Home
IP to RS-232
Contents
1. 2 Basic Operation IP GONTIQUIALION RE EE N EE EE 8 Using Synek SLAE ER EE EE EE N 8 RS 232 Inierla6e sir EE EES E eve We ee ee ee 10 RS 232 IMEMA CE sesse EA Re nk Nee cave ER oe gese ese BA Ee ek eN He Dee 10 RS 232 Setlings testen iu Re Ee eN Ge EN Re ER EG ge vi 10 Web Interface 3 Advanced Operation eer ne OE EE RE NE 28 4 Appendix viii This page left intentionally blank This page left intentionally blank IP to RS 232 Converter te Getting Started Iatedele dle dels 1 page 2 ie v 25 72 Da gt v Name IP Reset RS 232 1 Power 5V DC IP control RS 232 2 Introduction Description Resets the unit to its default IP settings Connect an RS 232 cable from this port to an RS 232 device See Installation page 4 for more information This LED will glow bright blue when the unit is powered Connect the included 5V DC power supply to this power receptacle Connect an Ethernet cable between this jack and an IP based automation control device Connect an RS 232 cable from this port to an RS 232 device See Installation page 4 for more information page 3 Getting Started Installation Connection Instructions 1 Connect an Ethernet cable between the IP based control device and the IP control port on the IP to 2 x RS 232 Converter An Ethernet switch can also exist between the IP to 2 x RS 232 Converter and the IP b
2. Maximum length 8 characters Terminal Port Type the Telnet listening port in this field Range 1 1024 page 21 Basic Operation UDP Settings Enable UDP Access UDP Port Enable UDP Echo v Destination UDP IP Address 192 168 1 129 Destination UDP Port 50008 Discovery Protocol Settings Enable Discovery Web Interface Enable UDP Access Enables or disables UDP access Options Enable checked Disable unckecked UDP Port Sets the UDP port Range 1 1024 Enable UDP Echo Enables or disables UDP echo Options Enable checked Disable unckecked page 22 S ie L a ie 4 faal Web Interface UDP Settings Enable UDP Access UDP Port Enable UDP Echo v Destination UDP IP Address 192 168 1 129 Destination UDP Port 50008 Discovery Protocol Settings Enable Discovery 7 sanken se Destination UDP IP Address Enter the remote UDP IP address in this field Range per byte 0 255 Destination UDP Port Type the remote UDP port in this field Range 1 1024 Enable Discovery Enables or disables discovery mode This feature must be enabled in order for the Gefen Discovery Tool to detect the unit on a network Options Enable checked Disable unckecked page 23 Web Interface System tab Download Current Configuration Basic Operation Restore Configuration Browse
3. Restore Warning All current settings will be lost Gefen IP To RS 232 Bridge EXT IP 2 RS2322 2 Download Download Current Configuration Saves the current configuration of the IP to 2 x RS 232 Converter to a file Browse Restore Configuration Selects the configuration file to load See the Download button above Restore Click this button to upload the selected configuration file to the IP to 2 x RS 232 Converter page 24 Basic Operation Firmware Update UI ver 1 44 Browse Factory Reset Select Settings for reset F Select All Network RS 232 Reboot Browse Firmware Update Click this button to select the firmware file to be uploaded Update Click this button to upload the selected firmware file See the Browse button above Factory Reset Use these check boxes to select the type of factory reset to perform Placing a check mark in the desired check box will select the type of reset Options Select All resets network and RS 232 settings Network resets IP settings only RS 232 resets RS 232 settings only Reset Click this button to reset the selected options to factory default settings Reboot Click this button to reboot the IP to 2 x RS 232 Converter page 25 Web Interface This page left intentionally blank IP to RS 232 Converter us Advanced Operation Advanced Operation Commands set add del
4. Commands show_serial params Displays the current settings of the specified serial port Syntax Advanced Operation show_serial params paraml Parameters param Port so Example show serial params 1 Serial port 1 parameters Word length 8 bits Stop bits 1 bit Parity None Baud Rate 19200 Bps Line Delay 1000 ms Related Commands set_serial params page 61 Commands show_telnet pass Displays the current TCP terminal password Syntax show telnet pass Advanced Operation Parameters None Example show telnet pass TCP Terminal password b055man Related Commands set_telnet_pass page 62 Advanced Operation show ve r data Displays the current software and hardware version Syntax show ver data Parameters None Example show ver data Firmware version 1 48 Release date May 12 2014 Release time 14 09 37 page 63 Commands Commands system wide reset Restarts the IP to 2 x RS 232 Converter according to the supplied parameter Syntax Advanced Operation system wide reset paraml Parameters param1 Value 0 3 0 Reboot only 1 Reset IP settings 2 Reset serial port settings 3 Reset all and reboot Example system wide_reset 3 System wide reset in progress Please wait Finish selected operation Device will be reset and all connections will be closed page 64 Advanced Operation
