Home
3 shape - Wieland Dental
Contents
1. Otherwise select the created order from the list and start ScanItImpression by clicking Next or Scan button in the Main toolbar or right clicking on the order and selecting Next or Scan from the right click menu gD NA On starting ScanItImpression the order in the list changes its icon to locked for scanning ke ak 1000_20090708_1116 Tech 7 8 200 7 8 2009 Scanning Crown 27 28 Zirkon ScanItImpression window opens asking you to insert your impression with the preparation side up 1 Main toolbar rT 8 P ht rv Aen Lene lire A0 18 1407 The A o Cire 28 i STE The at Hu np hp Fic View Hep x 2 dE d d 2 Visualization toolbar Insert Impression with 3 Model visibility preparation side up 4 2D cross section 5 Show undercuts 6 Show low quality areas 7 Manipulation toolbar 3shape Show low quality areas button can be used to validate the accuracy of the scan if important areas are of a low quality the impression should be visually compared to the scan After scanning has been completed successfully the orders change their status from Created to Scanned as illustrated below in the DentalManager order list ATARA rer ol 34 2 Deder s in Ibon ec A Le ze o nb em Creation Za le A dale Desire y dei Cent herr La Ee Lal State ESO Ty ey date PH 00005081427 Tech Op AAA 10008 d Boton Lab Gang Ay Den we Dro Modeled 64mm tes ing emm Ian Tech ER ie
2. eno 50400 EI as ama fl mm OK At the next step draw a line to cut preparation before alignment Click OK when done A8 Please cut preparation m before alignment E Ei D S e cae tl e Sec E E we F DW SP A SE Get porta ores by one o dq ahia n pn e BS Lg Je 3shape Then you are asked to insert the impression with antagonist side up click Next to start scanning Select the region of interest in antagonist and click Continue RATATE O At the next step draw a line to cut antagonist before alignment E Ela Ten bp A8 Please cut antagonist before alignment Hin ex OG rte 3 D I a ch At the next step you should align the preparation with the antagonist by placing the corresponding points on both models in the places of their contact For your convenience the colors and numbers of points on the preparation correspond to the colors and numbers of points on the antagonist You can place from 3 to 10 contact points on each model Click Align to perform the alignment Eie em e AW Align single tray A impressions Ki t D al El E E rn w ri gt ar aml aa 3shape gt The antagonist can be translated and rotated with the buttons on the Nudge toolbar or with the trans box rotation points as shown on the image below Possible collisions can be indicated when the Show check box is selected If you are not satisfied with the resul
3. The image below illustrates the final stage of the antagonist bite scanning 3 2 15 Antagonist Model In this example you will see how to scan a bridge model with antagonist Using DentalManager create a new order and make necessary settings for a bridge with antagonist in the Order Form Having completed defining a new order click Scan button to proceed to the scanning step This opens ScanItRestoration window asking you to insert preparation arch Previously created orders can be sent to scanning with the Next or Scan options available from the right click menu on one of the created orders listed within DentalManager Click Next button to scan preparation arch T 1 l i i ER lane ba EA RA LA EEA ELN HS TR DE TIA A E ee Insert preparation arch Fron sido Faces ihe inside of fhe SESRABF m CER EOC serpente pogani Ful arch a 3shape Once initial scanning is done select the area on the scanned arch for a detailed scan with the available tools and click Continue button ii E DN E E At the next step you mark teeth in the detailed scan accordingly then click OK button to continue DUT The next step requires you to replace preparation arch with antagonist arch in the scanner Click Next to perform scanning of antagonist arch D Hee insert antagonist arch j a Fr rf Aas faced had itty OF bra z Lonner Ki EI a Tus o K si 8 a o
4. DentalManager Ems 2010 03 16 Points in dangle a Paints ih wee I Points available 2 Chent Pica Connectors W Done e E tees Protected Mode Or ET The Inbox add on module supports multiple FTP servers ee geng for high load centralised production The functionality b 4 Modules and Add ons requires correct FTP settings at the orders sending sites and NS properly configured FTP server at the orders receiving sites a Pare paisti Che add on ard opins that should pp on Sher Pneuen There is no need for the FTP server to run on the same PC with the DentalManager Inbox Add on module d Ir The DentalManager Inbox Add on module fetches orders to the FTP server using the FTP protocol At least one account needs to be created on the FTP server with full control permissions since the data in the FTP account is going to be manipulated with created read modified and deleted Optio When licensed the Inbox Add on module can be enabled via the Options menu Label Printer Settings Module and add ons 2 6 1 Sending Orders from the Lab The orders created by the labs can be sent to the Inbox from where they are taken by manufacturers for production The setup process is described in Sites chapter of Dental System Control Panel section of the manual This section describes how to actually send orders to the Inbox Run 3Shape DentalManager select Orders tab and right click the desired order from available with the sc
5. Navigation Home Tasks Site Settings w Sites aff Manufacturing processes by Materials ey Operators Y Countries Ka Sites C Manufacturing processes Import Export NA Materials apj Import materials ME Export materials Countries The import and export of the material settings is now possible in Dental System Control Panel This new functionality provides an easy exchange of materials between the lab and the manufacturer You can export materials to the specified file or FTP by selecting the desired materials and clicking the Export to File or Export to FTP buttons Select the Lock exported materials check box in case the material settings must not be changed at the receiving end When you select the Always overwrite materials with the same IDs and Delete pre existing items in destination materials check boxes the warning dialog windows pop up to make sure that this is what you want to do bajo Ais d ANTOI Panel Ge i oF Le Save i on Navagation amp TEESE EEA a E a a O H E O O0 Ee i O O O O D SS e e e e e e e e e sp e e eech E e er S E L Aha ae Overanite materials with the same IDs mportna ale MES e eil P destination To import the material settings click on Import matertals and select the desired folder You can also download the materials directly from FTP go to Site Settings gt Sites and click Download Then select the m
6. When the Undercut removal button is selected it is only enabled when Remove undercuts in the Settings group is checked the color map displays the amount of undercut removal performed When the Drill compensation button is selected it is only enabled when Drill compensation is checked in the Settings group the color map displays the amount of drill compensation performed The Depth value shows the offset when you move the mouse cursor over the item The properties of the die interface are specified under Advanced Settings Extra cement gap Dist to margin line 1 00 ep Smooth dist Drill radius Drill Comp Offset 0 66 E mm 2 os F Cement gap 1 is the amount of offset in the area of the margin line Extra cement gap 2 is the amount of offset in the upper part of the interface Dist to margin line 3 is the distance from the margin line to the borderline marking the border between the cement gap and the extra cement gap offsets Smooth dist 4 is the area around the borderline in which the interface is smoothed This ensures a smooth transition between the two parts of the interface having different offsets Drill radius is the radius of the spherical drill tool applied only relevant when applying milling machines in the production step Drill Comp offset is the distance from the margin line that defines where the drill radius is applied Click Apply to view the result click OK to complete
7. directory Auto save interval SI The DentalDesigner tab should now have correctly set location if the step was completed successfully DentalDesigner 2008 legacy version is currently defined as El Use auto save during modelling a Use AddRemove Intelligent component in Dentalbesigner M Use Parametric Abutment Generation tool To enable automatic saving of the open order check the Use auto save during modelling check box and specify saving intervals If the Force validation on save check box is checked then DentalDesigner forces the Validation form to be shown at the end of the modelling in order to verify that the specified parameters coping thickness etc are satisfied The AddRemove Intelligent Component checkbox is selected by default allowing the use of the advanced Add Remove function in DentalDesigner The improvements concern the revised processing algorithm and increased speed Select the Use Parametric Abutment Generation tool to activate the new abutment tool in DentalDesigner see Customized Abutments chapter for more details e ScanlItRestoration e ScanltLibrar Ss It y The locations for these applications are specified the same way as for canitimpression DentalDesigner see above e DentalManager e 3D Viewer 3Shape Dongle Service shape Dongl 3S5hape Dongle Service Service status The service is installed and running on this PC Computer name or IP l Dongle service port 27027 E BR Op
8. Click Next button to scan preparation arch tA eure IBER ao 5 Once the initial scanning is done select the area on the scanned arch for a detailed scan with the available tools and click Continue button 0700 sauna OOS Detailed scan of the marked area is performed The next step requires you to remove pre preparation arch and place preparation arch in the scanner Click Next to perform scanning of the preparation arch Ce m 7 insert preparation arch Front eto fatet the inside of ihe annir Forte CEG amp po Pht UE On completion of the initial scanning select area for a detailed scan with available tools and click Continue button am F F gA Ai E KKK At the next step you need to align pre preparation arch using either one or 3 pont alignment method by placing corresponding points accordingly Align pre preparation SA entre sopaga 3shape gt You can select model with the cursor and rotate it in a desired direction with transbox points Click OK button to complete alignment D EI An T EI ka bori alc p biliar Point to mark corresponding teeth accordingly at the next step and click OK button Scanning and Saving finished Cikk op berber bead wai chew Ti mda ni ican eran Ee 3shape Examples of preparation and pre preparation scans trimming steps are shown below Exampl
9. Intersection Length 2 15 mm Show plane To modify connectors which DentalDesigner created automatically click on connectors in the modelling window or in the Overview toolbar You will get the Connector Settings window in the Tool Forms see the image to the right DentalDesigner automatically defines the shape of the connector using the default shape set in the Dental System Control Panel But you can change the shape by selecting a new one from the Connector Settings drop down menu Silhouette Circular etc The connectors shape can be defined in different ways using either the graphical interface or the components in the Values tab By changing the Center shift back value you can adjust the scaling of the centre of a connector By adjusting the Center scale value you can move the centre of a connector back and forward You can achieve both by inserting the necessary numbers in the fields or by manually dragging the connectors with a mouse All the changes are immediately reflected in the modelling window You can also make changes directly from there Click on the blue control points or and on the big central points one on each tooth to move them as desired At this stage a special modifying window appears displaying the connectors shape for both teeth as well as the 2D view of the connector Li e Ty rite Cira You can modify connectors directly from here click on the blue control points and drag the
10. Material Cement spaces Coping overlays Other than ID Name Material and Color this subcategory contains Cement spaces and Coping overlays Left click on them to get the corresponding settings For information on Cement spaces please see Anatomy Elements chapter When you click on Coping overlays the following window opens up Edit Coping overlay ID Configuration 11 IDCopingOverlayzro2 Change ID Mame Zircon Coping charter Material Wall height 1 500 ou Anatomical offset 0 900 a mm Remove undercuts Moe Le Overlays Wall height is the distance from the margin line to the borderline marking the beginning of an area where the wall thickness is applied When you click on Overlays there appears an Edit Overlay window the settings of which are described in Coping section of the Single Coping chapter Frame Pontics The settings are the same as for the Crowns Edit Crown subcategory in the Anatomy Elements chapter Waxups This subcategory contains two tabs Cement spaces and Waxup overlays Click on them to get the corresponding Change ID settings Wax Lip Zr zirkon Mot specified gt R R The information on Cement spaces is located in chapter Anatomy Elements Cement Space When you click on Waxup overlays there appears a window similar to the one below Cut offset is the offset distance from the margin line where the wax up scan is cut AAA and a smooth surface from the cut to the
11. Scanners See Scanner selection Advanced settings Current scanner File size of die scans including dies in a bridge This computer ip address 192 168 170 22 UPCO9 8 e Smallest Medium Largest Add scanner Eo list E Die scanning optimized For Remove current scanner From list Remowe qap Details Always scan Full arch Scanners Fill in your scanner s name location in the Add scanner to list field click Add to save or select the required scanner from the Current scanner drop down menu Click Remove to remove the current scanner from the list Advanced File size of die scans slide bar defines the number of points in the model The smaller amount of points selected leads to a smaller file size and a less accurate model while the larger one to a bigger file size and a more accurate model Die scanning optimized for slide bar is used when scanning separate dies only If you choose Details the scanned model will be of high quality but the scanning process will be very slow If Speed is selected then the scanning process will be fast resulting in a good model quality Always scan full arch when checked the program requires only a detailed scanning of a full arch when it is not checked both an overview and detailed scans are required 4 Scanning Impressions ScanItImpression The ScanItImpression add on module is started from DentalManager and allows producing digital models directly from impressions When configured
12. try ab 3 de Ai cb meaty 1h e shape KK ak Eat Le Seet es a mm Next you are prompted to mark the region of interest ct as shown on the image below This is the region containing all preparations and any desired adjacent TI teeth Click Continue when done D E ia y By o F E You will be asked to flip the fixture with the antagonist facing up Be careful not to move the impression within the fixture A8 Flip the fixture so the mm antagonist faces up Ki The impression must F not move within the t fixture D tEJ G 35 Scanning complete All models have been Click Net to proceed io virial model dns gn Ja expr Bogas sl AA When clicked the Corrections optional button expands to B Rescan preparation side de Corrections optional Ch Remove Artefacts Click Next to go to the Virtual Model Design step and do trimming to the model and antagonist 4 4 6 Virtual Model Design Once the trimming of the model and antagonist has been performed click OK to continue Virtual Model Design es Stop 2 of 4 Thm antagonist Ki a CS E ota a Ka r H Info Al Ch porn one by one of day me haing he etmon rhi cio Kack ed Show oppose ja probe a gt 6 The Add Remove material stage is an optional stage that can be used to modify the impression e g correct flaws in the preparation or remove gum tissue The next virt
13. 37 PM oth iD Model File 106 E pictures Pos 20099900 1437 Tech DL La MADE 2 37 PM STL ID Model File E H Musie More Y Folden de 41000_ 00905 4_1422 e Ji dmi 20t t64 148 Tech DI Bleck de Bel 20090908 1870 Petersen J Etan 0090908 124 Teeh 0l Ji Foie 20090914 1543 Tech A4 Sore Le Ext4405_20090915_1714 Tech 01 A Fa pig 200909131754 Tech 0l de Inbox L ManufectanngDir de 20135 20000439 1005 Tech DI Li 20135 20090819 1417 Tech 01 Di 20135 20066819 1435 Tech DI de 20135 20091919 1452 Tech 01 Lo 20090508_1427_Tech_01 ha 20090918 1512 Tech oa E m d ems Material Orders that have status Scanned or Modeled can be sent to a remote manufacturer milling center using DentalManager To do so you have to Manufacturing process Milling RO mr specify the Manufacturer in the Order form see the image to the left Manufacturer Johnson Milling a TT You can Add Edit Delete manufactures in Dental System Control Panel DSCP gt Site Settings gt Sites Color Al To add a manufacturer in Dental System Control Panel click on WP rile type in the Name and FTP IP address and check the Has CAM check box LIES S24 You have to specify also the Manufacturing process in the Order Form see the image above To Add Edit Delete manufacturing process go to Dental System Control DSCP gt Site Settings gt Manufacturing process It is important that the manufacturer you created and specified in Order form in o
14. A ea ett Te A Se Namen WW bom Lae iaid Cent gedet riei i bal ANA ban OLA rA DI pt MINA TAI Lie ei s E e Arsch Ae A VP pp eg A 18 tech PI D CHA vumm UVA Sure Tira ead mon Mirar sa a men An men Aa ga TER vw AEN Late pre ege Mee RT J E i 7 Ke e i Da 2100 meman asan Jach 1 Pei d HE wm ALEN Bardin ia brig mam inmid Laima gn COTATI aoada 1009 rrn ee wa Nr Spent Ces A pp Dr Gremie Braun mme Va Ir 21 Se ee Arem L t ed Gel PDF on mmer b ckt 31 pel LEE pr KWR EEN sede Cereal i ihe Aen Tamni Li Mo m0 L nu KI LAN Lett ge AAA rar ET l Oe 11 iP Bech Dt LW VIC a o ae ae Cong 2 DE warned E P i re a a 1380 Tech Dt Bach BOND Ce li lz rem pre Poincar ui enced ee rire i Wires Few ste MUNO ae Hiro pri Hi Ree P HF pal sshape gt 2 5 2 Generate CAM Output LE ve ay Claie A e E Madify A Pe Model FP Check Out A 10 Previa A Delete ah Pefrerh Tend Sale ct En ig rt Carlet Cul h Ctrl edit O Cer al L W Print Feet Esport To Fie Gleck Export To FTP Cola Export To Mal Ctrl el Export FRP File Cul Bl Expl re Orden Explore CA hited Genera LAM Cutput Fi Depending on the purchase conditions 3Shape Dental System s output can be used with any third party rapid prototyping milling machines which accepts STL files as input please contact your local 3Shape dealer for more details Usually 3Shape Dental System is bundled as OEM component along wit
15. A eed A este Sa wegen Ta en e e STT ep m mie E L ao WEE a a UE UN NA Teme e Te cds e re Dere Fan 4 JERIA Teh KI anran a 6 5 d E MH Tee BI io a Ps iH la TL n brema A ii tie ot LE hae a z est A Te Ol teg ETLI Aa Zeng Cem Case 2 Brar E Ce EC Sea E e a ei ef Jee tiS kab Uu Er ecto dr Shei Foii mm Ps ett ashape The Main Toolbar includes Buttons of the workflow process that can change depending on the order and the stage of the process Buttons that bring you to a particular 3Shape program or application and are shown at any stage Order Filter orders in DentalManager can be sorted searched and displayed by the following categories Date Status and Other For example if you want to find the orders that have been created last week or that are scanned click on the corresponding filters Orders the orders you are working with and the ones that are stored under the selected category Date Status and Other are displayed in this window When you create a new order it appears in the list of orders automatically showing information about its Creation date Material etc You can also see the single units of an order and get information about each of them separately see the image below This option is very helpful when it comes to production as well as pricing invoicing accounting etc Use the Orders Items button in the Main toolbar to expand collapse orders or display order items only The
16. Change 1D margin line automatically generated Waxup overlay Zr Zirkon 2 000 Lar 0 000 e rl Waxup offset is the wax up surface offset outwards positive or inwards negative When you click on Overlays see the image to the left Edit Overlay window appears described in this chapter above in Copings subcategory See also Coping section of the Single Coping chapter for more details 6 3 4 Primary Telescopes Primary telescopes category identifies the material bound primary telescope construction element Click Primary telescopes to get the window shown on the image below change ID Primary telescope crown Zr Not specified R R Edit Primary telescope window contains three tabs Cement spaces Telescope overlays and Optional components The information on Cement spaces is located in Anatomy Elements chapter Click Telescope overlays to open the following settings Edit Telescope overlay ID Configuration_11_TelescopeOverlay1 Change ID Mame Telescope overlay Zr Material Wall height 1 000 ou Telescope angle Telescope smooth 13 Telescope default height 23 00 fo Telescope border margin line shaped Overlays Wall height is the distance from the margin line to the borderline marking the beginning of the area where the wall thickness is applied Telescope angle is the angle of the telescope cone measured from the telescope direction Telescope smooth is the factor
17. Change ID Name Miling BO Arm i Manufacturing process method CADOutputRawsSTL dll Miling Additional miling information dh Add Drill compensation ja Copy Drill compensation offset 0 660 W A Delete D Move up ay Move down Brill radius 0 650 fla Materials Manufacturers zirkon Johnson Milling Titan Bradford Milling em No items Wax ES Restore all items Ey Empty the Recycle Bin Recycle bin Details Total 2 items Caution Changing the provided settings can have a significant effect on the quality of the manufactured construction elements Please contact your distributor prior to making any changes The Manufacturing process combines manufacturing with the available manufacturers as specified in Sites section and materials as specified in Materials section As seen from the image you can specify a manufacturer for a particular manufacturing process and the materials for this process These settings are then reflected in the order form 6 4 5 Operators Operators settings identify the users of the 3Shape Dental System applications These operators can be chosen in the Order Form and optionally the names of the operators can be part of the order ID You can modify the Operator list add delete etc at any time Operator Edit Operator Tech O1 ID Configuration_11_ IDCperator01 Change ID Name Tech 01 6 5 DentalManager DentalManager category contains settings for customizing 3Shape Dent
18. Cleaning old system Ire ain er n retira cele Creating customizations Menging materials nealing ahs Downloading materias form sites LOGAN o Chef LILLS d Irrel alent wbrarg af Copying documentation Finakzing satup m r a d EJ d y d Y y an Fol j Contirm E d D ed E E a Kg d La ves Ho d T d D d d d The process may take several minutes In the upper left corner of the window you can see the installation procedure step by step with the current step being highlighted in bold see the image above In the right part of the window the installed applications are displayed Select the Open What s New PDF check box to view the document with the new features in 3Shape Dental System 2009 If the material item that exists in the local material file is different from what is provided in the Installer the Update materials window see below pops up offering you to update recommended or keep the existing item values The item Validation Configuration 11 Validation1 already exists in the local material file but with different values Advanced Existing material ID Configuration _11_Validation1 Mame validation Description Connector rea 7 0000 Connectorstrength 0 0000 WallThickness 0 4500 DistFromMarginLine 1 0000 WriteProtected False ForceMinThicknessLevel fmtlCheckaAllowetjolation MateriallD Configuration_11_Materiall ValidateConnector4rea True d alid ateconnectorstren gth i False
19. Line described in Single Coping chapter Correct placement of the margin line for Post amp Core is illustrated on the image Die Interface This stage is identical to Die Interface described in Single Coping chapter Crown This stage is identical to Crown described in Full Anatomical Crown chapter COPING This stage is identical to Coping described in Single Coping chapter The result of Post amp Core modeling in DentalDesigner is shown on the image Sculpt This stage is identical to Scu pt described in Single Coping chapter 5 2 2 15 Digital Wax Up Bridge The digital wax up bridge combines the advanced design options of the normal bridge modelling with the easy design associated with the standard wax up bridge Utilizing the new advanced possibilities for modelling the anatomy bridge framework you can design the anatomy as desired When the anatomy design is completed the frame layer is easily created using the existing Wax up bridge functionality of the designed anatomy bridge Finally the entire frame layer can be finalized using the advanced sculpt functionality 5 2 2 16 Bar The Edit bar stage allows you to easily model complex bar structures insuring a high level of precision and parallelism The option to edit the shape of the bar for the customized bridge e g abutment or telescope is provided in order to improve and refine the design of the bar according to the anatomical shapes of the preparation surface and
20. Panel Material Settings section or defined manually in the Validation dialog and marks the areas needing attention with red exclamation marks whereas successfully validated parameters are marked with green ticks Click on the exclamation mark to get a description of a problem In order to run the validation process click Validation 3 button in the Visualization toolbar of DentalDesigner to compare the model values with the predefined ones The Validation dialog box appears in the right upper corner of the modelling window see image to the left The Validation parameters Thickness Area Strength can be set to match your particular case Click Update to update each time the parameters are changed unless Update Automatically check box is selected Select Apply Material Settings check box to apply the material settings from Dental System Control Panel Dental System Control Panel 3Shape Dental System Control Panel is an application that enables you to customize the necessary settings to get a fully satisfying performance from the 3Shape Dental System applications Dental System Control Panel is started by double clicking the corresponding icon either from DentalManager or from the desktop The image below illustrates the main window of Dental System Control Panel and its categories de Dente Bestoen Cortrol m4 kl Save GA Bach i Der oaltieAhprer d dd eral eee d 30 Visper Dongle Levene Server Order Directo
21. The images below illustrate the initial model and the final result of the Design abutments step see sections below for more information Parametric Gs At the Parametric step you can select the desired library Anatomical Artificial etc ings Library Top cap and Margin slide bars help you shape the top cap and the margin line of the abutment respectively You can choose either the rectangle or the triangle shape for this E A purpose Top Cap F Hole is the diameter of the abutment hole Margin F 8 Grid is the size of the grid that appears when you place the cursor over the orange y L d a DH 2 a es control points and the size of the arrows that appear when you place a cursor over the Chamfer KEE blue control points Vertical offset 0 00 o l SE A Chamfer is lofting of the surface between the margin line and the top cap spline wola Vertical offset is the distance from the bottom of the abutment where the offset is applied Retention groove when checked creates a groove in the abutment to prevent the crown from rotating on a round abutment The following buttons can be activated to show hide some of the objects features on the abutment Hides top cap Shows distance color map Shows Hides abutment screw hole Shows Hides implant direction cylinder Shows Hides undercuts eje lelea Sculpt This stage is identical to Sculpt described in Single Coping chapter Assembly The Ass
22. and Accept All Accept Selected Orders window appears when clicking the Accept button There you can choose whether to create a CAM file at this time as well When Create CAM files now is checked the CAM files are automatically created when the order is accepted Accept the selected order s for manufacturing Expected common delivery date 10 1 2009 foe M Create CAM files now Pass this message back to the client The order has been accepted for production Le Once the order is accepted it is removed from the Inbox list and appears under the Orders tab with the status Accepted 20105 20090819_ 1062 Ze 01 AAS ASES ahanon 2 19 2009 Eme Deras Wan 3 Trige Modeled 5 Eine aan mua Let teen ZE SEE phones Women Sunny Cirit VER Son scared o BB e _20040804_ 1433 EE eT aac rite Sree mana bridle trian came e Ey ven mn magie ZE aoo MOR rees WE z Dm UNO RIAN Am Dana AO LLI Peterson ti 9 14 2009 0 13 2005 Gar Cree Anat bidja Wir Dion emed A i D EH i A Eo mea Du Teh DI Se DT wem E Code Tirra AM We Then Mehlen L mar W 20090914_1549_Tech Dl Sorensen NA aa 2009 9 14 2005 Ems Deran e a cone el i Se 0 15 2004 Mos 20030915 ta Ten DI ar 9 15 2009 4 15 2009 Johraon M ng Abutment 9 iran kaei 0795 2009 E Mco 20000015 1755 ey DI SE TEE 0 15 2000 Eed Derial Copan 1 Scheer Scanned The order is now received by the manufacturer and depending on its state it can be modeled or take
23. below illustrates the main window of this tab Dental System Control Panel Bar lH Save E Back Navigation Home Material Settings 5 Edit Bar Ellipse Dolder Change ID Rectangle Rectangle Custom wl coordinate Y coordinate a 1 00 0 00 0 50 0 00 0 00 0 00 0 50 0 00 qP 1 00 0 00 1 00 1 00 1 00 2 00 e x By 1 008 e E 0006121822430 AAA a LEAR if aale e dll dal al gt H E JK WE EIS me ei 3 1 3 7 4 3 4 5 Total 3 items 55 0 60 d 1 00 d 0 50 d 0 50 d Bar shape type is a descriptive type of a bar shape Currently five types are supported Custom Circular Elliptical Dolder and Trapezoid The Circular Elliptical Dolder and Trapezoid bar shape types provide additional settings specifying the number of points width height and angle of the bar For the Custom bar shape data interface provides the possibility of both typing the coordinates in the Shape spline window and drawing in the Shape spline image grid Shape spline image grid spacing defines the grid size used when drawing the bar shape Distance to spline defines the distance between the placement overview spline and the top of the bar see the image below Distance to gingiva defines the distance between the lower part of the bar and the gingiva Tooth elements gap radius defines the radius of the gap at the intersection between the bar and the construction element see the image below 1 Dis
