Home

IS5300 User Manual

image

Contents

1. _ y All management modules in the chassis must go through an initial configuration proce dure See the Installation Guide for the initial configuration procedure ba 5 6 Switch Shut Down Procedures 5 6 1 To shut down the chassis run the following command twice Reload halt noconfirm The switch cannot be restarted remotely To restart the switch you must physically go to the switch and unplug and replug gt in all of the power cords to the chassis The first time you run the command it shuts down the master management module and the second time shuts down the slave management module 5 6 2 To shut down a leaf run the following command Reload halt noconfirm 5 6 3 To shut down a spine run the following command Reload halt noconfirm 68 Mellanox Technologies 324 Port InfiniBand QDR Switch Platform Hardware User Manual Rev 1 8 6 Disassembly and Disposal 6 1 Disassembling the Chassis Power down the chassis Remove all power cables Remove all connector cables Disconnect the ground lug from the ground post Remove all leafs Remove all spines AN ne Remove all management modules Use enough people to safely lift this product AR lt 40 lbs 40 70 lbs 70 121 lbs gt 121 lbs lt 18 kgs 18 32 kgs 32 55 kgs gt 55 kgs This product and all of its parts are NOT to be disposed of with household waste This gt d product contains printed circuit boards cables and b
2. TECHNOLOGIES d ET T a CID 000000000 E ESD connecto Ground Post Mellanox Technologies 53 Rev 1 8 Installation 3 6 Power Connections The switch includes integrated hot swap power supplies which support up to 6 load sharing 1000W supply units The slots for the power supply units PSUs are on the spine side The left side has odd numbered PSUs and the right side has even numbered PSUs Each PSU has a dedi cated AC inlet This design enables the optional use of separate main and backup AC feeds The input voltage is Autorange 100 240 VAC 50Hz or 60Hz The output voltage for the PSUs is 48V The power cords should be standard 3 wire AC power cords including a safety ground Before starting any procedure on the 185300 series switch system put an ESD prevention wrist strap on your wrist and connect to the 185300 series Chassis 3 6 1 Powering Up the Switch Platform Note Make sure that the power cords are compatible with your outlets Power cords for differ ent countries can be ordered from Mellanox 1 Plug in the power cords to the PSUs 2 Plug the other end of the power cord into a grounded outlets Make sure that the outlets and circuits will not be overloaded Spread out the load over at least two or three circuits or use a 3 phase circuit The chassis must be started with a full compliment of PSUs thereafter it can run on one less than the total number of PSUs This final PSU is redundant and allows for h
3. 324 Port InfiniBand QDR Switch Platform Hardware User Manual Rev 1 8 4 Chassis Power Up Before starting any procedure on the 185300 series chassis system put an ESD prevention wrist strap on your wrist and connect to the 185300 series chassis The chassis must be started with a full complement of PSUs that is6 Thereafter it can run on one less than the total number of PSUs This final PSU is redundant and allows for hot swapping a PSU should one fail Connecting the PSUs to different AC lines provides AC failover protection A system should continue to run and allow a hotswap of a defective PSU Should there not be enough power to keep all of the leafs running FabricIT EFM may power down some leafs If this happens it may be necessary to reboot the chassis once the defective PSU has been replaced 1 Check all Boards Power supplies Leaf fan modules Spine fan modules for proper insertion and seating before connecting the AC power cords Insert all leafs that you plan to use in the chassis Insert thermal blanks in unused leaf slots to maintain balanced air flow Tighten all mounting screws Connect the power cords to the PSUs Nu P wD Connect the power cords to grounded electrical outlets Do not power up the chassis with less than all PSUs installed Populate the chassis with the leafs before you power up the chassis 4 1 Power Supply and Spine Board Indicator Status at Power ON It can take up to 5
4. 15 without condensing Y It is highly recommended that the installation sites be as isolated as possible from all sources of radio transmissions and electrical interference 30 Mellanox Technologies 324 Port InfiniBand QDR Switch Platform Hardware User Manual Rev 1 8 It is highly recommended that the installation site building be equipped with a light ning rod It is highly recommended that the installation site be equipped with smoke detectors and a fire alarm warning system The system requires a KVA rated UPS system The heat dissipation is calculated Power Dissipation x 3 42 Heat Dissipation It is recommended that a UPS system be installed to protect the equipment in the event of unexpected power failure Make sure that the outlets and circuits will not be overloaded Spread out the load over at least two or three circuits or use a 3 phase circuit 3 2 Chassis Package Contents The package includes e 1 chassis with the following modules installed 9 spines management module 4fans 6PSUs e 1 installation kit e 1 box containing 6 power cords 250v 15a 2 0M C14 to C13 USA UL Standard e 1 cable management kit Before you install your new 185300 series chassis unpack the system and check to make sure that all the parts have been sent check this against the parts list Check the parts for visible damages that may have occurred during shipping The leafs are shipped separately A second redund
5. 324 Port InfiniBand QDR Switch Platform Hardware User Manual Rev 1 8 8 TroubleShooting As each PSU is plugged in make sure that the green power LEDs on the PSU come on 8 1 Power Supply Unit 99 Vf the Power supplies cannot supply enough power the management module may shut down the system If the AC power LED is off Check that the power cable is the correct power cable for your country Check that the power cable is plugged into a working outlet Check that the power cable has a voltage within the range of 100 240 volts AC Remove and reinstall the power cable Check the circuit breakers to be sure that the breaker has not tripped Check that the power cable is good Replace the power cable If the AC power LED is green but the OK power LED is off or the FAIL LED is on Replace the PSU Sa QUE p Dre 8 2 Leaf Board The power LED for the Leaf board is off 1 Make sure that all of the PSUs are showing DC OK 2 Uninstall and reinstall in the Leaf board 3 When the Yellow LED is on this indicates a fault in the board uninstall and reinstall the Leaf board 4 If uninstalling and reinstalling the Leaf board does not work burn the latest FW on the Leaf board and uninstall and reinstall the Leaf board 5 Replace the Leaf board with a new one 99 Should any of the boards shut down due to over temperature wait 5 minutes and then fol low the procedure starting with Step 2 gt The Physic
6. 8 Mellanox Technologies 324 Port InfiniBand QDR Switch Platform Hardware User Manual Rev 1 8 About this Manual This manual provides an overview of the IS5300 modular InfiniBand chassis switch and guide lines for its operation Intended Audience This manual is intended for users and system administrators responsible for installing and setting up the chassis platform The manual assumes familiarity with the InfiniBand architecture specification Related Documentation The documentation set accompanying the QSFP Chassis InfiniBand Switch platform includes the following Table 2 Reference Documents and Web Sites FabricIT Enterprise Fabric Management Software See CLI User s Manual http www mellanox com gt Products gt Management Software Select FabricIT EFM InfiniBand Fabric Management Click Software and Documentation Download center select User Manual Switch Hardware Installation Guide Each Mellanox Technologies switch platform is shipped with an Installation Guide document that contains instructions for Instal lation in a rack and initialization of the switch platform IB Switch Platforms Embedded Management Tools Describes the Embedded Management Tools EMGT package Document no 2141UM which provides Out of Band management capabilities for InfiniBand switches Available from http docs mellanox com requires a Mellanox Technologies customer account Switch Firmware and Firmware Update
7. of leaf blanks 0 764 3 15 if you will have two management modules 1 15 if you will have only one management module weight of the chassis plus the leaf boards spines PSUs and Management modules installed in the chassis 82 Mellanox Technologies 324 Port InfiniBand QDR Switch Platform Hardware User Manual Rev 1 8 Appendix C Calculating the Power of a Customized Chas sis To calculate the power consumption of a customized chassis take the base power and add the power of the fans spines management modules and leafs Table 14 Power Consumption of Chassis Parts Part typ power passive cables SR hover ne eye IB QDR leaf 82 28W 121 45 Spine 103W Not applicable Fan 45 Not applicable Management Module 20 Not applicable To calculate the chassis power 103W of spines 20W of management modules 45W of fans 82 28W of leafs for passive cables or 121 45W of leafs for active cables 0 85 Where 0 85 is the power supply efficiency Mellanox Technologies 83 Rev 1 8 Appendix D QSFP Interface 0___ en eno Y Table 15 InfiniBand QSFP Connector Pinout 21 non Rxin 18 _ 22 Rx2p Rxip 17 _ Connector Connecto 23 GND anp 16 Pin r Pin Signal Description 24 15 Number Name Rx4n Rx3n IT 25 Rxdp Rx3p 14 1 GND Grou
8. 1 4 Spine Side Panel Display LED Indicators 24 2 1 5 Management Module LED Indicators 26 2 1 6 Port Connector Interfaces 26 2 2 AirFlow 27 2 3 QSFP Cable Power Budget Classification 27 2 4 Management Module Interfaces 27 2 4 1 RC 28 2 42 CONSOLE 28 2 4 3 MGT Management 28 244 USB 28 2 4 5 Reset RST 28 Chapter 3 Installation 30 3 1 Environmental and Safety Recommendations 30 3 2 Chassis Package Contents 31 3 3 Leaf Package Contents 32 3 4 Management Package Contents 32 3 5 Physical Installation 32 3 5 1 Starting with the Rack 33 3 5 2 ESD Connection 34 3 5 3 Installation Procedure 34 3 5 4 Installing the Cable Holder 52 3 5 5 Ground Connections 53 3 6 PowerConnections 54 3 6 1 Powering Up the Switch Platform 54 3 7 InfiniBand QSFP Cable Installation 55 3 7 1 Cable Power Classes 56 Chapter 4 Chassis Power Up 57 4 1 Power Supply and Spine Board Indicator Status at Power ON 37 Chapter 5 Insertion and or Hotswap Extraction 59 Mellanox Technologies 3 Rev 1 8 5 1 Power Supply Units 59 5 1 1 Extracting and Inserting the Power Supply Unit 59 5 2 LeafBoards 61 5 2 1 Extracting a Leaf Board 61 5 2 2 Inserting a Leaf Board 62 5 3 Spine Boards 62 5 3 1 Extracting a Spine Board 62 5 3 2 Inserting a Spine Board 63 5 4 Fan Modules 64 5 4 1 Leaf Fan Module 64 5 4 2 Spine Fan Modules 65 5 5 Management Module 66 5 5 1 Extracting a Management Module 66 5 5 2 Inserting a Management Module 67 5 6 Sw
9. 18 32 kgs 32 55 kgs gt 55 kgs 3 Installation in Restricted Access Location YN This unit is intended for installation in Restricted Access Location 4 Over temperature ing the maximum recommended 45 C 113 F Moreover to guarantee proper air This equipment should not be operated in an area with an ambient temperature exceed A flow allow at least 8cm 3 inches of clearance around the ventilation openings 5 Stacking the Chassis The chassis should not be stacked on any other equipment If the chassis falls it can cause bodily injury and equipment damage 6 Redundant Power Supply Connection Electrical Hazard power supply do not operate the product with the blank cover removed or not securely This product includes a redundant power or a blank in its place In case of a blank A fastened 16 Mellanox Technologies 324 Port InfiniBand QDR Switch Platform Hardware User Manual Rev 1 8 7 During Lightning Electrical Hazard During periods of lightning activity do not work on the equipment or connect or dis connect cables 8 Copper InfiniBand Cable Connecting Disconnecting attached to or detached from the connectors Refer to the cable manufacturer for spe Copper InfiniBand cables are heavy and not flexible as such they should be carefully A cial warnings instructions 9 Rack Mounting and Servicing When this product is mounted or serviced in a rack special precautions must be taken LA to ensure t
10. 460EX Rev at 1000 MHz PLB 200 OPB 100 EBC 100 MHz Security Kasumi support Bootstrap Option H Boot ROM Location I2C Addr 0x52 Internal PCI arbiter disabled 32 kB I Cache 32 kB D Cache Board Mellanox PPC460EX Board FDEF No I2C ready DRAM 2 GB ECC enabled 400 MHz CL3 FLASH 16 MB NAND 1024 MiB PCI Bus Dev VenId DevId Class Int PCIEO link is not up PCIEl successfully set as root complex 01 00 15b3 bd34 0c06 00 Net ppc_4xx eth0 ppc_4xx ethl Hit Ctrl B to stop autoboot 0 Mellanox FabricIT Boot Menu 1 EFM PPC M460EX EFM 1 1 1000 2010 06 24 16 32 03 ppc 2 EFM PPC M460EX EFM 1 1 1200 2010 06 25 18 00 03 ppc 3 U Boot prompt Choice 5 Select the image to boot 78 Mellanox Technologies 324 Port InfiniBand QDR Switch Platform Hardware User Manual Rev 1 8 Appendix A Specification Data A 1 Specifications Table 13 Switch Specification Sheet IS5300 Physical Power and Environmental HxWxD Weight Mounting Max Air Flow Through leafs Max Air Flow Through spines SerDes Speeds Connector Types Center of Gravity CoGh CoGw CoGd Max Heat Output 28 x 19 x 27 inches 711 mm x 482 6mm x 685 mm The shelf adds 44 5mm to the height 212 36 kg full configuration 468 lbs full configuration 90 kg 199 Ibs empty configuration 19 Rack mount EIA 310 16 59M3 min 585 9 CFM 9 48 M3 min 334 8 CFM 20 and 40 Gb s per port
