Home

AS-2E audio description user manual

image

Contents

1. Menu Num Heading Automation Function 29 EDIT none Pressing the return key switches the system into an editing mode The memory to be edited is displayed on the top line this can be adjusted by pressing the display button or by turning the associated knob The first 6 characters form the text of the message the next two digits define the foreground and background colours The last digit defines whether the text is flashing F or normal N the default is normal so the N may be omitted The colours are defined as O white 1 cyan 2 yellow 3 green 15 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com 4 magenta 5 blue 6 red and 7 black Defining either colour to be red 6 will cause an alarm to be generated when that A F D message or error message occurs This does not apply to the channel ID The memory locations are defined as 0 ID 1 OK 2 Absent 3 Swapped 4 Inverted 5 Swapped and Inverted 6 CRC error 7 Swapped and CRC error 8 Inverted and CRC errorand 9 Swapped Inverted and CRC error When editing of a message is complete pressing return will revert the system into normal mode 29 Master Meee If this system has a remote master Display display system Eyeheight product system code MD 9 then this must be set to ON Otherwise it must be O
2. Sampling Freg0 combined with Sampling Freg1 Link sets the Sampling Freguency data on the channel status bits Emphasis0 Emphasis1 Function No Link No Link Undefined Emphasis Link No Link No Emphasis No Link Link 50 15uS Emphasis Link Link CCITT J17 Emphasis Sampling Freg0 Sampling Freq1 Function No Link No Link 32 0K Sampling Link No Link 48 0K Sampling No Link Link 44 1K Sampling Link Link Sampling Freg Not Indicated Figure 12 Jumper links for the AES output configuration 21 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com
3. _ y Te i i a en a les a ae ym Ta i z F a _ D 2 AD 2E audio description monitoring units HE ED user manual i SIOE OC IG uuig NG GU A E Y GG UY 4 1 1 Associated Equipment for the AD 2 AD 2E 9 eeeee inneu inneu 5 i Pu PS te oc ae Ro ene E E 5 1 1 2 Control SurfaCeS eenni rr YY Y YY LILI HY LLALL E EEEE EEEE EE nET pei 6 y NAS eU eU a ERFYN S TW EFFRO N HYF TN ENYN ND 7 2 1 Installation of the AD 2 AD 2E product 9999 eei irr YL HF Y nnion 7 2 2 Installing the AD 2 AD 2E into a flexiBOX cceecceeseseeeeeeeeeeeseeeeeesaeees 7 20 Connecting toan AD 2 AD 2E iasscsiassd icsiedsdecsescannaesbdsdioededdeeeiesteenhicderesices 7 2 4 Connecting Panels to the AD 2 AD 2E ccccceececceeeceseeeeeeeeeesaeeeeeeeees 9 POPON EFT ote se pas needa nostro nanan antes E EEE 11 3 1 Manual control of the AD 2 AD 2E 999 eerrnYYY YY HYLAW RHY FY Yr nnnnen 11 3 2 Automation Control of the AD 2 AD 2E 2 00 cceeecccccecsssseeeeeeeeseesaeeeeeeees 11 3 3 Operational Menus for the AD 2 AD 2E ccceeecccccceeseeeseeeeeeesaeeseeeeeees 12 A et ole ANOS GIN lt FFTNFAF WE HFRHFO Y TN FAR FFF EFFRO A FFF 19 4 1 Technical Specification for the AD 2 cccccccecceceeeeseeeeeeeeeesseaaaeeeeeees 19 4 2 Technical Specification for the AD 2E cccccccccceesesesseeeeeeeeseaaaeeeeeess 19 4 3 Technical Specification fo
4. A O 5 O o 6 8 AES tb AD monitor mix 9 AES 2a AD reclock output 10 AES 2a AD reclock output 11 AES 2b AD reclock output 12 AES 2b AD reclock output 13 Notused S 14 Notused i O p15 GND _ O Figure 6 AD 2 Rear connections Function pt Notused S O p 2 Notused o 3 Notused o 4 Notused S O 5 AES ta AD monitor mix 6 AESIaAD monitor mix 8 AES 1b AD monitor mix 9 10 1 12 133 a 15 PGM Video PGM Video on screen display Emb Aud on 1 2 Emb Aud on 1 2 Not used Aud Desc on 3 4 Aud Desc or Mixed Emb Aud and Aud Desc on 3 4 Figure 7 AD 2E rear connections 8 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com BNC connections are S not used Relay 1 contact1 AD alarm Relay 1 contact2 AD alarm Contact 1 amp 2 make when an AD error condition occurs M E Relay 2 contact1 AD alarm accepted Relay 2 contact2 AD alarm accepted Contact 1 amp 2 make when the error condition is cleared by the input GPI This will clear when there are no more errors on the AD feed GPI input Accept current alarm The user shorts this to ground to clear the AD alarm tally relay output Figure 8 GPI and alarm connection details 2 4 Connec
5. eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com han DH HOE Pr re sh LLW GCE A pa P A y cy y o PsSWHHIHHW ee a D o H a mail a UL 6 3 O5 O3 z e p Sleens aaan EL CECECOCCERCE 41 eo 7 Nu o o gt A er YT o y 9 j5 Uu Tay IN Figure 1 The AD 2 AD2E audio description module Figure 2 On screen display of the AD 2 AD 2E 1 1 Associated Equipment for the AD 2 AD 2E The AD 2 AD 2E is a module and requires both a chassis and a control surface to function 1 1 1 Chassis Types e flexiBox is a 1RU chassis The order code is FB 9 This will hold a maximum of three AD 2 AD 2E modules with Hot Swap redundant PSU option and Hot Swap AD 2 AD 2E modules e maxiBox is an alternative low cost 1RU chassis The order code is MX 9 This also will hold a maximum of three AD 2 AD 2E modules but it has no redundant PSU option and the AD units must be factory fitted DD eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com Figure 3 FlexiBox with flexiPanel fitted 1 1 2 Control Surfaces e flexiPanel is a IRU control surface that fits on the Front o
6. saves Saves current configuration as MEM3 configuration memory 3 43 SAVE 1 saves Saves current configuration as MEM4 configuration memory 4 17 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com Menu 44 47 Power On Memory Press PREV to navigate Heading Automation Function Save 1 to save Saves current configuration as Power On memory Power On memory Memory 45 Recall 1 to recall Recalls the Power On memory Power On memory configuration Memory 46 Total 1 to cause This puts all current and power on Reset Total Reset default settings to the factory default 47 Software This displays the current software version version 18 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com 4 Technical Appendix 4 1 Technical Specification for the AD 2 4 2 Technical Specification for the AD 2E AES audio Inputs AES audio Outputs 4 AES outputs for monitoring and AD reclocking Type Of Outputs AES 2 48KHz description data on 3 4 4 3 Technical Specification for the GPl Tally connector GPI inputs 1 off short to ground to activate for alarm accept Relay closure outputs 2 off isolated relay c
7. 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com Menus 08 11 Screen display select Press NEXT PREV to navigate Menu Num Heading Automation Function 8 Audio ie Pressing this will turn on or off the Audio Bar Default is On Bar 9 Fader o Pressing this will turn on or off the Fader Bar Default is On Bar 10 Pan E Pressing this will turn on or off the Pan Bar Default is On Bar 11 Bar UN a The fade level of the Audio Fader and Fader Pan bar overlaid on to the video image Menus 12 15 Ident bar size and position Press NEXT PREV to navigate Menu Num Heading Automation Function 12 Text a anes This sets the horizontal size of the text H size 13 Text ee ieee This sets the vertical size of the text V size 14 Ident eo This sets the horizontal position of the H posn Ident bar on the video image 15 Ident an _ This sets the vertical position of the V posn Ident bar on the video image 13 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com Menus 16 19 Audio bar graph size and position Press NEXT PREV to navigate Menu Num Heading Automation Function 16 Audio aed The width of the Audio bar Width efault Is 17 Audio E The length of the Audio bar The size 2 full following options are available 1 4 1 2 Default i