24. changed Delivery date Shipping date Receive date Clinic order na De iver y ty pe Y a a D D GD D DD DG D Ship to different acess Patient information Last name First name WD D D Reference a Comments Order settings Order number External order number E ee Order importance You can also define a naming template for the identification of each order This identification will be the name of both the order data folder and the production data folder The template consists of up to 8 fields each specifying a substring in the name in the chosen sequential order Please see chapter Order Settings for more information If Use internal ID for order ID generation is checked then the SiteID may be chosen differently from the actual SiteID Define template for order ID generation Lise internal ID for order 10 generation Crder ID template field 1 Siteld using MIS characters where spacing strinc Crder ID template field 2 Date using characters where spacing strinc Crder ID template field 3 Time using MS characters where spacing strinc Crder ID template field Operator using characters where spacing strinc Crder ID template field 5 Dentist e using characters where spacing strinc Crder ID template field 6 Patient last name using characters where spacing string Crder I0 template field Unspecified using MIS characters where spacing strine Crder ID template field 8 Unspecified e using A
25. dental system solutions WIELAND embodies both tradition and progress in matters of dental products and technology Since our company was founded in 1871 we have stayed true to our corporate philosophy of combining tradition innovation and quality with the best in customer care Today our core competencies and key strengths lie in the forward looking integration of technologies and materials for dental prosthetics This ensures that patients can trust in the quality of their dentures and our partners in dental practices and laboratories can continue with confidence on the path to digitalisation and greater competitiveness WIELAND offers a wide range of products and services from CAD CAM technologies and dental alloys to veneering ceramics and electroforming Thanks to our worldwide presence and international network WIELAND is never far away and your contact person can always be located via the Internet www wieland international com WIELAND Dental Technik GmbH amp Co KG Schwenninger StraBe 13 75179 Pforzheim Germany Fon 49 72 31 37 05 0 Fax 49 72 31 3579 59 535056e 00 02 10
26. determining the smoothing of the top surface according to the underlying coping overlay surface Telescope default height is the height of the telescope cone Telescope border margin line shaped when checked the telescope border the top upper control points is initialized shaped as the margin line otherwise in a plane i e flat orthogonal to the telescope direction When you click Overlays see the previous image Edit Overlay window appears its settings are described in Coping section of the Single Coping chapter Click Optional components to get the following settings Edit Optional component ID Configuration_11_OptionalComponent 1 change 1D Optional component C Program Files 3Shape Cental System Control Panelibrary SShape Optional components telescope Thickness 1 stl The Optional Components tab can only be accessed from Primary Telescope category since only primary telescope construction elements can have components attached on the sides The Optional Component settings include a path to a closed model in the STL format The default Optional Component item is linked to a 3Shape library component The path can be changed with a click on the path name see the image above to open a file browser It is possible to create and use customized components but some guidelines must be followed Please contact 3Shape for further information 6 3 5 Abutments 3Shape Dental System is an open system where all Abutments kin
27. die will rotate so that the next point can be placed by pressing the left mouse button once again A spline appears between the points during the placement After you make a full circle and click on the first point the spline is automatically closed Ca gt t Ce e Order Frame bridge 2 4 Clinic Sunny Clinic Using Edit points 1 This tool is active when the Keyboard button is selected 2 Click on the blue arrows to move from point to point and to move the points up and down not need to be placed exactly on the margin line A detailed definition of this line is performed at Interfaces step of the modelling process Note The green points only reflect an estimate of the margin line hence they do Invertir Ir When the points are positioned correctly on all items in the restoration click Done and an optimization procedure will automatically provide an estimate of the insertion direction The current restoration is rotated into a position proposing this direction as the user point of view as visualized in the image on the left You can always rotate the die and press the Set button to redefine the current point of view as the insertion direction The direction can also be changed by clicking the blue arrows A in the Tool Forms To increase or decrease the angle of direction positioning set up the desired angle in the Step box by choosing the corresponding number and then click on arrows In addition the
28. followed by one of the numbers to store the current tool settings This allows you to go back to any of them later on by simply pressing the number Ti The last tool is Operations and parameters LN By clicking on one of the LO buttons you let it automatically smooth e the entire surface of the model enforce minimum thickness or and cut the model to antagonist You can specify the minimum thickness and the desired distance to the antagonist If you are working with a pontic the desired distance to gingiva can be specified Enforce minimum thickness functionality in the process of modelling a restoration you can accidentally violate the minimum thickness This can be easily fixed though by clicking the Enforce minimum thickness button which will automatically set the necessary thickness and correct your mistake If the minimum thickness was not violated or has been already fixed after clicking the button you will get the following message The desired minimum thickness is already met This functionality also takes action when you move to the next step and the minimum thickness criterion is not met In this case you get a waning as illustrated below suggesting you the automatic enforcement of the minimum thickness Warning i Crown 30 violates the minimum material wall thickness of 0 91 mm Would you like to enforce the minimum thickness To disable this check change the validation enforcement policy for the current
29. is now complete and the model has been saved The final models from the virtual model design are automatically saved in the order folder in the Virtual Trimming subfolder If you would like to start the modeling process in DentalDesigner click the Design button 4 4 3 Antagonist Single Tray Scan settings e i S Before scanning an impression with the antagonist define your order in Object type the Order form Select Impression as an object type and Single tray for Pater ERTS the antagonist Click OK to save your order which will appear in the a DentalManager order list with the status Created ace Scan None You can also start ScanItImpression directly from the Order form by clicking the Scan button Otherwise select the created order from the DentalManager order list and start ScanItImpression by clicking Next or Scan When the program opens insert the impression model into the scanner and click Insert Impression with Se Next button to initiate the scanning process preparation side up A fast overview scan is performed and appears on the screen shortly The application asks you to mark the teeth included in your order Select each preparation individually and click Continue after each one DOG ep 0 FN 3shape gt Next you are prompted to mark the region of interest as shown on the image below This is the region containing all preparations and any desired adjacent teeth Click Continue when done
30. material in the Dental System Control Panel Click OK to end the process of using Sculpt toolkit Click Next to move to Finalize step 5 2 2 2 Bridge Framework Annotations This stage is identical to Annotations described in Single Coping chapter Insertion Direction This stage is identical to Insertion Direction described in Single Coping chapter Margin Line This stage is identical to Margin Line described in Single Coping chapter Die Interface This stage is identical to Die Interface described in Single Coping chapter Load Pontic Model POS To modify a pontic double click on it in the modelling window or in the Overview toolbar The Process toolbar will display two buttons Load pontic model and Sculpt Click on Load pontic model to load a pontic model from the library as shown on the image to the left The file name is automatically defined based on the current tooth Click Browse to look for more pontic templates The Pontic stage only loads the model while the following Sculpt stage transforms the pontic to the desired position and shape please see description of Sculpt in w ES Single Coping chapter Prismatik v1 0 Premium D di File name A CuProgram Filesi35hapelDental Sys Copings This stage is identical to Coping described in Single Coping chapter Edit Connector Connector Settings Graphic Occlusal view Heln mints Center shift back Center scale 0 00 E 0 85 Facial view
31. mesh button The area with poor triangulation will be highlighted in red color 5 4 Modeling Tools This section describes three modeling tools 2D Cross Section Window allows better inspection of the dental models Distance Measurements allow to perform Distance to Adjacent Distance to Preparation Scan and Distance to Antagonist Scan measurements Validation verification of the restoration model against the pre set values 5 4 1 2D Cross Section Window The 2D Cross section window allows better inspection of the dental Parallel View models 2D cross sections can be specified either by placing three points on a 3D model dragging a section line while holding down the left mouse button and moving the cursor across the model or with the Parallel Perpendicular View buttons in the 2D Cross Section Perpendicular View window To use the cross section window click the 2D Cross Section Clear View button in the Visualization toolbar in order to open the 2D Cross Left Clipping Plane Section window The window contains buttons with the functionality shown in the table to the left Right Clipping Plane Measure area Clear Measurement Zoom All Grid Perpendicular View example is shown below HE ig ul SS WW E W el Si e ASPAS Clear View the button clears image from the 2D Cross Section window Left Right Clipping Planes buttons allow to hide one of the cut halves examp
32. must have write access to both the order data directory and the production data directory The corresponding check boxes provide the possibility to organize the location of the manufacturing output files in different ways The Save DentalDesigner manufacturing output to separate directory checkbox specifies whether the manufacturing files should be placed in a sub folder named according to the order file or if the manufacturing files for all orders should all be placed in the same output folder The Save DentalDesigner manufacturing output to material named subdirectories checkbox gives the possibility to place all manufacturing files inside a folder named according to the selected material Order Form Settings In the Order Form Settings you can decide what Ke information should be visible or editable in the Order Form Check items to be visible and or enabled in the order Form and define order identification naming template visible Enabled For each information item you click the Visible check box to make the information visible on the Order Form and the Enabled check box to make it editable through the Order Form If a whole group of information e g Lab information is set to non visible the information items in that group i e Lab operator will all be invisible in the Order Form Lab information Lab operator Client information Client Contact person Sie Sie Note Some check boxes are disabled These are mandatory and cannot be
33. off check box becomes active Lift crown off when checked lifts the anatomy from the framework ill radius 0 65 Ah i 0 66 Fl Liner space Liner space 0 040 5 2 2 5 Anatomical Copings and Framework Annotations This stage is identical to Annotations described in Single Coping chapter Insertion Direction This stage is identical to Insertion Direction described in Single Coping chapter Margin Line This stage is identical to Margin Line described in Single Coping chapter Die Interface This stage is identical to Die Interface described in Single Coping chapter Load Pontic Model This stage is identical to Load Pontic Model described in Bridge Framework chapter Anatomical Coping This stage is identical to Anatomical Coping described in Single Coping chapter Edit Connector This stage is identical to Edit Connector described in Bridge Framework chapter Edit Bar This stage is identical to Edit Bar described in Bar chapter 5 2 2 6 Inlay Inlay Bridge Annotations This stage is identical to Annotations described in Single Coping chapter Insertion Direction This stage is identical to Insertion Direction described in Single Coping chapter Margin Line This stage is identical to Margin Line described in Single Coping chapter Die Interface This stage is identical to Die Interface described in Single Coping chapter The 3Shape Dental System fully supports the design of inlays onlays and veneers
34. offsetting the wax up inwards Lingual band The Wax up offset is the outer wax up surface offset parameter allowing to offset KK e i inn modelled wax ups inwards in order to make room for ceramics m 1 00 5 mm Resiralze actie cut spine D Ee Note A negative offset is applied inwards whereas a positive offset is applied outwards d P i The Cut offset is the distance between the margin line and the cut spline indicated by the green arrow The cut spline is used for cutting the scanned wax up the part above this spline is used when designing the wax up model The default placement of the cut spline can always be edited with the help of a Fast edit functionality which when activated lets you easily draw or click on the model for a quick and easy editing The rest of the settings Margin line offset Offset angle 1 Extension offset Start angle End angle Offset are similar to the Coping settings Sculpt This stage is identical to Sculpt described in Single Coping chapter 5 2 2 10 Wax Up Bridge Annotations This stage is identical to Annotations described in Single Coping chapter Insertion Direction This stage is identical to Insertion Direction described in Single Coping chapter Margin Line This stage is identical to Margin Line described in Single Coping chapter Die Interface This stage is identical to Die Interface described in Single Coping chapter Wax up Bridge Waxup bridge Copi
35. oo A 66 q nn E ET AA 159 ie ng eg Di Lu e POAT 159 IDO ele EE 27 A lo E E E 111 Inlay Inlay lg e e GE 14 39 111 Insertion Direction 112 eege EE 3 eebe 3 INTA OASIS os 22 ENTFOUCUON io 3 K Key DO le WEE 173 L Ea Dig EE EE 29 ADCS act E M tut E cm rare cata nnae T 26 tele EE 162 LID RAY EXPO EE 169 M He TOODA aa EEEE 92 Manal Eye Un e EE 23 Manufacturing Plenaria 23 Manta cua 19 ME A 156 159 AV Oe eee cr eae nun eae eeu ee 159 dee 156 Manufacturing Center Nee NENNEN 20 ManUfaclUninig E 23 Manual Handling EE 23 Margin De EE 97 110 Material Settings E 138 Materials ara 155 te NEE EEEE 162 ele e OR nl e EE 95 Mode IN ia 22 32 96 127 162 ale AA E E E 162 e o aa 22 SCANNING era 32 SEENEN 96 TODOS is cri cete een ase a 127 le e e NING SE EN Ord Te 21 Motion Controllers Support ccceeeeeeee eee eeeeeeeeaaees 174 O Oni le e EE EE 27 Onlay VWenNeerS NNN 14 39 112 OD SIA ONS iere e e ttn EEEE EADE 156 Eege 10 DAMA d ea 10 order Sens EE 20 Order te EE 97 Ode Sisi ri 9 21 22 23 25 29 Cosina 25 eg e Le E 9 le Te e e EE 25 le e gle eee emcee seen ee ge ener enc eee ene rt ire 22 lee eet EE 21 Remote Manutacturmng nn rra 23 Scan uretra e 21 SONCING scott IAS 29 OU aaa 27 Over pressed Crowns NNN 15 39 112 OVERVIEW TOO Dart 93 P PO SU aAA EAEE AEAT OT N ee a at 19 91 123 POsterior TAPIE TVs 86 Pre preparation SCA Mustaine 60 Primary Telescopes e 145 PRINT CONCERTS EEN 26 Proc
36. optimization can always be calculated again by pressing the Optimize button Two blue arrows display the calculated insertion direction The dark red shading indicates undercut areas for the given insertion direction see image below Undercuts are areas that need compensation during the modelling process and it is important that the area above the margin line is not part of the undercut area The undercuts can be measured by selecting Measure undercuts where the total undercut area as well as the depth of the undercuts is visualized Click OK to complete the process and move to the next step Interfaces d e Ee e Annotations Points x ges Edit points Keyboard Mouse Insertion direction ZS a Bl aj Sep 23 ei Loupe ei a Set Approximate height 8 99 mm Difference map Colonmg Undercut area gt Measure undercuts Order Frame bridge 2 4 OK Clinic Sms Clinic Undercut areas MARGIN LINE The aim of this stage is to define the exact margin line for the item being modelled The margin lines are defined for all dies before moving to the Die interface stage A well defined margin line is essential for obtaining a good final fit and hence this step is one of the most important steps in the entire modelling process This step only marks the margin line The actual cutting of the die is performed in the next modelling step A number of green points is automatically placed on the
37. person OPE Gta YIS pe fen SPO Oen bakon aped A 3 act ewe cave bh osos 150 tens A ayn 9 14 2009 tenio eta DEZ FT Sos Sued a Lit rvs E A LICE Tech P coma eM loaned 7 HEET PH E Last ovo weeks M 20105 200908191005 e OI Bf SO By Lan erg Clee Cum A Has zk Mode GF Ry 4 4 2009 2 43 Piet L ey eens 20135_20090019_1415_Tech_01 Bora Bra Sg rit Pumebidge ZA Wa frm Modeled S4 mmy 4 2 Preparing for Scanning Here are a couple of suggestions on how to prepare for the adaptive impression scanning in order to achieve good results 1 Trim the physical impression with a knife prior to scanning cutting away as much excessive material as possible This is very important because there can be a lot of impression material in irrelevant areas which would prevent the cameras from seeing into the impression 2 Before scanning apply scan powder to the impression using a brush or use a scan spray It is important that the spray powder is carefully applied over the entire impression as well as the tray aS uncovered areas may affect the overall result This procedure is highly recommended unless scanning a 3Shape approved impression material 4 3 Scan Settings Select File gt Scan Settings from the Main toolbar to modify settings for your particular case if necessary Save Keep raw scan data Save type Scanner selection Current scanner This computer e ip address 127 0 0 1 Add scanner to list Remove current scanne
38. the points on the spline can be moved using the keyboard e Press the RIGHT and LEFT arrow keys on the keyboard to change between the points each point is displayed as a green ball placed on a red line on the individual die e Press the UP and DOWN arrow keys on the keyboard to move the points up and down If a point needs to be moved a long distance and faster press Ctrl UP DOWN or Shift UP DOWN When the points are moved using keyboard the 2D Margin line window appears for a precise positioning of the individual points in the margin line When the Step button is not pressed you can move points with the mouse by clicking and dragging them Right click ona point and choose Remove to delete individual points and choose Add to create new points It is always possible to get a new estimate of the margin line by pressing the Recalc button and to clear the spline by pressing the Clear button The Point distance box defines the distance between each point on the automatically extracted spline The Angle is the angular difference between the margin direction see description below and the angle used in the red pencil margin line algorithm The Maintain angle slide bar defines the importance of the Angle value With a high value the angular difference described above is the important parameter in the margin line algorithm while lower values result in the local curvature of the die being more important in the margin line algorithm T
39. which lets you design single inlays onlays veneers and inlay bridges quickly and more accurately than possible with manual design methods During each phase of the design process DentalDesigner calculates and suggests the appropriate designs and selections The shape of the inlay onlay or veneer is automatically morphed to match the original anatomy of the treated tooth the proximal and antagonist surfaces Yet you can modify the suggested anatomy designs using the Sculpt toolkit When you proceed to the Anatomy design stage in DentalDesigner it automatically places inlays but you can always modify them as desired State A Create Modify Anatomy library A Meighbor contact points None 5 One a Two EC Advanced _ Adjust To Antagonist Cran n etance 1 ES secas 1 1 k Material settings Min thickness 0 4 amp mm Transition 0 5 E mm Click on Inlay in the Process toolbar to modify the inlay s When on the Inlay step place the red control points see image to the left on the relevant cusps Once placed on the cusps the points turn yellow Click the Create Modify button to initiate the anatomy morphing of the inlay After the morphing the blue control points appear on the inlay see image above and you can move and place them as desired Click Select Model button to load different inlay models out of the extended Anatomy library In addition you can click Browse to pick an arbitrary model Click
40. 1 2 ScanServer The 3Shape ScanServer application program works as a software driver to bridge the gap between the scanner hardware and the scanning applications e g ScanItRestoration Therefore its function is to provide a low level hardware communication with the scanner and to output the 3D pointcloud based on the scanner cameras input Whenever a scan is to be performed the ScanServer needs to be ON and ready for operation Connect your scanner to the PC using the USB cable USB Universal Serial Bus cables are standard data transmission cables The flat end of the cable is plugged into the computer the square end into the scanner The USB cable should be plugged into one of the rear ports of the computer Rear of the D700 1 Fan 2 Power switch 3 USB port 4 Power supply port Mo deseg complet eth Port 19 of the PC Bake Cpe p D st o Ve Feller iej e coed gier ii Eve eip red thee b s ieee ee deel ena A vee e aser lor i D u Em E E iamo i ei Ae Du leide NA mi DH re fan Y 3 F rl ca ba T She mail aert are init feed ee al Connect the power supply to the scanner power supply port and plug the power supply to the power outlet Use standard precaution when operating the scanner power supply Caution We strongly recommend that both the scanner power supply and scan server PC power cable are i plugged into a UPS unit rather than directly into the mains outlet to prevent work losses and damages to the e
41. 3Shape Default to use the default application Default design module lets you choose the application to be used for modelling DentalDesigner 2009 or DentalDesigner 2008 This option provides the possibility to use the well known DentalDesigner 2008 version but naturally it is recommended to use the 2009 version as this version is much improved in many ways with regards to new functionality as well as user friendliness Choose Use 3Shape Default to use the default application The Use colors check box when selected allows you to choose colors for your restoration in the Order from Validation enforcement policy can be very helpful during the modelling process pointing and or improving some of the violations of minimal parameters e g wall thickness You can choose here one of the four options No enforcement User can choose to ignore violations Always enforce but notify the user first Always enforce without notifying the user Specify the parameters for Minimum wall thickness connector area and strength active when the corresponding check box is selected Margin Line Specify here the default settings for detecting the margin line Point distance defines the distance between neighboring points on the margin line Edit Margin line Angle defines the angle used for automatic detection of the margin line Increasing this angle will make the automatically detected margin line crawl up on the die and vice versa for decreasing i
42. 43 e E Primary Kee 144 oooO EEN 145 6 3 0 Bridge EE 148 A e EEE A 150 Oral oE Srta ldad aan 152 SEL IMA Sade 154 0A G1 AAA A EE 154 6 44 Manta CUE E lee Ova 155 Odio Operators erneer erronea load alla lala e lidad dad seats 155 DentalManag Gr sisiraan a a aaa a a ada daaa a aaa aaia 156 6 Dil Generada AAA AAN 156 625 2 ERPand Processing MO ege enee ALA ED EDESA AA 157 e a NA iat an nehundS OO SS ABBR ROAR ARAN RROD ARAR ANAS KEE AEEA RE AE EEE Meee Anan EE ET 158 6 54 ManWitaccuirinG It OX EE 158 Scan hg Blo gre SANS IEEE AAE AAE EE E EA 159 Adding Model de MID Gary EE 160 EDF EXP lo eae eee ea ees eee oa li at 167 Appendix B Using Mous and KEY DOA oi AAA AAA AAA AAA iin thas di 172 With the 2009 version the 3Shape Dental System further builds upon its position as the leading CAD CAM solution on the market The system gives laboratories of any size the opportunity to offer the highest level of output quality improve their productivity and turnaround time and future proof their business Through an intuitive and user friendly interface users can scan and design an extensive list of supported restorative indications applicable for manufacturing in any suitable material or as determined by your 3Shape solution provider and or manufacturing facility Depending on the system configuration and software modules purchased and the model of 3Shape scanner utilized some functionality of the 3Shape Dental System may not be in
43. 73 4 4 3 Antagonist SInGle TT Vania A 76 40424 Virtual Model Desi EE 80 4 4 5 Antagonist Posterior Anterior Triple Trays ocooccoccccccncccconnnccnnanncn rr nc rra 84 AO VIE Mode Desi cido 86 AA APOCO E 88 Bee LEE 89 ope a TODA poe ee ere ee ne nnn EE 89 5 ll b Fala FOO nr TEE 90 SLZ SIE EIER TOODA bettel EE el 91 e er Overview TOO Diari ai 91 Ditech PROCESS TODD baii OIDO 92 Sit TOOLE ONIS AA AAA A E a ARA 92 zo MOTE Ee te EE 93 Modelno STEDS lea 94 cya o o EE 95 Ira DESIGN EE 95 5 2 24 E SINGIS CODING EE 95 Du Za 2 Zo BROS ie LN EE 106 E FULANI COMICA CROW EE 108 SAZA Ul An ee ien e ele EE 108 EE Eeler CODING S and Fira VOW OM EE 109 AA Al E DiI e GE 109 52120 OM la NN CCCI EE 111 5 2 2 6 Over pressed Crowns and Ce e EE 111 5229 Single Wax UD A AAA AAA AN a ii 111 A LO Wax UI anapemnbinsaioeasvenebansoendasmehansvanseaesnsospensewedegs ogy Gude desedededods A 112 AA e WSIS SCO DC E E EE 113 522212 CUSTOMIZE KT EE 117 DiZzaz kS Iimplant Bars ege Re et 121 AR AA A A O A O O O E E E TISINA 122 Dala o EE 123 Dil 2 LO Data As 123 E FINGIIZe SUC EE 124 E Save STOD WEE EE EEN 125 CEET EE EE 125 Be RETIN OV e vIn rel EE 125 514 MOGEN Reie E 126 ek 2D Cross SSC LOIN WINGO iinet ek ate EE 127 3142 Distance Measuremenes sonararaaarai aida dianas 129 Sia Valdano ria EN 131 A oo o E a 132 39Aape Dongle SerViCE EE 136 TE ag ee EE 137 Do WEIEREN 138 6302 e E ein NEE EEN 141 A e o AA E E E Y PEPEE ETE AEE 1
44. 9 2009 Ej 16 09 2009 le Customer name of the customer for whom the order is created if it s a manufacturing center though this will be the lab sending the order The customer s name the site can be previously registered and further modified in Dental System Control Panel DSCP gt Site Settings gt Sites You also have the option of adding a customer directly from the Order form click the Add customer button to open up the corresponding page in Dental System Control Panel Click on Add and fill in the necessary fields as described in chapter sites You can create a list of sites and modify it at any time add delete move up down etc Contact Person you can indicate the name of a person from customer s side who can be reached and referred to if needed Order Create Shipping Delivery dates to select the date of creation shipping or S delivery of an order click on the corresponding combo box and pick a date from a y PE drop down calendar These dates are automatically updated depending on when the Sun Mon Tue Wed Thu Sat milling center receives the order and what the order consists of 3 3 1 2 3 6 7 8 9 10 13 14 15 163 17 0 271 2 27 M 21 9 3 1 2 3 4 5 6 7 8 9 10 Today 9 28 2009 9 16 2009 BEE T D e p J ha Pa Delivery Type this is a possibility to indicate how the finished design should be sent back to the customer e g Shipped by UPS etc Ship to different address if you want the or
45. 90707 1123 Tech oi 7 7 2009 m Lab Coping 22 23 Zirkon Scanned TTT eS 11 24 05 AM ep I i d1000 20090707 1124 Tech 01 7 7 2009 7 7 2009 Mnf Coping22 Zirkon Modelled eng Reset d selected shit F Label F9 Client Order ID Type Material 11 24 45 AM Labels for the selected orders can be printed by selecting Print gt Label from the right click menu or by hitting the F9 function key The labels are printed with the printer that is selected in Options gt Label Printer Settings The default layout is designed for 40x40 mm labels as shown on next page smile Dental 200910011447 Coping Zirkon Batch ID 2 5 4 Other Check Out Ctrl L Checkin Ctri H K Delete Created Reset Orders in some cases it is necessary to reset the status of an order Scanned Face scanned For example your order is Modelled but you need to have it Scanned in order to make some changes Modelled Closed To reset an order right click on it and select Reset Then choose the status you need Unlock Gent Checked Out Check Out Orders Orders are allowed to be modelled on a computer which is not part of the Dental System e g on a laptop which is brought home this requires an additional dongle orders need to be properly exported from the Dental System database and later re imported Select desired orders and choose Check Out from the rig
46. Apply to all to apply the chosen library to all inlays By selecting None One or Two you can choose how many neighbor contact points are to be used To place the points left click on the surface of the neighbouring tooth where the contact with the inlay will occur Click Clear to delete the points Click Apply to perform automatic anatomy morphing by DentalDesigner The program brings you to the Create Modify mode described further When Create Modify is selected you can modify your inlay by manually placing the blue control points as desired Click Clear to start over Mark Adjust to Antagonist check box to activate Snap distance and Locality radius options The special points for adjusting to the antagonist are not used directly any point within the Locality radius can be moved to the antagonist The Snap distance defines how far point can be moved from antagonist if it is closer than the snap distance the point is adjusted to the antagonist Transition specifies the distance from the preparation line where the minimum thickness is not fully applied If a point on the inlay is further than the transition distance from the preparation line it needs to satisfy the minimum thickness If it is closer the minimum thickness is smaller decreasing to 0 at the preparation line allowing for sharp edges Click OK to go to the Sculpt stage for the further inlay editing if needed Load Pontic Scan This stage is identical to Load Pontic Mod
