1. Type Series to Q Series Handbook Intelligent Function Modules L NA 08220ENG issued by Mitsubishi Electric Precautions for wiring Set the pins of each channel Gl to CE according to the input The default settings for all channels are voltage input side Voltage input set to side Current input set to JJ side Wiring to connect the AG terminal TB5 TB6 TB15 TB16 on the A1S68AD side is not required because there is no AG terminal on the Q68AD G side Note however that leaving the AG terminal connected will not cause a problem because the wire is not connected inside of the Conversion Adapter cHe TBT CHT cpe B1 CHT i TB2 CH2 T TB2 CH2 TB3 CHT TB3 CHT curi TB4 CH2 c gt a S Ter CH 2 TB5 AG z TB5 AG NotrequiedK TB6 AG TB6 AG CH3 TB7 CH3 che TB7 CH3 F TB8 CHa T TB8 CH4 al TB9 CH3 ai TB9 CH3 TB10 CH4 g TB10 CHa cus gt e Bit CHS chs gt TBT CHB F TB12 C
2. z Zz O e Cover E E N 2 Make sure to set the setting pins H short bar before Ho 4H installation an Setting pin About the protective wrap _ he protective wrap It is used to protect your hands from touching the conductive part in the pin setting process 1 Peel it off after finishing the settings 2 Make sure to peel it off before installing a MELSEC AnS Series terminal block 5 2 How to set the setting pins Set the voltage input side or current input i side for each channel using the short bar The short bar can be installed from any direction F Voltage input Channel Current input Factory setting E o N a Q o CH3 5 n Q o CH4 a E oa a Q o chr E o Q o CH8 ES a EE lkl Notice Incorrectly setting the setting pins will cause a failure and mal correctly Set the voltage during No short bar installed current input Set the current during voltage input Short circuit between and V Short circuit between channels 5 3 Procedure Set the setting pins short bar as necessary 1 Set the pins in order from one side Gi or Giz to avoid the incorrect setting 2 Insert the short bar all the way into the setting pins in place till it can not be moved Open the cover Setting pin
3. Mitsubishi General Purpose Renewal Tool Programmable Controller Conversion Adapter Model ERNT ASQT68AD G User s Manual sa MITSUBISHI ELECTRIC ENGINEERING COMPANY LIMITED HEAD OFFICE Hulic KUDAN BLDG 1 13 5 KUDANKITA CHIYODA KU TOKYO 102 0073 JAPAN NAGOYA ENGINEERING OFFICE 139 SHIMOYASHIKICHO SHIMOYASHIKI KASUGAI AICHI 486 0906 JAPAN SAFETY PRECAUTIONS Always read these precautions prior to use Before using this product please read this manual carefully and pay full attention to safety to ensure that the product is used correctly The precautions presented in this manual are concerned with this product only For Programmable Controller system safety precautions refer to the user s manual of the MELSEC Q series CPU module to be used In this manual the safety precautions are ranked as WARNING and CAUTION enw BBM BM BM BM BM BM BE BM BM EB BM eB eB ee eB eS n S l Indicates that incorrect handling may cause hazardous conditions l l N WARNING resulting in death or severe injury l l A CAUTION Indicates that incorrect handling may cause hazardous conditions l resulting in medium or minor injury and or property damage l Note that failure to observe the A CAUTION level instructions may lead to a serious consequence according to the circumstances Always follow the precautions of both levels because they are important to personal safety Please keep this manual in
4. Short bar Make sure they have been set Hold the protective wrap with its rear side towards correctly and close the cover the right and peel it off towards yourself before installing a MELSEC AnS Series terminal block Protective wrap 6 Part Names and Installation Method Installation with the Base Adapter Base Adapter To the control panel MELSEC Q Series B Unit ase Uni MELSEC AnS Series terminal block MELSEC AnS Series terminal block cover supplied with Conversion Adapter MELSEC Q Series Module Fixture has been installed to the Conversion Adapter we MELSEC AnS Series terminal block installation screw M4 Fixture installation screw M3 x 8 supplied with Conversion Adapter Conversion Adapter installation screw M2 6 x 20 Conversion Adapter Make sure to set the setting pins before installation Installation with the DIN rail DIN rail MELSEC Q Series Conversion Adapter DIN rail mounting bracket right Base Unit MELSEC AnS Series terminal block MELSEC AnS Series terminal block cover supplied with Conversion Adapter x 7 MELSEC Q Series Module Conversion Adapter DIN rail mounting bracket bottom Fixture has been installed to the Conversion Adapter Fixture installation screw M3 x 8 supplied with Conversi
