Home
        here - All-Battery.com
         Contents
1.        This specification is the enterprise standard of Li Cell  without authorization  any pirate or circulation is prohibited    4       The Leader in Total Power Solution    TENERGY                                                          voltage  No  7 8  Discharge Discharge current Discharge Degree leakage   20  C 0  C 25  C 60  C Ka  Character 2 4A appearance   gt 60   gt 80  100   gt 100  defect  efec  8  Safety Characteristics  single cell   Items Test Condition Criteria  A 15 8 mm diameter bar is inlayed into the bottom of a 9 1kg weight    No explosion   8 1  Impact And the weight is to be dropped from a height of 610mm onto a No fire  sample cell and then the bar will be across the center of the sample   8 2  Short To short circuit the Cell charged 3 65 V by connecting positive and No explosion   Circuit negative terminal by 50milli ohm wire for 1 hour  No fire  8 3  Over Cells are charge at constant current of 3CsmA and constant voltage of   No explosion   Charge 5V for 2 hour  No fire  8 4  Over After standard charge  Cells are discharged at constant Current of No explosion   discharge 0 2CsmA to 2 0V  and the positive and negative terminal is connected   No fire  by a 30 wire for 24 hour   8 5  Nail test A Steel needle  diameter  2 5mm 5mm  is Penetrated vertically No explosion   through the center of a fully charged cell No fire  8 6  Heating After standard charge  Cells are heated in a circulating air Oven ata   No explosion   test rate of 5  C per minute to 1
2.    i E ERGY The Leader in Total Power Solution    SPECIFICATION OF PRODUCT    For Lithium ion Rechargeable Battery  Model  IFR18650E 1500 4S8P 12 8V 12Ah with PCM                                              Prepared by Checked by Approved by  Signature Date  are Company name   Approval  Company Stamp   Dec   2011    This specification is the enterprise standard of Li Cell  without authorization  any pirate or circulation is prohibited       i E ERGY The Leader in Total Power Solution    History of revision       Version Description Date    A 0 First issue 2011 12 06                                     This specification is the enterprise standard of Li Cell  without authorization  any pirate or circulation is prohibited    2       i E ERGY The Leader in Total Power Solution    1  Scope  This Product Specification describes the requirements for the rechargeable lithium ion battery    Battery   to be supplied by Tenergy Corporation    2  Description and Model       2 1  Description Lithium ion rechargeable battery       2 2  Model IFR18650E 1500 4S8P 12 8V 12Ah With PCM             Note  IFR 18 650 E 1500 4S8P   LiFePO4  Li ion Cylindrical Diameter Height  Kind   Capacity  Configuration Code       3  Nominal Specifications                Items Specification  3 1  Nominal Capacity 12 5Ah  Typ   12 0Ah  Min    3 2  Nominal Voltage 12 8V  3 3  Charging Voltage 14 60  0 05 V  CC CV  3 4  Charging method Constant Current with limited Voltage  Constant    Voltage with limited Curren
3. 50  C and keeping the state for 30 minutes   No fire  8 7  Crush Crush between two flat plates  Applied force is about 13kKN 1 72Mpa    No explosion   for 30min No fire                         9  Protection  When Li ion rechargeable battery is used over the permitted voltage or current   electrolyte may disassemble  and this case will affect safety performance of Li ion rechargeable                                                 battery   10  Specifications of PCM   No  Test item Criterion  1 Voltage Charging voltage DC 14 6V  2 Ciureni Low current consumption for single cell  lt 20uA  Maximal continuous discharging current 30A  Over charge Protection Over charge detection voltage 3 90 0 025V  3  single cell  Over charge detection delay time 1 040 5S  Over charge release voltage 3 80 0 05V  o   Over discharge detection voltage 2 00 0 08V  ver discharge        4 protection  single cell  Over discharge detection delay time 144mS 50mS  Over discharge release voltage 2 30 0 1V  Over current detection voltage 0 15 0 025V  5 Over current protection Over current detection current 8045A  Detection delay time 12ms             This specification is the enterprise standard of Li Cell  without authorization  any pirate or circulation is prohibited    5       i E ERGY The Leader in Total Power Solution                               Release condition Automatic Recovery  Detection condition Exterior short circuit  6 Short protection Detection delay time 200 500us  Release condition Automat
