Home

Integrated Access Controller

image

Contents

1. CCTV amp Security Distributor Integrated Access Controller CE FC GA 7 Instruction for Keypad Function 7 1 1 Model and Appearance A AC 930P 1 1 Structure and Appearance design of Provisual AC 930P are patented and any sort form of copy and counterfeit will be charged 1 2 Color pure black black decorated with silver 1 3 Size LxWxH mm 150x88x30 2 Important Notices Failure to follow the instructions below may lead to the malfunction of the system property damage and even physical injury 2 1 Connection and operation on any components or the controller with power on is strictly prohibited 2 2 Connect the system according to the instructions described in this manual 2 3 The RS232 cable connected to the computer should be no more than 15 meters 2 4 The RS485 cable connected to the computer should be no more than 1200m 2 5 Please use the specified power supply 2 6 The communication mode between the controller and computer should be either RS232 or RS485 JE F JP Ja 2 7 When RS485 mode is applied a highway Wa EAN y O REAN JP1 can connect maximally 32 controllers with identification address differs from each other Provisual 14 20 2007 04 16 Sound Indication Device sounds once is keypad input device sounds twice continuously means error or exit Accessin
2. 4 4 3 Open the back cover and connect the device according to the wiring diagram 7 3 2 7 3 3 Installation Instruction 7 a a 4 1 Remove the two keys first 4 2 Unfasten the two screws push up the back cover to open First open the lower part of backcover for around 1cm Please note that open too wide may lead to damage to the device A 4 4 Fix the backcover on the wall and reassemble the device according to 4 1 4 2 and 4 3 in reversed order Door open Mode This function is used to define the mode of door open including three modes card card password and password For card password and password mode the door open password and card holder password are the same Open by Card Select 2 1 Only Card Select i 1 Open Delay 2 Card amp PSW V 2 Open Mode vY Door will be opened once the card is valid Open by Card and Password Select 2 1 Only Card 1 Open Delay 2 O0pen Mode v 1 Open Delay 2 O0pen Mode w 2 Card amp PSW V 2 0pen Mode w Select 2 l 1 Open Delay OUN Vy Door will be opened once the card is valid and card holder password is correctly inputted Screen Password 1 Door open Delay 3 Screen PSW A
3. 7 5 2 Modify card holder password Card holder password can be applied in both the password and the card password door open mode In the Screen door open password mode password only is ineffective for opening door the initial value is empty 4 Password manage 3 Employee A select 4 SSS 1 Change Admi PWD modified 2 Change User PWD 1 Change Admi PWD select 2 Input new PSW 2 Change User PWD l input password input an Input again
4. 2 Door open Mode Y 4 Open PSW Select 3 1 Open Delay 2 Open Mode Y Input door open password card holder password can not open the door Activate Password Select 4 1 Open Delay 2 Open Mode v 1 Door open Delay j L Ea PSW A gt 2 Door open Mode Y 4 Open PSW Door can be opened by password Information Release Information release refers to use the LCD of integrated access controller to display some information such as meeting information overtime information and so on Management software can be used to enter the information publish settings tools gt LCD display design As shown below c Provisunl Acces Attendance Syxtem V1 2 1 20001 5 Communication Mode Setup Change the communication mode with computer by changing the jumper wire in jumper JP1 Ey ano Ldf N A Oo N 8 N nnn aes 485 232 aNd Xy XL oooooo0o0000000000 GE ane 485 232 485 232 RS485 Mode RS232 Mode 6 Rules for Installation 6 1 Selection of exterior components may be based on installation environment However the selection should be in accordance to existing National and International Standards as well as matched with the controller A careful study on the instructions on exterior components selecti
5. Input number J input umber has been deleted Delete all cards Delete all cards will render all cards set by keyboard into illegal cards system initiation will clear all cards and should be applied carefully select 2 Are deleting J rarno for 4 s 2 Delete card 2 Delete All Card 1 Add card select 2 1 Delete card waiting for 1 s 1 Delete card 2 Delete All Card EEEN 1 Add card 2 Delete card select 2 1 Delete card a 2 Delete All Card 1 Delete card 2 Delete All Card A y 7 5 Password management Password management refers to the management of administrator password and card holder password Administrator password is used to enter Edit status Card holder password is used to open the door in the password or card password door open mode they are the same one 7 5 1 Modify administrator password Default administrator password is 000000 if two inputs are inconsistent the device will automatically return to the higher lever menu 1 Change Admi PWD 2 Change User PWD select 4 3 Employee Manage 4 Password manage FA input password L H Input again 1 Change Admi PWD select Input new PSW 2 Change User PWD input password
