Home

LCS-US204 UM - longshine networking

image

Contents

1. 15 0 E E E AAA 15 4 4 Installation of USB Device Drivers eee 16 4 5 Using the USB Device Server iic iain 18 4 6 Auto Connect TTUMET 20 4 7 Network Scanner e 23 4 8 USB eae pcds 25 4 9 Re guestto C nnect oen te phu Ua 26 4 10 Quitting the Control ale se EO ei etse e ui eode 27 QUE 27 CHAPTERS JFILESERVER tes 28 MEME S Mi ux PTT Gaia ean Need 28 5 2 Connecting USB Mass Storage to the Server 28 Du ASHDDOPICU A ONC DIES a Ex Leda 28 5 4 Using Shared Storages by SMB CIFS Method for Windows 30 DID Using Shared Storage by FTP Methods for 0 sess 31 CHAPTER6 THE SERVER S WEB PAGES 33 61 steer ait iri da 33 6 2 Using the Server Web Pages vu es aei estratti 33 0 2 1 Displaying Server SIatisuici denda eer pb ee 33 6 2 2 Setting up Server 608 34 CHAPTER7 D 1 L8 B 38 7A EBD MdicatOrS est s EE E 38 AREE oo c eee 38 CHAPTERS RESTORE FACTORY DEFAULTS estin eohesoa ee eoe tss one een po Sore eere PM eee op Ce eg asap
2. General Wireless a Administrator Maintenance Factory Default Download New Firmware Firmware Upgrade 36 USB Device Server Logout 3 HOME STATUS CONFIG Maintenance Wireless Y Administrator ul General Y 37 Upgrade Firmware New Firmware File Chapter7 Troubleshooting This chapter provides useful information to help you resolve difficulties that you may experience with your Server Fault symptoms possible causes and remedial actions are provided within a quick reference table This Server s USB ports only support MFPs printers scanners mass storage and USB cameras 7 1 LED Indicators Indicators Behavior Description Power On Power On Off Power off System error Link On Network connected Off No physical connection to network Status Blinking Activity on network Off No activity on network USB On USB device connected Blinking Connected USB device error Off No physical connection to USB device 7 2 Firewall If a firewall software has been installed on your PC it may block the communication between the PC and the USB device server so that the USB device server can not work properly To solve this problem either disable the firewall or configure the firewall to allow the following TCP and UDP ports 7303 7305 20005 30201 30202 30203 38 Chapter8 Restore Factory Defaults You may restore the Server
3. 3 Click CONFIG icon 4 Login the Server with Administrator default admin and Password default admin 5 Click Maintenance 6 Click Upgrade Firmware tls LONGSHINE USB Device Server HOME STATUS CONFIG Logout General Wireless Administrator Maintenance Upgrade Firmware New Firmware File Upload 7 Click Browse button to choose the file of new firmware 8 Click Upload button to start firmware upgrade 9 Wait for 20 seconds for system reboot 41 Chapter10 The Init Button The Init button is used for maintenance Simultaneously press Init button and turn on by plugging in the power adaptor the Server until USB1 and USB2 LED indicators simultaneously blinks After that the Server will do the following tasks A Perform a Factory Default restoration of the server which will restore most of the parameters and settings to factory default values B Perform a TFTP server You can upgrade new firmware using any TFTP client tool Note After performing the tasks mentioned above you have to plug off the power adaptor and then plug in the power adaptor to restart the Server 42 Chapter11 FCC Statement Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential instal
4. s default parameters by one of the following methods 8 1 Using the Server s Web Pages 1 Go to the Server s web page and click CONFIG 2 Enter administrator default admin and password default admin 3 Click Maintenance 4 Click Factory Default tls LONGSHINE USB Device Server HOME STATUS CONFIG General Wireless Administrator Maintenance Load the Factory Default This server will load the factory default and then restart 5 Click Yes to confirm 8 2 Using Init Button Plug in the power adaptor while pressing the Init button until LED indicators of USB1 and USB2 blink After that plug off the power adaptor and then plug in the power adapter again to restart the Server Finally the Server will operate using the Factory Default values 8 3 Default Parameters List General Information Server Name LCS US204 TCP IP Automatically get IP by DHCP Enabled 39 40 Static IP Disabled IP Address 192 168 1 100 Subnet Mask 255 255 255 0 User Accounts Administrator admin Password admin Chapter9 Upgrade Firmware This chapter describes how to upgrade firmware Please follow one of the following Procedures Procedure A Using the Control Center 1 Open Control Center It will automatically search the existing Servers and display their statuses 2 Select the Server that you want to upgrade the firmware Double click the selected Server to get the serve s main web page