8. 2 AD 2E module Information about this is given in this manual Figure 9 l Bus connection from chassis to panel N B From 1 10 02 Eyeheight introduced a change in the flexiBox Chassis Most versions now have two 9 way connectors on the rear labelled I Bus and D Bus The I Bus connector is the same as the previously labelled Can B connector Although a maxiBox is shown in this diagram the same arrangement applies for a flexiBox chassis 10 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com 3 Operation 3 1 Manual control of the AD 2 AD 2E Manual Control of the AD 2 AD 2E is done using one or more of the following control surfaces e The 1RU FP 9 flexiPanel e The FP10 Desk mounting panel The FP 9 and the FP 10 have identical manual control systems The FP 10 is simply a desktop version of the FP 9 The AD 2 AD 2E is as are all genetics modules controlled using a set of MENUS Each of these menus contains up to 3 parameters that are adjusted using the rotary digipots The Menus define all of the adjustable operational parameters in the AD 2 AD 2E Pressing the rotary digipots brings the parameter to its default value Device selection is done using the device select switches which when pressed will offer the name of the device in the LCD Window Modules can
9. E Sh Hein we LK12LK10 eF sma WE Data eee Format WWF Jumpers ap TEU an siinne a 77 PE hasta E E ir CEPEJ ti ET MHWWFHYUDUWNWEUU NENUSHNUHDEUUNU iae ET mr ay 19 0120 9voUz2 a Hie is Bi a Bey ale Tihs Tn Yan rege y a oe a z 3 a a Eo om RENA an Figure 11 jumpers on the AD 2 AD 2E card Ty ua 20 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com tink No Function of LK1 gt LK10 Links of LK1 gt LK10 Links Standard Emphasis1 combined with Emphasis0 sets the No Link Equalisation data on the channel status bits Emphasis0 combined with Emphasis1 sets the Link Equalisation data on the channel status bits ae Stereo mode set in Channel Status bits Link to a Link De E erh Sane SHS BERS dea 1 User Bit set in Channel Status bits Link to clear Link 4 oT Os woeam Diagnostic MUST BE LINKED ma Link 7 Validity Bit set in Channel Status bits Link to clear Bit set in Channel Status bits Link to clear No Link Link Sampling Freg1 combined with Sampling Freg0 No Link sets the Sampling Frequency data on the channel status bits 3 Non Audio Bit set in Channel Status bits Link to No Link set Professional Mode Bit set in Channel Status bits Link Link to set
10. FF 30 ti SPARE DS P 8t ff SPARE Menus 32 35 Embedder Controls AD 2E only Press NEXT PREV to navigate Heading Automation Function Embedder 0 09 Controls embedder for output video On Off 2 NotFit Program audio in groups 1 2 and audio description or mixed of program and audio description in groups 3 4 Not fitted in AD 2 AD 2E only 33 Re aes Individual control for embedding Embed 2 NotFit audio description or mixed of AD into program and audio description in groups groups 3 4 of output video 3 4 Not fitted in AD 2 AD 2E only ooa ff SPARE 16 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com 88 TSPARE Menu 36 39 Memory Recall Press NEXT PREV to navigate Menu Num Heading Automation Function 36 MEM1 1 recalls Recalls configuration memory 1 memory 37 MEM 2 1 recalls Recalls configuration memory 2 memory 38 MEM 3 1 recalls Recalls configuration memory 3 memory 39 MEM 4 1 recalls Recalls configuration memory 3 memory Menu 40 43 Memory Save Press NEXT PREV to navigate Menu Num Heading Automation Function 40 SAVE 1 saves Saves current configuration as MEM1 configuration memory 1 41 SAVE 1 saves Saves current configuration as MEM2 configuration memory 2 42 SAVE 1
11. be acquired and then de acquired using the set up switch For a full description of the operation philosophy of the geNETics system refer to the geNETics User Guide section Operation of the flexiPanel A full list of the Menus and their functions are given in section 3 of this chapter 3 2 Automation Control of the AD 2 AD 2E Automation of the geNETics products is achieved via an RS422 port This port is marked RS422 on the rear of a flexiBox For the port to work a flexiPanel MUST be connected locally on the front of the flexiBox Automation control of the AD 2 AD 2E can be done using two protocol methods e geNETics Automation Protocol e PresTX Automation Protocol Genetics protocol is