Home
        Scorpion 4120
         Contents
1.    4120  6020  amp  8020       Thank you for purchasing a  Quality Micron Security Alarm Controller   Micron product is manufactured  to exacting quality standards    We understand the importance of designing  products that are reliable and easy to use   You can rest secure knowing we have thought  of everything to ensure your  complete peace of mind     micron security products             contents    The Icon LCD Keypad    Padlock Symbol syans 404  92 19 eue Rep I ERR DE RE aes 2  PowerLead Symbol           0 00  eae 2  System Fault Symbol  iessen re 20 0 0  c cee eae 2  Bell Symbol    2 ahi ihe ea eid eC e BA oe ea N 2  Moon Symbol arera evan been xerox ary AR XE ee eae eed 2  Area Identifier Symbol    EE eee tea eR x ea es 3  Zone Indicators    ieee is sea kd us x RR 3  User Codes  Arming the System s  eserirrisadsair aast eh 4  Disarming theSystem       crersrsek ast itr r eese 5  Using Quick Armi   2    tee 5  To Armthe System and ExcludeaZone s             0 00 eee eee 5  Adding  Changing or Deleting a User Code                   04  5  Night Arming Options  To Arm the System and ExcludeaZone s             0 0  eee ee eee 6  Arming with Preset Night Zones    0 0 0 0    00 cece ee 6  NiteWaton ot cee tha bets Oe ee ERU RD wae ba eye ed Ne ree 7  Telephone Arming and Disarming  Answer Phone Defeat            0 000 cee nee 8  Hold Down Commands  Setting the Real Time Clock Time                200 eee eae 9  SettingtheAutoArmingTime                  202 eee e eee eee 9  Do
2.    For partitioned systems  8020 only  entering 1    will arm Area A and entering 2   will arm Area B     Quick Arming Scorpion  1         To Arm the System and Exclude a Zone s     Enter a valid user code then    all Zone icon s light  followed by the zone  number s  to be excluded  those zone icon s turn off   then press       Example  to arm the system with zones 4 and 5 excluded press   DDOD then  x  then  4   5  then        Adding  Changing or Deleting a User Code   Enter a valid master user code  press keys 1 3 together then enter a new  user code then enter   then the user identifier  1 to 24   Repeat the  procedure for adding other new user codes  To delete user codes  Enter a  valid master user code  press keys 1 3 then enter  then the user identifier     Example  To change the master user code from 1234 to 1912 press the  following sequence     ODOH ter O   tte CO  2 CO  H then CO             night arming options       To Arm the System and Exclude a Zone s     Enter a valid user code then    all Zone icon s light  followed by the zone  number s  to be excluded  those zone icon s turn off   then press       Example  to arm the system with zones 4 and 5 excluded press     ODODO nen   then 4   5  then H     Arming with Preset Nite Zones Options    You will need to discuss with your installer the configuration of your system s  night arming zones  as this is an installer selectable option  Itis importantthat  your installer completely familiarises you with how Scorpion
3.   terminate here with the  STAR  key  BEEP BEEP    oom        te CO 8   0 00  te  8  CO  D  9 0  9 09  te  8  2  8   9     G0 CO 6   0 090909                             Selecting this option forces all dialler transmissions to be signalled in siren  tone format  The alarm will call each number in turn and transmit a siren sound  followed by a sequence of beeps and a short pause after which the entire  sequence is repeated  The number of beeps sent correspond to the zone  number that has been activated  If the called party presses the    Star  key on  the telephone keypad during the pause  the call is terminated and no further  calls are made  If the Star key is not heard by the dialler within 60 seconds  the  call is terminated and Scorpion dials the next programmed number     system options       Smoke Sensor Reset    Some latching style smoke sensors connected to alarm controls  once  activated  must be reset through the alarm keypad  Check with your installer if  this type of sensor is used in your system  To reset a latching style smoke  sensor enter 7   at the keypad  Reset all smoke alarm activations by entering  a valid user code     Chime Mode    Your installer must program zones  which will be active in chime mode  If this  feature is programmed  each time a chime mode sensor is activated while the  system is disarmed  and chime mode is turned on  the keypad beeps for  approximately five seconds  In this mode  Scorpion can act as a door or area  minder when the alar
4.  arms and alarms  in the two Night Arming modes     Scorpion has two night arming options  Night arming offers the user perimeter  protection with the freedom to move freely within the areas that would normally  be protected by the alarm control    The systems can be night armed with either instant zones  that is zones that  arm instantly and alarm instantly  or with delayed zones  zones that arm with a  delay or alarm with a delay on entry  This method of night arming with delay is  used where the system is to be armed at night with the occupants at home  but  a member of the family is yet to arrive home and must be able to enter and  disarm the alarm system before re arming in Instant Mode     To night arm a non partitioned system with instant arming and alarming  enter 8 1      To night arm a non partitioned system with delayed arming and alarming  enter 9 1     The second area of a partitioned system may be night armed  using 82  and 92     To Instant Night Arm Press For Delayed Arming Press    OO OO             If night arming with delayed arming and alarming  9 1   or 9 2    is selected   the alarm control allows an exit period before arming  however the keypad  beeper exit alert is NOT sounded  except where a zone is not secure  possible  door window open or sensor activated   At the end of the exit period the  keypad beeps three times  Violating a night arm zone starts the entry pre alert  keypad beeper before sounding an alarm  To deactivate the system during the  pr
