WGWNA-B WEB Gateway Product Specification Dec 2009

image

Contents

1. in the Fig 4 1 Terminal block A and B Terminal block A and B FUSE POWER e e QN VOLTAGE ONLY s SC WGWNA SUPERLINK 6 amp SELECTION SWITCH Pres int NEW SUPERLINK DIN Gorka 5 im DEFAULT ol H LH 5 PREV SUPERLINK IM SELECTION EXAM 5 REQUIRE mae MIT PUR i B Aa MITSUBISHI Lo Terminal block pulse inputs For ethernet Watimeter Gasmeter Terminal block L N Ground RJ45 connector Ethernet AC 100 240V mus connect wattmeters gasmeters that satisfy the specifications Superlink 511 elow Nonvoltage contact pulse Superlink SL2 Pulse width 100ms or more Fig 5 1 SC WGWNA B Wring If the previous SUPERLINK communication system is to be used change selection switch to PREV Previous SUPERLINK side 16 SC WGWNA B Product Specification Ver 1 0 Document No 157209025 Deci O00 1 2009 5 3 ETHERNET CABLE This Gateway supports the Ethernet 10 or 100BASE TX which are most popular among the standards of the Ethernet the case of only one PC is used for control and monitor the PC and the Gateway can be connected directly by a cross Ethernet cable Thecross cableis a kind of Ethernet cable which connects two computers directly the case of using more than one PCs for control and monitor an Ethernet HUB must be used For either cases the category 5 cable grade or higher must b
2. Function Content C On Off command Send the On Off command toa CELL O Mode command Send the operation mode command Auto Cooling Dry N Heating Fan toa CELL T Setpoint command Send the temperature setpoint command toa CELL The R range is from 18 0 to 30 0 degrees Celsius O Fan Speed command Send the fan speed select command Powerful High Medium L Low toa CELL Remocon Lock U nlock Send the remote controller operation Lock or Unlock command command toaCELL Filter Sign Reset command Send thereset command for the filter sign on the remote controller of aCELL System Stop command Send the Off commands to all CELLs and set all CELLs as the Remocon Lock mode simultaneously M Failure status Monitor the failure status LE D on off on the remote controller for a CELL On Off status Monitor the On Off status of a CELL Mode status Monitor the operation mode status of a CELL T Setpoint status Monitor the setpoint status of aCELL O Fan Speed status Monitor the fan speed select status of a CELL R Remocon Lock Unlock status Monitor the setting of the remote controller Lock Unlock mode of a CELL Filter Sign status Monitor the status of the filter sign LED on the remate controller of a CELL Room Temperature Status Monitor the room temperature sensor data of a CELL A CELL is a group of the indoor units connected by remocon or an indoor unit In som
3. 90 91 BB Room 92 Broom 93 I Room 94 el Room 95 fd fe Room 96 DS asso Bran Plato Data E Done Local intranet Fig 623 ALARM at the linked WEB Gateway 21 SC WGWNA B Product Specification Ver 10 Document No 157209025 Dec j O00 1 2009 6 3 INDIVIDUAL MONITOR SCREEN This screen is for indicating the detail information on one of the CELLs by the pop up window in front of the above mentioned Overview Monitor screen items of monitoring information are the place short name the place description the On Off M ode icon the setpoint the room temperature the remocon lock unlock status the filter sign status and the error code of the selected CELL By clicking a short place name for a CELL on the Overview Monitor screen the corresponding Individual Monitor window will pop up in front of the Overview Monitor screen If another Individual Monitor window is opened it will pop up the same place on the screen and consequently the previous Individual Monitor window will disappear Both thelndividual Monitor window and the Overview Monitor screen automatically refresh themselves at the same interval set in the Communication Configuration screen t may take several seconds to refresh an Individual Monitor window of a CELL depending on the network situation Even in the case that a Failure status icon comes on behind the Individual Monitor window the Failure icon does not move to the fro
4. en insane 709 05 A02 A001 ADU WGWNA B 41 Outline Drawing of SC Fi 15 SC WGWNA B Product Specification Ver 10 Document No 157209025 Deci O00 1 2009 5 INSTALLATION 5 1 INSTALLATION CONDITIONS This Gateway SC WGWNA B has a terminal block for the AC power supply on the outside surface of the casing For avoiding electrical shock injury the SC WGWNA B should be installed inside a cabinet with a lock The direction of placement of this Gateway when installation should be such a way that the front panel is vertical and the lettering of the front panel is right direction because of air cooling The recommended service space surrounding this Gateway is as follows Upper clearance Minimum 30 mm Lower clearance Minimum 30 mm Right side clearance Minimum 50 mm more than 200 mm is recommended Left side clearance Minimum 50 mm more than 200 mm is recommended The side clearance is for wiring workspace 5 2 WIRING The Fig 5 1 shows the wiring of this Gateway After wiring to the WEB Gateway the terminal covers which are included in this Gateway s product package should be installed by screws as shown
5. 3 2 Previous SUPERLINK communication system The maximum number of indoor units connected is shown in the Table 2 4 1 depending on connection of the SUPERLINK option controller such as SLIN SLA 1 SL2N SLA 2A The reason why the number of indoor units connectable is reduced in the case of option controller connection is for communication traffic limitation Table 2 4 1 Wthout option controller Wth option controller Nurrber of SUPERLINK networks 2 networks 2 networks Nurrber of indoor units Max 48 units x 2 2Max 96 Max 44 units x 2 Max 88 GHP 8 series or above CELL 0 to CELL 95 CELL to CELL 95 Skipping CELL No is acceptable Skipping CELL No is acceptable Max 32 units x 2 Max 64 Range of CELL nurrber Option controllers should be max 2 of SLIN SLA 1 or only one of SL2N SLA 2A for one SUPERLINK network SC WGWNA B Product Specification Ver 10 Document No 157209025 Deci O00 1 2009 2 5 POWER CONSUMPTION CALCULATION 1 Software Overview This gateway provides a function of the power consumption calculation by using a personal computer with the software SL3N BE Utility which is induded in this product package This gateway collects the data of the total power consumption for the air conditioners and the each Air con CELL s running data The energy consumption calculated by this equipment dose not conform to the OIML International Organization of Legal Metrology 2 Flow of data processing Thi
6. O00 1 2009 3 FUNCTION OVERVIEW 3 1 WEB SERVER FUNCTION OVERVIEW The WEB Server functions mean functions as a WEB server from the WEB browser s point of view The Table 3 1 shows the list of the WEB functions of the SC WGWNA B Gateway Table 3 1 List of the WEB Server Functions List of Screens WEB Function Screen Content Login Authentication of the user by the UserID and Password Overview M onitor Display the overall status of all CELLs of the whole PAC system without scroll of the screen Individual Monitor Display the detail status of each CELL in the pop up window Control Command Input Control command to CELLs by thearray of pull down menus System Stop Stop all the CELLs and set the remote controller reject mode by one dick PAC Configuration Set the full room name and the short name for each CELL These names to appear on the Monitor screen Config File Transfer Upload and Download of the PAC Information CSV file which defines the indoor unit grouping of the CELL s Communication buzzer Se the browser s auto refresh interval of the Overview Monitor screen Config Se the alarm buzzer On Off Link Config Se thelink another WEB Gateway Security Config Set the accessible address of a PC that is IP address filtering Password Change Password can be changed from this screen Calendar Config Set the yearly calendar defining each day as Weekday Holiday etc
7. This yearly calendar is common to all CELLs Master Schedule Config The Master Schedules are default daily operation schedules depending on a day of a week or a spedal day Set each Master Scheduleof a CELL Each CELL has a different default daily schedule Schedule Control Se temporarily alternation to the daily operation schedule of a CELL for maximum 7 days from the current day Thetemporary alternation does not affect the Master Schedule Calendar Schedule Backup Makes a schedule calendar backup file and downloads uploads the file File Transfer Date Time Set Adjust the date and time of the WEB server NTP Config Se the NTP server synchronizing thetime Power Consumption Downloads data files for power consumption calculation utility software Calculation File Download onthePC Power Consumption Defines high low charging period of a day Charging Period set CELL is a group of the indoor units connected by one remocon an indoor unit remocon is a packaged air conditioner s remote controller 12 SC WGWNA B Product Specification Ver 1 0 Document No 157209025 Deci O00 1 2009 3 2 CONTROL amp MONITOR FUNCTION OVERVIEW The control and monitor functions mean categories of jobs from an air conditioning system s point of view TheTable 3 2 shows the control and monitor functions of the SC WGWNA B Gateway Table 3 2 List of Control amp Monitor Functions of the SC WGWNA B