5. Link indicator lights up the Server is correctly connected to the network When USB1 and USB2 indicators stop flashing the Server starts to work normally Wireless connection Preliminary Before you can access wireless network wireless parameters should be set correctly You have to setup the first wireless parameter set through LAN wired connection Wireless access can be set as infrastructure station mode which needs an access point to route network messages with the same SSID Wireless access can be secured by WEP 64 128 WPA PSA TKIP AES and WPA2 PSK AES In infrastructure mode if network administrator wants to change any security related parameters LCS US204 should be changed first and then access point If parameters mismatch causes wireless access is not allowed you have to modify those parameters through LAN connection In infrastructure mode the maximal transfer rate is 54 MBits depending on access point s capability Set Wireless Configuration Using Control Center Install USB Device Server Control Center It is available in the LCS US204 USB Device Server Product CD Start USB Device Server Control Center and Auto searching USB device server window will appear fag Longshine LCS USB Device Server gt LCS USB Device Server gj Uninstall If the wireless parameters are not correct or not set yet you have to use LAN to access 7 3 1 3 2 3 2 1 3 2 2 USB Device Server Control C
6. iE LCS USB Device Server Control Center TER System Tools About oy Vv E Ze I Configure Auto Connect Connan i juest t Network Printer Gusto Corine Scanner gt 05415204 163 254 217 15 Mass Storage SanDisk Corporation Cruzer Contour MFF EPSON EPSON Epson ME 320 Series IE Auto Connect Printer List Server IP amp Printer Name Windows Printer Name 169 254 217 16 EPSON EPSON Epson ME 320 Series EPSON ME 320 Series F Then try to issue a print job to the desired printer You will see the Control Center will automatically do a connect operation Then the print job will be issued to that printer G Even you already properly setup an auto connected printer the Control Center must be running in the background while a print job is issued This means you d better run the Control Center every time after you login Windows In order to skip this manual operation you can make the Control Center be run automatically after you login Windows To do this choose the Configuration item in the Tools menu The following window will appear Click on the check box and then on the OK button This feature is enabled by default 22 IE Control Center Configuration Basic Automatically execute when logging on Windows Lanquage Ehh Deutsch Note Language setting will take effect on next execution j Cancel If you would like to break the association between the Win
7. noun 39 8 1 Using the Server s Web Pages ter bro pn Osc ate Fo eaa 39 Gu Using Ini uon de ce TE dmn du dia 39 8 3 Default Parameters Listos iriiria END uude dat UM NR 39 CHAPTER9 UPGRADE FIRMWARE 41 THE INIT 42 FCC STATEMENT ssava lar Ro ENS QURE EAS CE XE ERR 40 Chapter1 Introduction Thank you for purchasing LCS US204 USB Device Server in the following referred to as Server This Server is designed to connect your Multifunction Printer Scanner Fax Multifunction Printer Hard Drive iPhone iPod USB Digital TV Tuner Digital Camera USB Webcam USB Speaker USB CD USB DVD to your network allowing all network users access to these shared USB devices 1 1 3 About Server Described in this Manual This manual provides introductory information as well as detailed instructions on how to set up and manage LCS US204 in various network environments LCS US204 has a 10 100 Mbit sec Lan port wireless module 802 11b g and four USB ports To fully benefit from this document you should be familiar with basic networking principles The instructions described in this manual are based on the settings in a new Server To reload the Factory Parameters you can reset this Server back to Factory Default which will restore most of the settings For details please refer to the chapter Restore Factory Def
8. pages Click CONFIG icon tls LONCSHIBE USB Device Server HOME STATUS CONFIG Welcome Click STATUS to show your system status Click CONFIG to adjust each setting of the device Visit our website at www longshine de for more information 5 Login with administrator ID default admin and its password default admin 13 ts LONGSHINE USB Device Server HOME STATUS CONFIG Logout General Wireless Administrator Server LCS US204 15 letters max Workgroup WORKGROUP 15 letters max Description optional US204 USB Device Server 48 letters max Storage Access Mode Ail Serer Mode 9 NetUSB Mode Automatically get IP by DHCP O Static IP IP Address 192 168 1 100 15 letters max E Subnet Mask 255 255 255 0 15 letters max 6 Click the button corresponding to your choice of IP setting methods static or dynamic using DHCP When assigning a static IP address you also have to define Subnet Mask 7 Click Submit to save your settings And the Server will reboot You have now finished the procedure of setting the IP address 14 Chapter4 Using the USB Device Server 4 1 Introduction The goal of this produce is to provide the USB device server in a single product We developed a new technology called NetUSB to achieve this goal Basically the NetUSB is a USB over IP technology that transparently redirects
