Home
- Citygrow Energy Systems
Contents
1. CCP Two Gang Curtain Control Switch S00VA gang
2. 7 3 1 See ee ee re 10 7 3 2 Setting the open and close travel distant for the curtain 12 Adding the product to your Home Wireless ZigBee Network 14 SS Mi CAN Oe cent ace ic ee wr cee aires pe ste deseo adc TEA aes en ee ee eed xen eae 15 1 Introduction Thank you for buying Citygrow s product CG130 Series is both powerful and easy to use and install It is specially designed for wireless remote control Home Automation purpose Description L 10 11 12 13 14 ZigBee wireless remote control Based on IEEE 802 15 4 2 4GHz radio frequency CG130S1 S2 S4 DM DM2 is for lighting control CG130S2 CCP CG130S4 CCP is for control of electronic curtain or window blind LED indicator for on off status Load loads are directly driven by the build in driver Control button can be configured to become two way function Control button can be configured to become scene function Support iPhone iPad and Android mobile control if CG102BS Base station is purchased Control button graphics can be tailor made per customer requirement Mounted in a standard UK wall box No EIB Bus required Easy to install 2 Understanding of the product Button panel Control button Rear view Button panel Front view Programming port Metal clip to fix the button panel Control unit bottom view Load terminals KW N Contacts for button panel Live t
3. consult an electrician for replacement of the outlet Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus Only use attachments accessories specified by the manufacturer Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is used use caution when moving the cart apparatus combination to avoid injury from tip over Unplug this apparatus during lightning storms Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped Table of content L WIV OGU GG AA AA AA 1 Understanding of the product 2 IMME SIONS ANA 3 Wiring CG130S1 CG130S2 CG130S4 CG130DM CG130DM2 ccceeeeeeeees 3 Wiring CG130S2 CCP CG130S4 CCP uu aaa anna naanakan naaa ka anna nnka nka 5 iae esl le e g AA 6 Operation iINStruction a AN GAGANA 8 7 1 CG130S1 CG130S2 CG130S4 aan naa naaawa naaa knnaanaa nananana nanannann 8 7 2 CG130DM CG130DM2 aaaaaaaaaaaaaaaaaaaanana nanan nKNAKKKAKKKAR KKK AKKKA KAKANAN 9 7 3 CG13052 CCP CG13054 CCP nananana nna nna nna anna nana nnna naa nKna AA 10
4. CG130 SERIES ZIGBEE WIRELESS SWITCH USER MANUAL CG130S1 CG130S2 One Gang Switch Two Gang Switch CG130DM2 CG130S2 CCP Two Gang Dimmer One Gang Curtain Control Switch VERSION 0 0 157 APRIL 2015 CityGrow Systems Disclaimers and Copyright CG130S4 CG130DM Four Gang Switch One Gang Dimmer CG130S4 CCP Two Gang Curtain Control Switch Nothing contained in this publication is to be construed as granting any right by implication or otherwise for the manufacture sale or use in connection with any method apparatus or product covered by letters patent or as insuring anyone against liability for infringement of letters patent Efforts have been made to ensure the accuracy and reliability of the data contained in this publication however Citygrow Energy Systems Limited makes no representation warranty or guarantee in connection with this publication and hereby expressly disclaims any liability or responsibility for loss or damage resulting from its use or from the use of any product or methodology described herein for any violation of any federal state or municipal regulation with which this publication may conflict or for the infringement of any patent from the use of this publication Nothing contained in this publication should be viewed as an endorsement by Citygrow Energy Systems Limited of any particular manufacturer s products CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION T
5. Loosen the screws of the original wall switch Remove the switch and disassemble the wiring STEP 3 Connect the main power cable to the Live and Neutral terminals and the load cable to the Load terminals at the rear cabinet of the product STEP 4 Fasten the screws of all terminals and check that the wires are properly secured Retrofit the switch into the standard switch box and mount it on the wall by fastening the two screws at the rear of the switch box CG130 l Screw x 2 pcs power unit Wall box Make sure the button panel is locked into the power CG130 button panel unit STEP 5 Push the ON OFF button to test whether the wiring has been connected correctly If the ON OFF Button does not function as expected please check the wiring connection again Notes Use standard UK wall box BS4662 minimum 35mm deep During installation of the wall box it is recommended to embed the wall box deeper inside the wall in order to give more room to install the product The room inside is recommended to have 50mm deep 7 Operation instruction 7 1 CG130S1 CG130S2 CG130S4 CONTROL PANEL LED Indicator ON OFF Button Program port Metal clip Mounting hole Press ON OFF Button once to toggle between ON and OFF BRIGHT LED indicates that the Switch is ON DIMMED LED indicates that the Switch is OFF 7 2 CG130DM CG130DM2 CONTROL PANEL Dim Up LED Indicator Dim Down LED Indicator Pr
