1. Step 5 After changing the IP address click the Apply button in the USB Configuration window Step 6 A message pops up asking you to affirm the action as OK Step 7 Click OK and remove the USB connection from your PC Step 8 Click Exit at the bottom of the USB Configuration window to close the window Or choose the Launch button to see the local camera images directly Step 9 Before clicking Launch check your PC s IP address and use the Network connector RJ 45 to link up with your camera Step 10 If you can see the images it means the IP setting is complete 5 Scan IP Camera through My Network Place Step 1 After your installation and starting services the UPnP protocol will take effect You can scan all IP Cameras in My Network Place Step 2 Just double click the IP Camera icon and the video live stream will pop up automatically without assigning any IP address in Microsoft Internet Explorer 6 Change the IP Camera s control and operational settings Step 1 Type in the IP address in the IE Browser You will now see the IP camera images Step 2 Use the buttons below the images to enter any other operational settings pages Step 3 When you change any setting please don t forget to click the Submit button in each page NOTE Enable DHCP Function This function can only work if the LAN which the unit is connected to has a DHCP server If the DHCP server is working the IP Camera wil
2. T 9 The 2 0 Megapixel Fixed IP Outdoor Mini Dome PoE he Component Parts the internal view GF _ RIRN Plug Inlet A DC 12V inlet that connects to an external power supply Plug Inlet An AC 24V inlet that connects to an external power supply ETHERNET 10 100 Connector This is a standard RJ 45 connector for 10 100 Mbps Ethernet networks PoE Power over Ethernet function Provides power to the device via the same cable as used for the network connection AUDIO IN The connector is used to connect the audio output from other devices to the camera VIDEO OUT Connector The connector provides the units composite video signals to a monitor This connector adjusts and improves the images AUDIO OUT Provides the camera s audio signal to a speaker or stereo GPIO This is a 6 PIN connector including the Digital output input DC output and GROUND items for connecting with external devices USB port The user can use a USB device cable to connect the IP camera to the USB port on the PC SD SDHC CARD slot This is used for updating system software and archiving accessing critical images 10 RESET Recover to factory default he Alarm Wiring Diagram 12V Digital output Digital output Digital input Digital input DC output GND 12V Reed switch RMN0100550 Please follow the steps given below to install configure and set
3. ed RMNO100550 V1 2
4. l obtain an IP address automatically from the DHCP server NOTE When only one unit of the IP Camera is connected to a computer or LAN you can freely assign an IP address for the IP Camera For example there is a range of IP Camera IP addresses from 192 168 1 1 to 192 168 1 255 You can pick one for use from the range of the IP It s not necessary to set MASK and GATEWAY leave the settings as default When an IP Camera is connected to a WAN you must acquire a unique permanent IP address and correctly configure the MASK and GATEWAY settings according to your network architecture If you have any questions regarding those settings please consult a qualified MIS professional or your ISP RMN0100550 The Installation of the Fixed IP Outdoor Step 3 Detach the top iron base from the dome Step 5 Attach the flank panel cover on top of the Mini Dome PoE camera Put the flat metal strip atop the port Screw the cover in over the flat Attaching the dome via the flank dome and screw it in with the two screws metal strip Step 1 Fix the iron base to the ceiling with the nails Attach the iron base atop the dome and and the nylon nails screw it in place t gp J pA t25mm L _ SELF TAPPING SCREWS NOTE Wrong Step 2 Unscrew the flank panel cover and take it off Right M3 5 L _ SCREW Step 4 Insert the cable in the flank port Attach the flank panel cover on
5. nstallation by UL and marked at 24Vac 60 Hz minimum 1A class 2 or LPS The interconnecting cables should be placed inside 1 Plug in the power connection to the IP camera 2 Plugin the IP camera cable the UL certified Outdoor Use Conduits 3 Confirm the correct network connection status CAUTION PC HUB IP camera RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE DISPOSE OF USED BATTERIES 4 Inthe PC IE Browser key in the camera s IP ACCORDING TO THE INSTRUCTIONS online to link up to the live first page 4 RMNO100550 Specifications 1 2 7 Omni Vision 2M CMOS sensor Lens 3 3 12mm Vari focal board type VGA type 3 9mm Vari focal board type MEGA type TE T VGA type Color 0 3 Lux F1 4 B W 0 03 Lux F1 4 Mout en eran anon MEGA type Color 0 2 Lux F1 2 B W 0 01 Lux F1 2 Auto Day Night Schedule 4 3 1440x1080 1280x960 1024x768 800x600 640x480 480x360 320x240 and 160x120 16 9 1920x1080 1280x720 800x450 640x360 480x270 320x180 and 176x120 Simultaneous H 264 MPEG4 and MJPEG Multi profile resolution compression frame rate video quality Single profile 1920x1080 27FPS Multprotie 1920x1080 20FPS Adjustable image size quality and bit rate Day Night mode Flip amp Mirror Image settings AGC AWB AES Time stamp and text caption overlay P
