Home
Product User`s Manual
Contents
1. FINE WIRE OR CONDUCTIVE PAINT CONCEALED MICROPHONES CONNECTED BY WIRES TO THE LISTENING POST 1 Turn on a sound source such as a radio in the target room Next turn on the TD 62 and set the MODE switch to VERIFY gnore any indications on the LED meter Make sure the LINE DRVR LED on the P 03 is OFP 2 Connect the P 03 alligator clips to the wires being tested NOTE We DO NOT recommend that you perform any tests with this equipment on live AC power wiring or you will damage the P 03 and TD 62 If necessary scrape just enough insulation off the wires to expose them for the alligator clips After the tests are completed cover the scraped areas with electrical tape 3 Operate the A B switch to both positions If the red LED above the line driver comes on in either position a DC voltage is present on the wire pair If the red LED is on in both positions an AC voltage is present If a voltage is indicated use standard safety procedures when working with the wire pair CAUTION If either an AC or DC voltage is indicated DO NOT operate the LINE DRVR switch or damage will occur to the P 03 and TD 62 4 Turn up the TD 62 volume control to a comfortable level and listen for room audio If the line has no voltage present turn on the LINE DRVR switch to apply voltage to the wire pair Operate the A B switch to both positions and listen for room audio Shield the green LED from room light and observe it for any glow of light
2. The center jack is used to attach one of the four probes The jack to the left side is used for the included ear bud under reduced volume SUMMARY amp LIMITATIONS The best way to become proficient with the TD 62 is to practice A reasonable and readily available practice transmitter is a child s 49 MHz walkie talkie For the most effective practice get someone else to hide the test transmitter for you The person hiding the transmitter should be reasonable Just tape down the transmit button turn the unit on and have someone hide it Then practice finding the transmitter using both the DETECT and VERIFY modes The clicking in the DETECT mode or the squeal in the VERIFY mode can alert the eavesdropper that you re on to him For this reason we have provided an earbud jack to be plugged in on the top left corner of the TD 62 Just plug in the supplied earbud and you ll be able to hear the clicking in the DETECT mode with no trouble In the VERIFY mode keep the volume turned down to protect your hearing in case a feedback squeal is set up P 01 PROBE SPECIFICATIONS Frequency Response Covers 5 MHz to 2 5 GHz Detection range may vary depending on factors such as construction antenna placement furnishings and most importantly transmitter power Plug the P 01 probe into the center jack and extend the telescoping antenna Walk slowly around the room while sweeping the probe antenna slowly up and down from ceiling to floor
3. Also turn on the various lamps and appliances as you come to them to activate any bugs that may be hard wired When a FF field is detected the red signal LED on the Wideband RF probe will light the bar graph in the display of the TD 62 will grow in size and the clicking rate will increase At this time slowly sweep the probe from side to side to get a bearing on the transmitter s direction This would be a good time to place the TD 62 in the low sensitivity setting to help pinpoint the transmitter Pay close attention bugs are very small and easily hidden Never end the sweep when you find a bug When someone is serious about invading your privacy they will seldom rely on just one bug in one room P 02 INFRARED PROBE SPECIFICATIONS Field of View 50 degrees Spectral Peak 880 nm infrared THEORY Light beams especially lasers provide an excellent method for carrying audio intelligence The light beam can be visible or invisible as in infrared They can carry conversations for long distances with most manufacturers claiming a range of several kilometers And most importantly modulated light attacks are often not considered by individuals performing countermeasures checks This can be a fatal oversight from a security standpoint The P 02 is a special probe designed for use with the TD 62 Transmitter Detector which allows the technician to search for sources of infrared IR transmissions In the case of amplitude modulated