11. Off Link is down Solid Green Logical connection Flashing Green Data activity Orange Physical connection 2 1 3 2 Fan LED The Spine Fan indicator LED has the following led assignment Table 9 Spine Fan Status LED LED Description Green Spine Fan is OK Yellow One or more of the fans in this spine is not working Each spine has two fans in the fan module 2 1 3 3 Spine to Leaf IB Connection Status LEDs These LEDs indicate a valid connection between a leaf and a spine The Spine to Leaf IB Connection Status LEDs have the following led assignment Table 10 Spine to Leaf IB Connection Status LEDs LED Description Green A valid connection exists between this spine and the num bered leaf Yellow A valid connection does not exist between this spine and the numbered leaf 2 1 4 Spine Side Panel Display LED Indicators The spine side panel display has LEDs that show the chassis condition 24 Mellanox Technologies 324 Port InfiniBand QDR Switch Platform Hardware User Manual Rev 1 8 Figure 9 Spine Side Panel Display Status Indications CS A O O STATUS PSU SPINE LEAF MGT 1 MGT 2 STATUS FANS FANS STATUS STATUS Table 11 LEDs Display for Normal Operation de Normal LED Description State STATUS Off No Power Green Green System is up and running Yellow System warning Attention needed such as overheating Red System not operational
12. QSFP 311 8 mm from bottom of chassis 222 mm from left side surface 328 14 mm from port end surface Measured from the bottom left corner as one faces the switch ports 12 305 BTUs hr Input Voltage Temperature Humidity Power Consump tion Leaf Power Consump tion Spine Power Consump tion for Active cables QSFP 185300 Power Consump tion 90 264 VAC 50 60Hz 13A 100V 6 3A 240V 10 to 45 Celsius 10 90 non condensing Typical 82 28W not including QSFP power Max 89 74W not including QSFP power Typical 102 86W include 2 Fans Max110 32W include 2 Fans 2 0W Power level 2 324 ports Typical 3919 80W including QSFP at 2W Typical 3595 80W including QSFP at 1W Max 4509 72W including QSFP at 2W Mellanox Technologies 79 Rev 1 8 Table 13 Switch Specification Sheet IS5300 Protocol Support Regulatory Compliance InfiniBand QoS Management Auto Negotiation of 20Gb s 40Gb s 8 InfiniBand Virtual Lanes for all ports Baseboard Performance and Device management Agents for full InfiniBand In Band Management Safety EMC ENVIRONMEN TAL ACCOUSTIC SOUND POWER LEVEL US Canada cTUVus EU IEC60950 International CB USA FCC Class A Canada ICES Class A EU EN55022 Class A EU EN55024 Class A EU EN61000 3 2 Class A EU EN61000 3 3 Class A Japan VCCI Class A EU IEC 60068 2 64 Ran
13. Technologies 5 Rev 1 8 Figure 35 Offset to Upper bracket Bolts 50 Figure 36 Lock Down Bar 50 Figure 37 Bolt and Washer Order 51 Figure 38 Cable Holder 52 Figure 39 Ground Connection 53 Figure 40 Multiple Power Inlets Electric Caution Notification 55 Figure 41 Spine Module 55 Figure 42 Top and Bottom Ports 56 Figure 43 Spine Side Panel Display Status Indications 58 Figure 44 Management Module Status Indications for Normal Operation 58 Figure 45 Power Cord Top Bar 60 Figure 46 Power Supply 60 Figure 47 Ejector Latch 61 Figure 48 Leaf Release 62 Figure 49 Ejector Latch 63 Figure 50 Spine Board Extraction 63 Figure 51 Fan Locations on the Chassis 64 Figure 52 Leaf Fan Module Extraction 65 Figure 53 Spine Fan Module 65 Figure 54 Fan Status LED on the Spine Module 66 Figure 55 Ejector Latch 67 Figure 56 Management Module 67 Figure 57 Mechanical Lifting Device 70 Figure 58 QSFP Connector Male and Female Views 85 6 Mellanox Technologies 324 Port InfiniBand QDR Switch Platform Hardware User Manual Rev 1 8 Table of Lists Table 1 Revision History of this User s Manual 8 Table 2 Reference Documents and Web Sites 9 Table 3 Switch Rack Mechanical and Environmental Requirements Fully Populated Chassis 13 Table 4 Leaf Status LED 21 Table 5 Bad Port LED Configurations 22 Table 6 Connector Physical and Logical Link Indications 22 Table 7 Spine Status LED 23 Table 8 Spine to Leaf IB Link Status 24 T
14. Verbindung von wesentlicher Bedeutung werden 15 Add GND Verbindung Informationen Add GND connection information Bevor Sie dieses Ger t an das Stromnetz die Schutzerde Terminal Schrauben dieses Ger t muss an den Schutzleiter in der Geb udeinstallation 16 INSTALLATION CODES INSTALLATION CODES Dieses Ger t muss installiert sein entsprechend auf die neueste Version des Landes National Electrical Code F r Nordamerika m ssen in Ubereinstimmung mit den gel LA tenden Vorschriften in der US amerikanischen National Electrical Code und dem Canadian Electrical Code 17 Zusammenschaltung von EINHEITEN INTERCONNECTION OF UNITS Kabel f r den Anschluss an das Ger t RS232 und Ethernet Schnittstellen m ssen UL zertifiziert Typ DP 1 oder DP 2 Hinweis wenn nicht mit Wohnsitz in LPS Schal LA tung berstromschutz Eine leicht zug ngliche Auflistung Abzweigleitung berstrom Schutzeinrichtung 20 A bewertet werden m ssen in dem Geb ude Verkabelung Mellanox Technologies 93 Rev 1 8 Appendix H Advertencias de seguridad para la insta laci n Spanish 1 Instrucciones de instalaci n Antes de conectar el equipo a la fuente de alimentaci n leer todas las instruc ciones de instalaci n 2 Lesi n corporal por peso Dado que el equipo es muy pesado se debe mover nicamente mediante un elevador mec nico para evitar lesiones gt 3 Instalaci n en un lugar con acceso restringido Esta unidad ha sido
15. before inserting the new part This is necessary so that the management module will start a new cycle checking through the leafs and spines for the FW ver sions gt There are four fan modules on the chassis for the leafs They are located on both sides of the chas sis two on the leaf side corners and two on the spine side When a fan module is not functioning the status LED on the fan will light up There are two different fan modules for the chassis These fans have different model numbers and are not interchangeable The fans on the leaf side of the chassis are MTF005001 whereas the fans on the spine side of the chassis are MTF005002 gt Figure 51 Fan Locations on the Chassis Fans Fi Fa e el e e e I L Ea H A T e D 1 1 ei AC5 e e 1 1 1 nT 5 4 1 Leaf Fan Module There are four Leaf fan modules Two leaf fan modules are found on the Leaf side and two leaf fan modules are found on the Spine side The leaf side fans are not interchangeable with the spine side fans Air flow through the leafs is independent of the air flow through the spines 5 4 1 1 Extracting the Leaf Fan Module 1 Push and hold the blue latch release See Figure 52 2 Slowly pull out the fan module using the handle 64 Mellanox Technologies 324 Port InfiniBand QDR Switch Platform Hardware User Manual Rev 1 8 Figure 52 Leaf Fan Module Extraction Handle Latch 5 4 1 2 Inserti
16. homologu s UL Pour les prises lectriques en Am rique du Nord choisissez un cordon lectrique homologu UL et certifi CSA 3 conducteurs 18 AWG termin par une fiche moul e d une tension nominale de 125 V 15 A avec une longueur minimale de 1 5 m 6 pieds et d une longueur maxi male de 4 5 m 18 pieds Pour les prises lectriques en Europe choisissez un cordon lectrique harmonis inter nationalement et marqu lt HAR gt gt 3 conducteurs d un diam tre de fil minimum de 0 75 mm2 d une tension nominale de 300 V avec une gaine isol e en PVC Le cordon doit avoir une fiche moul e d une tension nominale de 250 V et d une intensit nominale de 10 A 90 Mellanox Technologies 324 Port InfiniBand QDR Switch Platform Hardware User Manual Rev 1 8 Anhang G Installation Sicherheitshinweise German 1 Installationsanleitungen Lesen Sie alle Installationsanleitungen bevor Sie das Ger t an die Stromversorgung anschlieBen 2 Ubertemperatur Dieses Ger t sollte nicht in einem Bereich mit einer Umgebungstemperatur ber der maximal empfohlenen Temperatur von 45 C 113 F betrieben werden Es ist ein Luft LA strom von 200 LFM bei maximaler Umgebungstemperatur erforderlich AuBerdem sollten mindestens 8 cm 3 in Freiraum um die Bel ftungs ffnungen sein um einen einwandfreien Luftstrom zu gew hrleisten 3 Stapeln des Chassis Das Chassis sollte nicht auf andere Ger te g
17. instalar o realizar el mantenimiento de este aparato en un bastidor es preciso adoptar precauciones especiales para garantizar que el sistema se mantenga estable En general en un bastidor los equipos se deben instalar comenzando desde abajo hacia arriba 10 Instalaci n de equipos La instalaci n el reemplazo y el mantenimiento de este equipo estar n a cargo nicamente de personal capacitado y competente 11 Asegurar confinamientos adecuados El fabricante del producto final o el usuario final deber n suministrar un confinamiento adecuado para componentes el ctricos y mec nicos y contra incen dio 12 Eliminaci n de equipos La eliminaci n definitiva de este equipo se debe efectuar conforme a todas las leyes y reglamentaciones nacionales 13 C digos el ctricos locales y nacionales Este equipo se debe instalar conforme a los c digos el ctricos locales y nacionales gt Mellanox Technologies 95 Rev 1 8 14 Cable de alimentaci n homologado por UL y con certificacion CSA AR En conexiones de America del Norte seleccionar un cable de alimentaci n homologado por UL y con certificaci n CSA de tres conductores 16 AWG termi nado en un enchufe moldeado con capuch n de 125 voltios nominal 13 A con una longitud minima de 1 5 metros pero no m s de 4 5 metros En conexiones europeas seleccionar un cable de alimentaci n armonizado internacionalmente y marcado lt HAR gt de tres
18. is below the Mellanox logo on the spine side of the chassis FabricIT CM license is located on the bottom side of the pull out tab Mellanox Technologies 11 Rev 1 8 Overview Figure 1 Generic Product Label N MT0949X001 5300Q Made in IL This is the System Image GUID according to the IB spec It is burned on the board which is in the chassis All the boards and the management SW look for this GUID in addition to their own Node GUID Figure 2 Product Label Tab Location Top right hand side of the spine side of the chassis Tab location with Product label and management MAC 155300 i i HE Ba 1 1 2 Management Module MAC Each management module has a label with its MAC address See below for the location of this label Figure 3 Management Module MAC Address Location CONSOLE MGT RE RST PSU S FANS LFANS MASTER I l MGT MAC 00 02 C9 11 34 8A Ti Ph EM EOS VU NN AL MAC address location 12 Mellanox Technologies Product Physical Specifications and Power 324 Port InfiniBand QDR Switch Platform Hardware User Manual Rev 1 8 Table 3 Switch Rack Mechanical and Environmental Requirements Fully Populated Chassis Rack of leafs Up to 6 Power Supplies of 100 240VAC 50 60Hz 6 3 13A Height Rack Width Rack Weight Max Power 648 x QSFP Ports Ambient Depth a Temp Required of Spines 17U 19 EIA 25 7 18 9 212 36 kg 468 lbs full Typi
19. module gt switch 1 Orca648 master config no power enable S06 2 Push outward on the latches to unlock the ejectors from the chassis 3 Open the ejectors until they are 90 degrees from the module 4 Pull out on the module using both ejectors 62 Mellanox Technologies 324 Port InfiniBand QDR Switch Platform Hardware User Manual Rev 1 8 Figure 49 Ejector Latch Pull the module out of the chassis Management Module Spine Management Module Spine _ Push the latch gt release p E Figure 50 Spine Board Extraction Pull the latches to remove the spine 19 21 2325 27 29 31 33 35 ooog gogogo 20 22 2426 28 30 32 34 36 5 3 2 Inserting a Spine Board 1 Start with the latches fully open that is perpendicular to the front panel of the leaf Hold the spine board by the sides with both latches fully open Insert the board into its rail The board should slide in without resistance Push the board in until the hooks on the latches are touching the vertical bar ES Now press both latches inward simultaneously You should feel the latches are hooked into the front panel 6 Press both latches applying some force to close them completely The locking latch will engage Mellanox Technologies 63 Rev 1 8 Insertion and or Hotswap Extraction 5 4 Fan Modules When hotswapping any of the units it is necessary to wait 1 minute after removing the defective part
20. protective earth terminal screws of this device must be connected to the protective earth in the building installation LA GND Connection Information The building installation shall provide a means for connection to protective earth and the equipment shall to be connected to that means permanently by a service person A SERVICE PERSON shall check whether or not the socket outlet from which the equipment is to be powered provides a connection to the building protective earth If not the SERVICE PERSON shall arrange for the installation of a PROTECTIVE EARTHING CONDUCTOR from the separate protective earthing terminal to the pro tective earth wire in the building The equipment shall be installed in area where equi potential bonding exists such as a telecommunication centre or a dedicated computer room 16 Installation codes This device must be installed according to the latest version of the country national electrical codes For North America equipment must be installed in accordance to the applicable requirements in the US National Electrical Code and the Canadian Electri cal Code 17 Interconnection of units Cables for connecting to the unit RS232 and Ethernet Interfaces must be UL certified type DP 1 or DP 2 Note when residing in non LPS circuit YN Overcurrent Protection A readily accessible Listed branch circuit overcurrent protec tive device rated 20 A must be incorporated in the building wiring 18 Hazardous Ra
