Home

MyTemp™ System - Ductwork Installation

image

Contents

1. Select All Rooms Edit Selected Room s Select No Rooms keyboard to personalize room names as desired Press a room or group of rooms then press the Edit Selected Room s to adjust advanced room parameters You can also press Select All Rooms to adjust the entire house The Select No Rooms button allows you to deselect all highlighted rooms Advanced Room Controls Airflow Normal O Quiet Anticipation Enabled Disabled InRange continued 45 Advanced Room Controls continued Usage Details Airflow The Normal setting allows the system to deliver as much airflow as possible into a room If you set a room to Quiet mode the system opens more ducts to reduce air pressure and thus air noise Note The trade off for Quiet mode is that the system may take longer to bring a given room to temperature In extreme climate conditions the system may not achieve the desired temperature at all In addition you should set as few rooms as absolutely needed to Quiet mode Anticipation Suppose you set the lower limit to 68 F at 7 00 a m By default Anticipation is enabled which means that the system calculates when to start heating in order to ensure the room reaches 68 F by 7 00 a m As the name implies the Anticipation parameter allows the system to anticipate your temperature limits The system may start at different times each day due to outside temperature factors and th
2. System Diagram At the heart of your Home Comfort Zones system lies a sophisticated computer that is housed inside the master unit that is generally mounted near or onto the plenum of your air handler The computer Cold Air program constantly monitors your home and your equipment and intelligently directs conditioning based on the current needs of each room Main Display Touch Screen Pneumatic Damper The master unit is attached to the various components of the system so it can talk to them and coordinate activities You see this when you use the main Air Pump and display touch screen to adjust parameters and Power Supply temperature schedules Your changes are saved in the computer and it adjusts conditioning usage as needed Wireless Smart Receiver a Controllers Air tubes not shown run from the master unit IN Pienam through the ducts to the pneumatic dampers e which deflate and inflate upon command from the ied Ontside computer thus allowing conditioned air to enter Monitor some rooms and not others Each Smart Controller transmits temperature readings to the wireless receiver which sends those readings to the master unit The computer uses these readings along with other information to control which rooms to condition 56 System Diagram Unlike the Smart Controllers the main display does not contain a temperature sensor The inside temperature it displays is that shown on
3. c ceeececceeeeeeeeees 45 Programming Your Comfort Schedules 49 Miscellaneous Features Viewing Your Energy Consumption sirctienciacaceniies 51 Calculating Your Cost Savings icc iesncinnidsicwanchannnss 53 Connected Assistance cccecceecceceeceeeeeeeeeeees 54 System Diagram is Cecnvreencmervoeemerinmneatied 56 Frequently Asked Questions ccc cccecscssersencevecerscese 58 Glosa Y ctidisiwidnsdiididiceadytoncgunbeaiapetbidactanbaned aus 64 Support Phone Numbers iipesvsvussecnianadiiNnnuceoawnnsls 68 System Quick Start Use the graphical table of contents shown below to navigate within this manual The home screen as shown below is the first screen you see after your system is installed From here you can access all the system features Home Away See page 16 Choose between your normal schedule and away schedule Off See page 16 Turn off the system if necessary Time and date See page 30 Press to change either the time or the date Current Activity Sce page 18 Press to view the reason for the current conditioning activity Cf Thu 8 53AM Jul 19 2 Inside Screen Controls Disable Screen for Cleaning _ CA Energy History Outside Standard Zones Ideal Thermostat Thermostat Sce page 19 Use one of three possible thermostat System See page 29 Set parameters that help the modes to set the comfort ranges in system meet your needs your home Tutori
4. 2 Click Next if you would like to include additional information with your request 3 Press the buttons next to your responses and press Next or Submit Now Connected Assistance Page 3 of 4 Please enter your contact information in the spaces below Name Joe amp Jane Customer Phone 555 555 1234 Contact me by telephone Email Contact me by email Connected Assistance Page 4 of 4 After creating your request the system automatically uses your phone line to send the request to customer support Please note that your phone will be unavailable for about five minutes Would you like to delay your call Make the call one hour from now O Make the call tonight after midnight Press the Submit Now button to complete your request Home Comfort Zones will contact you within one business day of receipt 4 If you press Next you can enter your contact information in the next screen The name telephone number and email address is for Home Comfort Zone convenience only they are not mandatory but they will assist HCZ in contacting you for follow up support When done click Next or Submit Now Note When this screen first appears all the text boxes display Edit Click on Edit to access the typewriter screen upon which you can enter your information 5 The last screen allows you to defer the request for a period of time when the modem can use the phone line without causing you inconvenience 55
5. 3 37 _56 0 22 over the last 24 Heat 231 44 0 24 hours Cool Lower limit Upper limit includes the high and low temperatures inside the house plotted against the outside temperature It also displays the amount of circulation heating and cooling that took place in the previous 24 hours 52 Calculating Your Cost Savings On the home screen press Thermostat then Cost Prediction to view the Cost Predictions screen which allows you to enter your basic energy expenditures and select how you want to calculate energy costs When you make changes to temperature schedules the system predicts how much the new settings will cost This prediction is based on a yearly cost and assumptions about your initial energy costs The system includes average weather information built into the predictive model for your climate Pick one of the following options in the Compare Costs to area The fixed settings entered below Compares based on the temperatures you set on this screen In the example above all heating changes are compared to 70 F and all air conditioning changes to 78 F The settings in effect whenever thermostat is pressed Compares current settings to the previous settings This is a dynamic calculation that allows you to see how your current changes impact costs relative to your previous settings The fixed settings in effect now Freezes all settings and compares all future changes relative to you current settings
6. How do I prevent the system from heating ona warm day or in the summer The outside temperature can prevent heating when a room temperature is below its lower limit The heater does not run when the outside temperature is above the Never Heat when Outside Temperature is Above setting page 31 Check this setting if the heater does not run when you want heating From the home screen press the following buttons System gt Furnace and A C Control gt Conditioning with Relation to Outside Temperature Alternatively create a program page 49 For the cooling season you can program the lower limits very low such as 60 F so the room temperatures never call for heating How can I make the system use only circulation when windows are open Create a program page 49 in which all the comfort zones have high upper limits such as 90 F and low lower limits such as 60 F and the Circulation parameter on the Advanced Room Controls screen for each room is set to High page 47 Frequently Asked Questions From the home screen press the following buttons System gt Advanced Room Controls Optionally temporarily change the circulation control parameter to Always Circulate page 34 for the time period the windows are open Afterwards remember to return circulation to the default setting Medium From the home screen press the following buttons System gt Furnace and A C Control gt Temperature Differential and Circulation Cont
7. a Smart Controller chosen by the installer Call the Home Comfort Zones support center if you would like to change the Smart Controller used to represent the inside temperature of your house The outside monitor also contains a temperature sensor that sends readings through the wireless receiver to the master unit The computer program factors in outside temperature readings in its conditioning decisions page 31 At the start of each conditioning cycle the computer signals the air pump to apply pressure and vacuum to the system This causes the dampers to inflate or deflate and conditioned air to flow Your equipment requires adequate airflow to operate correctly The computer uses information from the plenum sensor temperature and pressure to ensure enough dampers are deflated so there is always sufficient airflow The number of deflated dampers therefore rooms receiving conditioning can vary depending on the plenum readings and current inside temperatures Airflow pressure Normal and Quiet mode settings can also affect the number of open dampers Special Case Homes With Two Air Handlers If you have two air handlers you also have two main displays Each main display lists al the rooms in the house on the Advanced Room Controls Smart Controller Properties and energy history Status screens if you chose to connect the air handlers On the energy history Status screen you might notice for example some rooms cooling at the sa
8. 24 7 Support Hotline support homecomfortzones com 1 877 509 1200 Printed in the U S A HCZ DOC 100 0001 V4 3 MAY 2008 yi aoe HOME Comfort Zones 8239 SW Cirrus Drive Beaverton Oregon 97008 Business Hours 8 00AM 6 00PM PST Monday Friday Main Phone 1 800 396 0523 After Hours Support 24 hours 7 days a week 1 877 509 1200 www HomeComfortZones com
9. Programmable Zones screen press the Zones button to open the Zones Menu screen By default All Other Rooms lists the total number of rooms in your house In this example there are 14 rooms Next press Add Zone The Rooms in Zone screen appears Notice that all rooms in the house are currently in the All Other Rooms zone The room buttons display each room s name and current zone loca tion Press on the room buttons to select and un select them On the Rooms in Zone screen pick the room s you want in the zone you are creating then press OK The New Zone Name not shown screen appears where you can type in the name of the new zone The following examples describe the procedure in detail After creating a zone set its comfort schedule as described in section Setting Comfort Schedules for Your Zones on page 28 continued 25 Selecting a Thermostat Mode Programmable Zones Thermostat Mode continued Rooms in Zone New Zone All Other Rooms Living Room All Other Room All Other Room 26 Example 1 Creating a Zone for One Room The name of the room appears as the zone name on the New Zone Name screen Example 1 Creating a Zone for One Room Suppose you want the laundry room to be the only room in a zone because it doesn t require as much conditioning as other rooms Starting from the Programmable Zones screen press the following sequence of buttons Zones gt Add
10. See Cost Prediction Change Day Grouping ud 7 00 am eae lt Add Time Cost Predictions Compare Costs to The fixed settings entered below The fixed settings in effect now select again to reset The settings in effect whenever THERMOSTAT is pressed Yearly Heating Cost Heating Temperature Yearly Cooling Cost Cooling Temperature 53 Connected Assistance Note For urgent issues always call the Home Comfort Zones support hotline at 1 877 509 1200 To use Connected Assistance do the following If you have a connected Home Comfort Zones modem which is 1 Click on the Connected Assistance button as shown at left and then click Create to start the process installed at Home Comfort Zone s discretion to help us monitor our Sus tomer SUR ort torman es Bose Noni 8 equipment you can access the Note On the screens that follow click Submit Now at any time to submit your ES Home Comfort Zones Connected HOME Comfort Zones Customer Support 1 800 396 0523 After Hours 1 877 509 1200 Connected Assistance Assistance service for customer support issues This service allows you to submit questions and problems request directly to our customer support department Submitting a request via modem provides detailed diagnostic information about your system that the support staff can analyze to best address your issues Connected Assistan