described in detail in the GeNETics User Guide section titled Automation Protocol on the geNETics Platform The menu list in section 3 of this chapter contains the data information for the protocol Pres TX Automation Protocol is used only for the PresT X Presentation Mixer and channel branding system In this case an AU 2 Automation card is also required Refer to the PresTX Product manual On most flexiBoxes later than 1 10 02 the RS422 port has been replaced by a D Bus Port The D Bus port is for High Speed data transfer and is not used for serial control In order to achieve serial control of any products on an Bus network Eyeheight Ltd have developed a RS232 gt 1 bus converter dongle DG 9 which enables g
12. csesccceseseeeesesaneeeessenseneeeneaaes 20 Figure 12 Jumper links for the AES output configuration cseeeeeeeeeeeeeeeees 21 a eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com 1 System Overview This manual describes the function of the AD 2 and AD 2E units The AD 2 monitors AES audio description data and decodes both PAN and FADE and AUDIO LEVEL information The AD 2E has the same functionality but works on embedded audio The modules flag suitable alarms and display the information in vision overlaid onto the video screen All the modules are fully compatible with the eyesight monitoring system A GPl Alarm option is available for both the AD 2 and the AD 2E Alarm relay closures which can be cleared by externally provided GPI switching are also included e The AD 2 monitors AES audio description data the AD 2E monitors embedded audio description data e The AD 2 AD 2E provides a monitoring mix output of combined programme audio and audio description as decoded A re clocked AD output is also provided e Groups 1 amp 2 of the output video will always be the original program audio e The AD 2E has the facility to embed the mixed programme with audio description or original audio description into audio groups 3 amp 4 of the output video This will only happen when
13. ear of the flexiBox are 6 slots for Products Remove any pair of spare blanking plates one above another There are 2 off M2 5 Screws which reguire unfastening for each blanking plate Slide the Product PCB into the spare slots and firmly push it home Use the four thumbscrews to fasten the unit in place Take care that the ribbon cable for the upper circuit board stays attached to the lower board Now refer to the GeNETics User Guide If your system consists of a single flexiBox with a single flexiPanel then refer to the section titled flexiPanel Auto Set up If your system is part of a network with more than one flexiPanel then refer to the section titled flexiPanel Manual Set up This will guide you through acquiring your product as a device on the flexiPanel 2 3 Connecting to an AD 2 AD 2E Connections for the AD 2 AD 2E are shown below For an AD 2E all the audio information programme and audio description is on the embedded audio feed Programme material is on channels 1 2 and the audio description is assumed to be on audio 3 4 The AES monitoring outputs on the AD 2E are 48K but not clock synchronous to the incoming video feeds 7 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com Pin Number Function PGM Video PGM Video on screen display i i O 1 Oo 2 O 3 O O
14. f a 1RU flexiBox The order code is FP 9 A FlexiPanel can also be used in conjunction with a miniBox in this case the extra accessory Order code RR 9 will be reguired e FP 10 is a desk mounting control surface Order code FP 10 This unit is a modular unit which can be used in conjunction with the units below eyeheight coD D o s oC P o o o o Figure 4 Desktop modular panel FP 10 ey height Figure 5 1RU panel FP 9 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com 2 Installation 2 1 Installation of the AD 2 AD 2E product If this unit is already pre installed in a flexiBox FB 9 or a maxiBox with either a local or a remote panel from the factory then refer to the Hardware Installation Guide which will be enclosed with the system If this unit is pre installed in a miniBox MB 9 then also refer to the Hardware Installation Guide which will be enclosed with the system If this unit has been ordered separately we assume here that you already have a flexiBox system with a Flexipanel and that the flexiBox has at least two spare slots for an AD 2 AD 2E card 2 2 Installing the AD 2 AD 2E into a flexiBox To install the AD 2 AD 2E into a flexiBox it is desirable but not necessary to power down the flexiBox Follow these instructions On the r
