Home
User Manual
Contents
1. Energy Saving modes press and hold the Energy Save up button on the electronic controller faceplate To change the default times for automatic switching between Normal mode and Energy Saving mode follow the procedures below To change the time between Normal and Energy Saving modes 1 Press and hold the set button for 3 seconds until PS is T pm shown on the display indicating entry into the controller m settings menu aJ 2 Press the down button to scroll the menu until r6 is shown on the display The r6 value is the time in hours without the door i being opened When this time is reached during store ry w closing hours or quiet periods the electronic controller will switch the chiller from Normal mode to Energy Saving mode The r6 value must be 21 hour IMPORTANT Do not set r6 to O 3 Press the set button The current r6 value in hours is shown on the display 4 Press the up or down button to increase or decease the value in hourly increments 5 Press the set button to temporarily save the new r6 value 6 Press the down button to scroll the menu until r7 is shown on the display pm The r7 value is the maximum time in hours that the chiller will stay in Energy Saving mode When this time f J is reached the electronic controller will switch the chiller from Energy Saving mode to Normal mode 7 Press the set button The current r7 value
2. in hours is shown on the display 8 Press the up or down button to increase or decease the value in hourly increments 9 Press the set button to temporarily save the new r7 value 10 Press and hold the set button for 3 seconds to permanently save the new values and exit the controller settings menu Lights When in Normal mode the cabinet lights are on When in Energy Saving mode the cabinet lights are off Press the Light button on the electronic controller faceplate to manually switch the cabinet lights on and off 13 SKOPE BME ActiveCore Door Switch Temperature Setpoint Each door is fitted with a door switch which tells the electronic controller when the door is opened and closed If the door is opened for over two minutes an alarm will sound Press the set mute button on the electronic controller to mute the alarm The chiller temperature setpoint is factory set at 2 5 C for storage of perishable products all shelves maintain temperatures below 5 C The cabinet setpoint can be adjusted between 1 C and 15 C for other specialist applications if required see below SKOPE do not recommend that the setpoint be changed unless it is absolutely necessary and then only by small increments at a time To view and adjust the temperature setpoint 1 Press and hold the set button for 3 seconds until PS is T m shown on the display indicating entry into the controller settings menu aJ gm 2
3. Press the up or down button to scroll the menu until St I J J is shown on the display Ey uum P wu 3 Press the set button The current setpoint value is shown on the display 4 Press the up or down button to increase or decease the setpoint value to the required temperature 5 Press the set button to temporarily save the setpoint value 6 Press and hold the set button for 3 seconds to permanently save the setpoint value and exit the controller settings menu Messages and The following table explains messages and alarms that the electronic Alarms controller displays 14 Display Description ll Message The chiller is in Normal mode and the electronic J controller displays the chiller temperature qur om Message The chiller is in Energy Saving mode When in Energy Saving mode the temperature inside the chiller is qm m um moderated and the cabinet lights turn off The lights can be f switched on and off by pressing the light button on the we ue uer controller faceplate and the chiller can be switched into normal mode by pressing the Energy Saving button on the electronic controller faceplate Alarm The front door has remained open for over two minutes an em em An alarm sounds and the compressor and evaporator fan turn CSCI of Lil a Alarm Probe failure A temperature probe has failed and an m alarm sounds Contact a service agent J uu mm Alarm There is a re
4. lt Sudns verdes Sade vns s deos S meee ee 18 Troubleshooting 1 0 0 0 0 eee es 19 SKOPE BME ActiveCore 1 Installation Safety First Always observe safety precautions when using any electrical appliance Read these instructions carefully and retain them for future reference o When the appliance is used by or near young children or infirm persons close supervision is necessary especially to ensure children do not play with it Do not use this appliance for other than its intended use Do not cover the grilles or block the entry or exhaust of airflow by placing objects up against the refrigeration unit Do not probe any opening Only use this appliance with the voltage specified on the cabinet rating label affixed to the refrigeration unit o Ensure the appliance has adequate ventilation as this is essential to economical high performance Be careful not to touch moving parts and hot surfaces For your own safety and that of others ensure that all electrical work is done by authorised personnel n Ifthe power supply flexible cord becomes damaged it must be replaced by an authorised service agent or similarly qualified person in order to avoid a hazard n Ensure all necessary safety precautions are observed during installation or removal of the refrigeration unit o The appliance is not designed to be stable while in motion Use extreme caution when moving or transporting it n Do not store explosive substanc