11. Zone gt Laundry gt OK The New Zone Name screen appears as shown at left Since you selected one room the system assumes you want the name of the zone to equal the name of the room The name of that room appears on the keyboard screen You can delete this name and type in a new zone name if you d like Pressing OK confirms the zone name as Laundry You now have 13 rooms in the All Other Rooms zone and one room in the zone named Laundry Remember the zone is a container so if another room in your house for example the pantry would benefit from the laundry zone s temperature schedule you can add it at any time At this point you could rename the zone so it better represents its Selecting a Thermostat Mode Programmable Zones Thermostat Mode usage For example Utility Rooms Note on keyboard usage Use the Back key to delete characters one at a time After creating a zone you are ready to program its comfort eet and the Shift key to capitalize letters schedule The process is identical to defining a comfort schedule within the Programmable thermostat mode See page 21 for details Example 2 Creating a Zone for Multiple Rooms Now suppose you want your upstairs rooms to follow the same temperature schedule Rather than program each room separately you can create a zone named Upstairs and place the rooms in it Follow the procedure as described for example one In this case however in the room Rooms in
12. all the airflow from your HVAC Since the system is smart it also heats just enough receive conditioned other rooms to satisfy the HVAC equipment How does the system decide which rooms to condition It usually chooses the rooms that are closest to their lower limit However there are also parameters you can set to advise the air when you re y ets i system how to make decisions that better satisfy your needs Not only is the system smart it will take advice from not expecting it you This is normal and i P The important concept to remember is that some rooms may receive conditioned air when you re not expecting it necessary This is normal and necessary for the HVAC equipment 10 Important Concepts The Temperature s in the Feeling And You May Be Surprised The installer set your system to function in Programmable thermostat mode with a simple schedule The three possible thermostat modes are described in the following sections but we strongly recommend that you use the factory installed program for a few days so you and your family can experience the feeling of every room maintained within your comfort range at all times As needed adjust the lower and upper limits to match your comfort range You may be surprised to find that a temperature you previously thought you preferred is either too cool or too warm For example suppose you are accustomed to a house where 74 F at the thermostat produces 68 F in your fa
13. equipment or 2nd stage cool depending on your HVAC system Use this screen to define when to turn on any staged conditioning equipment you may have This can include Multistage Control Stage conjunction with a heat pump that is also referred to as backup or e An auxiliary heat source typically electric strip heating in emergency heat In extreme cold the heat pump loses efficiency and Stage vation effectiveness and the auxiliary heat source comes into action If conditioning need FOME Eei E fele e A 2nd stage heat source that some furnaces use when the single stage If temperature isn t adequate to heat the house outside is below If any room is outside 3 i 2nd stage cooling source that some air conditioners use when the its comfort zone by single stage isn t adequate to cool the house The screen at left shows the values set for second stage heat Press the arrows to redefine when to use this heat source If any of the three conditions are met the second stage heat source starts In general the sooner you set your staged equipment to start the higher your energy usage 38 Multistage Control Usage Details If conditioning need is not met after Set the amount of time the Ist stage equipment runs before you switch to the auxiliary or 2nd stage If the 1st stage does not meet the heating or cooling limit within the allotted time the auxiliary or 2nd stage activates For auxiliary heat consider se
14. knows how to prioritize if needed Circulation For the specified room s choose one of the following e High the default The temperature of a room set to High tends to stay near the same temperature This is the most cost efficient setting The system uses circulation before active conditioning when these rooms near their limits The air in these rooms is used to balance temperatures in other rooms e Medium The air in these rooms is used to balance temperatures in other rooms e Low The room rarely if ever participates in circulation A room set to Low experiences the greatest temperature variation Usage Scenarios Airflow This setting is most often used to change sensitive rooms from normal airflow pressure to quiet airflow pressure Sensitive rooms are those whose occupants prefer as little airflow noise or breeze as possible Note Quieting a few rooms often results in less airflow noise but less control within the house in general because more ducts are open at any given time continued 47 Advanced Room Controls continued Anticipation Disable anticipation for example if the furnace or air conditioner is close to your bedroom and turning it on too early wakes you up Extra Heat and Extra Cool You most often adjust this setting higher than Normal the default for rooms that you determine the system can use to store extra heated and extra cooled air In general these are rooms such as utility
15. rooms whose temperatures can fluctuate without discomfort to you Storage rooms for extra heated and extra cooled air can be important if you have other rooms that habitually draw high quantities of conditioning For example suppose you have a western facing room that requires near constant air conditioning during the summer Unfortunately if there are no other rooms in the house that require air conditioning the system won t start a cycle just for that room alone Remember that because of airflow requirements the system requires multiple rooms for a cycle Therefore if you have a room that s a designated storage room for extra cooling the system can initiate the cycle This usage scenario also applies to a room that require near constant heating in the winter Set a little used room to More for Extra Heat so that the system can initiate heating cycles more often 48 Room Priority Suppose in summer you let your house temperatures rise while you re at work Room Priority allows you to then focus air conditioning on those rooms you d liked cooled most quickly when you get home Likewise in winter you may allow house temperatures to drop during the day and then use Room Priority to heat the most important rooms first During extreme temperature conditions your HVAC equipment may struggle to keep all the rooms in the house at a comfortable temperature In this case for example in the summer you can focus air condition
16. smallest number of zones that serves your needs Think of a zone as a container Into this container you can add and remove rooms as desired With the procedure described in the next section Creating Zones you can create a zone named for example Bedrooms Suppose that Bedrooms uses a comfort range that sets the lower limit to 60 F and the upper limit to 75 F from 10 00 p m to 6 00 a m every night Into this container named Bedrooms you drop the names of all the bedrooms Zones makes it easy to change room usage For example if your child is ill and becomes uncom fortable with this comfort range all you do is remove the child s bedroom from the zone and create a new zone just for it Later you can easily move this room back into the Bedrooms zone By default the system starts with one zone named All Other Rooms If you have not defined any other zones then All Other Rooms displays above the days of the week on the Programmable Zones screen As you create new zones All Other Rooms becomes the container for rooms you have not placed into zones A room can only exist in one zone at a time Selecting a Thermostat Mode Programmable Zones Thermostat Mode Creating Zones When creating zones don t think of your house only in terms of regions such as the upstairs and downstairs Instead think of zones as containers that group together rooms that have similar patterns of use therefore similar conditioning needs From the
17. the extra cooling from the bottom floor This simple parameter change reduced the air conditioner s run time from 12 hours per day to four hours and with all the rooms always inside their comfort ranges This example illustrates that some features such as saver mode may not be effective energy savers when the HVAC system has significant weaknesses but that with proper adjustment our system is flexible enough to compensate 15 The Home Screen The buttons on the home screen are Home When selected indicates the system is in Home mode This is the p setting for normal day to day conditioning Away Allows you to save money by reducing conditioning when you re gone for an extended period of time four or more hours See page 20 for Disable Screen for Cleaning information about setting your away comfort ranges 86 EY Off Turns the system off Caution Your home could be damaged if the Standard Zones Energy History temperature drops below 32 F for sustained periods Ideal cece Tutorial Accesses an interactive tutorial that shows you how to program a comfort schedule Help Provides the Home Comfort Zones support phone number and an introduction to the help system If you have a Home Comfort Zones modem this button also leads you to the Home Comfort Zones Connected Assistance service See page 54 for more information about Connected Assistance Screen Controls Allows you to adjust the screen s brightness and con
18. the ER HVAC System Tae system If you are interested in turning this feature on please call the Home Time and Date Controls Protection Comfort Zones customer support center for directions Room Control About Your About Your System This screen provides you with the customer Smart Controller Advanced Rao System Properties Controls support number should you need service or have questions that are not addressed in this manual This menu also contains important technical Thermostat Mode Install Setup information regarding the software and hardware release versions This O Basic information may be required if you have a technical issue Programmable Programmable Zones Cancel ES Install Setup This screen is used by authorized dealers only Changing Q s parameters from this screen could cause your system to malfunction The HVAC System Controls button is a transition screen with the following buttons which you press to take you to other The following control buttons are described in detail in the following sections screens Up date Time and Date Conditioning with Relation to the Outside Temperature HVAC System Controls Temperature Differential and Circulation Control Smart Controller Properties e Airflow Pressure Advanced Room Controls e View Plenum Conditions e Multistage Control Outside Air Control 29 Update Time and Date System gt When you press Update Time and Date a screen appears wher
19. the following section A narrow comfort range uses more energy than a wide comfort range When there is only a few degrees between a call for heating and a call for cooling the HVAC equipment may heat a few rooms for a few minutes then We recommend immediately cool a few other rooms for a few minutes then heat then cool and so on The system does its best to using the widest satisfy all comfort ranges which may use a lot of energy Most people prefer at least a few hours between heating and cooling cycles We recommend using the widest comfort range that maintains your comfort This saves the most comfort range energy Many people use at least a six degree range that maintains P your comfort As outdoor temperatures decrease rooms start to approach their lower limits As outdoor temperatures increase rooms approach their upper limits During transition seasons when little heating or cooling is needed the rooms are more evenly spread between their upper and lower limits One Thermometer Versus Many Temperature Sensors A conventional thermostat has a thermometer plus controls for setting the temperature you desire For heating you use the controls to set the temperature at which you want heating to start When the thermometer reports a temperature below the set temperature the thermostat calls for heat The thermostat continues to call for heat until the thermometer reports that the temperature is above the set temperature With a conventi
20. to adjust the temperature schedules in your home One of the most common uses for programs are winter and summer schedules In the winter most people feel too warm if the house reaches 75 F yet in the summer feel too cool if it drops to 75 F A winter schedule might set the upper and lower limits to 65 F and 75 F respectively while a summer schedule might set them to 68 F and 78 F respectively This example is typical for a Pacific Northwest climate Temperatures for your location may vary If you have children you can create a program for use when the children are on vacation Typically they do not rise as early and they are in their rooms for some period each day 63 Glossary Air Conditioner A C The air cooling and dehumidifying components of the heating ventilation and air condition HVAC equipment which can be a heat pump or a separate air conditioner Call for conditioning The temperature reported by a Smart Controller is above the upper limit or below the lower limit of the comfort range for that room so there is a request for conditioning Circulation The HVAC system fan is running without conditioning Circulated air is only a few degrees warmer or cooler than the air in the room Circulation is an inexpensive way to balance temperatures between rooms Comfort range A range of temperatures specified by an upper limit and a lower limit Comfort schedule A schedule of comfort ranges for different times
