Home

SiteScanner 13.1 Quick Start Guide

image

Contents

1. 17 KNOWN ISSUES RELATED SITESCANNER 1 3 20 Motorola SiteScanner 13 1 Quick Start Guide Page 2 of 21 Recommended System Requirements To effectively use this application the following computer platform is recommended e Intel Pentium 4 1 5 GHz or better or equivalent e Microsoft Windows XP SP2 Windows Vista 32 and 64 bit or Windows 7 32 and 64 bit e Microsoft Word XP Word 2002 or later required for generating Reports e GB minimum e 500 MB free disk space for installation e 1024x768 VGA with true color e Mouse trackball or compatible pointing device with scroll wheel e Microsoft Internet Explorer 6 0 or later e CD ROM drive Support for Wireless Measurement via RF Monitoring Mode In order to enable data collection via RF Monitoring mode you will need one of the WLAN client cards that support Motorola s custom driver The latest list of supported WLAN cards is available online at http support symbol com support product RFDesignandPlanning html Installation on Win XP Win Vista or Win 7 Installing SiteScanner is much like installing any other Microsoft Windows software However SiteScanner uses electronic license control so an extra activation step will be required
2. gt 60 00 dBm 44 2 6415 29 gt 70 00 dBm 34 5 5005 22 Q gt 80 00 dBm 0 5 75 35 sq gt 30 00 dBm 0 0 0 00 sq fe gt 100 00 dBm 0 0 0 00 sq 8 gt 11000 dBm 0 0 0 00 sq 8 lt 110 00 dBm 0 0 0 00 sq fe Partition Categories Bl or sheetrock Cubicle wall wooden door Elevator or metallic obstacle Glass door or window no doping ll Brick concrete or concrete bloc Basement or foundation wall Metallic rack Project Training gt gt Floor 4 29 85 34 35 3 88 SNAP GRID ORTHO POLAR OSNAP OTRACK DUCS DYN LWT MODEL gt I E A fit O Step 3 If you took measurements the 802 11 standard in addition to 802 11b g n click on the pull down tab next to Standard and select 802 11 The Heat map visualizations for the 802 11 standard should now appear IEEE S02 11b g n IEEE S z 11a n IEEE SU 11b o n Auto Refresh Step 4 Click Exit to close the Display Options window pane Standard Floor Signal dBm Motorola SiteScanner 13 1 Quick Start Guide Page 16 of 21 What s New in SiteScanner 13 Version 13 1 This release supports the RF modeling for the following Access points 8132 7161 AP6521 AP6522 AP621 AP622 The support for RF Design amp Planning Software Suite is moved from www onepointwireless com rfdesign to http support symbol com support
3. for Technical Support Asia Pacific 001 631 738 6213 For international callers outside the US For additional support contact options visit http www motorola com Business US EN Support Support Contacts Motorola SiteScanner Quick Start Guide Page 21 of 21
4. right click in the drawing window and go to Exit To pan the drawing file so md that you can take a measurement in a certain location of the map click on the icon Left click hold Motorola SiteScanner 13 1 Quick Start Guide Page 14 of 21 the mouse button with the cursor the drawing window Move the mouse the direction you wish to pan to To exit Pan mode right click in the drawing window and choose Exit Step 11 When you are done taking measurements click the Exit button Visualizing Your Measurement Data Step 1 Select the Measurement Survey menu gt Visualize Survey Data to bring up the heat map visualizations If a Warning dialog box pops up click OK and proceed The Display Options window pane will appear to the left of the drawing window Reports Utilities Help Configure Scan Settings Configure Authorized List Visualize Visualization Options 4 Import Measurement Data Export Measurement Data Delete Measurement Data Marker Settings Access Point Associations Step 2 You should now see a heat map being displayed in the drawing window To change the type of heat map being displayed click on the pull down menu next to Map and choose from the list For an explanation of what the different heat map visualizations mean please refer to Visualizing Survey Data in Chapter 3 Measurement Surveys in the SiteScanner User Manual IMPORTANT NOTE If the Heat maps