5. moved into position so that it is not trapped behind the cabinet Ensure there is always at least a 50mm gap around the back top and underside of the cabinet Keep the ventilation slots in the lower front panel clear at all times Never store cardboard cartons or other objects in front of the chiller CAUTION To prevent over heating and conserve energy ensure air flows freely all around the chiller including front back top and underside minimum 50mm gap Ensure both rear spacers are fully extended outwards and locked into place This will provide the necessary air gap at the rear of the cabinet for correct operation Back of chiller Rear spacer SKOPE BME ActiveCore Door Handles Fitting Door For transit purposes the door handles may be packed separately inside the Handles cabinet If the door handles are packed separately follow the steps below to fit them to the door s To fit a door handle 1 Remove the handle s from inside the cabinet by carefully cutting the cable ties securing the handle and remove the packaging 2 A metal spring clip is fitted inside the handle mounts at each end of Spring clip the handle pointing up Rotate the handle so that the spring clips point up Bracket 3 Locate both of the handle mounts onto the Frontot brackets on the front of door the door and push the handle down onto the Handle brackets until an audible click is heard and the handle locks into p
6. on the product e Applies any other trade mark to the product e Adds to the product any written material that is likely to damage the reputation of the trade mark Notice of the above contractual obligations passes to e Successors or assignees of the buyer Future owners of the product BME ActiveCore SKOPE Bottom Mount Vertical Chiller User Manual MAN11080 Rev 3 2 Oct 2015 2015 SKOPE Industries Ltd All rights reserved SKOPE and the SKOPE logo are registered trade marks of SKOPE Industries Ltd ActiveCore and the ActiveCore logo are trade marks of SKOPE Industries Ltd
7. the chiller between Energy Save and Normal mode Set mute Button Press to mute the alarm Press and hold to access parameters Light down Button Press and hold to switch the cabinet lights on and off Defrost Indicator ON when the defrost is activated Flashes xL when the activation of the defrost is temporarily delayed due to procedures in progress Compressor Indicator ON when the compressor and condenser fan starts Flashes when activation of the compressor is temporarily delayed Fan Indicator ON when the internal cabinet fans are SA activated Flashes when activation of the fans is temporarily delayed D Alarm Indicator ON when alarm is signalled Operation User Manual SKOPE BME ActiveCore Normal and The electronic controller is programmed to run the chiller in Normal mode Energy Saving or Energy Saving mode Operation User Manual Modes When plugged in the chiller will run in Normal mode If the front door s are not opened for a specified time period default setting is three hours the electronic controller will switch the chiller from Normal mode to Energy Saving mode and the cabinet lights will turn off The electronic controller will switch the chiller back into Normal mode when a door is opened or after a specified time period default setting is nine hours in Energy Saving mode To manually switch the chiller between Normal and
8. the door Operation 11 User Manual SKOPE BME ActiveCore 12 Introduction Faceplate Electronic Controller The chiller is fitted with a Carel S4 electronic controller which is visible through a cutout in the cabinet front panel The electronic controller is pre programmed and requires no initial setup or additional programming SKOPE does not recommend that the settings be changed unless it is absolutely necessary CAUTION The electronic controller must only be adjusted by an authorised service agent To achieve energy efficient operation the electronic controller uses temperature probes and door switches to monitor chiller usage and switch the chiller between Normal and Energy Saving modes control and display the chiller temperature collect data signal temperature alarms and force a defrost cycle when required Because the electronic controller plays such an important role it s helpful to know the parts of the faceplate you may use 6 8 1 2 No Mem Description Digital display of cabinet temperature or messages The T temperature is what the sensor inside the chiller detects and 1 LLL not necessarily the product temperature However they may E J be very close depending on how the controller is set to sense temperature Energy Save up Button Press to view the current chiller mode ECO Energy Saving and nor Normal Press and hold for 3 seconds to switch
