terminating resistor for the allure tine 20 ms or less AC 100VAC or more GOT1000 Series Connection Manual On the GT11 the capacity for the user memo
8. TEL 33 1 5568 5568 South Africa Circuit Breaker Industries Ltd Private Bag 2016 ZA 1600 Isando South Africa Tel 27 11 928 2000 Hong Kong Mitsubishi Electric Automation Hong Kong Ltd 10th Floor Manulife Tower 169 Electric Road North Point Hong Kong Tel 852 2887 8870 China Mitsubishi Electric Automation China Ltd 4 F Zhi Fu Plazz No 80 Xin Chang Road Shanghai 200003 China Tel 86 21 6120 0808 Taiwan Setsuyo Enterprise Co Ltd 6F No 105 Wu Kung 3rd Rd Wu Ku Hsiang Taipei Hsine Taiwan Tel 886 2 2299 2499 Korea Mitsubishi Electric Automation Korea Co Ltd 1480 6 Gayang dong Gangseo ku Seoul 157 200 Korea Tel 82 2 3660 9552 Singapore Mitsubishi Electric Asia Pte Ltd 307 Alexandra Road 05 01 02 Mitsubishi Electric Building Singapore 159943 Tel 65 6470 2460 Thailand Mitsubishi Electric Automation Thailand Co Ltd Bang Chan Industrial Estate No 111 Moo 4 Serithai Rd T Kannayao A Kannayao Bangkok 10230 Thailand Tel 66 2 517 1326 Indonesia P T Autoteknindo Sumber Makmur Muara Karang Selatan Block A Utara No 1 Kav No 11 Kawasan Industri Pergudangan Jakarta Utara 14440 P O Box 5045 Jakarta 11050 Indonesia Tel 62 21 6630833 India Messung Systems Pvt Ltd Electronic Sadan NO III Unit No15 M 1 D C Bhosari Pune 411026 India Tel 91 20 2712 3130 Australia Mitsubishi Electric Australia Pty Ltd 348 Victoria Road Rydalmere N S W 2116 Australia Tel 61 2 9684 7777
9. clamped Not doing so can cause the unit or cable to be damaged due to the dangling motion or accidental pulling of the cables or can cause a malfunction due toa cable connection fault When unplugging the cable connected to the unit do not hold and pull from the cable portion Doing so can cause the unit or cable to be damaged or can cause a malfunction due to a cable connection fault Do not drop the module or subject it to strong shock A module damage may result Do not drop or give an impact to the battery mounted to the unit Doing so may damage the battery causing the battery fluid to leak inside the battery If the battery is dropped or given an impact dispose of it without using Before touching the unit always touch grounded metals etc to discharge static electricity from human body etc Not doing so can cause the unit to fail or malfunction Replace battery with GT11 50BAT by Mitsubishi electric Co only Use of another battery may present a risk of fire or explosion Dispose of used battery promptly Keep away from children Do not disassemble and do not dispose of in fire TOUCH PANEL PRECAUTIONS CAUTION For the analog resistive film type touch panels normally the adjustment is not required However the difference between a touched position and the object position may occur as the period of use elapses When any difference between a touched position and the object position occurs execute the touc
10. conductivity may occur due to rain snow etc An outdoor environment 5 2 4 Grounding The following are applicable ground terminals Use them in the grounded state Be sure to ground the GOT for ensuring the safety and complying with the EMC Directive Protective grounding Ensures the safety of the GOT and improves the noise resistance Functional grounding Improves the noise resistance 5 2 5 External wiring 1 External devices When a device with a hazardous voltage circuit is externally connected to the GOT select a model which complies with the Low Voltage Directive s requirements for isolation between the primary and secondary circuits 2 Insulation requirements Dielectric withstand voltages are shown in the following table Reinforced Insulation Withstand Voltage Installation Category II source IEC664 Rated voltage of hazardous Surge withstand voltage 1 2 504 s voltage area 150 VAC or below 2500V 300 VAC or below 4000V 5 3 EMC Directive Compliant System Configuration 5 3 1 GOT Use any of the GOTs with which CE mark logo is printed on the rating plate All GT12 models support the EMC Directive 5 3 2 Cables Modify the cables including user produced cable to ensure compliance with the EMC Directive For details refer to Section 5 4 2 In addition refer to the GOT1000 Series Connection Manual regarding cables to be used 5 4 EMC Directive Compliant System Configuration
11. of the GT12 is the same as that for the GT1155 For details of the installation refer to the following La GT11 User s Manual 7 Wiring comparison Use the same wiring methods of GT16 to configure the GT12 wirings For details of the wiring refer to the following cs GT16 User s Manual Hardware 8 Utility function comparison The operation method of the utility function of the GT12 is the same as that for the GT16 For details on the operation method of the utility function refer to the following CS GT16 User s Manual Basic Utility 9 Message displaying language selectable by utility For the GT12 the message displaying language selectable by the utility is the same as that for the GT11 For details of the relationship between the message displaying language selectable by the utility and the standard font refer to the following KE GT Designer3 Version1 Screen Design Manual Fundamentals Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi machine damage or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties A For safe use This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in