15. losure outputs up to 1 Amp current flow One for Alarm and one for alarm accept Current Consumption lt 300mA at 5V 4 4 Jumpering the I BUS CAN BUS Termination The I BUS Network is the control system under which all Products and Panels are networked together Under certain circumstances it is necessary to terminate the network This can be done on a Panel or a Product To terminate this product locate J6 on the AD 2 Processor Card supplied which is between U1 The large square chip and the Edge connector This is on the half of the card 19 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com labelled CHP 100 Spartan2 Processor Jumper this with a 2mm link JI I I Tit eit 8 i d 6 LLTD H FE hig ts ji a i J i n pilonii nn i i me j ilea i 5 h Tr Lu A Uc A W R OE bo bbe bbaeg oad 19 0120 SDO rk ta sa a y Pi Eb wel ater i fl el yl ty WL I Rh Mans a A U d HOS 9320tig ENY LHY 5 PE dHJ MEL l PEE ep Figure 10 Location Of l Bus Termination Link 4 5 CHP 100 SDI TG GPI Card 4 5 1 Jumper Links on the Timecode and GPI 1 0 card The AES output has a number of jumper links which effect the formatting of the AES output data ian fi 2 Fe TPE ee ee oe Y ee eo BG
16. r the GPI Tally connector eeeennn 19 4 4 dumpering the l BUS CAN BUS Termination 19 T5 CHFEIOO DETUFGFO UC 1 GN go GO 20 4 5 1 Jumper Links on the Timecode and GPI I O card 20 aia Table of Contents eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com Table of Figures Figure 1 The AD 2 AD2E audio description module ccccccseeeeeeeeeeeeeeeeeeeeees 5 Figure 2 On screen display of the AD 2 AD 2E 99 eeirru Y LY FL FY YY r LL uu Yno 5 Figure 3 FlexiBox with flexiPanel fitted 99 999 YYYnYY HAY HYAY EAR HYAY AY LLYRY Yr nnHyon 6 Figure 4 Desktop modular panel FP 10 ccccccccseseceeceeseeeeeeseseeeeseuaeeeeeenaaaes 6 Figure 5 1RU panel FP 9 uu ccccccccsssececesseceseseeceeeeeeseaseeessaeeessaseeessanseesseges 6 Figure 6 AD 2 AD 2E Rear connections ccccseeccceeeeeceeeeeeeeeseeeeeseeeesaneeesaees 8 Figure 7 AID 2E rear CONN CCHONS ea Dn O Do GO GO CG aU GR bu Good 8 Figure 8 GPI and alarm connection detailS eeueui erru Yr YY FA LL LL LL LLuuuuuu 9 Figure 9 l Bus connection from Chassis tO Panel cceeeeeeeeee eee eeeeeeeeeeeeaeaeees 10 Figure 10 Location Of I Bus Termination Link cccccssseeeeceeeeeeeeeeeeeeeeeenaaees 20 Figure 11 jumpers on the AD 2 AD 2E card ce
17. reater flexibility of products on the l Bus network whilst using the same protocols as the RS422 port Please refer to the User guide for the DG 9 eyeheight dongle and set up software 11 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com 3 3 Operational Menus for the AD 2 AD 2E Menus 00 03 Top Level Menus a _ Heading Automation Function User nong This is the user programmed name Name for this unit see genetics user guide for information as to how to program names or aliases Software pone This displays the current software version version Monitoring at This adjusts the gain volume of the output FF 77dB Programme AD mix AES monitoring gain output NEXT none Prompts the user to press the button marked NEXT for further menu options Menus 04 07 ident bar and audio alarm accept Press NEXT PREV to navigate Menu Num Heading Automation Function 4 Ident a Pressing this will turn on or off the efault is On Bar Ident Bar Ident Lad The fade level of the Ident bar overlaid efault is 100 yp a on to the video i Arete veo mas 6 _ Notused used Accept nene E this accepts the current alarm alarm 12 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0
