Contents

1. and inputs switched to monitoring off OK system OK and all the inputs that are set to monitoring on is OK Too low outdoor temperature Too high outdoor temperature Outdoor temperature input shortcircuit Broken cable by outdoor temperature input 1 Alarm caused by an external unit 2 alarm yet not cleared at Dr Bell speech computer clears within one minute to be ignored Alarm by main power monitoring relay 1 13 Alarm by main power monitoring relay 14 Alarm by on or more inputs See next table to detect fault INPUT ALARM CODE 2 INPUT ALARM CODE Pres RETURN and then ALARM SETTINGS Press any of the keys 1 10 to see the code for the this input INPUT ALARM CODE MEANING 1 Monitoring switched off for this input 0 OK Monitoring on for this input and no fault detected 1 Too low temperature 2 Too high temperature High outdoor temperature situation High temperature threshold exceeded code 2 but outdoor temperature addition not exceeded No siren sounds 4 Maximum fluctuation within 10 minutes exceeded 5 Temperature input short circuit 6 Broken cable by temperature input Lis 0 3 Restart When faults have been corrected press START STOP If OK the display will show 0 and the lamp ALARM will be on constantly
2. 2 1 3 1 4 2 1 DrSherlock351 GB manual Klima Design A S 8 2008 Keyboard In this manual the keys are referred to in bold typesetting The keys labelled with numbers from 1 10 correspond to the 10 temperature sensor inputs The key which is currently active e g the corresponding value is displayed has the light on SHIFT has a special function When activated you may press another key and both keys have the light on accessing special registers for use during installation Please read special installation papers The key RETURN is used to return to normal displaying of temperatures The key START STOP is used to stop the siren and to toggle the inputs 1 10 on and off Changing values To change a value ARROW UP DOWN If you hold the key down changing will speed up after 2 sec Values cannot be change beyond certain limits e g or 40 0 C where the system would not be able to function Lock keyboard Its posible to lock the keyboard to prevent non authorized people from operating Unlock by pressing SHIFT and then both ARROW keys at the same time When locking mode is activated the locking will lock automatically after the specified time Press SHIFT and then MIN MAX Change the value from 0 off to a value between 1 10 to activate locking mode with a triggering from 1 10 minutes Time date and year Time date and year is used to stamp the logged data temperatures etc with date and
3. 5 0 Speech computer Please also refer to Dr Bell OPERATION INSTRUCTIONS The Dr Bell speech computer and Dr Sherlock is working together by means of a RS485 communication network Key pressed Function performed RETURN Stops talking START Current alarm causes will be acknowledged and Dr Bell will STOP announce alarm cause error type and station number name START STOP Disables alarm supervision for 60 minutes When the ARROW DOWN intermission comes to an end alarm supervision is automatically engaged Request value station no register no E g 1 1 requests current temperature from station 1 Remote control station no register no value E g 1 3 280 Changes maximum threshold temperature for station 1 to 28 0 C Note that decimal digit must be entered since a telephone don t have a decimal point on the keypad In case a negative value is needed enter a 0 a the first digit Register no for the 10 inputs Digits Description Temperature 2 Minimum threshold temperature Maximum threshold temperature 4 1 High outdoor temperature compensation addition Maximum fluctuation within 10 minutes 1 Offset value for sensor Register no for SYSTEM Digits Description Outdoor temperature Minimum threshold Outdoor temperature Maximum threshold Outdoor temperature N 4 2 TIME 5 2 DATE 6 Year Supply voltage norm
4. Dr Sherlock TEMPERATURE MONITOR Dr Sherlock TEMPERATUR OVERVAGNING USER MANUAL VER 3 51 DrSherlock351 GB manual Klima Design A S 8 maj 2008 1 Table of contents 1 1 Keyboard oat inane end 1 2 Changing VAG de enn tee de 1 3 Lock eV de a gt arn arate ease 1 4 Time ANG aretada ae 2 1 Reading of temperatures 2 2 High and low Vales dd WAC LESS SURGES oie Bee ews 4 0 D ta ONG eens 4 1 Displaying of saved 4 5 0 Speech 6 0 Alarm threshold values 6 1 Outdoor temperature ne AGO em ee at 6 2 Maximum fluctuation within 10 minutes 6 3 Monitoring of main power supply 0 0 0 0 cece cence eee eee 6 4 Start st p MONON E esere ta reiasa tee xed 6 5 When salary occurs Stop Sirei cancer 6 7 Testing 5544498605 x ered dete Rd DrSherlock351 GB manual Klima Design A S 8 2008 1 1 1