5. do not appear the two possible reasons are 1 you are trying to visualize for the wrong Standard a n or b g n or 2 no APs were found on the Standard you were scanning for Motorola SiteScanner 13 1 Quick Start Guide Page 15 of 21 Motorola SiteScanner C Program Files SiteScanner W orks paces Default Defautt_Final dwg 9 Drywall or sheetrock Floor4 wz amp 22 5 Qe a A 7 a 3 H Display Options Map Coverage v Filter Measured Values Filter By SSID Guest 00 12 DA D1 ES F 7 Highway 61 00 15 C7 DB EB 20 00 17 0E 0 amp D1 70 02 16 6F 00 00 48 Kirila 00 06 25 7B 00 47 C linksys 00 0C 41 18 9E 16 linksysR 73c155 00 0 66 79 1 55 C LSw Guest 00 17 0E 0 amp D1 71 00 15 C7 DB EB 21 7 mark 00 11 95 0B EA BE C nhaustin 70013 10 8 5 7 pinkdragon 00 14 BF B6 D7 EC 7 Symbol Eng BG 00 A0 F8 BB F5 50 7 Symbol Port41 A73 00 40 F8 6E 55 4D 00 A0 F amp BB FA 19 C 00 40 F8 BB FE 01 v wee 00 14 69 F2 B0 30 00 14 64 07 F1 90 Standard IEEE 802 11b g n Floor 1 04 Signal 120 Auto Refresh agi 5 x Q MOTOROLA o _Model_ Layout Layout2 Legend Data AP Predictions Grids gt 50 00 dBm 20 7 3003 13
6. prod uct RFDesignandPlanning html Many external antennas are also supported along with the bug fixes Please refer to Release Notes for more details O O O Qux Version 13 0 Enhancements General Improvements Motorola SiteScanner 13 1 Quick Start Guide Page 17 of 21 Added a product Start Page to provide up to date information on product announcements enable quick access to common operations and simplify the product licensing process Added a modeless general use building modeling panel for quick access to building modeling tools and options Added a quick access visibility toolbar Added a toolbar for changing the current floor Updated menu layout to improve usability Added support for blended color grid visualizations this is now the default view Added support for bitmap based grid visualizations All drawing data can now be saved into a single file format spz for easy transfer between systems and or upload to an ADSP server Building Modeling Added support for undo redo of building modeling operations Added the ability to cut copy paste building entities across floors Added RF Intelligent detection of wall overlap to increase future prediction accuracy during building modeling process Improved right click context menu options for quick access to building formatting options Added support for entity selection using a polygonal boundary Added support for rotating entities clockwise counte
7. 1 3 DO AD FS 6E 4B CO SYM DEY 00 03 52 E2 80 42 00 03 52 E2 80 43 00 03 52 E2 B2 70 00 03 52 E2 B2 71 00 12 D9 03 37 00 00 13 10 46 BF 27 00 13 19 31 8 00 13 5F 56 11 10 nn 197 cp c h 10 e n Remove MAC Remove Remove Step 9 You can begin taking measurements by clicking on points on the map that corresponds to your current location There are two options for recording data under the Mode section Single Marker mode records a single measurement point on the drawing file when you left click a point on the map Track Run mode records multiple points along a straight line which are collected and plotted between your start and end point clicks Track runs are continuously drawn unless you switch back to Single Marker mode If you wish to delete a measurement click on the Undo button For further explanations of these two modes please refer to Taking Measurements in Chapter 3 Measurement Surveys in the SiteScanner User Manual Mode Single Marker 0 Track Run Track Count MiA Total Marker Count 0 Center map on mouse click Specify marker location Vie visible Access Points Configure Authorized List Configure visible Data Exit Step 10 If you find that you are zoomed too far in or out click on the amp icon Left click and hold the mouse button while the cursor is in the drawing window and move the mouse up or down in order to zoom in or out When you are done
8. 20 of 21 custom driver to avoid possible system crashes The following steps can be taken to disable the firewall 6 Goto Start gt Run gt services msc 7 Double click the service named OfficeScanNT Personal firewall 8 In the dialog that appears change the Startup type to Disabled press Stop and click Ok 9 Start gt Control Panel gt Network Connections 10 Right click the Motorola measurements adapter and select Properties 11 In the dialog that appears uncheck the Trend Micro Common Firewall Driver in the list of available network components and press OK Installation may fail on some HP PCs A warning message regarding the software MSXML is given during the installation failure If this occurs please contact Motorola Wireless Software Support and a fix will be promptly supplied Installing the Motorola WLAN driver on a PC with the AirPCapN driver installed first may cause the PC to crash Reports sometimes fail to generate when using custom grid boundary regions When running the Utilities Reports command if Select Region from the Boundary tab is used to define a custom region then in some random cases the report may fail to generate successfully It is recommended that users select Entire Region in this dialog 1 800 653 5350 United States and Canada 55 11 4133 3180 South America 420 533 336 123 Europe the Middle East and Africa 1 800 457 439 Australia 65 6796 9600 select 2