9. s Server Name or open server s IP address If you have changed the default FTP port 21 to the new value you have to add the new port number in the tail of command as open server s Server Name ftp port or open server s IP address ftp port 3 If you set Enable Server Authentication in FTP server protocol settings you have to enter user name and password to login to the Server if you set Allow Anonymous Login you can use the user name anonymous to login with Read only permission If you clear Server authentication you do not need username or password to login to the Server You can add user name and password in User Account box the Control Center or the Server s Web pages 3l 32 Perform FTP commands to use this FTP server 4 Chapter6 The Server s Web Pages 6 1 Introduction The Server runs the http server httpd on TCP port 80 Users may use the web pages to see the Server s system status and configure the Server 6 2 Using the Server s Web Pages 6 2 1 Displaying Server Status Click on the STATUS icon to see system status network status and Wireless Status tls LONCSHINE USB Device Server HOME STATUS CONFIG System Status Network Status Wireless Status Firmware Version 1 026 Model Name LCS US204 MAC Address 2 tls LONCSHINE USB Device Server HOME STATUS CONFIG Logout System Status 8 Status Wireless Status Server Name LCS US204 Storage Access Mode NetUSB
10. there are two computers TESTES and TEST Now the owner of HP Photosmart 2600 is TEST Then the TESTES computer wants to use this HP printer The user on the TESTES computer can click the Request to Connect button in the Control Center The following window appears 26 i LCS USB Device Server Control Center TBR Ill Request to connect device Remote User TESTES Server 192 168 1 100 Device Photosmart 2600 Series we Cancel At this moment the user on the TEST computer will see the following window indicating that another computer TESTES is requesting to use the HP printer i LCS USB Device Server Control Center TBR 6 Ill Remote User request to connect device Remote User TEST 192 168 1 101 Server MFP 192 168 1 100 Device MFP HP Photosmart 2600 Series Note Click Accept will disconnect the device right now The user will choose to accept or reject If accepted the Control Center on TEST will automatically disconnect the device and the Control Center on TESTES will automatically connect that device 4 10 Quitting the Control Center The Control Center doesn t really quit if you click the X box close box at the top right corner of the window Instead it just minimizes itself to the system tray There are two ways to really close the Control Center The first way is choosing Exit item in the File menu in the Control Center
11. D Now PC will detect the plug in of the USB device The connect operation is a software operation that simulates an actual USB device plug in That is to say when you do a connect operation in the Control Center PC can then detect a USB device s plug in although actually you do not plug in any USB device E Then just use the USB device as if it is connected directly to your PC s USB port F After you finish using the USB device click the USB device in the Control Center and then click the Disconnect button to disconnect the USB device Other PCs can not Connect the USB device until you Disconnect that USB device That is to say only one PC is allowed to connect the USB device at the same time 19 i LCS USB Device Server Control Center TER System Tools About A la anfigure Disconnect e LC5 L15204 56 Mass Storage SanDisk Corporation Cruzer Contour Manually Connected by JOAN 1 4 6 Auto Connect Printer The method described in section 4 5 is so called manual connect which means users must manually connect the USB device before using that device and must manually disconnect the USB device after using the device otherwise nobody else can connect this device However for printers and scanners and MFPs the USB device server supports auto connect so users don t need to manually connect disconnect This and the next sections show you how to do this After the dri
12. LCS US204 USB 2 0 Hi Speed Port Device Server User s Manual Version 1 0 Table of Contents INTRODUCTION Mee SE PER P Ep RUE 1 1 About 4 Models Described in this Manual eene 4 1 2 sa dicti aa tus bea abo uud br dud 4 CHAPTER2 PRODUCT OVERVIEW Zu Package Contents Aah uc a slides ed ee D 2 2 Product CD A DS 5 2 2 1 Start up Procedure oce la 2 21 3 5 24 Supported USBIEVICES d Nae cei e opta iios 5 CHAPTER3 BASIC INSTALLATION etae oece Ne ky b paso KS 3 1 Connecting the 7 0 7 7 3 2 2 Set Wireless Configuration Using Control 171 7 3 3 Assigning an IP Address to the ncaa 11 Sub 11 E ME Ly i RM ER 12 3 3 3 Methods for Setting the IP Address estis ete lorena 12 3 3 4 Server Names and Server Name Rules 0 12 3 3 5 Setting the IP Address Using DECP o E 12 3 3 6 Setting the IP Address Using the Control Center eese 12 CHAPTER4 USING THE USB DEVICE SERVER ccccccsscsssssssscssscscsssessssecsssescsesscessscsssess 15 Introduction 15 4 2 Connect amp