6. anti disassemble setup time adjustment Input administrator password and enter lever 1 menu of edit 1 Basic Setup 2 Pass Mode VY Push 1 to enter basic setup as following 1 System Initate 2 Address Setup V 7 2 1 System Initiation System initiation will clear all original setup of the controller including pass mode setup basic setup all Keypad added card password etc however administrator setup will not be changed Wale tOr 2e 1 System Initate 2 Address Setup V 5 Select 1 aes jot When initiation finished the device returns to last screen System initiation will clear all original setup of the controller and should be applied carefully 7 2 2 Address Setup Address is applied to differentiate the controller from any other devices on the network An address within a single 485 network should be unique Address ranges from 00 to 39 3 Product Parameters 3 1 3 2 3 3 3 4 3 5 3 6 Electric Parameters Working Voltage DC9 15V Anti static Capability 215KV Static Current lt 110mA Relative Humidity 0 95 Input Interface Stem joint switch input Working Temperature 10 Cto 55 C Drive Capability 2 groups of Type C Relay output DC12V 3A Power off Protection Data will be preserved for 10 years when power off Type of Card EM card or compatible EM Card I O Interface 2 groups of switch input 1 group a
7. g the Menu Press then LCD displays English and Chinese select the language 1 Chinese 2 English Press 1 or 2 to select the type of language Keypad Edit Input password or password card and wait for 6 seconds Enter Edit Mode Input the 6 digit administrator password default password is 000000 Admin Password ok 2k 2k ok 2K ok The device enters Edit if password is correct otherwise device sounds twice and returns to last screen if password is wrong 1 Basic Setup 2 Pass Mode VY VA shows there are other pages to be shown you can use key 6 and key 9 for moving the page 6 for page up and 9 for page down Once device enters edit menu the user can setup the controller Push to return to upper level menu For setup hierarchy please note the following Employee Password Basi t asic Setup Pass Mode Manage Manage n gt gt gt 5 gt g O J lt E E B ey kel G a D ao ao o o D o a D So foes D oO n fol 5 5 O ORS O 3 on ai J D oO e s 5 a rt D o U2 Wa 3 o a D vo ovo 3 nN oO Y Q Si niot NO 2 oO D y 2 a Ny 3 25 om ia z 2 2282 gt o an gQ D o gt D O a Pe 5 a al D a Q e lt oO 5 a 1 Oo D D z o ETLE al 2 oy a U re A Q a a 2 O a D 2 A 5 8 a fal ee al O D B S a a 2 a 7 2 Basic Setup Basic setup includes system initiation address setup
8. installation procedure Refer to Installation amp Commissioning Manual Strictly follow the diagram for connection TN DS O T N ce T OQO OOGO OOT OO TOOTO OOOO Q Controller Power X Access Controller S GND RX S aceo 2a0v MQ12V 485232 TX DATO GND S3 IDAT1 485 a Sw 485 O AS O IGND 2C 87 Gp MenC1 2NOK3 IGND 1NOIG gt BELL 1C gB AC 90 220V Q BELL INC ERT Fail Secure a S GND O 12V olf Ne 4 Door of n WE Te Magnet Ve aE pe Tee 5 1S sain KA Exit Button Doorbell eel Any modification will be notified Exterior Reader aiad Input start number Prout number read card please read card push to exit when finish 1 Add card 2 Delete card select 1 Add_ Multi_card gt E 1 Add_Multi_card 2 Add_Single_card Add single card User can define a certain number to a card only one card can be defined in one time If the number had been defined to other card before the new defined card will overwrite the original card selectl n select 2 Je a Pe eee e J inoutcode Se e 7 4 2 Delete card Delete card includes delete single card and delete all cards 2 Delete card 1 Add card Delete single card Specify code and delete One time one card can be deleted