9. 17 Contact an authorised service agent to replace it Contact an authorised service agent to replace it Clean or replace the condenser filter see page 16 Clean the condenser see page 16 Ensure the cabinet is in a cool spot see page 5 Ensure the cabinet has good ventilation around the refrigeration unit see page 5 Ensure doors are closed more often Ensure product is not blocking airflow slots Ensure there is space around individual product pieces Clean or replace the condenser filter see page 16 Clean the condenser see page 16 Ensure the cabinet has good ventilation around the refrigeration unit see page 5 19 SKOPE Contacts SKOPE Industries Limited NEW ZEALAND CONTACT Head Office PO Box 1091 Christchurch New Zealand Freephone 0800 947 5673 Fax 03 983 3896 E mail enquiry skope co nz Website www skope co nz AUSTRALIAN CONTACT A B N 73 374 418 306 PO Box 7543 Baulkham Hills B C NSW 2153 Australia Freephone 1800 121 535 Fax 1800 121 533 E mail enquiry skope com au Website www skope com au Trademark Infringement The SKOPE trademark on this product is infringed if the owner for the time being does any of the following e Applies the trade mark to the product after their state condition get up or packaging has been altered in any manner Alters removes including part removal or obliterates including part obliteration the trade mark
10. User Manual MAN11080 Rev 3 2 Oct 2015 BME ActiveCore SKOPE Bottom Mount Vertical Chiller BME1200 AC SKOPE Warranty Protection Register now for peace of mind It s quick and simple Take a few minutes to register your SKOPE product and enjoy more efficient support plus other warranty benefits When registering make sure you have your cabinet serial number at hand To register online Visit our website at www skope com warrantyprotection then complete and submit the online registration form Or freephone 1800 121 535 Australia 0800 947 5673 New Zealand SKOPE 1 year Extended Warranty Extend your Warranty Protection by 1 year during registration Please check you have not already organised an extended warranty through your dealer at time of purchase For pricing information on an extended warranty visit www skope com warrantyprotection Service amp Support We know you will get years of satisfaction from your new SKOPE product when you follow a few simple preventative maintenance guidelines Helpful information is available on our website www skope com serviceandsupport Thank you for purchasing a SKOPE refrigeration product SKOPE BME ActiveCore User Manual CONTENTS 1 Installation Safety First e sms mue donc y Rx edm Gu scm ened 4 Positioning the Cabinet 0 0 00 00 ce eee 5 Climate Class 0 0 0 0 cc eens 5 Chiller Location 0 0 0 0 cee ee eee 5 ge RPM Tr 5
11. alie s ceases oe od pee ee Ane eae ee eae tees 5 Before Operating nnana anaana ce eee ees 5 Door Handles 0 0 eee ene 6 Fitting Door Handles 0 0 0 cc ee 6 Removing Door Handles 0 0 000 7 DNGIVES escrip ida eG Roa cose REE Bae See eee aces 8 Shelf Clips llle eee 8 Repositioning Shelves llle 9 2 Operation Automatic Start Up 0 0 0 0 es 10 LIQHUNG 222626 ds oecendedee dn durdes eeetesesdaeewe eee bas 10 LED Tube Side Light 0 0 0 cee ees 10 LED Modular Shelf and Side Lighting 10 SIS BIOL s 3 eode oo ord ge dee uh eed dade DRESS PE PEE 10 Loading PITOGUGCL iare ke dri drm RoRELE SAO A EGHE TRES UR eee ox 11 Electronic Controller lille 12 IIFOGHC IDE uu sse qmedukduETTIMEUUeSUOEOSIVg Edd cea aes 12 FACS DIGS aru sin ao ew Hac bree eee ol IG ae E wig pee 12 Normal and Energy Saving Modes 13 Ely cd T 13 Door Switch 2 0 0 eee es 14 Temperature Setpoint 0 0 0 0 0c ec eee 14 Messages and Alarms 0 00 eee ees 14 3 Servicing Isolating Electrics 2 0 0 0 cc eas 15 CICAMING ET 16 Capel qM 16 Condenser Coil amp Filter 2 2 0 ee 16 Bienne P Gp oh ak a hoe ae ea ee a eee eee e A 18 LED Tube Side Lighting 0 0 0 ccc eee ees 18 LED Modular Shelf and Side Lighting 18 SIg BIO sacac