13. LCS US204 15 letters max Workgroup WORKGROUP 15 letters max Description optional US204 USB Device Server 48 letters max Storage Access Mode Server Mode O NetUSB Mode TCP IP Automatically get IP by DHCP O Static IP IP Address 192 168 1 100 15 letters max Subnet Mask 255 255 255 0 15 letters max UPnP 9 Enable O Disable 5 4 Using Shared Storages by SMB CIFS Method for Windows 1 Connect a USB storage device to this product 2 Select My Network Places 3 Click Display the Computers of Workgroup 4 Double click Microsoft Windows Network icon 5 Double click the Workgroup that the Server belongs to The default Workgroup name is WORKGROUP You can refer to Control Center or the Server s web pages to get it You will see that the Server is displayed as its server name 6 If you cannot find Workgroup name of the Server in Microsoft Windows Network you can select Search for Computer in My Network Places and enter the Server Name of the Server to find it 7 Double click this Server Name icon 8 If you clear Enable SMB CIFS Print File Server Authentication in Supported Protocols you login to the SMB server without requiring authentication otherwise you have to enter user name and password to login 30 to the Server You can add user name and password in User Account box by the Control Center or the Server s Web page Note If you u
14. Mode IP Address 169 254 217 16 dhcp failed Subnet Mask 255 255 0 0 DHCP Server 0 0 0 0 Lease Time second 33 ts LONGSHINE USB Device Server HOME STATUS CONFIG Logout System Status Network Status Station Name SSID BSSID Channel No Network Type Link Quality Signal Strength Security System 6 2 2 Setting up Server Configuration To set up the Server configuration click on the CONFIG icon ad then the system will request user to enter administrator default admin and password default admin to login m General Configuration gt Server Information You have to set the Server Name which is the name to represent the Server 34 dh LONGSHINE USB Device Server HOME STATUS CONFIG Logout Wireless Administrator Maintenance Server Information Server Name LCS US204 15 letters max Workgroup WORKGROUP 15 letters max Description optional 105204 USB Device Server 48 letters max Storage Access Mode Server Mode O Mode Automatically get IP by DHCP O Static IP IP Address 1192 168 1 100 15 letters max Subnet Mask 255 255 255 0 15 letters max UPnP Setting UPnP 9 Enable Disable TCP IP You have to set the Server s TCP IP configuration to connect TCP IP network Please see Chapter 3 Basic Installation for more details Storage Access Mode Set storage access mode as server or NetUSB mod
15. NE USB Device Server HOME STATUS CONFIG Logout amp General 00091888 Administrator Y Maintenance Basic Station Name 00 1 2 Network Type SSID 32 letters max Security System WEP WEP Settings Authentication Key Size 64 Bit Hex 10 chars Q rr id ABCDEFA LU icd ee Key 4 100 9 If the wireless network is secured by WPA PSK or WPA2 PSK the key formats shared key and encryption must be set correctly 10 tls LONGSHINE USB Device Server HOME STATUS CONFIG Logout General 08888 Administrator Maintenance Basic Station Name 00 1 1 E5 88 26 02 Network Type Infrastructure 5910 Longshine 32 letters max Security Security System WPA PSK WPA PSK Settings Key Format Passphrase 8 63 chars Pre Shared Key ABCDEF4321 Encryption Note VV PA PSKAVPA2 PSK is not available with ad hoc networks Site Survey Setting WPS Setting WPS Enable ODisable 10 Click Submit to save your settings And the server will reboot 11 You have now finished the procedure of setting the wireless parameters After properly configuring the wireless parameters you can remove the network cable and reboot LCS US204 LCS US204 will then connect to your wireless network LCS US204 will detect if a network cable is plugged in or not If a network cable is plugged in LCS US204 will always connect to the network through the network cable Otherwise it will
16. RAIS My Pictures Browse Picture Information No 0 Page Location Picture Width Height Dimensions Resolution Bit Depth File Size E Follow the usual steps to do scanning F After the scanning close the Auto Connect Scanner window At this moment Control Center will automatically do a disconnect 4 8 USB Storage You must use manually connect for USB storage After you connect a USB storage like the following picture your PC will have a new disk If the USB storage is a flash drive the new disk is a removable disk 25 LCS USB Device Server Control Center System Tools About m Disconnect e 0515204 56 Mass Storage SanDisk Corporation Cruzer Contour Manually Connected by JOAN Then just use the new disk as a general disk After you finish the disk operations click the storage icon in the system tray and choose Safely remove USB Mass Storage Device to remove the USB storage as the following figure Safely remove USB Mass Storage Device Drive G Then in the Control Center click the USB storage device and click the Disconnect button to disconnect the USB storage device 4 9 Request to Connect If a USB device is manually connected by any other user basically you can not connect that device However we offer another mechanism called Request to Connect to solve this inconvenience For example