6. O REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER OR BACK NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL user to the presence of uninsulated dangerous voltage within the product s enclosure that may The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the bi be of sufficient magnitude to constitute a risk of electric shock to persons The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the product Oa IMPORTANT SAFETY INSTRUCTIONS READ BEFORE OPERATING EQUIPMENT This product was designed and manufactured to meet strict quality and safety standards There are however some installation and operation precautions which you should be particularly aware of ee eS NOE 10 11 12 13 14 Read these instructions Keep these instructions Heed all warnings Follow all instructions Do not use this apparatus near water Clean only with dry cloth Do not block any ventilation openings Install in accordance with the manufacturer s instructions Do not install near any heat sources such as radiators heat registers stoves or other apparatus that produce heat Do not defeat the safety purpose of the polarized or grounding type plug If the provided plug does not fit into your outlet
7. eading Control Curtain Edge Edge Switch Control Dimming Dimming Switch Operating voltage AC220 240V 50Hz Maximum number of 50 50 50 50 50 NO NO devices included in scene setting Remarks 1 2 Remarks When up button is used for dimming up function the down button cannot be programmed as scene function Maximum number of devices programmed into the whole product is limited to 50 devices The maximum load requirements for fluorescent CFL and LED loads can vary greatly depending upon the specific fixture and or bulb being used When dimming transformer is connected to CG130 make sure dimmable and leading edge type is used Furthermore the dimming performance varies greatly from manufacturer to manufacturer of the bulb and the dimming transformer It is recommended to test the matching performance before mass deployment Minimum dimming level NO NG NG YES YES NO NO setting RF frequency 2 4GHZ 2 4GHZ 2 4GHZ 2 4GHZ 2 4GHZ 2 AGHZ 2 4GHZ Remote control distance 100M 100M 100M 100M 100M 100M 100M M line of sight Dimensions mm Length x G x6 x35 Ofxe x59 6 x67 x395 O x6 x39 ofxG x39 B x01x39 O x6 x39 Width x Depth Recommended operation 0 to 40 O to 40 O to 40 degt O to 40 0 to 40 temperature degC degC eg de degC degC 15 Description Resistive load 1 Incandescent 2 Halogen 3 Electronic low voltage ELV transformer Inductive load 1 Magnetic low voltage MLV transformer 2 ron core Inductive
8. erminal Brown NC Motor 1 Motor 1 NC NC Backward Forward Motor 2 Motor 2 Motor 1 Motor 1 Backward Forward Backward Forward 3 Dimensions CG130S2 85mm lt l 38 5MM 4 Wiring CG130S1 CG130S2 CG130S4 CG130DM CG130DM2 Notes The Neutral wire of load is closely connected to the Neutral point of CG130 Situation 1 Live Neutral and Load wires are ready at wall box Wall box Distribution panel Situation 2 Live and Load wires are ready at wall box Neutral wire is only ready at ceiling Neutral Wall box Distribution panel Before getting started WARNING It must be installed by a qualified electrician in accordance with all applicable regulations and building codes Improper wiring can result in personal injury or damage to control units or other equipment Always turn off circuit breaker or remove main fuse from power line before doing any work To avoid overheating and possible damage to equipment WARNING Do not operate when any lamps removed or burned out replace any burned out lamps immediately use only transformers that incorporate thermal protection or fused primary windings This product is designed for residential and commercial use for indoor use only WARNING Install in accordance with all national and local electrical codes IMPORTANT Citygrow is not liable for any damage incurred with the misuse of this product IMPORTANT Pre setup can only be done by a
9. ogram port Metal clip Mounting hole POWER MODULE Press the Dim Up Dim Down button ONCE to Toggle between ON and OFF LED FLASHING indicates that that the Button was pressed and dimming is in progress When the LED stops flashing it indicates that the dimming is complete Press and HOLD the Dim Up Dim Down button to begin dimming Release the button at desired level 7 3 CG130S2 CCP CG130S4 CCP 7 3 1 Operation CONTROL PANEL HUG Open button Close button OPEN CLOSE Program port Metal clip Mounting hole POWER MODULE 10 Press the Open Close Button once to control the electric curtain When the electric curtain is stopped press the OPEN button to open the electric curtain When the electric curtain is stopped press the CLOSE button to close the electric curtain When the electric curtain is running press ANY button to stop the electric curtain 11 7 3 2 Setting the open and close travel distant for the curtain The function of the Learning Mode in the CG130S2 CCP is to program the duration of the curtain Opening Closing time In order to perform the Learning Mode function please follow the below steps STEP 1 Press the CLOSE Button until the curtain is fully closed NOTE You may have to press the Button once or more times in order for the curtain to be fully closed STEP 2 Ka Press and HOLD the Reset Button While still holding the Reset Butt