4. If you see any light from this LED that means that current is flowing in the wire pair and a listening device could be connected to the wires The brightness of the LED indicates the level of current that is flowing 5 Perform the above checks on any other suspicious wire pairs in the target area A complete check of the target room would also include listening for room audio on any telephone wires present The reason for this is that a telephone can be modified through a technique known as hook switch bypass When so modified the telephone acts as a microphone and intercepts all room conversations and passes them down the phone line even while the phone is hung up If room audio is heard on the phone line the telephone should be checked for the hook switch bypass attack P 04 MICROWAVE RF PROBE SPECIFICATIONS Frequency Response Covers 2 5 GHz TO 6 GHz Detection range may vary depending on factors such as construction and most importantly transmitter power Note The operation of the P 01 and the P 04 are identical in everything other than frequency response and should be used in the same method Plug the P 04 probe into the center jack and ensure that the antenna is secured finger tight Walk slowly around the room while sweeping the probe antenna slowly up and down from ceiling to floor Also turn on the various lamps and appliances as you come to them to activate any bugs that may be hard wired When a Microwave RF field
5. if you just Suspect a tap but if you have the physical evidence they should be willing to investigate Remember wiretapping is a Federal crime as well as a violation in most states LIMITATIONS While the Tap Trap will detect the most common on premises wiretaps and hookswitch bypasses there are some it won t detect These include drop in transmitters bypasses activated by high voltage and inductive taps that don t have a physical connection to the phone or line In addition to the drop in transmitter other series RF radio transmitter taps can be installed inside the telephone These can be located with any of our RF detectors The high voltage bypass is rarely used as is the inductive tap Both can be located by close physical examinations of the telephone and or inside wiring Of course the Tap Trap does not detect off premises wiretaps such as court ordered taps that are connected by the phone company
6. is detected the red signal LED on the Microwave RF probe will light the bar graph in the display of the TD 62 will grow in size and the clicking rate will increase At this time slowly sweep the probe from side to side to get a bearing on the transmitter s direction This would be a good time to place the TD 62 in the low sensitivity setting to help pinpoint the transmitter Pay close attention bugs are very small and easily hidden TT 07 GENERAL INFORMATION Size 5 5 x 2 75 x 1 Weight 9 oz Battery 9 volt The TT 07 can detect both series and parallel wiretaps that are attached directly to the on premises telephone line It can also be used to detect hookswitch bypasses that may be installed inside the telephone It can detect series taps of 65 ohms or more and parallel taps with a resistance from 0 ohms to in excess of 60 megohms Listed below are definitions for several terms used in this manual BUG Clandestine listening device HOOKSWITCH BYPASS Modification to the telephone instrument so that the carbon microphone transmitter or dynamic earphone receiver will pick up room sounds and pass them down the phone line to a listening post even with the phone hung up Turns the telephone into a bug PARALLEL TAP Connected across both wires of a pair Usually used to activate a tape recorder DC resistance ranges from 10 to 35 megohms May also be a radio transmitter in which case a separate battery would be
7. CMS 22 COUNTERMEASURES SET INSTRUCTION MANUAL The CMS 22 Countermeasures Set consists of the following instruments and accessories TD 62 Transmitter Detector P 01 Wideband RF Probe P 02 Infrared Probe P 03 Line Driver Probe P 04 Microwave RF Probe TT 07 Telephone Tap Detector Earbuds Various cords adaptors and Padded Carrying Case cl eae ae FINDING BUGS HOME OFFICE Transmitters are frequently concealed in various household or office fixtures The most common are electric sockets or cube taps In this configuration normal AC power is supplied directly to the transmitter which permits permanent installation This means that all lamps and appliances radios TV clock desk calculator etc should be checked carefully Another type is the drop transmitter These are used where quick installation is required Being battery operated they have a finite operating life which requires that they be retrieved for battery replacement or abandoned These transmitters are often pre concealed in objects such as picture frames pens desk sets cigarette lighters and ash trays Body transmitters are battery operated usually with a higher output power than the drop transmitter They are designed to be carried into a target area on a person VEHICLES While voice bugs can be installed in a vehicle probably the most common type is the tracking transmitter bumper beeper Most of these are the burst type which means that RF is transmitte