47. E gt 0 KR Once initial scanning is done mark the area on the scanned antagonist arch for a detailed scan with the available tools and click Continue button da e de dsi You are able to do trimming of the scanned antagonist model if required at the next step Mark the area to delete from antagonist model with the available tools and click Apply button a iHe Trim antagonist model DATES Md ir dd The antagonist model appears trimmed as Aa a T ont 2255 Fock ET khoi T sere 1 Faek Ra L MOFA IL ZS ELA Zus A 143 ER GE DW DI L dt b LATE IEE l J LE d en AA PA A a a M e Can A gedet gn ne i A8 Trim antagonist model D E E D ewe El mY s eb e eb SS Gi PUE pe sshape gt You should now mount both arches on the specially designed fixture keeping the preparation arch below the antagonist and the front side of the teeth away from the metal bar of the fixture as shown on the image to the left It is important to ensure that the objects are not movable on the fixture Then insert it into the scanner with the front side facing the inside of the scanner and click Next to scan fie Heb Insert upper and lower arches Front side faces the inside of the Scanner s gt elo a 3shape gt 507008 oi Cm i CA d At the next step you are required to align upper and lower arches to preparation arch using either one
48. Full Anatomical Bridge Annotations This stage is identical to Annotations described in Single Coping chapter Insertion Direction This stage is identical to Insertion Direction described in Single Coping chapter Margin Line This stage is identical to Margin Line described in Single Coping chapter Die Interface This stage is identical to Die Interface described in Single Coping chapter Crown This stage is identical to Crown described in Full Anatomical Crown chapter Load Pontic Model This stage is identical to Load pontic model described in Bridge Framework chapter Copings This stage is identical to Coping described in Single Coping chapter Edit Connector This stage is identical to Edit connector described in Bridge Framework chapter Sculpt This stage is identical to Scu pt described in Single Coping chapter Split Files Split file stage allows for simultaneously combined design of a substructure and an overlying anatomical wax pattern for over pressed crowns and bridge structures Two separate files are automatically prepared for the output one for the anatomically correct coping and the second one for the pressed pattern These files can then be automatically transferred to the respective manufacturing equipment Settings Liner space when checked allows you to specify the amount of liner space between the anatomy and the framework bridge Remove undercuts F Dril compensation After you click Apply the Lift crown
49. Open Library in the ScanltLibrary application to open the Library Explorer window as shown on the image to the left You can select library items in the listing and preview scanned models When you select the tooth that has not been scanned and its scan is not found the Import Scan alert appears O Scan file not found Import it MA fanned EE talrctad Adie oni Ces Selected library item preview Note You receive a warning message that the library cannot be changed when selecting the standard library items 8 Dental System Installer Installation and upgrade of 3Shape Dental System is done using the Dental System Installer application During the upgrade you will be asked to make a choice regarding the type of installation and whether or not to create a backup etc Note it is strongly recommended to have your system connected to the internet during installation If you cannot be online you are still able to complete the installation but it may be with limited materials settings etc However the settings can be updated later via the Dental System Control Panel When you start the installation process and launch the 3Shape Dental System Installer the first step that you are brought to is to Choose Installation if 35hape Dental System Installer Choose installation ol wiel Geckase contains A 3Shape DentalManager fe 3Shape O DentalDesigner version 2 5 4 8 eN 3Shape DentalDesigner 2008 ve
50. The same principle works for the Redo operation e button Proceed to the next tool for more editing or click OK to complete the process The next tool is called Morphing d It helps you shape your restoration item by dragging specific parts of it Place the special round net on the model and move that part of the model as desired see image to the right The net can change its color and position depending on the view direction top side etc In the Morphing settings window that appears when you select the Morphing tool you can set up the radius of morphing application by dragging the bar The radius can also be changed by holding the Shift button and moving the mouse wheel Morphing settings Ora 1 68 mm Use the colored control points for morphing by clicking and dragging them as desired Hold Shift to move all areas of the same color Hold Ctrl to move an area orthogonally Hold Alt to add remove control points Wax knife settings O 2 16 mm 40 0 um DI H Galzlalslsie Operations and parameters A 7 0 91 8 mm gin 0 05 D e A gt Use the Wax ee i besen to add remove material to the model and to smooth its surface Choose one of the three options and click or paint on the model to apply the operation Select the radius and level of the influence of the wax knife by using the two slide bars or use Shift mouse wheel and Ctrl mouse wheel respectively a Press the button
51. WIELAND Egin Virtual Model Design D ed Auger S ggwg E LJ E See a D E Tmin a a T Dental System by 3shape User Manual Version 2009 Copyright 2000 2008 3Shape AS All rights reserved 3Shape Dental System 2009 User Manual Introduction The 3Shape Dental System is a unique combination of 3Shape s expertise in 3D scanning and 3D CAD software for creating accurate customized dental restorations with high esthetics This new version introduces several significant additions and improvements For example a broadened range of dental indications offering a palette which is second to none unique process optimization through adaptive impression scanning enhanced design efficiency and flexibility and intuitive free form modeling tools All enabling superior restorative work of the highest quality fit and esthetics This manual describes 3Shape Dental System consisting of the following applications Order creation amp management DentalManager Scanning models ScanItRestoration Scanning impressions ScanItImpression Modeling DentalDesigner System configuration Dental System Control Panel Custom libraries ScanItLibrary Installation Dental System Installer NO Un P WN kb 3Shape Dental System supports multiple languages throughout the applications English German French Italian Spanish Japanese Korean and Russian The Softwa
52. YalidatewallThickness True Updated material ID Configuration 11 _walidationi Mame validation Description Connector rea O000 Connectorstrength 0 0000 WallThickness 0 4300 DistFromMarginLine 1 0000 WriteProtected False ForceMinThicknessLevel frathCheck llow violation MateriallD Configuration_11_Material1 ValidateConnector4rea True d alid ateconnectorstren gth i False walidatevWalThiceness True Select Update to update to new item values RECOMMENDED Do the same for all similar cases Keep existing Update At this step it is also possible to download the material settings from Manufactures The Download materials window will pop up offering you to select the sites you want to download materials from Select the desired check box and click OK Click Finish to complete Dental System Upgrade Appendix A System Requirements CPU Intel Core 2 Duo 2 0GHz or better HDD 80GB or more RAM 2GB or more Graphics OpenGL 2 0 support and at least 512 MB of memory OS Windows XP SP2 SP3 or Windows Vista SP1 Network Network Internet connection Mouse Wheel button support Appendix B Using Mouse and Keyboard The use of a mouse and keyboard for common functions in 3Shape Dental System is identical to the standard windows applications Most of the steps in the modelling process involve operations with the mouse The main function of the right mouse button is related to visualization E g with defa
53. acing a gap between the pin and the model Subtractive Pin Model EEN Cylinder offset an offset applied to the margin line for creating the additional cavity space Surface thickness an inward offset of a model used fro 3D printing Trimming Parameters optimization Pin Height 503 Bottom hole size the size of holes at the bottom of the platform used ia 108 to let the liquid for 3D printing to drain out Margin Line Angle 10 Pushing height facilitates pushing the dies out of the model Slope Height 303 Pin spacing 0 040 Cylinder offset 0 10 Manufacturing Parameters Surface thickness 0 00 Bottom hole size 0 00 E Pushing height 1 00 4 4 Scanning Steps In this section you will find a detailed description of how to scan an impression with and without the antagonist 4 4 1 Antagonist None as Before scanning an impression define your order in the Order form Select Impression as an object type and None for the antagonist no Object type antagonist will be scanned Click OK to save your order which will Antagonist appear in the DentalManager order list with the status Created You can also start ScanItImpression directly from the Order form by clicking the Scan button Otherwise select the created order from the DentalManager order list and start ScanItImpression by clicking Next or Scan When the program opens insert the impression model into the scanner and Insert Impression with click Next butto
54. alManager When entering the DentalManager category a screen similar to the image below appears Depending on the dongle configuration Manufacturing Inbox an Add on to DentalManager can be available or unavailable The image below illustrates this category with Manufacturing Inbox present A Dierrial System Control Panel Bentallanager bel Save KO pak Heger Weg Et i De a A Bc a Za Les Dstabare settings d The four subcategories General ERP and processing time Manufacturing Inbox and Working Days are described in details further 6 5 1 General General subcategory contains settings related to the database Database settings a USER PC thresshapedental This Pc H Browse DentaManager DentaMenager e fe e de de de fe ai fe dede de fe Database settings Default settings Test conmection 500 d Opbon lo Item type Imported material ID Replacement material TD Material 20135 0033 Configuration 11 Material Flaberial 20135_Lutz Configuration_11_Maberial2 Material 49146 Lutz Configuration _11_Maberiall Dete ERP S c 3ShapelERP Browse Database settings The database server can be set manually with the help of the Browse button or clicking the Set database server in the upper left corner or a window Click This PC button if the database is installed on the local computer Click Default settings button to add the default instance name threeshapedental as well as Database name User l
55. an arbitrary model Click Apply to all to apply the None chosen library to all crowns Contact points by selecting None or Two in the window you can choose how many contact points are to be used To place the points left click on the surface of the neighbouring tooth where the contact with the crown will occur Click Clear to delete Anatomy library d i d Apply to all the points Occlusal attrition E To adjust the level of the crown s occlusion use the Occlusal attrition slide bar Drag it with the mouse to set the necessary level of occlusion and wait a couple of Cut spline Y seconds to get the result lt lt Advanced settings WC Neighbor teeth The Cut spline function serves for creating a smooth surface from margin line F towards the spline The spline is placed automatically when the Cut spline window is oa 3 open You can Edit existing spline or clear it and place a new one if required Edit spline deen Clear spline Line shaped AN Advanced settings Margin line offset 0 15 mm Offsetande 1 55023 Extension offset 0 06 mm Distance to uns antagonist Regel Distance to Ge 0 05 neighbors c mm Proximal attrition H Sculpt This stage is identical to Scu pt described in Single Coping chapter Coping This stage is identical to Coping described in Single Coping chapter Split Files This stage is identical to Split Files described in Full Anatomical Bridge chapter 5 2 2 4
56. anned or modeled status to select Send to Manufacturer from the appeared menu Only orders with scanned and modeled statuses can be sent to Inbox as shown on the image below mamm dc SM Wasson rem az SV LAO Serie Dera cae Suen Scene A Mossos mn 17 wc D SON SIE 9 15 2009 Johron Ming Abutmert Bkn Soames DEER de Mots Cie ajugo 4 15 3004 tardo Devil opg J Fria toned ep Ge L ndel Erde h ef dere Tolo a Select preparation in the teeth f T overview The folowing orders are ready to be sent bo the specified manul actuertrs Chek send Lo start the upload or dkk the cancel button bo abort 2 Click the Frame hume Haarni Deaton date ees aber Deeg Matens button and select EOS Es a ost and core A eens wradtord ii Dr Deen wes Ber H Piscis Exbd013_J0000008_1946_Tech_01 gt 30177 S Crean dair OSC nr Wa Jiri Gemeng daie 410 2009 Mecha TE dee date Sa e 222 mm 199 mm e SfC Bradford Miir Groo JO Bradford Mir Seng gt Copia 20 Bradford M Saas A EI commands re this feet file FP seg elt Sage Cer iM ETET Te ace ke zeg Cm Click Send and then the Close buttons once the transmission is completed The icon of the sent order changes as shown on the image below EH 9 15 2009 Johneon Milling abutment 9 leo Scanned Johnson bleu i nen oosa Ae tector 3 15 2009 e Diris coor I dan Scheed Johnson Ming T ge E 20091001_1507 vey ry Cle a m Er adier li All orders sent to Inbox are s
57. annot proceed to the next step unless the previous one is completed 5 2 1 Order Step File View Help il The Order step is always available for you when you work on your model in 3 o a DentalDesigner Order You can click on the Order button and select Order form to check out the Order that was created in DentalManager Note This step is skipped when DentalDesigner opens order already defined in DentalManager d Ek al Click Next to proceed to Directions step sane 5 2 2 Design 5 2 2 1 Single Coping ANNOTATIONS The Annotations stage serves two purposes 1 Specifying what part of the scan preparation corresponds to what restoration job This specification is done with the help of blue control points located on each of the restoration items and white labels with job names and index numbers see image below Check the Ignore scanning annotations check box to remove the labels and points that automatically appear on the scan after it is loaded only needed if these have been misplaced during the scanning process 2 Approximately identifying the margin line DentalDesigner is equipped with a versatile semi automatic margin recognition function This means that you need to point the edge where the margin line approximately lies and DentalDesigner algorithm will take care of finding the exact position of the margin line so you could modify it later The action of indicating where the margin line lies i
58. apping the next time the lab sends a similar order and this part of Dental System Control Panel lists these previously stored mappings showing Imported material ID and Replaced material ID The manufacturer can delete selected mappings by pressing Delete if necessary ERP When ERP export check box is marked it allows to export ERP files to a specified folder You can change the Folder path to ERP files either manually or by using the Browse button A powerful extension to the 3Shape Dental System is the ability to share one common database among several computers which improves capacity and efficiency A typical example is when one scanning PC and one design PC are working simultaneously To setup a common database both computers need to be configured to point to the same database setup Note A shared database normally requires a common 3Shape Dongle Service and a shared Server installation 6 5 2 ERP and Processing Time The aim of the ERP export from DentalManager interface is to automatically enable the order information exchange between DentalManager and the manufacturer ERP system such as Microsoft business solution SAP Oracle or JENMAR The exported information can be used for accounting shipping etc The actual configuration is made in Dental System Control Panel go to ERP and processing time click Add and select ID for your new entry fill in the fields with the necessary settings ERP and processing time Edit ERP and
59. arted the Configure services button takes you directly to the Windows Services where 3Shape Dongle Service can be restarted as shown below TI OEE Tile Acton Wee Help e w EI ayl Hm E TO A mies Local ca thew i Thangr Sei wier Him lnrphion Zhiti Sbarugp Type l ila MP YF merren lt Appli apen Eo rararg Procespes a Started Aura mba estar W tenes a Spplet wien Hort Helper 5 Prowedei s Started Automatic Apple sien edd eren ir Pace aed l Pai rial pola alpen L aver Galea Prinsalr imi M nual BP bcapon Minagement Proceppesin Started haan Data Output Directories In 3Shape Dental System the order data and the production data are placed in two separate locations The order data folder for a specific order will only contain files used internally by 3Shape Dental System applications whereas the production data folder manufacturing output will contain the modelled files used for further processing by CAM The content of the production folder can be reproduced based alles Tiara EE LEET on the content of the order folder Spa he Crectory ee Dete e mai burro ouinut te rale remecl o dGebec lores The applications must Know where to save orders and output models To specify the directories to which orders and output models are saved click the Browse buttons to open up a file tree and choose directories The order directory must be a shared network folder if a shared installation is made You
60. aterials from the list that appeared on a screen and click Import 6 4 1 Sites The term Site is used as a common expression for labs manufacturers and clinics Site settings see the image below are fundamental for defining relations between the current and other sites and for the work of DentalManager in order to easily transfer orders from the current site to the central manufacturing site and vice versa Johnson Milling F wl 1 A Copy ID Mot specified MM 192 168 170 37 212 anonymous 0 od i Inbox 1 No TLS Support Test connection In the 3Shape Dental System a globally unique ID is defined for each site This means that each site lab having one or more licenses for Dental System is defined by an ID which identifies this site on the global level This has a number of advantages when transferring orders between sites using DentalManager The External ID is used for interfacing with the third party software The Sub site ID can be used by sites having multiple stand alone installations of Dental System These installations all belong to the same sites i e they have the same globally unique ID and the Sub site ID can be used to distinguish the different installations The Order number site ID is used in the order ID naming template It is recommended to use the globally unique ID for the site which can be copied using the Copy ID button It can be defined for each site whether it Has scanner 3Shape 3D S
61. ation You can add here all the information related to the customer for whom this order is being created The customer s name can be previously registered in Dental System Control Panel although now you also have an option to add a customer directly from the Order form click on the Add customer e button to open up the corresponding page in Dental System Control Panel Customers sites can also be imported to Dental System Control Panel from an Excel file see chapter Sites for more details Please proceed to Customer Information chapter for the detailed description of this section Patient Information In this section of the Order Form you can type in the patient s first and last names The Reference field can be filled in with the customer s social security number or driver s license number or some other information that identifies the customer apart from his name Comments You can add any order related comments here Order Settings This section contains some important information on the order e g Order number The order number is automatically attached to each order and can be defined in Dental System Control Panel Please proceed to chapter Order Settings for the detailed description of this section Scan Settings This section allows you to choose the settings for your order scanning process e g you can choose to scan an antagonist for a more precise result Please proceed to chapter Scan Settings for the detailed description of this
62. ation instead of the mouse The Dental System supports graphics tablets complying with the WinTab standard While in DentalDesigner mode the graphics tablet stylus supports the following functions Second Stylus Tip Support When working with the Sculpt toolkit you can add material to your model with the main end of the stylus while the excessive material can be removed with the opposite end of the stylus Pressure Sensitivity Support When working with the Sculpt toolkit you can increase decrease the amount of added removed or smoothed material by applying more or less pressure on the stylus SpaceBall Support 2 2D Cross Section WiNdOW cccceceeeeeeeeeeeeesseaeeneeeees 128 3 3Shape Dongle Service ee 137 A AUN EN Si 146 Adding Model to Be ee caian irc 162 Anatomical COpingS ccccsscecsceeeeeeeeeeeeeneaaaes 13 38 111 Anatomy EIERE NEE EEN ERKENNEN ENER sacara 142 ne ele Lasa sip 114 ue te Lee E EEN 70 77 86 Antagonist E 48 Antagonist MO lisos oca 50 APPEAR ao 173 A e o O OO re 173 APENAS O id 174 PSSM Y ane anennet nen eae teens 122 B Basic Elements 139 Bridge Elements NENNEN 149 Bridge Framework rra 12 36 107 BROS era 15 16 18 39 48 112 122 C Client Information 19 Closing fl 25 CODING WEE 107 123 E o a EIEI O O O E aeeaanenaeean 19 123 EE 91 COUTO oca 155 Creating ele 9 Custom leie let 160 Customized ADUtMENES cceeeeeeeeeeeeeeeeeeeees 17 47 118 D DATO E 6 Tran
63. beginning of this chapter 2 2 Creating Orders To create a new order in DentalManager you can do one of the following actions Le New Ctrl h ei Refresh ES e Click on the New Gel button in the Main tollbar See Right click in the DentalManager window and select New from the menu see image to the left UNS O e Use the combination of keys Ctrl N Print j After you select New to create a new order the Order Form window appears on the screen 1 Teeth numbering information el Cda mba Log Erem EC Diit Eug Model we Importance Nom m Amtogoren Antagonist bit k 2 Teeth overview eet Depan Module DarkaDengya 209 Face Sean Shape Fate Sanne map Customer Hna e ie Meghiborhosd a d Cent person DIEN Double Gees ge as Pra peeparation scan BS 3 Restoration reste date 03 09 2000 buttons pora date 16 05 2009 a ge i Im 4 Teeth preview uu P bim rte Peterson Wen Ware ted Cen Leper Test Nara rn firkon Zr Coping Charente po Note The amount of displayed fields depends on the settings in the Dental System Control Panel DSCP gt System Settings gt Order Settings 2 2 1 Defining Order Details The following information describes the sections of the Order Form Lab information This field is reserved for the operator s name You can choose an operator from a list which is created in Dental System Control Panel see chapter Operators for more details Customer inform
64. bra o reia ai T unt datn ad tit E ona ice oiled fo or your ir The backup may tae several minutes 1f upgrading using cdrom please don t remove the cdrom during the bathin Bark descripbor AA 13 11 Aaka Mo ch Shae backup Dental tenBackip 0000732 UL ge Cuide backun ont El Backs includes ef badun Me wil inch Current eins Doref mr Mes Current database Please read the instructions in the window to create your backup successfully You can view the content of your backup under the Backup includes tab If you select the Quick backup only check box your backup will include only the current settings material files and the database After you click Continue the Save as window appears so you can save your backup in a folder When this process is completed the program automatically brings you to the third step Advanced Options see next page Shape Dental Sytem Ice Awan ed Option a d Pai LOOS gt You have to specify the dongle and database settings for your upgrade You can choose to use either the local dongle or a PC on the network where the 3Shape Dongle Service is running Likewise you can choose either the default database on the local PC or a remote MSSQL server For the remote MSSQL server you must specify the location of the server and enter the user name and password Click Continue to go to the forth step Installation Li e D m p D i bk D 1 seal pe Dental ler Lar Lera En ei Brie tal
65. canner Has CAD DentalDesigner licenses and or Has CAM a manufacturing machine e g milling machine 3D printer or sintering system Note Only those sites that have Has CAM checked can be chosen in the Order Form as manufacturers The FTP settings should be specified for the central manufacturing sites and they will allow DentalManager to easily transfer orders from the current site to the central manufacturing site Note If the current site also acts as a central manufacturing site receiving orders from other sites through DentalManager then the Manufacturing Inbox Module must be available and the FTP settings for the current site must be specified in the Inbox settings The FTP must be provided by the central manufacturing site and verified with the Test connection button If the connection succeeds a green check mark appears next to the button The contact information of the site can be typed in the provided fields see the image above An important functionality called Import site s from server is available under Tasks in the upper left part of the Site Settings window Pressing this link will automatically Import site s From server import a number of sites including IDs and FTP settings thus facilitating the setup for m From Excel order transferring through DentalManager Johnson Milling This site Bradford Milling ABC Lab Bolton Lab Dent Lab Smile Dental Note Importing sites will only work if your Software Provi
66. click menu AB am et T AR DATS epes 9 1 2009 ba an Lab A s n e LAA Tech EI Ae beten II erno 9 26 2000 sde Der D Last tee days ganes 1500_Tech_01 A arteaga 1 16 2009 Sendo Derial On starting ScanItRestoration the order in the list changes its icon to locked for scanning P 1000 _20090706_1359_Tech_ 7 6 200 7 6 2009 5 Crown 11 Zirkon ScanItRestoration window opens up asking you to insert your preparation 1 Main toolbar rie te A E 3 2 Overview toolbar insert preparation arch 3 Tool forms Freee pide erpi iha kaeida of iha 1 anner 4 Visualization toolbar Nest A 5 Model visibility 6 Difference map 7 2D cross section 8 Material shaders 9 Show undercuts 10 Manipulation toolbar ele 3shape After scanning has been completed successfully the orders change their status from Created to Scanned as illustrated below in the DentalManager order list DR Geen reg Lg rg O gung ent mm were ua rer eat Wi P Wen zap 53 i s Bk O Ven E mu meneame echt Hh wisn Mu Joker Lan e Weir Race its E a i F EN zeien DW Aan Am Let 11 em reese ACEN EE wem HEIN arein GE mie scene LA eg tore crys ana ime rect SAE EEN oam Oy MD ec Doria ee oca D arco ERE bat i A om Teen 1005 Teal RAE EERE weem ERTH here Cine Cros 1 elec Home Seef L Let ren remm A Gei Ch rem een zee surest REE souzen DE beer Cin Frome kan 3 Waster Heddle see In this section you will fin
67. cluded or supported in your particular set up Hence some of the features described and images shown within the manual may not apply to your solution and may require additional license fees if applicable As an example of this restorative design based upon impression scanning requires the presence of the 3Shape D700 scanner and the add on ScanItImpression software module Also the design of customized abutments bars and implant bridges require the AbutmentDesigner add on software module Y BI SCANNING ORDER CREATION Order creation in DentalManager Impression of gypsum stone model scanning with D700 scanner e CAD MODELING Restoration design in DentalDesigner the most versatile and advanced dental CAD application A ORDER SENDING a Seamless order sending with DentalManager sig ORDER RECEIVING ill Automatic order receiving in manufacturing center with DentalManager Inbox F MANUFACTURING PREPARATION A Manufacturing preparation with CAMbridge The table shows a wide range of indications supported by 3Shape Dental System 2009 Click on one of the links of the required indication to go directly to the chapters describing its order creation scanning or design processes Single coping Order creation Scanning Design Bridge framework Order creation Scanning Design Full anatomical crown Order creation Scanning Design Full anatomical bridge o Order creation Scanning Design Anatom
68. complete and saved You can either trim the preparation scan or go straight to the Design step Scanning and Saving finished Chick om arden Io eee im bran Opec aE ze d 3 ae ees pri ries ear 3 2 11 Telescope A telescope scanning is identical to the bridge framework scan please see section Bridge Framework for details 3 2 12 Customized Abutments Before scanning abutments define your order in the Order form and click Scan Once your order has been defined ScanItRestoration will start and ask you to insert the arch with scan abutments Preferably no gingival mask should be mounted now in order to enhance visibility of the scan abutments Once Next is selected a rough selection scan will begin On completion of the quick scan the area around abutments should be selected one by one for detailed scanning When one abutment has been selected click Continue The selected area will turn green and you will be asked to select the next abutment see image below If the abutments are located close to each other you can make one big selection instead of separate ones Detailed scanning will start when selection of all abutments is finished In the following step the detailed scan is used to align the CAD model of each abutment to the corresponding scan When detailed scanning and post processing of abutments are finished you will be asked to align the abutments one by one To align an abutment select two c
69. ctin tach EE DAA PANERA NENA Sue EEN 22 Diao ModE HNT an Ee E 23 2 4 EE Eed leiere lee a Sct eae a o eo 23 24551 Manual Aanding Of Manufacturing lU 23 2 4 5 2 Remote Manufacturing Of Ordere seinneann ARA ARARE ARARE AERA RARA NENNEN NENNEN 23 e bere lee e 25 275 Additonal el gel EE 25 25 1 Finding OA EE 25 29A Generate EE 26 225 3 Print CONtENtES and Eed 26 E EE eenegen 27 236 INDOX Add Om el 27 2 051 Sending Orders rom ANG abona ld 29 2 6 2 Receiving and Handling Orders at the Manufacturing Center 30 2 6 3 Track and Trace Information between Lab and Manufacturing Center 31 A pla e a E Re ES A A a no aa oon Tes w Ses pdasndoas yhasudadeansasesydoi baie doves pigs vadsvunt etnies 32 Bre ISO ECS e EE 32 AS A nn lla E ll 34 i ye Ss EE 34 E BAS A A O T 36 329 FUAN tOM Ca ege EE 38 3 24 FUI Anatomical ee TEE 38 3 2 5 Anatomical Copinas and FrameworKossusueratr id 38 A tee E 20 Ge OMV NVE NOE S ee e Eeer EE 39 3 20 QVer pressed Crowns and ge e 39 EAS SO 39 GC SEET e 42 oe all Telescope sti eee eee a eebe 46 3 2212 CUSTOMIZOO ADULIMEGNUS siii ere eieaeasdaceced iii 46 32 13 Implant Barscand Bridges iii eee eae te tase eek tenet ane 48 Se E ANLAGOMSE TEE 48 SoZ AMA JONS E MOE ME 50 2 Os DOUDE Eege lada 57 SAE elei DEE 60 Dios SCALP O A etn EE Ee 66 Aol A O 67 42 Preparing TOr SCanning soii 68 A 719 CAM E Le e EE 69 A SCAMMIMNOG SLC DSi EE 70 Adal ANEAGOUISE Ve E 70 GEN WN e SN 442 Vital Model DESIGN REENEN