12. on GT Simulator3 If no differences exist in the simulation function for GOT1000 series GT12 simulator and GOT1000 series GT11 simulator on GT Simulator3 the specifications are the same as that for the hardware For details of the hardware specifications refer to the following KE 1 Hardware comparison 3 Function comparison For details of the functions and the utility to operate the GT12 refer to the following C GT Simulator3 Version1 Operating Manual for GT Works3 3 2 Functions that cannot be simulated GOT1000 series GT12 simulator Supported x Not supported GOT1000 series GT11 simulator Relevant manual ome Action GOT type GT12 V GT11 Q setup Resolution 640 x 480 dots 320 x 240 dots Color display 256 colors 256 colors Memory 9MB 3MB Advanced alarm observation o x GT Simulator3 Version1 Operating Historical trend graph oO x Manual for GT Works3 Logging function 0 x Hard copy function o x GT Designer3 GT Designer3 3 Software package support English version Version 1 14Q or later English version Version 1 01B or later 41 For details of the specifications refer to 1 Hardware comparison 2 For details of the functions refer to 3 Function comparison 3 GT Simulator is installed or uninstalled automatically when GT Designer3 is installed or uninstalled 6 Installation comparison The installation method
13. the space so that the leak of electric wave can be suppressed Our test has been carried out on a panel having the damping characteristics of 37dB max and 30dB mean measured by 3m method with 30 to 300MHz 2 Connection of power and ground wires Ground and power supply wires for the GOT must be connected as described below a Provide a grounding point near the GOT Short circuit the LG and FG terminals of the GOT LG line ground FG frame ground and ground them with the thickest and shortest wire possible The wire length must be 30cm 11 81in or shorter The LG and FG terminals function is to pass the noise generated in the PC system to the ground so an impedance that is as low as possible must be ensured As the wires are used to relieve the noise the wire itself carries a large noise content and thus short wiring means that the wire is prevented from acting as an antenna Note A long conductor will become a more efficient antenna at high frequency b The earth wire led from the earthing point must be twisted with the power supply wires By twisting with the earthing wire noise flowing from the power supply wires can be relieved to the earthing However if a filter is installed on the power supply wires the wires and the earthing wire may not need to be twisted 5 1 3 Noise filter power supply line filter The noise filter power supply line filter is a device effective to reduce conducted noise Except some m
14. to the system configuration When multiple GOTs are connected to the Ethernet network Do not set the IP address 192 168 0 18 for the GOTs and the controllers in the network When a single GOT is connected to the Ethernet network Do not set the IP address 192 168 0 18 for the controllers except the GOT in the network Doing so can cause the IP address duplication The duplication can negatively affect the communication of the device with the IP address 192 168 0 18 The operation at the IP address duplication depends on the devices and the system DESIGN PRECAUTIONS CAUTION Turn on the controllers and the network devices to be ready for communication before they communicate with the GOT Failure to do so can cause a communication error on the GOT WIRING PRECAUTIONS lt gt DANGER Be sure to shut off all phases of the external power supply used by the system before wiring Failure to do so may result in an electric shock product damage or malfunctions CAUTION Always ground the FG terminal LG terminal and protective ground terminal of the GOT power to the protective ground conductors dedicated to the GOT Not doing so may cause an electric shock or malfunction Terminal screws which are not to be used must be tightened always at torque 0 5 to 0 8 Nem Otherwise there will be a danger of short circuit against the solderless terminals Use applicable solderless terminals and tighten them with the s
15. 5 VNBA GT1265 VNBD GT1155 QLBD Historical trend graph O Points 300 points Number of pens 8 lines Number of objects on a screen Logging function O Cycle logging trigger 500ms minimum value Number of Screen Design o Manual Functions settings 4 Recipe function oO Recipe count 8192 points is total for all recipe settings 8192 points per 1 recipe setting Recipe file n D drive A drive storage location D drive A drive Bar code function O O RFID function O O Hard copy function O Hard copy file storage location Maximum number of files FA transparent function O GOT maintenance k GOT start time O function GT16 User s Manual Multi channel function O Maximum 2 ch FTP server function O Gateway Functions Manual System monitoring function GOT1000 Series User s Manual Extended Functions Option Functions A list editor function GOT1000 Series FX list editor function User s Manual Extended Functions Option Functions Back up restore function GOT1000 Series GOT data package acquisition User s Manual Extended Functions Option Functions Software package support GT Designer3 1 An option function board is required for the GT11 No option function board is required for the GT12 English version Version 1 01B or later GT Designer3 Japanese version
16. Item GT1275 GT1275 GT1265 GT1265 VNBA VNBD VNBA VNBD GT1155 QSBD GT1155 QLBD STN color liquid STN monochrome Type TFT color liquid crystal display ervstalidis i liquid crystal display y Play white black Screen size 10 4 8 4 5 7 Resolution 640 x 480 dots 320 x 240 dots 211 8 31 W x 171 6 73 W x Display size 158 6 22 H 128 5 04 H 115 4 53 W x 86 3 39 H mm inch mm inch mm inch 16 dot standard font 40 characters 30 16 dot standard font 20 characters 15 Character display lines 2byte character lines 2byte character count 12 dot standard font 53 characters 40 12 dot standard font 26 characters 20 lines 2byte character lines 2byte character Display Monochrome section Color display 256 colors 256 colors white black 16 Scales Left Right 50 Left Right 45 Display angle Left Right 45 degrees degrees degrees Play ang Top Bottom 20 degrees Top 50 degrees Top 20 degrees Bottom 60 degrees Bottom 40 degrees Contrast 16 level adjustment adjustment 2 380 cd m 220 cd m Intensity of LCD _ 200 edim Adjustable in 8 Adjustable in 8 only Adjustable in 4 levels levels levels Life Approx 52 000 h Operating ambient Approx 50 000 h Operating ambient temperature 25 c temperature 25 c Backlight Life Approx 50 000 h or longer Time when display luminance reaches 50 at the operating ambient temperature of 25 c Approx 40 000 h or longer Time when display lumi