10. on press and HOLD the Open Button STEP 3 CLOSE Release the Reset Button Wait until the LED Indicators begins BLINKING Release the Open Button NOTE The curtain should be opening at this point STEP 4 CLOSE Once the curtain is fully opened press and release any Button NOTE The duration of the Opening Closing time will be stored once the Button is pressed STEP 5 CLOSE Use a thin object to press the Reset Button again The learning process of the CG130S2 CCP has now finished Do the same for CG130S4 CCP the only difference is CG130S4 CCP will control 2 curtains CG130S2 CCP can only control 1 curtain So for CG130S4 CCP will need to program both curtain travelling time 13 8 Adding the product to your Home Wireless ZigBee Network 14 STEP 1 Open the front cover you will see a 5 pin connector STEP 2 Plug the CG101UT5 cable into the 5 pin connector of the product and then plug the other end of the CG101UT5 cable into the mini USB end of the CG101UTC cable STEP 3 Plug the CG101UTC cable into the USB port of a PC that is installed with Citygrow s HomeNET Planner Software STEP 4 Refer to the user manual of HomeNET Planner Software to program and set the address of the product 75 Systems 9 Specification Description One Gang Two Gang Four One Gang Two Gang One Gang Twa Switch Switch Gang Dimmer Dimmer Curtain Gang Switch Leading L
11. professional worker or manufacturer agent 5 Wiring CG130S2 CCP CG130S4 CCP Neutral au SS Wall box Live penal B Curtain motor AC 4 Pf en O OKAAN Wall O OWAWAA NAKAKA Co Distribution panel A Conduit Wall box NM AAA AN Before getting started CG130S2 CCP WARNING It must be installed by a qualified electrician in accordance with all applicable regulations and building codes Improper wiring can result in personal injury or damage to control units or other equipment Always turn off circuit breaker or remove main fuse from power line before doing any work To avoid overheating and possible damage to equipment WARNING Do not operate when any lamps removed or burned out replace any burned out lamps immediately use only transformers that incorporate thermal protection or fused primary windings This product is designed for residential and commercial use for indoor use only WARNING Install in accordance with all national and local electrical codes IMPORTANT Citygrow is not liable for any damage incurred with the misuse of this product IMPORTANT Pre setup can only be done by a professional worker or manufacturer agent 6 Installation In order to install the product correctly please follow the below steps STEP 1 IMPORTANT Turn off main power at the main switch board ONJO NJO NIO Nf JO NIO NO ONJON SBAS B88 EE OFFIPFFIDFFDFF IPFADFADFA OFFIOFA STEP 2
12. transformer Fluorescent CG613051 One Gang Switch 20004 2000VA 1400W Compact fluorescent CFL LED GU10 LED MR16 MR11 With electronic low voltage LED driver LED strip With electronic low voltage driver Exhaust fan 3 wire type AC curtain motor Minimum load TECHNICAL INFORMATION AND PICTURES SUBJECTED TO CHANGE WITROLT PRIOR NOTICE 200W 400W Max 24 pcs ELV LED driver Max 10 pcs ELY LED driver CG13052 Two Gang Switch 1000W gang 10D0VA gang TOOW gang ADOW gang Max 24 pcs CFL Gang 200W gang ADOW gang Max 24 pcs ELV LED driver Gang 400VV gang Max 10 pcs ELV LED driver S00VA CG13054 Four sang Switch 500W gang 500VA gang 350W gang 200W gang Max 12 pcs CFUGang 100W gang 200W gang Max 12 pcs ELV LED driver Gang 200W gang Max 5 pcs ELV LED driver Gang 200VA gang CGO130DM One Gang Dimmer Leading Edge Dimming om 4DOW Dimmable CFL Max 20 pcs CFL 120 CG130DM2 CO13052 CCP One Gang Curtain Control Switch Two Gang Dimmer Leading Edge Dimming 300V gang S00VA gang 200 gang Dimmable CFL Max 20 pcs CFL Gang S0W gang 60W gang Max 15 pcs ELV LED driver Gang Copyright 2012 Ctiygrow Energy Systems Ltd All Rights Reserved 16 Systems C615054
Download Pdf Manuals
Related Search
Related Contents
Model 311 and 611 Laboratory Incubators Manual Pioneer AVIC X3 Operation Manual ficha tecnica montblanc Extensor Powerline Inalámbrico N AV200 de 300Mbps 801L to 302L Line Interactive UPS V1-0 OH Assist Customer Portal Multiquip MVC88VTH User's Manual Manual Español-Portuguese ツインパワー給湯器の強みです Texto completo Copyright © All rights reserved.