5. 2 IP 192 168 1 181 Port UDP Remote Bridge 2 Echo Disabled Discovery Mode Enabled Related Commands set_gateway set_http_port set_ipadd set_netmask t set tcp br port t set tcp term port set_udp br port set udp echo br set_udp port set_udp remote br set_udp rip set_udp_rport page 57 Se IP to 2 x RS 232 Converter settings Commands 50000 50001 use discovery use tcp access tuse tcp term pass use udp access use_udp echo Advanced Operation Commands show_me Enables or disables the flashing of the LED on the device When enabled the LED indicator will flash red and blue The default setting is disabled Syntax show_me paraml Parameters param1 State Disabled Enabled Example show_me 1 Show me is Enabled Related Commands use discovery page 58 Advanced Operation Commands show_serial descr Displays the description of the specified serial port Syntax show_serial descr paraml Parameters param1 Port sd Example show serial descr 1 Serial port 1 Description DVD Ctrl Related Commands tfset serial descr page 59 Advanced Operation Commands show serial mode Displays the mode of the specified serial port Syntax show serial mode paraml Parameters param1 Port so Example show serial mode 1 Serial port 1 working mode is TCP Bridge Mode Related Commands tset serial mode page 60
6. Commands use discovery Enables or disables discovery access mode If this mode is disabled then the IP to 2 x RS 232 Converter will not be discoverable when using the Gefen Discovery Tool The default setting is enabled Syntax use discovery paraml Parameters paraml State Discovery access disabled Discovery access enabled Example use discovery 1 Discovery Access is set to Enabled Related Commands show me page 65 Commands use tcp access Enables or disables TCP access mode This mode must be enabled before using RS 232 command to configure the IP to 2 x RS 232 Converter Syntax Advanced Operation use_tcp access paraml Parameters param1 Value 0 Disable TCP access Enable TCP access Example use_tcp access 1 TCP Access is set to Enabled Related Commands t set tcp br port t set tcp term port set telnet pass use tcp term pass page 66 Commands use tcp term pass Enables or disables the use of the password during terminal sessions Syntax Advanced Operation use tcp term pass paraml Parameters param1 Value 0 1 Do not use password Require password Example use_tcp_term pass 1 TCP Terminal password at login is set to ON Related Commands set_tcp_br port set_tcp_term port set_telnet_pass use discovery page 67 Commands use udp access Enables or disables UDP access Syntax use_udp access paraml Adva
7. I GEFEN IP to RS 232 Converter EX P 2 RS52322 User Manual Important Safety Instruetions 10 11 12 13 14 15 Read these instructions Keep these instructions Heed all warnings Follow all instructions Do not use this product near water Clean only with a dry cloth Do not block any ventilation openings Install in accordance with the manufacturer s instructions Do not install or place this product near any heat sources such as radiators heat registers stoves or other apparatus including amplifiers that produce heat Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong are provided for your safety Ifthe provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus Only use attachments accessories specified by the manufacturer To reduce the risk of electric shock and or damage to this product never handle or touch this unit or power cord if your hands are wet or damp Do not expose this product to rain or moisture Unplug this apparatus during lightning storms or when unused for long pe
8. is connected Range per byte 0 255 HTTP Port Select the network mode from the drop down list Range per byte 1 1024 page 19 Web Interface TCP Telnet Settings Enable TCP Access v Require Password on Connect 7 User Name Admin Old Password New Password Basic Operation Confirm New Password Terminal Port Enable TCP Access Enables or disables TCP access Options Enable checked Disable unckecked Require Password on Connect Forces password prompt for Telnet sessions Options Enable checked Disable unckecked User Name Displays the user name for TCP sessions The user name cannot be changed Old Password Type the current old password in this field The password is automatically masked when entered The password is case sensitive The default password is Admin Maximum length 8 characters page 20 S L ok e Ty faal Web Interface TCP Telnet Settings Enable TCP Access Fi Require Password on Connect 7 User Name Admin Old Password New Password Confirm New Password Terminal Port New Password Type the new password in this field The password is automatically masked when entered The password is case sensitive Maximum length 8 characters Confirm Password Re type the new password in this field The password must match the same password that was entered in the New Password field