21. view information about the current screen and how it s used Much of the information in this manual is available at the touch screen Index of Frequently Asked Questions The following frequently asked questions are answered at the end of this manual How do I set the temperature in my house Why do I have two temperatures I need to set My old thermostat only had one temperature Why does my lower limit change when I adjust my upper limit And vice versa How do I adjust the minimum separation between the upper and lower limits Most of the vents blow too hard at different times How can I reduce the airflow I m only concerned about too much airflow in one or two rooms How can I reduce the airflow to just those rooms at all times How do I reduce the airflow in my bedrooms zone at night I need ample airflow for temperature control so how do I reduce the noise How do I adjust the system to use less energy when the house is empty How do I prevent the system from cooling on a mild day or in the winter How do I prevent the system from heating on a warm day or in the summer How can I make the system use only circulation when windows are open How can I temporarily stop heating or cooling in a room How can I temporarily start heating or cooling in a room How do I adjust the time duration for a Smart Controller s temporary conditioning request How do I adjust the temperature range of a Smart Contr
22. you cannot delete the All Other Rooms zone In addition you cannot rename the All Other Rooms zone 28 Setting Comfort Schedules for Your Zones After creating a new zone you must define its temperature schedule By default the new zone is the currently active zone therefore changes you make to the displayed comfort schedule apply to that zone To adjust the zone s schedule to your needs follow the steps described for the Programmable thermostat mode starting on page 21 The steps are 1 Scheduling the days 2 Adjusting the time schedule 3 Adjusting the comfort range 4 Setting optional parameters From any zone press a comfort range to gain access to the temperature control screen which allows you to adjust the upper and lower limits and optional parameters For example you may want the upstairs zone the bedrooms to stay in Quiet mode from 10 00 p m to 6 00 a m See page 23 for details about the noise and circulation profiles Note When adjusting the comfort schedule for a zone ensure that you re making changes to the correct zone by pressing Next Zone until the zone you want to adjust displays on the screen The System Menu The System Menu accessed from the home screen by pressing the System button is the main screen through which you customize and fine tune System Menu system settings to meet your particular needs y Ome Central Control Password Protection By default password protection is off for
23. Control Always Circulate Circulation is on at all times Optimally use this setting only when your equipment requires it High The system uses circulation to keep all room temperatures as close as possible to one another Medium default The system uses circulation but allows the temperature differential between rooms to be further apart Low The system uses very little circulation to even out the temperature differentials in the home Use this setting if you want the fan to run only when the system is actively conditioning This reduces the time the fan blows but will potentially use the most energy It is always cheaper to run the fan alone to even out temperatures than to run the furnace or air conditioner Never Circulate Circulation is off at all times This setting has a significant impact on the system s ability to manage temperatures 34 Usage Scenarios Circulation Control In winter you may want to decrease the amount of air blowing through the vent In addition in non extreme seasons such as fall or spring or climates you can increase cost savings by increasing circulation In mild climate conditions the house most likely needs minimal warming or cooling circulation effectively uses the air already in the house to maintain temperatures In addition if you have a source of cool air like a basement or a source of hot air like a home office with electronics then allowing high circulation helps you red
24. MyTemp System a Room by Room Temperature Control and Energy Management Comfort Zones User Manual Congratulations Your home has the most advanced and effective residential climate control system available anywhere Years of research development and testing went into this system to achieve one goal to make every room in your home as comfortable as possible Your home should feel better than any home you have lived in before We designed the MyTemp system for ease of use while providing all the features needed to give you complete control over your comfort and energy usage While there are many things you can choose to control after initial set up the system should seldom require changes The system automatically maintains everyone s comfort all the time In fact you can forget about the system at least until you visit someone else s home When you do notice the difference please tell your friends about Home Comfort Zones They will thank you We re sure you will enjoy the system as much as we enjoy providing it We welcome feedback comments and suggestions about our system and service Please contact customer support or email support homecomfortzones com Enjoy your comfort The MyTemp Staff Legal and Other Notices e The contents of this document are subject to change without prior notice e Although the contents of this document have been carefully checked to prevent errors some may still occur If you have a
25. Zone screen select all the room located upstairs and press OK The New Zone Name screen appears with no name above the keyboard after you ve selected multiple rooms Use the keyboard to type in the name of the zone Upstairs Example 2 Creating a Zone for Multiple Rooms Use the keyboard to type the name of the new zone When you press OK the rooms appear with their new Once you create a new zone the number of rooms in the All Other Rooms zone decreases accordingly TA continued 27 Selecting a Thermostat Mode Programmable Zones Thermostat Mode continued Example 3 Moving a Room from One Zone to Another Suppose you decide that after all you want the laundry room to follow the same temperature schedule as the rest of the upstairs rooms This involves moving the room named Laundry out of the laundry zone and into the zone named Upstairs Press Zones select the zone named Upstairs then press Edit Zone Press the laundry room button then press OK Now the laundry zone is empty and you see that the laundry room is included in the downstairs zone The Zones Menu screen also allows you to Rename Zone and Delete Zone Rename Zone displays the keyboard screen Delete Zone deletes a zone and its associated temperature schedules When you delete a zone all rooms that were in that zone are automatically returned to the All Other Rooms zone The Delete Zone button only appears after you have created your first zone because
26. age 45 You may also need to reduce the quict airflow pressure from the Airflow Pressure screen page 35 which increases the minimum number of vents that open when those rooms receive airflow therefore decreasing airflow to those vents This reduces the ability of the system to control temperatures in some rooms Increase the setting for better control and more airflow to each vent In some cases the duct is not designed or installed properly so using the quiet airflow pressure is not sufficient It may be necessary to modify the vent or duct Contact Home Comfort Zones support for possible solutions How do I reduce the airflow in my bedrooms zone at night You must be using the Programmable Zones thermostat mode to reduce the airflow for a specific zone during specific times When setting the night time comfort zone for the bedrooms zone select the Quiet value for the Noise Profile parameter page 23 This increases the minimum number of vents that open when bedrooms receive airflow which decreases airflow to those rooms This also reduces the ability of the system to control temperatures in some rooms Increase the setting for better control and more airflow to each vent I need ample airflow for temperature control so how do I reduce the noise The vent cover probably makes most of the noise Try removing the cover If the noise is acceptable try using a vent cover that has more openings or fewer obstructions A vent cover
27. al Access an instructional les son to get yourself started Help View the 24 7 customer support phone number and an introduction to the context sensitive help system Screen Controls Change the brightness and contrast of the display to suit your needs Disable Screen for Cleaning Clean the screen when desired Energy History See page 51 Review the energy use for the house as well as individual rooms This screen also provides an overview of the current conditioning state for each room Using the Touch Screens The home screen and all other screens in the MyTemp Climate Control System are touch screens Touch screens are designed to be pressed anywhere using your finger or fingernail Do not use sharp objects When using a fingernail some users like to turn their hands so they can see their palms This makes it easier to touch the right spot and helps keep the screen clean We have tried to create an intuitive system In general touch an area that represents a choice you want to make or a topic you want to view This action has a visual effect on the screen or takes you to another screen where it should be clear what to do next We designed the system to minimize the chances for unwanted or unexpected outcomes Don t be afraid to explore If you make changes you don t want simply select the Cancel button which returns you to the previous screen without saving any changes you made Select the Help button at any time to
28. and days of the week Depending on your settings a comfort schedule is applicable to the house as a whole or to a particular area within the house Conditioning The HVAC system is either heating or cooling the air and there is heated or cooled airflow at several vents 64 Damper An airflow control valve in the duct system There may be one or more manual adjusted by hand dampers in a conventional duct system There are several varieties of automated dampers used in simple zone systems The Home Comfort Zones system uses a pneumatic damper at each register to independently control airflow to each room Default values Duct Fan Furnace Parameter settings as set by Home Comfort Zones before and during installation These are the values you see when you first use your system The pipes within walls floors and ceilings that carry airflow from the HVAC equipment to the vents The HVAC equipment component that generates airflow Sometimes this is referred to as a blower HVAC equipment heating component which can be a heat pump or a fossil fuel based furnace HVAC heating ventilation and A C equipment The combination of furnace air conditioner or heat pump and fan Lower limit The lowest temperature for a comfort range The system calls for heating when the temperature reaches the lower limit Parameters Plenum On the touch screen a number you input or a choice between two or more settings All p
29. arameters are initially set to default values The portion of the duct system that connects directly to the HVAC equipment The plenum carries conditioned air to the rest of the duct system The Home Comfort Zones system provides pressure temperature and humidity sensors inside the plenum called plenum sensors to monitor the operating condition of the HVAC equipment Return or Air Return Saver The portion of the duct system that carries room air back to the HVAC equipment for conditioning or circulation Most houses have only a few return air vents The airflow through the return path must equal the airflow through the supply ducts A Smart Controller setting that tells the system to use a minimum amount of energy to condition a room The room may still receive conditioning or circulation when necessary to satisfy the conditioning needs of other rooms When in saver mode the current comfort schedule for the room is ignored Select Selected Setback Supply The act of pressing an active area such as a button arrow number or word on the touch screen Many areas that you can press look like buttons If you want to adjust a parameter the general rule is to select one of its choice options A visible indication that a button has been pressed The display is inverted from normal dark changed to light or light changed to dark when the button is selected Also used to refer to the value of a multiple choice param