17. MITSUBISHI GT12 User s Manual 1 2 GT1275 VNBA GT1275 VNBD GT1265 VNBA GT1265 VNBD Thank you for purchasing the GOT1000 Series Prior to use please read both this manual and the detailed manual thoroughly to fully understand the product MODEL GT12 U SHO E Model code SH NA 080977ENG C 1105 MEE 1D7ME1 GRAPHIC OPERATION TERMINAL GOTDOOO SAFETY PRECAUTIONS Always read these precautions before using this equipment Before using this product please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly The precautions given in this manual are concerned with this prod uct In this manual the safety precautions are ranked as DANGER and CAUTION Indicates that incorrect handling may cause lt amp DANGER hazardous conditions resulting in death or severe injury Indicates that incorrect handling may cause A CAUTION hazardous conditions resulting in medium or slight personal injury or physical damage Nee ese Se S Note that the CAUTION level may lead to a serious accident according to the circumstances Always follow the instructions of both levels because they are impor tant to personal safety Please save this manual to make it accessible when required and always forward it to the end user MOUNTING PRECAUTIONS lt gt DANGER B
18. NBD GT1155 QLBD Shape Rounded o o rectangle GB 65536 points 65536 points GOT internal device GD 65536 points 65536 points Screen Design Vertical format x Manual ie Fundamentals Screen changing Memory card storage for screen transition history ASCIl input display Text alignment Maximum Historical data list number of display objects per screen Date display time View fonnat Date 20 types Date 20 types display Time 6 types Time 6 types Alarm device User alarm n Maximum 8192 Maximum 8192 points Alarm device 3072 3072 points Alaim histo Alarm history D drive 2048 records D drive 2048 records y recorded A drive 3072 records A drive 3072 records File storage D drive A drive D drive A drive location Alarm display function Popup display Screen Design Scrolling displa TSRS Manual Functions Advanced alarm obs ervation O x Advanced user alarm function D drive A drive Number of alarms 8 Advanced system alarm D drive A drive function Line graph Scale points 101 Trend graph Scale points 101 Bar graph Scale points 101 Statistics bar graph Scale points 101 Statistics pie graph Scale points 101 Scatter graph Scale points 101 Circle graph Scale points 101 Continue to next page GT1155 QSBD Relevant manual GT12 GT11 item GT1275 VNBA GT1275 VNBD GT126
19. Wire and connect GOT1000 series equipments as instructed below For the GOT with the 24VDC power supply attach a ferrite core RFC H13 manufactured by KITAGAWA INDUSTRIES CO LTD within the range shown below If the GOT1000 series equipments are configured in a way different from the following instructions the system may not comply with EMC directives 5 4 1 Power and ground wires wiring method 1 Power and ground wires wiring method Connect the power wire and connection cable as shown in the illustration Lead the power wire and ground wire as shown in Section 5 1 2 2 Be sure to ground the LG cable FG cable and protective ground cable 100 240VAC GOT power section INPUT DL x ey Noa hA A oe LG FG 24VDC GOT power section L Ferrite core RFC H13 90mm or less ar M 5 4 2 Processing connection cables Process the cable used with the GOT with the following method When processing the cable ferrite core and cable clamp are required The cable clamp used by Mitsubishi Electric for the EMC specification compatibility test is shown below TDK corporation brand ZCAT3035 1330 Ferrite Core Mitsubishi Electric Model AD75CK cable clamp Japan Zipper Tubing Co Ltd Zipper tube SHNJ type 1 CPU direct connection and computer link connection Strip the outer insulation layer of the prepared cable by the length shown below to expose the braided shield for grounding
20. a device or system used in purposes related to human life Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system Country Region Sales office Tel U S A Mitsubishi Electric Automation Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 U S A Tel 1 847 478 2100 Brazil MELCO TEC Rep Com e Assessoria Tecnica Ltda Rua Correia Dias 184 Edificio Paraiso Trade Center 8 andar Paraiso Sao Paulo SP Brazil Tel 55 11 5908 8331 Germany Mitsubishi Electric Europe B V German Branch Gothaer Strasse 8 D 40880 Ratingen GERMANY Tel 49 2102 486 0 U K Mitsubishi Electric Europe B V UK Branch Travellers Lane Hatfield Hertfordshire AL10 8XB U K Tel 44 1707 276100 Italy Mitsubishi Electric Europe B V Italian Branch Centro Dir Colleoni Pal Perseo Ingr 2 Via Paracelso 12 I 20041 Agrate Brianza Milano Italy Tel 39 039 60531 Spain Mitsubishi Electric Europe B V Spanish Branch Carretera de Rubi 76 80 E 08190 Sant Cugat del Valles Barcelona Spain Tel 34 93 565 3131 France Mitsubishi Electric Europe B V French Branch 25 Boulevard des Bouvets F 92741 Nanterre Cedex France