18. s half and Full 18 Audio i RG This sets the horizontal position of the H posn Audio bar on the video image 19 Audio dn oi This sets the vertical position of the V posn Audio bar on the video image Menus 20 23 Fader bar graph size and position Press NEXT PREV to navigate Menu Num Heading Automation Function 20 Fader acai _ The width of the Fader bar Width 21 Fader re The length of the Fader bar The size 2 full following options are available 1 4 Ve Default is 1 4 and Full 22 Fader un eae This sets the horizontal position of the H posn Fader bar on the video image 23 Fader San This sets the vertical position of the V posn Fader bar on the video image 14 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com Menus 24 27 Pan bar graph size and position Press NEXT PREV to navigate Menu Num Heading Automation Function 24 Pan a E The width of the Pan bar Width 25 Pan w The length of the Pan bar The size 2 ful following options are available 1 4 1 2 Default is 1 4 and Full 26 Pan An ee This sets the horizontal position of the H posn Fader bar on the video image 27 Pan ete A This sets the vertical position of the V posn Fader bar on the video image Menus 28 31 Edit ldent bar information Press NEXT PREV to navigate
19. the audio description control track is valid status OK e Displays status of audio description level PPM bar graph fade information vertical bar graph and pan information horizontal bar graph on screen e A status text banner is also overlayed on the screen showing absent OK Swapped Inverted and Swapped and Inverted Where Absent indicates no audio description control data Swapped indicates the control data on the left channel OK Inverted and Swapped and inverted being self evident In addition to these messages if a CRC error occurs the unit will also display CRC er Sw CRC InvCRC and S ICRO to indicate both the CRC error and the audio status e The user can define a 6 digit channel Ident definable in foreground colour background colour flashing or normal mode e The unit provides physical relay closures to give hardware outputs of the alarms and inputs GPl s to reset the alarms e All messages can be user defined in foreground colour background colour flashing or normal mode and whether that condition triggers an alarm e The main alert alarms can be accepted by the operator setting a second indication alarm which is cleared when the problem is completely resolved e The module broadcasts information compatible with the MD 2 Master Display module enabling collation of any unit s displays and allowing for remote Supervision dn
20. ting Panels to the AD 2 AD 2E The AD 2 AD 2E may be operated using a FP 9 Flexipanel locally mounted For a more operational environment the AD 2 AD 2E may be supplied with a desk mounting FP 10 or remotely sited FP 9 For detailed information on connecting remote panels refer to the section Connection of Remote Panels to a flexiBox in the geNETics Hardware Installation Guide Below is shown a typical system consisting of an AD 2 AD 2E in a flexiBox controlled by a remotely mounted FP 9 9 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com Connect Pins 1 2 4 7 9 from chassis to panels 1 1 Use twisted pair AES Digital Audio cable for pins 2 and 7 Pins 1 4 9 carry power 0 5 Amp 13V Use cable with a least a 1 amp rating for pins 1 4 9 Cable llength should not exceed 250m l Bus pins 2 amp 7 The I BUS Network requires terminating with 100 Ohms at each extreme end of the network Ensure that this is done either by an external 100 ohm resistor OR ONE Panel Product at each end has the termination set See the Genetics User Guide Under the sections Flexipanel Power l BUS Jumpers For the 4RU Panels see 4RU Panel FP 10 Jumpers for I BUS and 4RU Panel VP 10 SW 10 AP 10 Jumpers for I BUS Alternatively The termination can be set on a Product ie the AD

Download Pdf Manuals