Home

CH_CP Extractors Manual

image

Contents

1. When the extractor is to be installed above a gas hob the minimum distance between the hob and extractor must exceed 700mm 750mm is recommended If the instructions provided with your gas hob state that the required distance between the hob and extractor must be greater than 700mm then that is the distance that should be observed this is a legal requirement and may lead to your hob being disconnected from the gas supply and the installation being reported to RIDDOR The height should be measured from the top of the burners IN THE ABSENCE OF ANY INSTRUCTIONS SUPPLIED WITH THE GAS HOB THE MINIMUM DISTANCE BETWEEN THE HOB AND EXTRACTOR MUST BE AT LEAST 760mm Gas 750mm recommended Electric 650mm recommended The width of any hob must not be greater than the width of the extractor installed above it Fig 3 Ducting and Ventilation For best performance and lowest noise output we recommend the use of 125mm ducting You can also use 100mm ducting but this will reduce performance and affect the noise level a4 Height dependent 175 175 200 200 105 The actual height of C depends on the height of the ceiling and the position of the hob INSTALLATION Tools required Mark wall as required see table 2 Drill holes Fit wall fixings and top screws Ensure that any fixings you use are appropriate for the wall type IMPORTANT SAFETY WARNING ONLY USE THE SCREWS PROVIDED WITH THE DUCTING ADAPTOR THE
2. Check that the mains supply has not been switched off 2 Check that the fuse in the spur has not blown GUARANTEE Your new product is guaranteed against defects in materials and or workmanship A be repaired or replaced at our discretion All repairs must be carried out by an autho comes with a 1 year parts and labour guarantee THIS GUARANTEE IS VALID PROVIDING THAT THIS GUARANTEE DOES NOT COVER e The appliance has been installed by a suitably qualified person e Damage by misuse neglect or transit e Use of parts that have not been e Installation has been carried out in recommended accordance with instructions and current legislation e Routine maintenance general wear amp tear and installation faults e Proof of purchase can be produced e Rubber seals removable glass and or plastic parts fuses or light bulbs which all need replacing periodically e The appliance has been used for domestic purposes only e Second hand or reconditioned appliances e The appliance has not been tampered with or repair attempted or modified by any unauthorised person Appliances used for commercial or professional purposes This guarantee does not in any way affect your statutory legal rights Mounting your Extractor When the extractor is to be installed above an electric hob the o 2 2 2 mee a minimum distance between the hob and extractor must exceed 600mm 650mm is recommended
3. USE OF LONGER SCREWS MAY CAUSE DAMAG WHICH WILL NOT BE COVERED BY THE WARRANTY The metal casing of this appliance has been coated with a preservative to protec This should be removed during installation by using a non abrasive stainless ste instructions given with the cleaner being used SIA Please call for Service contact number 01623 752919
4. the following code Green amp Yellow Earth Blue Neutral Brown Live USE A 3 AMP FUSE As the colours of the wires in the mains lead for the appliance may not correspond with the coloured markings identifying the terminals connecting to the fuse spur proceed as follows e The wire which is coloured green and yellow must be connected to the terminal marked E Earth or coloured green e The wire which is coloured blue must be connected to the terminal marked N Neutral or coloured black The wire which is coloured brown must be connected to the terminal marked L Live or coloured red Note Use a 3A Fuse Assembly and electrical connection should be carried out by specialised personnel When installing this product we recommend you seek the help of another individual Do not mount the isolation switch behind the chimney section It is a requirement that you must be able to isolate the extractor from the mains electrical supply after installation This appliance is intended to be connected to the mains electrical supply by means of an isolation switch and fused spur and is intended to be protected by a 3A fuse The use of a 13A fuse can cause damage to the internal wiring in the event of a fault and may also invalidate the warranty Electrical Information Mains electrical voltage 230 240Vac 50Hz Total rated power consumption CH amp CP 176W Troubleshooting If your extractor is not working 1
5. i SIA CH61 71 91 101 CP61 71 91 101 Extractors Manual for Installation Use and Maintenance Important The manufacturer cannot be held responsible for injuries or losses caused by incorr Please note that the manufacturer reserves the right to invalidate the guarantee sup incorrect installation or misuse of the appliance or use in a commercial environment This appliance is not designed to be used by people including children with reduc capacity or who lack experience or knowledge about it unless they have had super the appliance by someone who is responsible for their safety Under no circumstances should any external covers be removed for servicing or ma qualified personnel Appliance information Please enter the details on the appliance rating plate below for reference to assist fault with your appliance and to register your appliance for guarantee purposes Appliance Model o O seriatnumber CE Declarations of Conformity This appliance has been manufactured to the strictest standards and complies with Gas safety Electrical safety LVD and Electromagnetic interference compatibility EM IMPORTANT INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN Ai 2002 96 EC At the end of its working life the product must be taken to a special local authority dealer providing appliance recycling services Disposing of a household appliance consequences for the environment and health It also enables the constituent mate