21. ate and store the GOT in environments without direct sunlight high temperature dust humidity and vibrations Some failures of the GOT communication unit or cable may keep the outputs on or off An external monitoring circuit should be provided to check for output signals which may lead to a serious accident Not doing so can cause an accident due to false output or malfunction If a communication fault including cable disconnection occurs during monitoring on the GOT communication between the GOT and PLC CPU is suspended and the GOT becomes inoperative A system where the GOT is used should be configured to perform any significant operation to the system by using the switches of a device other than the GOT on the assumption that a GOT communication fault will occur Not doing so can cause an accident due to false output or malfunction Do not use the GOT as the warning device that may cause a serious accident An independent and redundant hardware or mechanical interlock is required to configure the device that displays and outputs serious warning Failure to observe this instruction may result in an accident due to incorrect output or malfunction Incorrect operation of the touch switch s may lead to a serious accident if the GOT backlight is gone out When the GOT backlight goes out the POWER LED flickers green orange and the display section turns black and causes the monitor screen to appear blank while the input of the touch switch s
22. dard Compliant Under 5 to 9Hz 35mm 10 times fale te i ise wi i G12 General Description ee There is a storage limit of 6M bytes for project data Vibration resistance 3502 and intermittent 2 araz Noise immunity witha nolge eimultor under 28 to OOH olse Weguency Included with GOT 1D7MB4 i vibration 9 to 150Hz 9 8m s Sraa _ _ n The RS 232 interface is included as standard re S directions Dielectric withstand voltage 500VDC for 1 minute across power terminals and earth F 2 i is i 1131 2 Und n 1 Itis stored as a PDF on the GT Works3 CD ROM The RS 422 485 interface is included as standard a as 5 to 9Hz 4 75mm E insulation re istarico i 10M or mare across power terminals and earth by a 500V The CF card interface is included as standard j 9 to 150Hz 4 9m s The Ethernet interface is included as standard ona i Applicable wire size 0 75 to 21mm 2011 MITSUBISHI ELECTRIC CORPORATION lt The USB interf ibped dad bi h Shock resistance ToC one arenes and IEC 61131 2 147 m s 3 times each Applicable solderless Solderless terminal for M3 screw RAV1 25 3 V2 S3 3 V2 Before using the GOT connect the GOT connector with the battery connector for e interface equipped as stan ar ena es the system Operating No areasy fumes corrosive gas flammable gas excessive terminal NSA FV2 N3A the battery purchased by the customer i startup to be performed more efficiently by using the FA atmosphere conductive dust and direct su
23. e sure to shut off all phases of the external power supply used by the system before mounting or removing the GOT main unit to from the panel Not doing so can cause the unit to fail or malfunction When connecting the battery wear an earth band to avoid damage caused by static electricity MOUNTING PRECAUTIONS CAUTION Use the GOT in the environment that satisfies the general specifications described in this manual Not doing so can cause an electric shock fire malfunction or product damage or deterioration When mounting the GOT to the control panel tighten the mounting screws in the specified torque range Undertightening can cause the GOT to drop short circuit or malfunction Overtightening can cause a drop short circuit or malfunction due to the damage of the screws or the GOT When inserting a CF card into the GOT push it into the insertion slot until the CF card eject button pops out If not properly inserted a bad connection may cause a malfunction When inserting removing a CF card into from the GOT turn the CF card access switch off in advance Failure to do so may corrupt data within the CF card When removing a CF card from the GOT make sure to support the CF card by hand as it may pop out Failure to do so may cause the CF card to drop from the GOT and break Remove the protective film of the GOT When the user continues using the GOT with the protective film the film may not be removed Oper
24. ed 4 2 2For GOTs Sonera from the 24VDC power o we Manual number This manual describes different functions between the GT1275 Display screen L m utiy and ma o y 7 Manual name Model code VNBA GT1275 VNBD GT1265 VNBA GT1265 VNBD hereinafter Touch key ee A Operation at momentary failure STEA EER SH OS0SZENS referred to as GT12 and the GT1156 GSBD GT1155 QLBD Power ermar Pore not wa US oa FO ETTA geist peice fade na hereinafter referred to as GT11 RS 232 interf For communicating with a controller or connecting a Make sure to power on the unit more than 5 seconds after power off gt Sold separately 1D7MD3 For details of the installation method wiring method and utility ees personal computer Connector type D sub 9 pin male 5 i GT16 User s Manual age o parai ROND function refer to description of the GT16 and the GT11 in each RS 422 485 interface Communicating with controller Connector type D sub 4 2 1 For GOTs powered from the 100 to 240VAC GT11 User s Manual JY997D17501A manual Ethernet interface For communicating with a controller or using the FTP server power supply Sold separately 09R815 The GT12 model only has the standard functions available function Connactor type RJ 45 modular jack Speciications GT Designer3 Version Screen Design STOBUSEEENG The following shows defferences between the GT11 and the GT12 USB interface Device B connecting a personal computer Connector type MINI TISINE C ZENNA Manual Fundamentals