8. Use NTP Service v NTP Server IPAddress 192 168 0 1 Difference in time with UTC 49 0 Local intranet Fig 6 18 NTP CONFIGURATION SCREEN 37 SC WGWNA B Product Specification Ver 10 Document No ISTZ09025 Decl O00 1 2009 6 19 POWER CONSUMPTION DATA DOWNLOAD SCREEN This screen is for downloading the power consumption data files Accounting Files to the browsing PC This screen can be reached from the configuration menu of this gateway in the case of logging in by the Admin user ID These power consumption files are common format as the SL3N BE controller By clicking each Download button the definition file or each data fileis automatically downloaded to the browsing PC a Accounting File Download Microsoft Internet Explorer File Edit Favorites Tools a So BaG FAHeK eO B SEDA Address a http 192 168 0 110 en payfiledownload php v West North South Overview Monitor Control Commnand Schedule Control System Stop Release Configuration Menu SUPERLINK WEB GATEWAY Accounting File Download MITSUBISHI Definition file Will be downloaded as the file name SL3Nconfig bin Download Monthly data file Will be downloaded as the file name SL3NcostYYMM bin Year Month 2008 07 2008 08 2008 09 2008 10 2008 11 2008 12 2009 01 2009 02 2009 03 2009 04 load 2009 05 Download 2009 06 Download Done Local intranet Fig 6 19
9. 00000000 System WEB Gateway No 1 ecce WEB Gateway No4 SC WGWNA B WEB Gateway link SC WGWNA B Max 4 Gateways SUPERLINK No network SUPERLINK No network mt mp Adapter SinjePAC 2 B 09 Sinde PAC Outdoor OT E RR IndoorUnit feososeseoosseoeceoooceoo eessoccesccccecocec IndoorUnit i IndoorUnit R IU 63 SLIN SLN CELL No allocation FromCELL 0 to CELL 95 can be allocated SLIN Skipping CELL No is acceptable OutdoorUnit OutdoorUnit of indoor units for one SUPERLINK 0 Max 64 indoor units can be connected d Nurrber of outdoor units for SUPERLINK ares ares network OutdoorUnit OutdoorUnit Max 12 recorrmended OU OU 11 Fig 2 1 2 System Diagram Option controller connected case of the new SUPERLINK communication systeni SC WGWNA B Product Specification Ver 1 0 Document No 157209025 Deci O00 1 2009 Fig 2 1 3 shows a case that 65 or more indoor units up to 128 units are connected to one SUPERLINK communication system Compared to 64 units each on two SUPERLINK network systems Fig 2 1 2 the network traffic is douded so the communication speed to each indoor unit becomes slow Then it is recommended that using two SUPERLINK network systems To use the WEB Gateway in this system it is required to switch the system program Please refer to the con
10. 10 Document No 157209025 1 2009 Fig 2 1 5 shows a case of the previous SUPERLINK communication system diagram of connection between the building management system host computer the WEB Gateway and the SUPERLINK control networks along with SUPERLINK option controllers such as SLIN SLA 1 or SL2N SLA 2A TheSC ADN SC AD L adapter should be used for connection of MHI s single type packaged air conditioner models Previous Cortrol amp Monitor PC EE System 4 PCs Explorer WEB Gateway No 1 ecco WEB Gateway No 4 SC WGWNA B WEB Gateway link SC W3GWNA B Max 4 Gateways SUPERLINK No network SUPERLINK No network 0 CELL PH IndoorUnit gt 170 IR P IU 1 CEDE YO ss IndoorUnit i AL Adapter SingePAC RI 2110 2 jungand Singe MERE PAC Outdoor ee RR i U3 pu lt gt NR I IndoorUnit 2 13 231 PHR SLIN SLN CELL No allocation FromCELL 0 to CELL 95 be allocated SLIN Skipping CELL No is acceptable OutdoorUnit OutdoorUnit of indoor units for one SUPERLINK 0 Max 32 indoor units be connected in case SLIN or SL2N etc is connected aa ras any Nurrber of outdoor units for SUPERLINK OutdoorUnit OutdoorUnit network OU OU 11 Max 12 recommended Fig 2 1 5 System Diagram
11. 34 B Room 35 S Room 36 4 37 38 39 ry Room 40 A Room 41 A Room 42 A Room 43 44 Room 45 Room 46 Room 47 Room 48 Room 49 E Room 50 BE Room 51 E Room 52 S Room 53 54 S Room 55 amp Room 56 Room 57 Room 58 Room 59 Room 60 A Room 61 A Room 62 A Room 63 A Room 64 Room 65 0 Room 66 Broom 67 o Room 68 BE Room 69 70 BE Room fi BB Room d Room 73 Room 74 E Room 75 5 Room 76 Room 77 Room 78 8 75 Room 80 A Room 81 A Room 82 A Room 83 A Room 84 8 85 86 Room 87 Room 88 8 89 90 BB Room 91 BB Room 92 room 93 PIP Room 94 fa fe Room 95 el Room 96 WD ato Brea Booo Bra Woy F No Data E amp Local intranet Fig 622 ALARM BUZZER STOP BUTTON 20 SC WGWNA B Product Specification Ver 10 Document No ISTZ09025 Decl O00 1 2009 When the linkage with other WEB Gateways is set see dause 6 10 the Link Name Tab is displayed in yellow if an air conditioner failure stop occurs at the other WEB Gateway I n this case also the web browser will sound the alarm buzzer if the Alarm buzzer setting is ON By dicking the Link Name Tab the screen of the WEB Gateway is displayed While the buzzer is sounding the MHI s logo on the upper right corner of the screen will be replaced by the red buzzer stop button By dicking this button all browser PC s buzzer will cease However this operati
12. CONFIGURATION SCREEN 26 SC WGWNA B Product Specification Ver 10 Document No ISTZ09025 Decl O00 1 2009 6 8 AIR CON CELL CONFIGURATION FILE UPLOAD DOWNLOAD SCREEN These screens control upload download of the WGWconfig csv file which is a configuration file for the CELLs for packaged air conditioners thelist of CELL definitions that is the comma separated values of the CELL numbers the SUPERLINK channels and the indoor unit numbers the place names and the short place names The CSV file can be edited and uploaded to change the Air con Cell configuration Caution In this file WGWconfig csv comma is used as record separator character Therefore be sure not to use comma as decimal mark E hir con Cell Configuration File Upload Microsoft Internet Explorer File Edit View Favorites Tools Help o o 8 6P ee Address 4 http 192 168 0 110 en upload php North Overview Monitor Control Commnand Schedule Control System Stop Release Configuration Menu SUPERLINK WEB GATEWAY Air con Cell Configuration File Upload 3 MITSUBISHI INDUSTRIES LTD Air con Cell Configuration File IL Browse Local intranet Fig 6 8 1 AIR CON CELL CONFIGURATION UPLOAD SCREEN Cell Configuration File Download Microsoft Internet Explorer File Edit View Favorites Tools a nmre OS 2 A au Address http 192 168 0 110 en downl
13. Gateway fails to receive the change of state broadcast from an indoor unit the change of the On Off status indication would delay for about 1 minute at the worst case 7 9 OPERATION MODE STATUS The Operation mode status indicates the status of operation mode that is AutoM ode Cooling Mode DryM ode eatingM ode or FanMode of a CELL Each operation mode is same as that indicated on the remocon of the CELL This operation mode status of a CELL indicates not only result of a control command from this Gateway but also result from other controllers For example the operation mode status reflects change of state of a CELL from the remote controller as well as from this Gateway As above mentioned in a rare case that this Gateway fails to receive the change of state broadcast from an indoor unit the change of the operation mode indication would delay for about 1 minute at the worst case 7 10 SETPOINT STATUS The Setpoint status indicates the setting of the setpoint for the room temperature of a CELL The setpoint is same value as that indicated on the remote controller of the CELL This Setpoint status of a CELL indicates not only result of a control command from this Gateway but also result from other controllers For example the setpoint status reflects change of state of a CELL from the remote controller as well as from this Gateway As above mentioned in a rare case that this Gateway fails to receive the change of state broadcast from
14. Option controller connected case of the previous SUPERLINK communication systenj SC WGWNA B Product Specification Ver 10 Document No 157209025 Deci O00 1 2009 2 2 ETHERNET NETWORK 1 Private Ethernet As shown in Fig 2 1 recommended network environment for this Gateway system is the private local Ethernet line for exclusive use In other words no network nodes except this Gateway and the PCs for this system are connected to the Ethernet line Connection to the Intranet i e office LAN or the Internet may be possible under responsibility of the network administrator on the site and with paid engineering work Network wiring for the Ethernet line shall be done according to each network equipment manufacturer s wiring specifications This Gateway does not require special wiring for the Ethernet line and assume the following Ethernet specifications 10BASE T or 100BASE TX twisted pair cable Ethernet ThelP address for this Gateway has been set before shipment as the following initial address for the CLASS C PRIVATE ADDRESS Initial IP Address 192 168 0 110 Alternation of the IP address of this Gateway has to be done using the configuration function of this Gateway This procedure requires technical knowledge on computer networks 2 Network Security This Gateway does not have any special measures for the Ethernet network security such as counter measures for evil attacks from the network network virus and soon It i