70. ctor type Facial distance the approximate distance from the connector control splines to the facial side Palatal lingual dist the approximate distance from the connector control splines to the palatial lingual side Occlusal distance the approximate distance from the connector control splines to the occlusal side Counter occlusal dist the approximate distance from the connector control splines to the counter occlusal side e Settings specific for the Circular and Elliptical connector types Scale factor scales the default connector control splines Shift back moves the connector control splines in the lingual direction Distance to spline places the center of the connector control splines a certain distance vertically from the Placement overview spline The default value of 0 ignores the placement named Auto in DentalDesigner Height to width ratio defines how high the initial shape of the connector control splines should be according to the width 6 4 Site Settings A Site Settings category contains the setting for defining Sites Materials Countries Manufacturing processes and Operators All these subcategories are described in details in the following sections The image below illustrates the main window of the Site Settings category Click on the desired subcategory to get the corresponding settings W PN A kel bas sl Fal Ske rl Ai Wer Dal Ste r L optroi Panel ol ae Ld Save CH Back
71. d a detailed description of how to scan different cases step by step 3 2 1 Single Coping One of the simplest scanning operations that can be performed is scanning a single die Before scanning a die define your order in the Order form and click Scan When the program opens insert the requested tooth into the scanner Hint Place the die at the center of the plate The scanning process starts on clicking the Next button Insert tooth 24 Put a the corro of miort aen plata te E ds e Ee e It may take a minute for the post processing to finish Your model is now scanned and saved If you would like to start the modeling process in DentalDesigner click the Design button It is not necessary to close down ScanltRestoration after each scanning process Scanning and Saving finished Glick on quinine window bo rodeo single san Operations rs Sie dre fei se A CG bas s T 3shape 3 2 2 Bridge Framework Using DentalManager create a new order and make necessary settings for a framework bridge in the Order Form Having completed defining a new order click Scan button to proceed to the scanning step This opens ScanItRestoration window asking you to insert the arch as a sectioned cast model or an impression The cast impression should be fixed with its flat bottom side to the black scanning interface plate It is very important that the object is secured and cannot move during scanning Both shou
72. der of the Dental System has already supplied these settings to you The discussion and figures in this section assumes that the 3Shape Dental System is a standard non encrypted system For encrypted systems several of the settings cannot be edited by the users as they are already provided by the Software Provider of your system and should not be changed Sunny Clinic The users can also import sites from the Excel document see the image to the left which makes the workflow easier and faster The format of the Excel file needs to be as dih Add follows ga Add Dentist v me 010001 Country SECH John Silver 800 502 0958 at Move down 12 Ocean Road 800 502 0959 14 Maple Street Jsilver exmpl au City www jsilver com State Contact person John Silver Name John Silver ZIP Code In the Table window see the image to the left you can edit your site list at any time add copy delete etc Click on the desired site and its settings will appear in the right part of the window 6 4 2 Materials These settings see the image below identify materials to be used for the construction elements Please see Basic Elements chapter Materials subcategory for the detailed description of these settings Edit Material ID party software Mame Shader material Default scan module Default design module Lise colors Configuration 11 Materiall External ID for interfacing with third rca O Use Seefe 2 Us
73. der to be shipped to some other specific location check this box and fill in the blanks with the information on a new address 2 2 3 Order Settings Order settings Order Number is a unique combination of parameters which is automatically attached to each order and can be defined in Dental Order number AAA AP eo System Control Panel DSCP gt System Settings gt Order Form importance Settings Design Module DentalDesigner 2009 MM You can choose the way your order number is reflected in the Order Form e g first goes SiteID then Date Operator Patient s last name etc Select Unspecified if you don t want a parameter to be seen in the order number External Order Number if you want the external ID to be added to the order number select External Orderld from the drop down menu in Dental System Control Panel DSCP gt System Settings gt Order Form Settings gt Define template for order ID generation and type the number in the Order Form It will be automatically added to the order number Importance choose between Low Normal or High options to indicate the level of importance for the order Design Module you can choose here between DentalDesigner 2008 and DentalDesigner 2009 depending on your preferences This option is very convenient since you can choose to use the familiar to you version even after upgrading 2 2 4 Scan Settings Scan settings S e a Object Type choose the type of object to be scanned Impres
74. ds of implant systems can be added and used to create customized abutments To be able to create customized abutments a number of auxiliary CAD models must be prepared and added into the dental system Top cap libraries Implant systems Ka Abutments category contains two tabs with the corresponding settings Top cap libraries and Implant systems Click on Top cap libraries to get a window as shown on the following image ap libraries Artificial Anatomical Cylinder Standard offset Prepared Ds Change ID Prepared The Top cap libraries settings allow definition of abutment top caps used during abutment modelling The functionality is similar to that of defining pontic libraries Top cap libraries can be ope Gel P x E E A Recyele hin implant models Briail Tee ter Lira ry D Wiel S I mm aati bee WES 3 5 me suite hars WS tren ant D ie rita Eran gbatrnsnt models e Sac Wiel mnrieiee Ml Tr inter ace WG Dir interface To handle the CAD models related to customized abutments the 3Shape Dental System deals with a number of concepts related to the grouping of these files Implants Implant 1 Implant 2 Implant 3 Implant 4 Implant System screws Interfaces Bases Screwl Interface 1 Bases 1 Screw 2 Interface 2 Bases 2 Scan ab 1 Interface 3 Bases 3 Interface 4 Abutment Kit The highest level of grouping is an Implant System which t
75. e de Te mae la air Pr ao ee da beatos a The virtual model design is now complete and the model has been saved The final models from the virtual model design are automatically saved in the order folder in the subfolder Virtual Trimming If you would like to start the modeling process in DentalDesigner click the Design button 4 4 7 Post amp Core Scans The D700 scanner s impression scanning capabilities enable the scanning of post amp core something which is impossible on traditional gypsum scanners due to the narrow core The scanning of post amp core is identical to the standard impression scanning 5 Modeling DentalDesigner DentalDesigner is an advanced software package for designing high precision customized restorations from 3D scans of dental impressions Using the latest technologies the DentalDesigner software facilitates fast and easy 89odeling of complex constructions as well as enabling automatic manufacturing of the final restoration model on computer aided production equipment DentalDesigner launches after you have placed an order in DentalManager scanned it and clicked Model The image on the left illustrates the scan file that goes into DentalDesigner for modeling and the image on the right shows the output model ready for manufacturing 5 1 User Interface After you have sent your order for modeling DentalDesigner starts up and the main window similar to the image below ap
76. e button and select a library pontic 6 Click the Anatomy button 7 Select all units in bridge in the teeth overview 8 Click the Bridge button 2 2 1 9 Single Wax up Order details Zirkon Wax up Zr Telescope Abutment Index 13 Additional i 3 E 1 Select preparation in the teeth overview 2 Click the Frame button and select a wax up 2 2 1 10 Wax up Bridge 1 Select preparations in the teeth overview Order details 2 Click the Frame button and select a wax up 3 Click the Bridge button and select a wax up bridge Index 25 Additional 2 2 1 11 Telescope Order detail Kl 1 Select preparation in o the teeth overview 2 Click the Telescope button Primary telescope crown Er Abutment Index 12 Additional 2 2 1 12 Customized Abutments 1 Select preparations in Order details the teeth overview gt 2 Click the Abutment t button Anatomy Kit Wital 3 5 mm Not in group Index 4 Additional The process of defining an order for the customized abutment design is identical to the one used with the other types of restoration but demands attention to some additional details in defining the order settings Next to the Abutment button you see menus with different options which are to be selected manually such as type of system and type of kit within this system used in the abutment
77. e 1 D d uo L ri nor AL L Kand eee e ia E EN H D AC a D 3 Trim preparation scan SHAA NEE Hee kt Example 2 Trim pre preparation scan APO eines CODAE Example 3 Scanning and Saving finished Click an cren winden nade ne ican Eran eg SS i a ho e j a eene 3ashape 3 3 Scan Settings Select File gt Scan Settings from the main application window to modify settings for your particular case if necessary Scan Settings General General Scanners Advanced a R f Die in a bridge height below margin Scanning height line when scanning an arch and then separate dies one by one you annotate the teeth by placing the points on the margin Single die scanning height line This Die in a bridge height below margin line parameter defines the distance down from the margin line that will be scanned Die in a bridge height below margin line Arch scanning height Save Single die scanning height is the height of a single die that will be scanned when arch is not used Keep raw scan data Arch scanning height is the height of the arch from top down that will be scanned Keep raw scan data when checked saves the raw scan files that can be used from reopening and editing saved orders Scan Settings Scan Settings Scanners Ss General
78. e Seefe 2 Minimum manufacturing values validation ITE AFaATAI vals tion settings Validation enforcement policy Minimum wall thickness Distance from margin line Minimum connector area Minimum connector strength Mo enforcement User can choose to ignore violations Always enforce but notify the user first Always enforce without notifying the user 7 00 file 4 00 mm 6 4 3 Countries Countries settings identify the country to be used in the site data see the image below Use the list to the left to choose the country you need When you click on a country the ID and Name in the left part of the window automatically change You can add delete countries at any time Country Denmark Australia Austria Belgium Canada Switzerland China Cyprus Czech Republic Germany Egypt cr sir Edit Country ID Mare 6 4 4 Manufacturing Processes The Manufacturing processes category see the image below specifies how the construction elements are produced The users of the Dental System applications have one of more manufacturing processes available e g milling machines 3D printers or sintering systems please contact your distributor to learn more of the available processes For each Manufacturing process it is possible to define manufacturing specific settings e g drill radius of a milling machine Edit Manufacturing process Milling DO Amm Milling F0 Smm ID Configuration 11 ManufProcess30
79. e offset is the distance from the bottom of the abutment where the offset is applied Load Abutment top cap Anatomical d Standard offset Artificial E Cylinder Prepared File name A C Program Files 3Shape Dental Sys Browse x se Top Cap Abutment top cap Tap cap shape Transformabon Hots sen mode Free Fiori moe irme Lkekrruts a Vat to Emergence Profle Fit Top Cap Gesfomab n Fall bop Lap bordar y informatinn Shaw tap cap angle Chew tap rap under cts Callitinns bherween models Lika Lkek AR CS Lo WE AN aq At the Load stage you can load a template abutment top cap from the library At this stage you only load the model while at the next Top cap stage you are able to model the selected top cap as desired DentalDesigner automatically selects a template top cap corresponding to the index of the tooth being modelled Click Apply to view the selected top cap Click OK to move to the next step At this stage DentalDesigner provides a default position of the previously loaded top cap however you can transform the model as desired using a number of tools Transformation move the model by left clicking on it with the mouse To scale the top cap left click and drag one of the green control points when pressing Shift the top cap will be scaled in all directions Rotation mode specifies how the top cap is rotated If Axis is checked then the ro
80. e than one telescope all telescope will have the same direction however they will have different insertion directions see the following image ST Ce E Toco HR A aoe ria dep Terra J 3shape gt 1 4 Telescopes 5 One telescope direction The Telescope direction stage is automatically activated when you leave Annotations stage The Set direction button appears in the Tool Forms All telescope preparations are initially rotated into a position proposing a common telescope direction You can rotate the model into your preferred position and press the Set direction button to save the current point of view as the telescope direction Click OK to move to the Insertion direction step Primary Telescope Overlay At the Primary telescope overlay stage the program automatically creates an initial telescope that you can modify as desired The primary telescope consists of two separate parts the basis coping and the telescope cone grey The basis coping defines the shape of the telescope rim and guarantees minimum distance between the final telescope surface and the interface The basis coping settings can be adjusted on the Base coping settings group which contains the same options as a regular coping please see Coping section of the Single Coping chapter for more details After the modelling the telescope surface will replace the basis coping overlay surface Before clicking Apply After clicking Apply The upper and lower l
81. ed model types in the Edit Anatomy and Pontic Libraries frame Click the Save button to Edit Anatomy and Pontic libraries ID 45126_Own Library46 Change ID Name Own Library 33 Library path C Program Files 3Shape Dental System Control Library path Panel Library SShapeCustom Crowns Chr Di Library is available for the following types Crowns and Crown Pontics Frame Pontics store your model changes in the library Scanning crown 14 ra E Ei tE 5 Info Server 4 3 1 3 20 Shote Scanning Ser Scanned tooth Switch back to the Scan Library window select the created Library from the list and click the tooth to scan The selected tooth becomes colored in blue If the Mirror Tooth checkbox is marked the mirrored tooth will be saved as well The already scanned teeth appear colored green Insert your model into scanner and start scanning by clicking the Next button On completion of the scanning process you should edit your scan Perform transformation of the scan by dragging the orientation points with the cursor to the desired position 3shape 1 Scanned tooth 5 Aligns the orientation box to axes when marked 2 Currently selected stage 6 Returns model to original position 3 Editing stages 7 Orientation box 4 Information window 8 Drag points with cursor for desired orientation Scale your scan by selecting the Scale Factor as shown on the image below It is vital
82. el described in Bridge Framework chapter Edit Connector This stage is identical to Edit Connector described in Bridge Framework chapter Sculpt This stage is identical to Scu pt described in Single Coping chapter 5 2 2 7 Onlay Veneers Annotations This stage is identical to Annotations described in Single Coping chapter Insertion Direction This stage is identical to Insertion Direction described in Single Coping chapter Margin Line This stage is identical to Margin Line described in Single Coping chapter Die Interface This stage is identical to Die Interface described in Single Coping chapter Veneer This stage is identical to Inlay as described in Inlay Inlay Bridge chapter Sculpt This stage is identical to Scu pt described in Single Coping chapter 5 2 2 8 Over pressed Crowns and Bridges Annotations This stage is identical to Annotations described in Single Coping chapter Insertion Direction This stage is identical to Insertion Direction described in Single Coping chapter Margin Line This stage is identical to Margin Line described in Single Coping chapter Die Interface This stage is identical to Die Interface described in Single Coping chapter Crown This stage is identical to Crown described in Full Anatomical Crown chapter Load Pontic Scan This stage is identical to Load Pontic Model described in Bridge Framework chapter Coping This stage is identical to Coping described in Single Coping cha
83. em Cement gap Extra cement gap 0 080 mm Distance to preparation line mm Smooth distance mm Please see Die Interface section of the Single Coping chapter for information on Cement gap Extra cement gap Distance to preparation line and Smooth distance CGverlay The Overlay tab contains data for specifying the general outer surface of an item Name Wax gt Gold Crown tangent Wall thickness mm Wall thickness is the distance between the outer 8 overlay and inner cement space surface Preparation line offset mm Offset angle gt Preparation line offset Offset angle and Extension E offset are illustrated below Extension offset men Edge design lingual offset EEH A Margin line offset Edge design facial offset mm B Offset angleC See A ee Se Extension offset Edge design interprox1 offset mm Edge design interproxz offset RED D Margin line Crown degrading SS degree Perform cutting to antagonist mm Edge design lingual offset These are the settings for specifying the distance from the margin line from Edge design facial offset which you cut back the anatomical crown Edge design interprox1 offset Edge design interprox2 offset Crown degrading is the default value for degrading of the library crown Zero signifies no degrading of the library crown Select the Perform cutting to antagonist check box if you want the corresponding action to be performed Specify the Cut distance to antagonist below l Overlay The Inlay
84. embly This stage is identical to Assembly described in Customized Abutments chapter Edit Bar This stage is identical to Bar described in Bar chapter Implant Bridges Annotations This stage is identical to Annotations described in Single Coping chapter Insertion Direction This stage is identical to Insertion Direction described in Single Coping chapter Parametric This stage is identical to Parametric described in Customized Abutments chapter Sculpt This stage is identical to Scu pt described in Single Coping chapter Assembly This stage is identical to Assembly described in Customized Abutments chapter Margin Line This stage is identical to Margin Line described in Single Coping chapter Die Interface This stage is identical to Die Interface described in Single Coping chapter Coping This stage is identical to Coping described in Single Coping chapter Load Pontic Model This stage is identical to Load Pontic Model described in Bridge Framework chapter Edit Connector This stage is identical to Edit Connector described in Bridge Framework chapter 5 2 2 14 Post amp Core Annotations This stage is identical to Annotations described in Single Coping chapter Correct placement of annotation point for Post amp Core operation is shown on the image Y y Insertions Direction This stage is identical to Insertion Direction described in Single Coping chapter Margin Line This stage is identical to Margin
85. embly step helps you improve the internal structure of the abutment top Assembly settings cap Use screw hole EE mm Choose the Use screw hole check box to create a screw hole from the top of the i SC abutment top cap set by default Extra drill hole radius 0 mm Define the Vertical screw offset and the Extra drill hole radius in mm To better view the changes in the visual appearance of the model use the 2D cross section Thickness map window Geo iz The Thickness map is a useful option to have a clear idea about the thickness of the ee Gei complete abutment top cap structure Thickness 5 Go to the Sculpt step to make the corrections in the external view of the abutment please see Sculpt section for more information Emergence Profile As was mentioned above the traditional way of designing abutments and not using the Parametric Abutment Generation tool which in this case should be disabled in Dental System Control Panel consists of the following steps Emergence profile Load Top cap Sculpt and Assembly Abutment emergence profile Gingival Spline A Vertical base offset 0 00 mm Gingival spline offset 0 00 2 mm Emergence profile shap amp 4 E Reset current spline Reset all splines To edit the vertical dimensions of the emergence profile unfold the Emergency profile shape group of settings This will automatically provide a digital image of the cross section of the model and rotate its profile to displa
86. en status page The location of 3Shape Dongle Service can be defined in different ways It can be manually typed in it can be defined by clicking This PC button if Dental System Control Panel is started from the PC where 3Shape Dongle Service is installed or you can click on the Browse button to open up a file tree and locate the Dongle Service The Dongle service port specifies the network port used by the service If this port needs to be changed e g due to a Firewall or if another application is already using this port it can be changed here and at the same time it needs to be manually changed in a configuration xml file located with the service When 3Shape Dongle Service is located and the port specified the connection can by tested by pressing the Test connection button If the connection is successful a green check mark is shown otherwise an informative error message appears The Open status page button opens a status page that provides fast and easy overview of the licenses available on the system It shows the number of licenses points available for different applications the number of licenses currently in use and which systems are using the licenses It is also possible to check for dongle updates from within this page and the log file for 3Shape Dongle Service can be displayed The log file is a useful debug tool in case the Dongle Service does not respond as expected If 3Shape Dongle Service for some reason needs to be rest
87. er has been defined in the order form the scan process can then begin Once a bite has been created there is usually the need to cut off excess material for the scanning to run faster The images below show the bite mounted on the cast A blade should be used on the sides of the bite model to clean off the excessive bite material pushed over the sides of the cast Care should be taken not to cut through the area where the teeth have made an impression on the bite Untrimmed bite model Trimmed bite model Before scanning define your order in the Order form and click Scan When the program loads insert the cast with the bite mounted When you click the Next button a rough preview scan begins On completion of this quick preview scan the area of interest should be selected for detailed scanning Remove the bite once detail scanning is complete The cast should remain in the scanner Once the bite has been removed from the cast the same selection can be used for the detail scanning of the cast Now that the bite and the model have been scanned the scans are displayed together on the screen The bite scan might need trimming Use the selection tools to mark the unnecessary areas of the bite scan Basically the edges should be removed leaving only the imprint of the upper teeth Click OK after you have finished The rest of the antagonist bite scanning is similar to the bridge framework scan please see section Bridge Framework for details
88. erial performing the following operations Add add a new material to the Material list as illustrated above Zirkon Titan Wax When adding a new item a unique ID will automatically be provided and you must then provide meaningful information such as Name etc Copy copies the currently selected item highlighted in the list In general all data with the exception of the ID and Name is copied to the new element but there can be exceptions Delete deletes the currently selected item This does not delete the item immediately it is deactivated instead and placed in the Recycle bin where it can be finally deleted or restored back to the Material list Move up down moves the currently selected item one place up or down in the list To change the item s ID click Change ID button and select a new ID an identification unique among all items The Name is a regular text string not necessary unique that acts as the visual identification of an item wherever the item appears in Dental System applications it will be identified by its name Each material item may have an External ID which is used when interfacing with third parties e g a central manufacturing site An optional Shader material may be chosen for improved visualization of the construction elements in DentalDesigner Default scan module lets you use choose the application to be used for scanning ScanItImpression 2009 or ScanItRestoration 2009 Choose Use
89. ess TOO Da usina 94 PFOCESSES sur 156 MIU CURAN 156 Processing TIN ria AR care corre ARA A ERA 159 R Remote Manufacturing ee 23 ge aaa 23 Remove Araure iia 126 Re Sending Orders ENNER EEN EAR EES 32 S SAVE OLED EE 126 SCAM SetlINGS nis avers saws veers ERRA ARANARAK AND 20 66 69 Self belle DEEG 66 SEENEN 160 SCANITRESCOFALION iras 32 Scanner msm dd 3 6 Tra sportatio TEE 6 Scanner CAMDEN ne 5 S COMMING ii 21 32 66 70 n gll e EE 66 leie TEE 32 8198 1 ere no E A A E A 21 A rank A AEE E T 70 SCAN e Ver EE 3 4 SGUIDE riar a a ao 123 Select Material naaa 19 Klee e EE E 29 Ol ge la Sita 29 KE ln Le 151 SINGLE COPIAN Nal 11 35 97 SIMS Tracia iaa 77 SINJIE Wax Girar 15 39 113 o E o OO aaa 152 KIRCH Bleiw en dl e EE 161 SMU EE 109 SLDS arras 70 96 KA Ke Ya En Le EE 96 SEAN eRMa E ea ea eee eee AAA 70 System Requirements ANE ENNEN NA REENEN 173 E ENEE lee 133 T Re le EEN 16 46 Telescope Annotation NEEN 114 TODAS OS LL o 92 el 127 MOGGCINAG PI AO ooo E oeeaee 127 Track and Trace Information 31 Beate tele d Le WEE 6 RR E 6 SCAN tee ta ee mateo a aaienee 6 U UD BHOG cani 124 User een Ee 7 32 67 USIMONMOU SE ra 173 V Vandali EE EE 132 Virtual Model Design ccccceeeeeeeeeeeeeeeeeeeeeeees 73 82 88 Visualization Reie le EE 93 W WV KE 16 UK e KG ele EE 42 114 Kufa ien TEE 1 WOEKING EE 159 RIVE 159 Your Personal Notes WIELAND EXPECT THE DIFFERENCE BY WIELAND As a major supplier of
90. esults without compromising the ease of use Apart from the newly added features the description of the scanning process in the manual also applies to the previous scanner models D640 and D250 1 1 Unpacking and Installation of D700 The D700 scanner is packed together with all the accessories needed to connect it to the scan server PC and operate Special packaging materials made from transport security foam are used to protect the scanner and accessories during transportation When unpacking please verify the package contents and contact your 3shape re seller s customer support if any part is found missing or defective Content of the box D700 Scanner MIDA User Manual Calibration box Content of calibration box The calibration box contains 1 Power supply 2 USB dongle key red or blue 3 Calibration dot plate j 4 Pontic scan pin E y bk Wegen 5 Pontic scan pin protection foam A 6 Scanning clay 7 USB cable 8 3 x Scanning plates _ 9 Calibration Square 10 Power cord The D700 scanner is tested sold and delivered together with an approved PC 3Shape does not guarantee the functioning of the D700 if third party software is installed on the ScanServer PC if third party computer peripherals are installed e g USB flash key WLAN adapters or if the software is installed on a different PC Note The default Windows user name and password for the 3Shape PC is scan
91. eth or use the standard Shift left click to select a row of teeth A multiple selection allows bridges to be applied Right click on the selected teeth in the Overview map to clear your selection D char AC Click OK when the order has been set up as desired The order is stored into the database and handled by DentalManager Click Scan to start scanning immediately Click Cancel to terminate the order definition 2 2 1 1 Single Coping 1 Select preparation in the teeth overview Order details 2 Click the Frame button I pogaca Zirkon Zr Coping tangent J Telescope 4 Abutment Index 14 Additional 2 2 1 2 Bridge Framework 2 Order details Index 4 Additional 2 1 3 Full Anatomical Crown Order details Index 26 Additional cua Silhouette Select preparations in the teeth overview Click the Frame button Select pontic in the teeth overview Click the Frame button and select a library pontic Select all units in the bridge of the teeth overview Click the Bridge button 1 Select preparation in the teeth overview 2 Click the Anatomy button 2 2 1 4 Full Anatomical Bridge Order details Index 25 Additional Index 12 Additional Anakorny SPS e NE Type Silho
92. h rapid prototyping milling machines whose specific output is generated according to vendor s specification Please refer to your local 3Shape dealer distributor OEM partner for assistance on production related issue The Generate CAM output function is used to have the modeling exported in a file format which is suitable for production typically STL or other proprietary 3D file formats The term CAM output is used as different production machines may require different kinds of output and 3Shape Dental System supports a number of them It is possible to generate CAM output from the Modelled orders if it is supported by the current DentalManager system In this case it can be accessed from the advanced tab when you right click on the order if the order is for local manufacturing i e the Manufacturer chosen in the Order Form is the site itself then CAM output is created directly from DentalDesigner 2 5 3 Print Contents and Labels d1000 a LOU A 57 The current view of orders can be printed on a standard Printer Right click on the order and select Print gt List from the menu or hit the F8 function key Stas l The orders are printed out in the form of a table as shown below ae eration Delivery f e Number Client Items Material Status Height date date 71712009 Crown 12 22 20090707_1045 Tech_01 512008 Frame bridge Wax zirkon Created 11 29 09 AM 12 22 Bag han gege 200