9. mode param3 Start delimiter 00 FF Example set_start_del 1 1 a0 Start delimiter set to ON with a value of a0 Related Commands set_add delim set_end_del page 45 Advanced Operation Commands set_tcp br port Sets the TCP bridge listening port for the specified serial port The default port settings for RS 232 1 and RS 232 2 ports are 49200 and 49201 respectively Syntax set tcp br port paraml param2 Parameters param Serial port 1 2 param2 TCP port 1 65535 Example set_tcp_br port 1 49200 TCP Bridge 1 port set to 49200 Related Commands set_tcp_term_ port set_udp br port page 46 Advanced Operation Commands set_tcp term port Sets the TCP terminal listening port The default port settings is 23 Syntax set_tcp_term port paraml Parameters param TCP port 1 65535 Example set_tcp_term port 23 New TCP Terminal port set to 23 Related Commands set_tcp_br_ port set_udp_br_ port page 47 Advanced Operation Commands set telnet pass Sets the TCP Terminal password The password cannot exceed 20 characters in length param3 is used to verify the new password The default password is Admin Syntax set_telnet_pass paraml param2 param3 Parameters param Old password 20 chars max param2 New password 20 chars max param3 New password 20 chars max Example set_telnet_pass Admin b055man b055man TCP Terminal passw
10. port param2 must be entered in dot decimal notation Syntax set_udp_remote br paraml param2 param3 Parameters param Serial port 1 2 param2 Address param3 Remote port 1 65535 Example set_udp_remote br 1 192 168 1 70 51000 Remote UDP bridge 1 set to IP 192 168 1 70 Port 51000 Related Commands set_udp_ port set_udp_br_ port set_udp_echo_br set udp rip set_udp_rport page 52 Advanced Operation Commands set_udp rip Sets the remote UDP IP address The IP address must be entered using dot decimal notation Each digit can range between 0 and 255 Syntax set_udp_rip paraml Parameters param IP address Example set_udp_ rip 192 168 1 205 New Remote UDP IP set to 192 168 1 205 Related Commands set_udp br port set udp echo br set_udp_remote_br set udp echo br page 53 Commands set udp rport Sets the remote UDP listening port The default port settings is 50008 Syntax Advanced Operation set_udp_rport paraml Parameters param1 Port 1 65535 Example set_udp_rport 50006 New UDP Remote port set to 50006 Related Commands set_udp br port set udp echo br set_udp remote br set udp rip page 54 Commands show del prms Displays the current delimiter parameters for the specified serial port Syntax Advanced Operation show del prms paraml Parameters param1 Port so Example show del prms 1 Delimit
11. Destination IP 192 168 1 180 Destination Port 50000 UDP Echo Enable S AI ie ha od wn faal Destination IP Enter the destination where the data will be sent IP address in this field Range per byte 0 255 Destination Port Enter the destination port in this field Range 1024 65535 UDP Echo Useful in troubleshooting and measuring response times and end to end connectivity Options Enable checked Disable unchecked Set Defaults Click this button to reset RS 232 settings to their default values Save Click this button to save any changes page 17 Web Interface Network tab IP Settings MAC Address 00 1C 91 02 20 03 Mode Static IP Address 192 168 1 72 Subnet 255 255 255 0 Gateway 192 168 1 254 HTTP Port Basic Operation MAC Address The MAC address of the IP to RS 232 Converter The MAC address cannot be changed Mode Select the network mode from the drop down list Options Static DHCP IP Address Enter the IP address of the IP to 2 x RS 232 Converter Range per byte 0 255 Subnet Enter the subnet mask of the IP to 2 x RS 232 Converter Range per byte 0 255 page 18 Web Interface IP Settings o MAC Address 00 1C 91 02 20 03 2 Mode Static IP Address 192 168 1 72 Subnet 255 255 255 0 Gateway 192 168 1 254 HTTP Port 80 Gateway The gateway router IP address to with the IP to 2 x RS 232 Converter
12. WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED IN NO EVENT SHALL THE AUTHOR BE LIABLE FOR ANY DIRECT INDIRECT INCIDENTAL SPECIAL EXEMPLARY OR CONSEQUENTIAL DAMAGES INCLUDING BUT NOT LIMITED TO PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES LOSS OF USE DATA OR PROFITS OR BUSINESS INTERRUPTION HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY WHETHER IN CONTRACT STRICT LIABILITY OR TORT INCLUDING NEGLIGENCE OR OTHERWISE ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE vi Features and Packing List Features e Allows IP control of two RS 232 enabled devices Supports Telnet and UDP protocols Each of the RS 232 devices can be addressed independently Configurable via Web server interface Independently configurable RS 232 baud rate and line delay for each RS 232 port Gefen Discovery Tool compatible Field upgradable firmware via Web server interface Locking power supply connector Surface mountable Packing List The IP to 2 x RS 232 Converter ships with the items listed below If any of these items are not present in your box when you first open it immediately contact your dealer or Gefen 1 x IP to 2 x RS 232 Converter e 1 x 5V DC Power Supply 1 x Quick Start Guide vii Table of Core Getting Started Introduction EE 2 TE EL el RO OE ON OE 4 Connection Instructions Sample Wiring Diagram
