Home

User Manual - Spa Central

image

Contents

1. __ IMPORTANT Some models are fitted with a thermal cut out thermostat which acts as a Non self resetting thermal cut out In the unlikely event of a fault condition this device is designed to open the power circuit between190 F 14 F 88 C 8 C It is not possible to alter its operating range The operation of the unit may be restored by depressing the red button after the water element temperatures have been allowed to cool If the fault condition persists please contact Chattanooga Group or an authorized agent NOMENCLATURE Mi o ycollator Mobile Heating Units Diagram 1 Heating Element 9 Junction Box J Box Cover 2 Drain 10 IEC connector 3 Overtemp Thermostat 11 Power Cord 4 Thermostat Hydraulic 12 Drain Valve Not Shown 5 Bracket Brkt amp Bulb Themo A B Assembly 13 Reset Overtemp Button 6 Lid 14 Fuses 7 3 inch Caster 15 Pilot Lamp Red 8 Overtemp Light 16 Pilot Lamp Clear NOTE M 4 model shown models will vary All 220 240 Volt and M 4 120 Volt have this button NOMENCLATURE y drocollator Mobile Heating Units Diagram continued 17 Hot Pac 23 Side Handle 18 Neck Pac Insert 24 Thermostat Hydraulic 19 Drain Copper Tube 25 Thermostat Control Knob 20 Lid Hinge nuts 26 On Off Switch 21 Lid Knob Handle 27 Internal Wiring Harness 22 Lid Hinge 23 gt Not illustrated Stainless Steel Wire Rack DrainVa
2. Ball 1 2 in Replacement 21085 30 Drain Hose Bib 23302 31 Replacement Tank M 2 56314 32 M 2 Outer Jacket 22421 34 Handle Lid Kit 22171 26 On Off Switch 23406 Key numbers refer to Nomenclature section pages 5 and 6 Used to hold the Hydraulic Thermostat and Overtemp Thermostat to the Heating element Includes Gasket Thermostat Nut 1 2 20 Brass and Overtemp Thermostat 26 11 REPLACEMENT PARTS l Hydrocollator Mobile Heating Units Model SS 2 Standard Cat No 2302 w packs Key Part Description Part No 1 Element Heating 120 Volt 1000 Watt 10630 4 Hydraulic Thermostat 10631 5 Brkt amp Bulb Thermostat A B Assembly 2 each 21023 6 Lid SS 2 22219 7 Caster 3 inch 4 21259 9 Cover Junction Box 22087 11 Power Cord 20568 Hose Drain 21635 15 Pilot Lamp Red 22149 16 Pilot Lamp Clear 22148 19 Drain Copper Tube Part A 21286 20 Lid Hinge Rod Nuts 2 each 21737 21 Lid Knob Handle 21025 22 Lid Rod Hinge 22231 23 Handle Side 2 20237 Thermo Low Water Kit 20548 27 Wiring Internal Harness 61579 28 Stainless Wire Rack 22259 29 DrainValve Ball 1 2 in Replacement 21085 30 Drain Hose Bib 23392 31 Replacement Tank SS 2 23385 32 SS 2 Outer Jacket 22425 34 Handle Lid Kit 22171 25 Water Thief 21882 26 On Off Switch 23406 Key numbers refer to Nomenclature section pages 5 and 6 Used to hold the Hydraulic Thermostat and Overtemp Thermostat to the Heating element Includes Gasket Thermosta
3. M 4 Model Power Supply Rated Frequency Power Consumption Tank Capacity Temperature Range Thermal Cut out Temp Accuracy Heating Up Time Cool Down Time Safety Class Safety Tests Dimensions Weight 110 120V 220 240V 50 60Hz 1500 W 135 76 Liters 160 F 165 F 71 C 74 C 190 F 14 F 88 C 8 C 10 Time to 160 F 70 C 8 Hours Time from 160 F 70 C 4 Hours Type B UL 544 33 in Hx 35 in L x 20 in W 85 cmH x 89 cm L x 50 cm W 55 Ibs 25 kg Standard Accessories Includes twenty four Standard size HotPacs SETU P Hydrocollator Mobile Heating Units Remove all of the contents inside the Hydrocollator and then replace the wire rack Make certain the drain valve is closed before filling the tank with water The tank should be approximately 3 4 full with packs removed The tank may be filled from any standard type faucet Check the voltage rating on the serial decal plate which is located on the back of the unit To turn the unit on simply plug the unit into a 120 Volt 60 Hz or 220 240 Volt 50 60 HZ outlet as indicated on the decal plate To turn the unit off simply unplug from mains power supply Do not attempt to use direct current Follow the procedures indicated in the Precautionary Instructions Do not attempt to use the unit if it is not properly grounded OPERATION E Hydrocollator Mobile Heating Units The Hydrocollator is simple and easy to operate The controls are located i