30. ate to increase energy savings Take care not to set the temperatures too high or too low as this may increase the time it takes the system to get a room into its comfort range Also note that there is a limit to the temperature differential you can achieve between adjacent rooms In a typical home it is difficult to achieve more than an 8 12 F differential between adjacent rooms Duration of Changes When you press the arrows on a Smart Controller the system temporarily adjusts the temperature in the room to the new setting Use the Duration of Changes arrows to define how long you want temporary temperature settings to last The default is two hours You can also choose to set the duration to last until a certain time of day The arrows cycle through the following duration choices 1 hr 2 hr 3 hr 4hr 6 hr 8 hr 12 hr 2 00 a m 6 00 a m 10 00 a m 2 00 p m 6 00 p m 10 00 p m 44 Usage Scenarios Enable Disable The disable setting is often used in homes with children so they don t accidentally change the Smart Controller settings Saver Setting For energy savings adjust these values for rooms that you often set to Saver mode from the Smart Controller which are the rooms most often unoccupied guest rooms for example Refer to the Smart Controller User Manual for more information about the Saver mode Note Use caution when setting the Saver mode for rooms in which extreme heat or cool may harm artwork pets or plan
31. ce The Connected Press the Create button to generate a Assistance button only customer support request appears if you have an A modem request can take up to 20 minutes of telephone time The modem calls a toll free number so you should not incur long distance charges An error anstalled modem message appears if the system is unable to submit your support request in which case you can try again or call the hotline 54 Connected Assistance Connected Assistance Introduction Connected Assistance allows your system to automatically connect with the Home Comfort Zones Office and submit a support request containing detailed operational data A Home Comfort Zones representative will then contact you using the method and time you specify Page lof 4 If you are having a critcal problem please call Home Comfort Zones immediately at the customer support number below Customer Support 1 800 396 0523 Connected Assistance Please indicate why you need customer support Will discuss problem when HCZ contacts me No heat cooling or circulation when expected Too much heat cooling or circulation Certain room s not receiving expected conditioning What is the priority for this support request Information Request Low priority System needs adjustment Medium priority Significant problem High priority System is not functioning Urgent priority GES Fee ee ee Page 2 of 4
32. ceable As described in the usage details section the lower the normal airflow pressure the more vents open throughout the house which can cause rooms that previously received little or no conditioning to seem noisier or breezier than usual Normally this does not decrease comfort but you can set sensitive rooms such as nurseries to Quiet mode as described on page 46 Always set as few rooms as absolutely needed to Quiet mode If you are not sensitive to airflow noise or breeziness you can increase the normal airflow pressure to increase energy efficiency In addition increase the pressure toward 100 if you only want to condition a few rooms For example you may have rooms that are always included in heating cycles because they lose heat quickly many windows By increasing the normal airflow temperature to 100 the system essentially focuses heat into one or two rooms for example rather than into three or four View Plenum Conditions The Plenum Conditions screen allows you to monitor the status of your heating ventilation and air conditioning HVAC equipment It displays the current temperature and pressure inside the ductwork near your furnace or air handler in the case of a heat pump installation The temperature is recorded in F This screen shows you how your system continually monitors plenum conditions to ensure that your equipment remains protected against extreme conditions It uses these measurements to calc
33. designed for return vents makes less noise than a vent cover with a control lever If changing the vent cover is not enough contact Home Comfort Zones support for possible solutions From the home screen access the Airflow Pressure screen with the following buttons System gt Furnace and A C Control gt Airflow Pressure continued 59 Frequently Asked Questions continued How do I adjust the system to use less energy when the house is empty On the Basic thermostat screen press the Away Setting button and then the arrows to adjust the upper and lower limits Press OK to save your settings and return to the home screen When you leave the house simply press Away on the home screen to tell the system to use your away settings How do I prevent the system from cooling ona mild day or in the winter The outside temperature can prevent cooling when a room temperature is above its upper limit The air conditioner does not run when the outside temperature is below the Never Cool when Outside Temperature is Below setting page 31 Check this setting if the air conditioner does not run when you want cooling From the home screen press the following buttons System gt Furnace and A C Control gt Conditioning with Relation to Outside Temperature Alternatively create a program page 49 For the heating season you can program the upper limits very high such as 90 F so that room temperatures never call for cooling 60
34. e you press the up and down arrows to adjust the time and date The day sas aM fee ssam e of the week is automatically selected based on the date entered A PN PN Set Time and Date Use the arrows to the left to set tine Thu 19Ju12007_ _Thu 19 Jul2007_ 19 Jul eal 30 Conditioning with Relation to the Outside Temperature System gt HVAC System Controls gt This screen allows you to define when you definitely don t want to use heating and air conditioning Conditioning in Relation Hee As long as the outside temperature is above the Never Heat Above limit to Outside Temperature the furnace remains off Likewise as long as the outside temperature is below the Never Cool Below limit the air conditioner remains off at all Never Heat when Outside Never Cool when Outside Temperature is Above Temperature is Below The Never Heat Above and Never Cool Below limits override system yN yN settings based on internal temperature settings This means for example o o that as long as the outside temperature is above 74 F the furnace stays off even if internal temperatures in the house would normally cause the wv v furnace to switch on Note The current Activity states Between Cycles when this setting prevents conditioning that would otherwise switch on Cancel times Press the up and down buttons to increase and decrease the temperature values continued 31 Conditioning
35. e current inside temperature Anticipation Disabled on the other hand causes the system to begin conditioning a room at the start time indicated by your comfort schedule Disable anticipation if for example conditioning noise wakes you up too early If you have a heat pump or multistage HVAC equipment 46 Anticipation overrides the Activate aux heat if temp differential is greater than setting That is auxiliary heat turns on only if the temperature differential is greater than that specified at the time conditioning would have started if Anticipation were not enabled Extra Heat and Extra Cool These parameters define the degree to which the system allows extra warm and extra cool air to enter a room during a conditioning cycle Remember that because of airflow requirements the system conditions multiple rooms during a conditioning cycle that is these rooms are receiving extra conditioning even if only one room actually requires conditioning The choices are e Less Allows less than normal warm or cool air into this room which means that this room only receives extra air when it is already very close to its heat or cool limit In general the system tends to want to allow extra air into rooms that are already near their upper or lower limits e Normal default setting Allows extra warm or cool air into this room as needed This is the default setting and as much as possible for system efficiency leave rooms in this setti
36. eter The selected choice is marked by a dot inside a circle The choices not selected are marked by an empty circle An HVAC industry term for changing a thermostat s setting to a lower temperature for heating or a higher temperature for cooling as a way to save money There are many conventional thermostats that perform automatic setbacks based on a programmable schedule The portion of the duct system that carries conditioned air to each vent in each room The air output by the HVAC equipment conditioned air is called the supply side Touch screen A graphical display screen that senses contact everywhere on the display area Touching the screen sends continued 65 information to the control computer Glossary continued Upper limit The highest temperature for a comfort range The system calls for cooling when the temperature reaches the upper limit Vent The covering over the end of a duct that allows airflow into the room Zone A room or group of rooms that has a unique comfort schedule All rooms can be in one zone so there is only one comfort schedule for the whole house A single room can be a zone and have its own comfort schedule different from any other room Most people divide their house into two or three zones 66 67 Support Phone Numbers 68 Home Comfort Zones Company Headquarters 8239 S W Cirrus Drive Beaverton Oregon 97008 Main Phone 1 800 396 0523 503 626 2797 ext 2
37. ewer rooms require conditioning to satisfy the HVAC equipment This means each encourage room is conditioned at a higher rate and fewer rooms are conditioned that are not calling for conditioning With circulation lower airflow pressure more rooms must receive conditioning to lower the airflow pressure This means each room is conditioned at a lower rate and more rooms are conditioned that are not calling for conditioning e Use the energy history graphs to identify rooms that are calling for the most conditioning If the 24 hour heat time or cool time for a room is much higher than most other rooms then this room is causing extra conditioning in other rooms Extra conditioning occurs when a room receives conditioning even though its temperature is within its comfort range Less extra conditioning means more energy savings For these rooms reduce energy usage by reducing the need for conditioning in the rooms that are calling for the most conditioning 12 Important Concepts The simplest way to reduce conditioning is to change the upper or lower limit of the comfort range for that room especially during peak conditioning hours You can also improve the room s insulation by using window treatments blinds tinting curtains and so on adding more insulation to outside walls ceiling and floor and sealing air leaks around windows and outlets Other methods include increasing airflow to the room by improving the return air path poor air return i
38. fort range also of another zone For example do not use our system to keep a wine room at a constant 55 F while trying to maintain the rest of the house at 71 F This would require nearly continuous conditioning using heating and cooling alternately It would be like leaving the refrigerator door open at all times We recommend that you maintain three degrees continued continue 13 Important Concepts continued difference between the highest lower limit the highest temperature that calls for heat and the lowest upper limit the lowest temperature that calls for cooling Your heating and cooling equipment produces a certain amount of conditioning and this requires a certain amount of airflow at all times Even if only one room calls for conditioning a few other rooms are conditioned also This means it is not possible to just condition a small fraction of your house This limitation may cause a room to not receive conditioning when outside its comfort range or some rooms to receive extra conditioning Designing and installing an HVAC system is a human process and humans make mistakes Sometimes architecture and aesthetics are given priority over good HVAC design forcing a compromise in the location of the HVAC equipment the supply duct system or the return air paths Without special care remodeling almost always increases HVAC supply ducting and return problems The MyTemp system does an excellent job of compensating for mistakes and