4. es  or batteries of a different  package  type  or brand     Stop charging the battery if charging is not completed within the specified time     Stop using the battery if abnormal heat  odor  discoloration  deformation or abnormal  condition is detected    During use  Charge  Storage     Keep away from fire immediately when leakage or foul odor is detected     Tf liquid leaks onto your skin or clothes  wash well with fresh water immediately   If liquid leaking from the battery gets into your eyes  do not rub your eyes  Wash them well  with clean water and go to see a doctor immediately       Caution     Store batteries out of reach of children so that they are not accidentally swallowed      If younger children use the battery  their guardians should explain the proper handling      Before using the battery  be sure to read the user   s manual and cautions on handling thoroughly      Thoroughly read the user   s manual for the charger before charging the battery      For information on installing and removing from equipment  thoroughly read the user   s manual  for the specific equipment      Batteries have life cycles  If the time that the battery powers equipment becomes much shorter  than usual  the battery life is at an end  Replace the battery with a new same one      Remove a battery whose life cycle has expired from equipment immediately      When the battery is thrown away  be sure it is non conducting by applying vinyl tape to the      and     terminals      When no
5. ic Recovery  7 Resistance Protection circuitry  MOSFET   lt 60mQ  Balance Start Point voltage 3 60 0 025V    Rep nce Balance Current 100 10mA  9 Tennan Operating Temperature Range  10  65 L  Storage Temperature Range  40  85  C                11  Product Liability    The Safety should be sure to confer previously with between the both parties    The results of the conference must be recorded and the range of the liability or the burden should  be cleared    The indications of a warning are established by conference with between the both parties     12  Shipping    The capacity of delivery battery is approximately at 50  of charging  During transportation  keep  the battery from acutely vibration  impacting  solarization  drenching     13  Warranty    As long as the Battery is treated in accordance with this Product Specification and   or Handling  Precautions and Prohibitions  Supplier warrants that the Battery should be free from any defect for  a period of 6 month  25  C or less  from the date of shipment or for 1000 cycles  see 7 3    whichever comes earlier    The warranty set forth above or described in Handling Precautions and Prohibitions for Lithium  Ion Rechargeable Batteries excludes a defect  which is not related to manufacturing of the Battery     14  Others    14 1 Storage for a long time If Battery is preserved for a long time  more than 3 months   the  Battery should be preserved at the dry and low temperature    14 2 Other Any matters that this specification d
6. oes not cover should be conferred between the  both parties       Note    When charging the battery  use dedicated chargers and follow the specified conditions     Use the battery only in the specified equipment     Do not connect battery directly to an electric outlet or cigarette lighter charger     Do not heat or throw battery into a fire     Do not use  leave battery close to fire or inside of a car where temperature may be above  60  C  Also do not charge   discharge in such conditions     Do not immerse  throw  and wet battery in water  seawater     Do not put batteries in your pockets or a bag together with metal objects such as necklaces     This specification is the enterprise standard of Li Cell  without authorization  any pirate or circulation is prohibited    6          i E ERGY The Leader in Total Power Solution    Hairpins  coins  or screws  Do not store batteries with such objects     Do not short circuit the     and     terminals with other metals     Do not place battery in a device with the     and     in the wrong way around     Do not pierce battery with a sharp object such as a needle     Do not hit with a hammer  step on or throw or drop to cause strong shock     Do not disassemble or modify the battery     Do not solder a battery directly     Do not use a battery with serious scar or deformation       Warning    Do not put battery into a microware oven  dryer  or high pressure container     Do not use battery with dry batteries and other primary batteri