15. POWER CONSUMPTION CALCULATION FILE DOWNLOAD SCREEN SC WGWNA B Product Specification Ver 10 Document No 157209025 Dec 1 2009 6 20 POWER CONSUMPTION CALCULATION PERIOD DEFINITION SCREEN This screen defines Normal charge rate time period of a day for the power consumption calculation function This screen can be reached from the configuration screen In this power consumption calculation a day is divided into two periods that is the normal charge rate time and special chargeratetime input time data of this screen defines the normal charge rate time which is normally day time office hours E Accounting Period Time Microsoft Internet Explorer File Edit View Favorites Tools a Oo BRO F amp Address a http 192 168 0 110 en paytimezone php Nj a c3 Links North South Overview Monitor Control Commnand Schedule Control System Stop Release Configuration Menu SUPERLINK WEB GATEWAY Accounting Period Time MITSUBISHI INDUSTRIES LTD Normal charge rate time e ko m ke Set XJ Local intranet Fig 6 20 ACCOUNTING PERIOD TIME SETTING SCREEN 39 SC WGWNA B Product Specification Ver 10 Document No 157209025 Deci O00 1 2009 7 CONTROL amp MONITOR FUNCTIONS 7 1 ON OFF COMMAND The On Off command is a control function to switch a CELL indoor unit On and Off The operation result of this command is the same as the On Off from a remote c
16. WEB server URL http 192 168 0 110 ery The default IP address which is set at the shipment is 192 168 0 110 In case that thelP address has been changed the new IP address should replace with the default IP address of 192 168 0 110 This screen of the SC WGWNA B Gateway is for user authentication This Gateway defines the following three categories of user operation rights 1 Administrator User 2 Control U ser 3 Monitor User The first category of the users has the all administration rights of the WEB server control rights and monitor rights of the system The second category of the users has the control and monitor rights of the system Thethird category of the users has the monitor rights only In other words PCs for this Gateway system are categorized by the PC users of the above mentioned categories TheUserlD and the Password can be changed in the Authentication Configuration screen that will be mentioned later in this document The default Userl Ds and Passwords are set when factory shipment as follows 1 Administrator U ser User ID Admn Default Password 123456 2 Control User User ID Gortroller Default Password 123456 3 Monitor User User ID User Default Password 123456 In case that more than one WE B Gateways are linked by the Communication Configuration written in the dause 6 10 of this document the name of the WEB Gateway which an operator now tries to log in is displayed at the center of this screen
17. corresponding screen of the other linked WE B Gateway This WEB Gateway recognizes the input name as its own Link Name when theinput IP address matches its own IP address Then its own Link Name Tab is displayed with dark gray Link Configuration Microsoft Internet Explorer File Edit View Favorites Tools Help Address http 192 168 0 1 10 enslinkgwconfig php West North South Overview Monitor Control Commnand Schedule Control System Stop Release Configuration Menu SUPERLINK WEB GATEWAY Link Configuration h MITSUBISHI Link _ danke fameits Tanke ame East West _ North South IP Address IP Address IP Address IP Address 192 168 0 110 1921680111 192 168 0 112 1921680113 Attention Don t input 0 at the front of each octet Ex Correct 192 168 1 110 Incorrect 192 168 001 110 2 Done Local intranet Fig 6 10 LINK CONFIGURATION SCREEN 29 SC WGWNA B Product Specification Ver 10 Document No 157209025 O00 1 2009 6 11 SECURITY CONFIGURATION SCREEN This is the screen in which the IP address filtering can beset This screen can be accessed only by the Administrator User By input one or more IP addresses to the input dialog box of this screen the only PCs with this IP address can become the WEB browser for this Gateway In the default state none of the IP addresses have been
18. definition is provided by the PAC information file Theinformation file must be set before the test operation of this Gateway This PAC information file is memorized by the non volatile memory of this Gateway once is uploaded 3 Max number of indoor units and option controller 3 1 New SUPERLINK communication system In general case Fig 2 1 1 2 1 2 the maximum number of indoor units outdoor units and option controller connected is shown in bellow Nunber of indoor units Nunter of outdoor units Nunber of option controllers Max 64 units x 2 SUPERLI NK system Mx 128 uni ts Max 12 units x 2 SUPERLI NK system Max 24 uni ts Connected to each SUPERLI NK system SL3N SL2N SLIN 1 1 4 2 0 4 0 2 4 In the case of SL2N SL3N it is necessary to erase registration of non connected inside unit For SL2N and SL3N change is required for the setup deprived of the right of instruction of Remocon control Lock Unlock In the case of 128 indoor units on one SUPERLINK Fig 2 1 3 the maximum number of indoor units outdoor units and option controller connected is shown in bellow Nunber of indoor units Max 128 units x 1 SUPERU NK system 128 units Nunteer of outdoor units Max 24 units x 1 SUPERU NK 24 units Nuntber of option controllers Connected to SUPERLI NK system SL3N SL2N SLIN 1 2 8 2 0 8 0 4 8 Same as above
19. v a Select Date Fi al _ mm al EN 2 ma x E amp l Done zzm internet Fig 6 14 MASTER SCHEDULE CONFIGURATION SCREEN 33 SC WGWNA B Product Specification Ver 10 Document No ISTZ09025 Decl O00 1 2009 6 15 SCHEDULE CONTROL SCREEN This screen is for temporary alternation of the Master Schedule of each CELL This screen can be reached from the home page of this WEB server that is the Overview Monitor screen Not only the Administrator user but also the Controller user can get into this screen At first the today s Schedule Control screen for the smallest number CELL will appear The specific Schedule Control screen will appear by selecting the CELL from the Air con CELL pull down menu and the date from the Schedule Date pull down menu which consists 7 days from today The default schedule is same as the Master Schedule Theuser can temporarily change the daily operation schedule of the CELL without influencing on the corresponding Master Schedule The schedule items and acceptable values arethe followings Item Value On Off Blank No operation On Off Mode Blank No operation Auto H eat Cool Fan Dry Fan Speed Blank No operation Powerful High Medium Low Set Temperature Blank No operation 18 0 18 5 30 0 deg Celsius Remocon Lock Blank N o operation Lock Unlock The combination of up to 5 items that is On Off M ode FanSpeed SetTemperature
20. 00 1 2009 7 14 ROOM TEMPERATURE STATUS The Room Temperature status indicates the sensor value of the inlet air temperature of a CELL In case that a CELL consists more than one indoor units the sensor value of the indoor unit that has the smallest SUPERLINK address among running indoor units of the CELL The range of the room temperature status value is from 0 degree to 35 degrees Celsius with 0 25 degree step the case of below degree or above 35 degrees the room temperature status indicates 0 or 35 degrees respectively As above mentioned in a rare case that this Gateway fails to receive the change of state broadcast from an indoor unit the change of the room temperature status indication would delay for about 1 minute at the worst case of Document 42
21. 9 Fig 2 1 4 shows a basic case of the previous SUPERLINK communication system diagram of connection between the building management system host computer the WEB Gateway and the SUPERLINK control networks Control amp Monitor PC Explorer Previous System Ethernet 10BASE T or 100BASE TX Pulse signal wirings connecting with a HUB or a cross cable pulse Gas M amp ttrreter Pl JTL WW WEB Gateway p2 Ww SC MGWNA B P4 W SUPERLINK network SUPERLINK Gas meters and Watt meters should be the followings CELL CELEA48 eee MWth non voltage contact pulse Tacos Een 1 transmitters nit nit Pulse width 100 ms more UO rx R zi CERE gt IU 1 IndoorUnit EE 10 1 iR CELL eee IndoorUnit IndoorUnit 0 2 1 2 CELA Tess IndoorUnit 0 46 5 1 1 IndoorUnit IU 47 CELL No allocation From CELL to CELL 95 can be allocated Skipping CELL No is acceptable OutdoorUnit Nurrber of indoor units for one SUPERLINK network 48 indoor units be connected case SLIN or SL2N etc is not connected Nurrber of outdoor units for SUPERLINK doorUni network OU 11 1 12 recommended Fig 214 System Diagram Basic case of the previous SUPERLINK communication systenq SC WGWNA B Product Specification Ver
22. ERLINK network SUPERLINK network Gc meters and Watt meters should be the followings GELL 0 CELL 48 _ Mith non voltage contact pulse 1 transmitters ndoorUnit Indoor Pulse width 100 ms or more 0 0 mR PAR gt IU 1 IndoorUnit E E IU 1 IR T esse IndoorUnit IndoorUnit 0 2 10 2 IndoorUnit 2 indoorUnit 0 62 1 10 62 S18 IndoorUnit IndoorUnit IU 63 IU 63 CELL No allocation FromCELL 0 to CELL 95 can be allocated 5 25 Sa Skipping CELL No is acceptable OutdoorUnit OutdoorUnit Nurrber of indoor units for one SUPERLINK OU 0 OU 0 network 7 E Max 64 indoor units can be connected Nurrber of outdoor units for SUPERLINK network re TUN Max 12 recorrmended Fig 211 SystemDiagram Basic case of the new SUPERLINK systenq SC WGWNA B Product Specification Ver 1 0 Document No 157209025 Deci O00 1 2009 Fig 2 1 2 shows a case of the new SUPERLINK communication system diagram of connection between the building management system host computer the WEB Gateway and the SUPERLINK control networks along with SUPERLINK option controllers such as SLIN 51 2 51 TheSC ADN adapter should be used for connection of MHI s single type packaged air conditioner models Cortrol amp Monitor PC Max SPORT Explorer