13. ample set add delim 1 Add delimiter mode to ON Related Commands set end del tset start del page 32 Advanced Operation set_device descr Commands Sets the device description The device description cannot exceed 30 characters in length Syntax set_device descr paraml Parameters param Description Example set_device descr LivingRoom Bridge2 Device Description changed to LivingRoom Bridge2 Related Commands show device descr page 33 30 chars max Advanced Operation Commands set end del Sets the end delimiter mode and value for the specified serial port The End Delimiter value must be specified in hexadecimal Before executing this command the Start Delimiter must be set using the set start del command Syntax set end del paraml param2 param3 Parameters param1 Serial port 1 2 param2 State 0 1 0 Off 1 On param3 End delimiter 00 FF Example set end del 1 1 ba End delimiter set to ON with a value of ba Related Commands tset add delim tset start del page 34 Commands set_gateway Sets the gateway address The gateway must be typed using dot decimal notation The matrix must be rebooted after executing this command The default gateway is 192 166 1241 Advanced Operation Syntax sgateway paraml Parameters param Gateway Example set_gateway 10 5 64 1 New IP Gateway set to 10 5 64 1 Related Commands s
14. ased control device see Sample Wiring Diagram below 2 Connect an RS 232 device to each of the RS 232 ports RS 232 1 and RS 232 2 on the IP to 2 x RS 232 Converter 3 Connect the included 5V DC locking power supply to the 5V DC power receptacle on the IP to 2 x RS 232 Converter Do not overtighten the locking power connectors 4 Connect the AC power cord from the power supply to an available electrical outlet Sample Wiring Diagram DB 9 CABLE CAT 5 CABLE wa RS 232 enabled Device RS 232 enabled Device EXT IP 2 RS2322 page 4 This page left intentionally blank This page left intentionally blank IP to RS 232 Converter Te Basic Operation Basic Operation IP Configuration Using Syner G When using the IP to 2 x RS 232 Converter for the first time it is recommended that the unit be configured using the Gefen Syner G Software Suite The Gefen Syner G Software Suite is free software that is available from the Gefen Web site 1 Download and install the Gefen Syner G Software Suite Download the application here http www gefen com synerg 2 Connect an Ethernet cable from the network to the IP control port on the product 3 Launch the Gefen Syner G Software Suite 4 Click the EXT IP 2 RS 2322 from the product list Select Function Discover and Configure IP Manage a Product My PC 10 5 64 90 00 1D 09 7E E1 1F Local Area Connectic v Product Name IP Address MAC A
15. ddress Description EXT CU LAN 10 5 64 138 00 1C 91 04 60 75 EXT CU LAN RD MASTER EXT HDKVM LAN S 10 5 64 67 02 1D 00 5A 8D 53 EXT DVIKVM LAN L S EXT CU LAN 10 5 64 130 00 1C 91 04 60 5D EXT CU LAN RDSLAVE EXT UHD 88 10 5 64 136 00 1C 91 04 90 03 EXT UHD 88 Device Settings Product Name EXT IP 2 RS2322 IP Mode Static v MAC Address 00 1C 91 03 F0 13 Web GUI Port 80 IP Address 192 168 1 72 Telnet Port 23 SubnetMask 255 255 255 0 Firmware Version 1 50 Gateway IP 192 168 1 254 Hardware Version Unavailable DNS Description IP_BRIDGE page 8 Basic Operation IP Configuration 5 Under the Device Settings section enter the desired IP address subnet mask gateway IP address Web GUI port and Telnet port in the supplied fields Device Settings Product Name EXT IP 2 RS2322 IP Mode Static v MAC Address 00 1C 91 03 F0 13 Web GUI Port 80 IP Address 10 5 64 254 Telnet Port 23 SubnetMask 255 255 255 0 Firmware Version 1 50 Gateway IP 10 5 64 1 Hardware Version Unavailable DNS Description IP_BRIDGE Web GUI Web Page Reboot Show Me Swe J If desired the Description field can be changed as well This is useful to identify if you have multiple units running on a network 6 Click the Save button at the bottom right corner of the screen 7 Click the Reboot button 8 Click the Web GUI link above the Reboot button to access the built in web interface Th
16. e following table lists the default IP settings for the IP to 2 x RS 232 Converter IP Address 192 168 1 255 Gateway HTTP Port page 9 RS 232 Interface RS 232 Interface 543 21 Basic Operation RS 232 Controller Switcher oo N OO BE ND oo N OO BE ND Only TXD RXD and GND pins are used RS 232 Settings Baud rate Data bits 8 Parity None Stop bits il Hardware flow control The command set on the following pages can be used to control the settings of the IP to 2 x RS 232 Converter via RS 232 page 10 Web Interface Using the built in Web Interface Access the built in Web interface by entering the IP address of the IP to 2 x RS 232 Converter that was used under the section IP Configuration page 8 Basic Operation The built in Web interface is divided into three pages RS 232 Network and System Each main page is represented by a tab at the top of the screen The RS 232 page will always be displayed first Gefen IP To RS 232 Bridge EXT IP 2 RS racer man RS 252 Mode Soloct the moda for he soloctod pot TGP Bridge Connect to the device using TGP Slower than UDP guaranteed packet order 2 using UDP faster then TCP no guaranteed packet R 232 SETTINGS Baud Rate Saloct the connected device s baud rate BRIDGING SETTINGS Line Deia re ms iFtime elapses larger than defined here Time out must be an integ