4. Hydrocollator MOBILE HEATING UNITS User Manual 120 220 240 Volt Units TABLE OF CONTENTS Hydrocollator Mobile Heating Units POKES WOM earen EEEE EE EEE neue ILE 2 Precautionary Debit lOS ince giao conn Eoo md CPGE IET aaa 2 3 Nopnieliclatulfgoseeeewe sene RERO ORE RR e EFI ERERI ND LEEFPEREE CREE PIN 4 6 Technical Specifications sse IRI 7 8 1l KeT 9 Dela cs vss dii LUTE PU IU PPM P ERUPEPLPR NSE PUPPES ENSEM PIER did 9 Troubleshooting s uua dons eR PEE REI ORE Eo OE Sor ta 10 Replacement Parts 0 ccc ccc eect cence teen eect eh hh 11 13 Mud P oy ERa T 14 15 WOMAN EEEIEE E E E sone tenes Bade ERED IMEEM EE RITU 16 Hydrocollator is a registered trademark of Chattanooga Group HotPac is a trademark of Chattanooga Group 2006 Encore Medical Corporation or its affiliates Austin Texas USA Any use of editorial pictorial or layout composition of this publication without express written consent from Chattanooga Group of Encore Medical L P is strictly prohibited This publication was written illustrated and prepared for print by Chattanooga Group of Encore Medical L P CHATTANOOGA bm GROUP Sie ISO 13485 CERTIFIED FOREWORD Hydrocollator Mobile Heating Units This manual contains general instructions for operation precautionary instructions and maintenance recommendations for the owners and operators of the Hyd
5. Lo Water 2 16 Part No 22246 10631 22146 23406 22374 21635 21260 20513 22348 22360 21286 22356 21882 22173 20548 22147 74723 23384 21737 22361 21085 23392 21023 MAINTE NANCE l Hydrocollator Mobile Heating Units Care and Cleaning The Hydrocollator is equipped with an immersion type heating element and a hydraulic capillary type thermostat which evenly maintains the HotPac temperature in the water and provides a ready supply of heated packs It is critical to maintain the water level over the top of the HotPac to avoid damage to the heating element the stainless steel or the HotPac Water is constantly lost during operation due to evaporation Therefore it is essential that water be added daily The tank should also be drained and cleaned systematically at minimum intervals of every two weeks Always unplug the unit from the power source when emptying or cleaning the unit Drain the unit by the drain valve located at the bottom rear of the unit Either move the unit to a floor drain or attach the extension hose to it when draining N WARNING e Do not move the Hydrocollator while filled with water Tipping over could result in a burn to the user or others e Always unplug the Hydrocollator from the power source before attempting to empty water from unit Your Hydrocollator Heating Unit is made of high quality stainless steel that should last a lifetime You must properly care for your Hydrocollator He
6. ating Unit if you wish for it to last a lifetime Follow these simple steps to ensure that your Hydrocollator Heating Unit lasts 1 Chlorine means rust to stainless steel No bleach or any cleaner with high chlorine content should be used 2 Clean regularly for optimal service and operation NOTE Failure to maintain your equipment including regular cleaning will void your warranty 3 Fill daily with water Water is constantly lost during operation due to evaporation Chlorine in regular tap water may be present in high enough concentrations to damage your unit If you suspect high levels of chlorine in your Hydrocollator Heating Unit we recommend the addition of a dechlorinator 5 Certain additives such as herbal teas essential oils etc will damage the components of the heating unit including the stainless steel The Hydrocollator Heating Unit was designed to heat water and HotPacs only To avoid potential for rusting Do not use bleach or cleaners with high chlorine content Do not use paper clips safety pins staples coat hangers etc in or on the unit Do not clean the unit with steel wool or a carbon steel brush Do not use abrasive cleaners which tend to disturb the grain in the finish Water level is critical Add water daily and keep it full Regularly clean and drain the tank every two weeks DW dew SE ue RR Remove all deposits from interior surfaces and parts including heating element The deposits are c