39. ge Scenarios Cooling Typically the economizer kicks in automatically but this screen allows you adjust how much or how little you want to use cooler outside air in addition to the air conditioner e Adjust Start Cooling temperatures down by This setting controls how much the system continues to use the economizer into the evening and early morning The higher the value the cooler your house becomes while you sleep This in turn reduces air conditioning requirements the next day as temperatures rise Specify a smaller value if you prefer to use the air conditioner more often to maintain even temperatures throughout the day e Start when outside temperature cooler by The higher the value you specify the cooler the outside air is when the economizer starts and the more quickly the system cools room temperatures This might mean that the economizer won t start a cycle until late evening or early morning A lower value specified for this option causes the economizer to start sooner and run longer to achieve the desired result however you may prefer to cycle slightly cooled fresh air rather than use the air conditioner Note A higher value cycles in less air overall which means less pollen dust and other particles caught in the air continued 41 Outside Air Control continued filter and fewer air filter changes Stop if outside temperature below Use this setting to halt cooled outside air from blowing on you and to preven
40. hat the first time listed for the Add Time F next day is its end point For example as shown at right the comfort range of 70 F to 76 F lasts from 7 00 a m to 9 00 p m This mode requires you to first select the day or days you want to sched ule then the time ranges then the comfort ranges for those time ranges Programmed comfort ranges displayed to indicate their start and end times The process for using the programmable thermostat is described on the following pages continued 21 Selecting a Thermostat Mode Programmable Thermostat Mode continued Programmable Thermostat sss E k aan This area shows the currently active schedule in this case a E E Cost Prediction J weekday schedule lt 70 76 Select days Add Time 1 Scheduling the Days First press Change Day Grouping to select the day or days of the week that you want to group together with the same comfort schedule The currently selected days are highlighted in black Press a selected day to un select it press an un selected day to select it Press OK when you are done 22 Programmable Thermostat onl 70 76 9 00 pm Cost Prediction 2 Adjusting the Time Schedule On the left side of the screen press on the time that is closest to the time you want the new limits to begin On the next screen press the up and down arrows to adjust the time accordingly then press Add a ne
41. hen you could set the Never Cool Below temperature to 50 F which allows the air conditioning to come on anytime the inside temperature rises above your Cool limit In the party example the air conditioning turns on as soon as the living room reaches 77 F because the outside temperature is above the Never Cool Below setting Temperature Differential and Circulation Control System gt HVAC System Controls gt Circulation Control dictates how much circulation you want to use throughout the house to even out temperature differences i Temperature Differential Temperature Differential allows you to increase or decrease the and Circulation Control default six degree differential enforced by the system between the upper be A POE Circulation Control Temperature Differential and lower limits This means that your upper and lower limits must be at 5 oe 6 How frequently circulation fan Minimum Difference Between least six degrees apart For example if the lower limit is 68 F then the will be used to control comfort Heat amp Cool Set Points upper limit cannot be lower than 74 F The purpose of this differential is to O Fen naval prevent unwanted conditioning cycles that is it ensures the system does High 6 yN not constantly switch between heating and cooling Mediu e m Low Never Circulate continued 33 Temperature Differential and Circulation Control continued Usage Details Circulation
42. iet mode to lessen noise Note In Quiet mode the system opens more vents to reduce air pres sure This may cause increased energy usage and in extreme cases may not allow the system to accurately control difficult rooms Circulate From the temperature control screen you can also indi cate how actively you want to run circulation during the given comfort range Choose High Medium or Low High circulation provides the best temperature control and the most economical performance but it causes circulation to be on the greatest amount of time Low circulation means that this comfort range rarely if ever participates in circulation temperatures could vary more within the comfort range continued 23 Selecting A Thermostat Mode Programmable Zones Thermostat Mode continued This area Next Zone changes the Zones lists displays the currently active zone by cycling all your currently you through the zones you have zones active zone created s Change Day Grouping O 77 soopm 00 pm Add Time 24 Cost Prediction Cool 0 Standard The Programmable Zones thermostat mode allows you to group rooms into zones A zone represents all rooms that follow the same usage pattern and therefore have the same comfort schedule You can divide your home into any number of zones from one up to the total number of Smart Controllers you have where each Smart Controller corresponds to a room Always use the
43. ing into the master bedroom so you can sleep In winter you can focus heat into the master bedroom for the same reason Circulation For rooms such as the bathroom or home office in which papers blow off the desk you may want as little circulation as possible so adjust those rooms to Low Programming Your Comfort Schedules Note This is an advanced feature Use it only if you understand how the three thermostat modes function One of the most powerful features of your MyTemp system is the ability to save your iaga Dag Ghoupeg comfort schedules to specific programs A program is a saved comfort schedule that contains all necessary information about zones and parameter settings You can use programs for 7 00 am AE many purposes seasonal schedules party schedules school schedules versus vacation 9 00 pm 66 76 schedules swing shift versus dayshift schedules Any circumstance that changes room usage and temperature needs is fair game for its own program Using programs also saves you time because when you need to adjust your home environment you simply select the applicable program rather than adjusting all the comfort ranges for different rooms on different days at a different times Programs Menu add rename or dele frroatams Standard Away and Energy Saver Programs Add Energy Saver Program On the home screen press Thermostat then Program to view the Programs Menu screen On this screen you see that the system c
44. l room plots can tell you a tremendous amount of information Guest Bed Nook 72 about your home If you are concerned about saving energy you can use these 5 738 plots to discover which rooms are causing conditioning cycles In this example the master bath caused a heating cycle starting at about 6 p m when its temperature reached the lower limit anticipation is disabled The lower limit is 68 F at 6 00 p m You could choose to relax this limit to save energy In the upper left corner you can see how much circulation heating and cooling took place over the last 24 hours You can also see what percentage of the entire energy spent in the house was used in this room The display for the whole house is a special collection of information that continued 51 Viewing Your Energy Consumption continued Press View History on the Status screen to view the energy history for the Time Button aChoulate EB 4611 entire house The figure below demonstrates the graph for the whole house ieotHeat Zone Target Temp Cool The thick grey line plots the outside temperature while the thin lines are the i im a i low and high inside temperatures throughout the home The dashes above the H plot indicate conditioning cycles In this case the system air conditioned and circulated air but did not heat The length of the dash approximates the amount of time the cycle lasted Current cycle ae Time Conditioning cycles Circulate
45. le when you use the Basic thermostat Refer to the next section for a description of the three possible thermostat modes continued 17 The Home Screen continued The following activities may appear when you press the Activity button on the home screen Starting up Ideal Between Cycles Starting Circulation Circulating Starting Heating Heating Ending Heating Quiet Heating Starting Cooling 18 Only displayed when the system is first turned on No conditioning cycle required because your home is within all temperature limits Preparing for the next conditioning cycle The system knows it should start a conditioning activity but at the moment it can t This could be for many reasons including an outside temperature requirement or too few rooms allowed to be conditioned Preparing to start a circulation cycle Using circulation to balance room temperatures and avoid heating or cooling Preparing to start a heating cycle Performing a heating cycle The furnace has stopped but warm airflow continues while the furnace cools One or more rooms in the current heating cycle are set to Quiet mode Preparing to start a cooling cycle Cooling Ending Cooling Quiet Cooling All Off High Heating Aux Heating High Cooling Quiet High Heating Quiet Aux Heating Quiet High Cooling Performing a cooling cycle The air conditioner has stopped but cool airflow continue
46. me time other rooms are circulating depending on which air handler conditions which rooms Multistage parameters such as second stage heat and auxiliary heat apply to both air handlers You can create programs and zones from either main display for any room in the house without worry The computer knows which rooms are attached to which air handler and manages conditioning accordingly When you are in the process of adjusting parameters from one of the main displays the other main display locks to prevent anyone else from making changes at the same time A message displays to indicate that the main display is temporarily locked 57 Frequently Asked Questions How do I set the temperature in my house On the thermostat screen press the up and down arrows to increase or decrease the comfort zone setting for the house time or room The system cools when any room is above the upper limit Start Cooling At The system heats when any room is below the lower limit Start Heating At How you access the thermostat screen depends on which thermostat mode you are using See page 19 for details Why do I have two temperatures I need to set My old thermostat only had one temperature The upper and lower limits define a comfort range The system attempts to keep the temperature of each room within that range and uses heating or cooling whenever the temperature strays outside those limits See page 8 for details Why does my lower limi
47. mily room 70 F in your kitchen and 72 F in your office If you prefer 70 F you are probably used to adjusting your thermostat anywhere from 72 F to get 70 F in your office to 76 F to get 70 F in your family room You continually readjust the thermostat to maintain this temperature in the different rooms With our system you simply set the lower limit to 70 F the actual temperature you prefer Every room in the house stays above 70 F Heating Cooling Auto Change Over The system can maintain several Many people have never experienced an auto change over thermostat This is a thermostat that automatically controls gt i different comfort both heating and cooling so you don t need to change the settings on days that need both heating and cooling An auto iffi if change over thermostat works like a comfort range it has a lower limit and an upper limit The difference is that the ranges for different Home Comfort Zones system maintains several different comfort ranges for different rooms at the same time rooms at the same time Saving As Much Energy As Possible In general the default settings are a good balance between comfort and energy savings However the importance of comfort versus energy savings varies from person to person The MyTemp system provides the information and adjustments necessary to enable you to control 4 continued 11 Important Concepts continued your energy usage as well as your comfor
48. mmer you can set this extremely low to prevent the furnace from turning on Away Setting By default you set temperatures for the Home Setting Press Away Setting to set temperatures to save energy when you are gone for Pree O deus ha a Gl is long periods The default temperature settings are Heat at 60 F and Cool at system when to turn on the air system when to turn on the 85 F conditioner furnace Cost Prediction When your system was configured the installer entered a base line utility cost Using this information the system estimates how much your new temperature settings cost you on a yearly basis There are several options for calculating estimated yearly costs See page 53 for details 20 Selecting A Thermostat Mode Programmable Thermostat Mode Programmable thermostat mode allows you to define varying comfort Programmable Thermostat ranges based on time of day and day of week The screen at left appears when you ve selected System gt Programmable to define your thermo Emon rue wea mu Fr ER stat mode eo Ee Cost Prediction For example you may want the temperature warmer when you get up for work or cooler on summer weekends Standard On a given day the first listed time does not have a temperature setting above its bar because the temperature limits are carried over from the pre vious day Likewise the last listed comfort range does not have an end time associated with it because the system infers t