9. 3 2 472 GHz 200 Ch 14 2 484 GHz 200 foe DOOR STIS Select All Select Mane Apply uniform dwell tine to all selected channels ms Update Receiver Height 4bove Floor 3 0 Feet Ww so Step 6 Select the desired WLAN adapter to perform the site survey If no adapter is listed ensure you have installed the custom driver or contact Motorola s wireless software support team at Ems support motorolasolutions com Motorola SiteScanner 13 1 Quick Start Guide Page 12 of 21 Select WLAN Adapter Step 7 A panel should now appear towards the bottom of the drawing window If there are any APs in the vicinity the list under the Visible Access Points section will start populating It is recommended that you let the Visible Access Points list refresh at least 5 times before proceeding this can be seen by periodic updates to the Visible Access Points list IMPORTANT NOTE If the Visible Access Points list does not populate and you are certain that there are active APs nearby click the Exit button You need to ensure that you are not associated to an AP under the Windows Wireless Network Connections Also if the laptop used to perform the site survey has an active internal wireless card try disabling the internal card and then proceed with using SiteScanner Motorola SiteScanner C Program Files SiteScanner Workspaces Defauli Wefault_Final dwg Gra y amp 7 OA oe Model
10. In order to install SiteScanner you will need your installation CD or installation executable downloaded from http support symbol com support product RFDesignandPlanning html and some way to transfer files to your PC or receive email directly on your PC IMPORTANT NOTE You will need to uninstall any previous versions of SiteScanner prior to installing the new SiteScanner unless you are applying an upgrade patch file As for your user data they will be backed up to a directory called UserBackup in the directory of the new installation of SiteScanner the default location IS C Program Files SiteScanner UserBackup Preparation It is very important to perform the following preparatory steps to ensure your installation goes smoothly e Administrative Privileges Are Required for Install a user with local administrative privileges must install SiteScanner Non administrative users may use the software once it has been installed e Internet Explorer 6 0 or better is required to properly run SiteScanner e Windows Service Packs Your software will work best running with the most recent updates of Windows These upgrades are available through the Microsoft Windows Update web site Motorola SiteScanner 13 1 Quick Start Guide Page 3 of 21 Installation procedure To install SiteScanner please follow these steps in the order presented 1 2 Step 1 Step 2 Step 3 Step 4 Close any programs running within Windows before s
11. Layout Layout2 Network Indicators S Single Marker Track Run Network Deployment Legacy Track Count Visible Access Points Total Marker Count 0 MAC Address 5510 Signal Strenath RSSI Channel E Standard Channel Accep 9A F3 A6 29 A9 EE Anthony Excellent 11 802 11 big Enabled Mo 19 5 84 93 87 Poor 1 802 11 big Enabled No 3E 05 12 0F 00 E0 Poor 7 802 11 big Enabled No 06 19 5E B4 93 87 HatZone Duo 1 Poor 1 802 11 b g Disabled Mo 00 40 F8 E9 36 18 M Wireless Excellent 11 802 11 big Enabled No 00 0 8 9 26 90 M Wireless Good E 802 11 a Enabled No 00 40 F8 E5 9F 34 SYM_DEV Poor 6 802 11 big Enabled No 00 0 8 1 3 80 M Wireless Poor 1 802 11 b g Enabled 00 40 F8 BB FA 18 SYM_DEV Excellent 1 802 11 big Enabled 00 0 8 04 SYM DEV Excellent 165 802 11 a Enabled 00 19 5E B4 93 87 Poor 1 802 11 big Disabled am am mA mA AA c Center map on mouse click Specify marker location View All Visible Access Points v Configure Authorized List Configure Visible Data 29 06 11 47 3 88 SNAP GRID ORTHO POLAR OSNAP OTRACK DUCS DYN LWT Annotation Scale 1 1 v Pi Step 8 After the list has been populated you now have the option to specify which APs are authorized unauthorized or rogues Authorized APs are APs that are part of your network Unauthorized APs are APs that you are aware of bu