6. rivacy masks Exposure Mode Video management software SDK including HTTP API ActiveX ONVIF Two way Compression ss G 711 G 726 Fonpesson bit rate G 711 64kbps G 726 32kbps Camera Resolution Video streaming Video streaming Inputs outputs lt 1 x input 1 x output 3 5mm earphone jack Multi level password protections IP address filtering HTTPS encryption User access log IPv4 HTTPS HTTP TCP UDP RTP RTCP RTSP DHCP NTP FTP NEIwOrk SMTP UPnP ICMP ARP DDNS PPPoE SAMBA Access by 10 simultaneous users SD card HTTP Pre alarm recording recording Yes 512 zones Sensitivity 0 100 Motion Detection Schedule Trigger Alarm input Ethernet loss Network Remote digital alarm input vei Push in 2 x digital input 2 x digital output gang 11 x DC output 12V DC 1 x ground Earphonejack_ 2 x3 5 mm 1x Audio in mic in line in 1 x Audio out line output Reset for factory default 12V DC DC power jack Approx 4 8W 24V AC 2 pin terminal block Approx 6W 802 3af compliant Power over Ethernet C IEEE 802 3af Class 2 er es Di ions Package Werhe n ea 123 x 150 mm Hx W 2 25 kg Quick Installation Guide CD x 1 includes User s Manual Power adapter Input 100 240 VAC 50 60 Hz Output 12VDC 1A RJ 45 cable x 1 Specifications are subject to change without notice Security Connectors Accessories includ
7. tallation will be done and choose Finish to close it 3 Turn on Services of your PC After installation we should turn on the relative services to start the UPnP protocol The following procedures will teach you how to do it Step 1 From the Start menu point to Settings and then click Control Panel Step 2 When Control Panel appears double click the Administrative Tools icon The Administrative Tools dialog box appears Step 3 Click the Services icon in the Administrative Tools dialog box Step 4 When the Services dialog box shows up double click the SSDP Discovery Service icon Step 5 Choose Automatic in the Startup type and click OK to start it Step 6 When the Services dialog box appears again double click the Universal Plug and Play Device Host icon Step 7 Choose Automatic in the Startup type press the Start button and click OK to start it Step 8 Restart your system 4 Set the static IP address in the IP Camera Step 1 Plug in its power connection Step 2 Plug the USB connector in your PC and in the USB socket in the rear of the lens Step 3 A window pops up asking if you want to Run the program Open folder to view files or Take no action Choose Run the program and click OK and the USB configuration window will pop up Step 4 Set the Network setting and type in the IP address you desire Before you change the IP address you should note the factory default Static IP address 192 168 1 168
8. the IP Camera 1 Check the IP class of your PC Step 1 From the Start menu point to Settings and then click Control Panel Step 2 When Control Panel appears double click the Network Connections icon The Network Connections dialog box appears Step 3 Click the Protocols tab in the Network Connections dialog box Step 4 When the Local Area Connection Properties dialog box shows up choose Internet Protocol TCP IP and click Properties Step 5 In the Internet Protocol TCP IP Properties dialog box choose Use the following IP Address to indicate that you do not wish to use DHCP and assign IP Address 192 168 1 200 with Subnet mask 255 255 255 0 Click OK when you finish it Step 6 Choose Close to finish the modification 2 Install UPnP Packets of your PC As described before Microsoft Windows XP doesn t start the UPnP service by default however we have to install some packets before we initialize it The following steps will help you to install them Step 1 From the Start menu point to Set Program Access and Default and then click it Step 2 When the Add or Remove Programs dialog box appears click the Add Remove Windows Components button Step 3 Check the Network Services in the Windows Component Wizard dialog box and then click Details Step 4 Check UPnP User Interface and choose OK Step 5 When the original Network Component Wizard dialog box returns click Next Step 6 After about one minute the UPnP ins
9. top of the port Screw the cover in over the flat metal strip i t Step 6 The dome is now attached to the ceiling NOTE The dome camera is available from us The other component parts are also available but optional for the buyer 3 RMNO100550 NOTE The user can replace the desiccant pack depending on how often the camera interior has been opened to the environment Stick and fix a desiccant pack to the inner side of the camera with a two side adhesive tape then reattach WARNING the cover of the camera To prevent fire or shock hazard avoid exposing this unit to rain or moisture Do not block ventilation openings Do not place anything on top of the unit that might spill or fall into it Do not attempt to service this unit yourself as opening or removing covers may expose you to dangerous voltage or other hazards Please refer all servicing to your distributor retailer Do not use liquid cleaners or aerosols for cleaning To prevent fire or electric shock do not overload wall outlets or extension cords PoE warning If the PoE injector is used instead of the supplied power adaptor all of the wiring to and from the injector must be routed installed inside a building plant and never routed installed outside of the building plant Please only select a power adapter or power certified Hardware I