12. d shelves unload and remove the shelf Shelves establish the desired position and slide the shelf clip in each of the shelf support strips to the desired position see To slide a shelf clip up and down on page 8 Sit the shelves on the shelf clips When repositioning shelves fitted with shelf lights the height is adjusted as per normal with the shelf clips The shelves can be repositioned as far as the shelf light cable reasonably allows via the fixed cut out in the side channel cover see procedure below To reposition shelves fitted with lights 1 Isolate the chiller from the power supply see Isolating Electrics on page 15 2 Remove product from the shelf required to be moved and from the shelf immediately above it 3 Establish the desired shelf position 4 Support the weight of the shelf and lift it up off the shelf clips Be careful not to damage the connected shelf light cables running through the front shelf clips 5 Slide the shelf clip in each of the shelf support strips to the desired position see To slide a shelf clip up and down on page 8 The shelves can be repositioned as far as the shelf light cable reasonably allows 6 After the shelves have been securely positioned connect cabinet to the power supply and check for correct operation 7 Reload the shelves with product Installation 9 User Manual SKOPE BME ActiveCore 2 Operation LED Tube Side Light LED Modular S
13. es such as aerosol cans with a flammable propellant in this appliance n Please contact SKOPE Customer Services for advice regarding disposal of this appliance CAUTION Never overload the power supply which could damage the chiller and product See the rating label inside the cabinet for the safe power supply and current draw WARNING Always disconnect the chiller from the mains power supply before cleaning or maintenance A Installation User Manual Climate Class Chiller Location Power Cord Ventilation Before Operating Installation User Manual SKOPE BME ActiveCore Positioning the Cabinet The chiller is designed to operate within a climate class 5 environment 40 C 40 RH We recommend that you put the chiller in the coolest place possible because it will use less power and last longer The location of the chiller may be the single most important decision that will extend its life and ensure economical high performance Allow adequate space for the door s to open and close properly Self closing doors have internal torsion bars pretensioned at the factory Ensure the cabinet sits on a level surface so that the door shuts and correctly seals and that the doors are unobstructed Level footing also prevents the condensate tray from overflowing The chiller has a flexible power cord fitted with a 3 pin plug which exits the rear of the cabinet at floor level Locate the power cord before the cabinet is
14. frigeration system error and the controller t turns the chiller off to avoid damage An alarm sounds and the cm J compressor and evaporator fan turn off Contact a service agent Operation User Manual SKOPE BME ActiveCore 3 Servicing Isolating Electrics The chiller MUST be isolated from the power supply before attempting any maintenance Either unplug the cabinet from the wall or use the isolation switch to turn off electrics to the cabinet and refrigeration unit The isolation switch is located behind the cabinet front kick panel on the right hand side of the refrigeration unit compartment To isolate the electrics 1 Open the door and undo the fixing screws from the top of the front kick panel Pull the kick panel out to remove Note The electronic controller is attached to the front kick panel Take care of cables when removing the front kick panel Door open Isolation switch Electronic controller Front kick panel removed 2 Switch off O the power at the isolation switch located on the right hand side of the refrigeration unit compartment 3 Once the maintenance work has been completed remember to turn the isolation switch back on I before refitting the front kick panel Servicing 15 User Manual SKOPE BME ActiveCore Cabinet Condenser Coil amp Filter 16 Cleaning Periodically wipe the inside and outside of the cabinet with a damp cloth taking care to keep moistu
15. he following table Possible Cause Suggestions Problem Cabinet not operating No controller display e Light not on Power consumption is higher than expected e Product is too warm Warm cabinet temperatures Compressor operating for long periods more than 1 hour Servicing User Manual Loss of power supply solating switch turned off e Controller alarm Loss of power supply solating switch turned off Electronic controller displays ECO indicating the chiller is in Energy Saving mode Lights switched off Failed LED tube Failed LED shelf light Blown cabinet fuse unit operating too hot Cabinet doors are opened excessively Restricted airflow to cabinet e Blocked condenser Poor ventilation around refrigeration unit e Check mains power supply e Check isolating switch is turned on I see page 15 Refer to Messages and Alarms on page 14 Check mains power supply e Check isolating switch is turned on I see page 15 Switch the light on while keeping the chiller in night mode by pressing the ight button on the electronic controller faceplate Change the chiller into normal mode by pressing and holding the Energy Saving button on the electronic controller faceplate or open the door Switch light on by pressing the light button on the electronic controller faceplate Replace LED tube see page