25. en using the product in South Korea Failure to observe this instruction may cause a malfunction The followi h th rt for GT1275 and GT1265 When an air purge is made inside the control panel by adding pressure there m i m e tollowing shows the part names tor an fs ing it diffi When transporting lithium batteries make sure to treat them based on the OIE SSS AS UWHA BOA CE ASAE 0 AS g P or pe aaar pee ieee ae sheet ae the screen making it difficutt es ren SS Ske Sess Sia Se t 14 GOT Rear F 12 13 15 to use the touch panel or the sheet may come off _ i transport regulations FASHA BHH ISA USAMA ABIE AS SAS z SUQ Example a 1 ear Face 2 1 15 2 This indicates the section of the power supply to which the equipment is Refer to the User s Manual of the GOT to be used for details of the regurated The product is for business use Class A and meets the electromagnetic GT1275 models compatibility requirements The seller and the user must note the above point and use the product in a place 2 3 gt except for home AGN Tek oe mi assumed to be connected between the public electrical power distribution tO 1 network and the machinery within the premises iii ci Ap 9 Category II applies to equipment for which electrical power is supplied from Mt M y mo pew fixed facilities i Gi Make sure to transport the GOT main unit and or relevant unit s in the manner they will not be exposed to the impact exceeding the impact
26. following j j aa Panel thickness 2 to 4mm 0 08 to 0 16inch c Installation When the When the Environment CF cardis CF card is not used used In the presence of radiated noise or 50 1 97 80 3 15 50 1 97 100 3 94 heat generating ormore or more or more or more equipment nearby 100 3 94 In the absence of or more radiated noise or 20 0 79 20 0 79 20 0 79 20 0 79 heat generating or more or more or more or more equipment nearby Unit mm inch MITSUBISHI GT12 User s Manual 2 2 GT1275 VNBA GT1275 VNBD GT1265 VNBA GT1265 VNBD Thank you for purchasing the GOT1000 Series Prior to use please read both this manual and the detailed manual thoroughly to fully understand the product MODEL GT12 U SHO E Model code 1D7ME1 SH NA 080977ENG C 1105 MEE GRAPHIC OPERATION TERMINAL GOTio900 7 SPECIFICATION FUNCTION COMPARISON FOR GT12 AND GT11 The table overview shows the different specifications and functions available on the GT12 and the GT11 For details of each function refer to the relevant manual 1 Hardware comparison The following shows the differences in hardware on the GT12 and the GT11 Supported x Not supported Not necessary Relevant manual GT11 User s Manual Hardware GT12 GT11
27. h panel calibration When any difference between a touched position and the object position occurs other object may be activated This may cause an unexpected operation due to incorrect output or malfunction BACKLIGHT REPLACEMENT PRECAUTIONS lt gt DANGER Before replacing the backlight be sure to switch off the GOT power supply externally for all phases and remove the GOT unit from the control panel Not switching the power off in all phases may cause an electric shock Not removing the unit from the control panel can cause injury due to a drop CAUTION When replacing the backlight use the gloves Otherwise it may cause you to be injured Start changing the backlight more than 5 minutes after switching the GOT power off Not doing so can cause a burn due to the heat of the backlight DISPOSAL PRECAUTIONS CAUTION When disposing of this product treat it as industrial waste When disposing of batteries separate them from other wastes according to the local regulations Refer to the User s Manual of the GOT to be used for details of the battery directive in the EU member states TRANSPORTATION PRECAUTIONS Compliance with the Radio Waves Act South Korea a 1 Do not use or store the GOT under pressure higher than the atmospheric This product complies with the Radio Waves Act South Korea 3 PART NAMES AN D SETTI NGS pressure of altitude Om Oft CAUTION Note the following wh
28. igned to be stored within another device be sure to use it only when installed in a control panel 1 Shock Protection In order to prevent those who are unfamiliar with power facility e g an operator from getting a shock make sure to take the following measures on the control panel a Store the GOT within the control panel locked and allow only those who are familiar with power facility to unlock the panel b Build the structure in order that the power supply will be shut off when the control panel is opened Dustproof and waterproof features The control panel also provides protection from dust water and other substances Insufficient ingression protection may lower the insulation withstand voltage resulting in insulation destruction The insulation in the GOT is designed to cope with the pollution level 2 so use in an environment with pollustion level 2 or better 2 Pollution level 1 An environment where the air is dry and conductive dust does not exist Pollution level 2 An environment where conductive dust does not usually exist but occasional temporary conductivity occurs due to the accumulated dust Generally this is the level for inside the control panel equivalent a control room or on the floor of a typical factory Pollution level 3 An environment where conductive dust exits and conductivity may be generated due to the accumulated dust An environment for a typical factory floor Pollution level 4 Continuous
29. is of the requirement items and standards of the restrictions gathered by Mitsubishi they do not completely guaranteed that all mechanical unit manufactured according to the data do not always match the above directives The manufacturer itself which manufactures the mechanical unit must finally judge the method and others to match the EMC directives 5 1 1 EMC directive The standards of the EMC Directive are shown below Applied standard Test standard Test details Standard value 30M 230MHz QP Electromagnetic 30dBy V m 30m in measurement N55011 emissions from the range 3 Radiated noise product are 230M 1000MHz QP measured 37dBuV m 30m in measurement range 3 Electromagnetic 150k 500kHz QP 79dB emissions from the Mean 66dB product to the power 500k 30MHz QP 73dB line is measured Mean 60dB EN55011 Conducted noise Immunity test in EN61000 4 2 which static Electrostatic electricity is applied immunity to the cabinet of the equipment 4kV Contact discharge 8kV Aerial discharge EN61000 4 3 Immunity test in 80 1000MHz 10V m Radiated electro which field is 1 4 2GHz 3V m magnetic field AM irradiated to the 2 0 2 7GHz 1V m modulation product 80 AM modulation 1kHz Immunity test in Power line 2kV which burst noise is Digital I O 24V or higher 1kV applied to the power Digital I O 24V or less gt 250V line and signal lines Analog I O signal line