7. ct THE FOREGOING WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING ANY WARRANTY OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE 19 CHATTANOOGA A GROUP ss ISO 13485 CERTIFIED 4717 Adams Road P O Box 489 Hixson TN 37343 1 423 870 2281 USA 1 800 361 6661 Canada 1 423 870 7200 Outside U S A 1 423 870 2046 Fax chattgroup com 2006 Encore Medical L P 22151B
8. ill not retain heat properly The pack should be replaced when it reaches this state Original replacement Hydrocollator HotPacs may be ordered from an authorized Chattanooga Group dealer NOTE If HotPacs are to be stored for extended periods they may be placed while wet in plastic bags and stored in a freezer 18 WARRANTY Hydrocollator Mobile Heating Units Chattanooga Group Company warrants that the Hydrocollator Models SS 2 M 2 and M 4 Heating Units Products are free of defects in material and workmanship This warranty shall remain in effect for one year from the date of original consumer purchase If these Products fail to function during the one year warranty period due to a defect in material or workmanship Company or the selling dealer will repair or replace this Product without charge within a period of thirty days from the date on which the Product is returned to the Company or the dealer All repairs to the Product must be performed by a service center authorized by the Company Any modifications or repairs performed by unauthorized centers or groups will void this warranty To participate in warranty coverage this Product s warranty registration card included with Product must be filled out and returned to the Company by the original owner within ten 10 business days of purchase This Warranty Does Not Cover Replacement parts or labor furnished by anyone other than the Company the selling dealer or a cer
9. ion Element Heating 240V CE Thermostat Hydraulic Lamp Pilot Green Cord Set Country Specific Switch Rack Hose Nylon 5 8 x 4 Coupled M F Caster 3 in 4 Handle M SS Lid Finished Handle Side Common 2 Lid Assembly With Handle Cover Junction Box M 2 220 240 Volt Drain Copper M 2 Part A 25010 Bracket Bulb Thermostat H20 S A Lo Water 2 Water Thief Spacer Thermostat Lo Water 2 Thermostat Lo Water Lamp Red Indicator Lo Water Fuse 6 3 Amp 2 Fuse Holder 2 Receptacle Power 8843 FSG W 40 60 Harness Wiring Tank Replacement with Drain Insert For neck Contour Packs Thermostat LM5 2505 Lid Rod Nuts 2 Lid Rod Valve Ball Fit Bib SS2 M2 M4 14 Part No 22245 10631 22146 23406 22259 21635 21259 20513 20237 22219 22087 21286 21023 21882 72393 20548 22147 71772 72734 74723 61579 23372 21053 23393 21737 22231 21085 23392 REPLACEMENT PARTS Hydrocollator Mobile Heating Units Model M 2 220 240 VOLT Low Water Cat No 2407 w packs Cat No 2409 w o packs Key 1 4 26 28 23 34 29 35 15 27 31 20 22 29 Part Description Element Heating 220 Volt 1000 Watt Thermostat Hydraulic Lamp Pilot Green Cord Set Country Specific Switch Rack Hose Nylon 5 8 x 4 Coupled M F Caster 3 in 4 Handle M SS Lid Finished Handle Side Common 2 Lid Assembly With Handle Cover Junction Box M 2 220 240 Volt Drain C
10. lve Ball 1 2 in Replacement Replacement Tank Outer Jacket Fuse 10A Lid Kit Handle Water Thief Plastic Feet Drain Hose Bib Back View Bracket Element Support 2 each M 4 only TECHNICAL SPECIFICATIONS Hydrocollator Mobile Heating Units SS 2 Model Power Supply Rated Frequency Power Consumption Tank Capacity Temperature Range Thermal Cut out Temp Accuracy Heating Up Time Cool Down Time Safety Class Safety Tests Dimensions Weight 110 120V 220 240V 50 60Hz 1000 W 49 32 Liters 160 F 165 F 71 C 74 C 190 F 14 F 88 C 8 C 10 Time to 160 F 70 C 4 Hours Time from 160 F 70 C 2 Hours Type B UL 544 33 in Hx 21 in Lx 16 in W 85 cm H x 52 cm L x 39 cm W 30 Ibs 13 6 kg Standard Accessories Includes eight Standard size HotPacs M 2 Model Power Supply Rated Frequency Power Consumption Tank Capacity Temperature Range Thermal Cut Out Temp Accuracy Heat Up Time Cool Down Time Safety Class Safety Tests Dimensions Weight 110 120V 220 240V 50 60Hz 1000 W 68 81 Liters 160 F 165 F 71 C 74 C 190 F 14 F 88 C 8 C 10 Time to 160 F 70 C 6 Hours Time from 160 F 70 C 3 Hours Type B UL 544 33 in Hx 27 in Lx 16 in W 85 cm H x 67 cm L x 40 cm W 37 Ibs 16 8 kg Standard Accessories Includes twelve Standard size HotPacs TECHNICAL SPECIFICATIONS Hydrocollator Mobile Heating Units