17. er 255 Help Click the Help button to display context sensitive help for the current page The help window can be moved to any position within the Web browser window RS 232 Settings Help Select RS 232 Port Select the RS 232 port to configure 2 ports are available NOTE Save settings 4 selecting a new port to configure or changes will be lost Description Enter an optional description for the RS 232 output 20 character max RS 232 Mode Select the mode for the selected port TCP Bridge Connect to the device using TCP Slower than UDP guaranteed page 11 Web Interface Select R 232 Port 1 Description None RS 232 Mode TCP Bridge Basic Operation Gefen IA To RS 232 Bridge EXT IP 2 RS2322 syst 2mp Select RS 232 Port Select the RS 232 port from the drop down list Options 1 2 Description Enter a description for the device that is connected to the selected RS 232 port RS 232 Mode Select the desired mode from the drop down list Options TCP Bridge UDP Bridge Terminal page 12 Web Interface RS 232 Settings Baud Rate Data Bits Parity Stop Bits Basic Operation Gefen IP To RS 232 Bridge EXT IP 2 RS2322 Baud Rate Select the baud rate used by the RS 232 device from this drop down list Options 110 300 600 1200 2400 4800 9600 14400 19200 28800 Data Bits Select the number of data bits in each character from th
18. er Param s in bridge mode UART 1 Line Delay 1000ms Time To Force Send 30ms Count Byte To Force Send 100 Add Delimiters In Data False Use Start Delimiter False Start Delimiter Size 1 Start Delimiter Value A0 Use End Delimiter True End Delimiter Size 1 Start Delimiter Value BO Related Commands set_add delim set_end_del set_send byte cnt t set send time out tset serial params tset start del page 55 Advanced Operation show device descr Displays the device description Syntax show device descr Parameters None Example show device descr Device Description IP BRIDGE Related Commands set device descr page 56 Commands Advanced Operation show ipconfig Displays the current TCP IP and UDP settings Syntax show_ipconfig Parameters None Example show_ipconfig MAC addr 00 1C 91 01 0F FF P addr 10 5 64 254 Net Mask 255 255 255 0 Gateway 192 168 1 254 Web Server Port 80 TCP Terminal Server Port 23 TCP Terminal Access Enabled TCP Terminal password at login is set to OFF UDP Access Disabled UDP Server Port 50007 Enable UDP Echo Disabled UDP Remote IP 192 168 1 80 UDP Remote Port 50008 TCP Bridge 1 Port 49200 TCP Bridge 2 Port 49201 UDP Local Bridge 1 Port 50200 UDP Remote Bridge 1 IP 192 168 1 180 Port UDP Remote Bridge 1 Echo Disabled UDP Local Bridge 2 Port 50201 UDP Remote Bridge
19. et_add delim set_ipadd set_netmask show_ipconfig page 35 Advanced Operation set http port Commands Specifies the Web server listening port The unit must be rebooted after executing this command The default port setting is 80 Syntax t set http port paraml Parameters param1 Port Example set_http_port 82 New HTTP port set to 82 Related Commands set_gateway set_ipadd set_netmask show_ipconfig page 36 1 1024 Advanced Operation Commands set_ipadd Specifies the IP address of the IP to 2 x RS 232 Converter The IP address must be specified using dot decimal notation The unit must be rebooted after executing this command The default IP address is 192 168 1 72 Syntax set_ipadd paraml Parameters param IP address Example set_ipadd 10 5 64 187 New IP set to 10 5 64 187 Related Commands set_gateway set_http_port set end del show_ipconfig page 37 Commands set_netmask Sets the subnet mask The subnet mask must be entered using dot decimal notation The unit must be rebooted after executing this command The default net mask is 255 255 2550 Advanced Operation Syntax snetmask paraml Parameters param Net mask Example snetmask 255 255 0 0 New IP Mask set to 255 255 0 0 Related Commands set_gateway set_ipadd set_http_port show_ipconfig page 38 Advanced Operation Commands set_send_byte c
20. ets the mode of the specified serial port The default mode for all serial ports 1 2 is TCP Bridge mode Syntax Advanced Operation t set serial mode paraml param2 Parameters param1 Port ss 2 param2 State 1 3 TCP bridge 2 UDP bridge Terminal mode Example set serial mode 1 2 Serial port 1 working mode is TCP Bridge Mode Related Commands show serial mode page 42 Commands set serial params Assigns the settings to the specified serial port Syntax t set serial params paraml param2 param3 param4 param5 param6 Advanced Operation Parameters param1 Port tend param2 Word length 5 8 param3 Stop bits 1 2 param4 Parity param5 Baud rate param6 Line delay ms 0 10000 continued on next page page 43 E io L o a Oo je D o E gt je lt Example set_serial params 1 8 1 N 19200 1000 Serial port 1 parameters word length 8 bits Stop bits 1 bit Parity None Baud Rate 19200 Bps Line Delay 1000 ms Related Commands show_serial_params page 44 Commands Commands set start del Sets the Start Delimiter mode and value for the specified serial port The Start Delimiter must always be specified before the End Delimiter Syntax Advanced Operation t set start del paraml param2 param3 Parameters param1 Serial port 1 2 param 2 State 0 1 TCP bridge 2 UDP bridge Terminal