16. helf and Side 10 Lighting Sign Light Automatic Start Up After the cabinet has been positioned in a suitable place plug it in and check the following activity Item Activity An electronic controller runs the chiller and is visible behind E ectrahie the front panel The display panel first flashes start up Controller Em messages before stabilising on the cabinet temperature nw The lights that illuminate the sign and cabinet interior will come Lighting on approximately five seconds after the chiller is turned on The compressor and condenser fan will start approximately one minute after the chiller is turned on To verify listen for the compressor and check that the Compressor and COMPRESSOR light is lit on the electronic controller The Condenser Fan compressor and condenser fan will turn off when the product temperature reaches around 2 C and on again when it reaches about 4 C SKOPE BME ActiveCore default settings The evaporator fan starts approximately three seconds after Evaporator Fan the compressor and condenser fan To verify check that the FAN light is lit on the electronic controller Lighting The cabinet interior lighting will consist of either LED tube side lights or LED modular shelf and side lighting The cabinet may also be fitted with a top sign assembly which is lit by an LED tube The cabinet lighting will automatically switch on and off depending on chiller usage The lights can al
17. il it is anse Aff released from the 41r aluminium housing and then push the diffuser out of the way E LED Tube 3 Rotate the LED tube until the pins on the ends of the tube align with the slots then slide it out Lamp holder Pins NI C MOL f B the LED tube is fitted with the Power end at the top usually marked POWER or similar Note If present LED tube the pointer at each end of S the tube should be set to the 0 position SS 5 Refit the diffuser by slipping the back section into the housing then squeezing and snapping the front section of the diffuser into place as you work down the length of the light ZZ ZN Cabinets with LED modular shelf and side lighting are lit by LED shelf lights mounted on the front of the shelves two lights per shelf and LED side lights LED modular light components are all non serviceable items and must not be tampered with in any way If a component is suspected of being faulty a service call should be arranged so that a replacement component can be fitted BME600 AC and BME1200 AC chillers are fitted with a lit sign In the event of sign light failure a service call should be arranged so that a replacement LED tube can be fitted Servicing User Manual SKOPE BME ActiveCore Troubleshooting For questions about the electronic controller see page 12 For problems with the cabinet and refrigeration unit use t
18. lace Bracket If the handle does not lock into place check the orientation of the handle and try again If only one end of the handle locks into place follow the steps over the page to remove the door handle and refit ensuring both of the handle mounts are located onto the brackets before pushing the handle down and locking into place 6 Installation User Manual SKOPE BME ActiveCore Removing The door handles can be removed for transporting and moving the cabinet Door Handles through doorways Installation User Manual To remove a door handle 1 Open the door and peel back the door gasket from behind the handle mounts on the inside of the door frame Unscrew the handle mounts through the holes on the inside of the door frame and remove the handle Handle Remove the bracket s from the handle mount Handle mount by pressing the bracket in and down until it unclips from the handle mount Bracket Fit and screw the bracket s back onto the door Ensure the catches are pointing up as Bracket pictured Catch Catch Refit the door gasket by clipping it back into place on the inside of the door frame If the gasket is out of shape after refitting it a hair drier can be used to heat and reshape it SKOPE BME ActiveCore Shelf Clips Shelves The chiller is fitted with wire shelves which may be positioned at different heights to suit various products and solid bottom shelf ves Solid bot
19. oops facing out Then clip the into the slots on the bottom face of the front kick panel vent Servicing User Manual Servicing User Manual SKOPE BME ActiveCore To clean the condenser coil 1 Remove the front panel and isolate the chiller from the power supply see Isolating Electrics on page 15 2 Brush the condenser coil with a soft brush to remove any dust and fluff T LM lt a Condenser coil 3 Turn the isolation switch back on I and refit the front panel 17 SKOPE BME ActiveCore Lighting This chiller is designed for use with LED tube lights and is not compatible with fluorescent tubes IMPORTANT DO NOT use fluorescent tubes LED Tube Side LED tube side lit cabinets are lit by one or two T8 LED tube side lights which Lighting LED Modular Shelf and Side 18 Lighting Sign Light 4 Fita new LED tube Ensure can be replaced without moving shelves or product See the table below for light tube specifications Interior light tube specifications Item Description Interior light Eco Point 20 Watt T8 LED tube 226mm x1350mm To replace an LED tube side light 1 Remove the front kick panel and isolate the chiller from the power supply see page 15 2 Remove the diffuser by squeezing it unt