23. In the case of restoring the backup file to the SC WGWNA B again the file can be uploaded by the Calendar Schedule Backup File Upload screen as shown in below Immediately after uploading the backup file the gateway will reboot automatically and make the backup file in effect Calendar Schedule Backup File Upload Microsoft Internet Explorer File Edit View Favorites Tools Address El http 192 168 0 110 en scheduleupload php 5 Go North South Overview Monitor Control Commnand Schedule Control System Stop Release Configuration Menu SUPERLINK WEB GATEWAY Calendar Schedule Backup File Upload MITSUBISHI HEAVY INDUSTRIES LTD When the backup file is uploaded the WEB Gateway will be automatically rebooted imediately Calendar Schedule Backup File _ _ _ JC Browse Local intranet Fig 6 16 CALENDAR SCHEDULE BACKUP FILE UPLOAD SCREEN 35 SC WGWNA B Product Specification Ver 10 Document No ISTZ09025 Decl O00 1 2009 6 17 DATE TIME SET SCREEN This screen is for setting the current Date and Time for the WEB server WEB server instead of the PC s operating system date and time This screen can be reached from the Configuration Menu screen Only the Administrator user can get intothis screen Since the schedule control makes use of this current time resetting once a while is necessary for exact operation This Date and Timeis for Date Time Set Microso
24. RemoconL ock can be scheduled for each schedule time The total number of the schedule items multiplied by the schedule times should be less than 20 for one screen The edited schedule data in this screen will be stored by clicking the Set button The edited schedule data will be cancelled by clicking the Undo button Also the data be copied to that of another CELL by dicking the Copy button Schedule Control Microsoft Internet Explorer File Edit Favorites Tools Help Bae FH eO BARBRA amp l http 192 168 0 110 en schedule php West North Overview Monitor Control Command System Stop Release Configuration Menu SUPERLINK WEB GATEWAY Schedule Control 3 MITSUBISHI Nov 12 2009 16 05 Time On Off Mode Fan Speed Set Point Remocon Lock On Air con Name Room 01 v Schedule Date Nov 12 v Set Of v This schedule will be copied to Destination Air con Name Schedule Date ga Fa lt 1 amp Done Fig 6 15 SCHEDULE CONTROL SCREEN SC WGWNA B Product Specification Ver 10 Document No 157209025 Dec 1 2009 6 16 CALENDAR SCHEDULE DATA BACKUP SCREEN The calendar schedule data can be backuped as a compressed binary data file by this screen The both data will be compressed into a tgz type file and downloaded automatically from the Calendar Schedule Backup File Download screen
25. Room41 Room 42 This room is Cell 74 P Room 45 I Room 47 Room 48 m Room 51 BB Room 52 BS noon 53 B Room 54 peration Status Fan O b wi ES f Failure Statu Room 57 4 Room 58 Room 59 oom 60 lure Status Normal 63 64 x Room 65 ES Room 66 Fan Speed Hi Set Point 25 00deg d Room 69 ER Room 70 B Room 71 8B Room 72 Room Temperature 25 00deg Room 75 BS Room 76 Room 77 oom 78 Ri Lock Unlock SUR ee Ha oom 81 82 A Room 83 A Room 84 Filter Sign Of Error Code Room 87 Room 88 BIB Room 89 Room 90 Room 93 T fe Room 94 95 le Room 96 J En Moy Mor E Local intranet Fig 63 INDIVIDUAL MONITOR SCREEN 22 SC WGWNA B Product Specification Ver 10 Document No ISTZ09025 Decl O00 1 2009 64 CONTROL COMMAND SCREEN The Control Command screen is for control input operation toeach CELL This screen can be accessed by the Administrator User or the Controller User as mentioned above The Monitor User can not access to this screen By clicking the link name character string for this screen on the Overview Monitor screen this Control Command screen will appear Normally it takes several seconds to compose the Control Command screen But it may take more time depending on the Ethernet network environment and other factors Each control item of each CELL has the pull down menu in the Control Command screen Selecting control value
26. The Overview Monitor screen will appear after the login WEB Control amp Monitor System Microsoft Internet Explorer File Edit View Favorites Tools Help Address http 192 168 0 110 en Local intranet Fig 6 1 LOGIN SCREEN 18 SC WGWNA B Product Specification Ver 10 Document No 157209025 Deci O00 1 2009 6 2 OVERVIEW MONITOR SCREEN This screen is for monitoring the overview of the whole PAC system on the one screen short names for the installation place On Off OperationM ode status icons and Failure status icons of up to 96 CELLS are displayed as an array on this screen The whole status information can be displayed without scroll manipulation if the Internet Explorer widow size is set to larger than 1024 by 768 pixels The length of the character string for the short name for a CELL is upto 16 characters The character string indicates place of the CELL for example ROOMI23 or 2F EAST The character string can be input on the PAC information configuration screen that will be explained later This Overview Monitor screen will appear immediately after the login and supposed to be the home screen of the WEB server while the Gateway is running This screen has the links to other screens of Control Command screen System Stop screen and Configuration Menu screen By clicking each screen link each corresponding screen will appear This Overview Monitor screen als
27. U A s ws EE _ West North South Air con Control Schedule Control System Stop Release Configuration Menu SUPERLINK WEB GATEWAY Overview Monitor Screen MITSUBISHI A Room 01 A Room 02 A Room 03 Room 04 I Room 05 Room 06 ES Room 07 Room 08 Er Room 09 GB Room 10 oom 11 Room 12 BS Room 13 S Room 14 E Room 15 GS Room 16 ry oom 17 4 18 ry Room 19 4 Room 20 A Room 21 A Room 22 Room 23 Room 24 x Room 25 gx Room 26 e Room 27 E Room 28 ak Room 29 a8 Room 30 Room 31 BB Room 32 BS Room 33 BS Room 34 BS Room 35 IS Room 36 ry Room 37 ry oom 38 Doom 39 gt 40 A oom 41 A Room 42 A Room 43 A Room 44 B Room 45 BB Room 46 Broom 47 E Room 48 88 Room 49 50 ER Room 51 Er Room 52 S Room 53 5 54 E Room 55 S Room 56 4 57 4 Room 58 g oom 59 ry Room 60 A 61 A Room 62 A Room 63 A Room 64 Room 65 gx Room 66 B Room 67 E Room 68 BS Room 69 BB Room 70 EB Room di BE Room 72 Room 73 E Room 74 Room 75 amp Room 76 4 Room 77 Room 78 Drom 79 8 zoom IS Room 81 A Room 82 A Room 83 A Room 84 Room 85 Room 86 e Room 87 Room 88 8 89 aK Room 90 ER Room 91 BE Room 52 E Room 93 epe Room 94 fa if Room 95 epe Room 96 A Auto ES Heat E Cool E Fan 4 Dry Beane R No Data v Local intranet Fig 62 4 OVERVIEW MONITOR SCREEN 19 SC WGWNA B Product Specification Ver 10 Document No ISTZ09025 Decl O00 1 2009 In casethat the Ala
28. access tothis screen By clicking the System Stop Release button the Gateway automatically sends the Off commands and the Remocon Lock commands to all the CELL at once Consequently all the indoor units under this Gateway immediately stop and set as the Remocon Lock mode By dicking the Release button on this screen all the indoor units are released to resume the Remocon Unlock mode In case that the optional SUPERLINK controller such as 51 1 or SL2N is also connected the above mentioned Remocon Lock command will be overridden by the optional SUPERLINK controller s remocon lock unlock setting Therefore this System Stop Release function is not recommended to use with optional controllers a System Stop Release Microsoft Internet Explorer File Edit View Favorites Tools Help Q Address http 192 168 0 110 en systemstop php I South Overview Monitor Control Commnand Schedule Control Configuration Menu SUPERLINK WEB GATEWAY System Stop Release MITSUBISHI MEAVY INDUSTRIES LTD Currently System is in the normal operation System Stop commnad will be sent by depressing the button below Caution Please do not depress the button below except for emergency System Stop Local intranet Fig 6 5 SYSTEM STOP SCREEN Remocon Lock control serves all functions Unlock after release from forced stop It is because the remocon control enabled the return to the
29. an indoor unit the change of the setpoint indication would delay for about 1 minute at the worst case 7 11 FAN SPEED STATUS TheFan Speed status indicates the setting of the indoor unit s fan speed of a CELL Thefan speed is same as that indicated on the remote controller of the CELL This fan speed status of a CELL indicates not only result of a control command from this Gateway but also result from other controllers For example the fan speed status reflects change of state of a CELL from the remote controller as well as from this Gateway As above mentioned in a rare case that this Gateway fails to receive the change of state broadcast from an indoor unit the change of the fan speed indication would delay for about 1 minute at the worst case 7 12 REMOCON LOCK UNLOCK STATUS The Remocon Lock Unlock status indicates the setting of the remocon as reject mode or accept mode setpoint for the room temperature of a CELL The rmocon lock unlock status is same as that indicated on the remote controller of the CELL 7 13 FILTER SIGN STATUS The Filter Sign status indicates whether the filter sign time up indication on the remote controller on or off As above mentioned in a rare case that this Gateway fails to receive the change of state broadcast from an indoor unit the change of the filter sign status indication would delay for about 1 minute at the worst case 41 SC WGWNA B Product Specification Ver 1 0 Document No 157209025 Deci O