8. The P CLEAR LED should stay on Release the PTT switch If the PARALLEL ALERT P ALERT LED flashed briefly an additional test is necessary To check for the presence of a capacitive hookswitch bypass press the PTT switch again Hold it down for 5 seconds and release for 10 seconds Push it again for 5 seconds If PALERT LED flashes the second time that indicates a possible capacitive hookswitch bypass 5 Do the same tests as in step 4 with the TEST switch in the TEST 2 position 6 Reconnect the lead to terminal K that you removed in step 3 7 Perform the test in step 4 again Note that the P ALERT LED stays on for 1 to 2 seconds before switching to P CLEAR This is caused by the capacitor connected between terminals K and A of the network 8 Disconnect the Tap Trap reinstall the telephone housing and reconnect the phone to the inside wiring 9 Check the remaining telephones in the same manner following steps 1 8 A POSSIBLE PHONE WIRING PLANS In the Series test if the test was made at point D in the Loop Wiring method the entire loop would be checked with one test But if you only checked at point C the wiring from C to D would not be tested So it is important for you to know the wiring plan before you start testing If you find one tap don t stop looking there may be others A common technique of people planting taps is to place one that can easily be found in the hopes that you won t look for any more after f
9. d in short bursts rather than continuously These transmitters can be powered either by their own battery pack or by the vehicle battery The transmitters powered by the vehicle battery may have a much higher output power and of course a longer useful life The main advantage of the battery pack unit is that it is quicker to attach To check a vehicle for bugs turn the ignition on but don t start the engine Ignition noise will thoroughly confuse the TD 62 Using the P 01 probe slowly sweep the vehicle inside and out be sure to sweep carefully underneath the vehicle Because of the limited brightness of the indicator LEDs it would be better to do this away from direct sunlight if possible Pay particular attention to the meter Brief flashes at the next higher level could indicate a burst type bumper beeper ABOUT THE TD 62 The TD 62 Transmitter Detector is a complex piece of countermeasures test equipment The TD 62 must be used in conjunction with one of the 4 probes described below P 01 Wideband RF Probe up to 2 5 GHz P 02 Infrared Probe Laser Detector P 03 Line Driver Probe Detects hard wired microphones P 04 Microwave RF Probe 2 5 GHz to 6 GHz Description of Functional Buttons Power Button Upper right corner turns the unit on and off If the unit is left on it will automatically shut off in 15 minutes if no other button is pushed this time is adjustable Menu Button To scroll thr
10. d in the Verify mode a rushing noise will be heard in the speaker or earbud A modulated IR beam will also cause signal to increase In addition some type of audio will be heard in the Verify mode Depending on the type of modulation you will hear either baseband audio or some type of tone High speed data above an audio rate will give a rushing sound P 03 LINE DRIVER PROBE SPECIFICATIONS Current Limited to 8 mA maximum Input impedance 8K Ohms Indications Red LED Lights when more than 1 4 volts AC or DC is present on the wire pair under test Green LED When the Line Driver switch is operated this LED glows if 400 uA or more is being drawn by the wire pair under test The more current that is drawn the brighter the LED will grow Controls LINE DRVR OFF This switch applies a voltage to the wire pair under test to turn on voltage activated microphones CAUTION Never push the Line Driver switch on if the Line Driver LED is RED This indicates a voltage present on the wire pair Pushing the line driver while there is a voltage on the line will damage the P 03 and TD 62 Any damage caused in this fashion will not be covered under the product warranty The use of a digital multimeter or other voltage indicating device is highly recommended before connecting the P 03 to any wire pair A B This switch reverses the polarity of the line connections for detecting DC voltages and for reversing the polarity of the