21. im paraml pram2 Paraml Serial Port 1 2 Param2 On QO Off e g set_add_delim 1 0 help full Cmd show serial params Show Serial Port Parameters Syntax show serial params Param Serial Port 1 2 e g show serial params 1 Cmd set serial mode Set Serial Port mode Syntax set uart mode paraml param2 Paraml Serial Port 1 2 Param2 1 Terminal for Portl only 2 TCP Bridge 3 UDP Bridge e g set_serial mode 1 2 continued on next page page 30 Advanced Operation help show ipconfig set ipadd set netmask set gateway set http port set tcp term port set udp port show ver data show telnet pass set telnet pass use tcp term pass set udp rip set udp rport use udp access use udp echo use tcp access set serial params show serial params set serial mode show serial mode show serial connect set serial descr show serial descr set tcp br port set udp br port set udp remote br set udp echo br use discovery set add delim set start del set end del set send time out set send byte cnt show del prms set device descr show device descr show me system wide reset page 31 Commands Advanced Operation Commands set add delim Enables or disables the option to include a delimiter as part of the data sent to the control system Syntax set_add delim paraml param2 Parameters param1 Value 1 2 param 2 State 0 1 0 Off Al On Ex
22. im set device descr Scemendmdaik set_gateway Sots miitats omy orate set_ipadd set_netmask set send byte cnt seel endldime lo set serial descr pet sede set serial params set Serene ile set tep br port Set tea tenn pore set telnet pass set udp bri port set udp echo br set uidplpoot set udp remote br Set biel 19 set udp rport show del prms show device descr show ipconfig show me show serial deser show serial mode help Displays a list of all available commands Enables or disables option to add delimiter to data Sets the device description Sets the end frame delimiter Sets the gateway router IP address Sets the HTTP listening port of the IP to RS 232 Converter Sets the IP address of the IP to RS 232 Converter Sets the subnet mask of the IP to RS 232 Converter Sets the send byte count value for bridging mode Sets the time out value for sending data Assigns a description to the specified RS 232 port Sets the serial mode TCP UDP or Terminal Assigns the settings to the specified RS 232 port Sets the Start Frame delimiter Sets the TCP bridge listening port Sets the TCP terminal listening port Sets the TCP terminal password Sets the UDP bridge listening port Enables or disables UDP bridge echo Sets the UDP listening port Assigns the UDP bridge settings for the specified RS 232 port Sets the remote UDP IP address Sets the UDP remote port Dusplays the current delimiter parameter
23. is drop down list For most applications 8 data bits should be selected 9 data bits are rarely used Options 8 9 Parity Select the parity bit type from this drop down list Options None Even Even Stick Odd Odd Stick Stop Bits Select the number of stop bits from this drop down list Options 1 2 page 13 Basic Operation Web Interface Bridging Settings Line Delay ms Force Send ms Force Send bytes Add Delimiters to data sent Use Start Delimiter Start Delimiter Value Use End Delimiter End Delimiter Value TCP Port UDP Local Port Line Delay ms Enter the line delay in this field Range 0 10000 Force Send ms If no data is received from the controlled device within the specified time interval send the collected data to the control system Range 0 30 Force Send bytes If the specified number of bytes is received from the controlled device send the collected data to the control system Range 0 255 page 14 Web Interface Bridging Settings Line Delay ms Force Send ms Force Send bytes Add Delimiters to data sent Use Start Delimiter Start Delimiter Value Use End Delimiter End Delimiter Value TCP Port UDP Local Port S AI ie he ok wn faal Add Delimiters to data sent Include the delimiter characters in the data sent to the control system Check the Add box to enable thi
24. me Old Password New Password Confirm New Password Terminal Port Enable UDP Access UDP Port Enable UDP Echo Destination UDP IP Address Destination UDP Port Enable Discovery Default Settings Network Device dependent cannot be changed Static 192 168 1 72 2855525510 192 168 1 254 80 Disabled Disabled Admin cannot be changed default password is Admin 23 Disabled 50007 Disabled 192 168 1 80 50008 Enabled page 73 Specifications RS 232 IP control 2 x DB 9 male o 1 x RJ 45 1 x 5V DC locking 1x LED blue 1 x Tact type recessed Appendix Power Power indicator IP Reset button 5V DC 1W max Power Power consumption 43 x1 x 3 4 110mm x 26mm x 86mm Dimensions W x H x D Unit Weight 0 35 Ibs 0 16 kg page 74 This page left intentionally blank 7 GEFEN 20600 Nordhoff st Chatsworth CA 9131 1 800 545 6900 818 772 9100 fax 818 772 9120 www gefen com support gefen com