30. ith the EMC Directives if it is actually compliant with the EMC Directives a For RS 422 485 cable Each signal wire excluding SG and FG should be made into a two power wires and connected then twisted eee RDA s08 ae Xl R RDA e SDA a E Ye X b Make the SG wire more than two wires and connect Strip the outer insulation layer of the prepared cable by the length shown below to expose the braided shield for grounding For grounding with cable clamps Refer to Section 5 4 3 GOT side PLC side 3 gt 230 or less 9 06 40 1 57 Unit mm inch b For RS 232 cable Use a twisted pair style for each signal wire except SG FG with SG RD x 80 SD gt lt RD DTR lt I DSR DSR lt DTR SG SG Strip the outer insulation layer of the prepared cable by the length shown below to expose the braided shield for grounding For grounding with cable clamps Refer to Section 5 4 3 GOT side PLC side Ol i yel T M0 230 or less 9 06 4001 57 Unit mm inch 5 4 3 Grounding the cable Ground the cable and grounding wire to the control panel where the GOT and base unit are installed 1 Ground the braided shield portion of the cable to the control panel with the cable clamp AD75CK Braided shield 2 Do not arrange the cable clamp adjacent to other cables which do n
31. n installation and wiring of the GOT to conform to the Low Voltage Directive requires are described We have put the maximum effort to develop this material based on the requirements and standards of the Directive that we have collected However compatibility of the devices which are fabricated according to the contents of this manual to the above Directive is not guaranteed Each manufacturer who fabricates such device should make the final judgement about the application method of the Low Voltage Directive and the product compatibility 5 2 1 Standard subject to GOT Standard applied to GOT EN61131 2 Programmable controllers Equipment requirements and tests EN60950 1 Safety of Information Technology Equipment 5 2 2 Power supply The insulation specification of the GOT was designed assuming installation category II Be sure to use the installation category II power supply to the GOT The installation category indicates the durability level against surge voltage generated by lightning strike Category has the lowest durability category IV has the highest durability A coy O lt gt a ae gt Category IV Category Ill Category II Category Installation category Category II indicates a power supply whose voltage has been reduced by two or more levels of isolating transformers from the public power distribution 5 2 3 Control panel Because the GOT is open type equipment device des
32. nance reaches 50 at the operating ambient temperature of 25 c Approx 75 000 h or longer Approx 54 000 h or longer Type Analog resistive film Matrix resistive film Number of touch 300 keys screen Matrix structure of 15 keys lines X 20 columns Touch GT16 User s Manual OUG Key size Minimum 2 x 2 dots per key Maximum 16 x 16 dots per key Hardware panel GT11 User s M Number of objects ser s Manual that can be Simultaneous presses not allowed Maximum of 2 points simultaneously Only 1 point can be touched P touched Memory C drive Built in flash memory 9MB Built in flash memory 3MB GT11 User s Manual USB device O Rear side x Front side Built in Option function Option functions supported as standard Option function board is necessary for board option function use interface Ethernet o x GT16 User s Manual Hardware Continue to next page GT12 ltem GT1275 VNBA 303 11 93 W x 214 8 43 H x 53 2 09 D mm inch External dimensions GT1275 GT1265 GT1265 VNBD VNBA VNBD 241 9 49 W x 190 7 48 H x 58 2 29 D mm inch Relevant manual GT1155 QSBD GT1155 QLBD 164 6 46 W X135 5 32 H x 56 2 21 D mm inch 289 11 38 W x 200 7 87 H mm inch Panel cutting dimensions 227 8 94 W x 176 6 93 H mm inch 153 6 03 W x 121 4 77 H mm inch 744 User s Manual Weight mo
33. nlight Same as storage atmosphere Applicable tightening torque Refer to the GT11 User s Manual for the connection method transparent function FA equipment setup tool It also reduces Operating alttude t 2000 m 6562 fij max Terminal block terminal 0 5 to 0 8 N m For details on the GT12 wiring maintenance and inspection methods for the indirect work replacing cables cable rewiring to further r r inside contol panel S screw checking the version and the compatible standards and others refer to the GT11 User s Manual improve work efficiency hci 1 In this product the surge absorber is connected between the power supply and The blown backlight bulb can be confirmed even during screen r or less the ground to avoid a malfunction due to noise caused by the application of i indi inki ji i Pollution degree 2 or less lightning surge r noce by the POWER LED blinking with backlight Cooling es Self cooling The values of the dielectric withstand voltage and insulation resistance are snuto etection Groundin D type grounding with a resistance of 1009 or less ground to panel recorded when the surge absorber is not connected g when grounding is not possible 4 3 External Dimensions GT1275 VNBA GT1275 VNBD GT1265 VNBA GT1265 VNBD 303 11 93 241 9 49 252 9 92 175 5 6 91 10 0 39 0 39 10 190 7 48 199 7 83 214 8 43 175 6 89