11. inding the first one If you find one tap it would be a good idea to retest the inside wiring to be sure no others are present The hookswitch bypass can also be found by examination of the phone The bypass will consist of one or more resistors capacitors or diodes usually connected to either the hookswitch assembly or network Look for anything in the phone that doesn t fit in or that seems out of place Since phones are relatively inexpensive you may want to replace a suspicious phone with a new one LOCATING WIRETAPS AND WHAT TO DO IF YOU FIND ONE All of the in house wiretaps can be located by close physical inspection of the inside wiring Remember if someone installed it you ll be able to find it Note series taps can be made very small A favorite way to disguise one is to wrap it with tape so it looks like a wire splice or connection If you find a tap then what Your first impulse will probably be to rip it out but stop and think before you do that It may be worthwhile to try to determine who planted it and use the tap to feed them false information If you find one tap don t stop looking It is a common technique to plant one tap that is easy to find in hopes that you will stop looking after you find the first one Another reason to leave the tap in place is so that you can get law enforcement s help in prosecuting whoever placed the illegal tap Most law enforcement departments do not have the manpower to help
12. line driver voltage to aid in detecting polarity sensitive devices THEORY A common eavesdropping attack is the concealed microphone This is simply a microphone hidden in the target area which is connected by wires to a nearby Listening Post L P ora radio transmitter which relays the conversation to the L P To find a concealed microphone during a countermeasures sweep either the mic itself or the wires leading to it must be found This requires that all suspect wires running through or adjacent to the target area be electronically inspected for the presence of room audio GETTING STARTED On the P 03 set the LINE DRVR OFF switch to OFF The A B switch can be in either position Plug the P 03 into the probe jack on the top end of the TD 62 Plug the ear bud into the jack on the top of the TD 62 FINDING MICROPHONES Detection of a concealed microphone and the L P to which it is connected can be a tedious procedure but is not technically difficult Once audio is recovered on a wire pair the wire must be physically traced until both ends are found Keep in mind that wires leading to any loudspeaker in the target area i e part of an intercom or speaker system can be exploited by an eavesdropper The reason is that loudspeakers can act just like microphones Use the following procedures to search for hidden microphones TARGET SIDE i MONITOR SIDE ROOM _ a AUDIO j aS m Si E i MINIATURE MICROPHONE
13. op two switches on the Tap Trap so that left side of the switches are down and connect the unit to the inside wiring at any convenient point If your building does not use modular jacks it will be necessary to connect the Tap Trap using the supplied coupler and cord with alligator clips be sure to connect red to red and green to green 4 Push and hold down the PUSH TO TEST PTT button for at least 5 seconds The PARALLEL CLEAR P CLEAR LED should stay on Release the PTT button If the P ALERT LED flashed briefly an additional test is necessary Here s why 100 feet of inside wiring has about 002 uF of stray capacitance between any two wires in the cable This stray capacitance causes the P ALERT to flash To check for the presence of a capacitively coupled parallel wiretap press the PTT switch again Hold it down for about 5 seconds and release it for 10 seconds Push it again for about 5 seconds If the P ALERT flashes the second time that indicates a possible capacititely coupled parallel wiretap 5 Do the same tests as 4 above with the TEST switch in the TEST 2 position SERIES TAP CHECK 1 At the protector block location short the red and green inside wires together using the jumper cord with alligator clips at each end 2 Set the Tap Trap switches TEST switch down on the left side and the SERIES switch down on the right side connect the Tap Trap to a phone connection point 3 At each connection point push and hold do
14. or pulse frequency modulated sources the technician can actually listen and determine whether the beam is carrying voice transmissions or other intelligence Light beams carrying room audio can be very narrow They can shoot through windows and reflect off glass metallic and other bright surfaces This can be readily demonstrated with a TV remote control infrared device Try pointing it at different surfaces around the room and notice how the TV can be controlled by reflections from pictures and windows Narrow light beams are very directional line of sight a point the countermeasures technician should keep in mind DETECTION Insert the P 02 probe into the center jack on the TD 62 Turn on theTD 62 Any number of tests can be made to verify that the unit is working In the Detect mode when the probe is pointed at incandescent or fluorescent lights the meter signal will increase and the clicking rate will also increase In the Verify mode a hum or buzzing sound will be heard When an IR signal is detected the red signal LED on the IR probe will light the bar graph in the display of the TD 62 will grow in size and the clicking rate will increase At this time slowly sweep the probe from side to side to get a bearing on the transmitter s direction When sweeping for IR transmitters pay particular attention to window openings remember that light travels in a straight line An unmodulated IR beam will cause the signal to increase an