12. NSE AGREEMENT Motorola is willing to license its Design and Management Software Solutions defined as Products below and the accompanying documentation to you only on the condition that vou accept all the terns in this License Agreement Agreement IMPORTANT READ THE FOLLOWING TERMS AND CONDITIONS gt Save As Prnt t don t accept this agreement Step 6 The wizard will begin searching for your new hardware Device Driver Installation Wizard Installing Motorola HF Measurement device Please wait while the drivers install This may take some time to complete i Cancel If you receive a warning message saying that the software you are installing has not passed Windows Logo testing click Continue Anyway Motorola SiteScanner 13 1 Quick Start Guide Page 6 of 21 Hardware Installation The software are installing for this hardware Motorola Netgear 5 111 802 11 Measurements Adapter has not passed Windows Logo testing to verify its compatibility with Windows Tell me why this testing is important Continuing your installation of this software may impair or destabilize the correct operation of your system either immediately or in the future Microsoft strongly recommends that you stop this installation now and contact the hardware vendor for software that has passed Windows Logo testing Continue Step 7 If the dialog indicates your hardware
13. OM DRIVER INSTALLATION FOR THE WLAN CLIENT 5 LICENSE AC TIVATION Mee 7 EEMNES EICENSE II E testa wae acne meu d daa eto vive cue AE SEO 8 LISING AN AUTHORIZATIONAGODE ROBORE ode S Quit 8 MEE ERIS on PO cup RE WE e MERE T 8 INTRODUCTION TO USING SITESCANNER nnne nena anna uan n nnne e aa RR RR RR RR OS SERA ERO S SR RR NR RR ESO aa 9 REQUIREMENTS tentus ocior et c I App Ad DLL c cine DTI DD DSL Qa OLEI 9 LOADING RASTER IMAGES RAW CAD FILES OR FORMATTED DRAWING 9 PERFORMING A SITE SURVEY ze Eo eara e nU ea 10 VISUALIZING YOUR MEASUREMENT 15 WHATS NEW IN SITESCANNER 3 X cec 17 MERSION 17
14. SiteScanner 13 1 MOTOROLA Quick Start Guide 72E 167673 01 Rev August 2012 Thank you for choosing SiteScanner from Motorola Please read the Quick Start Guide installation upgrade instructions prior to installing the software Should you have any questions during this installation upgrade process please feel free to contact us 1 800 653 5350 United States and Canada 55 11 4133 3180 South America 420 533 336 123 Europe the Middle East and Africa 1 800 457 439 Australia 65 6796 9600 select 2 for Technical Support Asia Pacific 001 631 738 6213 For international callers outside the US For additional support contact options visit http www motorola com Business US EN Support Support Contacts Motorola SiteScanner 13 1 Quick Start Guide Page 1 of 21 Table of Contents RECOMMENDED SYSTEM REQUIREMENTS 3 INSTALLATION ON WIN XP WIN VISTA OR WIN 7 rrr nnn nnne nnn annnm nune ua ua aa aua uua auus sU UU REN RR YN RR R RR RR Roa USUS Sr UR RR RA 3 PREPARATION DL 3 INST ALIA TION PROGEDURE LP IAS C cop cane ated 4 WLAN CARD HARDWARE REMOVAL PROCEDURE 4 CUST
15. caled drawing file Click Scale Drawing and follow the onscreen instructions You will be asked to select two points on the floor plan for which you know the distance and then enter the distance If you opened a formatted drawing file created in EnterprisePlanner or LANPlanner most likely it has already been scaled Check the box next to the This file has already been scaled option and then click Do Not Scale Motorola SiteScanner 13 1 Quick Start Guide Page 9 of 21 IMPORTANT NOTE You can still choose to scale the formatted drawing file in order to ensure that it is scaled properly Warning a Warning This File may not be to scale IF a drawing is not scaled properly the measurement visualizations may be inaccurate Would vau like bo scale Ehe drawing now This file has already been scaled Do Scale Step 4 You should now see your facility in the main drawing window You are now ready to perform a site survey Performing a Site Survey Step 1 Select the Measurement Survey menu gt Record New Data command to begin taking measurements Reports Utilities Help Configure Scan Settings Configure Authorized List Em Visualize Visualization Options TET 1 hall Import Measurement Data Export Measurement Data Delete Measurement Data Marker Settings Access Point Associations Step 2 In the Configure Real Time Measurement Run Information window there are several options a