21. rack sup port 16 Make sure the upper brackets are installed in their correct location 17 Screw the bolts through the faceplate into the caged nuts and tighten all 8 bolts and nuts 18 For each offset and upper bracket screw six bolts through the offset into the upper bracket Use one flat washer and one lock washer for each of these bolts Mellanox Technologies 49 Rev 1 8 Installation Figure 35 Offset to Upper bracket Bolts 19 Place the front lock down bar at the edge of the chassis and align the holes in the lock down bar with the holes in the shelf Screw down the lock down bar You will need the 10 hex head screws and washers for each lock down bar Figure 36 Lock Down Bar These holes are to screw the bar into the Chassis These holes are to screw the bar into the shelf 20 Screw down the second lock down bar 50 Mellanox Technologies 324 Port InfiniBand QDR Switch Platform Hardware User Manual Rev 1 8 Figure 37 Bolt and Washer Order n N P U H U H gt S L A 2 21 Remove the shelf extension and save for removal of the chassis i Y 3 22 Connect a valid ground See Section 3 5 5 Ground Connections on page 53 for detailed instructions 23 Go to Section 4 Chassis Power Up on page 57 to power up the switch system Mellanox Technologies 51 Rev 1 8 Installation 3 5 4 Installing the Cable Holder Now is the time to install the cab
22. spine side of the shelf 7 Install and tighten the 12 M6 bolts into the caged nuts Figure 23 Shelf Brackets N N N N N N N er N The spine side of M N the shelf has two N yl slots for the N i N extension gt N ST N N N N N N N N N AN Adjustable she brackets Mellanox Technologies 41 Rev 1 8 Installation 8 Tighten the 16 hex head bolts on the adjustable brackets 9 Connect the lock down bar onto the shelf at the connector side See Figure 24 to identify the spine side of the shelf Figure 24 Place the Lock Down Bar on the Shelf A u the lock down bar here The spine side of the shelf has two slots for the exten sion 10 Place 8 caged nuts into the vertical rack support at the locations corresponding to the holes in the chassis faceplate The holes in the faceplate start at 2U above the shelf and are spaced every 4U centered as you go up the vertical rack support There are 4 holes on each side 42 Mellanox Technologies 324 Port InfiniBand QDR Switch Platform Hardware User Manual Rev 1 8 Figure 25 U Numbering Above Shelf The first cage nut on the spine side goes here The next six caged nuts go every 4 U units up from here 3 5 3 4 Inserting the Chassis 1 Put the container on the fork lift Mel
23. the ejectors from the chassis 4 Open the ejectors until they are 90 degrees from the module 5 Pull out on the module using both ejectors Figure 55 Ejector Latch Pull the module out of the chassis Management Module Spine Management Module Spine Push the latch release Note The board is short therefore do not let go of it while sliding it out Figure 56 Management Module MGT SRS RST PSU SFANS LFANS MASTER CTS li nil Ejectors 5 5 2 Inserting a Management Module 1 Start with the latch fully open that is perpendicular to the front panel of the leaf 2 Carefully seat the management module into the slot and slowly slide the board into the chassis until the ejectors begin to engage on the chassis edge Mellanox Technologies 67 Rev 1 8 Insertion and or Hotswap Extraction 3 Press the ejectors inward until the locks snap This indicates that the board is fully seated On switch systems with dual management systems first connect the cable and configure the master management module CPU and only then configure the slave By default the gt master CPU is the top management module For further information on the master and af slave roles see the FabricIT EFM Software UM section High Availability for more information Initial configuration must be done on all of the management modules See the Installa tion Guide for the Initial Configuration procedure
24. the lock down bars and 12 for the upper brackets to upper bracket offsets 2 upper brackets 1 open end ratchet wrench 10mm 1 socket wrench 2 extensions for the socket driver 2 flat washers for the shelf extension The installation will be much easier with a power screwdriver It is recommended to use AWG6 or 4mm diameter wire for grounding purposes It is recommended to have at least two people for the duration of the installation proce dure Use a mechanical lift to raise this chassis If not use enough manpower to ensure the safety and wellbeing of all of the people involved in the installation 1 shelf extension 1 right side upper bracket offset 2 upper bracket washers 12 lock washers for the upper brackets to upper bracket offsets 34 caged nuts 12 for the shelf and 8 for the chassis faceplate 20 flat washers 8 for the lock down bars and 12 for the upper brackets 32 hex head bolts 20 for the lock down bars and 12 for the upper brackets to upper bracket offsets 12 flat head screws with locktite for the upper bracket offsets 1 socket nut driver 8mm 1 socket nut driver 10mm 1 socket nut driver 13mm e Parts included in the cable management installation kit Mellanox Technologies 35 1 cable management rack RH 10 caged nuts M6 1 cable management rack LH 10 M6 bolts Rev 1 8 Installation Figure 16 Installation Kit Parts Shelf Lock down bar Shelf extension Upper bracket Upper bracket
25. there is nothing blocking the front or rear of the chassis and that the fan mod ules and ventilation holes are not blocked especially dust over the holes If you find dust blocking the holes it is recommended to clean the fan unit and remove the dust from the front and rear panels of the switch using a vacuum cleaner Determine which fan module is problematic by checking the status LED on each fan module Remove and reinstall the problematic fan unit Make sure the mating connector of the new unit is free of any dirt and or obstacles See Section 5 4 on page 64 Replace the Leaf fan module There are two non interchangeable types of leaf fan modules If the new leaf fan does not go into the chassis confirm that it is the correct fan module YN Replace defective leaf fan modules as soon as they are identified 324 Port InfiniBand QDR Switch Platform Hardware User Manual Rev 1 8 Should any of the boards shut down due to over temperature follow the procedure start ing in Step 1 8 3 3 Yellow LED for the Spine Fan on the Management Module is Lit Determine which spine has a defective fan by checking the Fan LEDs on all of the spines 2 Make sure that there is nothing blocking the front or rear of the chassis and that the fan mod ules and ventilation holes are not blocked especially dust over the holes 3 If you find dust blocking the holes it is recommended to clean the fan unit and remove the dust from the front and rear p
26. 601 Cables Set For IS5600 SX6536 Series MTRO05602 IS5600 SX6536 IS5300 SX6518 Series Modular MTF005001 Switch leaf cooling chassis fan unit located on Leaf Side IS5600 SX6536 IS5300 SX6518 Modular Switch MTFO05002 leaf cooling chassis fan unit located on Spine Side 155600 5X6336 IS5300 SX6518 Modular Switch MTF005005 Series Spine Fan Unit Fan unit for spines MTF005003 DB9 to RJ45 Harness HAR000028 Power cord 250V 15A 2 0M C14 to C13 ACC000334 Power cord 125V 15A 2 0M C14 TO C13 ACC000242 Power cord Type B for USA Canada Mexico Taiwan ACC000204 Power cord Type H for Israel ACC000205 86 Mellanox Technologies 324 Port InfiniBand QDR Switch Platform Hardware User Manual Rev 1 8 Part Description OPN Power cord Type E F for Sweden France Germany ACC000207 Netherlands Russia Power cord Type G for UK ACC000208 Power cord Type D for India ACC000209 Power cord Type I for China ACC000210 Power cord Type J for Switzerland ACC000211 Power cord Type B for Japan ACC000212 Power cord Type I for Australia ACC000213 Mellanox Technologies 87 Rev 1 8 Appendix F Avertissements de s curit d installation French 1 Instructions d installation Lisez toutes les instructions d installation avant de brancher le mat riel la source d alimentation lectrique 2 Temp rature excessive Ce mat riel ne doit pas fonctionner dans une
27. AMA Mellanox TECHNOLOGIES 324 Port InfiniBand QDR Switch Platform Hardware User Manual PN MIS5300 Rev 1 8 www mellanox com Rev 1 8 NOTE THIS HARDWARE SOFTWARE OR TEST SUITE PRODUCT PRODUCT S AND ITS RELATED DOCU MENTATION ARE PROVIDED BY MELLANOX TECHNOLOGIES AS IS WITH ALL FAULTS OF ANY KIND AND SOLELY FOR THE PURPOSE OF AIDING THE CUSTOMER IN TESTING APPLICATIONS THAT USE THE PRODUCTS IN DESIGNATED SOLUTIONS THE CUSTOMER S MANUFACTURING TEST ENVIRON MENT HAS NOT MET THE STANDARDS SET BY MELLANOX TECHNOLOGIES TO FULLY QUALIFY THE PRODUCTO S AND OR THE SYSTEM USING IT THEREFORE MELLANOX TECHNOLOGIES CANNOT AND DOES NOT GUARANTEE OR WARRANT THAT THE PRODUCTS WILL OPERATE WITH THE HIGHEST QUALITY ANY EXPRESS OR IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGE MENT ARE DISCLAIMED IN NO EVENT SHALL MELLANOX BE LIABLE TO CUSTOMER OR ANY THIRD PARTIES FOR ANY DIRECT INDIRECT SPECIAL EXEMPLARY OR CONSEQUENTIAL DAMAGES OF ANY KIND INCLUDING BUT NOT LIMITED TO PAYMENT FOR PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES LOSS OF USE DATA OR PROFITS OR BUSINESS INTERRUPTION HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY WHETHER IN CONTRACT STRICT LIABILITY OR TORT INCLUDING NEGLIGENCE OR OTHERWISE ARISING IN ANY WAY FROM THE USE OF THE PROD UCT S AND RELATED DOCUMENTATION EVEN IF ADVISED OF THE POSSIBILITY
28. Diagnostics fail CPU hang HW fail Overheat critical Blinking Yellow System booting Restore factory defaults in progress PSU STATUS Off No power Green Green Normal operational Red PS fault detected User should check individual power supplies for fault indications SPINE FANS Off No power to fan Green STATUS Green Nominal operational Yellow Non fatal failure Red Fatal failure Turn the chassis off and then troubleshoot LEAF FANS Off No power to fan Green STATUS Green Nominal operational Yellow Non fatal failure Red Fatal failure Turn the chassis off and then troubleshoot MGT 1 STATUS Off no power or this management module is not installed Green Green Management module is operating as a master Yellow Management module is operating as a slave i e the other man agement module is a master MGT 2 STATUS Off no power or this management module is not installed Yellow Green Management module is operating as a master Yellow Management module is operating as a slave i e the other man agement module is a master Mellanox Technologies 25 Rev 1 8 Hardware 2 1 5 Management Module LED Indicators Figure 10 Management Module Status Indications tatus The management module LEDs display the switch system operating conditions Table 12 LEDs Display for Normal Operation He Normal LED Description State STATUS Off No Power Green This LED shows Green Syste
29. OF SUCH DAMAGE Mellanox TECHNOLOGIES Mellanox Technologies Mellanox Technologies Ltd 350 Oakmead Parkway Suite 100 PO Box 586 Hermon Building Sunnyvale CA 94085 Yokneam 20692 U S A Israel www mellanox com Tel 972 4 909 7200 Tel 408 970 3400 Fax 972 4 959 3245 Fax 408 970 3403 O Copyright 2011 Mellanox Technologies All rights reserved Mellanox BridgeX ConnectX CORE Direct InfiniBlast InfiniBridge InfiniHost InfiniRISC InfiniScale InfiniPCIO PhyX Virtual Protocol Interconnect and Voltaire are registered trademarks of Mellanox Technologies Ltd FabricIT MLNX OS and SwitchX are trademarks of Mellanox Technologies Ltd All other marks and names mentioned herein may be trademarks of their respective companies QDR InfiniBand Switch Platform Hardware User Manual 2 Mellanox Technologies Document Number 3240 324 Port InfiniBand QDR Switch Platform Hardware User Manual Rev 1 8 Table of Contents Table of Contents 3 Table of Figures 5 Table of Lists 7 Revision History 8 About this Manual 9 Intended Audience 9 Related Documentation 9 Conventions 9 Chapter 1 Overview 11 1 1 Product Information 11 1 1 1 Serial Number and Product Version Information 11 1 1 2 Management Module MAC 12 1 2 Features List 15 Chapter 2 Hardware 16 2 1 LED Status Indicators 20 2 1 1 Power Supply Unit LEDs 20 2 1 2 Leaf Board LED Indicators 21 2 1 3 Spine Board LED Indicators 23 2
30. Tools See http www mellanox com content pages php pg management_tools amp menu_section 34 Note that the Switch System described in this manual is based on Mellanox Technologies InfiniScale IV switch device Unified Fabric Manager UFM The user manual can be downloaded together with the software package upon license purchase Conventions Throughout this manual the name IS5300 and the term switch are used to describe the 324 port QSFP InfiniBand chassis unless explicitly indicated otherwise Mellanox Technologies 9 Rev 1 8 The following pictures are used throughout this document to indicate information that is important to the user 10 Mellanox Technologies 324 Port InfiniBand QDR Switch Platform Hardware User Manual Rev 1 8 1 Overview This User Manual provides an overview of the 185300 QSFP Modular InfiniBand Switch Platform known in this document as the switch and its operational environment Mellanox 185300 switch system provides the highest performing fabric solution by delivering high bandwidth and low latency to Enterprise Data Centers EDC High Performance Computing HPC and Embedded environments Networks built with the IS5300 system can carry converged traffic with the combination of assured bandwidth and granular quality of service Built with Mel lanox s 4 generation InfiniScale IV InfiniBand switch device 155300 systems provide up to 40Gb s full bidirection