30. ce ee the te eet 1 consumption for each Air Con CELL in the specified period OUTPUT DATA c Daily energy consumption of air conditioners for each meter save group P1 P4 9 d Daily operating time minutes and energy consumption for each 1 Air con CELL air conditioner s HD Text Lu nat e Monthly operating time hour and energy consumption for each Air con CELL air conditioner s Customer s software Cal cul ati ng the ai r condi ti s energy charge Printing out the bill of tenants 10 SC WGWNA B Product Specification Ver 10 Document No 157209025 Deci O00 1 2009 3 Pulse Input Signal Specifications The electrical specification of the pulse signal of the Watt meter or Gas meter is as follows Pulse generator of the Watt meter O Non voltage contact Close for pulse Pulse width of the Watt meter 100ms 500ms DC supply voltage from this gateway DC24V DC supply current from this gateway 0 20mA Insulation type of this gateway s input circuit Photo coupler insulation 4 Basic Charge Set up The power consumption of the air conditioning unit when not in use in between operation at night etc is not divided proportionally in each air conditioning cell t is recommended to set the power rate during OFF period as the basic charge of each cell 11 SC WGWNA B Product Specification Ver 10 Document No 157209025 Ded
31. e models of indoor units cannot be set to Powerful and cannot be display to it 13 SC WGWNA B Product Specification Ver 1 0 Document No 157209025 Deci O00 1 2009 4 HARDWARE SPECIFICATIONS 1 Power Supply AC single phase 100V 240V 10 15 50 60Hz 2 Operation Temperature Ambient Temperature 0 to 40 degrees Celsius Relative Humidity Max 85 RH without dewing 3 Storage Temperature Ambient Temperature 10 to 50 degrees Celsius Relative Humidity Max 85 RH After 48 hours from out of storage dewing should not exists 4 Power Blackout Compensation This Gateway does not have a battery circuit for power blackout recovery If blackout or manual power off occurs for more than 30 msec the monitoring data and the setting of each CELL indoor unit such as the operation mode or set point temperature may disappear This gateway periodically writes the Remocon Lock Unlock command of the CELLs to the non volatile memory at every 10 minutes If the power supply is cut off this gateway will restore the Remocon Lock Unlock command at least 10 minutes before when it restarts 5 Appearance Outline drawing Fig 4 1 on the following page Outline dimensions 260 W x 200 H x 79 D mm Color Black 14 SC WGWNA B Product Specification Ver 1 0 Document No 157209025 Dec j 1 2009 MA 3135 WNT 1834s bid b 8 8 i i KAN amp
32. e used Materials for wiring the Ethernet such as cables or HUBs are not included this Gateway s product package Thetype of the HUB may be ordinary office LAN use 5 4 SUPERLINK CABLE Shielded wire double core 0 75 20 1 25 Max 1000m per line distance 1000m Total wire length 1000m Note 1 When this Gateway is used use a shielded wire for the SUPERLINK signal wire Ground both ends of the shielded wire Please wire the ground of the Gateway at 2 Ground position Note 2 If the indoor and outdoor units connected to the network are all compatible units with New SUPERLINK a total wire length of 1500m per lineis possible maximum distance 1000m However be sure to use a 0 75mm wire diameter if the total wire length exceeds 1000m For further information please contact your sales representative or dealer 5 5 PULSE INPUT LINE CABLE 1 Size of cable 10 75 2 0square mm 2 Max length of wiring 200m channel 3 Suggested cable material For example 2 cores 17 SC WGWNA B Product Specification Ver 10 Document No ISTZ09025 Decl O00 1 2009 8 WEB SERVER FUNCTIONS The WEB server functions mean screen making functions of the Internet Explorer on the PCs which are connected with the SC WGWNA B Gateway 6 1 LOGIN SCREEN In order tologin to the WEB server of this Gateway input the following URL intothe WEB browser that is the Internet Explorer on the Control amp Monitor PC
33. ed even in the case of power off This yearly calendar does not distinguish the year therefore the setting can be used in the following years In case that more than one WE B Gateways are linked this yearly calendar should be set for each Gateway By dickingthe linked Gateway name on the first line of the screen the corresponding yearly calendar will appear Calendar Configuration Microsoft Internet Explorer File Edit View Favorites Tools ay Address E http 192 168 0 110 en calendar php_ m Links gt West North South Overview Monitor Control Commnand Schedule Control System Stop Release Configuration Menu SUPERLINK WEB GATEWAY Calendar Configuration E MITSUBISHI Sun Mon Tue Wed Thu Fri Sat Select Month Jan 2008 1 2 3 4 i Weekda Weekday x Weekday Weekday Weekday 7 7 8 9 10 11 Holiday Weekday Weekday x Weekday Weekday Weekday Holiday 17 18 Holiday Holiday ense T x Weekday Holiday Weekday Weekday Weekday Weekday 28 29 30 31 Weekday x Weekday Weekday x Weekday x Done Internet Fig 6 13 CALENDAR CONFIGURATION SCREEN 32 SC WGWNA B Product Specification Ver 10 Document No 157209025 Dec j O00 1 2009 6 14 MASTER SCHEDULE CONFIGURATION SCREEN This scr
34. een is for setting the Master Schedule of each CELL A Master Schedule is the name of the daily operation schedule which is mentioned in the previous page This screen can be reached from the Configuration Menu screen Only the Administrator User can get intothis screen A Master Schedule is a default day operation schedule of a specific CELL Each CELL can have up to 10 Master Schedules corresponding to the day category that is Monday Tuesday Wednesday Thursday Friday Saturday Sunday Holiday Specialday1 and Specialday2 CELL operation will be scheduled by this Master Schedule unless temporarily modified by the Schedule Control function At first the Master Schedule configuration screen for the smallest CELL No will appear The specific Master Schedule will appear by selecting the CELL from the Air con CELL pull down menu and the day category by the Select Date pull down menu The schedule items and acceptable values arethe followings Item Value On Off Blank No operation On Off Mode Blank No operation Auto Heat Cool Fan Dry Fan Speed Blank No operation Powerful High Medium Low Set Temperature Blank No operation 18 0 18 5 30 0 deg Celsius Remocon Lock Blank No operation Lock Unlock The combination of up to 5 items that is On Off Mode FanSpeed SetTemperature RemoconL ock can be scheduled for each schedule time Thetotal number of the schedule items multiplied by the schedule ti
35. eries MHI s Multi GHP series SC ADN adapter Separate PAC series When the SC ADNs are used some functions will become invalid The detail explanation of the limitations for the SC ADN will appear in the later version of this document Do not set the set point at 0 5 C intervals in case this product is used with RCD type wired remote controller It would cause malfunction of the wired remote controller Please make sure to set at 1 C intervals SC WGWNA B Product Specification Ver 10 Document No 157209025 Deci O00 1 2009 2 AI R CON CELL A group of indoor units connected by the remocon lineis called an Air con CELL in this WEB Gateway system An Air con CELL is defined as a logical group of indoor units for control amp monitor from this WEB Gateway IntheFig 2 1 1toFig 2 1 5 an Air con CELL is indicated by a surrounding dashed line The indoor units of the CELL should be on the same SUPERLINK network Butthe CELL identification numbers can be allocated over the SUPERLINK networks as shown in Table 2 4 1 and 2 4 2 below Sending a control command to a CELL is equal to sending the control command to every indoor unit of the CELL Itis possible to control and monitor each individual indoor unit by defining a CELL as an indoor unit All indoor units in the same CELL must be connected by the same remote controller that is a remocon group connection The CELL grouping definition is common to all the functions of this Gateway The CELL
36. figuration manual of the WEB Gateway Internet Explorer WEB Gateway SC WGWNA B SUPERLINK network Control amp Monitor PC Hm 00000000 System Ethemet 10BASE T or 100BASE TX Pulse signal wirings onnecting with a HUB or a cross cable yf pulse Gas Mattmeter 1 JL P2 A W Q P4 W Gas meters and Watt meters should be the followings SUPERLINK network With non voltage contact pulse rrr transmitters ndoorUnit In this cese Pulse width 100 ns or more 0 0 R d IndoorUnit IU 1 CELL 1 MIR In case that an out door uni t of conti nati on syst ens IndoorUnit R is used nore than 65 indoor units night be connect ed 0 2 to SUPERLI NK system quee In this case SG is used in one SLPERLI NK H systemnenti oned here CELL 5e Grhervise it i s reconmended that SC B i s used TU ID Uo two SUPERLI NK systens ti nd gt IU 127 CELL No allocation From CELL 0 to CELL 95 can be allocated Skipping CELL No is acceptable Nurrber of indoor units OutdoorUnit Max 128 indoor units can be connected Nurrber of outdoor units Max 24 recommended OutdoorUnit OU 23 Fig 2 4 3 System Diagram 128 indoor units on one SUPERLINK communication syst New SUPERLINK communication system SC WGWNA B Product Specification Ver 10 Document No 157209025 Dec 1 200