16. eScanner 13 1 Quick Start Guide Page 11 of 21 Configure Real Time Measurement Run Information Measurement Run Information Measurement Run Name Default Final Floor4 1 Log File Location Files SiteScanner Workspaces Default Measured Default_Final_Floor4_1 milz Current Scan Settings amp uz 11b g n channels to scan 1 2 3 4 5 6 7 8 9 10 11 802 11 channels to scan 34 36 38 40 42 44 46 48 52 56 60 64 149 153 157 161 165 Total Scan Time 5 60 seconds Configure Scan Settings Next gt gt Step 5 If you need to change the default scan settings click the Configure Scan Settings button In the Configure Scan Settings window select the channels you wish to scan and make any desired changes to dwell times Click OK and then click Next on the Configure Real Time Measurement Run Information IMPORTANT NOTE We suggest that users select a dwell time of at least 150 ms for all channels scanned Configure Scan Settings IEEE 802 11 bfgin IEEE 802 11 Channel Width 20 MHz v Advanced Channel Dwell Time ms 11M Ext Channel Ch 1 2 412 GHz 00 None Ch 2 2 417 GHz 200 None Ch 3 2 422 GHz 200 None Ch 4 2 427 GHz 200 None Ch 5 2 432 GHz 200 None Ch 6 2 437 GHz 200 None Ch 7 2 442 GHz 200 None Ch 8 2 447 GHz 200 None Ch 9 2 452 GHz 200 None Ch 10 2 457 GHz 200 None Ch 11 2 462 GHz 200 None Ch 12 2 467 GHz 200 Ch 1
17. easily scale the attenuation of partition types based on the number of lines representing a wall in the drawing e Added the ability to edit the color of ceiling regions e Improved the workflow for changing the visibility of individual partition types e Improved the workflow for changing the visibility of equipment predictions measurements and other drawing data e Improved the workflow for changing the background image fade e Added the ability to change the visible thickness of partition types based on attenuation or type Equipment e APs can now be configured as dual mode AP Sensor devices e g the Tri Radio AP7131N e Full support for all device templates supported for management by ADSP e Sensors can now be moved across floors e The edit sensor dialog now displays the device model e The edit sensor dialog now displays the list of air standards supported by the device Measurements e The WLAN survey log file format has been updated Survey files now have the extension mlz e Improved the in survey scalability of WLAN surveys for large numbers of measurement locations e GPS enabled WLAN surveys are now supported Licensing e Improved workflow for product licensing e License server monitor is now a standalone application Motorola SiteScanner 13 1 Quick Start Guide Page 18 of 21 Critical Fixes e Fixed crash that occurred when the building wizard is opened while the measurement visualization panel
18. ect the have a License File option Use the Browse button next to the License File field to locate the file and select it Once you have selected the licensing file click Apply The license information is updated Using an Authorization Code If you have an authorization code select the have an Authorization Code option Enter your authorization code company name contact phone number and email address Then click Download The license is downloaded from the Connector and the license details are displayed at the bottom of the Connector License dialog Now click Apply The license is installed using the authorization code IMPORTANT NOTE If you need to use a proxy to access the internet select the Use proxy for Internet Access option The proxy settings must already be configured using Configure gt Configure Proxy Settings Multiple PC installation According to the license agreement your software can only be installed on one PC License unlock codes will not be provided for multiple PCs Motorola SiteScanner 13 1 Quick Start Guide Page 8 of 21 Introduction to Using SiteScanner Now that you have installed the software you can begin measuring and visualizing your WiFi network s performance This Quick Start Guide provides a brief tutorial on using the software to perform a site survey of your facility and then analyze your WiFi network through various visualization modes The following instructions provide a recommended wor