5. Module When installing the Conversion Adapter take care not to get your hand snagged on the Mounting Bracket or the like Injury may result Wiring Precautions WARNING Before attempting to install the Unit or carry out the necessary wiring make certain that the external power supply used in the system is shut off on all three phases Failure to do so may result in electric shock or damage to the product After installation and wiring close the terminal block cover before turning on the module for operation Failure to do so may result in electric shock Wiring Precautions N CAUTION Carry out wiring for the Conversion Adapter correctly after checking the specification and terminal arrangement for the module used Connecting a power supply with a different voltage rating or incorrect wiring may cause a fire or failure Tighten the MELSEC AnS Series terminal installation screws and terminal screw securely by applying torque within the specified limits Loose screws will cause short circuit fire or malfunction Excessive tightening will damage the screws or the Conversion Adapter which in turn will cause dropping of parts short circuit or malfunction Use care to prevent foreign materials including cuttings and wiring debris from entering the Conversion Adapter or the MELSEC Q Series Module These will be cause for fire failure or malfunction Startup and Maintenance Precautions Do not tou
6. an easy to access location for future reference and be sure to provide the manual to the end user Precautions before using CAUTION When making a switch from the MELSEC AnS Series to the MELSEC Q Series be sure to consult user s manual supplied with individual module under the MELSEC Q Series to confirm differences in various aspects including performance function CPU input output signals and buffer memory addresses between the two series Installation Precautions CAUTION Use the Conversion Adapter in the environmental conditions that are specified in the general specification If the Products are used in any environment beyond the bounds of the general specification electric shock fire malfunction or damage to or degradation of the Products will result Do not directly touch any conductive parts of Conversion Adapter Contact will cause malfunction or failure in the system Fasten the Conversion Adapter securely with retaining screws and tighten the screws by applying torque within specified limits Loose screws can lead to the dropping of the Conversion Adapter possibly causing breakage thereof Excessive tightness of the screws can lead to breakage of the screws Conversion Adapter or MELSEC Q Series Module possibly causing the dropping shorting and malfunction thereof Always check for correct match between MELSEC Q Series and the Conversion Adapter Incorrect match can cause damage to the MELSEC Q Series
7. cause malfunction or failure in the system 5 The protective wrap is used to protect your hands from touching the conductive part in the pin setting process Peel it off after finishing the settings In addition make sure to peel it off before installing a MELSEC AnS Series terminal block 6 Fasten the Conversion Adapter securely with retaining screws and tighten the screws by applying torque within specified limits Loose screws can lead to the dropping of the Conversion Adapter possibly causing breakage thereof Excessive tightness of the screws can lead to breakage of the screws Converter Adapter or MELSEC Q Series Module possibly causing the dropping shorting and malfunction thereof 7 Use care to prevent foreign materials including cuttings and wiring debris from entering the Conversion Adapter or the MELSEC Q Series Module These will be cause for fire failure or malfunction 8 Do not drop the Conversion Adapter or do not give a strong impact to it This will cause damage 4 2 Use Precautions Width dimension of module Because the module is reduced in width dimension 34 5mm gt 27 4mm and thus in area available for wiring check dimensional data before installing the module lt MELSEC AnS Series gt lt MELSEC Q Series gt 34 5mm 27 4mm Depth and Height dimension Installation with the Base Adapter Because the module is increased in depth dimension check dimensional data before installing th
8. 0 O B19 nis Open 420 B20 B15 Open A16 C V B16 H VE A7 7 B17 Open A18 Open B18 C V A19 H V B19 8 I A20 Open B20 Open lt Specification comparison gt Model MELSEC AnS Series MELSEC Q Series Specification E A1S68AD Q68AD G Voltage 10 to 0 to 10VDC Input resistance 1MQ or more Analog input Current 0 to 20mA Input resistance 2500 Digital output 16 bit signed binary 16 bit signed binary Normal resolution mode 4096 to 4095 High resolution mode 12288 to 12287 16384 to 16383 Using scaling function 16 bit signed binary 32768 to 32767 input Ansioa iibut rahe Normal resolution mode High resolution mode Analog input range Digital output R np g Digital output value Resolution Digital output value Resolution 0 to 10V 0 to 4000 0 to 10V 2 5mV 0 to 16000 0 625mV VO charagtoristics 10 to 10V 2000 to 2000 Oto 5V 0 to 4000 1 25mV 0 416mV 0 to 5V or 0 to 20mA 0 to 4000 1 to 5V 1 0mV 0 to 12000 0 333mvV 1 to 5V or 4 to 20mA 0 to 4000 Voltage TaS 1000 to 4500 1 0mV 3000 to 13500 0 333mV Extended mode 10 to 10V 2 5mV 16000 to 16000 0 625mV i i 4000 to 4000 Analog input range Resolution Users range setting i 0 375mV 12000 to 12000 0 333mV 0 to 10V 2 5mV 0 to 20mA 5A 1 66pA 2 0 to 4000 0 to 12000 i Maximum resolution S hs e