31. able 9 Spine Fan Status LED 24 Table 10 Spine to Leaf IB Connection Status LEDs 24 Table 11 LEDs Display for Normal Operation 25 Table 12 LEDs Display for Normal Operation 26 Table 13 Switch Specification Sheet IS5300 79 Table 14 Power Consumption of Chassis Parts 83 Table 15 InfiniBand QSFP Connector Pinout 84 Table 16 Replacement Parts Ordering Numbers 86 Mellanox Technologies 7 Rev 1 8 Revision History Table 1 Revision History of this User s Manual Revision Date Details 1 8 July 2011 Changes to Reset button section Changes to installtion kit parts and procedure Changed name to Hardware User Manual 1 7 May 2011 Removed InfiniBand Fabric Initialization and Management Updated Fabric Management Software Section 1 6 Jan 2011 Added lock washer and flat washer positions for the lock down bar bolts 1 5 Nov 2010 Added New KCC statement 1 4 Oct 2010 Added air flow direction 1 3 Oct 2010 Added procedure step to screw in 9 screws through the offset into the upper bracket Fixed Port Connector LED Assignment 1 2 July 2010 Added QSFP Cable Power Budget Classification Added weight lifting warning Added Remove all protective plastic film from all sides and top of the chas sis Added FCC Statement 15 19 Added CoG and Max Heat to the Specs in Appendix A 1 1 July 2010 Fixed chassis height on page 10 1 0 July 2010 Initial release
32. al bandwidth per port With up to 324 ports in a 17U high form factor these systems are among the densest switching systems available The switch platform comes pre installed with all necessary firmware for standard operation within an InfiniBand fabric and requires an InfiniBand compliant Subnet Manager running from one of the hosts or the management module of the switch system An initial configuration procedure should be followed to initialize the switch before connecting it to the network after which normal operation can proceed See the installation guide for details regarding the initial configuration Once connected to the network the Subnet Management software automatically discovers and configures the fabric and begins utilizing the switch It is recommended that the Mellanox OpenFabrics software package be installed on all nodes con nected to the switch The software package provides a subnet manager and network management tools as well as connectivity software for servers and storage and is available on the Mellanox web site Basic installation is covered in Chapter 3 Installation on page 30 Hot swapping components and hardware maintenance is covered in Chapter 5 Insertion and or Hotswap Extraction on page 59 1 1 Product Information 1 1 1 Serial Number and Product Version Information The serial number GUID Identifier and product version information are found on the label that is attached to the pull out tab that
33. al link LED for the InfiniBand connector does not come on 1 Check that both ends of the cable are connected 2 Check that the locks on the ends are secured 3 Make sure that the latest FW version is installed on both the HCA card and the switch Mellanox Technologies 75 Rev 1 8 TroubleShooting 4 5 If media adapters are used check that the all connections are good tight and secure Replace the cable The Activity indication does not come on Check that the Subnet Manager has been started 8 3 Management Module 8 3 1 Yellow Status LED for the Chassis on the Management Module is Lit 1 Sie En Reset the master management module by pushing the rest button If you havev two manage ment modules installed this will convert the master management module to the slave and con vert the slave to the master Make sure the S Fans and L Fans LEDs are green Make sure that the spine and the leafs both have the same version of FW Reburn the FW and remove and reinstall the management module If you are running the chassis with only one management module remove and reinstall the management module Make sure the mating connectors of the unit are free of any dirt and or obstacles See Section 5 5 on page 66 If you are running the chassis with only one management module replace the management module 8 3 2 Yellow LED for the Leaf Fan on the Management Module is Lit 1 76 Mellanox Technologies Make sure that
34. all move out of the way The chassis can The chassis is on ball bearings and can roll easily Be aware that the chassis can roll off A cause grave bodily harm should it fall on or near you 1 Select the location in the rack Try to keep the chassis as low as possible to keep the center of gravity low It is recommended to set the shelf at US Try and keep the chassis as low as possible The maximum height that the chassis can be mounted will be determined by the maximum height that the fork lift can raise the pallet 2 Open the Installation kit and make sure that all of the parts are in the box See Figure 16 Installation Kit Parts The chassis will sit in the rack with the spine side as close as possible to the door The distance between the vertical supports must be between 65 and 80 cm If the dis tance in your rack is different move the vertical supports so that one pair is 10 cm din away from the door 4 The side of the chassis with the spine units will sit flush with the vertical supports of the rack The side of the chassis with the QSFP connectors will sit at the edge of the shelf closer to the center of the rack N 3 Measure the distance between the vertical supports and adjust the shelf bracket according to this distance This chassis can be installed a rack with a distance between the vertical supports of from 65cm 25 6in to 80cm 31 5in 38 Mellanox Technologies 324 Port InfiniBand QDR Switch Pl
35. anels of the switch using a vacuum cleaner 4 Remove and reinstall the fan unit of the spine Make sure the mating connector of the new unit is free of any dirt and or obstacles See Section 5 4 on page 64 5 Replace the spine fan module LA Replace defective spine fan modules as soon as they are identified 8 4 Spine Board The yellow LED on the Spine board is lit 1 Make sure that there is nothing blocking the front or rear of the chassis and that the fan mod ules and ventilation holes are not blocked especially dust over the holes 2 If you find dust blocking the holes it is recommended to clean the fan unit and remove the dust from the front and rear panels of the switch using a vacuum cleaner 3 Remove and reinstall the spine board Make sure the mating connectors of the unit is free of any dirt and or obstacles See Section 5 3 on page 62 Make sure that the spine and the Leafs both have the same version of FW 5 Reburn the FW and remove and reinstall the spine Replace the spine board 8 5 FabricIT SW The last software update did not succeed 1 Connect the RS232 connector CONSOLE to a laptop 2 Push the reset button on the switch or management module 3 You will have 5 seconds to stop the U Boot by pressing Control B 4 Choose the image to upload Only use image 1 or image 2 Mellanox Technologies 77 Rev 1 8 TroubleShooting U Boot 2009 01 mlnx1 4 May 12 2010 14 08 15 CPU AMCC PowerPC
36. ansfer will be reduced and the bit error rate will increase gt All cables can be inserted or removed with the unit powered on To insert a cable press the con nector onto the port receptacle until the connector is firmly seated The orange LED indicator above the port will light when the physical connection is established when both ends of the cable are properly connected to working devices Allow 15 seconds for link to get up To remove dis engage the lock and slowly pull the connector away from the port receptacle For a valid physical connection both ends of the cable must be connected to working devices A Take care to not impede the air flow through the ventilation holes next to the InfiniBand ports Use cable lengths which allow routing horizontally around to the side of the chassis before bending upward or downward in the rack Cables in the bottom row should be inserted up side down in relation to the how the cables are inserted in the top row Figure 42 Top and Bottom Ports al E 3 7 1 Cable Power Classes Chassis and switches need to be able to dissipate the heat generated by high power I O cables and modules The Mellanox IS5X00 series chassis are rated for cables up to class 2 as per the SFF committee classification SFF 8436 PDF See http www mellanox com content pages php pg cables for the cable class rating of Mellanox cables 56 Mellanox Technologies
37. ant management module when ordered is shipped separately A Mellanox Technologies 31 Rev 1 8 Installation 3 3 3 4 3 5 If anything is damaged or missing contact your customer representative immediately 4 The rack mounting holes conform to the IEA 310 standard for 19 inch racks Guaran tee proper ventilation by leaving 8cm 3 of space to the front and rear of the switch This will ensure proper air flow through the chassis This is crucial for maintaining good airflow at ambient temperature In particular route cables such that they do not impede the air into or out of the chassis 4 Leaf Package Contents The leafs are ordered by the customer and are shipped 4 to a box The customer will receive as many boxes as needed to fill the order Management Package Contents The package includes e one management module ordered by the customer e 1 RJ45 to DB9 harness Physical Installation chassis weighs 468 lbs 212 kg Make sure that proper manpower and equipment Warning This equipment is very heavy Safety is the first concern The fully loaded A is used for transporting and moving the chassis The switch platform uses 17U of rack space in a standard 19 rack 16U for the chassis and 1U for the shelf The switch ships from the factory with mounting holes on the spine side There are upper brackets to connect the leaf side to the rack near the top of the chassis and there are two lock down bars to secure t
38. atform Hardware User Manual Rev 1 8 Figure 18 Vertical Rack Supports Dimension 4 The shelf comes with the four brackets pre installed Two of the brackets should be loose They may need to be removed and repositioned to meet the distance between the vertical sup ports of the rack Figure 19 Adjustable Shelf Brackets These two brackets will need to be adjusted They may even need to be removed and repositioned The holes in the bracket are offset to one side The holes must be closer to the top of the shelf Mellanox Technologies 39 Rev 1 8 Installation Figure 20 Top of Shelf Bracket The holes in the bracket are offset to one side The holes must be closer to the top of the shelf op of shelf Bottom of shelf is even with this side of the bracket the greater distance between the holes and the edge of the bracket show that this is the bottom side Figure 21 Placing the Shelf Bracket Adjusting slots 5 Insert three caged nuts into the rack for each of the four shelf brackets Make sure that the caged nuts are all at the same height on the vertical supports 40 Mellanox Technologies 324 Port InfiniBand QDR Switch Platform Hardware User Manual Rev 1 8 Figure 22 Caged Nut Locations for the Shelf Brackets 6 Put the Shelf into the rack and twist the shelf into place Make sure the spine side of the shelf is closest to the rack doors See Figure 24 to identify the
39. atteries According to the WEEE Directive 2002 96 EC all waste electrical and electronic equipment EEE should be be collected separately and disposed of according to the directive 8 Dispose of these pieces in a legal and environmentally friendly way 6 1 1 Removing the Chassis Remove the screws connecting the upper brackets to the rack 2 Remove the screws holding the chassis to the rack These screws are located in the faceplate on the spine side of the chassis 3 Remove the upper brackets from the chassis Mellanox Technologies 69 Rev 1 8 Disassembly and Disposal Figure 57 Mechanical Lifting Device Put the container base saved from the installation on the fork lift Raise the container base to 1 cm below the level of the shelf Move the chassis away from the rack and onto the container base Put wedges around the chassis to prevent the chassis from rolling off of the container base Move the chassis away from the rack wa NR Dispose of the Chassis in a legal and environmental way 6 1 2 Removing the Bottom Shelf 1 Remove all of the bolts that are holding the shelf to the rack 2 Remove the shelf 3 Remove all of the caged nuts 70 Mellanox Technologies 324 Port InfiniBand QDR Switch Platform Hardware User Manual Rev 1 8 6 2 Disposal According to the WEEE Directive 2002 96 EC all waste electrical and electronic equ
40. cal 3919 80W including Max 45 C 755 mm 310 685 mm configuration QSFP active cables at 2W Min 10 C 16 U forthe 482 6 mm Typical 3595 80W including chassis and 90 kg 199 Ibs empty QSFP active cables at 1W 1U for the configuration Typical 3090 43W passive shelf cables The switch ships in a minimum base configuration plus additional modules depending on the cho sen customer configuration Optional modules include e Leaf boards e Management modules Figure 4 shows the connector and spine sides fully populated Mellanox Technologies 13 Rev 1 8 Overview Figure 4 S5300 Switch Views e e S o AL LL all o e 8 AC1 AC2 AC3 AC4 AC5 1 1 CAL 1 1 Fi F2 j O 14 Mellanox Technologies 324 Port InfiniBand QDR Switch Platform Hardware User Manual Rev 1 8 1 2 Features List e 324 QDR 40Gb s ports in a 29U switch e IBTA 1 21 compliant SDR DDR QDR link speed e Congestion control e Adaptive routing e Port mirroring e Chassis High Availability e sMB High Availability Mellanox Technologies 15 Rev 1 8 Hardware 2 Hardware Installation Safety Warnings 1 Installation Instructions LA Read all installation instructions before connecting the equipment to the power source 2 Bodily Injury Due to Weight Use enough people to safely lift this product LA lt 40 Ibs 40 70 Ibs 70 121 Ibs gt 121 Ibs lt 18 kgs