5. E ee aa  Installation Date EE ee ee ee ee ee ee ee ee ee ee ee ee ee  Warranty EXpIFGS      esse ME eed ded tds RE EE ee ees    zone descriptions   Zone E ZONE DERE RE ee Ee  ZONE  me n RE ZONE EE  Zone 3 ee Zone T EE  ZONE EE ES EE ected ZONG O se EE EE ED EE    entry and exit times   Entry Delay    Exit Delay          ss  Alternate Entry Delay                             Siren Delay       AnaL KA EER OE ET N  F2 AE EE OE N OE EE OE N EE N  FI Key se is ie N ED ER cC RE EE            micron  security products    
6. e alert  enter a valid user code then       Nitewatch  if connected   To night arm the system  simply press the ARM  key on the Nitewatch station  To disarm the  system  press the ARM key again    Note  If activation occurs and the sirens are  activated  the system can NOT be disarmed NITEWATCH  from the Nitewatch station  Once activated and    alarmed the system can only be disarmed by EMERGENCY    entering a valid user code then   at the keypad     UNSAFE    O       If the UNSAFE icon is illuminated  this indicates an unsecured zone  This  should be secured before arming the system safely in Night mode  The  ARMED icon illuminates when the system is armed     Night arming from Nitewatch may be either delayed perimeter arming with pre   alerts or instant perimeter arming with instant alarms  To arm the system in     delayed    mode  press the ARM button momentarily  Nitewatch beeps once  and the ARMED led starts flashing    At the end of the programmed exit delay  Nitewatch beeps three times and the  ARMED led locks on  The control is now armed and all night arming zones will  sound a pre alert for the programmed entry delay before activation     To arm the system in instant mode  press the ARM key for 2 seconds   Nitewatch beeps and the ARMED led lights  The control is now armed and will  activate instantly if any night arming zone is violated     The Nitewatch emergency panic key may be activated at any time by using  two fingers to press both ends of the EMERGENCY key sim
7. enced  If  the activation or malfunction is repeated  Scorpion will count the number of  activations until the shutdown count has been reached and then shut down the  zone  thus preventing further activations  The user should immediately  contact their alarm service or installation company and report the fault  The  system should NOT be armed as this will re set the  shutdown  counter and  allow further activations     partitioning        Scorpion 8020 only     You will need to discuss your requirements for alarm partitioning with your  installer  as this is an installer selectable option  Alarm partitioning enables  Scorpion 8020 to be split into two discrete alarm systems  For example  you  may have a sub dwelling or work shed attached to a main dwelling  partitioned  as a separate alarm system  Partitioned systems offer all the functionality of a  non partitioned system     13             User User   Master Arm Phone   Arm Area   Report to   Can Exclude  Number   Initials   Code Only Arm AorB   Station Zones    1       2       3                               20       21               mms  Ce   N         22    23          24                      14                IMPORTANT  This Alarm System Must be Tested Weekly to maintain System Integrity  15               installation notes    Installation Company EE e ee eenee teeta en eeeeneeteneeceneaeeteneeseneeeeeeneeteneeeee  Technician             Sesen eS ees ck sere RE EDE eek Aine eet ends ies olay tele dia eet  Phone Number E
8. feat   To defeat the answer phone  call the system phone number  When the answer  phone or fax answers the call hang up and call again within 60 seconds   Scorpion will answer the call on the first ring thus defeating other devices  Wait  forthe 2 beep acknowledge and arm disarm the system as detailed above              hold down commands       To use a hold down command the function key  keypad digit  must be  pressed and held down until a second key beep is heard  Note that hold  down commands will ONLY function when the alarm control is fully disarmed   The following hold down commands are available     Setting the Real Time Clock Time    It is advisable but not mandatory to set the system real time clock  Check with  your installer if the clock has been set  The clock MUST be set if the auto   arming feature is used  Clock time is in 24 hour format     To set the clock proceed as follows  Press and hold down key 6 until a second  key beep is heard then enter a master user code then   then the time in 24  hour format then       Example  Setting the alarm system clock to 2 45 pm     BEEP BEEP    pow        ther CO 2  5   0 hen OOOOH    Settingthe Auto Arming Time    Scorpion may be programmed to auto arm at a pre set time each day  To  access this feature an auto arming time must be programmed using the Hold  Down 7 command  Press and hold down key 7 until    second key beep is  heard then enter a master user code then   then the time to arm in 24 hour  formatthen       Exa