34. odels installation of a noise filter onto the power supply lines is not necessary However conducted noise can be reduced if it is installed The noise filter is generally effective for reducing conducted noise in the band of 10MHz or less Usage of the following filters is recommended Model name FN343 3 01 FN660 6 06 2ZHC2203 11 Manufacturer SCHAFFNER SCHAFFNER Rated current 3A 6A Rated voltage 250V The precautions required when installing a noise filter are described below 1 Do not install the input and output cables of the noise filter together to prevent the output side noise will be inducted into the input side cable where noise has been eliminated by the noise filer Input side power supply side power supply side Input side Induction Filter JE Output side E f Output side device side device side Installing the input and output cables Separate the input cable from the output together will cause noise induction cable 2 Connect the noise filter s ground terminal to the control panel with the shortest cable as possible approx 10cm 3 94 in or less 5 2 Requirements for Compliance with the Low Voltage Directive The Low Voltage Directive requires each device which operates with power supply ranging from 50VAC to 1000V and 75VDC to 1500V to satisfy necessary safety items In the Sections from 5 2 1 to 5 2 5 cautions o
35. ot clamp Noise from the control panel may access the GOT from the cable clamp and cause adverse effects 6 INSTALLATION 6 1 Control Panel Inside Dimensions for Mounting GOT Install the GOT on the control panel out of the way for the equipment inside the control panel Do not install the GOT and the unit in prohibited areas for the installation When mounting the GOT to the control panel place the mounting fixtures included with GOT on the mounting fixture attaching part of the GOT and fix them by tightening in the torque range of 0 36 to 0 48Nem Applicable cable Some cables may need to be longer than the specified dimensions when connecting to the GOT Therefore consider the connector dimensions and bending radius of the cable as well for installation 6 2 Panel Cutting Dimensions A Panel thickness 2 to 4mm I orless GOT A B 289 200 GT1275 11 38 7 87 a 2 0 08 2 0 08 0 0 0 0 227 176 GT1265 8 94 6 93 2 0 08 2 0 08 0 0 0 0 Unit mm inch 6 3 Mounting Position When mounting the GOT the following clearances must be maintained from other structures and devices Some cables may need to be longer than the specified dimensions when connecting to the GOT Therefore consider the connector dimensions and bending radius of the cable as well for installation For the lead in allowance for cables at the bottom of the GOT refer to the
36. pecified torque If any solderless spade terminal is used it may be disconnected when the terminal screw comes loose resulting in failure Correctly wire the GOT power supply section after confirming the rated voltage and terminal arrangement of the product Not doing so can cause a fire or failure Tighten the terminal screws of the GOT power supply section in the specified torque range Undertightening can cause a short circuit or malfunction Overtightening can cause a short circuit or malfunction due to the damage of the screws or the GOT Exercise care to avoid foreign matter such as chips and wire offcuts entering the GOT Not doing so can cause a fire failure or malfunction The module has an ingress prevention label on its top to prevent foreign matter such as wire offcuts from entering the module during wiring Do not peel this label during wiring Before starting system operation be sure to peel this label because of heat dissipation Plug the communication cable into the connector of the connected unit and tighten the mounting and terminal screws in the specified torque range Undertightening can cause a short circuit or malfunction Overtightening can cause a short circuit or malfunction due to the damage of the screws or unit TEST OPERATION PRECAUTIONS lt gt DANGER Before performing the test operations of the user creation monitor screen such as turning ON or OFF bit device changing the word device cu
37. resistance described in the general specifications of the User s Manual of the 1 __ pu The surge voltage withstand level for up to the rated voltage of 300 V is 2500 V GOT to be used as they are precision devices Packing List ji m z th 3 TS ee eden o nieh comune material is generated in the Failure to do SPEY Cause the unit to fail A The GOT product package includes the following i In pollution degree 2 oniy Aon condluctive Polution occurs but temporary Check if the unit operates correctly after transportation Spe conductivity may be produced due to condensation Model Descripti 14 8 ption Point GT1275 VNBA GOT ai GT1275 VNBD Installation fitting Hi les ipo Refer to GT12 Supplementary Description for details on the performance specifications of Manuals GT1265 VNBA each GOT _ GT GT12 General Description 7 6 5 4 4 2 Power Supply Specifications The following shows manuals relevant to this product Description i follewitia indicat Pp y SP i ificati for GT12 Lit in green Power is correctly supplied e following Indicates the power supply specifications tor 4 1 OVE RVI EW Lit in orange Screen saving POWER LED i i 54 24 For GOTs powered from the 100 to 240VAC power suppl Relevant Manual Nol range sateen Poue poteuew
38. rrent value changing the settings or current values of the timer or counter and changing the buffer memory current value read through the manual carefully and make yourself familiar with the operation method During test operation never change the data of the devices which are used to perform significant operation for the system False output or malfunction can cause an accident STARTUP MAINTENANCE PRECAUTIONS lt gt DANGER When power is on do not touch the terminals Doing so can cause an electric shock or malfunction Correctly connect the battery connector Do not charge disassemble heat short circuit solder or throw the battery into the fire Doing so will cause the battery to produce heat explode or ignite resulting in injury and fire Before starting cleaning or terminal screw retightening always switch off the power externally in all phases Not switching the power off in all phases can cause a unit failure or malfunction Undertightening can cause a short circuit or malfunction Overtightening can cause a short circuit or malfunction due to the damage of the screws or unit STARTUP MAINTENANCE PRECAUTIONS CAUTION Do not disassemble or modify the unit Doing so can cause a failure malfunction injury or fire Do not touch the conductive and electronic parts of the unit directly Doing so can cause a unit malfunction or failure The cables connected to the unit must be run in ducts or