49. ng e More Allows more than normal extra warm or cool air into this room e In Range Allows as much extra warm or cool air into this room as necessary This is the most flexible setting and we recommend Advanced Room Controls that if there s one or more rooms in the house that you can use as a catchall for excess air for the sake of rooms that are more important to you then set this room to In Range for both Extra Heat and Extra Cool Room Priority This option allows the system to temporarily dedicate conditioning to rooms that you consider most important This causes these rooms to reach their optimal temperature faster When priority conditioning is in effect the system temporarily focuses conditioning on high priority rooms by diverting airflow from low priority rooms Once the higher priority rooms receive sufficient conditioning the system returns to conditioning all rooms that need it Priority conditioning only occurs when house temperatures are significantly outside your comfort range That is priority settings go into effect in two situations as follows e When you are recovering from a setback Refer to the glossary for a definition e On those rare occasions when extreme temperature conditions fall outside your HVAC s optimal performance range Note Setting all rooms to the same priority disables priority conditioning Setting a few rooms to High and a few rooms to Low is recommended so that the system
50. oller s Saver mode Index of Frequently Asked Questions e How do I prevent my child from accidentally changing the temperature of a room with a Smart Controller e What s the difference between the three thermostat modes e Why use the Programmable thermostat mode e How many time periods can I set for one day e Why should I use the Programmable Zones thermostat mode e What is the difference between Programmable or Programmable Zones thermostat mode and the Program button e Why use programs Important Concepts To get the most out of your system you should understand the concepts described in this section In addition see page 56 for a system diagram and a simple explanation of how the system works 1 Your personal comfort range 5 The temperature s in the feeling and you may be surprised 2 Upper and lower limits 6 Heating cooling auto change over 3 One thermometer versus many temperature sensors 7 Saving as much energy as possible 4 Our system works with your existing HVAC equipment 8 HVAC limitations Your Personal Comfort Range Your personal comfort range is a range of temperatures comfortable to you A degree higher than the upper limit and you want cooling A degree cooler than the lower limit and you want heating Each person in your home may have different comfort ranges that change from season to season room to room activity to activity You can set different comfort ranges for different rooms Yo
51. omes with three programs Standard Away and Energy Saver Standard is for daily use and Away for extended absences from the house You cannot rename or delete these programs but you can adjust their settings as described in section Adjust Program Settings on the next page You can rename delete and adjust the Energy Saver program This program is Ea recommended by the U S Department of Energy for energy conservation continued 49 If you are in Programmable or Programmable Zones mode you see the Program Programming Your Comfort Schedules continued button on the right Programs don t apply to the Basic thermostat mode because it sets one comfort zone for the entire house To use the Away schedule press Away on the home screen Pressing the Home button reapplies the last program used 1 Create a New Program To create a new program press Add Program which copies the active program currently highlighted on the Programs Menu screen Consider this copy your starting point for creating a new program Rename this program by pressing the back button to delete the words New Program that appear on the keyboard screen Press OK when you are done At any time you can rename or delete a program by pressing Rename Program or Delete Program 2 Adjust Program Settings Adjust your programs from the Thermostat screen described starting on page 19 remember that the screen you see depends on your 50 thermosta
52. onal thermostat the temperature sensing is in the same location as the thermostat Therefore the area around the conventional thermostat is the only area within the home with accurate temperature control continued 9 Important Concepts continued With the MyTemp system there are many temperature sensors spread throughout the house The Smart Controllers are the temperature sensors You cannot define your comfort ranges at the Smart Controllers you do this at the touch screen Since you probably don t spend much time near your touch screen it does not contain a temperature sensor Our System Works With Your Existing HVAC Equipment The MyTemp system works with the HVAC equipment you already have When the system senses that one or more rooms aren t within their comfort zones it initiates a heating or cooling cycle using your HVAC equipment Your equipment like all residential HVAC equipment requires a certain amount of airflow to work effectively This airflow is more than any single vent can handle Several vents must be open at all times to satisfy your existing HVAC equipment Even if only one room is calling for conditioning several rooms receive conditioned air For example imagine your kitchen is currently 67 5 F and its lower limit is 68 F and all other rooms are above their lower limit The system begins heating to raise the temperature in the kitchen but the system knows the Some rooms may kitchen vent can not handle
53. onditioned at any one time The system controls the overall pressure by inflating and deflating dampers See page 56 for a system diagram and overview In Normal mode the system inflates as many dampers as possible given the current status of you equipment parameter settings and inside temperatures This means their vents are closed and fewer rooms are conditioned At 100 the system uses the minimum number of rooms safely possible to control temperatures Quiet mode causes the system to inflate fewer dampers than it would otherwise which means more vents are open and airflow spreads over a wider area causing airflow noise to decrease but also more rooms to be conditioned Airflow noise can be caused by the ductwork s size and material composition as well as the grill type Note By reducing the Normal pressure setting or by setting a room to Quiet you reduce energy efficiency because the system is forced to include more rooms in any one conditioning cycle even if they don t require conditioning You also impact the amount of potential airflow into a room which may not allow difficult rooms that is rooms located far from the furnace or rooms with inadequate ductwork to receive adequate conditioning 36 Usage Scenarios Lower the Normal Airflow Pressure if you notice excess airflow noise or breeziness in the house in general Adjust Quiet Airflow Pressure if the noise or breeziness in a room set to Quiet mode is still too noti
54. perties See page 43 for details continued 61 Frequently Asked Questions continued How do I prevent my child from accidentally changing the temperature of a room with a Smart Controller Select Disable on the Smart Controller Properties screen See page 43 for details What s the difference between the three thermostat modes The three thermostat modes differ in their level of complexity and flexibility of temperature control See page 19 for details Why use the Programmable thermostat mode This mode allows you to save energy by reducing conditioning during times you don t need tight temperature control Let s look at an example for a weekday program 6 00 a m wake 70 F 75 F 8 00 a m leave for work reduce usage widen temperature limits 62 F 85 F 5 00 p m arrive from work tighten temperature limits again 62 70 F 75 F 11 00 p m go to bed 62 F 74 F Notice that from 8 00 a m to 5 00 p m the comfort range widens That is the furnace only starts when the temperature falls to 62 F and the air conditioner only if the temperature rises to 85 F You can program different comfort schedules for the weekends You can also create schedules for each day of the week or groups of days like Monday Wednesday and Friday How many time periods can I set for one day You can program up to five time periods for any one day or group of days This is due to the screen si
55. question about this manual or if you find an error please contact us e Except for personal use no part of this publication may be reproduced or reprinted without prior written permission from Home Comfort Zones Copyright Copyright 2008 Home Comfort Zones Inc All rights reserved Table of Contents Introductory Topics System Quick Stark ercer iecenescoasaunecenseuezaeecies Using the Touch Screens 112i tadodpinteescnteiennteateete Index of Frequently Asked Questions 05 Important Concepts yesccingsciseeeessnseesvennssnecentstarens Getting Started The Home Screen cceccceeeeeeeeeeeeteeeeeueeeeees Selecting a Thermostat Mode oii cccsssrtanasmpentaerse Basic Thermostat Mode cecccceeeeeeeeeeeees Programmable Thermostat Mode 66 055 Programmable Zones Thermostat Mode Customizing Your System The System Mei 25 s crusseescasntyrina eiudadnieeiiien Update Time and IG crrcctrnrienciemn ances Conditioning in Relation to Outside Temperature Temperature Differential and Circulation Control Airflow Pressure ccececceeeeeseeeeeceneneeceuenens View Plenum Conditions 00ecccceeececeeeeees Multistage Control lt sscontevetadisnenceatinesecsieitesvert 38 Outside Air Control c cece cece eee eeceeeenceeeeees 40 Smart Controller Properties lt icosccniinsssrtuomdarnnieses 43 Using Advanced System Features Advanced Room Controls
56. rol You can also use the Away feature if the lower and upper limits prevent heating and cooling If you normally use one of the programmable thermostat modes you can switch to the Basic thermostat mode when you want circulation only Set the lower limit to 60 F and the upper limit to 90 F How can I temporarily stop heating or cooling ina room If you want to quickly stop heating in a room press the Smart Controller s down button two or three times If you want to quickly stop cooling in a room press the Smart Controller s up button two or three times Airflow should stop within a few minutes Refer to your Smart Controller User Manual for details about Smart Controllers How can I temporarily start heating or cooling ina room If you want to quickly start heating in a room press the Smart Controller s up button two or three times If you want to quickly start cooling in a room press the Smart Controller s down button two or three times to the desired temperature Airflow should start within a few minutes Refer to your Smart Controller User Manual for details about Smart Controllers How do I adjust the time duration for a Smart Controller s temporary conditioning request Change the Duration of Changes parameter on the Smart Controller Properties screen See page 43 for details How do I adjust the temperature range of a Smart Controller s Saver mode On the home screen press System then Smart Controller Pro
57. roller Properties gt that contains a Smart Controller The Smart Controller Properties Select aroom display shows the name of the room ae Eaa Bed FEA kra whether the Smart Controller is in On or Eaa ENA FEA ENA Saver mode and whether it is enabled or Select All disabled ee ae Rooms ee ENA ae ENA Edit Selected Press a room or group of rooms then Family Room Room s press Edit Selected Room s to change ON ENA ENA Smart Controller settings for those rooms Peto Bed eel Bath You can also press Select All Rooms to Peto ENA eel ENA change the Smart Controller parameters F f ENA Bath eee Bed Smart Controller Properties for the entire house Fea ENA eee ENA Saver Mode Set Points The Select No Rooms button deselects an alea eee nia E e the current highlighted rooms Heat when room temperature below Refer to the Smart Controller User Manual Override Control for details about how to use your Smart Aaintain PateT 2hrs h override for rs Controllers Allow Local Override ENABLE DISABLE EA continued 43 Smart Controller Properties continued Usage Details Enable Disable Disable the selected Smart Controller s and re enable them as desired Disabled Smart Controllers report temperature information but you can t use the buttons Saver Setting Define the upper and lower limits to use when you place a Smart Controller in Saver mode These limits should correspond to a relaxed conditioning st