93. he Smoothing slide bar defines the amount of post processing applied to the automatically extracted spline The Show angle graphics checkbox enables or disables the advanced angle graphics The Set margin direction button defines the direction which best represents the current die and helps to place the more precise margin line Margin direction is visualized with the help of green arrows as shown in the image above The Set individual insertion direction button provides an alternative direction to the individual dies which may be relevant for certain bridge orders DE Note Please make sure that your manufacturing device supports individual insertion direction usually RP machines or 5 axis milling machines are recommended here Check the Individual insertion direction check box first to activate this function The Deviation from global shows you the deviation from the global insertion direction Click Apply to view the result click OK to move to the next Die interface stage DIE INTERFACE At this stage the scanned model is being cut with the help of the defined margin line The remaining part of the model is offset to create the inside called interface of the item being modelled The modeling window on this stage looks similar to the following image Coping 2 CH Finish d Remove artefacts A Margin line Mame Zircon Coping tanga Difference map ES Advanced settings 3 Cement gap 0 045 mm Extraceme
94. hown in the Sent folder of the Orders tab S a Other filters 2 eee Checked out Seng m All open 2 6 2 Receiving and Handling Orders at the Manufacturing Center The orders sent by the labs to the Inbox can be taken from there by manufacturers for production The setup process is described in Manufacturing Inbox chapter of Dental System Control Panel section of the manual This section describes how to receive and handle orders from the Inbox Run 3Shape DentalManager select Inbox tab and right click the chosen order from available to select the desired action from the appeared menu you can also use the toolbar buttons eS es Le i 3 a ee A ME S cm ae NOE CH Erice Mumia Delivery date Let lems l ae 8 Lei DONNA 2514 Tech D pur napa CTT EN Kinoe P Ordes Auto Accept i dun 20090500 144 wea Ursdhrd ming Lopetg J v Y Accepl A Accept ll Nam Gi Keect Cll k Ce Chris da ge Open d CH 30 Preview Ce ah Rete shi FA Advanced D The system can be set up to accept orders automatically and create CAM files by default If this action is desired the Inbox Auto Accept check box has to be selected in Dental System Control Panel DSCP gt DentalManager gt Manufacturing Inbox gt Inbox Auto Accept The incoming orders can be inspected with Open or 3D Preview options before being accepted The orders can also be accepted manually using the corresponding buttons Accept
95. ht click menu When the orders have been processed they can be re imported into the Dental System database Select the orders ready for check in and select Check In The orders will be integrated and status updated After clicking both Check Out and Check In you will be prompted by a window Browse for Folder to select a folder for storing order copies Deleting orders you can delete an order at any time if it is not locked Right click on the order and select Delete You will be prompted by the confirmation dialog A Select Orders with common values orders that have common values e g they have the same status or client SS fs Can be selected as a group to assist order handling Udala N Sivas y S WE K For example you can select all the orders that have the amp SUNDANESE OK Ban wi geese athena yds same patient GEN o enee e 3 To select orders with common values right click on one of Sue ES a e the orders and go to Select Choose one of the suggested pones ba NS sa parameters Mena sani 3 Advanced Print Reset Import Ctrl Exp Export Orders orders can be exported from the system to a file FTP or mail ort To File Ctrl E Sr serene cap The selected orders are compressed and handed to the desired export control Exp Exp Exp Exp ort To karl Ctrl L ort ERP File Ctrl P To perform the action right click on the order go to the Advanced tab and select
96. ical copings and framework e Order creation Scanning Design Inlay Inlay bridge Order creation Scanning Design Onlay Veneers Order creation Scanning Design Over pressed crowns and bridges Order creation Scanning Design Single wax up Order creation Scanning Design Wax up bridge e Order creation e Scanning e Design Telescope 0 Order creation e Scanning e Design Customized abutments e Order creation e Scanning e Design Implant bars and bridges e Order creation e Scanning e Design Post amp core e Order creation e Scanning e Design 1 Scanner and ScanServer 3Shape ScanServer application works as a driver to pair a 3D scanner with the scanning software While having the advanced features the Scanner and ScanServer application are still easy to operate and require a minimum amount of training The simplicity of the process is achieved with an easy and quick fixation of the scanned object followed by a click on a button in the scanning software to initiate the scanning process The scanning process is described in details in the Scanning Models ScanItRestoration chapter The introduction of the new advanced 3Shape D700 scanner builds up on 3Shape s scanning expertise and is optimized for scanning of impressions and full dental gypsum models up to 40 faster and with greater details than 3Shape s previous D640 scanner The D700 scanner guarantees superior scan r
97. ie define your order in the Order form and click Scan When the program opens insert the requested tooth together with its wax up into the scanner als Hint Place the die with the wax up at the center of the plate Fis Hee Insert tooth 24 with E wax up mounted EI Pult 9 Sp the t pieg Of Ir pgarc plane E mz a A EI f ii o RK KRAN 3shape The scanning process starts after you have clicked Next OO a SEP CNDm se o Carefully remove the wax up from the tooth and click Next to separately scan the die GGmmg da E enn m 6 After the die has been scanned the program automatically aligns the wax up and the die scans and saves the result If you would like to start the modeling process in DentalDesigner click the Design button It is not necessary to close down ScanItRestoration after each scanning process a e il an Scanning and Saving A finished Ki aaa bi t CON D ai D H Tei v m S ip 3shape gt The image below illustrates the cross section of a model with the clipping plane being used E Im 1 gp pm ER Scanning and Saving Lt Mi a AA VA IA PA LA pe ere iHe goe ig DER 3 2 10 Wax up Bridge Using DentalManager create a new order and make necessary settings for a wax up bridge in the Order Form Having c
98. imits of the telescope cone are defined by the shape of the blue upper and lower control points The upper control points define the transition between the angular telescope cone and the curved telescope top The shape can be adjusted both manually by dragging the control points along the telescope cone surface or using the settings The points can be added and removed with the right click on the blue line and selecting Add Remove The right click menu also offers a Fast edit functionality which when activated lets you easily draw or click where desired for the program to place points automatically The lower control points define the transition between the telescope cone and the basis coping surface as well as the shape of the cone The shape can be adjusted manually by dragging the control points If the telescope cone surface intersects with the basis coping surface the lower control points and the connecting lines that need to be moved will be marked with red Note You will not be allowed to complete a telescope with intersecting cone and basis coping surfaces Telescope Crown The shape of the telescope can be adjusted through the Primary crown settings Settings group il TetescopeOverlay Ti v e The Angle of the telescope is measured along the telescope primary direction and can be adjusted dynamically Base coping seta e The Smooth slide bar changes the smoothness of the green telescope top lines that define the shape
99. impresor http far Zoe complice amen Remota Mee E m a ai wie meman Ferh ish Iriesrel Lies Mania wolfe The window indicates inserted Dongle Number Number of Updates Applications Enabled and Remote License Management Server URL When Dental System application is opened the 3Shape Dongle Service allocates one client point for it and when the application is closed the license is freed once again The client point information is also available in the status page the status page shows additional information e g how many points are currently in use Dongle Update The link is used to update dongle inserted in a host computer Only one dongle should be connected to a computer at any time When the dongle is replaced with another one its information can be updated with the Refresh key Dongle update can be done either manually or via the internet by clicking the corresponding buttons The default Remote license management server URL should not be modified unless instructed by 3Shape representative Please refer to the Internet Connection settings if a proxy server is in use at the server s side For the manual update you supply your dongle number to 3Shape representative and receive a dongle update code that you need to fill in the Enter update code Manual Update form then click OK button The dongle is updated if with ST the correct code Information x For the Internet update option you simply need to click the correspond
100. ing button Se to have the dongle updated when update is available No dongle update 7 No dongle updates available message appears if no updates are available WR Key file updated Connection Setup The default license update Server URL can be viewed and tested in the Connection Setup window o Peal Fiaa d aal imal ban e elt H ae er in A Jk rie m Lona ii i e App L F Li i Connection setup In order to be able to Lodate dongles ve the Intemet the address below must pont to the Scrape License Server If you we Derw a proxy EECH FOU must enter ine aoorocrfe tte mite Sytem Lett TOU may verry that ihe commuma ier a propa Garena Dy Choong ine ett Cone tion button Hito AAA ca ren rra Worm op Tit Cormac Click Test Connection button to verify connection to the server Communication Successful message appears on confirmation of the test a Communication successtul UY Interface version 2 6 3 Material Settings a In the Material Settings you can customize administrative information and settings for the shape and type of construction elements available through the applications in Dental System The customized settings ensure that the same data is used and kept unchanged in the Dental System applications In this way you save time working in DentalDesigner as values of the construction elements are loaded once and don t have to be typed in again The image illustrates the main window of this catego
101. is identical to Annotations described in Single Coping chapter Insertion Direction This stage is identical to Insertion Direction described in Single Coping chapter Margin Line This stage is identical to Margin Line described in Single Coping chapter Die Interface This stage is identical to Die Interface described in Single Coping chapter At the Design abutments step you can model abutment in two different ways 1 Using the Parametric Abutment Generation tool default which is activated deactivated from Dental System Control Panel gt System Settings The new parametric way of designing abutments offers you the ability to design Custom abutments much faster and in a more unified way The Emergence profile and Top cap design steps have been merged into one and the option to change the insertion direction of individual abutments at the Design step is made available rather than having it at the Directions step as it is done with the traditional method When using the Parametric Abutment Generation tool the stages of the Design abutment step are Parametric Sculpt and Assembly 2 Using the traditional method In this case the stages of the Design abutment step are Emergence profile Load Top cap Sculpt and Assembly If you are modeling a single custom abutment another way to select the traditional method of designing an abutment is to select Dental System 2008 instead of Dental System 2009 Both methods are described further
102. is option to quit the installation Note The backup can be retrieved automatically from a previous 2009 1 installation whereas a backup of a previous 2008 1 Dental System installation must be restored manually The Stand alone installation is recommended if the software is only going to be used from a single computer within the site The Server Client installation is recommended if the software is going to be used from more computers within the site Naturally this installation requires that the internal network within the site is configured in such a way so that the different client computers can all access the Server PC The advantages of the Server Client installation in this case are The software is only installed on a single computer making this and future upgrades and maintenance simple All the orders within the site are stored in the same shared folder and in the same database The client installations can be made on and operated from all computers within the network of the site so you are not limited to work on a specific computer 3Shape Dongle Server handles the available licenses Click one of the icons to choose the installation it will become highlighted as shown on the image above The program brings you to the second step Create backup e Create backup Please make sure no other hane software is tunning before continuing Tye a description for Un becloun Preven ut ou che a cherie that e A O ety r eee vou nod to a
103. justments to the Scan EIER Medium Largest Settings opened via File gt Scan Settings of the ScanItLibrary menu Smooth level The three tabs allow you to define General Scanner and Smooth settings Lowest Medium Highest 7 2 Adding Model to Library SES g P og St Once the settings described in the previous chapter have been made you Can add a new custom dental model to the library via the Dental System Control Panel as you need to define your new library before performing a scan 1 Select Scan Library from the File menu or click the corresponding Add ne branek in Dintil iber Control Panel al icon to open Scan Library window P i i eeren ae Tooth Derrwtre EE D f 2 Click the Add button to open Dental System Control Panel at the Libraries page ege TETE ta Gee 464 z i i Trex 3 Mier tooth D iani CO Selected cance ERARI Click Add button confirm the library Base EES Path name your model and click OK to Navigation Hume Hlalerial Settings save The created model listing should now appear in the Libraries list Prismak vi D Premam L I Prei 118 Preran Pout ergs Pram Choe Premama H ertsvn dg Premam SO Aaf Premium Triangle SLarard Frane Pot fan library Library s avadante for the foo Covers and Crown Pad Frare Porites d Deele BR rove up k Fire kg Select created model from list and specify the requir
104. l 1 Select preparations in Order details the teeth overview 2 Click the Abutment button 3 Select pontic in the teeth overview 4 Click the Frame button and select a pontic 5 Select all units in bridge in the teeth overview 6 Click the Bridge button GES d Index 26 Additional 2 2 1 14 Post amp Core Order details Index 15 Additional 1 Select preparation in the teeth overview 2 Click the Frame button and select post and core e Zr Coping tangent Abutment 2 2 1 15 Select Material and Manufacturer After you have defined your order you can click on this button to choose the material for your restoration it s db type and color as well as the manufacturer and the manufacturing process All the settings in this form are predefined in Dental System Control Panel and can be edited from there Material choose restoration material Material Manufacturing process select the set of settings for a specific machine Manufacturing process Ilan Manufacturer you can choose yourself as a manufacturer or another site manufacturer Type choose the material type Color select the material color Manufacturer Johnson Milling Type zr Coping tangent Color Al 2 2 2 Customer Information Customer information Customer Contact person Create date Shipping date Sunny Clinic Alexis 08 0
105. ld then be placed into the scanner the plate will click into the correct position inside the scanner with the help of the fixing spheres and markers on the plate Close the scanner door and click the Next button to start the overview scan The initial scan is a rough general scan of the arch cast You can now use the selection tools see image to the left to select the detailed scan area The selected area is highlighted in red Click Next to start the detailed scanning of the selected area Once the detailed scan has finished a more clearly defined 3D model is displayed on the screen At this stage you are offered to mark the dies for individual scanning Place the points with the left mouse button on the margin line on the front of the teeth as shown on the image below E Scntiiertontan e Gie Ve d SB Mark teeth D a EI E Pd a r El s e Next you are required to scan each tooth separately by inserting them into the scanner as prompted by the software dialog Insert tooth 14 Fut tt al tha centre of imerace plate CA entrees eo 3shape Once the first tooth is inserted into the scanner click the Next button to perform scanning After the scanning of an individual die has occurred a warning message may appear to indicate that the software needs some manual assistance to merge the die to the impression with the higher accuracy Place the point on a newly scanned die with the left
106. le defines the starting angle of the lingual band counting from the user defined annotation in counter clockwise direction End angle defines the end angle of the lingual band counting from the user defined annotation in counter clockwise direction Offset is the offset applied in the lingual band area Click Apply to view changes click OK to go to Sculpt 2 Anatomical coping The anatomical coping is designed from a crown outside in which means that during the modelling process you have to go through Design Anatomy step first and design a crown and then model a coping at the Design Frame step After the crown has been modelled and you appear at the Design frame step specify the settings for your coping in the Tool Forms Facial ve z e To create an Edge design for you anatomical coping define the Lingual Proximal 1 2 and Facial settings as shown on the image above left Click Initialize to view the result Click Clear to delete changes Min coping thickness is the minimum wall thickness of a coping Wall height is the distance from the margin line to the borderline marking the beginning of the area where the wall thickness is applied Anatomical offset is an internal offset from the crown outside in that actually creates your anatomical coping When you select the Remove Undercuts check box the Angle slide bar appears that lets you define an angle starting from the insertion direction obliq
107. le is shown below Measure area measures the specified area and distance Clear Measurement removes any measurements from the 2D Cross Section window Zoom All returns zoomed in out view to its original scale Grid shows hides the grid in 2D Cross Section window 5 4 2 Distance Measurements The distance measurement tools are simple and effective instruments providing you with different distance measurements on the screen These tools are located in the Main toolbar as shown on the following images The three types of distance measurements are as follows Distance to Adjacent Distance to Preparation Scan and Distance to Antagonist Scan In order to work with the measurements click the button for the required type of measurement and indicate the point of interest with the cursor All three types of measurements can be enabled at the same time and distinguished by the measurement color The illustrations of measurements given below are self explanatory Distance to Adjacent colored blue Distance to Preparation Scan colored red AMAS San AD Distance to Antagonist Scan colored green ae e x 5 4 3 Validation gt bo d Validation Update Automatically Apply Material Settings Thickness 0 680 mm rea 10 00 mm Strength 0 01 mm Update The Validation function tests the restoration model against the values pre set in Dental System Control
108. lected order An example of the window is shown below Track and trace lines for the selected orderfmodel Order number 20090908_1500_Tech_01 Date Expected receive date Comments The order has been shipped and dosed ItemID MEI 4512610248598 3 lt none gt 32 41 The order has been accepted for production ItemID MEID 4512610248598 2 lt none gt 32 41 Order received by manufacturer inbox ItemID MEID 4512610248598 2 lt none gt 32 41 La 03 09 2009 14 47 06 16 09 2009 La 08 09 2009 14 43 50 16 09 2009 La 08 09 2009 14 43 12 La 08 09 2009 15 34 31 Model uploaded to Bradford Milling For the feature to work it is necessary to have read and write access to the FTP directory since the track and trace information is uploaded to and downloaded from the FTP server Different FTP servers have different requirements for FTP directories e g some require at the end of the directory whereas others do not In case of doubt please consult the corresponding manufacturing site for proper settings 2 6 4 Re Sending Orders With 3Shape Dental System software you can share the whole process among a few sites For example you have the possibility of creating and scanning orders at site 1 designing orders at site 2 and manufacturing them at site 3 The possibility is given with the Inbox Add on Module where the orders are shared between involved parties 3 Scanning Models ScanItRestoration The ScanItRestoration mod
109. lick Clear spline to start over Show top cap angle shows the angular value between the implant insertion direction red arrow and the vertical top cap direction green arrow Show top cap undercuts visualizes the undercuts on the design model Collisions between models warns you with the Collisions message in case there are collisions between the top cap and other models No collisions message informs that no collisions were detected The Undo and Redo buttons are used to cancel or reapply the last actions made The Undo All button deletes all the changes made Click Apply to view the changes Click OK to go to Sculpt and Assembly steps Screw retained crowns are also supported by the system see image to the left When on the Save step the Screw retained crowns check box can be selected In that case the anatomy is brought together with the customized abutment and the system automatically makes a hole through the upper anatomy so that the entire restoration can be fixed to the implant via a screw 5 2 2 13 Implant Bars and Bridges Implant Bars Annotations This stage is identical to Annotations described in Single Coping chapter Insertion Direction This stage is identical to Insertion Direction described in Single Coping chapter Parametric This stage is identical to Parametric described in Customized Abutments chapter Sculpt This stage is identical to Scu pt described in Single Coping chapter Ass
110. line and Die interface will be reflected in the Process Toolbar and so on 5 1 1 5 Tool Forms Points Edit points cesar Insertion direction ya er e ue yy Approximate height 8 89 mm A SE 2 gt Difference map Coloring Undercut area Measure undercuts Sculpt toolkit Wax knife settings e Las O 2 16 mm a g 0 56 Gllstalalslel i SR Go Each specific stage in the Process Toolbar has its sets of tools that become available when you click on the stage or it gets activated automatically These tools are displayed in the Tool Forms in the left bottom part of the window For example if you are at Directions step of the modelling process and working on the Insertion Direction of your model a special window is displayed in the Tool Forms that helps you set a correct insertion direction see image to the left When you are for instance at the Design frame step you can select the Sculpt toolkit to modify and transform your model as desired see image to the right You will learn more about all these tools and toolbars from the next chapters during the modelling process 5 1 2 Model Visibility The Model Visibility slide bars appear in the upper right corner of the modelling window and you can enable disable them by clicking the corresponding button Get in the Visualization toolbar as shown on the image These slide bars enable you to change the models translucency they he
111. list view can be sorted for a specific column by clicking on the column headers The order of the column headers can also be changed Click on the heading you want to move and drag it to the desired position To customize the columns show hide them in the window right click on any column and select unselect the desired ones Number Creation date Shipping date Delivery date Client 0 20090908_1427_Tech_01 5 9 2009 2 47 23 972142009 9 8 2009 Bolton Lab y 20090908_1449 Tech_01_John Peterson del 2009 2 52 38 5116 2009 9 16 2009 Smile Dental wm 20090908_1500_Tech_01 9 8 2009 3 13 00 oner 9 16 2009 Smile Dental PM To select multiple orders hold down Ctrl or Shift and choose the orders you need Then use the buttons in the Main toolbar or right click on the selection for further handling d1000_200906 Orders that are not finished before expected delivery date are marked with the sign created Order Status order status icons change according to the stage of the order processing _ oe Modelled Y Closed Y Accepted Information on the Selected Item the information on any order or item you have selected is shown in this window 3D Preview a 3D preview of the scan and design of the selected order is displayed here Click on the scan in the preview and rotate it with the mouse You can also zoom in and out If the order was created but has not been scanned yet you can see the preview of your order as shown in the image at the
112. ll characters where spacing strinc Crder ID template field 9 Unspecified e using MIS characters where spacing strinc Crder ID template field 10 Unspecified o using MIS characters where spacing strinc Crder ID template field 11 Unspecified sl using characters where spacing strinc Internet Connection If a proxy server is used at the current site the Use proxy check box is selected then you should specify the proxy settings in the corresponding fields Internet connection STOTIGz y 3128 e e a a Miscellaneous A Enalish ll Universal Numeric Notation gt m E Ges Pl Choose In the Language combo box you can choose between the available languages for all applications This selection will also affect which user manual is opened to the user In the Tooth index system combo box you can specify the type of notation to be displayed in all applications in the Dental System The Background Color allows you to define the background color in ScanItRestoration and DentalDesigner 6 2 3Shape Dongle Service Select Open dongle in 3Shape Dongle Service link in the main Control Panel window to open the page with the Dongle Update and Connection Setup options as shown on the image kt Dental Sorter Control Panel Dongle Update si feel Kl Save CA Beck Hansi Homee eg HE te B Denia Dene 1 chen ports Denisas 3 cent Geste Detalla Sieg modus 20 chert pints FOOT Scant
113. lp you view the model and its parts from different angles as well as displaying additional information such as collision lines Depending on a model a step within the modelling process and settings in the Order Form the number and appearance of the Model Visibility slide bars can change Some of the slide bars need to be activated by clicking on the dots located next to them the dots become black when activated To adjust visibility left click on the icon and drag it to the left or to the right The image below illustrates the 3 unit bridge at the Design step you can see the Model Visibility slide bars in the right corner The table below describes most of the DentalDesigner Model Visibility slide bars Preparation makes the preparation scan more less translucent Antagonist makes the antagonist more less translucent th Cut neighbors when active cuts the neighbors of the model so you can see it from the sides when rotating y Inactive items makes the items that are not modelled at the moment more less translucent Active item makes the item that is modelled at this point more less translucent Collision lines shows the collision points of the model with neighbors and or antagonist Undercuts makes the undercuts more less translucent Ou Thickness map provides the information in colors on thickness of the model Distance map provides the information in colors on distance of the model t
114. m to form a shape you need Do the same with the central points if you need to move them The points become yellow when activated The changes are immediately reflected in the modelling window View the 2D cross section of the connector for more precision the location of the plane that cuts the connector to display the 2D view can be changed using the Intersection slide bar in the Connector Settings When you are done modelling connector on one side click OP or COPY ro apply the same changes to the other side of a connector Click Reset or Reset All to cancel the changes and click Apply to implement them Click OK to finish editing connectors Click Next to move to Finalize step 5 2 2 3 Full Anatomical Crown Annotations This stage is identical to Annotations described in Single Coping chapter Insertion Direction This stage is identical to Insertion Direction described in Single Coping chapter Margin Line This stage is identical to Margin Line described in Single Coping chapter Die Interface This stage is identical to Die Interface described in Single Coping chapter Crown When you proceed to the Anatomy design stage DentalDesigner automatically places crowns and pontics but you can always modify them as desired Click on Crown in the Process toolbar to modify crown s Two EI ES A You can load different crown models out of the extended Anatomy library In addition Contact points you can click Browse to pick
115. margin line of the model at the Insertion direction stage The Margin Line stage then automatically places the red spline based on these points The margin line is extracted based on the red pencil margin line approach which simulates the manual approach used by many technicians Note It is recommended to visually inspect the automatically detected margin line and if needed to modify it using the Fast edit functionality By using the mouse cursor to draw or simply click on the model you can modify the margin line easily As described below there are other ways of modifying or adding a margin line but the Fast edit functionality is in general the preferred method If for some reason the margin line can not be automatically placed the program will ask you to place it manually Place the margin line by left clicking on the model and placing the points until the full circle is formed The points on the line can be visualized if you check the Show points check box in the Tool Forms to view the undercuts areas check Show undercuts The points turn red they are blue initially when they are in the undercut areas to draw your attention to this potential problem Hep Amai Ce Bee urd its Than puerta d ven z KIEREN Dax ee ange om Berton gp 14 Papa ered T Zug angie i aa Cred ated PE A Be Cen Eege 34 E a Se s i The individual points can be moved either manually or using the Step button When the Step button is pressed