19. is active e Fixed a crash that occurred if the replace button is clicked when a sensor is selected within the BOM summary dialog e Fixed a bug where the application would hang when starting a SiteSpy server on Windows Vista e Fixed a bug where specific channel configurations involving 802 11a n channels 34 38 42 and 46 could not be scanned with the USB WLAN driver General Fixes Building Modeling e A default Floorl is now added to all drawings e The drawing legend is now automatically available in all drawings e Corrected meters feet conversions in the Prune Overlapping Partitions dialog e Fixed a bug where changing the set of drawing partition types to use the same types from the global partition library was not updating correctly Equipment e Equipment markers no longer removed during pre processing of the drawing for building formatting Measurements e Measurement data is now correctly scaled along with the result of the drawing within the existing scale drawing workflow e Cancel button no longer functions the same as the OK button in the Anritsu communication configuration dialog e Fixed a bug where the displayed legend for a throughput graphical marker view was incorrect in a certain workflow Miscellaneous e Measurement data no longer disappears from view when opening a drawing in SiteScanner e Fixed a bug where any device imported from log regardless of whether or not it was already ADSP was li
20. is ready to use the installation was successful and the card is now ready for use with RF Monitoring mode measurements Motorola RF Measurement Driver Installer Motorola Device Driver Installation Process Finished The drivers were successfully installed on this computer YoU can now connect pour device to this computer If your device came with instructians please read them first MOTOROLA Driver Mame Status Motorola 802 11 a b g n Ready to use If you encounter an error please contact Motorola s wireless software support team at Ems support motorolasolutions com License activation After installing the software you have 14 days to install the license Each time you access SiteScanner the Connector License dialog is displayed until the license is installed The Connector License dialog can also be accessed by selecting Help gt Manage Licenses Motorola SiteScanner 13 1 Quick Start Guide Page 7 of 21 Ctonnecter Leanne Seber MAL i criam Dini 931 havea Licence Pils O1 have an Authorgation Code nt aH Liner Type There are two methods used to install a license Using a license file Using an authorization code the most common method To use either of these methods to install a license you must have a license file or an authorization code from Motorola Using a License File A license file contains information about your license If you have a license file sel
21. kflow for doing site surveys and analysis using SiteScanner For additional information about how to use SiteScanner please refer to the online User Manual Help menu gt User Manual Requirements Before proceeding with the site survey you must first acquire a floor plan of the facility In order to import the floor plan into SiteScanner the floor plan needs to be in the following formats e Raster images BMP JPG TIFF formats e Raw facility CAD files DWG and DXF formats e Formatted facility drawing files files that were created in Motorola EnterprisePlanner LANPlanner or SiteScanner Loading Raster Images Raw CAD files or Formatted Drawing Files Step 1 Select the File menu gt Open Project Floor Plan command to access the Open Drawing dialog View Building Modeling Equipment Me Project Workspace New Drawing CTRL N Open Drawing CTRL C Save CTRL 5 Save 5 Management System Export Import d Exit Step 2 When the Open Drawing dialog opens browse to your floor plan s file and click Open You will be asked whether you wish to save changes for the current drawing file Click No Step 3 A Warning dialog will pop up asking you whether the file you have opened is scaled or not If you opened a raster image or a raw CAD drawing file you will need to scale the drawing file When performing a site survey it is extremely important to use a s
22. ng the following hardware removal process Failure to follow this process could cause your computer to crash and loss of data First close down or ensure that SiteScanner is not running Double click the Safe Hardware Removal icon in your system tray Select your Wireless LAN Adapter from the Safely Remove Hardware dialog and choose Stop Again select your adapter and select Ok to confirm you wish to remove the hardware Note this will not uninstall the driver This process simply allows you to safely unplug the adapter from your computer Step 5 You may now remove the WLAN Adapter from your computer Motorola SiteScanner 13 1 Quick Start Guide Page 4 of 21 Custom Driver Installation for the WLAN Client Card In order to enable