58. s a common problem increasing the size of the duct serving the room or adding another duct and vent to serve the room HVAC System Limitations Even the best HVAC and duct system has limitations For example heating and cooling capacity is based on the local average climate so a record setting hot or cold day may require more cooling or heating capacity than the equipment can supply With HVAC equipment extra capacity is not better Oversized equipment operates less efficiently and can cause temperature control problems So a properly designed system will be most efficient all of the time and have the capacity to keep you comfortable 99 of the time However for a few hours on the hottest or coldest days the temperature in a few rooms may go outside their comfort ranges The interior walls of homes are not good insulators so it is relatively easy for heat to flow between rooms especially Even if only one when the doors are open or if the rooms share a wall Therefore it is not possible to maintain a large temperature rooms calls for difference between nearby rooms For example in winter a room in saver mode may get only 10 degrees cooler than conditioning a the heated room next to it A room next to a room in saver mode will need more conditioning because of heat flow through the wall between the rooms few other rooms are conditioned It is not practical to set the upper limit of the comfort range in one zone less than the lower limit of the com
59. s while the air conditioner warms One or more rooms in the current cooling cycle are set to Quiet mode The system opens more vents to reduce airflow noise The system was turned off For multistage equipment using the high stage to heat the home For multistage equipment using secondary heating to meet current heating needs For multistage equipment using the high stage to cool the home For multistage equipment using the high stage to heat the home with one or more rooms set to Quiet mode For multistage equipment using secondary heating to meet current heating needs with one or more room set to Quiet mode For multistage equipment using the high stage to cool the home with one or more rooms set to Quiet mode Selecting a Thermostat Mode You can choose one of three thermostat modes to control your home s temperature as follows Basic This is the simplest mode Basic mode allows you to set a lower limit and an upper limit for the entire house The system applies your settings to all rooms in the house but only conditions rooms that go outside their limits Programmable Similar to Basic mode in that it applies settings to all rooms in the house However in this mode you define comfort schedules based on time of day and day of week This allows you to save energy because for example you can set the system to condition less while you re asleep or at work The possibilities for cost savings extend to anytime
60. t Your system can help you save energy in several ways The following suggestions are described in detail later in this manual e Use the widest comfort ranges possible Decrease the lower limits to use less heating and increase the upper limits to use less cooling e Divide your house into zones in which the rooms in each zone have the same usage pattern during the week Use wider comfort ranges when the zones are unoccupied especially for more than four hours The system automatically estimates the change in yearly energy costs as you adjust the comfort schedules for different zones Proper settings save energy without affecting the comfort in rooms when they are occupied e Use the Smart Controller saver mode in rooms that are not being used every day e Use the away mode whenever your home is unoccupied for more than four hours If you set your return time your home will be comfortable when you return e Use settings that encourage circulation Circulation saves energy by moving heat from an area with too much heat to an area that can use heat This is especially important if you have a multi story home since warmer air rises to For greater the top floor while cooler air falls to the bottom floor Circulation helps balance temperatures between floors energy savings without using conditioning use settings that As much as possible maintain airflow pressure at the highest setting with which you are comfortable Higher airflow pressure means that f
61. t change when I adjust my upper limit And vice versa To ensure the system does not constantly switch between heating and cooling the upper and lower limits must be at least three degrees apart The system automatically adjusts the limits when you set them too closely By default the system enforces a six degree separation 58 Note We recommend at least a six degree separation which allows adequate comfort while avoiding unwanted conditioning cycles See page 33 for details How do I adjust the minimum separation between the upper and lower limits From the home screen press System gt Furnace and A C Settings gt Temperature Differential and Circulation Control See page 33 for details Most of the vents blow too hard at different times How can I reduce the airflow The normal airflow pressure setting controls the overall airflow On the Airflow Pressure screen page 35 lower this setting to reduce the normal airflow which increases the minimum number of vents that always open so the airflow to each vent lessens This also reduces the ability of the system to control temperatures in some rooms Increase the percentage for better control and more airflow to each vent Frequently Asked Questions I m only concerned about too much airflow in one or two rooms How can I reduce the airflow to just those rooms at all times Select the rooms and set the airflow to quiet using the Advanced Room Controls screen p
62. t circulating outside air if there is a risk of condensation Fresh Air 42 Minimum fresh air per day Building codes in some states require new homes to be built with fresh air intake valves that add fresh air to the house for one hour every 12 hours two every 24 hours This is considered a minimum recommendation for air freshness in newly constructed homes However the actual amount of air required to keep the air feeling fresh varies from home to home and person to person If you only want fresh air added to the house during regular conditioning cycles lower this value to zero Maximum fresh air per day In general adding fresh air to the house doesn t change your comfort Therefore you can raise the maximum hours of fresh air as desired while considering the following In extreme climates circulating high quantities of fresh air may cause a slight increase in energy usage because the system needs to condition the fresh air to within your comfort range Springtime allergens may require you to minimize fresh air intake Less fresh air intake results in fewer air filter changes Allow fresh air only at these times During winter in a colder climate you may choose Day to prevent colder air from entering the house at night In summer in a warmer climate you might choose Night for effective use of cooler air temperatures Smart Controller Properties This screen lists every room in the house System gt Smart Cont
63. t mode When you change a comfort schedule you are actually editing the copied program That is you are creating a variation of the program you used as a starting point When you leave the Thermostat screen by pressing OK the system saves all changes 3 Change Programs Anytime you want to switch programs press Program on the Programmable or Programmable Zones thermostat screen highlight the applicable program and press OK This is now your active program Viewing Your Energy Consumption Press Energy History on the home screen to view the Status screen This screen allows you to access the previous 24 hour history of your home STATUS Select aroom to view its current status Back Bed Kitchen Office 738 73 718 temperatures and current conditioning cycle if any A line in place of a temperature indicates that the Smart Controller is not communicating with Parasa spl gt the system If this persists contact customer support Family Room ig Room 728 i Press on a room to view its 24 hour energy history The figure on the next fie The screen lists the rooms that contain Smart Controllers their current page shows the history for the master bath The thick gray lines are your Front Bed Mester Bath Current Outside 713 73 5 Temperature dark line is the actual temperature over the previous 24 hours Guest Bath Master Bed 725 72 5 upper and lower limits for the room at different times of the day The thin The individua
64. tab to define when to turn on and turn off your outside air economizer Outside air economizers cost effectively lower indoor temperatures by swapping indoor air with cooler outside air generally at night or early morning when temperatures are at their coolest Cooling temperature minus the specified value e Start when outside temperature cooler by Starts the 40 Outside Air Control economizer when the outside temperature falls below room temperatures by the specified amount This tells the system how long to wait before starting the economizer The system starts the economizer when enough rooms meet this criteria Stop if outside temperature below Turns off the economizer if the outside temperature drops below the specified temperature Fresh Air Use the arrows to adjust the settings Minimum fresh air per day Specifies the minimum number of hours the system opens the fresh air vent in a day The system starts a conditioning cycle just to bring in fresh air if the minimum wasn t met during regular conditioning cycles Maximum fresh air per day Specifies the maximum number of hours to allow fresh air circulation during normal conditioning cycles The system opens the fresh air vent when cycles are already being run and never starts a conditioning cycle simply to reach the maximum limit Allow fresh air only at these times Specifies when to allow fresh air into the house Your choices are Anytime Day and Night Usa
65. to use the following Active auxiliary heat after 30 min Activate aux heat if the outside temp is below 40 F Activate aux heat if temp differential is greater than 5 F On the other hand if you use electric resistance or strip heating as your backup you may want conservative settings to save money Active auxiliary heat after 120 min Activate aux heat if the outside temp is below 30 F Activate aux heat if temp differential is greater than 10 F 39 Outside Air Control System gt HVAC System Controls gt Press here Note This button does not appear on the HVAC System Controls screen if you don t have outside air equipment This screen contains one or two tabs depending on your configured equipment Press on the tab s label to adjust your outside air controls Adjust Start Cooling KI B temperatures down by 4 2 Start when outside temperature cooler by Stop if outside temperature below Fresh Air Use this tab to adjust how many hours within a 24 hour Outside Air Control period you would like the system to circulate in fresh air during Coolin g Fresh Air conditioning cycles to refresh inside air tinimum fresh air per day 2hrs Usage Details Maximum rena hrs Cooling Use the arrows to adjust the settings oe Pawara anytime e Adjust Start Cooling temperatures down by Starts an economizer cycle when inside temperatures are above the Start Press here Cooling Use this
66. trast as well as convert to white text on a black background Disable Screen for Cleaning Disables the screen for 20 seconds so you can clean it Caution Use a soft damp cloth not cleaning solutions which can damage the display 16 The Home Screen Energy History Provides a 24 hour history of temperature and HVAC system use in your home You can also check each room for its current temperature and system status System Allows you to customize your system settings as described starting on page 29 Thermostat Allows you to adjust your upper and lower limits You see one of three screens depending on which thermostat mode you choose These modes are described in the following section Press anywhere in the region shown at right to Inside Current temperature at a designated Smart Controller that was chosen by the installer to represent the Inside wes 86 Standard Zones Ideal view the current system activity A screen appears that describes the reason for the current inside temperature activity This screen not shown contains three activities Heating Cooling Outside Current outside temperature as reported by Circulating that you press if you are the outside temperature sensor interested in why a particular conditioning function is or isn t currently active Current Program Program that is currently active S y This area shows the current activity This area is not visib
67. ts Duration of Changes As described in the Smart Controller User Manual you most often temporarily change temperatures in rooms with sporadic usage schedules The duration of these changes reflect how long you generally use these rooms and therefore how long you would like the temporary settings to last As an example you may want to increase the duration of change for the Smart Controller in a guest room when it s in use this way any temporary changes your guest makes will last longer than the default two hours In general you use the controls on this screen to adjust rooms that are habitually hot or cold fix inherent problems in the house and overcome problems with the ductwork capacity For each room with a Smart Controller the screen shows whether the room has airflow in Normal or Quiet mode and whether the room is Anticipation enabled The display also indicates the level of circulation set for that room high H medium M and low L Advanced Room Controls System gt Advanced Room Controls gt Advanced Room Controls Select a room Back Bed Kitchen Office NORM ANT H NORM ANT H NORM ANT H Exercise Laundry Utility NORM ANT H NORM ANT H NORM ANT H Family Room Living Room NORM ANT H NORM ANT H Front Bed Master Bath NORM ANT H NORM ANT H Guest Bath Master Bed NORM ANTH NORM ANT H Guest Bed Nook NORM ANT H NORM ANT H Select a room press Rename and then use the
