Instruction Manual

image

Contents

1. Tel 91 11 25225225 25229206 42464264 Fax 91 11 25225062 E mail sales anandind com Works 1460 M I E Bahadurgarh Haryana 124507 India EC REP KALEIDOS SH VIA PONTIOA 4 2012 MILANO ITALY WwWww anandind e com Page 5 DOC ID NO 6103 REV 01 DATE 09 10 2010 www suction india com
2. 2 Ltr PC Jar instructions provided by the suppliers of cleaning agents as well as by the manufacturers of sterilization or disinfection units must also be followed where application temperature process duration and airing etc are concerned wWwww anandind e com Page 2 DOC ID NO 6103 REV 01 DATE 09 10 2010 WwWww suction indtia com l Anand MEDICAIDS Instruction Cum User Manual PRIVATE LIMITED For EVROVAC B BACTERIAL FILTER The replaceable filter element filters evacuated air before it enters the pump thereby infecting the environment It must be changed on normal days but immediately after vapours have entered or after infective suction has been done PUMP The unit is fitted with Piston type oil free pump provides reduced maintenance cost a Open the unit with the aid of an allen key provided and disconnect the tube from the inlet point on the pump housing b Take out the motorized pump fitted on and together with the platform c The fly valves sheet is placed in the top the four screws of which can be opened one for vacuum and the other for outlet The piston is fitted below the top and over the eccentrically rotated came Just wipe clean these parts and set the unit again d There are two openings small and U type large in both the top portions While fitting see that large U of the one face towards the small round of the other and small of the first face the large of the screws can be put back
3. No Leaks at tube ends Push in as far as stop Motor does Not Run Bacteria filter housing on Safety jar top Filter paper Condition position of housing BATTERY Charge the unit for 4 6 hours or replace battery Inadequate Suction Performance Inadequate battery back up Blockage or kink in tubing within the Isolate source of trouble as follows connection open If the vacuum gauge now indicates zero vacuum the cause is external External cause Bacteria filter safety jar overflow valve in the Investigate the whole external suction circuit lid float valve push in connectors tubing etc for blockage s float valve sticking kinked tubing and rectify If the vacuum gauge still indicates a vacuum Pump does not suck however the cause is internal gt gt U gt N e9 O Cc 09 O gt O gt gt U gt www anandind com Page 4 DOC ID NO 6103 REV 01 DATE 09 10 2010 www suction india com Anand MEDICAIDS Instruction Cum User Manual PRIVATE LIMITED For EUROVAC B TERMS OF WARRANTY Anand Medicaids Private Limited warranty the high quality and workmanship of each Anand s HI VAC for a period of one year subsequent to the date of delivery by the company During this period faulty material will be replaced free of charge This warranty does not extend to components that are subject to wear and tear in the course of normal operatio
4. An ISO 9001 2008 13485 2012 Certified Company Anand MEDICAIDS Instruction Cum User Manual PRIVATE LIMITED For EVUROVAC B CE 2195 Vacuum Gauge Vacuum Control Knob Connector for Power Supply Patient use On Off Switch Push in Nozzle Cut off Valve Main Lead Connector i E Wem gt 2 Itr Jar oe ABS Enclosure Bacterial Filter Safety Jar Jar Back Side Dear Customer Congratulations on your purchase of this versatile and need oriented suction unit It will serve you well for years if properly looked after It is designed for use in ambulances hospitals nursing homes ICU and for home care Non corrosive and shockproof enclosure is pressure moulded in engineering plastic ABS giving smooth and easy to clean surface ASSEMBLY The pump based on piston system batteries and PC card are housed in enclosure The panel has a vacuum gauge release valve for vacuum adjustment push to on push to off switch and four neon lights indicating external power mains AC on internal battery vehicle battery 4 internal battery charging level 1 2 3 The first is for AC mains second for internal battery pack third for vehicle battery and the last shows battery charging level An ON OFF switch on the panel is for switching the unit push to on push to off Vehicle charging cord when required is to be connected on socket with threading provided on side Www anandin