data collection via RF Monitoring mode you will need one of the WLAN client cards listed in the recommended system requirements with SiteScanner s custom driver installed IMPORANT NOTE Do not install the card manufacturer s driver The installation of Motorola s custom WLAN driver may not work correctly if the manufacturer s driver has been previously installed on your computer If the manufacturer s driver or other suitable driver has been previously installed on your computer please uninstall the client card before proceeding Step 1 Insert the network adapter into your computer s PCMCIA slot or USB port Step 2 If the Hardware Update Wizard dialog window appears choose Cancel Hardwa
23. r clockwise in 90 degree increments Added support for rotating entities counter clockwise by an arbitrary angle Improved the workflow for changing the height of partitions Added the ability to lift partitions above the floor Improved the workflow for changing the material type of a partition Improved the workflow for aligning one floor with respect to the rest of the building Improved the workflow for drawing walls Improved the workflow for drawing rooms Added the ability to draw an arc based wall Improved the workflow for drawing ceiling regions Added the ability to free form erase partitions Added the ability to erase regions of partitions or ceiling within a polygonal boundary Added the ability to insert a doorway into existing partitions Added the ability to insert new partitions into existing partitions e g inserting a length of glass for a window into existing brick Improved the workflow for inserting a background image Added a modeless list of unformatted layers in the drawing for quick access to standard processing conversion features Improved workflow for changing the visibility of entire floors Improved workflow for adding deleting floors e Added the ability to create a copy of all building data on a floor e Improved workflow for changing the order of the building floor stack e Improved workflow for adjusting the free space path loss with respect to a suggested WLAN planning guide e Added the ability to
24. re Update Wizard Welcome to the Hardware Update eS Wizard Windows will search for current and updated software by looking on Your computer an the hardware installation CD or on the Windows Update Web site with your permission Windows connect to Windows Update to search for software Orres this time only T es now and every time connect a device No not this time Click Next to continue Step 3 Run the DriverSetup exe installer located in Help WLAN Drivers located within your installation directory Step 4 Click Next to begin the driver installation process Motorola RF Measurement Driver Installer Welcome to the Motorola Driver Installation Wizard This wizard will walk you through updating the driver used for taking measurements with Motorola s RF design tools Please insert a Wireless LAN card compatible with this driver package Far more details refer to the user manual MOTOROLA To continue click Next Motorola SiteScanner 13 1 Quick Start Guide Page 5 of 21 Step 5 You must accept the license agreement before installing the driver If you accept the agreement check the radio button accept this agreement and click Next Motorola RF Measurement Driver Installer Review the terms of the license agreement To continue accept the following license agreement To read the entire agreement use the scroll bar or press the Page Down key MOTOROLA INC END USER LICE
25. sted as a new device in the import in the drawing Motorola SiteScanner 13 1 Quick Start Guide Page 19 of 21 Known Issues Related to SiteScanner 13 x Compatibility with previous Motorola PC based software versions Note that earlier versions of SiteScanner cannot open drawings created with version 12 2 or higher When visualizing 802 11n performance for 40MHz channels it may be necessary to configure the color scheme for your visualization to include higher data rates than the default 130Mbps A suggested scheme has already been provided for this To assign the Peak Data Rate up to 300Mbps scheme 1 Open your drawing 2 Select Utilities gt Edit Color Schemes from the menu 3 Select the data rate display type you would like to change from the Color Scheme Assignment list Contour Data Rate Grid Data Rate etc 4 Click the Edit button in the Color Scheme Assignment section of the dialog 5 Select the Peak Data Rate up to 300Mbps color scheme Virtual Environments Not Supported SiteScanner currently is not supported on third party virtual environments such as Citrix or VMWare SiteScanner will only operate in a native operating system environment Some Unicode Characters will not display correctly when viewed in a 3D shaded mode Conflict with TrendMicro firewall TrendMicro firewall must be disabled before taking measurements in RF Monitoring mode with the Motorola SiteScanner 13 1 Quick Start Guide Page