68. tting this to at least 60 minutes because it is typically more expensive to operate than your heat pump If temperature outside is below Use 1st stage equipment until the outside temperature falls or rises for 2nd stage cool to the temperature you specify For auxiliary heat for example most heat pumps lose efficiency below about 30 F Depending on your comfort versus savings priorities you can set this selection from 40 F for comfort to as low as 30 F for cost savings If any room is outside its comfort zone by Ensure that your home never falls below or rises above for 2nd stage cool a given comfort range For auxiliary heat for example suppose your upper limit is 72 F and you set this differential to greater than 10 F Next suppose that the house has been in Away mode and therefore cooled down to 60 F When you press Home on the main display the system sees that you have a 12 degree differential to make up and will use auxiliary heat to quickly bring the house back up to 72 F Usage Scenarios Typically the HVAC starts automatically but this screen allows you to define how little you want to wait for auxiliary heat 2nd stage heat or 2nd stage cool to help bring temperatures into their comfort range For auxiliary heat settings are dependant on the type of auxiliary heat you have If you have a high efficiency gas furnace as your backup heating source then you can be more aggressive with your settings You may want
69. u can set comfort ranges to automatically follow a weekly schedule and you can save these schedules as programs Upper and Lower Limits cooling starts You set comfort ranges using the touch screen For each comfort range you set an upper limit for the 74 F Upper Limit temperature that causes air conditioning to start and a lower limit for the temperature that causes heating to start The system turns on heating or cooling as needed to keep the temperature between the limits It even uses circulation to help balance temperatures between rooms when heating or cooling is not required Circulation is only used when it is cost effective for balancing temperatures The system saves 68 F Lower Limit energy by reducing conditioning when possible and it turns off circulation when unhelpful or unneeded Important Concepts The lower and upper limits must differ by at least three degrees We recommend a six degree separation Most users don t notice a few degrees of difference as long as they are inside their comfort range However one degree outside the comfort range can be uncomfortable Therefore the system s priority is to keep every room inside its comfort range This means that sometimes a room may be heated even if it is a few degrees above its lower limit Or it may be cooled when it is few degrees below it upper limit It may receive circulation even if it is in the middle of its comfort range The reasons for this are described in
70. uce energy costs because the system has wide latitude to direct cool air to the warmest rooms and warm air to the coolest rooms This means that if you have a 65 F basement and an 80 F second story bonus room the system attempts to even out their temperatures with circulation rather than active conditioning Temperature Differential The standard six degree differential is considered the optimal balance between comfort and energy efficiency At this differential the system uses circulation as often as possible to help balance temperatures For the most savings you may increase the differential a few degrees However if you find that you require a tighter comfort range decrease the differential to a minimum of three degrees Airflow Pressure System gt HVAC System Controls gt Airflow Pressure allows you to set the amount of air pressure for the whole house as a percentage of the maximum airflow The system uses the Normal pressure setting unless you ve set a room to Quiet mode See the Airflow Pressure usage details section on the next page for information about Quiet mode For energy efficiency use the Normal setting as often as possible and as close to 100 as possible Airflow Pressure Limits Airflow pressure for NORMAL BET Airflow pressure for QUIET rooms amp times continued 35 Airflow Pressure continued Usage Details Quiet mode is one of the many factors that changes how many rooms are c
71. ulate how many dampers it can safely inflate to regulate temperatures Usage Details Press the arrow next to Conditions for Stage to cycle through Circulation Heating and Air Conditioning to view the current temperature as well as the temperatures recorded at the end of the previous cycle and in all cycles run over the previous day None displays when there has been no usage in the past 24 hours The pressure readings are relative measurements and are currently for internal use only A Switch Plenum button not shown appears on the bottom of the screen when you have twinned HVAC systems Use this button to view the temperatures recorded for the secondary HVAC system System gt HVAC System Controls gt Plenum Conditions Conditions for Stage Circulation Current Last Cycle Recent Cycles Min Max Min Max NONE NONE NONE NONE NONE NONE NONE NONE Temperature 74 Pressure 0 000 Humidity NA Usage Scenarios As an example the Activity may state Heating but no heat is actually circulating By checking this screen you can check whether or not the furnace is working In addition access this page when speaking with customer service representatives The data can help diagnose problems 37 Multistage Control System gt HVAC System Controls gt Note This button does not appear on the HVAC System Controls screen Press here to choose between auxiliary heat 2nd stage heat if you don t have multistage
72. w time You ll see the new time listed along with the others on the Programmable Thermostat screen Alternatively you can press Add Time on the Programmable Thermostat screen This button doesn t appear when you have five Selecting a Thermostat Mode Programmable Thermostat Mode times already listed on the screen Depending on what s already programmed you may need to adjust a previously listed time to complete the new time range Do this by pressing on the time and then adjusting it with the up and down arrows Press OK When you increment the hours past midnight or noon the AM PM indicator changes Also notice that you can only change the minutes in 5 minute increments To delete a time from the schedule press on it and then press Delete this time 3 Adjusting the Comfort Range On the Programmable Thermostat screen press the comfort range that you want to adjust For example 70 76 On the next screen that appears a temperature control screen similar to that shown on page 20 use the up and down arrows to adjust the upper and lower limits of your comfort range and then click OK to save your changes 4 Setting Optional Parameters The temperature control screen for the programmable thermostat mode differs from that shown on page 20 which is for basic mode in that it includes two buttons as follows Noise Profile From the temperature control screen you can choose to place the given comfort range in Qu
73. weaknesses and keeps all rooms as comfortable as physically possible A Practical Example Sometimes inadequate ducting causes unsatisfactory results that you can overcome with a simple change in parameters The following scenario occurred within an extensively remodeled house built about 1910 Our system is flexible enough to This house contained three rooms on the top floor each with one small duct One room was unused so it was placed on saver mode On hot days the air conditioner ran continuously to keep the other two rooms cool but their compensate for d ao temperatures always remained above their upper limits Rooms on the bottom two floors also had to receive inadequate conditioning to satisfy the HVAC equipment causing so much extra conditioning that they became uncomfortably ducting cool The problem was that the two ducts into the rooms on the top floor not in saver mode were not enough to keep the top floor cool because of the additional heat leaking in from the room in saver mode 14 Important Concepts The simple and unexpected solution was to take the unused room out of saver mode so that it also received air conditioning The airflow through three ducts was enough to cool the top floor so the temperatures in all three rooms dropped into their comfort ranges Circulation immediately started mixing the warmer top floor air with the cooler bottom floor air This reduced the need for cooling the top floor while recovering
74. with Relation to the Outside Temperature continued Usage Scenarios Use this screen to block conditioning in winter or summer for increased energy savings For example if you never want the air conditioner to start in winter set Never Cool Below to 65 F Or if you never want the heater to start in summer set Never Heat Above to 50 F The system uses circulation when it can to circulate cooler air in the summer and warmer air in the winter In general a typical well insulated home has approximately 10 degrees of thermal gain This means that when it is 65 F outside the inside temperature is at least 73 75 F If you are interested in saving energy set the Never Heat Above temperature to 60 F and the Never Cool Below to 65 F This prevents air conditioning in the winter and should eliminate unnecessary heating in the summer In addition to seasonal considerations suppose your Never Cool Below temperature is 65 F and you decide to have a party in December Assume 100 people arrive and the outside temperature is 58 F Because you have 100 people in a small confined space the temperature in your living room could easily reach 80 F Even if your upper limit is 77 F your air conditioner does not turn on because the outside temperature is below the Never Cool Below temperature In this case you save energy by simply opening the windows to cool off the room 32 If your priority is comfort rather then energy savings t
75. your room usage patterns change and anytime seasonal changes and other circumstances affect your comfort schedule Programmable Zones Same as Programmable mode except that now you can group rooms into zones with their own comfort schedules based on time of day and day of week This allows you to customize your home based on room usage patterns System Menu Central Control Update HVAC System Password Time and Date Controls Protection Room Control About Y Smart Controller Advanced Room Properties Controls Thermostat Mode Basic Programmable Programmable Zones To set the thermostat mode press System on the home screen and then select either Basic Programmable or Programmable Zones As shown above Programmable Zones mode is selected continued 19 Selecting A Thermostat Mode Basic Thermostat Mode Basic thermostat mode allows you to set a lower limit and an upper limit for the entire house The screen at left appears when you select System gt Basic This is the temperature control screen Start Cooling At This is the upper limit and indicates the warmest indoor temperature you allow before air conditioning begins The higher this Cost Prediction Cool 0 temperature the greater the energy savings Heat 0 Start Heating At This is the lower limit and indicates the coolest indoor temperature you allow before heating begins The lower this temperature the greater the energy savings In the su
76. ze If you would like more than five time periods please contact us Why should I use the Programmable Zones thermostat mode There are two major reasons for using zones Energy Savings By grouping rooms into common functions you may be able to reduce energy usage For example you can zone all bedrooms Frequently Asked Questions together so that you can reduce heating at night and during the day when they are not used You might group adult rooms in one zone and children s room in another zone to maximize comfort and energy savings Optimal Comfort There are dozens of circumstances that may warrant special temperature considerations These can include exercise and guest rooms home offices nurseries walk in closets music rooms home theaters and so on You can create a zone for each circumstance What is the difference between Programmable or Programmable Zones thermostat mode and the Program button Programmable and Programmable Zones thermostat modes allow you to create comfort schedules for each day of the week The Program button allows you to save these schedules so that you can switch between them easily See page 49 for details on how to use programs Why use programs A program is a convenient way to rapidly change your settings for different circumstances For example if you are a shift worker and your schedule changes every few weeks then creating programs named Day Swing and Grave is the fastest way

Download Pdf Manuals

image

Related Search

Related Contents

XtremeMac Microshield  La stratégie c`est :  User manual for the AgileRRAgileRR 2.0 Playout  Manual del propietario    MOD. JPP - BilanceOnLine  Manual De Revision Del Motor 300 Tdi  user instruction manual dbi-sala advanced digital winch  Danby DUFM30WDD User's Manual  installationsanvisning installation manual  