41. codes lectriques locaux et nationaux 14 Codes d installation pays Pour l Am rique du Nord l quipement doit tre install conform ment aux L appareil doit tre install selon l ancienne version des codes lectriques nationaux du A sp cifications du Code Electrique National Am ricain et du Code Electrique Canadien Mellanox Technologies 89 Rev 1 8 15 Interconnexion des unites Les c bles de branchement l unit RS232 et les interfaces Ethernet doivent tre certi fies UL de type DP 1 ou DP 2 Note lorsqu il existe dans un circuit non LPS Protection contre la surintensit Un appareil de protection r pertori facilement accessible contre la surintensit du circuit de branchement et calibr 20A doit tre incorpor dans le c blage lectrique du b timent gt 16 Exposition au rayonnement grave Mise en garde l utilisation de commandes ou de r glages ou l ex cution de proc dures autres que ce qui est sp cifi dans les pr sentes peut engendrer une exposition au rayonnement grave PRODUIT LASER DE CLASSE 1 et r f rences aux normes laser les plus r centes CEI 60 825 1 1993 A1 1997 A2 2001 et NE 60825 1 1994 A1 1996 A2 2001 17 S assurer que les enceintes sont appropri es Des enceintes lectriques m caniques et incendie adapt es doivent tre fournies par le fabricant du produit final ou par l utilisateur final gt 18 Cordons lectriques CA
42. conductores hilo de 1 0 mm2 como minimo 300 voltios nominal con cobertura protectora aislante de PVC El cable debe tener un enchufe moldeado con capuch n de 250 voltios nominal 10 A 15 Fuga gt 3 5 mA M ADVERTENCIA Alta corriente de fuga Es esencial efectuar la conexi n a tierra antes de conectar la alimentaci n 16 A adir conexi n a tierra a Antes de conectar el dispositivo a la l nea de alimentaci n los tornillos del terminal de la puesta a tierra de protecci n del dispositivo se deben conectar a la puesta a tierra de protecci n de la instalaci n del edificio Informaci n de conexi n a tierra La instalaci n del edificio deber prover un medio para la conexi n con la puesta a tierra de protecci n y un t cnico de servicio deber conectar permanentemente el equipo a dicho medio de conexi n Un T CNICO DE SERVICIO comprobar si la toma el ctrica de la que se suminis trar corriente al equipo provee una conexi n con la puesta a tierra de protecci n del edificio De no ser as el T CNICO DE SERVICIO se encargar de instalar un CON DUCTOR DE CONEXI N A TIERRA DE PROTECCI N del terminal de puesta a tierra de protecci n separado al conductor de tierra de protecci n del edificio El equipo se instalar en un rea donde haya conexi n equipotencial como por ejemplo un centro de telecomunicaciones o una sala de computadoras dedicada 17 C digos de instalaci n M Este dispositivo se d
43. cted by links to each spine module Each spine has one status LED for the spine and 36 status LEDs The 36 LEDs on each spine are divided by the number of leafs and the result X is the number of ports from each leaf that is connected to the spine 9 spines must be installed and working to ensure that full BW exists between nodes Should a leaf be removed then X number of LEDs will turn off on each of the spines The status LEDs for the spine and their descriptions are shown in Table The LEDs indicate as fol lows Figure 8 Spine Status LEDs 1921 2325 2729 31 33 35 DODDODODOOO 00000000000000 99990900 09 0000 0000000 Spine Status Fan Status Spine Leaf IB Connection Status 2 1 3 1 Status LED The Spine Status indicator LED has the following led assignment Table 7 Spine Status LED LED Description Off No power to the spine Solid Green Spine is up and running Flashing Green Spine is powering up Orange Non fatal error Red Fatal error The leaf board status on each spine displays the condition of the connection between the spine and each leaf There is a minimum of one LED per each leaf per each spine Each spine has leaf status LEDs The leaf LEDs on each spine indicate as follows Mellanox Technologies 23 Rev 1 8 Hardware The Spine to leaf board Status indicator LED has the following led assignment Table 8 Spine to Leaf IB Link Status LED Description
44. d running Flashing Orange Error One or possibly more ports has just received a symbol error This LED shows symbol errors Possible causes for this are e bad cable e bad connection bad connector This LED lights up when one or more ports is receiving a symbol error The LED immediately goes off until the next symbol error is received 2 1 2 3 UID LED Switch Identifier The UID LED is a debug feature that will become available to customers in the near future For details please contact Mellanox Technologies support 2 1 2 4 Leaf Board Port Connector LED Assignment Above the ports are two LEDs one for the upper port and one for the lower port V The fol lowing table shows the port status according to the LED indication Table 6 Connector Physical and Logical Link Indications LED Description Off No power to the port Solid Green Logical link up Flashing Green Data activity flashing speed data transfer speed Orange Physical link up Flashing Orange A problem with the physical link 22 Mellanox Technologies 324 Port InfiniBand QDR Switch Platform Hardware User Manual Rev 1 8 SDR DDR QDR and or the link width 1X or 4X The speed and link width config gt The switch does not provide a visual means that indicates the port speed configuration yo urations can be retrieved using management software 2 1 3 Spine Board LED Indicators Each leaf board is conne
45. diation Exposure Caution Use of controls or adjustment or performance of procedures other than those specified herein may result in hazardous radiation exposure 18 Mellanox Technologies 324 Port InfiniBand QDR Switch Platform Hardware User Manual Rev 1 8 CLASS 1 LASER PRODUCT and reference to the most recent laser standards IEC 60825 1 2007 03 and EN 60825 1 2007 19 Do Not Use the Switch as a Shelf or Work Space NS Caution Slide rail mounted equipment is not to be used as a shelf or a work space 20 WEEE Directive According to the WEEE Directive 2002 96 EC all waste electrical and electronic equipment EEE should be collected separately and not disposed of with regular household waste Dispose of this product and all of its parts in a responsible and environmentally ma friendly way Mellanox Technologies 19 Rev 1 8 Hardware 2 1 LED Status Indicators The LEDs are placed on the chassis for the convenience of the IT manager NV 4 We recommend that all of the chassis sub systems be maintained and managed through the management software 2 1 1 Power Supply Unit LEDs Each Power Supply Unit has the following indicator LEDs Figure 5 Power Supply Unit Status Indications De AC OK FAIL OK AC When lit this LED indicates input voltage between 100 and 240 Volts DC FAIL When lit this LED indicates a fault in the power supply DC OK When lit t
46. dom Vibration EU IEC 60068 2 29 Shocks Type I II EU IEC 60068 2 32 Fall Test ISO 7779 ETS 300 753 75 8 db A Scalability and Perfo rmance Replaceable Parts Switching Performance Addressing Switching Capacity Simultaneous wire speed any port to any port 48K Unicast Addresses Max per Subnet 16K Multicast Addresses per Subnet 26 Tb s Leafs Power Supplies Leaf Fan Modules Spine Fan Mod ules Spines Management Modules Up to 18 leafs 18 ports each 6 Power Supplies standard of of which one is redundant 4 Leaf Fan Modules 9 Spine Fan Modules 2 available 1 required for oper ation 80 Mellanox Technologies 324 Port InfiniBand QDR Switch Platform Hardware User Manual Rev 1 8 A 2 EMC Certifications The list of approved certifications per chassis in different regions of the world is located on the Mellanox Website at www mellanox com related docs user_manuals Regulatory_and_Compliance_Guide pdf EMC Statements are also in the Regulatory and Compliance Guide Mellanox Technologies 81 Rev 1 8 Appendix B Calculating the Weight of a Customized Chassis The weight of a customized chassis can be calculated for any possible customization as follows Take the weight of a chassis with e all fans modules e all power supplies The weight of the IS5300 chassis configured above is 154kg To this add of spines 3 73 of leafs 2 67
47. e switch platform pletement le module en cause Il faut de brancher toutes les ali mentations stabilise es 3 Check the Status LEDs on all of the management modules and confirm that all of the LEDs show status lights consistent with normal operation A A Any yellow or red status LEDs on any of the management modules is cause for con A W cern and must be dealt with immediately gt gt 4 Check that none of the LEDs on the spines are yellow N It can take up to 5 minutes to boot up the system During this time the status LEDs may be RED Turn off the system if any LEDs remain red for more than 5 minutes 5 Check that the Leaf status LED Fan status LED and Spine status LED in the spines are all green Figure 41 Spine Module Fan LED 10000000000000001 2 e 19 21 2325 27 29 31 33 35 DODODODOO OODDO0O OOO 20 22 24 26 28 30 32 34 36 Status LED Leaf connection LEDs 3 7 InfiniBand QSFP Cable Installation The switch uses industry standard QSFP InfiniBand cables which are available from several ven dors The standard QSFP cables support full 40 40Gb s QDR 20 20Gb s DDR and 10 10Gb s SDR bidirectional wire speed of the switch ports All InfiniBand QSFP connections are made Mellanox Technologies 55 Rev 1 8 Installation to the leaf boards Each leaf has 18 InfiniBand QSFP connectors in two rows which are numbered 1 18 a If maximum cable lengths are exceeded data tr
48. ebe instalar conforme a la versi n m s reciente de los c digos el ctricos nacionales del pa s en cuesti n En Am rica del Norte el equipo se debe instalar de acuerdo con las disposiciones vigentes del C digo El ctrico Nacional de los EE UU y del C digo El ctrico de Canad 18 Interconexi n de unidades dh Los cables para la conexi n con las interfaces RS232 y Ethernet de la unidad deben estar homologados por UL tipo DP 1 o DP 2 Nota cuando residen en circuito no de tipo LPS Protecci n contra sobrecargas Al cableado del edificio se debe incorporar un disposi tivo de protecci n contra sobrecargas de circuito derivado de f cil acceso con una cor riente nominal de 20 A 96 Mellanox Technologies 324 Port InfiniBand QDR Switch Platform Hardware User Manual Rev 1 8 19 Exposici n a niveles de radiaci n peligrosos Precauci n el uso de controles o ajustes o la realizaci n de procedimientos distintos de los que aqu se especifican podr an causar exposici n a niveles de radiaci n peligrosos PRODUCTO L SER DE CLASE 1 y referencia a las normas de l ser m s recientes IEC 60825 1 2007 03 y EN 60825 1 2007 20 Directiva sobre RAEE Conforme a la Directiva 2002 96 CE sobre RAEE todos los residuos de equipos el c tricos y electr nicos EEE se deben recolectar por separado y no se deben eliminar junto con residuos dom sticos Al deshacerse de este producto y de todas sus partes h galo de u
49. ed When the button is held down for 15 seconds the management module is reset and the password is deleted You will then be able to enter without a password and make a new password for the user admin Mellanox Technologies 29 Rev 1 8 Installation 3 Installation d This chassis can be installed in standard 19 racks that have depths between 65cm and 80cm between the vertical supports of the rack A Installation and initialization of the chassis is a simple process requiring attention to the normal mechanical power and thermal precautions for rack mounted equipment Your Chassis will be shipped in two packages one with the all of the leafs leaf package that are ordered and an extra management module should it be ordered and the second package chassis package with all of the rest of the parts The chassis requires initial configuration to get the chassis and Fabric management up and running through remote management See the Installation Guide that is packed in the box for the instruc tions to make the initial configuration This unit is intended for installation in a Restricted Access Location A restricted L access area can be accessed only through the use of a special tool lock and key or M other means of security 3 1 Environmental and Safety Recommendations The following are Mellanox recommendations Y Recommended ambient temperature in the System room is 20 5 C Recommended humidity ranges is 40
50. estapelt werden Wenn das Chassis herun terf llt kann es zu Verletzungen und Besch digungen an Ger ten f hren 4 Redundanter Stromversorgungsanschluss Elektrische Gefahr Stromversorgung Betreiben Sie das Produkt nicht wenn diese Abdeckung nicht sicher Dieses Produkt verf gt ber eine Abdeckung ber dem Bereich f r die redundante A festsitzt oder entfernt wurde 5 Bei Gewitter Elektrische Gefahr Arbeiten Sie w hrend eines Gewitters und Blitzschlag nicht am Ger t schlieBen Sie keine Kabel an oder ab 6 Anschlie en Trennen von InfiniBand Kupferkabel an die Anschl sse angebracht bzw davon getrennt werden Lesen Sie die speziellen InfiniBand Kupferkabel sind schwer und nicht flexible Deshalb miissen sie vorsichtig Ay Warnungen und Anleitungen des Kabelherstellers 7 Rack Montage und Wartung sichtsma nahmen zu ergreifen um die Stabilit t des Systems zu gew hrleisten Im Wenn dieses Produkt in einem Rack montiert oder gewartet wird sind besondere Vor A Allgemeinen sollten Sie das Gestell von unten nach oben mit Ger ten f llen Mellanox Technologies 91 Rev 1 8 8 Ger teinstallation Diese Ger t sollte nur von geschultem und qualifiziertem Personal installiert ausge tauscht oder gewartet werden gt 9 Ger teentsorgung Die Entsorgung dieses Ger ts sollte unter Beachtung aller nationalen Gesetze Bestim mungen erfolgen gt 10 Regionale und nationale elektrische Bestimmunge