17. The second way is right clicking the icon of the Control Center in the system tray and choosing the Exit item 4 11 Limitations There are some limitations to use the NetUSB technology A Only supports Windows 2000 XP 2003 Vista Windows 98 ME is not supported B Only one PC can get the ownership of the same USB device at the same time 27 Chapter5 File Server This chapter describes the file server function of the Server which allows USB storage devices to be shared across a network by using SMB NetBIOS over TCP IP and FTP protocol 5 1 Preliminary 1 This product supports a file format of FAT12 16 32 and NTFS However the write operation on NTFS is only supported in NetUSB mode Please refer to the NetUSB Mode 2 Corporation is not responsible for the loss or corruption of data in memory devices including hard disk Corporation is not responsible for the leak manipulation loss or corruption of data in memory devices connected to the Server after unauthorized access 3 In order to use the USB Mass Storage device connected to the Server the SMB protocol or FTP protocol must be set up 5 2 Connecting USB Mass Storage to the Server LAN HUBISwith The Server Storage m um 5 3 Supported Codepages What is codepage Used by the system to encode and interpret string characters Codepage formats are not the same for each language Some languages such as Japanese have multibyte charac
18. all USB packets to TCP IP network channel NetUSB allows you to use USB devices as if they were connected directly to your PC although they are actually remotely connected to LCS US204 USB device server 4 2 Connect amp Disconnect NetUSB allows you to use USB devices as if they were connected directly to your PC although they are actually remotely connected to the LCS US204 USB device server The connect operation is a software operation that simulates an actual USB device plug in That is to say when you do a connect operation in the Control Center PC can then detect a USB device s plug in although actually you do not plug in any USB device Similarly the disconnect operation is a software operation that simulates the disconnection of the USB device Once the connect operation is successful the operations to use that USB device are just the same as if the USB device is directly connected to the PC If a USB device is connected by a PC we say that PC has the ownership of the USB device Only one PC can get the ownership of a USB device at the same time Therefore if a USB device is connected by one PC no other PC can connect this USB device until this USB device is disconnected 4 3 Subnet Issue Before using the NetUSB technology you must first make sure that your PC can access to USB device server via TCP IP The simplest way to do this is using Control Center to search for the USB device server on the network and c
19. always connect to the network through wireless module Once LCS US204 connects to the network either by network cable or by wireless module all operations to use USB device server are exactly the same 3 3 Assigning an IP Address to the Server 3 3 1 Preliminary m If you have a DHCP server on your network your Server will receive an IP address automatically The IP address will then appear on the Control Center or on the page of configuration report that you printed earlier If your DHCP server does not give an IP address to the Server the Server will use the automatic private IP addressing IP 169 254 0 0 169 254 255 255 m If you are not working in a DHCP network you need to manually set the Server s IP address 3 3 2 IP Address Unless you are assigning an IP address using DHCP you must obtain an unused IP address from your network administrator 3 3 3 Methods for Setting the IP Address You can set the IP address of your Server using one of the following methods depending on your network operating environment m Automatic IP Address Assignment m Manual IP Address Assignment 3 3 4 Server Names and Server Name Rules The default server name of the Server is LCS US204 If you put two or more Servers in your local area network to avoid using the same server names you have to change the server names by using the Control Center or the Server s web pages If your server name is longer than 15 charact