20. re away from electrical parts As with any maintenance ensure the chiller is isolated from the power supply before cleaning To ensure trouble free performance we strongly urge monthly cleaning with a soft brush to remove dust and fluff A more thorough cleaning is required by qualified service personnel every six months The condenser and filter must be kept clean for efficient and reliable operation The condenser coil is located on the front of the refrigeration unit The optional filter is located on the front panel in front of the condenser coil The optional filter is disposable and should be replaced when it shows signs of wear Do not apply hot water blow dry or place in dishwasher WARNING Isolate the chiller from the power supply before cleaning the condenser coil see page 15 To clean the optional filter 1 Rotate the grille at the bottom of the front kick panel out to gain access to the filter Front kick panel grille Front kick panel grille rotated out 2 Toremove the filter use the finger loops to pull the filter up and detach from the front kick panel Finger loop 3 Clean the filter with a vacuum cleaner wash with cold water and shake excess water off before refitting Do not apply hot water blow dry or place in dishwasher If necessary discard and refit new air filter 4 To refit the filter insert it up into the front kick panel vent with the finger l
21. so be manually switched on and off using the light button on the electronic controller faceplate see page 12 Cabinets with LED tube side lights are fitted with LED tube s which can be replaced without moving shelves or product see page 18 for replacement instructions Cabinets with LED modular shelf and side lighting are lit by shelf lights mounted on the front of the shelves two lights per shelf and LED side lights LED modular light components are all non serviceable items and must not be tampered with in any way If a component is suspected of being faulty a service call should be arranged so that a replacement component can be fitted Cabinets with a lit sign are fitted with an LED tube located inside the top sign assembly In the event of sign light failure a service call should be arranged so that a replacement LED tube can be fitted Operation User Manual SKOPE BME ActiveCore Loading Product Let the chiller run 30 minutes before loading it with product the first time When loading the shelves with product o Allow adequate air space around each item to ensure even cooling and efficient operation of the chiller Do not exceed a maximum load of 20kg per shelf Remove some product if the shelves are flexing Do not let anything overhang the shelves because this might stop the doors from shutting or even break something For security there is a lock bracket above the door where you can attach a padlock and secure
22. tom shelves are held in place by brackets attached to the floor of the chiller It is important that solid bottom shelf ves are always in place as they direct the interior air circulation IMPORTANT For correct chiller operation the bottom shelf ves must always be in place at the bottom of the chiller Interior shelf lit cabinets incorporate cabinet interior lights on the front of each shelf see LED Modular Shelf and Side Lighting on page 10 Each wire shelf is held in place with four shelf clips which engage in the shelf support strips and slide up and down to the desired shelf position The support strips are numbered for easy location of shelf clips View the numbers in the bottom LH corner of the shelf clip To fit a shelf clip 1 The shelf clip twists onto the shelf support strip Position the shelf clip with the flat side up against the shelf support strip and the two prongs pointing up Twist the top Shelf clip of the clip anticlockwise onto the shelf support Shelf strip until it locks in support place strip To slide a shelf clip up and down 1 Pull the shelf clip tab up and slide the shelf clip up or down as required Once in position ensure the shelf clip is locked into place To remove a shelf clip 1 Pull the shelf clip tab up and twist the top of the clip clockwise off the shelf support strip Installation User Manual SKOPE BME ActiveCore Repositioning When repositioning standar
Download Pdf Manuals
Related Search
Related Contents
EVB-LAN9730-MII Evaluation Board User Manual - SMSC USER`S MANUAL MEDIUM WAVE SYSTEMS Variador de velocidad 160 SSC™ (Serie C) Skil 2487 Drill User Manual projeto - Centro Regional do Nordeste Copyright © All rights reserved.