51. hat the system remains stable In general you should fill the rack with equip ment starting from the bottom to the top 10 Equipment Installation This equipment should be installed replaced and or serviced only by trained and qual ified personnel 11 Proper Enclosure A suitable electrical mechanical and fire enclosure shall be provided by the end prod uct manufacturer and or the end user 12 Equipment Disposal Disposal of this equipment should be in accordance to all national laws and regula LA tions 13 Local and National Electrical Codes This equipment should be installed in compliance with local and national electrical 4 codes Mellanox Technologies 17 Rev 1 8 Hardware 14 UL Listed and CSA Certified Power Supply Cord Leakage gt 3 5mA For North American power connection select a power supply cord that is UL Listed and CSA Certified 3 conductor 16 AWG terminated with a molded plug rated at LA 125 V 13 A with a minimum length of 1 5m six feet but no longer than 4 5m For European connection select a power supply cord that is internationally harmonized and marked lt HAR gt 3 conductor minimum 1 0 mm2 wire rated at 300 V with a PVC insulated jacket The cord must have a molded plug rated at 250 V 10 A LA Warning High leakage current Earth connection essential before connecting supply 15 Add GND connection information Before connecting this device to the power line the
52. he chassis to the shelf The weight of the switch is supported from underneath the unit by the shelf 32 Mellanox Technologies 324 Port InfiniBand QDR Switch Platform Hardware User Manual Rev 1 8 This chassis can be installed in standard 19 racks that have depths between 65cm and 80cm between the vertical supports of the rack Make sure that a fully populated rack including cables will have sufficient air flow for cooling d Choose a rack which is able to support the mechanical and environmental characteris tics of a fully populated switch chassis A 3 5 1 Starting with the Rack Mellanox recommends that you remove both sides of the rack to make the installation easier LA You will need a fork lift to move and insert the chassis into the rack This chassis can be installed in 19 racks with a minimum depth of 100 cm This depth is the min imum necessary to allow enough room for cable placement without affecting ventilation through the chassis The switch platform uses 17U of rack space in a standard 19 rack The switch ships from the fac tory with mounting holes on the spine side There are upper brackets to connect the leaf side to the rack near the top of the chassis and there are two lock down bars to secure the chassis to the shelf The weight of the switch is supported from underneath the unit by a shelf The rack may need to be modified to accommodate the 5300 chassis The distance between the vertical
53. his LED indicates that the output from the power supply is 48 VDC A The PSUs are on the spine side of the chassis behind two cover panels The plugs for these PSUs are on the leaf side of the chassis As 20 Mellanox Technologies 324 Port InfiniBand QDR Switch Platform Hardware User Manual Rev 1 8 Figure 6 PSU Cover On and Off Fi F2 lt F1 Fab US e o o ali ul adi WW 1 H amp J U 185300 185300 ei E 2 185300 2 1 2 Leaf Board LED Indicators Figure 7 Leaf Board Led Indicators 2 1 2 1 Status LED Each leaf board has a Status LED on the far left of the leaf This LED has the following meanings according to the LED status The Leaf Status indicator LED A has the following led assignment Table 4 Leaf Status LED LED Description Off No power to the Leaf Solid Green Leaf is up and running Flashing Green Leaf is powering up Orange Non fatal error This color LED needs troubleshooting but does not require chassis shutdown Mellanox Technologies 21 Rev 1 8 Hardware Table 4 Leaf Status LED LED Description Red Fatal error 2 1 2 2 Bad Port LED Lt The Bad Port indicator is located on the left side of the spine The following Bad Port conditions are possible Table 5 Bad Port LED Configurations LED Configuration Description Off OK All ports are up an
54. ideada para instalar en lugares de acceso restringido 4 Sobrecalentamiento No se debe utilizar el equipo en un rea con una temperatura ambiente superior a la m xima recomendada 45 C 113 F Adem s para garantizar una circu laci n de aire adecuada se debe dejar como m nimo un espacio de 8 cm 3 pul gadas alrededor de las aberturas de ventilaci n gt 5 Apilamiento del chasis a Los chasis no se deben apilar sobre otros equipos La caida del chasis podria causar lesiones corporales as como da os al equipo 6 Conexi n de fuente de alimentaci n redundante peligro de descarga el ctrica Este producto incluye una fuente de alimentaci n redundante o en su lugar una vac a Si se dispone de una fuente de alimentaci n vac a no utilizar el producto si su tapa est quitada o no est bien cerrada 7 Cuando hay rayos peligro de descarga el ctrica No utilizar el equipo ni conectar o desconectar cables durante per odos de activ idad de rayos 94 Mellanox Technologies 324 Port InfiniBand QDR Switch Platform Hardware User Manual Rev 1 8 8 Conexi n y desconexi n del cable Copper InfiniBand Dado que los cables de cobre InfiniBand son pesados y no son flexibles su con exi n a los conectores y su desconexi n se deben efectuar con mucho cuidado Para ver advertencias o instrucciones especiales consultar al fabricante del cable 9 Montaje y mantenimiento de bastidores Al
55. ig no power enable L16 Disconnect all cables connected to the leaf Push the latch to unlock the ejector from the chassis Open the ejector until it is 90 degrees from the leaf Pull out on the leaf ie ee tS Figure 47 Ejector Latch Pull the leaf out of the chassis Leaf Push the latch release a Ejector Note The board is short therefore do not let go of it while sliding it out Mellanox Technologies 61 Rev 1 8 Insertion and or Hotswap Extraction Figure 48 Leaf Release Push here to release the latch Pull the ejector to remove the leaf no AAAs zz 5 2 2 Inserting a Leaf Board Start with the latch fully open that is perpendicular to the front panel of the leaf Carefully set the leaf board into the side guide rails and slowly slide the board into the chassis Catch the hooks onto the vertical bar and push the latch shut 5 3 Spine Boards When hotswapping any of the units it is necessary to wait 1 minute after removing the defective part before inserting the new part This is necessary so that the management i module will start a new cycle checking through the leafs and spines for the FW ver ae sions Each spine has a pair of ejectors that lock the board in place and serve as levers for seating or extracting see Figure 49 5 3 1 Extracting a Spine Board 1 Run the spine shut down command no power enable lt
56. inged extension is sitting on the shelf extension 46 Mellanox Technologies 324 Port InfiniBand QDR Switch Platform Hardware User Manual Rev 1 8 11 Push the chassis from the container to the shelf Figure 31 Fork Lift Hinged extension Y Save the container pallet until you want to remove this chassis It will be necessary for the removal and disposal procedures Figure 32 Face Plate Mounting Bolt Locations Fi F2 e e e e E e 0 185300 185300 Mellanox 7 Holes in the faceplate for mount ing on the rack The holes are separated by 4U units i ji O CH Mellanox Technologies 47 Rev 1 8 Installation 12 Slide the chassis onto the shelf and determine the location of the upper brackets on the vertical supports on the connector side of the chassis 13 Slide the chassis out just far enough to install the upper brackets Figure 33 Upper Brackets and Offset Location 48 Mellanox Technologies 324 Port InfiniBand QDR Switch Platform Hardware User Manual Rev 1 8 Figure 34 Upper Bracket Installation This hole is 60cm up from the top of the shelf 14 Screw the upper brackets onto the vertical supports and tighten in place You will need the socket wrench with both extensions to tighten these bolts 15 Slide the chassis onto the shelf until the face plate of the chassis touches the vertical
57. ipment EEE should be collected separately and not disposed of with regular household waste Dispose of this product and all of its parts in a responsible and environmentally friendly way Mellanox Technologies 71 Rev 1 8 Switch Management Tools 7 Switch Management Tools This chapter describes the management module and tools available for Out of Band management of the switch system via FabricIT EFM d There are 2 Ethernet ports 1 for each management module that each get connected to Ethernet switches These switches must be configured to 10 100M auto negotiation gt The IS5300 switch is pre installed with a license supporting of up to 648 nodes If the fabric includes more than 648 nodes you may need to purchase Mellanox s Unified Fabric Manager UFMTM software package OpenSM running on the switches supports up to 648 nodes If the fabric includes more than 648 nodes you may need to purchase Mellanox s Unified Fabric Manager UFM software pack age The managed switch system includes the following software components Embedded OS e Chassis manager and system BIST e SNMP agent 3rd party tool integration e GUI e Subnet Manager SM e Remote logging e SSH telnet e Secured access in band and out band IPv4 IPv6 network stack The chassis manager will give the user access to e Switch temperatures e Power supply voltages e Fan unit information e Power unit information e Flash memory e Moni
58. is necessary so that the management module will start a new cycle checking through the leafs and spines for the FW ver sions This switch platform supports Hotswap capabilities for the e Power supply units e Leaf boards e Spine boards e Leaf fan module e Spine fan module e Management modules 5 1 Power Supply Units When hotswapping any of the units it is necessary to wait 1 minute after removing the defective part before inserting the new part This is necessary so that the management module will start a new cycle checking through the leafs and spines for the FW ver sions A PSU Power Supply Unit can be extracted without bringing down the system as long as no more than one PSU is bad The power required to run the switch system is equally divided between all of the working PSUs 5 1 1 Extracting and Inserting the Power Supply Unit With all of the power supplies installed the system is in the redundant configuration any single PSU may be extracted without bringing down the system To extract a PSU 1 Remove the power cord from the power supply unit Note which power cord it is according to the AC numbering Mellanox Technologies 59 Rev 1 8 Insertion and or Hotswap Extraction Figure 45 Power Cord Top Bar 2 On the spine side of the chassis remove the cover to the power supply unit for the non work ing PSU Figure 46 Power Supply Handle Latch 3 Grasping the handle with one ha
59. itch Platform Hardware User Manual 1ews QSFP Connector Male and Female Vi Figure 58 18 35 Top View into Rear of Connector GNB AX n 1Xtp GND TX3n TX3p GND LPMode Vcc1 VecTx IntL ModPrsL GND RX4p RX4n GND RX2p RX2n GND Bas N e kel GND TX2n TX2p GND TX4n TX4p GND ModSelL ResetL VecRx SCL 18 35 View into Front of Cage N Co gt O1 OO NS 00 io aNd me diXH aNd UEXH dexu aNd vas 198 Xy99A 19S9H TISSPON IND dex upXL IND dzXL uzXL aNd 85 Mellanox Technologies Rev 1 8 Appendix E Replacement Parts Ordering Numbers Table 16 Replacement Parts Ordering Numbers Part Description OPN 324 port QDR capable modular chassis includes fans MIS5300Q 6DNC and power supplies RoHS5 Power supply unit PSU MTP005001 Power supply blank MTMO005001 Leaf board unit 18 port QDR MIS5001QC Modular Switch Family Leaf Blank MTM0053004 Spine board unit for QDR Switch system MIS5002QC Spine board blank MTM005002 PPC460 Management Module MIS5600MDC Management module blank MTM005003 Fan unit for Chassis Leaf side MTF005001 Fan unit for Chassis Spine side MTF005002 Modular Switch Family Management Blank MTM005003 Rack Installation Kit for IS5600 SX6536 Series MTR005600 Cable Management Device Set for IS5600 SX6536 MTR005
60. itch Shut Down Procedures 68 5 6 1 To shut down the chassis run the following command twice 68 5 6 2 To shut down a leaf run the following command 68 5 6 3 To shut down a spine run the following command 68 Chapter 6 Disassembly and Disposal 69 6 1 Disassembling the Chassis 69 6 1 1 Removing the Chassis 69 6 1 2 Removing the Bottom Shelf 70 6 2 Disposal 71 Chapter 7 Switch Management Tools 72 7 1 InfiniBand Subnet Manager 73 7 2 Fabric Diagnostics with UFM Diag 73 7 3 Accessing the CPU via the Ethernet Connector 74 7 4 Upgrading Software 74 Chapter 8 TroubleShooting 75 8 1 Power Supply Unit 75 8 2 Leaf Board 75 8 3 Management Module 76 8 3 1 Yellow Status LED for the Chassis on the Management Module is Lit 76 8 3 2 Yellow LED for the Leaf Fan on the Management Module is Lit 76 8 3 3 Yellow LED for the Spine Fan on the Management Module is Lit 77 8 4 SpineBoard 77 8 5 FabricITSW 77 Appendix A Specification Data 79 A 1 Specifications 79 A 2 EMC Certifications sl Appendix B Calculating the Weight of a Customized Chassis 82 Appendix C Calculating the Power of a Customized Chassis 83 Appendix D QSFP Interface 84 Appendix E Replacement Parts Ordering Numbers 86 Appendix F Avertissements de s curit d installation French 88 Appendix G Installation Sicherheitshinweise German 91 Appendix H Advertencias de seguridad para la instalaci n Spanish 94 4 Mellanox Technologies 324 Port InfiniBand QDR Switch Platfor