5. LARM SETTINGS code and then 3 times Factory setting is 2 0 C but you may increase it to 4 5 0 C to make it more efficient fewer alarm by high outdoor temperatures Pressing START STOP and OUTDOOR may toggle HOTCA function on and off for all inputs 1 10 HOTCA is on when OUTDOOR light is on and off when light is off 6 2 Maximum fluctuation within 10 minutes To alter the value maximum fluctuation within 10 minutes press ALARM SETTINGS code and then 4 times more Factory setting is 10 0 C but you may decrease it to 1 0 2 0 C to make it more sensitive It is off when value is set to 0 0 C DrSherlock351 GB manual Klima Design A S 8 2008 6 6 3 Monitoring of main power supply Dr Sherlock monitors its own 12 VDC supply and the accumulator If you want to monitor the supply of other equipment then use a main power monitoring relay which connects to a special input see installation papers Ifa fault occurs at the main power monitoring relay input the system alarm code will be 13 This alarm cannot be suspended removed alone but only by switching monitoring of all inputs to off by pressing START STOP in 2 sec the display will show 1 6 4 Start stop monitoring The monitoring of the inputs may be switched off and on individually 1 Press START STOP 2 You may now toggle alarm monitoring off and by pressing either of the inputs 1 10 Monitoring on is by light on and monit
6. ally 13 8 V Siren activation minutes 14 1 Offset value for outdoor temperature sensor DrSherlock351 GB manual Klima Design A S 8 2008 5 6 0 Alarm threshold values Press RETURN Press ALARM SETTINGS Alarm code will be displayed for the active input 1 10 Press once more to show minimum temperature threshold e g 16 C Alarm code 1 indicates that this threshold has been exceeded There are 4 threshold values Press key Alarm Factory ALARM code if Indication by lamp setting SETTINGS exceeded Threshold minimum temperature threshold MIN MAX on maximum temperature threshold MIN MAX flashes 1 time 2 times 2 4 times 3 times 3 High outdoor temperature OUTDOOR on compensation addition HOTCA There will be no alarm as long as temperature is below outdoor temperature HOTCA 4 Maximum fluctuation within 10 minutes Note Feel free to access the threshold values for other inputs by pressing the key corresponding 1 10 6 1 Outdoor temperature The outdoor temperature is displayed by pressing OUTDOOR The outdoor temperature has minimum and maximum threshold values to be engaged in the same way as the other inputs 1 10 Factory setting is 40 0 C and 40 0 C meaning not engaged High outdoor temperature compensation addition HOTCA There will be no alarm siren as long as temperature is below outdoor temperature HOTCA But alarm code will 3 To alter the value press A
7. hour When altered the stamping will only affect data from this moment Reading of temperatures Press RETURN and one of the keys 1 10 to display the present temperature measuring at this input Temperature measuring goes from 40 0 C and 40 0 C 2 2 Note 4 0 4 1 Note DrSherlock351 GB manual Klima Design A S 8 2008 High and low values Press MIN MAX once to show lowest value this date Press MIN MAX once more to show highest value this date You may now press TIME to se the corresponding hour for the measurement The lamp HISTORIC flashes to indicate that the values displayed are not present Press RETURN to return to normal displaying Data logging Every 10 minutes Dr Sherlock saves in memory the measured values at the ten temperature inputs plus outdoor temperature together with a time stamp By alarm situation and when it changes back to 0 OK it saves too Displaying of saved data RETURN should be engaged and then choose one of the inputs 1 10 Press ARROW DOWN to go back in time one step at a time You may go forward by pressing ARROW UP The lamp HISTORIC flashes to indicate that the values displayed are not present readings When the lamp HISTORIC flashes you may choose other inputs 1 10 to display corresponding values at this point Press TIME DATE to display corresponding time Press ALARM to display corresponding alarm code Press RETURN to return to normal displaying
8. oring off is by light off Note Switch monitoring of all inputs and the complete system to off may be done by pressing START STOP in 2 sec the display will show 1 To activate system again press START STOP Note It may be convienient to leave Dr Sherlock in START STOP mode showing status of the 10 inputs e g Light on Flashing light Alarm Light off OFF 6 5 When alarm occurs stop siren e Siren will sound for a limited time 1 10 minutes see installation papers Alarm situation shows by flashing lamp ALARM PRESS Function START STOP Siren stops sounding Inputs that are in alarm condition shows flashing lamp Correct the faults by inputs in alarm condition and press START STOP again the display should show 0 Or you may stop monitoring at the faulty inputs se paragraph 6 4 6 7 Testing accumulator To make sure the accumulator is OK Dr Sherlock may be setup to perform a 10 minutes test from 8 00 to 8 10 Alarm codes If the voltages drops below 11 7 a warning will occur and alarm code will be set to 9 If the voltages drops below 11 5 an alarm situation will occur and alarm code will be set to 10 and the test will stop The lamp in the key TIME will flash as long as the test is going on DrSherlock351 GB manual Klima Design A S 8 2008 7 BY ALARM 1 Press START STOP Siren stops Notice the code in the display SYSTEM ALARM MEANING CODE Complete system