37. ft Internet Explorer ek File Edit View Favorites Tools iy ee EC BREDA Address http 192 168 0 110 en date php E Ee ws West North South Overview Monitor Control Commnand Schedule Control System Stop Release Configuration Menu SUPERLINK WEB GATEWAY Date Time Set MITSUBISHI Jun 01 2009 19 23 Caution Drastic change of the clock might influence the accounting data Jm 101 09 3 Set Done Local intranet Fig 6 17 DATE TIME SET SCREEN 36 SC WGWNA B Product Specification Ver 10 Document No 157209025 000 1 2009 6 18 NTP CONFIGURATION SCREEN This screen is for setting the automatic synchronization to an NTP time server for the WEB gateway s dock Only the Administrator User can access to this screen ThelP address of the NTPtime server is input to the IP address column of this screen and the desired time difference with UTC time should beset The time difference can set the range from minus 11 hours and 45 minutes to plus 14 hours and 45 minutes at intervals of 15 minutes E nu Configuration Microsoft Internet Explorer File Edit View Favorites Tools Help O O 2o P ewe Address 2 http 192 168 0 110 en ntpconfig php hd Ee North South Overview Monitor Control Commnand Schedule Control System Stop Release Configuration Menu SUPERLINK WEB GATEWAY NTP Configuration MITSUBISHI HEAVY INDUSTRIES LTD
38. in Password Autheticaion eeccccce Administrator M Controller LLLLLLLLI Controller M User v Administrator Controller User MITSUBISHI WEAVY INDUSTRIES LTD Local intranet Fig 6 12 PASSWORD CHANGE SCREEN 31 SC WGWNA B Product Specification Ver 10 Document No ISTZ09025 Decl O00 1 2009 6 13 CALENDAR CONFIGURATION SCREEN This screen is for setting yearly calendar of this WEB Gateway This screen can be reached from the Configuration Menu screen Only the Administrator User can ge intothis screen At first the current month s calendar will appear The calendar of a specific month will appear by selecting a month from the Select Month pull down menu Time for composing the screen will depend on the network environment and other factors The Administrator can set each day as Weekday Holiday Special 1 or Special 2 For a Weekday the daily operation schedule corresponding day of the week will be related to the date of this yearly calendar For a Holiday a Special 1 or a Special 2 the corresponding daily operation schedule will be related tothe date After editing a specific month the setting will be stored by clicking Set button In case that the Undo button clicked before clicking Set edited contents will disappear This Gateway has only one yearly calendar which is common toall CELLs The setting for this yearly calendar will be memoriz
39. me as setting from a remote controller The range of fan speed selection is Low Medium High Powerful 7 5 REMOCON LOCK UNLOCK COMMAND The Remocon L ock U nlock command is a control function to set the remocon as reject mode or accept mode Manipulation of all switches on the remote controller such as On Off switch Operation Mode switch and so on are rejected or accepted according with this command s setting In the case of using a SUPERLINK optional controller such as the SL2N or the SL3N along with this Gateway please make the setup of the remocon operations Lock U nlock from other optional controller invalid Refer to each installation sheet instruction manual etc for the setting method Otherwise the CELL which is set as different remocon reject mode will alternate its Lock U nlock mode back and forth forever at the interval of several tens of seconds This will cause a serious malfunction In preparation for the case of power off the value of this function is written to the non volatile memory at every 10 minutes and is restored when the gateway restarts The action is different from other functions 7 6 FILTER SIGN RESET COMMAND TheFilter Sign Reset command is a control function to reset the filter sign time up indication on the remote controller of the CELL 7 7 FAILURE STATUS TheFailure status indicates the status of the failure LED on the remote controller for the CELL This status indicates if the red LED of the remote cont
40. mes should be less than 20 for one screen If the schedule of 7 days starting from Today is to be changed load Master Schedule at the Schedule Control screen The edited schedule data in this screen will be stored by clicking the Set button The edited schedule data will be cancelled by clicking the Undo button Also the data be copied to that of another CELL by dicking the Copy button Master Schedule Configuration Microsoft Internet Explorer File Edit View Favorites Tools Help ay AAG F REG amp EB DA Address a http 192 168 0 110 en schedulemaster php Links West North South Overview Monitor Control Commnand Schedule Control System Stop Release Configuration Menu SUPERLINK WEB GATEWAY Master Schedule Configuration oe MITSUBISHI HEAVY INDUSTRIES LTD Time OnOff Mode Fan Speed Set Point Remocon Lock 07 55 Y Heat x High 250 x Unlock es Air con Cell Room 01 v 12 ko Of v vj Select Date Monday v 55 On v 230 orm 5j Set v Ls Ka This schedule will be copied to Destination lt lt E I e x Jr EIEI Jr Js Je e JE E lt lt E lt lt EE ES E E EE E E Air con Cell
41. nand Schedule Control System Stop Release Configuration Menu SUPERLINK WEB GATEWAY Air con Cell Configuration MITSUBISHI INDUSTRIES LTD SL Sys No SL Address Accounting Type Capacity kW Air con Cell No Air con Cell Name Description 1 000 MULT 56 v coo v Room 01 This room is Cell 00 1 1701 MULTI M 5 6 iw C01 Room 02 This room is Cell 01 51 U02 MULTIT 56 c02 Room 03 This room is Cell 02 51 1703 Mum 58 C03 Room 04 This room is Cell 03 51 104 MULTD vj 55 v Room 05 This room is Cell 04 51 105 MULTI B0 Room 06 This room is Cell 05 1 1706 MULTI2 x 80 Room 07 This room is Cell 06 51 U07 80 v Room 08 This room is Cell 07 1 RUN STOP 112 Reom09 This room is Cell 08 1 109 RUN STOP 11 2 4 Room 10 This room is Cell 09 51 1710 111 2 4 Room 11 This room is Cell 10 1 7711 RUN STOP 11 2 A Room 12 This room is Cell 11 S U12 RUN STOP Room 13 This room is Cell 12 51 U13 RUN STOP v 7 14 This room is Cell 13 1 1014 Room 15 This room is Cell 14 Accounting Type MULTI Accounting according to the amount of refrigerant flow MULTI2 Accounting according to the thermo ON OFF RUN STOP Accounting according to the unit operating time Local intranet Fig 6 7
42. ns technical service work such as dispatching engineers to the site the address allocation planning work configuration of this Gateway trial operation of the system and soon These engineering works may be paid services 1 4 CUSTOMIZE WORK This WEB Gateway is a kind of ready made product Customization of the functions of this Gateway will not be supplied 1 5 CAUTION THAT PERFORMING OF THE MONTHLY CALCULATION We can not compensate when monthly calculation was not possible by the trouble of this Gateway Becausethe monthly calculation by this data not conform to OIML International Organization of Legal Metrology we cannot apply to public business Please prepare the PC spreadsheet such as EXCEL a printer a wattmeter a gas flow meter that are required for calculation SC WGWNA B Product Specification Ver 10 Document No 157209025 Dec 1 2009 2 SYSTEM ARCHITECTURE 2 1 SYSTEM DIAGRAM Fig 2 1 1 shows a basic case of the new SUPERLINK communication system diagram of connection between the Control amp Monitor PC the WEB Gateway and the SUPERLINK control networks Internet Control amp Monitor PC 000 00000000 xplorer System Ethemet 10BASE T or 100BASE TX Pulse signal wirings connecting with a HUB or a cross cable pulse Gas M amp ttrreter JL Pl Ww WEB Gateway SC WGWNA B Cw C SUP
43. nt of the Individual Monitor window Therefore if an Individual Monitor window is left opened for a long time some part of the Overview Monitor screen loose a chance to notify changes of status for the packaged air conditioners This Gateway detects status changes of packaged air conditioners by the SUPERLINK broadcast communication packets from indoor units The Gateway inquires status changes to every indoor unit at the 1 minute interval as a backup for a case that the Gateway fails to receive the status change broadcast a rare case the status change of a CELL on the Individual Monitor screen might delay up to 1 minute Overview Monitor Microsoft Internet Explorer EJ E gt 7 oco kW Ug Address http 192 168 0 1 10 en statusall php x Go Links gt West North South Air con Control Schedule Control System Stop Release Configuration Menu SUPERLINK WEB GATEWAY Overview Monitor Screen 5 MITSUBISHI HEAVY INDUSTRIES LTD A A Room 01 A Room 02 A Room 03 A Room 04 I Room 05 V Room 06 Room 07 6 08 E oom 09 8 Room 10 Er Room 11 E oom 12 UE z3 Room 13 Room 14 Room 15 Room 16 D Room 17 18 l A Room 21 A Room 22 A Room 23 A Room 24 Eos oom 27 I Room 28 BB Room 29 ER Room 30 Individual Monitor Microsoft Interne E X ES E ee Room 33 Room 34 Room 35 Room 36 Room 75 BI Room 39 A