25. nced Operation Parameters param1 Value 0 1 Disable UDP access Enable UDP access Example use_ udp access 1 UDP Access is set to Enabled Related Commands set_udp_br port set_udp_echo_br set_udp remote br set udp rip set_udp_rport page 68 Commands use udp echo Enables or disables UDP echo Syntax use udp echo paraml Advanced Operation Parameters param1 Value 0 1 Disable UDP echo Enable UDP echo Example use udp echo 1 UDP echo is set to Enabled Related Commands set udp echo br page 69 This page left intentionally blank IP to RS 232 Converter 4 Appendix Appendix Default Settings The following table lists the default setting of the IP to 2 x RS 232 Converter as displayed under the built in Web interface Select RS 232 Port Description RS 232 Mode Baud Rate Data Bits Parity Stop Bits Line Delay ms Force Send ms Force Send bytes Add Delimiters to data sent Use Start Delimiter Start Delimiter Value Use End Delimiter End Delimiter Value TCP Port UDP Local Port Destination IP Destination Port UDP Echo RS 232 1 None TCP Bridge 19200 8 None 1 0 30 100 Disabled Disabled 0 Disabled 0 49200 50200 192 168 1 180 50000 Disabled page 72 Appendix MAC Address Mode IP Address Subnet Gateway HTTP Port Enable TCP Access Require Password on Connect User Na
26. nt Sets the send byte count value for bridging mode Syntax set_send byte cnt paraml Parameters param Serial port s2 param2 Byte count 0 255 Example set_send_byte cnt 1 100 UART 1 bridging send byte count limit is set to 100 bytes Related Commands set_add delim set_end_del set_serial_mode set_start_del page 39 Advanced Operation Commands set send time out Sets the time out value for sending data collected from a device to the control system in Bridging Mode when a Start Delimiter and End Delimiter have been set If no data has been collected for the specified time the data is sent without waiting for the End Delimiter Syntax t set send time out paraml Parameters param1 Serial port 1 2 param2 Time out ms 0 255 Example set_send_time_out 1 30 UART 1 bridging sent Time Out is set to 30 ms Related Commands set_add delim set_end_del set_serial_mode set_start_del page 40 Advanced Operation Commands set_serial descr Assigns a descriptor to the specified serial port The serial port description cannot exceed 20 characters in length The default description is None Syntax set_serial descr paraml param2 Parameters param Port 1 2 param2 Description 20 chars max Example set_serial descr 1 DVD Ctrl Serial port 1 Description DVD_Ctrl Related Commands show_serial_descr page 41 Commands set serial mode S
27. ord updated to b055man Related Commands set_tcp_br_ port page 48 Advanced Operation Commands set_udp br port Sets the UDP bridge listening port The default UDP bridge port settings for RS 232 1 and RS 232 2 ports are 50200 and 50201 respectively Syntax set udp br port paraml param2 Parameters param Serial port 1 2 param2 Port 1 65535 Example set_udp_br port 1 50200 UDP Bridge 1 port set to 50200 Related Commands set_tcp_br_port set_tcp_term port set_start_del set_udp remote br set udp rip set_udp_rport page 49 Commands set udp echo br Enables or disables UDP bridge echo Syntax set_udp_echo br paraml param2 Advanced Operation Parameters paraml Serial port 2 param 2 State 0 1 Disabled Enabled Example set_udp_echo br 1 1 The echo of UDP Bridge port 1 is enabled Related Commands set_udp_ br port set_udp remote br set udp rip set_udp_rport page 50 Commands set_udp port Sets the UDP server listening port Syntax Advanced Operation set_udp port paraml Parameters param1 Serial port 1 65535 Example set_udp port 50007 New UDP server port set to 50007 Related Commands set_udp_br_ port set_udp remote br set udp echo br set udp rip set_udp_rport page 51 Advanced Operation Commands set_udp remote br Assigns the UDP Bridge settings for the specified serial
28. riods of time Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped Batteries that may be included with this product and or accessories should never be exposed to open flame or excessive heat Always dispose of used batteries according to the instructions Warranty Information Gefen warrants the equipment it manufactures to be free from defects in material and workmanship If equipment fails because of such defects and Gefen is notified within two 2 years from the date of shipment Gefen will at its option repair or replace the equipment provided that the equipment has not been subjected to mechanical electrical or other abuse or modifications Equipment that fails under conditions other than those covered will be repaired at the current price of parts and labor in effect at the time of repair Such repairs are warranted for ninety 90 days from the day of reshipment to the Buyer This warranty is in lieu of all other warranties expressed or implied including without limitation any implied warranty or merchantability or fitness for any particular purpose all of which are expressly disclaimed 1 Proof of sale may be required in order to claim warrant