39. ry is 3MB whereas it Inside cover 422 485 communication port i _ ous SH 080869ENG i i Hole k T Noise i it 1 500Vp p noise voltage 1 us noise width when measuring Non Mitsubishi Products 1 for GT Works3 1D7MC3 is possible to use 9MB on the GT12 for user memory brett Hole for inserting the unit installation fitting iii with a noise simulator under 25 to 60Hz noise frequency installation fitting Installation switch Used for OS installations at the GOT startup Sold separately 1 Dielectric withstand voltage 1500VAC for 1 minute across power terminals and earth GOT1000 Series Connection Manual SH 080870ENG Non Mitsubishi Products 2 for GT Works3 Sold separately 1D7Mc4 2 FEATURES 4 SPECIFICATIONS 10M or more across power terminals and earth by a 500V DC insulation resistance tester Insulation resistance Applicable wire size 0 75 to 2 mm GOT1000 Series Connection Manual sei i Applicable solderless Solderless terminal for M3 screw RAV1 25 3 V2 S3 3 V2 Microcomputer MODBUS Products SH 080871ENG 4 1 General Specifications terminal N3A FV2 N3A Peripherals for GT Works3 1D7MC5 1 Improved monitoring performance and connectivity to FA devices Sold separately Provides multi language display function based on Unicode2 1 _ True Type font and produces clear beautiful text through high Display Applicable tightening torque Terminal block terminal 0 5 to 0 8 Nem
40. s gt 250V EN61000 4 4 Fast transient burst noise AC power type Power line between line and ground 2kV Power line between lines 1kV Data communication port 1kV DC power type Power line between line and ground 0 5kV Power line between lines 0 5kV Data communication port 1kV Immunity test in EN61000 4 5 which lightening Surge immunity surge is applied to the product Continue to next page Applied standard Standard value Test standard Test details Immunity test in EN61000 4 6 which a noise Conducted RF inducted on the immunity power and signal lines is applied Power line 10V Data communication port 10V Test for checking normal operations under the circum stance exposed to the ferromagnetic field noise of the power supply frequ ency 50 60Hz EN61000 4 8 Power supply frequency magnetic field immunity AC power type EN61000 4 11 0 5 cycle 0 interval 1 to 10s Test for checking normal operations at instantaneous power failure Instantaneous power failure and voltage dips immunity 250 300 cycle 0 10 12 cycle 40 25 30 cycle 70 DC power type 10ms interval 1 to 10s 1 The GOT is an open type device device installed to another device and must be installed in a conductive control panel The above test items are conducted in the condition where the GOT is installed on the conductive control panel and combined
41. unting fixtures are not included 2 3kg 5 1Ib 1 7kg 3 7Ib 0 7kg 1 51b 100 to Power supply 240VAC 2 Option comparison 100 to 240VAC 1 The limit for available storage for project data is 6MB DC24V The following shows the differences in options on the GT12 and the GT11 O Supported x Not supported GT12 GT11 tem GT1275 VNBA GT1265 VNBA GT1155 QSBD Relevant manual GT1275 VNBD GT1265 VNBD GT1155 QLBD Clear GT11 70PSCB GT11 60PSCB GT11 50PSCB Antiglare GT11 50PSGB Protective sheet ae deat GT11 50PSCW GT11 User s Manual Antiglare Frame white GT11 50PSGW GT11 j Battery 50BAT O Pre attached for shipment GT15 70 ATT 98 GT15 70 ATT 87 GT15 60 ATT 97 1 Attachment ve anser s Manual GT15 60 Hardware ATT 96 GT15 60 ATT 87 GT15 60 ATT 77 Stand GT15 70STAND GT05 50STAND GT16 User s Manual Hardware Backlight GT12 70VLTN GT12 60VLTN Replacement unavailable GT11 User s Manual 1 The GOT automatically formats the D drive SRAM when the battery is not attached Attach the battery to keep clock and alarm history data 3 Function comparison The following shows the differences in functions on the GT12 and the GT11 For details of the utility screen refer to the GT16 User s Manual Supported X Not supported Not necessary Relevant manual GT12 GT11 Item GT1275 VNBA GT1275 VNBD GT1155 QSBD GT1265 VNBA GT1265 V
42. with the Mitsubishi PLC 2 QP Quasi Peak Quasi peak value Mean Average value 3 The above test items are conducted in the following conditions 30M 230MHz QP 40dBy V m 10m in measurement range 230M 1000MHz QP 47dBu V m 10m in measurement range 5 1 2 Control panel The GOT is an open type device device installed to another device and must be installed in a conductive control panel It not only assure the safety but also has a large effect to shut down the noise generated from GOT on the control panel 1 Control Panel a The control panel must be conductive b When fixing a top or bottom plate of the control panel with bolts do not coat the plate and bolt surfaces so that they will come into contact And connect the door and box using a thick grounding cable in order to ensure the low impedance under high frequency c When using an inner plate to ensure electric conductivity with the control panel do not coat the fixing bolt area of the inner plate and control panel to ensure conductivity in the largest area as possible d Ground the control panel using a thick grounding cable in order to ensure the low impedance under high frequency e The diameter of cable holes in the control panel must be 10cm 3 94in In order to reduce the chance of radio waves leaking out ensure that the space between the control panel and its door is small as possible Paste the EMI gasket directly on the painted surface to seal