11. n the rear near the bottom of the unit The thermostat controls the temperature of the water It is located near the bottom of the unit on the control panel It has been tested and preset at the factory to normal operating temperature If further adjustment is necessary it can be easily accomplished by turning the adjusting screw located on the thermostat Turning the outer screw counterclockwise lowers the temperature while turning it clockwise raises it NOTE Do not turn the inner stem The Hydrocollator units operate through the use of a hydraulic capillary type thermostat and can be left plugged in and turned on to provide a ready supply of heated HotPacs The HotPac rack is adjustable and accommodates different sizes and types of packs SS 2 Unit The unit comes complete with eight standard HotPacs M 2 and M 4 Units The M 2 unit comes complete with 12 standard HotPacs The M 4 comes complete with 24 standard HotPacs TROU BLESHOOTI NG Hydrocollator Mobile Heating Units The following are solutions to minor performance problems Only qualified personnel should service equipment problems PROBLEM POSSIBLE CAUSE POSSIBLE SOLUTION Unit Plugged In Breaker for electric circuit off 1 Turn breaker ON Water Doesn t Get Hot Thermostat not functioning 2 Replace thermostat Heating element burned out 3 Replace element Filler from packs is seeping Replace packs Cloudiness of Water Too long a peri
12. od between Drain and clean cleanings Thermostat set too high 1 Adjust thermostat Thermostat failure 2 Replace thermostat Packs Too Hot N Thermostat set too low 1 Adjust thermostat Packs Too Cool Thermostat failure 2 Replace thermostat Unit Boils 1 Thermostat failure 1 Replace thermostat 1 Remove the ferrous metal item from the unit usually a staple paper clip safety pin etc and clean thoroughly 1 Contact with ferrous metal Rust 2 Thoroughly clean tank and remove all deposits 2 Deposits on inside of tank Clean tank and rinse thoroughly Add de chlorinator if local water has high chlorine content 3 Too much chlorine in water 10 REPLACEMENT PARTS Hydrocollator Mobile Heating Units Model M 2 Standard Cat No 2402 w packs Key Part Description Part No 1 Element Heating 120 Volt 1000 Watt 10630 4 Hydraulic Thermostat 10631 5 Brkt amp Bulb Thermostat A B Assembly 2 each 21023 6 Lid 22297 7 Caster 3 in 21259 9 Cover Junction Box 22087 11 Power Cord 20568 Hose Drain 21882 15 Pilot Lamp Red 22149 16 Pilot Lamp Clear 22148 19 Drain Copper Tube Part A 21286 20 Lid Hinge Rod Nuts 2 each 21737 21 Lid Knob Handle 21025 22 Lid Hinge Rod 22303 23 Handle Side 20237 Thermo Low Water Kit 20548 27 Wiring Internal Harness 61579 28 Stainless Wire Rack 22304 29 Drain Valve
13. oncentrations of chlorine that allow rusting to begin If allowed to accumulate on the heating element these deposits will lower the efficiency of the element and increase the power consumption of the unit 8 If you suspect that you have hard water you may need to change your water more frequently Salt deposits are an indication of hard water that will eventually cause rust 17 MAINTE NANCE Hydrocollator Mobile Heating Units Cleaning Tips 1 The interior of the unit should be cleaned usually every two weeks using a low abrasive bathroom cleaner Check for low or no chlorine content in your cleaner and make sure that the residue is thoroughly rinsed away with water 2 Astrong solution of vinegar and water will usually dissolve away deposits which then must be thoroughly rinsed away Care of HotPacs Always return the Hydrocollator HotPac to the hot water of the heating unit after each treatment There it is heated kept clean and ready for immediate use The HotPac may be boiled however this hastens the deterioration of the pack The pack may also be cleaned by scrubbing the pack with soap and water The simplified method of keeping the pack clean is to keep it immersed in water The Hydrocollator HotPac under constant daily use should have a useful life of at least one year When the pack begins to wear out the filler oozes and leaks through the fabric of the cloth and sections of the pack appear to be loose and empty and w