5. T be removed by rotating anticlockwise with the aid of a simple hand tool Antibacterial filter element replaceable is slipped into the safety jar at the back and the other end is connected to the slot marked Vacuum on the jar lid The second nozzle is marked patient and the tubing from this goes to the patient The release valve for adjusting the negative pressure and the vacuum gauge are on the panel Main on off switch cum pilot lamp fuse and the removable main lead connector are on the side Before the unit is put on please see that 1 O rings on the push in connector are not worn out Check that safety jar with 2 O rings is well inserted 2 Jar be checked for any crack tubing and lid be tightly placed on the jar The angular connector must be inserted as far as the stop While unplugging twist and pull 3 Adjust vacuum before use Fully tightened clockwise knob means full vacuum JAR CLEANING AND DISINFECTING Polycarbonate jar PC is superior to glass 3 4th filling is recommended After each use jar lid over flow cut off valve catheters etc should be cleaned thoroughly When cleaning is necessary after infective fluid has been evacuated d the jar lid filter housing tube cut off valve can be sterilized by autoclaving up amp to 120 C for 20 minutes Ep Alkaline cleaning agents and disinfectants based on phenyl may not be used Adherence to hospital directives on hygiene is of prime importance The
6. and tightened in their positions e Please run the unit and see its satisfactory functioning before housing is screwed up Unlike the rotary design NO LUBRICATION IS REQUIRED IN THIS PUMP The unit has not to be tampered with by any mechanic other than our factory engineer or the person authorized Bacterial Filter Pump Exhaust Outlet y DC Motor BATTERY CHARGING REPLACEMENT If the unit remains unused for say ten days it should be connected to the AC supply and switched on for over two hours For battery replacement Open the back of the unit remove negative and positive connectors on the battery Remove the battery form the hook and install new battery Remember to charge the new battery for 8 10 hours for optimum performance Patient Filter Gauge To Sensor sad ney Vehicle ee ee Charging ar Cord PC CARD Inlet Outlet MOTORIZED PUMP www anandind com Page 3 DOCIO NG e10 REV 01 DATE 09 10 2010 www suction india com i Anand MEDICAIDS Instruction Cum User Manual PRIVATE LIMITED For EUROVAC B TROUBLE SHOOTING Possible source of trouble Check Action to be taken Power Supply Voltage power socket Set at ON Electrical cord Plug type plug connections damaged cord Leak within the pump or in the external Isolate the source of trouble by carrying out suction circuit the checks outlined External cause Push in connector O rings Lid gasket Condition Push in angular connectors
7. d ecom Page 1 DOC ID NO 6103 REV 01 DATE 09 10 2010 www suction india com Anand MEDICAIDS Instruction Cum User Manual PRIVATE LIMITED For EUROVAC B TECHNICAL Housing Robust engineering moulded shock resistant ABS plastic Capacity 575mm Hg 10 Vacuum 14 Itrs min Pump Type Oil free piston pump Jars Wide mouthed autoclavable 2ltr Collection jar Polycarbonate safety jar withmechanical electronic overflow motor shut off system and overflow bacterial filter Tubing 8 mm ID x 2 mtr Silicon Vacuum Gauge 6 25 cms 0 760mm Hg calibration Power Operates on 220 V AC and 12 VDC internal battery 7 2 Ah 110V on request Dimension amp Weight 20 x 42 x 36cms 9 kg Battery Backup 120 minutes on full charge In built maintenance free battery Provided with cable for AC mains and ambulance car use VACUUM AT ALTITUDES The specified maximum vacuum refers to sea level According to local conditions and barometric pressure slight deviations in vacuum reading may be noted As a reference the table below shows several factors by which the indicated maximum vacuum value must be multiplied according to the altitude of location where the measurement is carried out Location Maximum Vacuum Location Sea level 100m 2000m 4000m Factor 1 00 0 88 0 78 0 60 The pump is housed in the enclosure To fasten it well with the base two hexa head bolts used as holdfast for transportation at the bottom of the unit MUS
8. n or due to improper treatment maintenance as per instructions Further conditions in accordance with international standard IEC 601 1 item 6 8 2b The manufacturer is only responsible for effects on the safety the reliability and the performance of the appliance if e Installation additions adjustments modifications or repairs are carried out by personnel authorized by the manufacturer e The electrical installations within the room concerned satisfy the requirements laid down by IEC e The appliance is used in full accordance with the instruction manual which is solely a guide and no substitute for professional training The safe and effective use of this product largely depends on the skill of the operator We are not liable for any damages due to mishandling or improper and unauthorised use e The company reserve the right to change technical specifications designations and catalogue numbers without prior notice Note Ensure that your electrical wirings are well earthed with 1 line and 1 neutral phase and your voltage is between 220V 240V 50 Hz Ensure that the suction unit should not be lifted above human body level Dispose of used product packaging in safe manner so as not to harm stray cattle children and environment WARRANTY CARD Model No ____LL eee Lee LLL LLL INN eee eee Date of Purchase Dealer Name taal ANAND MEDICAIDS PRIVATE LIMITED Regd Office 33 16 Punjabi Bagh Extn New Delhi 110026 India