20. aults 1 2 Customer Support Should you require any technical assistance please contact your product reseller Or you can visit our website for latest product information This document is subject to changes without prior notice Chapter2 Product Overview 2 1 Package Contents Verify that nothing is missing from the package by using the checking list below Please contact your dealer if anything is missing or damaged All packing materials are recyclable Please confirm the items in the package below This Server m CD Control Center and User s Manual and Quick Installation Guide Power Adaptor 2 2 Product CD This CD provides easy to use Control Center software and the User s Manual and Quick Installation Guide 2 2 1 Start up Procedures If your computer is configured to auto start CDs this CD will start automatically when inserted You can also navigate to the CD and start the autorun exe file from within the Windows file manager 2 3 Physical Description Power Adaptor Connector for DC IN 12V 1 5A power adaptor Init Button for restoring the parameters to the default values Ethernet Connector connected to a twisted pair category 5 cable Wireless Station IEEE 802 11 b g wireless station with antenna USB Host Ports USB 1 1 2 0 low full and Hi Speed compliant Indicators Power Indicator is lit while power is applied If it is not lit or if it blinks there is a problem with this Server or power adap
21. dows printer and the physical printer just click on the association and click the Delete button in the Auto Connected Printer List 4 7 Network Scanner For NetUSB scanning we recommend you use Network Scanner as the following steps A In the Control Center click the USB device server that has the desired MFP or scanner attached B Click the desired MFP or scanner 23 EEK Network i LCS USB Device Server Control Center System Tools About B 4 Auto Connect 35 Printer Connect 0 Bena p 9204 56 Mass Storage SanDisk Corporation Cruzer Contour lt q EPSON EPSON Epson ME 320 Series C Click the Network Scanner button Then you can see that the Control Center will automatically do a connect operation The following window will appear Cancel IE Welcome to the Auto Connect Scanner lt gt Select a device EPSON NX120 SX125 TX120 ME 320 Crystal Eve Webcam WIA EPSON 461 20 51 26 7241 20 86 32 D Choose one of TWAIN or WIA item Click OK The following window will appear 24 IE Welcome to the Auto Connect Scanner lt gt EPSON NX120 SX125 TX120 ME 320 Image Name and Destination Select name and destination for your pictures 1 Type name for this image set Picture 2 Select a format JPG Image 3 Choose a place to save this image set E V
22. e UPnP Setting Enable or disable the UPnP function File Server Codepage Setup language for file server code L 4 UPnP Setting UPnP O Enable 9 Disable File Server Codepage Lanquage Traditional Chinese 2007 KCodes Corporation All rights reserved Administrator You can change administrator name and password If you forgot administrator name and password you must perform Restore Factory Default action by plugging in the power adaptor while pressing the Init button Please refer to the chapter Restore Factory Defaults 35 Administrator enter your desired administrator name New Password enter your desired password Re type Password re confirm the password 115 LONCSHINE USB Device Server HOME STATUS CONFIG Logout Wireless 7 000 General Set Administrator Administrator admin 15 letters max New Password 15 letters max Re type Password 15 letters max m Maintenance If you want to restore factory default values of the Server or upgrade new firmware you can use the Maintenance tool Restart click this button to restart reboot the Server Factory Default click this button the Server will restore factory default values Firmware Upgrade click Browse to find the firmware file to be upgraded Click Upload to upload the firmware into the Server tls LONGSHINE USB Device Server HOME STATUS CONFIG Logout
23. enter 3 If the tool finds USB device servers in your local area network then you have to select a server from the server list LCS USB Device Server Control Center TER System Tools About 2 gt Configure Auto Connect 5 0 H Equest to N etworl Server Pinter Connect Scanner ww LCS US204 56 X Mass Storage SanDisk Corporation Cruzer Contour 4 Double click the highlighted server or click the Configure Server button to get the server s web pages Click CONFIG icon tls LONGSHINE USB Device Server HOME STATUS lt CONFIG pom Welcome e Click STATUS to show your system status Click CONFIG to adjust each setting of the device Visit our website at www longshine de for more information 5 Login with administrator ID default admin and its password default admin 6 Click Wireless icon tls LONGSHINE USB Device Server HOME STATUS CONFIG Administrator Maintenance Basic Station Name 00 11 5 88 26 02 Network Type SSID 32 letters max Security System Site Survey Setting Scan AP WPS Enable Disable 7 In order to join an existing wireless network you have to set the correct SSID and the correct security method with the correct key information 8 Ifthe wireless network is secured by WEP64 or WEP128 key index and WEP key must be set correctly tls LONGSHI