7. t                          Can float charging  Cor float charging see 7 1    Standard Charge  2 4A   3 5  Initial Charging Current  Max  Charge   12A  3 6  Max  Discharge Current  Pulse  70 0A  3 7  Discharge Method Standard 2 4A  3 8  Max  Continuous Discharge 30 0 A  3 9  Discharge Cut off Voltage 9 2V      RANET See Fig 1   3 10 Battery Dimension Length Width High  Max    Dimension drawing       OE E 150mm x 100mm x  3 11 Case Dimension Length Width High          95mm  Charge 5  C   60  C  3 12 Operating Temperature 7  Discharge  20  C   60  C  3 13 Storage Temperature 1 month  25  C   45  C                   This specification is the enterprise standard of Li Cell  without authorization  any pirate or circulation is prohibited    3       i E ERGY The Leader in Total Power Solution    3 month  25  C   30  C                3 14 Weight 1 4 0 1Kg       4  Outline Dimensions  See attached drawing  Fig  1      5  Appearances  There shall be no such defect as scratch  flaw  crack  rust  discoloration  leakage  which may  adversely affect commercial value of the battery     6  Reference Standard and Test Conditions    This specification is compiled by referring the Standard UL1642  IEC61960 2003  UN38 3  GB T 18287 2000 and so on   Unless otherwise specified  all tests stated in this Product Specification are conducted at  temperature 25 45  C and humidity 65420  RH  If it is judged that the test results are not  affected by such conditions  the tests may be conducted at temperat
8. t using battery for an extended period  remove it from the equipment and store in a place  with low humidity and low temperature      While the battery pack is charged  used and stored  keep it away from objects or materials with  static electric charges      If the terminals of the battery become dirty  wipe with a dry clothe before using the battery      The battery can be used within the following temperature ranges  Do not exceed these ranges   Charge temperature range  5  C to 60  C  Discharge temperature range   20  C to 60  C   When using equipment     This specification is the enterprise standard of Li Cell  without authorization  any pirate or circulation is prohibited    7       y E ERG Y The Leader in Total Power Solution    Fig 1 Dimension drawing IFR18650E 1500 4S8P 12 8V 12Ah with PCM  Case dimension  1mm   L151mm W98mm H95mm  excluding terminal     146  3mm  I S fo T   ONAIN F   Xe i Sf i NZ E i  LOI OKKXXAAXXXXXNO   O                                   PIV ZSZ IOI          J Low J J  OLA      fe IN x   TA Se      X y i        N   hy i  N   JN DX AN i    LIO F y   i    ew  N S4 J v i  x K N Z  SO   PV  lt  S      Ne    a  1   7 fo     ox                                       I  Z    ae    H   lar    CO                                     This specification is the enterprise standard of Li Cell  without authorization  any pirate or circulation is prohibited    8    
9. ure 15   30  Cand humidity  25  85 RH    7  Electrical Characteristics       Items Test Condition Criteria       The  Standard Charge  means charging the Battery with initial charge current  2 4A and with constant voltage 14 60 V  then constant voltage   14 60V  with  floating current taper to 600mA cut off  Charger for exclusive use lithium ion  Charge rechargeable battery  with an accuracy 14 60   0 05V  at 25 5  C  if float  charging  not limit the CV current     7 1 Standard       The capacity means the discharge capacity of the Battery  which is measured  with discharge current 2 4A with 9 2 V cut off at 2545  C within 5 hour after    gt  12Ah  Capacity the Standard Charge    Each cycle is an interval between the charge  charge current 2 4A  CC 2 4A to    7 2  Nominal                                           i 14 60V  CV to 600mA   stop 30min and discharge  discharge current 1 3A  Pi    7 3 Cycle Life   with 9 2V cutoff  stop 30min at 25 5  C Capacity after 1000 cycles and plus 1 S  ae i capacity  day  measured under the same conditions stated in 7 2   7 4  Internal    Internal resistance measured at 1KHz after Standard Charge   lt 300m2Q  Impedance  75 Rated   Charge Current Discharge Current  2 4A 6 0A 12A 24A  capacity 2 4A  100  295  290   gt 85   76 Charge Capacity after 28 days storage at 25  C from Standard Charge  measured under   Retention    P the same conditions stated in 7 2  capacity  retention  gt 85   As of shipment 12 80   7 7  Battery 13 60  V          
    