9. m system is disarmed  Chime mode is temporarily  disabled each time the alarm system is armed  To turn chime mode on and off  press 7 1 then    For Scorpion 8020  where the system has been partitioned   press 7 1  for AreaA and 7 2  for Area B     Two Key Panic  If this function has been programmed in the Scorpion by your installer it may    be activated by pressing the keypad   and   keys simultaneously  All internal  and external alarms will activate  A panic activation may be cancelled by  entering any valid user code then       In Panic Situations Press Ge    H    11             Two Key Medical Alert    If this function has been programmed in the Scorpion by your installer it may  be activated by pressing keys 4 and 6 simultaneously on the keypad  A  medical activation may be cancelled by entering any valid user code then       For Medical Alert Press  4     6     Two Key Fire Alert    If this function has been programmed in the Scorpion by your installer it may  be activated by pressing keys 1 and 3 simultaneously on the keypad  Fire  activation may be cancelled by entering any valid user code then       For Fire Alert Press  1     3     12             24 hour zones    If your installer has fitted a smoke detector s  to your system it will be  connected to a 24 hour zone  thus ensuring that this device is always active   In the event of an activation or detector malfunction your alarm system will  activate  Enter a valid user code at the keypad and all sirens will be sil
10. mestic Dialling    34226044203 ha be ee he RR FER ed ees 10  System Options  Smoke Sensor Reset   202 6600 eee ees 11  CHIME Mode  i estes OE dee ed ed ie RE ed 11  Two Key Pani      coeli ee xay xxx edd eee 3x 11  Medical Alen    ica ies ates ee stad xe Te ORE GE ctt Dee BER ee Ee 12  FireAlert si be RD ER es ces Ge vA a RR EUR ER DAE AAS 12  24HourZoneS         EE SE eee eee 13  Partitloning  ub seis vs Sees xi Ru RES Y afe a inc S 13             the icon LCD keypad       The Scorpion communicates system status through the keypad beeper and  icon symbols  The LCD keypad gives full visual indication of the status of your  alarm system  The keypad has five graphic symbols  an area identifier and  zone indicators  During an arming cycle the beeper will sound for the entire  exit time  This is the exit warning time  Scorpion will arm at the expiry of this  period  On entry  the beeper sounds for the programmed entry period  If a valid  user code is entered to disarm the system  the beeper emits two short tones     An incorrect entry is signalled by one long tone     Padlock Symbol    The padlock symbol is unlocked when the  system is disarmed and locked when away  armed or night armed     Power Lead Symbol   The power lead symbol is on solid when  mains power is present and flashes  together  with the system fault symbol  when there has  been a mains power failure     System Fault Symbol    The system fault symbolis visible and flashing  when there has been a system fault condi
11. mple  Setting the auto arming time to 5 30 pm  BEEP BEEP    pow     ther CO Q2   8   0 6  ve OOOOH             If a valid auto arming time has been entered  the keypad will sound three  beeps every six seconds for the installer programmed pre alert time before  auto arming  At the end of the pre alert time the panel starts counting down  the exit delay and sounds the leave now warning beeper  then arms all zones   During the pre alert  entering any key at the keypad will abort the auto arming  cycle  Once the alarm has started the exit timer and warning beeper  a valid  user code is required to abort the arming cycle     Entering an invalid auto arm time  eg  2500  disables this function  This is the  factory default setting    Note  To enable auto arming it is also necessary to program the correct time  into Scorpion s real time clock     Domestic Dialling    The installer must enable this feature during installation  Scorpion may be  programmed by the end user to call one or more phone numbers and report  alarms  The called number s  may be changed at will by entering the following  sequence atthe keypad     Press and hold down key 8 until    second key beep is heard then enter a  master user code then   then the telephone number s  then    star   Use the    key between numbers if more than one number is to be called  Note that the  star key ends this sequence    Example  Programming the alarm system to call 8197654 then 8256631 then  5292048    If only one number is called
12. r code 15 is a night lock code for a 4120  amp  6020 system  If the 4120  amp  6020  is armed with user code 15  only this user code can disarm the system     Arming the System    Enter a valid two  three or four digit user code then       ODOH tte       If all zones are clear  the keypad sounds a repeating sequence of three short  beeps for the duration of the exit delay and the padlock icon locks  The zone  icons for all zones that are arming are also turned on  At the end of the exit  delay the zone icons extinguish and the system is now armed     If a zone fault or potential alarm condition exists and the user attempts to arm  the system  the icon s  for those zone s  flash and are accompanied by a  repeating sequence of two long beeps  This indicates that one or more of the  zones are faulty or not secured  The panel should be disarmed  the problem  located  possible open door or window  and the system re armed              Disarming the System  Follow the same sequence as for arming  enter a valid two  three or four digit    user code then     ODOH tren       The keypad will beep twice and the padlock will unlock  Flashing icon s  indicates that one or more zones have been alarmed  The zone Icons for any  zones  which have alarmed will flash until the next arming cycle  Note the  zone number s  and notify your installer  or security monitoring company     Using Quick arm    If your installer has programmed the quick arm option you can arm the  system by entering 1 then 