14. opper M 2 Part A 25010 Bracket Bulb Thermostat H20 S A Lo Water 2 Water Thief Spacer Thermostat Lo Water 2 Thermostat Lo Water Lamp Red Indicator Lo Water Fuse 6 3 Amp 2 Fuse Holder 2 Receptacle Power 8843 FSG W 40 60 Harness Wiring Tank Replacement with Drain Insert For neck Contour Packs Lid Rod Nuts 2 Lid Rod Valve Ball Fit Bib SS2 M2 M4 15 Part No 22245 10631 22146 23406 22304 21635 21259 20513 20237 22297 22087 21286 21023 21882 72393 20548 22147 71772 72734 74723 61579 23373 21053 21737 22303 21085 23392 REPLACEMENT PARTS N Hydrocollator Mobile Heating Units Model M 4 220 240 VOLT Low Water Cat No 2506 w packs Cat No 2508 w o packs Key 1 4 26 28 34 29 35 31 20 22 23 Part Description Element Heating 240 Volt 1500 Watt Thermostat Hydraulic Lamp Green 1607 5107 220 240 Volt Cord Set Country Specific Switch Rack Wire M 4 Hose Nylon 5 8 x 4 Coupled M F Caster 3 in 4 Handle M SS Lid Finished Lid Sub Assembly M 4 With Handle Cover Junction Box 18 25x19 125 M 4 Drain Copper M 2 Part A 25010 Bracket Element Support Water Thief Breaker Heinemann 2 Thermostat Lo Water Lamp Red Indicator Lo Water Receptacle Power 8843 FSG W 40 60 Tank M 4 Replacement with Drain Lid Rod Nuts 2 Lid Rod Valve Ball Fit Bib SS2 M2 M4 Bracket Bulb Thermostat H20 S A
15. ractice the precautionary and operating instructions Know the limitations associated with the Hydrocollator SS 2 M 2 M 4 Heating Units Observe the cautionary and operational decals installed on the unit e The thermostat is extremely sensitive and the slightest adjustment will alter the temperature several degrees The recommended operating temperature is 160 F to 166 F 71 to 74 C The temperature of the water should be checked with a thermometer after every adjustment before using the HotPacs Always allow sufficient time for the water temperature to stabilize e Always keep the water level over the top of the HotPacs to avoid burning or scorching of the packs e Never allow the HotPacs to dry after use e Check water level daily as it has a natural loss due to evaporation PRECAUTIONARY INSTRUCTIONS Hydrocollator Mobile Heating Units N CAUTION e Never adjust the thermostat too high The thermostat is extremely sensitive to the slightest adjustment e Clean the tank periodically as described in the maintenance portion of this manual e Always replace Hydrocollator HotPacs as soon as they show signs of wear e If the unit is to be left unattended for a period of time unplug the unit remove the packs empty the water and clean the tank e Do not move the Hydrocollator while filled with water Tipping over could result in burns to the user or others e Always unplug the Hydrocollator from the power source before a
16. rocollator SS 2 M 2 and M 4 Heating Units In order to obtain maximum life and efficiency of the Hydrocollator Heating Units please read this manual thoroughly and follow all instructions prior to operating the unit Specifications put forth in this manual were in effect at the time of publication However owing to Chattanooga Group s policy of continual improvement changes to these specifications may be made at any time without obligation on the part of Chattanooga Group PRECAUTIONARY DEFINITIONS Hydrocollator Mobile Heating Units The precautionary instructions found in this section and throughout this manual are indicated by specific symbols Understand these symbols and their definitions before operating this equipment The definitions of these symbols are as follows CAUTIONS Text with a CAUTION indicator explains possible safety infractions that could have the potential to cause minor to moderate injury or damage to equipment WARNINGS Text with a WARNING indicator explains possible safety infractions that will potentially cause serious injury and equipment damage DANGERS Text with a DANGER indicator explains possible safety infractions that are imminently hazardous situations that would result in death or serious injury NOTE Throughout this manual NOTE may be found These notes are helpful information to aid in the particular area or function being described N CAUTION e Read understand and p