29. s feature Options Enable checked Disable unchecked Use Start Delimiter Includes the Start Frame Delimiter used at the end of the preamble of an Ethernet frame Options Enable checked Disable unchecked Start Delimiter Value This value can be up to three ASCII characters 3 bytes in length The value must be entered in hexadecimal e g ODOA which is CR LF The Start Frame Delimiter Value is used by some control systems to filter incoming data Contact Gefen Technical Support for details if you need to use them Range 00 FF wildcard characters such as are acceptable Use End Delimiter Includes the End Frame Delimiter used at the end of a transmission frame Options Enable checked Disable unchecked page 15 S 4 ie L Q ie wn faal Web Interface Bridging Settings Line Delay ms Force Send ms Force Send bytes Add Delimiters to data sent Use Start Delimiter Start Delimiter Value Use End Delimiter End Delimiter Value TCP Port UDP Local Port End Delimiter Value This value can be up to three ASCII characters 3 bytes in length The value must be entered in hexadecimal Range 00 FF wildcard characters such as are acceptable TCP Port Enter the TCP port in this field Range 0 65535 UDP Local Port Enter the UPD local port in this field Range 1024 65535 page 16 Web Interface UDP Echo
30. s for the specified serial port Displays the device description Displays the current TCP IP and UDP settings of the IP to 2 x RS 232 Converter Enables or disables the flashing of the LED on the device Displays the current description of the specified RS 232 port Displays the mode of the specified RS 232 port continued on next page page 28 Advanced Operation show serial params show telnet pass show ver data system wide reset use discovery use Eg CESSE use_tcp term pass use udp access use udp echo Commands Displays the settings of the specified RS 232 port Displays the current TCP terminal password Displays the firmware and hardware version of the IP to RS 232 Converter Restarts the IP to 2 x RS 232 Converter according to the supplied parameter Enables or disables discovery mode Enables or disables TCP access mode Enables or disables the password prompt at the beginning of a Telnet session Enables or disables UDP access Enables or disables UDP echo page 29 Advanced Operation Commands help Displays help on a specific command If no command is specified param7 then a list of all available commands will be displayed Set param1 to full to display a list of all commands Syntax help Parameters param1 Command optional Example help set add delim Cmd set add delim Set Add delimiter mode Syntax set add del
31. vides automatic download and installation of firmware upgrades for this product Syner G is also used to configure this product on a network Download the application here http www gefen com synerg IP to 2 x RS 232 Converter is a trademark of Gefen LLC 2015 Gefen LLC All Rights Reserved All trademarks are the property of their respective owners Gefen LLC reserves the right to make changes in the hardware packaging and any accompanying documentation without prior written notice O X ce amp This product uses UL or CE listed power supplies IwIP is licenced under the BSD licence Copyright c 2001 2004 Swedish Institute of Computer Science All rights reserved Redistribution and use in source and binary forms with or without modification are permitted provided that the following conditions are met 1 Redistributions of source code must retain the above copyright notice this list of conditions and the following disclaimer 2 Redistributions in binary form must reproduce the above copyright notice this list of conditions and the following disclaimer in the documentation and or other materials provided with the distribution 3 The name of the author may not be used to endorse or promote products derived from this software without specific prior written permission THIS SOFTWARE IS PROVIDED BY THE AUTHOR AS IS AND ANY EXPRESS OR IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO THE IMPLIED
32. y Customers outside the US are responsible for shipping charges to and from Gefen Copper cables are limited to a 30 day warranty and cables must be in their original condition The information in this manual has been carefully checked and is believed to be accurate However Gefen assumes no responsibility for any inaccuracies that may be contained in this manual In no event will Gefen be liable for direct indirect special incidental or consequential damages resulting from any defect or omission in this manual even if advised of the possibility of such damages The technical information contained herein regarding the features and specifications is subject to change without notice For the latest warranty coverage information refer to the Warranty and Return Policy under the Support section of the Gefen Web site at www gefen com Contacting Gefen eed Technical Support 818 772 9100 800 545 6900 8 00 AM to 5 00 PM Monday Friday Pacific Time Fax 818 772 9120 Email Support gefen com Web http www gefen com Mailing Address Gefen LLC c o Customer Service 20600 Nordhoff St Chatsworth CA 91311 Product Registration Register your product here http www gefen com kvm Registry Registration jsp Operating Notes s Always make sure that the IP to 2 x RS 232 Converter is running the latest firmware The Gefen Syner G Software Suite is a free downloadable application from Gefen that pro
Download Pdf Manuals
Related Search
Related Contents
Rinnai RHFE-750ETRA User's Manual HTM Manual, English Exhibitor Service Manual GPS Datalogger User Manual Version 25b Copyright © All rights reserved.
Failed to retrieve file