13. tion  or system panic activation     Bell Symbol    The bell symbol is visible and active when an  alarm condition has occurred or a system  panic activated     Moon Symbol    The moon symbol will be visible when the  system is night armed     ID  Ta    ARMED DISARMED    8  N  A  C             Area Identifier Symbol    The area identifier symbol is the four segment box at the lower right hand side  of the LCD display  This symbol shows  the area s  that is armed or night armed   In non partitioned systems  Area A is  only displayed        Zone Indicators    The zone indicators are shown as numbers 1 through 5  4120   6  6020  or 8   8020  on the top line of the LCD display  These zone numbers show zones  that are arming  alarmed zones and also    identify the system fault conditions   a  2 n na    When the system is arming  the LCD will   display all programmed zones  the padlock in locked mode and the area  identifier showing the area s  that is arming  The keypad will sound the Exit  warning  If any zone is not secure  that zone number will flash and the keypad  will sound a slower beep  The alarm should be disarmed  the problem  identified and the system re armed     When an alarm occurs  the LCD will display the flashing zone numbers that  generated the alarm condition  the area identifier flashing the area of the  alarmed zones  eg  A   the padlock oscillating between locked and unlocked  and the bell symbol in ringing mode  After disarming the system the alarmed  zones 
14. ultaneously  The  back light intensity of these keys may be adjusted up and down by pressing the  right side of the emergency key to increase the brightness and the left side to  decrease brightness  The Nitewatch Auto Dim feature will automatically dim  the Unsafe and Armed icons 60 seconds afterthe ARM key is pressed              telephone arming  amp  disarming       Scorpion may be armed  and disarmed if programmed  by any touch tone  phone using a valid user code  This feature must be pre enabled by the  installer     Arming   From a touch tone phone call the system phone number  The  installer will have programmed the alarm system to answer after 2 to 15 rings   When the system answers the incoming call there is a short delay while  Scorpion listens for a remote computer modem  The user then hears 2 short  beeps  enter a valid remote arming user code at the telephone keypad  then  the   key  If the access has been successful the user hears the    leave now   warning beeper indicating thatthe system has been successfully armed  Hang  upthe phone     Disarming   If programmed  Scorpion can disarm the system remotely by  using the same method as in arming  If the system has been successfully  disarmed the userhears 3 beeps     Answer Phone Defeat    If the alarm system phone line is shared with an answer phone or fax and it is  proposed to use the remote arm disarm feature it will be necessary to advise  your installer so that Scorpion may be programmed for answer phone de
15. will continue to flash until the next arming cycle     If the system fault icon is flashing  the alarm condition may have been caused  by a miscellaneous alarm condition  Press 89 then   on the LCD keypad to  display system faults  The zone numbers display one or more of these system  faults          Zone Indicator   System Fault   Zone 1 Nite Watch Panic or Code Pad Panic  Fire  amp  Medical Activated  Zone 2 Back Up Battery is Low or Faulty   Zone 3 AC Mains Power has Failed   Zone 4 Dialler Communication Failure   Zone 5 Faulty or Disconnected Phone Line   Zone 6 Power Overload on 12 vdc   Zone 7 Siren Output Fault                   user codes    Scorpion is capable of storing up to twenty four user codes  Each user code  may be two to four digits in length     User code 1 is factory set as a master user code 1234 and should be changed  to your own selection  This user code can also be used to program the  remaining user codes  Your installer will need to assign the functions of each  additional user code when your system is installed  For example you may  require user code 18 to be used by a domestic helper to arm but not disarm the  system  This restriction on code 18 will need to be pre set by the installer  The  code may be entered at a later time using the master code  Use the user code  attributes table in the rear of this user manual to record the functions for each  code     User code 15 is reserved as a disarm all areas  code for a partitioned 8020  system     Use
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Preamplificador de micro de válvulas de un sólo canal    Centrale des Moins Mobiles via Internet Manuel d`utilisation  LET39C800HF Téléviseur LCD LED 99 cm Full HD      Contrat de location – Conditions générales (AMVB)  UVALOC 400  SA-VS300H  Speco Technologies WDR-R3 User's Manual    Copyright © All rights reserved. 