9. 1 AN 4 to 20mA K 4uA 2 1 33 UA Ci t 1 to 5V mV reg aio Zones 1000 to 4500 4uA 3000 to 13500 4 33pA Oto 20mA 5uA Extended mode H Users range setting 4000 to 4000 1 374A 12000 to 12000 1 33 A Ref 1 Normal resolution mode 4digit 2 Soral a slenceaccuracy Digital ets ut veler 0 1 High resolution mode 0 to 10V 10 to 10V 16digit 2 ete 9 4 High resolution mode Other than the above ranges 12digit 2 y Temperature coefficient_ 3 71 Appm C 0 00714 C Maximum conversion speed Sampling cycle 4 0 5ms channel 5 10ms channel Response time 6 20ms Absolute maximum input Voltage 35V Current 30mA Voltage 15V Current 30MA Operating ambient temperature Storage ambient 0 to 55 C Maximum surrounding air temperature 55 C Analog input points 8 channels module Between input terminal and programmable Photocoupler isolation Transfomer isolation 25 to 75 C Isolation temperature Method controller power supply Operating ambient Between analog input Non isolated Transfomer isolation humidity x and channels 5to 95 RH non condensing Fi 7 z P Storage ambient Number of I O occupied points 32 points 16 points humidity Wiring connection system 20 point terminal block 40 pin connector Constant Half Sweep Internal current consumption 5VDC 0 4A 0 46A Frequency acceleration count 5 to 8 4Hz amplitude 3 5mm Under in
10. He 5 TB12 CH6 TB13 CH5 TB13 CH5 ONE i TB14 CH6 d 2 TB1S AG 2 TBIS AG Notrequed TB16 AG TB16 AG CH7 TB17 CH7 cH eee l TBT CH7 TB18 CH8 T TB18 CH8 TB19 CH7 TB19 CH7 ehis TB20 CHS go e AE Furthermore it is recommended to refer to the Transition from MELSEC AnS QnAS Sma Conversion Adapter MELSEC AnS Series No of MELSEC Q Series Se Model channels Model Weight g ERNT ASQT68AD G A1S68AD 8 channels Q68AD G 100 Internal circuit diagram of ERNT ASQT68AD G ED pin Terminal Signal Terminal Signal No Name No Name gt TB1_ CHi A1 C V A1S68AD TB2 CH2 BI H VE Terminal Block TB3 CH1 A2 1 l TET TB4 CH2 B2 Open TB2 53 gt TBS AE A3 Open TB4 TB6 A B3 V TBS Has TB7 CH3 a hv SE8ADG TB8 HBg TB8 CH4F B4 2 T pa TB10 67 TB9 CH3 a5 oen a Sole TEI a5 TB10 CH4 B5 Open M oo lB TB14 eis TB11 CH5 a fev A o 6 B TB16 e17 TB12 CH6 B6 H VE A4 O 0 B4 TB18l B19 TB13 CH5 AT lakie s loo Bs TB20 TB14 CH6 B7 Open TB15 AG A8 Open 46 O B6 gt TBi6 AG Bec ve AZ 9 9 B7 TB17 CH7 AQ__ H V I 48 9 B8 TB18_ CH8 B9 4 m A9 9 0 B9 TB19 CH7 A10 Open 10 B10 TB20 CH8 B10 Open 11 0 O B11 Kir c ve A12 0 O B12 BIr Hiva A13 0 O B13 Riz si A14 0 O B14 B12 Open A15 0 B15 M3 Open A16 0 B16 B13 cr v A17 0 0 B17 Ait Hvi A18 0 O B18 Biy lei A19
11. U v v q Mount the MELSEC Q Series module to the MELSEC Q Series Base Unit Install the Conversion Adapter to the MELSEC Q Series module and secure it with the Conversion Adapter installation screws M2 6x20 2 places Precaution Before tightening the installation screws check that the Conversion Adapter has been securely installed on the MELSEC Q Series module Tightening the screws in floating off state or tilting state will damage the Conversion Adapter installation screws and the MELSEC Q Series module a Secure the fixture to the Base Adapter or Conversion Adapter DIN rail mounting bracket bottom of the Conversion Adapter with fixture installation screws M3 x 8 1 place Secure the MELSEC AnS Series terminal block to the Conversion Adapter with the supplied terminal block installation screw M4 2 places top and bottom a Remove the terminal block cover from the MELSEC AnS Series terminal block and fit the terminal block cover supplied with the Conversion Adaptor in place 6 2 Tightening Torque Tighten the module installation screws to the specified torque below An inappropriate tightening torque could cause the product to fall or result in a short circuit product failure or malfunction Screw Location 0 20 to 0 29N m 0 61 to 0 82N m 0 78 to 1 18N m Conversion Adapter installation screw M2 6x20 Fixture installation screw M38 MELSEC AnS Series terminal block installation s