44. o indicates the System Off status by replacing the MITSUBISHI HEAVY Industries logo by the System Stop status indication The Overview Monitor screen is refreshed automatically by the interval of the reload period that can be configured from 1 second to 60 seconds Normally it takes less than 1 second to refresh the Overview Monitor screen But it may take several seconds to refresh the Overview Monitor screen depending on the Ethernet environment and other factors When refreshing the screen contents of the screen may blink because of the Internet E xplorer s intrinsic characteristic This Gateway detects status changes of packaged air conditioners by the SUPERLINK broadcast communication packets from indoor units The Gateway inquires status change to every indoor unit at the 1 minute interval as a backup for a casethat the Gateway fails to receive the status change broadcast In arare case the status change of a CELL on the Overview Monitor screen might delay up to 1 minute In case that more than one WEB Gateways are linked by the Communication Configuration written in the clause 6 10 of this document gateways are displayed like a tab menu A user can switch the screen to the corresponding screen of another WEB Gateway by dicking the link name Overview Monitor Microsoft Internet Explorer File Edit View Favorites Tools Help ay AAG BBE VDA dress http 192 168 0 110 enjstatusall php O
45. oad php ws West North South Overview Monitor Control Commnand Schedule Control System Stop Release Configuration Menu SUPERLINK WEB GATEWAY Air con Cell Configuration File Download MITSUBISHI Done S Local intranet Fig 68 2 AIR CON CELL CONFIGURATION DOWNLOAD SCREEN 27 SC WGWNA B Product Specification Ver 10 Document No 157209025 Deci O00 1 2009 6 9 COMMUNICATION CONFIGURATION SCREEN This screen configures the interval time of the WEB browser s screen refresh rate Only the Administrator User can access to this screen Therefresh interval time can be set from 10 second to 60 seconds At the factory shipment the interval has been set to 30 seconds About 60 seconds for refresh interval time is recommended when connecting with I ntranet Office LAN or the Internet In the case that the Control amp Monitor PC is Windows Vista check the Display Restart Message check box and fill in the Display Restart Message After box About 30 days is recommended and in this case Screen Refresh Interval is recommended to be set to 60 seconds around ThelP address and subnet mask of this gateway can be changed from this screen The gateway will be automatically rebooted if P address and subnet mask have been changed Thereis Buzzer ON check box in this screen By checking this box web browser P C s sound s the Alarm buzzer when an air conditioner s failure stop occurs Communication Buzzer Configurati
46. on Microsoft Internet Explorer File Edt View Favorites Tools ay BBE DBDA Address 8 http 4 192 168 0 110 en communicationconfig php West North South Overview Monitor Control Commnand Schedule Control System Stop Release Configuration Menu SUPERLINK WEB GATEWAY Communication Buzzer Configuration MITSUBISHI Screen Refresh Interval sec 30 lao 60 Buzzer ON IP Address 192 168 0 110 Subnet Mask 255 255 255 0 Default Gateway Display Restart Message Display Restart Message After days EI 1 90 Attention Don t input 0 at the front of each octet Ex Correct 192 168 1 110 Incorrect 192 168 001 110 E Done Local intranet Fig 6 9 COMMUNICATION CONFIGURATION SCREEN 28 SC WGWNA B Product Specification Ver 10 Document 157209025 Dec 1 2009 6 10 LINK CONFIGURATION SCREEN This screen configures the linkage with other WEB Gateways Only the Administrator User can access to this screen In case that more than one WEB Gateways are linked each other the Link Names for other Gateways should be input in this screen ThelP addresses of the linked WEB Gateways also have to be registered in the IP Address input columns of this screen The position of an input column determines the position of the Linked Name Tab on top of other screens By dicking a Link Name Tab the current screen will be switched to the
47. on does not reset the failure mode of the actual air conditioner This alarm buzzer will be stopped by resetting failure stop by a remote controller or an option controller such as SL2N Overview Monitor Microsoft Internet Explorer File Edit View Favorites Tools Help iy BaG FP eee B SHE DA Address http 192 168 0 110 en statusall php v Eco Wii 3 Ho S Air con Control Schedule Control System Stop Release Configuration Menu SUPERLINK WEB GATEWAY Overview Monitor Screen MITSUBISHI A Room 01 A Room 02 A Room 03 A Room 04 Room 05 Room 06 S Broom 07 Broom 08 BB Room 09 10 GB Room 11 BB Room 12 BS room 13 S Room 14 E Room 15 Broom 16 oom 17 roon 18 Room 19 Room 20 Room 21 22 23 24 Room 25 Room 26 Room 27 Room 28 8 Room 29 ER Room 30 BB Room 31 Room 32 Broom 33 BS room 34 Broom 35 Broom 36 koon 31 l Room 38 room 39 Broom 40 A Room 41 A Room 42 A Room 43 A Room 44 Room45 BB Room 46 ia 47 E Room 48 BS Room 49 50 Room 51 BB Room 52 Broom 53 S room 54 Broom 55 S room 56 B room 57 D Room 58 C Room 60 A Room 61 A Room 62 A Room 63 A Room 64 9 Room 66 Broom 67 Bi 68 69 70 88 Room 71 BB Room 72 S Room 73 74 E Room 75 S Room 76 Room 77 Room 78 8 Room 80 A Room 81 A Room 82 A Room 83 A Room 84 85 Room 86 5 Room 87 Room 88 8 89
48. ontroller of the indoor units In casethat a CELL consists of more than one indoor units in other words a remote controller group all indoor units are switched On Off simultaneously n casethat an indoor unit is defined as a CELL the unit is able to be switched On Off by this command If this Off command is sent to a CELL which is in theFailure status that is the red LED on the remote controller is turned on the Off command resets the Failure status in other words turns off the red LED regardless of the actual internal failure status of the unit When the On command is sent to the CELL in this situation the CELL would be switched on if the internal failure is removed or the CELL would go Failure indication again with the red LED on if the internal failure has not be removed 7 2 MODE COMMAND The Operation Mode command is a control function to set a CELL as AutoM ode Cooling Mode DryMode H eatingM ode or FanMode as same as setting from a remote controller In casethat a CELL consists of more than one indoor units all indoor units are set to the same Operation Mode simultaneously 7 3 SETPOINT COMMAND The Setpoint command is a control function to set the setpoint temperature of a CELL as same as setting from a remote controller Therange of setpoint is from 18 0 to 30 0 degrees Celsius by 0 5 degree step 7 4 FAN SPEED COMMAND TheFan Speed command is a control function to set the indoor unit s fan speed selection of a CELL as sa
49. operating condition before the forced stop In case of Remocon Lock remocon control were set Unlock before the forced stop it is necessary to set Remocon Unlock after release from forced stop 24 SC WGWNA B Product Specification Ver 10 Document No ISTZ09025 Decl O00 1 2009 6 6 CONFIGURATION MENU SCREEN This screen is displayed by clicking the Configuration M enu link on the upper right corner of each screen The configurations of the WEB Gateway such as PAC configuration can be selected from the menu a Configuration Menu Microsoft Internet Explorer File Edit View Favorites Tools Help Q oO 2na o P xeoo SADE Address http 192 168 0 110 en config php ws West North South Overview Monitor Control Commnand Schedule Control System Stop Release Configuration Menu SUPERLINK WEB GATEWAY Configuration Menu MITSUBISHI INDUSTRIES LTD Air con Cell Configuration File Upload Air con Cell Configuration File Download Air con Cell Configuration Calendar Configuration Master Schedule Configuration Calendar Schedule Backup File Upload Calendar Schedule Backup File Download Date and Time Configuration NTP Configuration Communication Buzzer Configuration Link Configuration Security Configuration Authentication Configuration Accounting File Download Accounting Period Time amp Done Local intranet Fig 6 6 CONFIGRATION MENU SCREEN 25 SC WGWNA B P
50. pas Product Specification Ver 10 ument No 157209025 Decl 0O00 1 2009 NEW SUPERLINK SYSTEM POWER CALCULATION WEB GATEWAY PRODUCT SPECIFICATION MODEL SC WGWNA B Product Drawing No PS7006 4017D Ver 1 0 Decerrber 1 2009 MITSUBISHI HEAVY INDUSTRIES LTD AIR CONDITIONING amp REFRIGERATION SYSTEMS HEADQUARTERS SC WGWNA B Product Specification Ver 10 Document No 157209025 Deci O00 1 2009 1 INTRODUCTION 1 1 SCOPE This product specification is applied to the WEB Gateway SC WGWNA B that connects a Control amp Monitor personal computer with the MITSUBISHI HEAVY INDUSTRIES SUPERLINK networks by the VEB 1 communication protocol This document describes the specifications of the product as for December 1 2009 Any contents of this document may be changed without prior notification 1 This product uses the WEB HTTP communication protocol which is widely used in the Internet However this Gateway is basically for usein a local LAN 1 2 STANDARD PACKAGE The standard package of this product includes the followings A Gateway SC WGWNA B unit User s manual Installation manual Power Consumption Calculation Utility Software CD ROM Thefollowing materials are not included in the standard package Personal computer systems for monitor and control LAN materials such as Ethernet cables switching hubs and firewalls 1 3 ENGINEERING WORK Engineering work mea