61. lanox Technologies 43 Rev 1 8 Installation Figure 26 Putting the Chassis in the Rack The chassis is screwed down to the pallet on both the spine side and the leaf side Figure 27 Location for the Lock down Bar Bottom of the o chassis 44 Mellanox Technologies 324 Port InfiniBand QDR Switch Platform Hardware User Manual Rev 1 8 2 Unscrew the lock down bars 3 Screw on the two Upper Bracket offsets onto the chassis using nine flat head screws for each offset Figure 28 Place the Upper Bracket Offset 4 Screw on the shelf extension using two bolts with flat washers Figure 29 Attach the Shelf Extension F 0 e 5 If you are installing the cable management system place 10 caged nuts on the other side of the rack in the vertical supports 6 Place caged nuts in all of the locations specified in Figure 14 The black holes show where to place caged nuts the red holes show the location of the upper brackets on the leaf side Mellanox Technologies 45 Rev 1 8 Installation Figure 30 Caged Nut Placement by U Numbers These are for the cable holder 60 cm Spine side Leaf Side 7 Place the chassis in front of the rack and as close as possible to the rack 8 Raise the chassis so that it is 5cm above the shelf in the rack 9 Raise the hinged extension on the container floor 10 Lower the chassis until the h
62. le holder Figure 38 Cable Holder Left side rack Top side Place the Cable holder next to the rack on the connector side of the chassis and identify the 1 holes where the caged nuts are to be placed d The cable holders should go to the outside of the vertical supports aa 2 Set the bottom of the cable holder at the level of the shelf 52 Mellanox Technologies 324 Port InfiniBand QDR Switch Platform Hardware User Manual Rev 1 8 3 Screw the cable holder onto the rack using the screws provided 4 Repeat steps 1 3 for the second cable holder 3 5 5 Ground Connections Make sure to connect the ground post to a valid electrical ground Use a grounding lug and a ground wire of sufficient capacity to safely convey a potential discharge A ground wire of AWG 6 or 4mm diameter is recommended for grounding this device The chassis is concurrently grounded through each of the PSUs Only connect the PSU cords to properly grounded outlets Do not rely on the PSU grounds It is absolutely necessary to connect the grounding post Make sure the con nections are solid and permanent If you choose to not use the ground screw make sure that the rack is properly grounded and that there is a valid ground connection between the chassis of the switch and the rack Test the ground using an Ohm meter Figure 39 Ground Connection Fi F2 gt 4 0 Le 155300 Mellanox 155300 Canet 00000000
63. m Hardware User Manual Rev 1 8 Table of Figures Figure 1 Generic Product Label 12 Figure 2 Product Label Tab Location 12 Figure 3 Management Module MAC Address Location 12 Figure 4 5300 Switch Views 14 Figure 5 Power Supply Unit Status Indications 20 Figure 6 PSU Cover On and Off 21 Figure 7 Leaf Board Led Indicators 21 Figure 8 Spine Status LEDs 23 Figure 9 Spine Side Panel Display Status Indications 25 Figure 10 Management Module Status Indications 26 Figure 11 Port Numbering 27 Figure 12 Top and Bottom Ports 27 Figure 13 Management Module Interfaces 27 Figure 14 Reset Button 29 Figure 15 Distance Between the Vertical Supports 34 Figure 16 Installation Kit Parts 36 Figure 17 Container Screws 37 Figure 18 Vertical Rack Supports Dimension 39 Figure 19 Adjustable Shelf Brackets 39 Figure 20 Top of Shelf Bracket 40 Figure 21 Placing the Shelf Bracket 40 Figure 22 Caged Nut Locations for the Shelf Brackets 41 Figure 23 Shelf Brackets 41 Figure 24 Place the Lock Down Bar on the Shelf 42 Figure 25 U Numbering Above Shelf 43 Figure 26 Putting the Chassis in the Rack 44 Figure 27 Location for the Lock down Bar 44 Figure 28 Place the Upper Bracket Offset 45 Figure 29 Attach the Shelf Extension 45 Figure 30 Caged Nut Placement by U Numbers 46 Figure 31 Fork Lift 47 Figure 32 Face Plate Mounting Bolt Locations 47 Figure 33 Upper Brackets and Offset Location 48 Figure 34 Upper Bracket Installation 49 Mellanox
64. m is up and running the status of the Yellow System warning Attention needed such as overheating chassis Red System not operational Diagnostics fail CPU hang HW fail Overheat critical Blinking Yellow System booting Restore factory defaults in progress PSU STATUS Off No power Green Green Normal operational Red PS fault detected User should check individual power supplies for fault indications SPINE FANS Off No power to fan Green STATUS Green Nominal operational Yellow Non fatal failure Red Fatal failure Turn the chassis off and then troubleshoot LEAF FANS Off No power to fan Green STATUS Green Nominal operational Yellow Non fatal failure Red Fatal failure Turn the chassis off and then troubleshoot MASTER Off no power or this management module is not installed Green Green Management module is operating as a master i e the other management module is a slave Yellow Management module is operating as a slave i e the other man agement module is a master 2 1 6 Port Connector Interfaces The connector side of the switch has 18 leaf boards and each leaf board has 18 QSFP ports The ports on each leaf board are placed in two rows 9 ports to a row The ports are labelled as shown in Figure 11 The bottom row ports are flipped from the top row See Figure 12 26 Mellanox Technologies 324 Port InfiniBand QDR Switch Platform Hardware User Manual Rev 1 8 Figure 11 Port Numbe
65. mbers and their revisions 7 2 Fabric Diagnostics with UFM Diag UFM Diag is a plug amp play software for fee within FabricIT EFM displaying and filtering all iden tified systems and nodes within the fabric UFM Diag includes a complete set of tools for fabric wide diagnostics to check node node and node switch connectivity and to verify routes within the fabric Mellanox Technologies 73 Rev 1 8 Switch Management Tools Advanced filtering allows creating filtering rules on a system wide basis between nodes or port connections based on traffic patterns and user assigned system names GUIDs 7 3 Accessing the CPU via the Ethernet Connector Once the initial configuration is completed the management tools can be accessed through e SSH e Telnet WEB e SNMP XML 7 4 Upgrading Software The new software and firmware update is available to the user from the Mellanox Support website Copy the update to a known location on a Remote server within your LAN Use the CLI or the GUI in order to perform the Software upgrade For further information please refer to the FabricIT EFM user manual If FabricIT EFM is updated and the FW image in the leafs and spines of the chassis is gt an earlier version than the minimum that the new version of the software can work with then the chassis management system may require up to 45 minutes to update all of the FW images in all of the leafs and spines 74 Mellanox Technologies
66. minutes to boot up the system During this time the status LEDs may be RED Turn off the system if any LEDs remain red for more than 5 minutes As the power is turned on you should observe the following conditions for normal operation Mellanox Technologies 57 Rev 1 8 Chassis Power Up Power Supply Unit s AC OK and DC OK indicators are ON and FAIL indicators are OFF 2 There is a green Status LED per spine board per leaf board and per management module that indicates power supplies are good 3 Spine Board indicators will display status of internal links to the installed leaf boards All PHY links to existing leaf Boards should be ON 4 Check the Spine LEDs and make sure they coincide with Table 43 Figure 43 Spine Side Panel Display Status Indications AAA AA O STATUS PSU SPINE LEAF MGT 1 MGT 2 STATUS FANS FANS STATUS STATUS 5 Check the Spine LEDs and make sure they coincide with Table 44 Figure 44 Management Module Status Indications for Normal Operation DI A A 00 0 9 NN OU 58 Mellanox Technologies 324 Port InfiniBand QDR Switch Platform Hardware User Manual Rev 1 8 5 Insertion and or Hotswap Extraction Before starting any procedure on the 185300 series Switch system put an ESD prevention wrist strap on your wrist and connect to the 185300 series Chassis When hotswapping any of the units it is necessary to wait 1 minute after removing the defective part before inserting the new part This
67. n Dieses Ger t sollte unter Beachtung der regionalen und nationalen elektrischen Bestimmungen installiert werden 11 Richtigen Schutz sicherstellen Geeigneter elekrischer mechanischer und Feuerschutz sind vom Hersteller des Endprodukts oder dem Endbenutzer bereitzustellen gt 12 Strahlenkontakt Achtung Nutzung von Steuerungen oder Einstellungen oder Ausfiihrung von Proze duren die hier nicht spezifiziert sind kann zu gef hrlichem Strahlenkontakt fiihren Klasse Laserprodukt und Referenzen zu den aktuellsten Lasterstandards ICE 60 825 1 1993 A1 1997 A2 2001 und EN 60825 1 1994 A1 1996 A2 2001 13 UL und CSA Certified Netzkabel UL Listed and CSA Certified Power Supply Cord F r Nordamerika Stromanschluss w hlen Sie ein Netzkabel das UL und CSA Certi fied 3 Leiter 18 AWG mit einem angespritztem Stecker bewertet bei 125 V 15 mit einer Mindestl nge von 1 5 m Six Feet aber nicht mehr als 4 5 m F r die europ ischen Zusammenhang w hlen Sie ein Netzkabel das international harmonisiert und der Aufschrift lt HAR gt 3 Leiter mindestens 0 75 mm2 Draht bewertet mit 300 V mit einem PVC Mantel isoliert Das Kabel muss eine angespritztem Stecker bewertet bei 250 V 10 A 92 Mellanox Technologies 324 Port InfiniBand QDR Switch Platform Hardware User Manual Rev 1 8 14 Ableitstrom gt 3 5mA LEAKAGE gt 3 5mA WARNUNG Hohe Ableitstrom Earth Verbindung bevor Sie die
68. na manera responsable y respetuosa con el medio ambiente Mellanox Technologies 97
69. nd 26 GND GND 13 2 Tx2n Transmitter Inverted Data Input 27 ModPrsL SDA 12 3 Tx2p Transmitter Non Inverted Data Input 28 Int SCL 11 4 GND Ground 29 VocTx Veo Rx 10 5 Tx4n Transmitter Inverted Data Input 30 Veet Reset __2 6 Tx4p Transmitter Non Inverted Data Input 21 LPMode ModSelL 1 GND Ground 32 GND GND 7 8 ModSelL Module Select 3 Tx3p Tx4p 9 ResetL Module Reset a En A 10 Vcc Rx 3 3 V Power supply receiver 36 ae gt 3 11 SCL 2 wire serial interface clock p P 37 Dis BAr 2 12 SDA 2 wire serial interface data 38 GND GND 13 GND Ground 14 Rx3p Receiver Non Inverted Data Output 15 Rx3n Receiver Inverted Data Output 16 GND Ground 17 Rxlp Receiver Non Inverted Data Output 18 Rxin Receiver Inverted Data Output 19 GND Ground 20 GND Ground 21 Rx2n Receiver Inverted Data Output 3 22 Rx2p Receiver Non Inverted Data Output 3 23 GND Ground 24 Rx4n Receiver Inverted Data Output 3 25 Rx4p Receiver Non Inverted Data Output 3 26 GND Ground 27 ModPrsL Module Present 28 IntL Interrupt 29 Vcc Tx 3 3 V Power supply transmitter 30 Vcc 1 3 3 V Power Supply 31 LPMode Low Power Mode 32 GND Ground 33 Tx3p Transmitter Non Inverted Data Input 34 Tx3n Transmitter Inverted Data Input 35 GND Ground 36 Txlp Transmitter Non Inverted Data Input 37 Txin Transmitter Inverted Data Input 38 GND Ground 84 Mellanox Technologies Rev 1 8 324 Port InfiniBand QDR Sw
70. nd push the black latch release while pulling the handle out ward As the PSU unseats the PSU status indicators will turn off 4 Remove the PSU To insert a PSU 1 Make sure the mating connector of the new unit is free of any dirt and or obstacles 2 Insert the PSU by sliding it into the opening until a slight resistance is felt 3 Continue pressing the PSU until it seats completely The latch will snap into place confirming the proper installation Insert the power cord into the supply connector on the other side of the chassis 5 Replace the cover over the PSUs The green indicators should light If not extract the PSU and re insert it again 60 Mellanox Technologies 324 Port InfiniBand QDR Switch Platform Hardware User Manual Rev 1 8 5 2 Leaf Boards When hotswapping any of the units it is necessary to wait 1 minute after removing the defective part before inserting the new part This is necessary so that the management module will start a new cycle checking through the leafs and spines for the FW ver sions The leaf boards are numbered from top to bottom with corresponding numbers displayed to the outside of the leafs vertically along the side panel 5 2 1 Extracting a Leaf Board Each leaf board has an ejector that locks the board in place and serves as a lever for seating or extracting see Figure 56 1 Run the leaf shut down command no power enable lt module gt switch 1 Orca648 master conf