24. ers the Server uses only the first 15 characters 3 3 5 Setting the IP Address Using DHCP Follow the instructions below to get an IP address using DHCP 1 Edit or create a scope in the DHCP manager of the DHCP daemon The entries included in this scope should contain the following parameters e range of IP addresses e subnet mask e default router IP address DNS server IP address e lease duration 2 Activate the scope The Server automatically gets the DHCP parameters If you are using DNS you may include at least one DNS server IP address in the DHCP scope or manually set the DNS server IP address using Server s web pages or the Control Center 3 3 6 Setting the IP Address Using the Control Center 1 Install the Control Center The Control Center is available on the Product CD 2 Start the Control Center and Auto searching Server window will appear fal Longshine gt LCS USB Device Server gt LCS USB Device Server Uninstall 3 Ifthe tool finds multiple Servers in your local area network then you have to select one Server from the Server List 12 1 LCS USB Device Server Control Center Sum Tooke About a x TA 3 gt Configure Auto Connect m Ia Network Server Printer bonnen Disconnect Seanner lt LCS LIS204 6 Mass Storage SanDisk Corporation Cruzer Contour 4 Double click the highlighted server or click the Configure Server button to get the server s web
25. hange its IP address to be the same subnet as your PC If the server and your PC are not in the same TCP IP subnet Control Center will show the server in red as the following figure You must change the IP address or using DHCP of the server so that the server and your PC are in the same subnet Control Center will show these servers in blue meaning you can access these servers by the NetUSB technology 15 i LCS USB Device Server Control Center 34 System Tools About gt Configure Server e LCS US204 169 254 217 16 Please double click the server to change the IP address 4 4 Installation of USB Device Driver Some USB devices like printers or MFPs multifunction printers require to install vendor supplied driver usually on CDROM For those USB devices that do not need to install driver please skip this section A Insert the CDROM into the CD drive and run the autorun program B Follow the instructions of the installation program to install driver C When the installation program asks you to plug in the USB device run the Control Center D Inthe Control Center click the USB device server that has the desired USB device attached E Click the desired USB device as the following figure 16 i LCS USB Device Server Control Center 3 System Tools About m ou l2 pfe Request tc SH B Connect Ciscorinect ra FEI VE tet Connect Scanner g
26. inimum distance 20cm between the radiator amp your body This transmitter must not be co located or operating in conjunction with any other antenna or transmitter The availability of some specific channels and or operational frequency bands are country dependent and are firmware programmed at the factory to match the intended destination The firmware setting is not accessible by the end user 43
27. lation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help FCC Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation IMPORTANT NOTE FCC Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with m
28. se SMB on Windows 98 SE ME you must login to your Windows 98 SE ME using the same user name as in the Server s User Account 9 The shared folders will be listed as USB1_DyPz and USB2 DyPz where Dy represents the y th disk and Pz represents the z th partition with respect to USB1 port and USB2 port 10 Perform Open Paste Remove or Copy the files to the shared folders 5 5 Using Shared Storage by FTP Methods for Windows A Use Microsoft IE to the shared USB Mass Storages 1 Open Microsoft IE 2 In Web Address List enter command ftp Server s Server Name or ftp Server s IP address If you have changed the default FTP port 21 to the new value you have to add the new port number in the tail of command as ftp Server s Server Name ftp port or ftp Server s IP address ftp port 3 If you set Enable Server Authentication in FTP server protocol settings you have to enter user name and password to login to the Server if you set Allow Anonymous Login you can use the user name anonymous to login with Read only permission If you clear Server authentication you do not need username or password to login to the Server You can add user name and password in User Account box by the Control Center or the Server s Web pages 4 The shared folders will be listed in IE 5 Perform Paste Remove or Copy the files to the shared folders B Use Microsoft Dos s FTP client 1 Enter Dos command ftp 2 Enter open server