15. ough the menu options continue to push the menu button within 5 seconds Use the up or down arrows to change the selection First Push This selection allows the user to change from the Detect mode to the Verify mode The Detect mode is used to locate transmitters and the Verify mode is used to determine if audio is being transmitted Second Push This will allow you to change from high sensitivity to low sensitivity by using the up and down arrows This will aide in locating bugs Once you have a strong signal switch to low sensitivity to help pinpoint the location of the transmitter Third Push This will adjust the brightness of the backlight by using the up and down arrows Fourth Push This will adjust the contrast of the display by using the up and down arrows Fifth Push This allows you to adjust the time set for the auto off feature set to 15 minutes at the factory however it is adjustable by using the up and down arrows Sixth Push Shows remaining battery voltage Arrow Buttons The use of these buttons by themselves will allow the user to adjust the volume of the TD 62 The battery can be accessed through the sliding cover on the bottom end DO NOT disconnect the battery by pulling against the wires Damage caused in this manner will not be covered by the warranty The battery should only be replaced with a 9V DC alkaline or equivalent battery The top of the unit has two jacks
16. required for powering the transmitter SERIES TAP Usually a radio transmitter Obtains power from the telephone line to which it is attached Itis installed in series in line with one wire Generally has a DC resistance of 70 to 300 ohms And although rare it can also be used to activate a tape recorder WIRETAP Clandestine interception of a telephone conversation Operates when the telephone is in use We recommend that you perform the tests in the order given in the manual While the Tests can be done in any order the manual lays out the most efficient procedure USING THE TT 07 The battery is located on the bottom of the unit Slide the battery cover to the side to access or change the battery Replace only with a 9 volt battery mW ARNING WARNING WARNING BEFORE PERFORMING ANY PHONE WIRING TEST YOU MUST DISCONNECT ALL WIRING FROM THE PROTECTOR BLOCK PHONE CO INTERFACE NEVER PERFORM ANY TESTING WHILE WIRING IS CONNECTED TO THE PHONE COMPANY S EQUIPMENT Parallel Tap Test 1 Disconnect the inside wiring at the protector block or phone company interface The protector block can be located either inside or outside the building and is the point where your wiring physically connects to the phone companies wiring Make a note of the wire colors and connections so you can reconnect them properly once you are finished testing 2 Disconnect all telephones answering machines computers etc 3 Position the t
17. wn the PTT switch for at least 5 seconds The SERIES CLEARLED should stay on The SERIES ALERT LED may flash briefly this is of no consequence If the SERIES ALERT LED stays on this means the loop resistance is over 60 ohms and is an indication of a series tap 4 Repeat step 3 with TEST switch in TEST 2 position 5 Repeat steps 3 and 4 at each inside connection point 6 Disconnect the Tap Trap and remove the shorting jumper that you connected to the inside wiring in Step 1 7 Reconnect the inside wiring to the protector block HOOKSWITCH BYPASS TEST Telephones with modular plugs can be connected to the Tap Trap using the coupler provided Phones without modular plugs can be connected using the coupler and cord with alligator clips Connect red red and green green Most in phone taps such as the hookswitch bypass can easily be located with a careful examination of the phone Look for anything out of place such as splices or anything that does not have the factory look 1 Remove the cover from the telephone by loosening the screws on the bottom plate 2 Connect the Tap Trap to the free end of the telephone cord and position the top two switches on the Tap Trap so that left side of the switches are down 3 Locate the wire connected to the network terminal K in the telephone and temporarily remove it 4 Be sure the hookswitch is held down depressed and push and hold down the Tap Trap PTT switch for at least 5 seconds
Download Pdf Manuals
Related Search
Related Contents
manual técnico del usuario del nuevo sistema de Manual de Usuario Kalley K dossier technique lyon - Fédération Française de Gymnastique 機械を譲渡または貸与する事業者の皆さまへ Storm Lighting Enclosures EzLIB API User Manual 稚 内 市 (仮称)生ごみ中間処理施設整備・運営事業 事業契約書 平成21 Copyright © All rights reserved.
Failed to retrieve file