RAV4 EV Monitor User..
Contents
1. is switch off or the device is disconnected the device will switch off cancel depending on the timeout settings RAV4 EV Monitor User Manual 3 4 How to s for Palm Hard reset palm device 1 Press and hold the Power on off button on the front panel of your device 2 While holding Power use an unfolded paper clip or the reset tool at the tip of your stylus Gently press and release the RESET button inside the hole on the back panel of your device where s the reset hole If you see a progress bar see below keep holding the Power button Next the Palm Powered screen will appear Release the Power button when you see it 5 You ll see a screen that asks Erase all data YES up button NO any other button Press UP on your 5 way navigator to complete the hard reset AR Soft reset palm device 1 Use an unfolded paper clip or the reset tool at the tip of your stylus 2 Gently press and release the RESET button inside the hole on the back panel of your device 3 After a soft reset a logo screen appears followed shortly by a Preferences screen asking you to set time and date 4 All data on your device should be retained Background light Switching on off of the background light of a palm device is done via pressing and holding the ON button the semi transparent button on the top edge next to the right top corner of the device The m515 has a possibility to adjust background light tap on
2. RAV4 EV Monitor User Guide Introduction Pack voltage RAV4 EV Monitor is a software program for collecting information from RAV4 electric cars produced between 1998 to 2003 It is not compatible with any other vehicle The software runs on palm handheld hardware and requires interface cable that connects the palm to the car s OBD port It is recommended that the software is run on a palm m505 or m515 device with background light v Battery CA3 switched off or set on low Both m505 and m515 feature reflective color screen which is very visible in most orientations Installation There are 3 major ways of installing the software hotsync sd card beaming Hotsync Installation of the software is done via Palm Desktop HotSync Manager application downloadable from www palm com http kb palm com SRVS NUA launchTab asp t home amp fn m series amp mn m515 amp cn unlocked Once the Palm Desktop applications are installed a double click on the RAV4EVMonitor rpce file will schedule the software for installation with the next synchronization Please note that the synchronization between pc and palm is started via the palm device tap on the home and then on the HotSync icon If you experience any problems with the synchronization please see here for an excellent step by step trouble shooting http kb palm com wps portal kb common article 2630_en html SD Card Installation and running of
3. e two communication modes available the Battery and the Check The Battery communication mode allows monitoring of limited number of parameters It pays off with much faster refresh rate of parameters values compared to the Check mode The Check mode allows for monitoring all individual module voltages and internal resistances RAV EV Monitor o oN N General il Ha charge A a While the interface allows for monitoring only 7 parameters at one time Pack voltage W T all parameters for the currently selected communication mode are logged Power kw 008 The frequency of the logging time between each log row can be adjusted Max module w w 0 0 via the configuration button Min module v Y 0 0 Aug module w v The main screen of the program contains 4 large and 3 smaller parameter view boxes each of them displays one a parameter For parameters that have color Parameter to monitor i settings the view boxes change background Modwvolt 24 v color depending on the value of the parameter Current 4 Pack voltage V Power ki To change the parameter displayed in a particular view box just tap on the ModintRes 1 mOhm view box and list with possible parameters will be displayed Tap on the ModIntRes 2 moh desired parameter and select the done button The 4 large parameter view _ ocilntRes 3 rmOhm boxes display parameter name and unit while the small ones do not ler ee Seiten a display the parameter
4. n the buttons changes to reflect the selected communication mode BBV Ba Batteryc100 RAV EV Monitor C ONO INI Logging Fack voltage a All monitored parameters can be saved on a storage card The log location can be changed via the configuration dialog Logs save all parameter data in a semicolon delimited format the names of the logs are in the following format lt communication mode name gt _yyyymmdd log where yyyymmdd is the current date Example of name Battery _20090418 csv contains logged data from BMS from 18 of April 2009 Battery C85 The palm device is compatible with normal SD cards do not use SD HC cards and cards with size of maximum 1GB There is no need to insert the card and then start program The program will recognize the card whenever inserted and will start logging immediately if the option log if card is present 1s checked All logs are saved to the root folder of the SD card Configuration Configuration All program configuration settings are remembered between program O log if card is present restarts log every 120 second s All display configuration monitored parameters and current screens are O keep on even if ne signal also remembered between program restarts The palm device is maintained in on state as long as there is information coming from the car When such information stops coming when the car
5. name Any of the parameter view boxes can display any parameter for the currently selected ECU Status bar On the top of the screen there is a status bar it displays current status and log status If the application RAV4 EV Monitor User Manual 2 4 currently logs data the letter L is displayed If the application for some reason is not logging data then the letter N is displayed The log settings can be changed via the configuration button INP is displayed if the device has not established connection with the car Fimbienttemp Firstsensor It can take up to 60 seconds for the device to establish connection For a n D b J connection to be established the car computers need to be On either z L started with when the car is started with a key or when charging econd senzor Second sensor b b b b The current communication mode can be Ry Bw By changed via the control on the lower left corner CONE sen con P EA es d m tap on the control and select different GETS N CON Battery cog communication mode For each communication mode there are four screens with 7 parameter view boxes each The screens are changed by taping on one of the B1 B2 etc buttons The letter i
6. the software is possible via SD card Put an empty SD card in your computer and create a folder named PALM Then move to the newly created PALM folder and in it create a subfolder named launcher After that copy the prc file to the launcher folder on the SD card Eject the SD card from your pc and insert it in the slot on the palm handheld The palm should open up with the icon of the program RAV4 EV Monitor User Manual 1 4 IR Beaming Many laptops have IR beaming capability just point the palm handheld while it is on with it s top to the IR port of the computer In Windows XP a small popup with show up and offer to exchange files Select the prc file and beam it to the palm device After installation After installation the RAV4 EV Monitor program the tap on the icon of the program to start it Note that in most cases it would necessary to scroll down to make the RAV4 EV Monitor icon visible Once the RAV4 EV Monitor program is installed it could be associated with one of the hardware buttons on the device To do that tap on Preferences icon and then choose buttons from the top right corner click next to the button icon for the button you would like to use to start the program and choose RAV4 EV Monitor from the list Interface and functions Once started the RAV4 EV Monitor automatically attempts to connect using the last communication mode Currently there ar
7. the upper right hand corner to the left of the calculator shortcut A prompt to select screen brightness will popup Palm s operating system does not allow for real multitasking and it is recommended that the palm device used for monitoring is used only for that More information about palm devices can be found at http kb palm com RAV4 EV Monitor User Manual 4 4