9. nti disassemble alarm input 1 exterior card interface 2 groups of output interfaces DC12 3A Network Interface RS232 RS485 interface Communication Rate 9600bps Display Mode 2X18 LCD display Language English Chinese System Capacity and Main Functions Number of Card Holder 3000 Number of Records 8200 pcs Entrance Exit Mode Card alone Card plus Password Password alone nitial Card Open Multiple Card Open 2 lt N lt 4 Remote Open Forced Open Multiple and programmable working modes Normal Open Forced Close ldentification after Card presenting Door will be opened only after the card holder is identified by the control center Anti passback function Multiple access group and working hour setup Every controller supports 42 access groups Support 20 groups of schedule Support 32 groups of annual holiday setup Protection All inputs are equipped with imported TVS protection Voltage clamp protection All outputs adopt spark depress circuit and absorption circuit Input 2 digit 2 Address Setup V New Address 2 Address Setup V l 1 System Initate Old Address 00 e 1 System Initate lt Initiation address is 00 input the new address and return The device sounds twice and returns in case of wrong input 7 2 3 Time Adjustment Time adjustment is to synchronize
10. on is strongly advised 6 2 Installation of the control unit including microprocessor should not be inside the high voltage box or near any large converter or high voltage current devices The components should be installed in places easy for uninstallation in order for convenient maintenance 6 3 The controller board should be connected to earth independently Please ensure that grounding has been provided in the installation site 6 4 When installing the box with microprocessors inside please ensure that the screw and lock has been fastened 6 5 The 220V terminal power cable should be plugged in separate power supply socket the power cable should not share the socket with other devices with grounding ensured 6 6 Do not crossover the system cables through other devices 6 7 All components should not be installed in places with excess high low temperature or humidity Download the message to device after inputting the message in software This function is applied to AC 930P only There can be max 9 Chinese characters and 18 English letters for each row 15 00 meeting today staff training tomorrow result shown Delete information release setup as following enter 9 to next page 1 Open Delay l 3 Info Distribute a seleni b Cancel 00 2 Open Mode w Enter 00 to delete setup and return to the default setup Information can also be deleted from sof
11. time of controller with real time The time can also be setup off line Only 2 digit of year can be inputted week format 01 07 Push 9 for 1 System Initate page down 3 Adjust Time a Select 3 l 2 Address Setup V 4 Anti disassemble 1 System Initate a Week 2 Address Setup V YY MM DD HH MM J irputtime Week 7 2 4 Anti disassemble Alarm Anti disassemble alarm is applied to protect controller from being disassembled or damaged PE 1 System Initate a 3 Adjust Time et i gt A ON 00 2 Address Setup V 4 Anti disassemble OFF 01 l 1 System Initate 2 Address Setup V 7 3 Pass Mode This function is used to define the mode of pass Door open delay and information distribution There are three modes card card password and password For card password and password mode the door open password and cardholder password are the same 1 Basic Setup 2 PassMode V d Select 2 to enter Pass Mode 1 Open Delay 2 Open Mode wY 7 3 1 Door open Delay Door open delay is the duration from the time door is opened to the time the door automatically closes Duration ranges from 00 99m seconds 1 Open Delay Select 1 22S Input du 1 Open Delay 2 Open Mode w 2 Open Mode w
12. tware 7 4 Employee management This function enables the user to add or delete card holders by the integrated access controller without connecting to computer Max 1500 cards card holders can be managed in off line manage mode There is no conflict between off line cards and cards read by computer The off line card possesses top authority and is not affected by such functions as multiple card initial card remote control anti passback and access level 1 Basic setup 2 Pass mode w Page down by number 9 3 Employee Managea 4 Password Manage Enter 3 to employee management 1 Add card 2 Delete card 7 4 1 Add card Add card includes add multiple cards and add single card Add multiple cards A number of cards can be registered in the device with a defined number The second card will be assigned with a number next to the number defined to the Controller Wiring Diagram Computer Interface DB9 Hole aaa sal E LEen bl g H1S el RS485 RS232 of amp ame ID Convertor ole E r56 Op EO Alarm Light AC 322MA O Detailed

Download Pdf Manuals

image

Related Search

Related Contents

Video 75 Plus EFP_Version 2_9_02_12.qxp    Samsung SCH-B379/S คู่มือการใช้งาน    快聴 S20 取扱説明書  F107d INSTRUCTION MANUAL  N150 WiFi Router (N150R) Installation Guide  Radica Games Snowboarder 76044 User's Manual  Manual de usuario  Sony Xperia ion 16GB Black  

Copyright © All rights reserved.
Failed to retrieve file