26. t are not part of your network i e APs that are part of a neighboring office network APs classified as rogues are those APs that do not belong in the environment and should not be present Now click on the Configure Authorized List button In the Configure Authorized List dialog window you will see that all the MAC addresses for visible APs will initially be under the Rogue MAC Address section Select the authorized MAC addresses that are part of your network and click the lt lt lt Motorola SiteScanner 13 1 Quick Start Guide Page 13 21 button to populate them under the Authorized MAC Addresses Repeat this for the unauthorized addresses and then click OK Users can also load a text file list of authorized MAC addresses into SiteScanner The text file needs to have one MAC address per line with the following format for the address Configure Authorized List Manual Entry MAC Address 00 00 00 00 00 00 Add to the Authorized List or Add to the Roque List Input File Location Add to the Unauthorized List Rogue MAC Addresses MAC Address SSID Authorized MAC Addresses 00 40 8 6 60 00 A0 F8 BB FE 00 Unauthorized Addresses SSID 00 03 52 2C 5C A0 MAC Address 00 03 52 3 6 03 00 03 52 2C 8E DO 00 0 8 6 55 SYM DEV D00 0F 3D AD 38 AE 00 03 52 E2 80 40 00 18 SYM 00 14 A9 6A 9E 00 00 03 52 E2 80 4
27. tarting the installation process Log on as Administrator or as a user with administrative or power user privileges Insert the SiteScanner product CD into the CD drive or double click the Installation executable if downloaded from http support symbol com support product RFDesignandPlanning html If installing from a CD and Autorun is activated on your computer the setup program will start automatically Otherwise run SETUP EXE from the root folder on the product CD If installing from an installation executable choose a location for storing the temporary installation files These files can be removed at a later date or kept for product repairs or reinstallations Read the warnings and the license agreement You must accept the license agreement to continue To choose the destination folder where the program files will be stored on the hard drive click the Configure button next to the product selection We recommend you accept the default folder name If you choose a hard drive other than the default C drive be sure to also type in a directory name e g click on your D drive and then type in Program Files SiteScanner Click Next to begin the installation process When setup is complete you are ready to run the software by going to the Windows Start Menu and selecting Programs SiteScanner SiteScanner WLAN Card Hardware Removal Procedure IMPORTANT NOTE You should only remove your WLAN card adapter from your computer usi
28. vailable You can change the Measurement Run name the location where the measurement run log file is saved mobile receiver height and marker color Ensure that the WLAN Device option is selected from the Select Measurement Mode drop down menu before clicking Next Motorola SiteScanner 13 1 Quick Start Guide Page 10 of 21 Configure Real Time Measurement Run Information Measurement Run Information WORKSPACE C Program Files SiteS canner workspaces efaull Description Default Final floorl 1 Buding Notes 0 0 0 Create ASCII Lag File C Prograrn FilessSiteS Hecerver Height Above Floor Marker Color es Select Measurement Made WLAN Device hal Setup Instruction Neto Step 3 Select RF Monitoring in the Measurement Options window and click Next Measurement Options Select Client Made BF Monitoring Collect data fram all in range special adapter required Performance Connect to a single for ar network performance measurements GPS Enabled Select Server Mode 3 Server Create a server for Performance clients Step 4 In the Configure Real Time Measurement Run Information window there are several options available You can change the Measurement Run name the location where the measurement run log file is saved and what standards and channels to scan for Motorola Sit