71. ng the Leaf Fan Module 1 Make sure the fan module is oriented correctly top side up Confirm that the location of the connector in the chassis will line up with the connector in the fan module 2 Slowly slide in the new leaf fan module A If the fan module stops before it goes in all of the way it is inserted incorrectly 3 Push the fan module until the latch engages 4 Make sure that the green leaf LED on the module comes on indicating that fan is running 5 4 2 Spine Fan Modules Each spine fan module contains two individual fans Should a single fan fail the Fan Status LED on the spine and on the management module will light indicating the necessity to replace the fan module Air flow through the spines is independent of the air flow through the leafs Each spine module has a fan module with two individual fans built in When a fan module is not functioning the status LED on the fan will light up Figure 53 Spine Fan Module RA AA AA AA e 19 21 2325 27 29 31 33 35 oono ogo DOU LD 20 22 2426 28 30 32 34 36 Fan Module Mellanox Technologies 65 Rev 1 8 Insertion and or Hotswap Extraction When a fan module is removed the indicator light will reset Figure 54 Fan Status LED on the Spine Module 5 4 2 1 Extracting the Spine Fan Module 1 Push the two blue latch buttons together while pulling the fan module out 5 4 2 2 Inserting the Spine Fan Module 1 Make sure the fan module is o
72. ot swapping a PSU should one fail Connecting the PSUs to different AC lines provides AC failover protection A system should continue to run and allow a hotswap of a defective PSU Should there not be enough power to keep all of the leafs running FabricIT EFM may power down some leafs If this happens it may be necessary to reboot the chassis once the defective PSU has been replaced The power system will divide the current consumption by the number of working PSUs Should one of the PSUs fail the total current consumption will then be divided by the remaining working PSUs When the failed PSU is hot swapped the new PSU will ramp up and pass its share of cur rent so that the total current is always divided by the number of working PSUs 54 Mellanox Technologies 324 Port InfiniBand QDR Switch Platform Hardware User Manual Rev 1 8 Figure 40 Multiple Power Inlets Electric Caution Notification CAUTION ACHTUNG ATTENTION Risk of electric shock and Gafahr des elektrischen Schocks Risque de choc et de danger energy hazard Entferrnen des Netzsteckers e lectriques Le de branchment The PSUs are all independent elnes Netzteils spannungsfrei d une seule alimentation stabi Um alle Einhieten spannungsfrei lise e ne de branch uniquement Disconnect all power supplies to zu machen sind die Netzstecker qu un module Alimentation ensure a powered down state aller Netzteile zu entfernen Stabilise e Pour isoler com inside of th
73. que le syst me reste stable En g n ral il faut remplir la baie avec du mat riel de bas en haut 88 Mellanox Technologies 324 Port InfiniBand QDR Switch Platform Hardware User Manual Rev 1 8 8 Fuite gt 3 5mA Leakage gt 3 5mA ATTENTION La connexion la terre des forts courants de fuite est essentielle avant le branchement de l alimentation LA Avant de brancher l appareil la conduite d alimentation les vis de protection la terre du terminal de l appareil doivent tre appliqu es l installation de protection la Terre du b timent 9 Forts Courants de Fuite High Leakage Current Attention Forts courants de fuite Il est essentiel de relier a la terre avant de brancher l alimentation 10 Ajouter une information de connexion la masse Connect a Valid Ground to this Device terre du terminal de l appareil doivent tre appliqu es l installation de protection la Avant de brancher l appareil la conduite d alimentation les vis de protection la A Terre du b timent 11 Installation du mat riel h Ce mat riel ne doit tre install remplac ou entretenu que par du personnel form et qualifi 12 Elimination du mat riel T limination de ce mat riel doit s effectuer dans le respect de toutes les l gislations et r glementations nationales en vigueur 13 Codes lectriques locaux et nationaux LA Ce mat riel doit tre install dans le respect des
74. riented correctly top side up Confirm that the location of the connector in the chassis will line up with the connector in the fan module Slowly slide in the new spine fan module 3 Push the fan module until as far as it will go make sure the locking latches engage 5 5 Management Module When hotswapping any of the units it is necessary to wait 1 minute after removing the defective part before inserting the new part This is necessary so that the management module will start a new cycle checking through the leafs and spines for the FW ver sions Before starting any procedure on the IS5300 series Switch system put an ESD prevention wrist strap on your wrist and connect to the 185300 series Chassis 5 5 1 Extracting a Management Module Management modules are located on the leaf side above the leafs There are two places to install the management modules Note Only one management module is required to run the switch system Each management module has a pair of ejectors that lock the board in place and serve as a lever for seating or extracting see Figure 56 1 Shut down the management module you wnat to replace using the folloing command no power enable lt module gt switch 1 Orca648 master config no power enable MGMT2 2 Disconnect all cables connected to the management module 66 Mellanox Technologies 324 Port InfiniBand QDR Switch Platform Hardware User Manual Rev 1 8 3 Push outward on the latches to unlock
75. ring 1 3 5 7 9 11 13 is 17 ARA A A AA O EA PEA ROS VA AAN AAA AA AO SAS AE AO AE SAA 2 4 6 8 1 0 E 14 16 18 Figure 12 Top and Bottom Ports eee 2 2 Air Flow These switches come with the air flow pattern of air entering through the spine side and exiting through the connector side 2 3 QSFP Cable Power Budget Classification All 185300 QSFP switches are designed for active cables with a max power per module of 2 0W This is power level 2 according to the QSFP Public Specification 2 4 Management Module Interfaces The switch system requires at least one management module The management module has five interfaces to connect to the 185300 They are e 1 12C port e 1 CONSOLE port this is an RS232 connector for connecting to a host machine e 1 MGT this is an Ethernet connector e 1 USB port e 1 RST reset button Figure 13 Management Module Interfaces CONSOLE MGT gt RST PSU S FANS L h h ON Mellanox Technologies 27 Rev 1 8 Hardware 2 4 1 12C This interface is for Debug and Troubleshooting only This interface is for FAEs only 2 4 2 CONSOLE The CONSOLE port is used during the installation process to configure the chassis for remote management Connect this port to a local host using the harness supplied with the chassis See the Installation Guide for the initial configuration procedure 2 4 3 MGT Management The MGT port is an Ethernet po
76. rt for remote management Any remote terminal connected to the Ethernet can then be used to manage the fabric and chassis Each Ethernet connector gets connected to Ethernet switches These switches must be configured to 10M 100M auto negotiation hb gt Initial configuration must be done on all of the management modules gt 2 4 4 USB The USB port can be used to upload new SW using any storage device that has a USB connector This interface is USB 2 0 2 4 5 Reset RST The Reset button resets the chassis management module when the button is pushed When the but ton is held down for 15 seconds the management module is reset and the password deleted DO NOT use a sharp pointed object such as needle or push pin for pressing the Reset button Sharp objects can cause damage use a flat object such as a paper clip 28 Mellanox Technologies 324 Port InfiniBand QDR Switch Platform Hardware User Manual Rev 1 8 Figure 14 Reset Button CONSOLE MGT a RST PSU S FANS L FANS MASTER h Mh This button resets the CPU of the management module A quick push of this button performs this reset When the reset button is pushed on the master management module this management mod ule is reset becoming the slave and the other management module becomes the master If there is only one management module in the chassis all of the leafs and ports are reset by bringing them down and powering them up when the reset button is push
77. supports must be between 65 and 80 cm Mellanox Technologies 33 Rev 1 8 Installation Figure 15 Distance Between the Vertical Supports This edge of the shelf must be as close as possible to the inside of the door when closed 3 5 2 ESD Connection Before starting any procedure on the 5300 series Switch system 1 Put an ESD prevention wrist strap on your wrist and make sure there is good contact between your body and the strap 2 Plug the other end of the wrist strap to a valid ground Make sure that this is a tight fit 3 5 3 Installation Procedure Installing the chassis will be a lot easier if you can remove the sides of the rack LA You will need a fork lift to move and insert the chassis into the rack 3 5 3 1 Requirements You will need e 2 phillips screwdriver e 3 phillips screwdriver e a fork lift e a grounding lug e measuring tape e ground wire of sufficient length and gauge to properly ground the chassis 34 Mellanox Technologies 324 Port InfiniBand QDR Switch Platform Hardware User Manual Rev 1 8 e Parts included in the installation kit 1 shelf with brackets pre installed 1 left side upper bracket offset 2 lock down bars 8 lock washers for the upper brackets to vertical support 10 hex head bolts 8 for the upper brackets and 2 for the shelf extension 20 pan head screws for the caged nuts 12 for the shelf and 8 for the chassis faceplate 32 lock washers 20 for
78. toring of AC power to the PSUs DC power out from the PSUs chassis failures e querying for switch serial numbers 72 Mellanox Technologies 324 Port InfiniBand QDR Switch Platform Hardware User Manual Rev 1 8 revisions software version SwitchX FW version switch temperatures The manager also has the ability to burn new firmware and upgrade software on the switch 7 1 InfiniBand Subnet Manager The InfiniBand Subnet Manager SM is a centralized entity running in the switch It discovers and configures all the InfiniBand fabric devices to enable traffic flow between those devices The SM applies network traffic related configurations such as QoS routing partitioning to the fabric devices You can view and configure the Subnet Parameters SM via the CLI WebUI Each InfiniBand subnet needs one subnet manager to discover activate and manage the subnet An InfiniBand network requires a Subnet Manager to be running in either the Infiniband switch itself switch based or on one of the nodes which is connected to the Infiniband fabric host based The Subnet management features include In addition the tools enable firmware management capabilities such as e upgrading drivers e upgrading software e monitoring of AC power to the PSUs DC power out from the PSUs board temperature fan module unit failure in the switch system system failure in the switch system e querying for board serial nu
79. washer Upper bracket offset OH 69 E L Hl Lack washers Caged nuts Phillips pan head hex head bolt Flat head screw screw Flat washers 3 5 3 2 Opening the Container 1 Before starting the procedure put the ESD strap on and connect it to a valid ground 2 Remove the four sides of the container by unscrewing the phillips head screws holding the sides on 36 Mellanox Technologies 324 Port InfiniBand QDR Switch Platform Hardware User Manual Rev 1 8 Figure 17 Container Screws Qe a IN CAN Container screws Remove and put aside the box containing the cables Remove and put aside the box containing the cable management kit Remove and put aside the box containing the Installation kit Ne Visually inspect the chassis make sure that there is no visible damage all 12 spines are installed 6 PSUs are installed all 4 fans are installed management module is installed 7 Remove all protective plastic film from all sides and top of the chassis a The leafs are shipped separately A second redundant management module when ordered is shipped separately gt Mellanox Technologies 37 Rev 1 8 Installation LA Do not remove any of the blocks or either of the lock down bars at this time 3 5 3 3 Installing the Shelf of the pallet Should the chassis start to f
80. zone avec une temp rature ambiante d passant le maximum recommand de 45 C 113 F Un flux d air de 200LFM cette temp rature ambiante maximale est n cessaire En outre pour garantir un bon coulement de l air laissez au moins 8 cm 3 pouces d espace libre autour des ouver tures de ventilation 3 Empilage du ch ssis Le ch ssis ne doit pas tre empil sur un autre mat riel Si le ch ssis tombe il peut pro voquer des blessures corporelles et des d gradations de biens gt 4 Connection d Alimentation electrique excedentaire dangers lectriques Ce produit comporte un couvercle transparent sur l espace pour l alimentation lec trique redondante Ne pas faire fonctionner le produit si le couvercle transparent n est pas solidement fix ou s il est enlev gt 5 Orages dangers lectriques Pendant un orage il ne faut pas utiliser le mat riel et il ne faut pas brancher ou d brancher les cables gt 6 Branchement d branchement des cables InfiniBand en cuivre Les cables InfiniBand en cuivre sont lourds et ne sont pas flexibles il faut donc faire tr s attention en les branchant et en les d branchant des connecteurs Consultez le fab ricant des cables pour connaitre les mises en garde et les instructions sp ciales gt 7 Montage et entretien sur baie Lorsque ce produit est mont ou entretenu sur baie il faut prendre des pr cautions sp ciales pour s assurer

Download Pdf Manuals

image

Related Search

Related Contents

Octopus ABS - scubaspares  to the User Manual for the FS-01 safe  HP 5000 Stampante a fogli separati D640 Manuale dell`utente  un retour Des norMes roMAnesques DAns lA littérAture  Guia de usuario, de configuracion y de instalacion del software de  Cisco Systems 2955 Switch User Manual  Samsung SGH-M300 Brugervejledning  automatisme d1000  Manuel de l`opérateur  取扱説明書 N706iⅡ  

Copyright © All rights reserved.
Failed to retrieve file