116. mouse button and then the second point on the corresponding location on a scan the points should be placed in approximately the same area of the die Once scanning and saving is finished you can go straight to the modeling procedure by clicking the Design button or you can opt to trim preparation or pre preparation scan first When required you can redo single scan operations initiating them with a click on overview window 3 2 3 Full Anatomical Crown A full anatomical crown scanning is identical to the bridge framework scan please see section Bridge Framework for details 3 2 4 Full Anatomical Bridge A full anatomical bridge scanning is identical to the bridge framework scan please see section Bridge Framework for details 3 2 5 Anatomical Copings and Framework The anatomical copings and framework scanning is identical to the bridge framework scan please see section Bridge Framework for details 3 2 6 Inlay Inlay Bridge An inlay inlay bridge scanning is identical to the framework bridge scan so please see section Bridge Framework for details 3 2 7 Onlay Veneers The onlay veneers scanning is identical to the bridge framework scan please see section Bridge Framework for details 3 2 8 Over pressed Crowns and Bridges The over pressed crowns and bridges scanning is identical to the bridge framework scan so please see section Bridge Framework for details 3 2 9 Single Wax up Before scanning a wax up and a d
117. n directly to production When the manufacturer receives an order the create delivery dates are set automatically depending on the Dental System Control Panel settings DSCP gt DentalManager gt ERP and processing time It is also possible to change set the dates manually The orders should be closed when their processing is finished Fa ree riche An Auge Aa a ERA Sat TEE 1454141158 12 18 Zeie he wma 4 p w i ER 8 22 i Lag er zen Are Tech p1 paa feel a onse gy LS 2009 Bradford M ng Abri Eran Accepted 765mm e Gets Sr 020 Pensar Pht D Mm dass Sry ks airy bade Wi ron Oral f Dote ZE APN E ong dE Srde Dental SET H GOWN we Den Modeled 7 51 mms agp Medi Cel A Bow 014 IS Tech DI 12009 aarm Code Denial Tipe LG ken Parei Hi i E EE S be Model Cale dok sie i en EEE A9 d Check Out Cratet 12005 9 15 3009 habr Milling Absent gt Zeie carre Moses 2000051 _ 1756 700 0 E Preview Celw Ve 9 15 2009 Enge Dental Coprg 2 Tren beamed Ka Delete If for some reason the order is rejected ei the customer gets a note in the list view 2 6 3 Track and Trace Information between Lab and Manufacturing Center Track and Trace Ctrl R It is possible to follow the status of the orders by utilizing the Track and Trace function Right click the order of interest in the Order list and select Send gt Track and Trace from the appeared menu Track and Trace for Selected Orders window opens up displaying the status of the se
118. n is to ditch the dies A margin line must be defined for each preparation Click a point on the top of the displayed tooth the software will automatically find the margin which can be edited as usual Alternatively the margin can be drawn by dragging the mouse Click Next to continue Note 3Shape highly recommends that the dentist prepares using an exposed margin A8 Virtual Model Design Bhar Dard DEA ar Z gi F ee E Dm The Removal radius is the radius of the virtual burr used to remove gingival tissue from the surrounding model around the margin line Set the required insertion direction for the tooth with the virtual joystick as shown on the image below You can also rotate the die with the cursor and press the Set pin direction button to redefine the current point of view as the insertion direction Click Next to continue Ss ee rs a El Ges ep a AS Virtual Model Design Dep Jo 4 Diii pau A shape Adjust the position of the platform with the articulator interface The position is changed by holding the mouse down over the blue articulator interface and dragging The Articulator drop down menu allows you to select different articulator interfaces Simple Quadrant Simple Full Arch and Base Click the Next button to continue A Virtual Model Design Siep 4 of d Articuno Wiere tne Leg Che pexge fo poet Ge Cleo meo the dened poah 3shape The virtual model design
119. n scanned and aligned one by one the scanning process is over and your model is saved Scanning and Saving finished Click on pendew window to rado singla tran operation be 3 POOR fe 3 d CG w Click on the Trim preparation scan button if your final model needs to be trimmed If you need to re scan or realign the die you can click on the desired tooth in the Overview map and select the Scan tooth or Align tooth button You can also view the Difference map if desired If you are satisfied with the result and want to start the modeling process in DentalDesigner click the Design button It is not necessary to close down ScanltRestoration after each scanning process 3 2 17 Pre preparation The pre preparation model and diagnostic wax up can now be scanned and aligned to the normal preparation scan and visualized during the design phase If pre preparation scan is required select the corresponding check box in the Order form Scan settings tab and create the order as usual Having completed defining new order 1 Click Scan button to proceed to the scanning step Insert pre preparation arch Back Net 2 This opens Scanlt Restoration window asking you to insert pre preparation arch EH S o 3 Previously created orders i sent to scanning with the Next or Scan options available from the right click menu on one of the created orders listed within DentalManager 4
120. n to initiate the scanning process preparation side up A fast overview scan is performed and on the screen The application asks you to mark the teeth included in your order Select each preparation individually and click Continue between each one Next you are prompted to mark the region of interest as shown on the image below This is the region containing all preparations and any desired adjacent teeth Click Continue when done On completion of the process all models become saved and you can then do optional corrections if needed Scanning complete All models have been Saved Drk Hpi i arg h H inir nmp tE J 500000 FP yee oe 3 i F bs va VW Si AA Te et impreso inte gt PCA Popes Orbe PALO Lt Tiras i ESELA 108 Thami Hr ean sall Els Vo Feb Remove Artefacts preparation side CiRecnsvetrtet arts pte ieee Setiings E Tonka lectora db f Che Aduana ed E Dep Baba F Click Next to go to the Virtual Model Design step and do trimming of the model EI 50005 4 4 2 Virtual Model Design Once trimming of the model has been performed click OK to continue SB Virtual Model Design Step l ofa THe Pde beg Hace An w i SL Patient Dres ae ee The Add Remove material stage is an optional stage that can be used to modify the impression e g correct flaws in the preparation or remove gum tissue The next virtual modeling operatio
121. ne 3 E and Width scaling for the specific cross section which turns yellow when active Active cross section Click Apply to view the changes Click OK to move to the Finalize step where you can use the Sculpt Abutments tool to make some final changes in the restoration please Width scaling 1 00 SS see Sculpt section for more information CUE Distance to spline 0 50 mm 5 2 3 Finalize Step e After you have completed one of the Design steps click Next to go to the Finalize M step The program allows you to view the final result of your modelling and make additional changes if needed The images below illustrate the initial model and the final result of the Finalize step Sculpt toolkit The Finalize step offers you the Sculpt toolkit to edit your restoration This tool is the same as in the Design step except for the Global transformations button which is not available here Please see chapter Sculpt for a detailed description of this toolkit Morphing settings Note Whereas in the previous steps you could only work with one O me 1 68 mm item at the time this step allows you to edit all items of the restoration at once Click OK to finish editing Click Next to go to the Save step 5 2 4 Save Step Ka Defined items When you go to Save gt step the program automatically saves your model You can of coping 30 view a list of items that have been modelled in the Process toolbar see image to the of crown 30 lef
122. ng WaxupOverlay Ti MM Active model Active cut spline Waxup 11 ent Active connector plane 4 Le e Advanced settings A Bridge offset 0 70 SS mm Min wall thickness 0 40 mm Smoothing 0 0 Cut offset 0 74 2 mm Margin line offset 0 10 amp mm Offset angle 1 65 0 3 gt Extension offset 0 10 mm Lingual band Apply WM Start angle 179 End angle 240 a Offset 1 00 mm When you model a wax up bridge in DentalDesigner at the Design frame step the program automatically places a wax up bridge scan over the preparation scan and provides you with the necessary settings for further modelling Active cut spline arrows help you navigate between the wax ups making one cut spline active green at a time so you can easily edit it The cut spline is used for cutting the scanned wax up the part above this spline is used when designing the wax up model The Reinitialize active cut spline button places the active cut spline in the initial position The Check cut splines button validates the positioned cut splines and informs you if there is a problem e g there appears a message Spline does not lie on the model surface please reposition the spline The default placement of the cut spline can always be edited with the help of a Fast edit functionality which when activated lets you easily draw or click on the model for a quick and easy editing Active connector plane arrows help you navigate between the connectors making
123. ng and it should be secured so that it will not move during scanning When the fixture is inserted into the scanner the strings on the fixture should be approximately parallel to the front wall of the scanner Insert wax up bridge rn StH etree eo Then click Next button to scan wax up bridge i Peeper 2203 1005 Tech BL SB Wax up bridge Anas lacking scan data ane martasi Oplon lly Supbl in nt Ae St ap Cae D part nreed In he nest Heg SStQlewres soono A scan of wax up bridge has been received In a case when scan data is lacking for some areas they are marked in orange color A supplementary scan can be performed to reduce blind spots Click Next to continue and make a selection whether you want to perform supplementary scan before going to the next step te Den Align wax up bridge all Sekt bra read pd Loge or mach Eege algo Click Apply button to execute alignment as shown on the image below e 3B Align wax up bridge Sepals Le IL ss Click OK to go to the teeth scanning step 3shape etme ODO i Do sg i eiei HOGA Rz Fa D 1 e D At teeth scanning step the teeth are placed in scanner and scanned one by one in a defined order amie al OB Insert tooth 24 Put H o the cortro of intortace plato ea mg H Ke 60060 3shape At the last step the scanning is
124. nment of the scans will not be successful Remove additional mm teeth from arch a f a d E E S S ep e i hy b 9 3shape After the preparation has been scanned you will be asked to mark the teeth with the annotation points and then insert the separate dies one by one for scanning Mark teeth OO kl 24 dat After the first required die has been scanned the program will automatically align it with the preparation In some cases ScanItRestoration might ask you to do the manual alignment Align tooth 22 ee E You can perform the alignment using two points or three points for the latter select the 3 point alignment check box The points should be placed on each model in approximately the same spots Click Apply to view changes see image to the left click Reset to start over If the manual alignment has been performed poorly you will get the warning window as shown below Click Retry recommended for realignment click OK to accept it not advisable If the manual alignment has been performed poorly you will O Warning tooth alignment has relatively big error Click on OK to accept it otherwise click on Retry recommended get the wa rning window as shown below Click Retry recommended for realignment click OK to accept it not advisable After all the dies have bee
125. ntgap 0 085 mm Dist to margin line 1 00 E mm Smooth dist 0 20 WW mm Dril radius 0 65 2 mm Dril Comp Offset 0 66 mm le Order Frame bridge 2 4 a Apply Clinic Sunny Clinic Elements in the Name drop down menu are used for creating the interface Each element corresponds to the material specified in Dental System Control Panel and selected in the Order Form thus users can build up a list of preferred settings using this application Undercut areas are often compensated for to make it possible to insert the restoration onto the dies There may also be production issues having undercuts in the final models The undercuts are removed by checking the Remove undercuts check box The effect is illustrated in images below e 1 Undercut 1 Undercut removed 2 Insertion direction 2 Insertion direction If a milling machine is used for production it might be necessary to use the Drill compensation function This compensation adds additional offset to the interface in areas having too high curvature compared to the radius of the applied drill tool This ensures that milling of the interface is possible which in turn guarantees a better fit to the final manufactured restoration The amount of offset can be visualized using the buttons in the Difference map settings To view the difference between the offset model and the scanned reference model select the Thickness button The die interface becomes colored accordingly
126. o the antagonist and neighbors T e pe Scan Abutment makes the scan abutment more less translucent Implant makes the implant more less translucent Interface makes the abutment interface more less translucent Base makes the abutment base more less translucent Screw makes the abutment screw more less translucent Pre preparation Double preparation makes pre preparation and double preparation scans more less translucent Wax up bridge makes the scan of a wax up bridge more less translucent Face scan makes the face scan more less translucent 5 2 Modeling Steps 1 Order 0 gt El 2 Directions 3 Interfaces 4 Design Design Abutments Design Telescopes Design Anatomy Design Frame NN R A R 5 Finalize 6 Save The DentaDesigner modelling process is split into 6 main steps as illustrated in the table to the left These steps are organized in the Main toolbar When you complete one step you are allowed to proceed to the next one or return to the previous step OK You can go to the next step by clicking the button that CA Finish appears in the Tool Forms or the Process toolbar s ez Use the buttons to go back and forth from one step to another To go to the next stage step of the modelling process click F6 it works as both OK and Next buttons button that appears in the The following image illustrates the stage you are currently working on You c
127. of the top When no smoothness is applied Min wall thickness 0 40 amp mm the lines follow the surface of the basis coping Wall height 1 00 mm e The Min height parameter shows the current minimum telescope cone height defined as the minimum distance between the upper and lower Margin line offset 0 10 e mm control points When changing the value the current upper control points Offsetangle 1 65 00 B will be moved up or down to adjust to the new height Extension offset 0 10 mm Lingual band Apply Y EE Sr Hint To obtain the maximum height write a very large number End angle 360 Se and the upper control points will be moved as high as possible Offset 1 00 mm Primary crown settings A e When selecting the Prep line shape checkbox the upper control points a SE are initialized to have the approximate shape of the margin line e l e Specify the desired distance between the points using the Point distance Smooth LI 1 00 parameter Ea e To initialize all control points press the Initialize button Telescope spline control Min height 3 08 2 mm e For a fast preview of the final telescope surface shape press the Preview Se SS button The telescope surface will then be visualized as it would look upon Prep line shape completion Point distance 0 75 E mm _J pl Press Apply to generate the complete primary telescope or click OK to finish Preview Initialize Rm Optinal Components The next stage Optional component
128. ogin and Password The database connection can be verified by clicking the Test connection button A green check mark appears next to the button in case of a successful connection Selecting the Show limited number of orders check box allows to define the default number of visible orders A smaller amount of the displayed orders improves the overall performance of the application Specify the Number of visible orders in the provided field Send options If Send Patient Name check box is selected the name of a patient is sent to the manufacturer together with an order If not then the patient name is removed from the sent order file Order import When a dental lab sends an order to the central manufacturing center the manufacturing center has ideally already exported its material settings to the lab please see Sites chapter for more information In this case the lab can create an order which matches the manufacturer center settings e g with regards to materials manufacturing processes coping thickness etc However if the order sent from the lab is not based on the materials imported from the manufacturer center then the manufacturer needs to perform Import material mapping when the order arrives at the 3Shape DentalManager Inbox This means the manufacturer needs to define for instance which of his own materials corresponds to the material defined at the lab This mapping is stored so the manufacturer does not need to do the same m
129. ompleted defining a new order click Scan button to proceed to the scanning step This opens ScanItRestoration window asking you to insert arch and wax up bridge Previously created orders can be sent to scanning with the Next or Scan options available from the right click menu on one of the created orders listed within DentalManager Click Next button to scan arch and wax up bridge together Insert arch and wax up bridge Friant dita faces ihe buide of hae me eye goe ie E k gt DP Remove waxup bridge mm Do not move arch D l P R eN Di EI di a Es K RK Wis rb d 3shape gt Mark the teeth accordingly at the next step and click OK to continue SSP etree Emer Chad CS ho cord r t Ba miSa ts Eh paris Remove arch and insert a wax up bridge You should mount the wax up bridge on the specially designed fixture view this fixture with a bridge on the image below Since the wax up bridge often needs to be painted before scanning it is important to ensure that the strings of the fixture are not polluted by the paint The wax up bridge should be mounted so that the important part e g the front side of the teeth is well visible for the cameras and laser in order to obtain optimal scanning coverage Typically invisible surfaces face downwards The wax up bridge should not be placed too high on the fixture preferably not higher than the second highest stri
130. onality allows you to scan one preparation twice where the first scan contains some extra features e g markers to aid later positioning additional teeth etc and the second scan is the preparation itself If Double preparation scan is required select the corresponding check box in the Order form Scan settings tab and create the order as usual The created order appears in the DentalManager order list Select you order and start ScanItRestoration by clicking Next or Scan You can also start ScanItRestoration directly from the Order form by clicking the Scan button When the program opens up insert double preparation arch into the scanner The scanning process will start when you click the Next button insert double preparation arch E GE E E A T ein H Ah g ny e gt CH Ko e hu DN CR te 3shape is After the scanning process has been completed the program will offer you to trim the scan Pick one of the selection tools and trim your double preparation scan by selecting the desired part and clicking Apply or OK A8 Trim double Pa preparation scan D E la BET nl a El te Ae tir a E oy E E E e H EN e E e E 12 ao a telertian Teala D a a a Caras Le 11 toe Carefully remove the additional information e g teeth from the arch so that the preparation could be scanned separately Caution Do not move the arch If the position of the arch has been changed the alig
131. one connector plane active at a time The Bridge Offset is the outer wax up bridge surface offset parameter which allows a modeled wax up bridge to be offset inwards to make room for ceramics The Smoothing parameter lets you change the smoothness of the wax up surface The Cut offset is the distance between the margin line and the cut spline The rest of the settings are similar to the standard coping please see Coping section of the Single Coping chapter for more details Click Apply to view the changes Click OK to go from the Wax up bridge stage to the Sculpt stage Sculpt This stage is identical to Sculpt described in Single Coping chapter 5 2 2 11 Telescope Annotations This stage is identical to Annotations described in Single Coping chapter Insertion Direction This stage is identical to Insertion Direction described in Single Coping chapter Margin Line This stage is identical to Margin Line described in Single Coping chapter Die Interface This stage is identical to Die Interface described in Single Coping chapter At the Design telescopes H which consists of Primary telescope overlay Optional components and Sculpt stages the telescope is modelled The images below illustrate the initial model and the final result of the Design telescopes step see the following sections for more information Telescope Direction Telescope direction is only active when you are modeling a telescope If there is mor
132. or 3 points alignment method click Apply button SB Align upper and lower arches to preparation arch Ri Example of aligned upper and lower arches to preparation arch is shown below o A my ee Aas 2 2p D Align upper and lower arches to preparation arch StH eure sogad At the next step you are required to align antagonist arch to the model using either one or 3 points alignment method click Apply button Ela E Align antagonist arch Ste eure BBD vunn 7 Pett takt A RA mala Arer geet Bora la e Example of aligned antagonist arch to a model is shown below 5 Align antagonist arch HJ eire OIR D ihe KK Then you are required to scan each tooth separately by inserting them into the scanner as prompted by the software dialog Insert tooth 14 Pat ii al ihe cenir of terface plate a IJ wa e A is o s si 6 a the ue i ey E 0 OOP Once scanning and saving is finished you can go straight to the modeling procedure by clicking the Design button or you can opt to trim the preparation scan first When required you can redo single scan operations initiating them with a click on overview window Co Hee x Scanning and Saving finished E Ir A wee A can Operations ad anem a E ef R Toi v d 3shape 3 2 16 Double Preparation The Double preparation scan functi
133. orresponding points one on the CAD model and the other on the scanned abutment and click Apply button The result of alignment will be displayed on the screen The images below illustrate the alignment process Click OK if the result is satisfying and align the next abutment the same way Once abutment alignment is finished you will be prompted by the confirmation window asking if you want to scan the gingival mask When you click on Yes recommended the program will ask you to remove the abutments from the arch and insert the gingival mask Similar to bridge scanning you should select the area for detailed scanning after a rough scan At the final step you can trim your preparation scan Trim preparation scan button or realign abutment scan For realignment click on the desired tooth in the Overview toolbar and select the Align for abutment button that appears on the screen oos e Kl OF 3shape gt 4 Click the Design button to start the modeling process in DentalDesigner It is not necessary to close down ScanItRestoration after each scanning process 3 2 13 Implant Bars and Bridges The implant bars and bridges scanning is identical to the customized abutments scan please see section Customized abutments for details 3 2 14 Antagonist Bite A bite scan can be used for visualization purposes A scan of the bite mounted on the cast can be used in DentalDesigner to assist with the sizing of restorations Once an ord
134. pears on the screen DentalDesigner user interface comprises the following toolbars Your order is displayed in the Modelling window where you are able to view and model your order throughout the whole process 1 Overview toolbar 2 Process toolbar 3 Tool forms 4 Modeling window 5 Main toolbar 6 Visualization toolbar PERE goe 5 1 1 Toolbars This section contains detailed information on the toolbars with DentalDesigner interface Main Toolbar Visualization Toolbar Overview Toolbar Process Toolbar Tool Forms 5 1 1 1 Main Toolbar The Main Toolbar contains some of the major functions for performing the modelling process The table below briefly describes the name and functionality of every button of this toolbar New modelling starts a new modelling session note that this button is not used when started from DentalManager h used when started from DentalManager Save modelling saves the current modelling session to a file Order brings you to the step where the order form can be accessed crowns E Open modelling loads a previously created modelling session from file note that this button is not Auto update connectors automatically updates connectors when bridge elements are edited Measure distance to adjacent measures distance to the adjacent tooth teeth Measure distance to preparation scan measures distance to preparation scan Measure distance to antagonist scan mea
135. pendent of the user point of view Show annotations displays annotations on the model Material shaders marks the 3D model parts with the corresponding colors imitating the surface of the real restoration materials oh 5 1 1 3 Overview Toolbar The Overview Toolbar is designed to quickly provide information on the current job It enables P F e An overview of the modelling jobs specified in the order form as well as 4 e i N information on the currently active job highlighted with green dots ke br e Information on job names and tooth numbering when you pause the WI mouse over the item e Activation and switching among jobs by left clicking on the corresponding item e e The visibility of scans and restorations by right clicking on the he corresponding item P gt B gt ER WI 5 1 1 4 Process Toolbar Directions Next Se a Su dy Sy Raf A aqua F A Insertion direction a Frame bridge 2 4 There are 6 main steps in the modeling process Order Directions Interfaces Design Finalize and Save please see chapter Modeling steps for more details Each of these steps includes a number of specific actions which are displayed in the Process Toolbar The image to the left shows an example of the Directions step In this case the Process Toolbar reflects its two stages Annotations and Insertion direction If you go to the Interfaces step for instance Remove artefacts Margin
136. port M Test connection The Inbox folder path defines where the orders downloaded from FTP are stored before they are inserted into the DentalManager system This folder is common for all FTP servers Note that you must have read and write access to the Inbox folder Set the FTP settings according to the actual FTP server the URL can be specified either as shown in the image above or by using the IP address When this is done the connection may be verified by clicking Test connection button 7 Custom Libraries ScanItLibrary ScanItLibrary module allows adding custom libraries to the available standard ones In this chapter you will learn how to define scan and save your own dental models e g crowns pontics etc The ScanItLibrary module is started from the icon in DentalManager Le or via the program menu The image below shows the ScanItLibrary interface layout and the view of the expanded File and Help menus emm 1 Scan library File Help e 2 Open library 3 Visualization toolbar el Scan Settings Ctri E User manual et Send bug report About ee GOGmme 7 1 ScanItLibrary Settings General Save Save type Max no of triangles ip address 127 0 0 1 Add scanner to list Scanning height From top Remove current scanner From list Close bottom 1 Select your scanner 2 Fill in your scanner s name location click Add to save Edge length 7 Before performing a scan make the necessary ad
137. processing time Coping r Coping Ti Bridge Zr 3 unit Bridge Zr 6 unit Waxup Zr Wiaxup bridge Zr 6 unit ID 45126 JobTypeERPInftormationl Change ID Mame Coping zr Job type Coping Abutment Material zirkon Maximum number of items 1 ERF Item 100110 F Add Number of working days 2 Aja Copy Closing time 16 00 00 A Delete 6 5 3 Working Days For your convenience the configuration of the processing times and delivery dates is possible ak Specify the number of days for Default shipping time and Manufacturing Processing and Shipping time LaF Click on dates in the calender to mark them as working days weekends or annual holidays spiember 405 Mon Tue Wed Thu Em Eu Sun 1 A 5 8 d 7 10 11 L 14 15 18 LI 1 14 j kb a a a cd Lh i L Ki H Pai i HM 6 5 4 Manufacturing Inbox The DentalManager Inbox Module supports multiple FTP servers for high load central production The module allows handling orders created and sent from customers In order for the Inbox to function an operational FTP server must be available When you go to Manufacturing Inbox the window as shown in Figure below is displayed The Inbox Auto Accept check box defines whether to accept files to Inbox automatically or not Click on FTP settings to access the Inbox FTP settings window Change ID C 3Shape Inbox Browse 192 168 1 70 37 21 anonymous UU Anonymous Inboxl Mo TLS Sup
138. pter Edit Connector This stage is identical to Edit Connector described in Bridge Framework chapter Sculpt This stage is identical to Scu pt described in Single Coping chapter Split files This stage is identical to Split Files described in Full Anatomical Bridge chapter 5 2 2 9 Single Wax up Annotations This stage is identical to Annotations described in Single Coping chapter Insertion Direction This stage is identical to Insertion Direction described in Single Coping chapter Margin Line This stage is identical to Margin Line described in Single Coping chapter Die Interface This stage is identical to Die Interface described in Single Coping chapter Wax up A wax up can be both a part of a bridge restoration and an individual item All wax ups have similar default settings during an operation The wax up stage connects a previously scanned wax up with a modelled interface Advanced settings S Click the Wax up button in the Process toolbar A dialog box appears see image to Wall thickness 0 40 ge men the left Warp offset 0 6 ME rn Select an element in the Coping drop down box for the settings used in creating Cut offset 00 mm the outside of the wax up Margn ke offset 0 0 mm The advanced settings define the shape of the overlay Offset angle 51 6 0 The Wall thickness is the minimal wall thickness allowed This parameter is useful Extension offe 0 10 mm ee i Ee to ensure a minimum thickness when