6. ntenance IMPORTANT DO NOT PERFORM MAINTENANCE OR CLEANING OF THE EXTRACTOR WITHOUT FIRST SWITCHING OFF THE ELECTRICITY SUPPLY Cleaning You should use a nonabrasive cleaner Any abrasive cleaner including Cif will scratch the surface and could erase the control panel markings You can clean your extractor effectively by simply using a dilute solution of water and mild detergent and drying to a shine with a clean cloth Cleaning the grease filter The grease filter should be kept clean to minimise the risk of fire At least once a month you should remove and clean the grease filter with hot soapy water You can also wash the grease filter in a dishwasher ensuring that you place it in an upright position to prevent damage from other items in the dishwasher After rinsing and drying replace the filter To remove the grease filter push in the button on the handle and then pull down on the filter at the front When you have released it at the front then you can pull out the filter To replace the grease filter repeat the steps in reverse Please note Cleaning the grease filter in the dishwasher may lead to discolouration This is normal and does not constitute a fault with the appliance Changing the charcoal filter re circulating only To ensure best performance of your extractor you should replace the charcoal filter every four to six months depending on use To attach a new charcoal filter first remove the grease fil
7. ri energy and resources As a reminder of the need to dispose of household appliances separately the prod wheeled dustbin X Please note Under no circumstances should the extractor be connected to any gas ventilatio ducting system gt Donotvent the extractor into an attic or loft space e Only house the extractor in rooms with adequate ventilation Remember that the air is extracted needs to be replaced e Do not tile the extractor in It should be removable for service or maintenance Do not use silicone sealant to secure the hood to the wall You must be able to isolate the extractor from the mains electrical supply after in Steam cleaners must not be used when cleaning this appliance The performance of your extractor will vary depending on a number of factors T length of ducting room volume ventilation available and cleanliness of the filters Using your Extractor For best performance you should switch on the extractor 15 minutes before starting for approximately 15 minutes after the end of cooking Control Panel A Power off button B Speed level buttons C Light button Controls To switch the extractor light on or off e Press button C To switch on the extractor or change the motor speed at any time when the extrz e Press the relevant speed button B for the first second or third speed as require To switch the extractor off e Press button A Care and Mai
8. ters as described above Insert the charcoal filter into the guide on the side of the motor then slide the filter in until it locks into place Repeat with the second filter on the opposite side Finally replace the grease filters Changing the Light DO NOT CHANGE THE LIGHT BULB IMMEDIATELY AFTER USE AS THE BULB W BEFORE REMOVING IT Remove the grease filters Unscrew the light bulb and replace with the required ligh Finally replace the grease filters Do not touch bulbs or adjacent areas during or straight after prolonged use of the li The light is designed for use during cooking and not for general room illumination the life span of the bulb Bulb replacement is not covered by the guarantee Only use bulbs recommended for your extractor Do not fit bulbs of a higher power r Bulbs of a lower power rating may be adequate for use generally last longer and us 28W max candle bulb E14 SES Table 1 Mains Electricity Connection THIS APPLIANCE MUST BE CONNECTED TO THE MAINS SUPPLY BY A COMPETENT PERSON USING FIXED WIRING VIA A DOUBLE POLE DOUBLE POLE SWITCHED SWITCHED FUSE SPUR OUTLET AND PROTECTED BY A 3A FUSE FUSE SPUR OUTLET Warning This appliance must be earthed We recommend that the appliance is connected by a qualified electrician who is a member of the N I C E I C and who will comply with the I E T and local regulations The wires in the mains lead of this appliance are coloured in accordance with

Download Pdf Manuals

image

Related Search

Related Contents

  the YouBrew® Glass  Quick Installation Guide  Simpli Home 3AXCBED-01 Instructions / Assembly  藤沢市倫理法人会 経営者モーニングセミナーのご案内  Télécharger  木材製品予防的管理イ足進 軍業報告書  Xerox Phaser 6600 User's Manual  PDFカタログ 1022KB  Monnit Wireless Control User's Guide  

Copyright © All rights reserved.
Failed to retrieve file