12. X Y and buffer memory addresses are allocated Therefore you need make necessary changes to the sequence program that is used Precautions for the program 4 The cycle in which A D conversion values are updated 5 The maximum conversion speed is 1 ms channel on all channels if averaging processing is set even for only one channel 2 Set the input range using the intelligent function module switch setting in the Q68AD G instead of the DIP switches that are used in the A1S68AD POINT 1 When an error occurs in the digital output value the error can be corrected using the offset gain setting in the Q68AD G 6 The time required for an input signal to reach the A D converter inside the Q68AD G section of the above table meets the specification of the machines and equipment connected to the MELSEC Q Series module 4 Mounting and Installation 4 1 Handling Precautions 1 Before attempting to install the Unit or carry out the necessary wiring make certain that the external power supply used in the system is shut off on all three phases Failure to do so may result in electric shock or damage to the product 2 Do not touch live terminals There is a danger of electric shock or malfunction 3 Do not modify the Conversion Adapter or take it apart Doing so will cause failure malfunction personal injury or fire 4 Do not touch the energized part of the Conversion Adapter directly Contact will
13. ch live terminals There is a danger of electric shock or malfunction Shutoff the external power supply for the system in all phases before cleaning or retightening the terminal screws Failure to do so may result in electric shock or cause the MELSEC Q Series module to fail or malfunction Loose screws can lead to dropping shorting and malfunction Excessive tightness of the screws can lead to breakage of the screws Conversion Adapter or MELSEC Q Series Module possibly causing the dropping shorting and malfunction thereof N CAUTION Do not modify the Conversion Adapter or take it apart Doing so will cause failure malfunction personal injury or fire Do not drop the Conversion Adapter or do not give a strong impact to it This will cause damage Disposal Precautions When disposing of the product treat it as industrial waste EMC AND LOW VOLTAGE DIRECTIVES Compliance to the EMC Directive which is one of the EU Directives has been a legal obligation for the products sold in European countries since 1996 as well as the Low Voltage Directive since 1997 Manufacturers who recognize their products are compliant to the EMC and Low Voltage Directives are required to declare that print a CE mark on their products Authorized representative in Europe Authorized representative in Europe is shown below Name Mitsubishi Electric Europe BV Address Gothaer strasse 8 40880 Ratingen Germany 1 Overview This manual
14. crew M4 screw Please confirm the following product warranty details prior to product use Gratis Warranty Terms and Gratis Warranty Range If any fault or defect hereinafter referred to as Failure attributable to Mitsubishi Electric Engineering Company Limited hereinafter referred to as MEE should occur within the gratis warranty period MEE shall repair the product free of charge via the distributor from whom you made your purchase I Gratis Warranty Period The gratis warranty period of this product shall be one 1 year from the date of purchase or delivery to the designated place Note that after manufacture and shipment from MEE the maximum distribution period shall be six 6 months and the gratis warranty period after manufacturing shall be limited to eighteen 18 months In addition the gratis warranty period for repaired products shall not exceed the gratis warranty period established prior to repair i Gratis Warranty Range The gratis warranty range shall be limited to normal use based on the usage conditions methods and environment etc defined by the terms and precautions etc given in the instruction manual user s manual and caution labels on the product Warranty Period after Discontinuation of Production 1 MEE shall offer product repair services fee applied for seven 7 years after production of the product has been discontinued Discontinuation of production shall be reported via dis
15. e module MELSEC AnS MELSEC Q Series Conversion Adapter Base Adapter 157 5mm Z 47 5mmUP Installation with the DIN rail Because the module is increased in depth and height dimension check dimensional data before installing the module MELSEC AnS 7 Sais p MELSEC Q Series sit Conversion Adapter Conversion Adapter DIN rail mounting bracket Terminal block The terminal block cover for MELSEC AnS Series is bigger than the width of cover the MELSEC Q Series Module Therefore it is necessary to replace it with the terminal block cover supplied with the converter adapter lt MELSEC AnS Series gt lt MELSEC Q Series gt Terminal block cover for the MELSEC AnS Series Replace the terminal block cover with the lone supplied with the Conversion Adapter 4 5m 34 5mm 4 3 Installation Environment For details of the installation environment refer to the user s manual of the MELSEC Q series CPU module to be used 5 Preparation before Installation 5 1 Position of the setting pins Open the cover of the Conversion Adapter and you will find the setting pins to switch the voltage input and current input With the cover closed HS With the cover opened Protective wrap Protective wrap Display nameplate Ta