139. quipment With the launch of ScanServer either through the desktop icon or from DentalManager an icon with a flashing green light appears in the system tray When this green light becomes steady the ScanServer is ready for operation o Launch the ScanServer application only after having plugged the scanner to the scan server PC and switching the scanner ON otherwise the following error message will pop up No scanner is connected to the PC by USB Please check the power and USB cable and try again 1 3 Scanner Calibration By calibrating the scanner the internal scanner geometry and camera parameters are calculated It is recommended to calibrate the scanner each time it is moved or at least twice a week However if the scanner is placed on a stable table and at a constant temperature the calibration intervals can be increased A calibration is always required when a scanner is first unpacked An indication of a poorly calibrated scanner is a scanned model with a rough surface When this happens check if it is a recurrent problem as it might be attributed to the object not properly placed on the fixture or the fixture is not firmly fixed to the black interface plate Try scanning different objects and in particular objects of different materials If the problem persists please contact your 3Shape re seller s customer support No other maintenance besides calibration is required for the scanner Caution Beware that the scanne
140. r From list Remove E AL S Custom settings Adaptive scan iterations 4ntag adaptive scan iterations Pre preparation model General Keep raw scan data when checked saves the raw scan files that can be used for reopening and editing saved orders Scanners Fill in your scanner s name location in the Add scanner to list field click Add to save or select the required scanner from the Current scanner drop down menu Click Remove to remove the current scanner from the list In most cases the default This computer is the correct setting Only in rare cases will the user want to scan on another PC Custom Adaptive scan iterations the number of scan iterations for the preparation side Antag adaptive scan iterations the number of scan iterations for the antagonist Pre preparation model when checked flips model after scanning rtual Trimming Preferences If necessary you can modify Virtual Trim Settings accessed via the File ea le lt lt menu Environment Parameters E Pin Height the height of the pin below the die CAD Models Input Directory A E Artificial Surface depth a distance from the margin line at which the gt preparation model meets the die Impression models output Directory Margin Line Angle an angle of a slope down to the margin line Cu3shapel Order 20090918 1407 Thomas HageniPblor Browse Slope height a distance from the margin line to the pin eg Pin sp
141. r is a precision mechanical device sensitive to temperature and power variations as well as vibrations The calibration is performed using the dot plate calibration object and the square calibration object supplied with your scanner see images below The procedure is simple and nearly completely automatic 1 Click on the ScanServer icon in the system tray and the ScanServer window will pop up Press Calibrate scanner button on the ScanServer window in the lower right part of the screen You will be prompted for a password which is docal The reason for the password is to keep unauthorized personnel from trying to calibrate the scanner 2 Anew window opens Follow the detailed instructions in this window which will guide you through the full calibration process Calibration square Calibration dot plate 1 4 Scanner Transportation If the scanner needs to be transported to a different site it is important that original packaging materials and boxes are used to avoid damage to the scanner during transportation 1 4 1 Transportation of D700 and D640 Please follow the steps below to perform a successful transportation 1 Switch off the PC and disconnect the scanner 2 Fasten the swing axis using the protection foam 3 Place the scanner into the original box using the original foam shape a The scanner is packed correctly The swing axis foam is packed correctly Caution The
142. re described in the manual is covered by the Terms and Conditions according to the End User License Agreement issued either by 3Shape A S or by 3Shape A S Partner from whom you have acquired the Partner version software Should you have questions regarding the content of a particular software version or system configuration please contact your local 3Shape solution provide Table of Contents eg le TEE 1 eet e E 2 Pot Rn tee Ndanda Ee CHE Lei OF D O O E 4 dz SCAMS CIV EL ds 5 EEGENEN 5 Ar Scanner EES EINEN nata a 6 b4 LEE EREM le EE iaa bobada iii 6 1 42 Transportation Or D250 atlas dalla 7 scht User Interface nc 8 E En e RE 9 Zabel le Te et Order Detall Sa EE 10 e e SIM le CODING E 11 2i Dis EN gelen TEE 12 A E Eege Mila ee e EE 12 2022 he SPO ANAC cn Cal BIG EE 13 2 21 25 Anatomical Copings and Framework EE 13 220156 INlay INlay nee LEE 14 2 2A OMY V CIE e 14 22221 6 OVE pressed ge e EE and lge e CC su cncanianatanadatcnandadandaanadandsandnandiuadnandnansnananaadnaad E a 15 Pg aS ene A a 15 ZO cp le Brd e 16 Da O ana 16 22ed 12 e RE ele E e RE EE 17 Se a e unt eigene e CEET 18 Zaid E POSE e g EH 19 2 2 1 15 Select Material and Manufacturer NENNEN NEEN ENEE EEN 19 222 CUSto mer HEET Miri AE EE 19 22 Order SCING EE 20 E SCAN E ne 20 E ele A PP o E 21 244 Handing Orders iw DentalManagde asientan iio 21 241 Seanming am Ord Gr asirios 21 Zin 2 TIMPOre SCAN RE 22 2 4 3 Imported Scans from Intra Oral Scanners itie
143. restoration Crucially the type of kit selected depends fully on the given scan abutment configuration Specifying an implant kit i e the scan abutment type to look for will guide the system throughout the scanning process If the implant kit type does not correspond to the type of the scan abutment detected during the scanning process this will result in the system failure to process the order further Please see chapter Abutments for more details on implant systems and abutment kits Abutments can be arranged in groups with each group having its common insertion direction This allows to model upper structures on top of customized abutments the resulting customized abutments will be in parallel by default as long as the Top cap is not rotated during the modelling In order to define a group select the desired teeth with the cursor and choose Create Group from the Abutment drop down menu Should a second group of abutments be created it would have an incremental number Select Ungroup or Ungroup all to delete one or all groups You can define and later on design items on top of the abutments 2 2 1 13 Implant Bars and Bridges 1 Select preparations In the teeth overview Order details 2 Click the Abutment button 3 Select all units in bridge in the teeth overview 4 Click the Bridge button and select a bar bridge System Wibal he Not in group Index 12 Additiona
144. rform one of the following actions select Model ca button from the Main toolbar or 0 e right click on the order and select Model or e double click on the order it will automatically bring you to the next step which is modeling in this case 2 When DentalDesigner application opens up follow the instructions to successfully perform order modeling After the modeling process the order receives status Modeled The DentalDesigner applications can remain open for the coming order after completing a specific order which improves the speed of the whole process Please see DentalDesigner chapter for more details on how to model an order 2 4 5 Manufacturing Orders 2 4 5 1 Manual Handling of Manufacturing Files If manufacturing is allowed at the site then manufacturing files can be accessed in Windows Explorer started from DentalManager using the combination of keys Shift F4 These files are created automatically if local manufacturing is chosen but if it is remote manufacturing then the F7 key needs to be pressed By clicking the F7 key you Generate CAM output which can be also accessed in the Advanced tab when you right click on the order After the CAM output o aues Manufacturing folder of the order including the STL pa e ban ManufacturingDir 20090908 147 Tech oi Fl earch E as e 69 ear output files rite Link Name MA Daie modified Type Sune E Document Co 20081909_1437_Tech_01 D 8 BERTONE 2
145. rgon 2 4 8 15 j de p 3Shape Dental System Control Panel version 2 5 4 8 Lei 3Shape 3D Viewer at Sa version 1 2 5 0 Ps 3Shape 3MLEditor version 2 6 2 0 P sd 3S5hape l ScanltRestoration verdon 2 5 4 8 LA 35hape 1 Scanitimpression version 2 5 4 6 Ka 35hape ScanTtLibrary versi n 2 5 4 8 The column to the left displays the applications that this package contains In the right part of the window you are given the list of installations and options from which you have to choose one Stand alone installation is ideal if you want to run all 3Shape Dental System applications from this computer i e the scanner PC The software and order data are stored locally on this computer Server installation is ideal if you want to run the 3Shape Dental System applications from different computers within the site The software and order data are stored locally on your Server computer but the drives are mapped as network drives so they can be seen by the network client installations Network Client is ideal if you have already have a Server installation on a computer within the site It will simply makes desktop links to the software on the Server computer The software and order data are stored on the shared network drives of Server computer that can be seen by the network client installations Restore Backup select this option to go to your previous local backup of the system Exit installation select th
146. ring Network The Manufacturers are also able to import new materials used in a received order as part of accepting the order for production After configuring settings in Dental System Control and filling in the Order from scan and or model your order and send it to the manufacturer To do so e right click on the order and select Send to Manufacturer or e click on in the Main toolbar You will be prompted by the window similar to the one below Click Send to upload the order and then close the window Note More than one order can be selected and sent simultaneously A E Send ho Manufacturer e LS ribera Me forn reckt e ready bo a el do e pace mar eran Chick Gerd lo at e pisadas Chick e tac button lo geg Mumi ler ec Eure Pea Gon late Ltr ste IK Mateus 213 2009 s Conn 30 Crean a 2 Fotz trat Sree ETS DIE wes eng Ext 20000541 194 Tech Sb a WO A ka Tee p Drion dree fed yo me aja 17 emi emi Aaii Hills rn O Brad Fora Hills Copey 20 Bradford M ng Alini S a PRP naa o i i e Please see Inbox Add On Module chapter for more details 2 4 5 3 Closing Orders Sg L By status Once orders have been produced by the manufacturer and shipped back to the a end user the orders are ready to be closed Closed orders are still accessible vow gl Created through the Closed filter i BRER B Scanned eee e Modelled i all Hint It is recommended to close orders since too many A sent lt order
147. ry Cereal Zeciem Control Panel hasten Zettsen ZES hal Sere CO tack Mergani Home E d D sen y d rt ri rt rt A A D d E q The Material Settings category displays 6 subcategories which are described in the sections further Basic Elements Anatomy Elements Frame Elements Primary Telescopes Abutments Bridge Elements 6 3 1 Basic Elements This category contains the settings for the basic elements of the applications such as materials libraries etc Materials Here you can specify and edit materials which are to be used in the construction elements The Materials interface is illustrated in the image A Ee E Gg rr par ae a bag DH Dental System Control Panel Material lal Save E Back Navigation Home Material Settings Edit Material ID Configuration_11_Materiall Change ID External ID for interfacing with third party software Mame h Zirkon Shader material Default scan module Default design module oF Add Lise colors Aja Copy A Delete R Move up Minimum manufacturing values validation ay Move down Write protect validation settings Recycle bin Validation enforcement policy User can choose to ignore violations ei Mo items Minimum wall thickness 0 43 fp Restore all items SS ei Distance from margin line mm gl Empty the Recycle Bin Minimum connector area ror Details Minimum connector strength Wu Total 3 items You can edit the mat
148. ry Dead Diirea ar y d 1 Main toolbar 2 Main window The Main window contains five categories System Settings Material Settings Site Settings DentalManager Open dongle in 3Shape Dongle Service Choose the one you need by left clicking on it it will open up and display the necessary settings The categories are described in details in the following chapters The Main toolbar contains Save and Back buttons and Navigation link that shows the current level and allows easy entry to the higher level with a click H save E Back Navigation Home Dental Manager The Tasks tab displays a summary of options and categories located in the Main window The Details tab shows the installed applications if there is a red cross instead of a green check mark next to it the application was not correctly recognized 6 1 System Settings A When the System Settings configuration screen is accessed you can set up the main information sources of the application The image below illustrates the main window of this category more settings are available when scrolled down kH Jare OH Back Navigation Home Tasks System Settings ap Set DentalDesigrer path eh Set ScanttReshoration path DentalDesigner a Set SCartl fe ze path gt Set Scanttlnpression path DentaDesigner is currently defined as eg Set Facelt path C Program Fies 3Shape DentalDbesigner e Set DentelManager path Crentalbesigner 2008 legacy ver
149. s Onlays Veneers Overlay tab Name Wax gt Gold Crown tangent Transition distance specifies the transition away Wall thickness Sal mm from the preparation line where the minimum ae My thickness is not fully applied If a point on the inlay Preparation line offset e MA is further than the transition distance from the preparation line it needs to satisfy the minimum thickness Offset angle Extension offset mm If it is closer however the minimum thickness is smaller decreasing to O at the preparation line Edge design facial offset men allowing sharp edges Edge design lingual offset Uu Edge design interprox1 offset 20 S IO Edge design interprox2 offset mm Crown degrading Perform cutting to antagonist Cut distance to antagonist Snap distance and Locality radius are used for the antagonist contact The special points that are used for adjusting to the antagonist are not used directly but any point within the Locality radius from these points can be moved to the antagonist The Snap distance defines how far the point can be moved from antagonist if closer than the snap distance it is adjusted to the antagonist 6 3 3 Frame Elements The Frame elements category contains the settings for defining the framework of a restoration Frame elements SES b Copings Frame Pontics H VW axuips There are three subcategories presented here Copings Frame Pontics and Waxup Copings Edit Coping ID Configuration_1 NEE
150. s done by positioning the blue control point next to where the margin line is If it s a pontic there is no margin line there and you need to place the control point in the front central part of the stump as shown on the following image CT DI You can place and move the points with the mouse and click Clear to delete them Click OK to move to the Insertion direction stage or Telescope direction if you re working on a telescope ee 3shape Lei Ce A INSERTION DIRECTION The Insertion direction stage comes next after Annotations or Telescope Direction and serves two purposes 1 Defining the insertion direction i e the direction according to which the restoration is inserted on top of the die 2 Setting the margin line The Insertion Direction stage provides only a rough estimate of the margin line the actual margin line is defined at the Margin line stage You are able to modify the margin line using keyboard mouse or the Edit points tool displayed in the Tool Forms Using keyboard 1 Select the Keyboard button 2 Press the RIGHT and LEFT keys on the keyboard to change between points 3 Press the UP and DOWN keys on the keyboard to move the points up and down press Ctri Shift to make the points move faster Yea E Order Frame bridge 2 4 Clinic Sunny Clinic Using mouse 1 Select the Mouse button 2 Place a point on the die by pressing the left mouse button The
151. s in the Modelled filter will lead to slower DentalManager L performance when opening this filter Also you can specify the rees Closed number of orders to be displayed by default in Dental System y Control Panel DSCP gt DentalManager gt General Sen CO Other filters One Checked out ae All open 2 5 Additional Options 2 5 1 Finding Orders There are several ways of finding existing orders in DentalManager e Using the Search field located in the upper right corner of the main window Click on the little black arrow next to the magnifying glass to select search criteria e Using the filters that are located in the left part of the main window the last search is always stored in the Search filter e By selecting the specific columns e g order number creation date etc i de s B MAA de ji a e o rel a a z z KL A ME a Wi lB tee ha bien Ss da ch e a ham DR ee ir Cheater cate ang Zeie ey e ee Cap E Cr e p i e iy SE KS A a Fi Crapper debe T i hos Ica Celery dmir lt Daf mena Lg rech DL fe fen si 7 Z vm VAN Beate Eege ee a seas I il kg Wig mre 1 Zeg D ATPT EI wwen Ua mee Cer H band Er iii 8 T Bes UN WER Pach EI pl AUTOS AA SEL SEN e LR SEI ES bech PI sel PID rn UA fares Ce ron 5 hp Tari ds ET ZKEaAn EI ATA mm A eg MIA Surry Chee Fa mea brick 3 4 ul i F e Clare lr ri
152. s offers the option to attach a model component on the side of the telescope Click on the telescope surface to set the position of the attachment A point indicating the position will appear This point can be dragged along the surface or removed again when pressing the Clear button The green cross at the point indicates the angle and depth of the attachment These parameters can be adjusted using the following settings Setti x naa e The Name drop down box offers a list of components that you can choose Name Cube r from Min dist to 00 3 men e The Adjust angle slide bar changes the insertion direction angle of the interface attachment SEN o e Inthe Min dist to interface edit box the minimum distance between the djust angle telescope interface and the frontal surface of the attached component can be Point is valid SS adjusted The green cross is moved either inwards or outwards accordingly e To attach the component press Apply The component can be repositioned by moving the attachment point remember to also readjust the angle or Apoly remove by pressing Clear Click OK to complete the stage If you want to modify your telescope go to Sculpt stage to use the Sculpt toolkit please see Sculpt in Single Coping section for more details Go to the Save step to save your telescope Sculpt This stage is identical to Scu pt described in Single Coping chapter 5 2 2 12 Customized Abutments Annotations This stage
153. section Order Details This section contains This illustration of upper and lower teeth rows helps you create your order Click on the TESEV Overview Nap tooth teeth you need and select a desired restoration When a cursor is moved over a tooth this field displays the numbering index The type of index can be selected in Dental System Control Panel System Settings gt Miscellaneous gt Tooth Index System The default index system is FDI Notation Teeth numbering information After the type of restoration has been selected you can see the preview of the tooth Teeth Preview by moving the cursor over it see the image above These buttons contain information about the nature of restoration to be performed as Restoration buttons well as materials manufactures etc To define an order select the desired tooth teeth from the Overview map by clicking on it with the cursor The selection will be circled in red After that click on one of the restoration buttons to choose the desired operation The Dental System software allows working in layers You can easily start with a coping and add a crown on top for example Once the relevant restoration is selected the tooth will change its color or shape according to the chosen restoration button Next to every restoration button you will find menus with different options material manufacturer color etc It is possible to select more than one tooth at a time Click on several te
154. sion i curently defined 4 C Program Ales135hapelDentalDesigner2008 11 ALO fave miterra minute fs bk B PRE BE L Use auto save during modeling Use AddRamove Intelligent component in DentaDbesigner M Use Parametric Abutment Generation tool ScanltRestoration ES SC anit eztor ation i currently defined zz C Program Fles SShape ScanitRestoration Browse Scanitlibrary ZS Sc spilt br ar is currently defined as C Program Flles 3Shape ScanitLibrary Before Dental System applications can be run it is mandatory to verify locations for DentalDesigner ScanItRestoration DentalManager 3Shape Dongle Service and the location of the orders and output directories Many of these settings will have meaningful values from the installation upgrade of the Dental System If 3Shape Dental System is installed as a shared system at the site then it is only possible to choose shared network folders for the different applications and output directories DentalDesigner To allow Dental System Control Panel to communicate with DentalDesigner the location of DentalDesigner must be known by Dental System Control Panel ke D i 1 De ntalDesigner DentalDesigner is currently defined as C Program Files 3ShapelDentalDesigner The location is usually correctly specified but if changes are required click on the Browse button to open up a file tree and locate the application in its installation C Program Files 3Shape DentalDesigner2008 1
155. sion or Object type Model Antagonist l Se l The D700 scanner delivers high quality impression scans Direct eeh SEWN SEIMEI PSI NEF scanning of silicone and alginate impressions represents a unique Neighborhood scan opportunity for work process optimization and cost saving to labs and Double preparation E large scale dentists Pre preparation scan The turnaround time is reduced by instantly going from physical impression to a high accuracy digital model 3 1 Physical impression 2 Digitalscan 3 Virtual model creation amp CAD 4 Physical model Antagonist you can scan an antagonist to get a more precise result Choose between Antagonist bite and Antagonist model or select None if you do not want to scan the antagonist Face scan the new 3Shape Dental Face Scanning solution allows the dentist or lab to visualize and interactively update the planned dental treatment with the patient The pre treatment visualization is achieved by combining 3D scans of the patient s face and teeth and importing these into 3Shape s Dental System Double Preparation allows scanning of additional information e g in order to design and scan the desired framework in wax Neighborhood Scan select this check box to get the scan of the neighbouring teeth for the additional model information e g proximal contact points Pre preparation Scan the pre preparation model and diagnostic wax up contain very valuable informa
156. some types of restorations see the check boxes in the image above Colors The color of restoration material can be defined here You can add copy delete colors and modify them at any time 51 A AZ Change ID i i KE Al Wm 6 3 2 Anatomy Elements The Anatomy elements category contains the settings for defining the anatomical items which form the outer appearance of a tooth Four subcategories are presented here Crowns Crown Pontics Inlays and Onlays Veneers Their settings are similar each subcategory consists of three tabs Edit Crown Crown Pontic Inlays or Onlays Veneers Cement space and Overlay the Overlay tab is different for Inlays Onlays Veneers see below The example below illustrates Crowns subcategory and its settings Edit Crown The crowns crown pontics inlays and onlays veneers can be edited here added copied deleted etc please see Change ID chapter Basic Elements for more details Wax gt Gold Crown tangent wae Red Wax ki Standard Specify Color and Material they will be reflected in the Order Form Default library name is the name of the crown crown pontic inlays onlays veneers library as it will be displayed in the Order Form Marne Wax gt Gold Crown tangent era ne y Remove undercuts when checked the undercuts are Fa removed when creating the cement space 0 040 5 mm The Cement Space tab contains data for specifying the inner surface of an it
157. sportation occcccccccnnnnnnnnnnrrrr rr rr 6 Bro Ao PP o ne AA 3 Mista Pe OE O TO 3 Spaceball is a motion controller that works in conjunction with the mouse and enables you to navigate through 3D images quickly The device contains the navigation ball and programmable buttons Utilization of 3D software implies to the use of different keyboards keys interface buttons and mouse buttons to switch between panning rotating and view zooming This awkward way of working is eliminated by employing the Spaceball as the single controller that can be now used to complete many functions without having to toggle between different navigation modes A 159 DD User Interface 91 IS Le et EE 10 Order DetallS a KEN EKKKESE ORK NENNEN NNN NENNEN Se 10 Dental Mana Sr evento tenida 7 Dental System Control Panel 132 Dental System Installer NENNEN 170 Dentaliesioner ee NEE NEEN 91 Re Ee ie EE 157 Det Eeer EE 118 Mica A oo O 124 Distance Meaeuremente nn 130 Double Preparation esse iaa 57 E e E 159 F t ZO EE 125 EEE e 25 Digo TEE 25 A e E Eo EE A 94 Frame ES MENS nr ce 144 TEE ee ENEE 13 38 111 Full Anatomical Bridge NENNEN 38 110 Full Anatomical Crown s assesessersenrerrerrerrerrenne 12 38 109 Full Anatomy ee LCE 13 G e tere 157 Generate CAM Output ccc eee REENEN ENEE 26 H Handling OFrGersS scores tontos robin 30 I Implant Bars 18 48 122 LMDOM SCAM E 21 22 IMPreSSiONS cri coria 66 SCANNING AAAMOOO e e o
158. sures distance to antagonist scan 5 1 1 2 Visualization Toolbar DentalDesigner comes with a set of tools and functions aimed to help you find the most advantageous visualization in different situations The table below describes buttons of the Visualization Toolbar and their functionality View the view buttons allow you to switch between a number of predefined viewpoints Placement overview enables you to control the alignment of crowns and pontics in a customized crown bridge Point dragging changes the degree of spline point dragging for all features 2D Cross section provides the 2D cross section for a better model inspection 2D cross sections can be specified either by placing three points on the 3D model or by dragging a section line by holding down the left mouse button and then moving the mouse over the model please see section 2D Cross Section Window for more information Model Visibility enables visualization of the necessary 3D model elements see section Model Visibility for more information P Validation evaluates the restoration according to the standard minimal values pre set in Dental System Control Panel or manually defined and marks the areas that need correction Bounding box outlines the borders of an active element of the restoration or the whole restoration 4 Origin assists orientation of the restoration model according to the standard three geometrical S axes x y and z which are inde
159. swing axis of the scanner should be secured each time the scanner is transported using the swing protection foam If the original packing materials have been lost or damaged a new packaging set can be ordered from 3Shape 1 4 2 Transportation of D250 Please follow the steps below to perform a successful transportation 1 Press the Transport Position button in the ScanServer program to place the linear axis in the correct position 2 Close down the ScanServer software and mount the transportation security plate EE 1 Two bolts for transport security plate 2 Transport security plate 2 Order Creation amp Management DentalManager 3Shape DentalManager is a part of 3Shape Dental System comprised of a number of separate applications DentalManager is the main application handling the orders through the production processes and controlling the ScanItRestoration and DentalDesigner applications 3Shape DentalManager is an easy to use data management application which systematically organizes all production data and acts as a platform for active order data management through the production stages Order Creation Scanning Designing Sending for Manufacturing and Manufacturing DentalManager ensures that new order creation case scanning and restoration design can take place in parallel to one another see the image below 3Shape DentalManager comes with a standard Order handling part which can be extended with an Inbox mod
160. t Click Close to end the modelling of your restoration in DentalDesigner DentalDesigner remains open until you manually close it 5 3 Optional Modeling Steps 5 3 1 Remove Artifacts At this stage the scan artifacts can be removed e g bubbles dents bumps etc Notice when you leave the Directions step to go to the Interfaces step the program automatically brings you to Margin line and not to Remove artefacts even thought it comes first This is because you generally do not need to remove artifacts To save time you start working immediately on the margin line If you do need to remove artifacts click on this stage and use either Paint S or Spline i gt tool to do so To use Paint select the tool click on a desired place of the model and drag the mouse to color the specific area see image next page Use the Paint Radius slide bar to change the radius of the painted area 1 Using Paint tool To use Spline select the tool and form a circle from dots on a desired area of the model see image below fede Pre Behm ZA Galia e soon 2 Using Spline tool di Note When you form the circle clockwise the changes occur outside the spline and when you form it counterclockwise they occur inside the spline Click Apply to see the changes If you put the spline by mistake in one direction instead of another click Swap dir to change direction To view and correct bad triangulation on the scan click the Detect bad