51. rm buzzer setting is ON as described in the dause 6 9 COMMUNICATION CONFIGURATION SCREEN the web browser will sound the alarm buzzer when a air conditioner failure stop occurs The volume of the buzzer is adjusted by the web browsing PC s volume setting The content of the alarm buzzer will not be customized The alarm buzzer goes not only at the overview monitor screen but also all other screens While this buzzer is sounding the MHI s logo on the upper right corner of the screen will be replaced by the red buzzer stop button By dicking this button all browser PC s buzzer will cease However this operation does not reset the failure mode of the actual air conditioner This alarm buzzer will be stopped by resetting failure stop by a remote controller or an option controller such as SL2N Overview Monitor Microsoft Internet Explorer BAA File Edit View Favorites Tools a BSE DA Address http 192 168 0 110 en statusall php West North South Air con Control Schedule Control System Stop Release Configuration Menu SUPERLINK WEB GATEWAY Overview Monitor Screen BuzzesTOP 0 A Room 02 A Room 03 A Room 04 X Room 05 Room 06 2 s Room 08 BS Room 09 GB Room 10 B8 Room 11 BB Room 12 amp Room 14 S Room 15 S Room 16 ME koom 13 18 Room 20 Room 21 A Room 22 A Room 23 24 fe Room 26 Room 27 0 Room 28 E Room 29 E Room 30 31 BE Room 32 Room 33 Room
52. roduct Specification Ver 10 Document No 157209025 Dec j O00 1 2009 6 7 PAC CONFIGURATION SCREEN This screen is for setting the place name and the short place name for each CELL This screen can be reached from the Configuration menu screen which is linked from the Overview monitor screen Only the Administrator User is able to access to this screen This screen shows the table of the CELL number the SUPERLINK channel number the SUPERLINK address of the indoor unit the input box for the place name and the input box for the short place name for the CELL Administrator can input a character string such as ROOML23 on the 5th FI oor for the place name of the CELL and also ROCM23 the short placename These names are automatically copied to the WGWcoonfig csv file for the PAC configuration file U pload Download function addition Accounting type and Capacity kW of each indoor unit can be defined in this screen in the case of power consumption calculation The Accounting type means a method of calculating operation data of the power consumption calculation Be sure to use a period mark as the decimal point mark instead of using a comma mark for input the capadity kW of indoor units Air con Cell Configuration Microsoft Internet Explorer File Edit View Favorites Tools Help o Prze oja Address http 192 168 0 110 en pacconfig php Y Be Links gt North South Overview Monitor Control Comm
53. roller is or off This status does not necessarily means the actual internal failure mode of the air conditioner If the Reset command is sent to the CELL whose Failure status is on that is the red LED is on the LED will turn off and the Failure status goes off regardless the actual malfunction cause has been removed or not The Gateway inquires status change to every indoor unit at the 1 minute interval as a backup for the cases that the Gateway fails to receive the status change broadcast SC WGWNA B Product Specification Ver 10 Document No 157209025 Deci O00 1 2009 7 8 ON OFF STATUS The On Off status function indicates the On Off status of a CELL In casethat at least one indoor unit is running the CELL the On Off status function indicates as On state In case that none of indoors is running in the CELL the On Off status function indicates Off state If one of the indoor units in the CELL is Failure state and therest of indoor units are running normally this function indicates On state and the Failure status function indicates Failure state for that CELL Thisis as same indication as that CELL s remote controller This On Off status of a CELL indicates not only result of a control command from this Gateway but also result from other controllers For example the On Off status reflects change of state of a CELL from the remote controller as well as from this Gateway As above mentioned in a rare case that this
54. s assumed that this Gateway will be used in the private Ethernet network If this Gateway is connected to an office LAN or the Internet there might be risks for injustice access and consequently this Gateway might be altered to be harmful communication source to other network nodes It is not the responsibility of this Gateway to such injustice network access and is exempted from compensation for the damage by such unexpected attacks 2 3 CONTROL amp MONITOR PC 1 PC Models Personal computers used as the WEB browsers for this system are out of the product supply scope The personal computers with relating software and hardware should be prepared by the customer Minimum performance conditions of the PC are as follows CPU dlock 500M Hz or above 2GHz or above recommended Main memory 512MB or above 1GB or above recommended Screen size 1024 x 768 or above 1280 x 1024 recommended 2 Operating System and WEB Browser The recommended Operating System and WEB Browser versions for both the Control and Monitor PC and the Monitor PCs are followings Operating System Microsoft Windows XP or 2000 Windows Vista SP1 See clause 6 9 WEB Browser Microsoft Internet Explorer version 6 or 7 This Gateway system executes only the Internet Explorer on the PC side The Gateway does not automatically download any executable codes to the PCs 2 4 AIR CONDITIONER CONNECTION 1 Packaged Air Conditioner M odels MHI s Multi KX s
55. s from the pull down menu one by one then clicking the Send button dispatches all the selected command values tothe CELLs at once When this screen is opened the status value indicated in each pull down menu is the current status for each CELL However these status values are not updated during this Control Command screen is opened That is the status values will not be changed even if a Failure occurs As mentioned above linked WEB Gateway names displayed like a tab menu on the first line of the screen Control Command Microsoft Internet Explorer File Edit Favorites Tools Help a yt Address 2 http 192 168 0 110 en paccontrol php West North Overview Monitor Schedule Control System Stop Release Configuration Menu High High 1 High High v Unlock ock SUPERLINK WEB GATEWAY Control Command Screen MITSUBISHI Air con Name On Off Mode Fan Speed Set Point Remocon Lock Filter Sign Failure ALL EM Ej Y J LN d or v High z F This screen is not refreshed automatically Done internet Fig 64 CONTROL COMMAND SCREEN 23 SC WGWNA B Product Specification Ver 10 Document No 157209025 Dec O00 1 2009 65 SYSTEM STOP SCREEN The System stop screen is for controlling the System Stop Release function of this Gateway The Administrator and the Controller User can
56. s gateway creates the binary data files as the input files for the SL3N BE Utility software on thePC Thedata process procedure is same as that of Mitsubishi Heavy Industries SC SL3N BE controller The binary data files are downloaded from this gateway to the PC by a LAN cable as shown below INPUT DATA D CELL definition binary file download En T Monthly data binary files download n i Ne ee 1 Conversion OUTPUT DATA sey CELL Definition File CSV format save CELL name CELL composition ell Monthly Data File CSV format Daily calculated values of the air conditioner s operation Tet forrat HD and daily cumulative pulses form the meters 1 Calculates the daily energy consumption of INPUT DATA air conditioners for each meter group Watt gas meter group definition 2 Calculates the daily operating time and the daily energy iv Watt gas meter pulse constant consumption for each air conditioner kWh pulse m pulse 3 Calcul the dail oc d the dail V Setting of the calculation period Calculates the daily operating time and the daily energy the end of the month the 20th of consumption for each Air Con CELL the month etc 4 Calculates the daily operating time and the daily energy
57. set in this screen This means the IP address filter has not been set that is any PC with any IP address can become a WEB browser of this Gateway a Security Configuration Microsoft Internet Explorer Eile Edit View Favorites Tools a O B amp M DA Address a http 192 168 0 110 en securityconfig php ws West North South Overview Monitor Control Commnand Schedule Control System Stop Release Configuration Menu SUPERLINK WEB GATEWAY Security Configuration d MITSUBISHI Pass IP Address 192 168 0 100 192 168 0 101 i Attention Don t input 0 at the front of each octet Ex Correct 192 168 1 110 Incorrect 192 168 001 110 Set Done Local intranet Fig 6 11 SECURITY CONFIGURATION SCREEN 6 12 PASSWORD CHANGE SCREEN SC WGWNA B Product Specification Ver 10 Document No ISTZ09025 Decl O00 1 2009 This screen is for change the passwords for login to this Gateway TheAdministrator can access to this screen by the separated secret URL There is no WEB link from any above mentioned screen to this secret screen Authentication Configuration Microsoft Internet Explorer File Edit View Favorites Tools Help AAG REO a v North Overview Monitor Control Commnand Schedule Control System Stop Release South Configuration Menu SUPERLINK WEB GATEWAY Authentication Configuration User Name Adm

Download Pdf Manuals

image

Related Search

Related Contents

User`s Manual PC Classic PC Classic Plus  S.I.C. 極魂 Vol.20 仮面ライダーカイザ 取扱説明書 193.7 KB  www.frontalie rslorraine .e u  Panasonic MC-V5485 Vacuum Cleaner User Manual  Minute Man Endeavor  Atlantis 5 User manual  OpenLAB Data Analysis di Agilent  2 volets centres loisirs VEZENOBRES sept 2013.indd  取扱説明書 - お客様サポート  Pioneer X1 Operation Manual  