16. on Adapter MELSEC AnS Series terminal block installation screw M4 Conversion Adapter installation screw M2 6 x 20 Conversion Adapter XThe separately sold Conversion adapter DIN rail mounting bracket ERNT ASQDIN is required to use this Conversion Adapter Refer to the user s manual of the DIN rail mounting bracket of the Conversion Adapter for the installation method 6 1 Installation Method Make sure to set the setting pins before installation 7 External Dimensions S ft Unit mm 102 27 4 E Terminal block cover 9 5 Ol J 2 3 4 5 Nct 6 7 3l 9 A Al B a Cc 5 F ey S Product Warranty Details Installation with the Base Adapter Installation with the DIN rail Mount the MELSEC Q Series Base Unit to the Base Adapter Refer to the Base Adapter s manual for how to install them to the control panel Mount the MELSEC Q Series Base Unit to the DIN rail mounting bracket of the Conversion Adapter and the adapters for DIN rail installation manufactured by Mitsubishi Electric For how to mount them to the DIN rail refer to the user s manual of the Conversion Adapter DIN rail mounting bracket and QCP
17. provides information about the Conversion Adapter ERNT ASQT68AD G available as Renewal Tools for the Mitsubishi General Purpose Programmable Controller The Conversion Adapter is a product for effecting conversion to transcend difference in pin assignment between the MELSEC AnS Series and the MELSEC Q Series Before attempting to make a switch from MELSEC AnS Series to MELSEC Q Series in your installation consult the user s manual supplied with individual module under the latter series to learn about how they differ in various aspects including performance and function Once you have opened the packaging verify that it contains the following products Conversion Adapter Fixture installation screw M3x8 Terminal block cover Short bar spare parts 2 General Specifications Item Specifications 3 Product Specifications For detail specifications which do not appear in the specification comparison charts contained herein see the user s manual supplied with the MELSEC Q Series module you use Those parts of the specification that differ between the MELSEC AnS Series and the MELSEC Q Series are where a switch from the first series to the second is subjected to specification related restrictions Check the specification of the devices to be connected for more details
18. termittent vibration Under continuous vibration Compliant with JIS B 3502 and IEC 61131 2 147 m s 3 times each in 3 directions X Y Z No corrosive gases 0 to 2000m Inside a control panel Il or less 10 times each in X Y Z directions Compliant with JIS B 3502 and IEC 61131 2 Vibration resistance 9 8m s 8 4 to 150Hz 5 to 8 4Hz 8 4 to 150Hz 4 9m s Shock resistance Operating atmosphere Operating altitude 1 Installation location Overvoltage category 2 Pollution degree 3 2 1 Do not use or store under pressure higher than the atmospheric pressure of altitude Om 2 This indicates the section of the power supply to which the equipment is assumed to be connected between the public electrical power distribution network and the machinery within premises Category II applies to equipment for which electrical power is supplied from fixed facilities 3 This index indicates the degree to which conductive material is generated in terms of the environment in which the equipment is used Pollution level 2 is when only non conductive pollution occurs A temporary conductivity caused by condensing must be expected occasionally 1 Accuracy of offset gain setting at ambient temperature 2 digit indicates a digital value 3 Accuracy per temperature change of 1 C Make sure the 1 A1S68AD and Q68AD G differ from each other in the way input output signals
19. tributors 2 Product supply including spare parts is not possible after production has been discontinued Exclusion of Opportunity Loss and Secondary Loss from Warranty Liability Regardless of the gratis warranty period MEE shall not be liable for compensation for damages arising from causes not attributable to MEE opportunity losses or lost profits incurred by the user due to Failures of MEE products damages or secondary damages arising from special circumstances whether foreseen or unforeseen by MEE compensation for accidents compensation for damages to products other than MEE products or compensation for other work carried out by the user Changes in Product Specifications The specifications given in the catalogs manuals and technical documents are subject to change without notice This document is a new publication effective September 2014 Specifications are subject to change without notice Developed September 2014 50CM D180119 C