17. t Nut 1 2 20 Brass and Overtemp Thermostat 26 12 REPLACEMENT PARTS Hydrocollator Mobile Heating Units Model M 4 Standard Cat No 2502 w packs Key Part Description Part No 1 Heating Element M 4 120 Volt 1000 Watt 20570 4 Hydraulic Thermostat 10631 5 Brkt amp Bulb Thermostat A B Assembly 2 each 21023 6 Lid 22348 7 Caster 3 in 21260 9 Junction Box Cover 22360 11 Power Cord 20568 14 Hose Drain 21635 15 Pilot Lamp Red 22149 16 Pilot Lamp Clear 22148 19 Drain Copper Tube Part A 21286 20 Lid Hinge Rod Nuts 2 required 21737 21 Lid Knob Handle 21025 22 Lid Hinge Rod 22361 23 Side Handle Serial Above 5149 20237 Thermo Low Water Kit 20548 Zi Wiring Internal Harness 61579 28 Rack Stainless Steel 22374 29 Drain Valve Ball 1 2 in Replacement 21085 30 Drain Hose Bib 23392 31 Replacement Tank M 4 22343 32 M 4 Outer Jacket 23384 34 Handle Lid Kit 22171 35 Water Thief 21882 36 Bracket Element Support 2 each 22356 26 On Off Switch 23406 Key numbers refer to Nomenclature section pages 5 and 6 Used to hold the Hydraulic Thermostat and Overtemp Thermostat to the Heating element Includes Gasket Thermostat Nut 1 2 20 Brass and Overtemp Thermostat 26 13 REPLACEMENT PARTS Hydrocollator Mobile Heating Units Model SS 2 220 240 VOLT Low Water Cat No 2307 w packs Cat No 2309 w o packs Key 1 4 26 28 23 34 29 35 15 27 31 20 22 29 Part Descript
18. tified Company service agent Defects or damage caused by labor furnished by someone other than Company the selling dealer or a certified Company service agent Any malfunction or failure in the Product caused by product misuse including but not limited to the failure to provide reasonable and necessary maintenance or any use that is inconsistent with the Product User s Manual COMPANY SHALL NOT BE LIABLE IN ANY EVENT FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you To obtain service from Company or the selling dealer under this warranty 1 A written claim must be made within the warranty period to the Company or the selling dealer Written claims made to the Company should be sent to 4717 Adams Road P O Box 489 Hixson TN 37343 USA Telephone 423 870 2281 USA Telephone 800 361 3661 Canada Outside USA 1 423 870 7200 Facsimile 423 875 5497 2 The Product must be returned to the Company or the selling dealer by the owner This warranty gives you specific legal rights and you may also have other rights which vary from state to state The Company does not authorize any person or representative to create for it any other obligation or liability in connection with the sale of the Product Any representation or agreement not contained in the warranty shall be void and of no effe
19. ttempting to empty water from unit e Always use factory authorized replacement parts e Always destroy and replace HotPacs which are exposed to contamination hazardous or cleaning materials bodily fluids mold etc A WARNING e Grounding the Hydrocollator SS 2 M 2 and M 4 Mobile Heating Unit Make certain the unit is electrically grounded by plugging into a hospital grade electrical outlet with a ground terminal receptacle U ground outlet 120 VAC only Follow the National Electrical Code e The water temperature in the Hydrocollator is approximately 160 F 71 C and the water scalding temperature is approximately 120 F 49 C SN Risk of explosion if used in the presence of flammable anesthetics Explanation of Symbols ATTENTION Consult accompanying documents TypeB equipment Denotes the degree of protection against electric shock particularly regarding allowable leakage currents and the reliability of the protective earth connection NOMENCLATURE WHITE LAMP where applicable when illuminated indicates that main power is connected the switch is on and unit is operating RED LAMP where applicable when illuminated warns of an overheat low water condition Action is necessary to correct the condition GREEN LAMP 220 240 volt units when illuminated indicates that main power is connected the switch is on and unit is operating drocollator Mobile Heating Units EHATTANOOOA White Lamp

Download Pdf Manuals

image

Related Search

Related Contents

Polaroid XS100  StarTech.com 50cm Internal Serial Attached SCSI Mini SAS Cable - SFF8087 to 4x SFF8482  CH10 Convector Heater User Manual CH10 Convector Heater User  INSTRUCTION BOOKLET  WEATHERPROOF DOME CAMERA Series SPU  NewerTech NWTU3NVSPATA  GB Stirling Engine Kit HB11-AS2 F Boîte de construction – moteur  Europa 250 DK Europa 250 DKL  MANUAL DEL USUARIO CORTACÉSPED  お客様へのお願し  