161. t Name Point distance Smoothing Maintain angle used for automatic detection of the margin line Low values will place the automatically detected margin line on surface extrema i e sharp edges while high values will place the automatically detected margin line where the Angle criterium is fulfilled Smoothing a postprocessing step in the automatic detection scheme high values apply significant smoothing to the automatically detected margin line making it appear very aesthetically pleasing but less accurate and vice versa for low values Anatomy and Pontic Libraries You can specify here a collection of pontics and crowns to be used as construction elements Libraries Edit Anatomy and Pontic libraries Standard c15 C20 C25 Prismatik vil 0 Premium Li ID Configuration_11_CrownLibrary1 Change ID Name Standard Library path ae e Library path oC Program Files 3Shape Dental Motor Control Panel library 3ShapelCrowns Standard Premium L18 Premium Posteriors Premium Creoid Premium Rectangular Premium Square Di papp pap Tier 1 Library is available for the following types Crowns and Crown Pontics Frame Pontics Inlays Onlays and Veneers Library path is a link to the folder containing a set of crown and pontic models in stl or dcm formats Click on the path name see the image above to specify a new path You can also Add Copy Delete libraries and make them available unavailable for
162. ta ira CO Di F E r D la ES a A Tee E ca H T ie io Ae inta F Lee ffe eo lor De polo ao ara pra pea pci ashape gt The virtual model design is now complete and the model has been saved The final models from the virtual model design are automatically saved in the order folder in the subfolder Virtual Trimming If you would like to start the modeling process in DentalDesigner click the Design button 4 4 5 Antagonist Posterior Anterior Triple Trays Scan settings Before scanning an impression with the antagonist define your order in Bree re the Order form Select Impression as an object type and Posterior or Anterior triple tray for the antagonist Click OK to save your order heee which will appear in the DentalManager order list with the status sesen Wes Created You can also start ScanItImpression directly from the Order form by clicking the Scan button Otherwise select the created order from the DentalManager order list and start ScanItImpression by clicking Next or Scan When the program opens insert the impression model into the scanner and Insert Impression with click Next button to initiate the scanning process preparation side up A fast overview scan is performed and appears on the E screen shortly The application asks you to mark the E teeth included in your order Select each preparation F individually and click Continue after each one D E E cups m hy F
163. tance to spline 2 Gap radius The Connectors tab contains settings for defining a connector see the image below Connector Edit Connector Silhouette Circular Grom ID Configuration 11 Link TypeConnmectors Change ID Circular 9mm Elliptical 6mm Name Silhouette Elliptical Sram SE None Connector snape type Silhouette Facial distance 02 mm Falatal lingual dist 0 1 mm Occlusal distance men dh Add Counter occlusal dist men p Copy i Center stretch 0 70 A Delete H move up Center scale Mica Center shift up o oo Center shitt back Recycle bin AE Mo items Number of points E Restore all items SE E Area 9 00 men ola ea Empty the Recycle Bin Settings can differ depending on the type of connector Silhouette Circular or Elliptical e Settings common for all types of connectors are Connector shape type defines the type of connector Si houette Circular Elliptical or None Center stretch defines the stretching of connector Center scale defines the scaling of connector Center shift up defines the shifting of a central part of connector occlusal Center shift back defines the shifting of a central part of connector facial Number of points defines the number of points in the connector control splines The default number is 6 points Area defines the approximate area of the sliced connector located at the connector control splines e Settings specific for the Silhouette conne
164. tation occurs in a given plane marked yellow while Free rotation results in a fully free rotation following the mouse movement The top cap is rotated by clicking and dragging one of the central points marked purple The adjacent arrows illustrate the direction of the orientation Morph mode when this check box is selected the silhouette of the cap is drawn and the mouse position is visualized by a grey circle which marks the radius of the morphing effect the radius of a circle can be changes by scrolling the mouse wheel The red direction arrow specifies the centre of the area being morphed and the direction of the morphing in relation to the user The top cap is morphed by dragging the silhouette which turns green when active or by clicking on a top cap and moving in and out Remove undercuts removes undercuts when the check box is selected Fit to Emergence Profile automatically fits the top cap Deformation the top cap can be modified with the help of a bounding box Click and move the green control points which turn yellow when active or click on the blue string to move the three control points simultaneously the string turns red when active Select the Reset control points check box to set the points in the initial position Edit top cap boundary define the bottom boundary of a top cap by placing a spline on its surface The red spline around the abutment cap specifies the maximal bottom boundary of the top cap C
165. the desired option lore Order lore CAM Sbuft AEA Generate CAM Output Fl 2 6 Inbox Add On Module The DentalManager Inbox add on module allows laboratories sites to send orders to the Inbox and the production facilities to collect orders from it Using the Inbox the Manufacturers are able to send out the parts of their material file that specifies production parameters e g drill radius and minimum material thicknesses this functionality is called the Manufacturing Network The Manufacturers are also able to import new materials used in a received order as part of accepting the order for production Options II The availability of the Inbox module can be viewed from the License Information page Leene TA opened via the application Help menu Send Bug Report EE The License Information page see image below displays information on the dongle It is possible to check for dongle updates or show the server log file by clicking the About Dental Manager corresponding buttons at the bottom of the page Open Log file tk heplfuier pesiisiy i Der AS Ft LiF Serre H i di Shape Dongle Zeracr fey D se spe D Took ri Betteng Va KEE mr Cured aff Te default intranet In Aer ten use ure Eftir terre betta Chek for pphini E 35hape Dongle Service cesos 0 00 1 Dongle number 344547437 Dentaldesigner Emer ZU LUUT L Points m dangle 1 Ports mi uae O Points available 1 Chant a da Dental Deacapner
166. the process To move to the next Design step click Next COPINGS This section describes the modelling processes for both standard and anatomical copings 1 Standard coping When you proceed to the Frame design step DentalDesigner automatically places copings and pontics but you can always modify them as desired Click on the Coping button in the Process toolbar to specify the settings for your coping see image below Select the element from the Coping drop down menu to choose the settings for creating the outside of the coping the settings are pre defined in Dental System Control Panel Advanced Settings Wall thickness 1 is the normal amount of offset i e the thickness of the coping Wall height 2 is the distance from the margin line to the borderline marking the beginning of the area where the wall thickness is applied Margin line offset 3 the Offset angle 1 4 and the Extension offset 5 are all used for defining the overlay shape near the margin line com 299 Arcon Coping chamfer E Wall hidness 0 50 E mm Wall height 1505 men Margin line offset 0 08 E mm Offsetangle 1 Song Extension offset 0 10 men Lingual band Apply Ed Start angle in End angle 2a Sr Offset 1 00 SE mm 0 Order Coping 2 Lingual band The Lingual band settings define the lingual band of the coping see image above When Apply is checked the lingual band is created Start ang
167. tion for modeling of full anatomical crowns and general restorative work Hence the pre preparation model and diagnostic wax up can now be scanned and aligned to the normal preparation scan and visualized during the design phase 2 3 Modifying Orders Orders that have been created but not scanned yet can be modified as described below However if their status is Scanned or one of the further statuses the order can be opened in Read Only mode except for the Manufacturer which might be changed later on To modify an order e Click on the ES button in the Main toolbar or e Left click on the order and select Modify from the menu Modifying the existing orders can be very useful for example when you want to select another remote manufacturer this can be also done after the design is completed or scanning an impression instead of a model etc 2 4 Handling Orders in DentalManager 2 4 1 Scanning an Order Follow the steps below to scan an order with status Created 1 Select an order you need to scan and perform one of the following actions select Scan O button from the Main toolbar or right click on the order and select Scan or double click on the order it will automatically bring you to the next step scanning 2 When ScanltRestoration or ScanItImpression application opens up follow the instructions to successfully perform scanning After scanning the order receives status Scanned The scanning applications can no
168. tion or remove gum tissue The next virtual modeling operation is to ditch the dies A margin line must be defined for each preparation Click a point on the top of the displayed tooth the software will then automatically find a margin which can be edited as usual Alternatively the margin can be drawn by dragging the mouse Click Next to continue Note 3Shape highly recommends that the dentist prepares using an exposed margin 7 1 l SS Virtual Model Design Shea Safa Hih G i gt Sagaga Gingive travel 3 Enero aon 253 se Er Di Ter z Es Ed see 3shape lik The Removal radius is the radius of the virtual burr used to remove gingival tissue from the surrounding model around the margin line Set the required insertion direction for the tooth with the virtual joystick as shown on the image in the previous chapter Virtual Model Design You can also rotate the die with the cursor and press the Set pin direction button to redefine the current point of view as the insertion direction Click Next to continue Adjust the position of the platform of the articulator interface The position is changed by holding the mouse down over the blue articulator interface and dragging The Articulator drop down menu allows you to select different articulator interfaces Simple Quadrant Simple Full Arch and Base Click the Next button to continue ER el d E Eis a ip 25 Virtual Model Design ra Shep d e d r
169. to scale the model to its real size Edit crown scan Hvze Ier qe baling ce aire Se i Spare Waka af a Box indicating the original size Cut bottom of the model to form a boundary by placing point for the bottom boundary with the cursor and click the Apply button Pit pots on Ube on Joen a balbas boundary Cid on first oore tedireth 3shape gt Remove artifacts if needed using Paint Spline selection or Plane Cut tools Eet ete ol L o Jee JL sm 3shape Ke HE ER EI Add or Remove material if required at the last editing stage geg Be Edit crown scan Sut 5007904 Add lower boundary morph points In order to use the automatic initializing of the crown design it is necessary to add a lower boundary to the scan and a number of morph points The method for adding the lower boundary is similar to the bottom boundary described above When the boundary has been added you are guided to add three types of morph points When the required points have been added they are marked with ticks as shown on the image below Optionally you can also create custom Point Groups by clicking New Having finished with the morphing points click Next to complete scanning and saving operations and morph points Ki MES a e S Oe e KX dy e e info a 3shape 7 3 Library Explorer You can explore the library by selecting File gt
170. ts of your manual trans box rotations click Restore and the program will cancel the changes Click OK when finished ke D Ch Gen Dee KT E E Align single tray D impressions ES al KS AD E ol Kb a C A inte Sj v F d a tear i x WF freeen E WW Green ES hawe Culhisiuna 24 PE ec vos 3shape Sa Scanning complete All models have been Chek eg o proc deed Io virtual adal dngn Lafe SA EEE 3shape gt When clicked the Corrections optional button expands to A preparation side ge Corrections optional E rss F Remove Artefacts Click Next to go to the Virtual Model Design step and do trimming to the model and antagonist 4 4 4 Virtual Model Design Once trimming of the model and antagonist has been performed click OK to continue Note Make sure you include the adjacent teeth to the selection region BB Virtual Model Design m Siet Let A Trim mod l Piyari keet T adac nti di el ap pr piridiona m IL n D El ml E IS H T DI ch d inte ap ef Bia s a Ai k e of n E La et SS Virtual Model Design Sea 2 of i Tom amapan d Spe 50004 la a k k TOP Chet porda ane be ore E ar ag ride hee ot s prt ie ashape The Add Remove material stage is an optional stage that can be used to modify the impression e g to correct flaws in the prepara
171. ual modeling operation is to ditch the dies A margin line must be defined for each preparation please see the previous chapter Virtual Model Design Click a point on the top of the displayed tooth the software will then automatically find a margin which can be edited as usual Alternatively the margin can be drawn by dragging the mouse Click Next to continue Note 3Shape highly recommends that the dentist prepares using an exposed margin The Removal radius is the radius of the virtual burr used to remove gingival tissue from the surrounding model around the margin line Set the required insertion direction for the tooth with the virtual joystick as shown on the image below You can also rotate the die with the cursor and press the Set pin direction button to redefine the current point of view as the insertion direction Click Next to continue Virtual Model Design Shep 3 of A Ditch dies 500050 vlt Aaf T nen E 4 P CN LEE LA SERIES 3shape OOo O Adjust the position of the platform with the articulator interface The position is changed by holding the mouse down over the blue articulator interface and dragging The Articulator drop down menu allows you to select different articulator interfaces Simple Quadrant Simple Full Arch and Base Click the Next button to continue Virtual Model Design eo a Aid bite ab aa A ebe AG ff p Ier e dt A ar S d E Fe
172. uette k Select preparations in the teeth overview Click the Anatomy button Select pontic in the teeth overview Click the Anatomy button and select crown pontic Select all units in bridge in the teeth overview Click the Bridge button Select preparations in the teeth overview Click the Frame button and select an anatomical coping Select pontic in the teeth overview Click the Frame button and select an anatomical pontic Select all units in bridge in the teeth overview Click the Bridge button 2 2 1 6 Inlay Inlay Bridge y 1 Select preparations in Order details the teeth overview 2 Click the Anatomy button and select an inlay Wax 3 Select all units in bridge in the teeth overview 4 Click the Bridge button kd Index 14 Additional 2 2 1 7 Onlay Veneers E 1 Select preparation in Order details the teeth overview 2 Click the Anatomy button and select an onlay veneer Wax Max Veneer Abutment Index 9 Additional 2 2 1 8 Over pressed Crowns and Bridges Order details SPIES Type Silhouette Index 14 Additional 1 Select preparations in the teeth overview 2 Click the Frame button 3 Click the Anatomy button 4 Select pontic in the teeth overview 5 Click the Fram
173. uity for undercuts removal Click Apply to view changes click OK to go to Sculpt Sculpt Sculpt toolkit The Sculpt toolkit is a set of useful tools which appears as the last stage of the nu D modelling steps to enable you to transform and shape your restoration The tool is the as he 3 Se same for all kinds of restoration items The Global transformations be button allows you to move scale and rotate the model marked red see image to the right The adjacent arrows illustrate the The model is rotated by clicking and dragging one of the central points direction of the orientation Drag the blue points to change the shape of a top part of a model by moving it sidewise Drag the green points to change the shape of a whole model by moving it sidewise back and forth or up and down Points become yellow when activated The view of all points changes depending on the view direction top front etc Sculpt toolkit Point morph Free morph silhouette moarph 3 Free morph silhouette morph 2 Rotation Cut to antagonist skew scaling 2 scaling Rotation 2 Undo all 15 Dip Click the Undo operation ol button to cancel the latest operation To cancel the previous changes to the model click on the little black arrow next to the button and select the operations you want to cancel see image to the left Note To cancel any operation the operations following it has to be cancelled as well Ca
174. ule Order Creation Scanning External Manufacturing CAD Modeling In house Manufacturing CAD Modeling Significant productivity enhancement by order creation scanning and design taking place in parallel either with a single or multiple PCs 2 1 User Interface Start the application by clicking the DentalManager desktop shortcut You will be prompted by a window El similar to the image below 1 Main menu Less a former 3 a IS 2 Main toolbar CA GER Tang rg Lee eg 3 gt Open log Ale RW zoanen Le tek Er Kn Eat vum TEEN k n L i Cane aa dd ii 3 Column headers fe he E ege Cote paa iEF a D wf ten bi Ted Ei Een Preman ee a men Kaap L Le geg See bh meet an 200 hd jas Cara Zone 4 Orders rte Ka SP k i ame ur r Ee Pam UA Ze EI d ng bis IER WETA ABC Le Per KE i et BEER MA i l 5 Order status icons A Ae teg some KR 2 000 ge tcc umn UREA kee Dm Creer 8 mm Faren i Poma TO mo e zen e d 6 Order filter oer Gs zm ge CR uE Erari en Um emt ec E um e 7i ee irra Ma Reger E Co i Ade Pia L e j 5 j pin Ra z ERTE HLE i DW 4 Wu zeen 2012 Ju ts m Kam ran fe ai H o 7 Information on selected e Inte LEE MA TAE di Tham its hes Ce SE m Deng Item TOT tent owes sr A ia La Ze EEEE EE ur F z d Cisne TO EEN ef wem Ae KR hei d Fe Sne gemeng Tule 8 3D preview D oew mer z Fegd ai EA Prier VK A IA Farma Chew dra feds Ago fra Cragg
175. ule is designed to scan various restorations while saving them in files at the predefined location setup in Dental System Control Panel The scanning is very intuitive although some technical knowledge is required to get optimal results from ScanItRestoration Most objects to be scanned will be fixed to a simple interface plate see chapter Unpacking and Installation before being inserted into the scanner The interface plate facilitates connection between the scan object and the scanner The object to be scanned is fixed to the top of the interface plate using clay Once the object is fastened into place it can be inserted into the scanner 3 1 User Interface To start working with ScanItRestoration you have to first define your order in the Order form see chapter Creating Orders for more details It now appears in the DentalManager list of orders with the status Created If you want to start the scanning process immediately click on the Scan button this will bring you directly to ScanItRestoration ra rq d d 4 Cigar te Tech O l Cerler ii 20001002 1522 Tech DU eat irm Micii D ee emm pane banal Anaje Maw a See ah A Deen Mee Der atwenpe JU sl rer Sean em E L sm JL e ret Otherwise select the created order from the DentalManager order list and start ScanItRestoration by clicking Next or Scan button in the Main toolbar see image below or right clicking on the order and selecting Next or Scan from the right
176. ult setting in DentalDesigner you can use the right mouse button to pan the model and rotate it in the 3D view The mouse wheel is used to zoom and change pan of the view as described in the table below Wheel down Pan view When pressed move the mouse in the 3D view to pan Wheel scrolled Zoom view Scroll mouse wheel in the 3D view to zoom in and out It is possible to change the 3D view using keyboard shortcuts While holding down one of the keyboard keys and the right mouse button pressed use the cursor to perform the described operations Bn ZE E RN AE Pan view When pressed use the right mouse button to pan the view Rotate view When pressed use the right mouse button to rotate the view Zoom view When pressed use the right mouse button to zoom in and out Appendix C Motion Controllers Support Dental System products support SpaceBall motion controllers Wacom Graphire and Bamboo graphics tablets or other tablets complying with the WinTab standard The indicated controllers use USB interface to connect to a computer and must have appropriate drivers installed to function correctly Please refer to the manufacturer web site for support on the latest drivers available for your controller Graphics Tablet Support A graphics tablet is an electronic device that allows to hand draw images the usual way with the images appearing on a computer screen Some tablets can also be used for primary pointing and navig
177. ur case it is Johnson Milling is selected for the manufacturing process you are using in our case it is Milling RO 4mm Go to Manufacturing process in Dental System Control Panel and check the necessary manufacturer see the image to the left 42 Johnson Milling V Bradford Milling Important e The easiest way of adding manufacturers is if the connection between the lab and the manufacturer has been defined in the Site Connection Administration application in this case you only need to click Import site s from Server in Dental System Control Please refer to your local 3Shape dealer distributor OEM partner if you want to use this functionality to connect to a milling center e If manual adding is done then it is necessary that both the lab and the manufacturer have each other in the site lists in Dental System Control and that the IDs are correct e The lab should preferably synchronize his material settings with those from the milling center this can now be done by importing the materials settings exported by the manufacturer e The lab can choose another manufacturer AFTER scanning modeling the order This is very practical if the originally chosen manufacturer is for some reason not able to do the work Using the Inbox the Manufacturers are able to send out the parts of their material file that specifies production parameters e g drill radius and minimum material thicknesses this functionality is called the Manufactu
178. utment kits using Dental System Control Panel To configure Dental System for customized abutment design follow the steps below 1 Go to Edit implant system in Dental System Control Panel gt Material Settings gt Abutments gt Implant System see the main window in the image above 2 Press the Add button in the Implant Systems group to add a new implant system and type in a unique ID and name e g MyImplant 3 Select the desired system in the Implant Systems group to add parts CAD files to a given implant system Then press Add in one of the desired parts windows to browse the file screw base etc Import all the desired parts before proceeding to the next step 4 Click the Add button in Abutment kit window to create abutment kits from the parts of the active implant system Edit abutment kit wizard will then appear to guide you through the parts selection Follow the wizard instructions and click Finish when done 5 Save changes and close Dental System Control Panel Note In this wizard it is mandatory to select one implant one scan abutment and one base It is optional however to select a screw and an interface Abutment kits without a screw will not be able to generate screw retained abutments at the design step 6 3 6 Bridge Elements Bridge elements Bridge elements category contains two tabs Bars and Connectors j es The Bars tab contains the setting for identifying a bar d construction element The image
179. various stylistic and functional demands of the restoration type Apart from the advanced design setting that are provided in the Tool Forms you can adjust the shape of the bar manually e The green spline on the top of the restoration defined by a number of blue control points marks the upper border of the restoration It is intended to help you conveniently locate the changes applied visually e Rotate the model accordingly to see its horizontal dimensions Move the blue control points to raise or to lower the active section of the bar e Rotate the model accordingly to see its vertical dimensions Move the blue control points to move the active section of the bar closer to or further from the buccal area of the mouth e Check Use straight lines check box to create a geometrically rigid angular shape of the bar Bar setti EE You can modify the shape of the bar in real time by selecting rectangle ellipse or dolder bar shapes this was previously specified in the Order Form Bridge gt Bar bridge E gt Type Distance to spline 0 00 mm Distance to gingiva 0 20 2 mm Define Distance to spline and Distance to gingiva and set the Proximal gap radius Ee considering the radius of the space generated next to the restoration Proximal gapradius 0 50 mm Use straight lines F The bar is divided into sections that can be activated and edited one at a time The active cross section turns yellow You can define the parameters for Distance to spli
180. w remain open for the coming order after completing a specific order which improves the speed of the whole process Please see scanItRestoration chapter for more details on how to scan an order 2 4 2 Import Scan As an alternative to using ScanItRestoration the scan can be imported to the system Right click on the order and select Import Scan When the Open Scan dialog appears select the requested scans and click Open Look ir di ModeUoblD_MJID_ 2013517192953 3 Name Date modif Type P gt Antagonistican DCM Computer me a Metwo rk File name Preparation5 can OCh M Files of type Scan files dem amp stl amp hps M 2 4 3 Imported Scans from Intra Oral Scanners It is possible for 3Shape software users to import and work directly on scans from open intra oral scanners such as ITero To use ITero scan it is necessary to properly export it from the ITero lab software 1 Manually create an order in DentalManager matching the Itero Yiew Control Manufacturer order Exported files are compatible with 35hape Dental System 2 Import the scan by version 2008 1 or later right clicking on the order and selecting Target Folder Ci iTero Export Import Scan 3 Browse the scan file the path can be seen above 4 Continue as normal 2 4 4 Modeling an Order Follow the steps below to model the order with status Scanned 1 Choose an order you need to model and pe
181. with the ScanItImpression add on module Dental System 2009 supports the design of restorations on the basis of adaptive impression scanning ScanItImpression is started automatically when required by an order created in DentalManager With this application you can scan impressions and then design restorations in DentalDesigner In addition ScanItImpression allows you to create trim a virtual model replacing the traditional stone gypsum model that can then be produced by rapid prototyping in parallel to the manufacturing of the actual restoration ScanItImpression can scan the vast majority of typical restoration impressions However if a prepared tooth has a depth to width ratio larger than approx 1 5 the accuracy in the deepest part of the impression may be marginally compromised 4 1 User Interface To start working with ScanItImpression you have to first define your order in the Order form see Creating Orders chapter for more details Open an Order form in DentalManager select Impression as an object type in Scan settings and click OK to save the order The order now appears in the Dental Manager list of orders with the status Created If you want to start the scanning process immediately click on the Scan button this will bring you directly to ScanItImpression 0 Order Form Lab information Dys sm Teh GL Customer information Custom r eren Circ Create dates al oam Sheps debe 41162009 Last name Prat eri Fin name Jam Comments
182. y the first profile spline ready for editing To edit individual emergence profile splines use the mouse to change the position of the points Click on the blue arrows or use the arrow keys on the keyboard to move from one spline to another If you are not satisfied with the design job done click on the Reset current spline or Reset all splines buttons to start over Click Apply to view the changes Click OK to move to the next step At the Emergence profile step the shape of an abutment emergence profile is created This process involves definition of the emergence profile marked with a green line and subsequent editing of the sub gingival emergence profile shape The emergence profile can be designed in two ways 1 By left clicking on the model and placing the blue control points that are automatically connected to form a gingival spline To close the spline left click on the point that was placed first 2 By drawing the spline manually with the left mouse button pressed The estimate spline will then be automatically levelled and marked with the control points for further editing You can edit the resulting gingival spline by moving the control points or pressing the Clear spline button to start placing the spline once again You can also set the Gingival spline offset which defines the distance between the gingival spline on the abutment model and the corresponding spline on the gingiva on the scan Vertical bas
183. ypically corresponds to a given implant manufacturer Each implant system can contain a number of parts an implant a screw an interface a base or a scan abutment blank e An Abutment kit is a collection of parts needed to complete the design of the customized abutment A given kit MUST contain exactly one implant one scan abutment and one base and optionally also a screw and or an interface Abutment kits are created by referencing the models added to a given implant system Multiple abutment kits can reference the same parts and these kits hence allow you to easily combine the various parts belonging to a given implant system 1 EN de TO AA 1 Base 2 Interface 3 Implant 4 Screw When creating implant models it is important to export them in one common coordinate system When handled in this coordinate system the set of models should form a complete assembly i e be positioned relative to each other as when they are assembled into a complete implant I oe ee Hint 3Shape recommends that the origin of the common coordinate system is placed on the upper resting surface of the Y implant and centered on the implants vertical axis Furthermore the y axis of the coordinate system should be aligned with this vertical axis and point upwards i e away from the implant An example of correct placement is shown in the image to the left It is also possible to import implant systems and ab
Download Pdf Manuals
Related Search
Related Contents
Cyclone Baixar - Oregon Scientific 2012 fiche consignes iStarUSA WN368 racks Petra KM55.57 北欧電子株式会社 宛 Anexo B Manual de usuario Sistema de reconocimiento automático Samsung DV56H9100EG Use and Care Manual : Free Download, Borrow, and Streaming : Internet Archive PDA - Quick Start Guide duct type air conditioner operation manual and installation manual Copyright © All rights reserved.