29. t LCS US204 169 254 217 16 Mass Storage SanDisk Corporation Cruzer Contour F Click the Connect button Then the message Manually Connect by your computer name will be shown as the following figure i LCS USB Device Server Control Center System Tools About T gt Request to Networks Disconnect Connect Scanner gt LCS US204 56 Mass Storage SanDisk Corporation Cruzer Contour Manually Connected by JOAN G Now the installation program will detect the USB device and continue to install driver H After the installation is completed click the USB device in the Control Center and 17 then click the Disconnect button to disconnect the USB device Now the driver of your USB device is installed 4 5 Using the USB Device Server A Inthe Control Center click the USB device server that has the desired USB device attached B Click the desired USB device iE LCS USB Device Server Control Center TER System Tools About al gt Connect p LCS 15204 56 Mass Storage SanDisk Corporation Cruzer Contour C Click the Connect button Then the message Manually Connect by your computer name will be shown 18 iE LCS USB Device Server Control Center TER System Tools About m Disconnect e LCS 5204 5 Mass Storage SanDisk Corporation Cruzer Contour Manually Connected by JOAN
30. ter LAN Indicator blinks to indicate wired network activity If it is lit it indicates the wired network is applied If it is not lit it indicates that the server does not connect to the wired network WLAN Indicator blinks to indicate wireless network activity If it is lit it indicates the wireless network is applied If it is not lit it indicates that the server does not connect to the wireless network USB Indicator is lit while a USB device connects to a USB Port of this Server If it is not lit or if it blinks there is a problem with the USB device or this Server PU DX 2 4 Supported USB Devices The USB device server supports the following types of USB devices USB Printer USB multifunction printer MFP AIO USB scanner USB storage like USB external HD flash disk and digital camera USB speaker USB camera USB digital TV tuner USB webcam USB CD USB DVD iPod iPhone Chapter3 Basic Installation Connecting the Hardware Make sure that your USB devices are switched off and that the Server s Power Adapter is disconnected Connect the USB devices to the USB ports with the USB cables Connect the Server to the network with a twisted pair category 5 cable 10baseT or 100baseTX Turn on the USB devices and make sure it is ready for use Connect the Power Adapter to the Server The power indicator will light up and USB1 and USB2 indicators will flash in turn When the
31. ters while others such as English and German need only one byte to represent each character Filename Encoding of FAT File System This is known as an 8 3 file name a short file name using codepage encoding The FAT file system also supports file names that can be up to 255 characters long This is known as a long file name using Unicode UTF 16 encoding 28 When do you need to configure codepage The Server supports Windows codepages If users want to communicate files using FTP client tool or SMB on Windows 98 Me 2000 with the Server they have to set their Server codepage to be same as the codepage that their Windows PC is using 1 FTP 2 SMB on Windows 98 Me 2000 Configuring the Server s Codepages Users can use the following methods to set the Server s codepage 1 Start Control Center and Auto searching Server window will appear 2 If the tool finds the Servers in your local area network select the Server from the Server List and click Configure Server button 3 The Web manager will show click the Config button and enter the Server s administrator default admin and password default admin 4 After you have logged in successfully setting General configuration dialog appears 5 Select your codepage form File Server Codepage box and click Apply 29 dh LONGSHINE USB Device Server HOME STATUS CONFIG Logout Wireless Administrator Maintenance Server Information Server Name
32. ver is installed as described in section 4 4 you can see a newly created printer in the Control Panel s Printers and Faxes Follow the steps below to do a NetUSB auto connect printing A In the Control Center click the USB device server that has the desired printer or MFP attached B Click the desired printer or MFP C Click the Auto Connect Printer button and choose Set Auto Connect Printer 20 i LCS USB Device Server Control Center System Tools About Connect EAEE 2 request t Network Scanner Set Auto Connect Printer e LCS US t Mies xornagc Sunes cor poraworr Contour MFP EPSON EPSON Epson 320 Series The following figure will appear IE Add to Auto Connect Printer List gt Installed Printer List lt Printer Name EPSON 320 Series X HP Deskjet F2200 series 6 hp Lasewet 3020 PCL 6 D Choose the desired printer The desired printer must be the Windows printer this is a logical printer that matches the printer attached on the USB device server this is a physical printer Then click the Apply button E Then the printer will be marked as an Auto Connected Printer in red If you choose Auto Connected Printer List in the Tools menu you can see a newly created item that describes the association between the Windows printer and the 21 physical printer on the server