1. degree of protection against electric shock d equipment that can be disinfected e device that is unprotected for being used in the presence of flammable mixture with air or oxygen or nitrogen monoxide f protection degree IP 20 g continuous regime device h portable device Description of the symbols m Clase Il duble x Use By insulation wd Manufacturer k a C 1868 Complying with MDD 42 93 EEC wi Date of manufacture USER MANUAL SaltMed Inhalation Device 9 Disposal of Unit Disposal instructions for items in accordance with the WEEE directive Appliances bearing the symbol shown here may not be disposed of in domestic rubbish You are required to dispose of old electrical and electronic appliances like this separately Please visit www recyclemore co uk or www recylcenow co uk for access to information about the recycling of electrical items The WEEE directive introduced in August 2006 states that all electrical items must be recycled rather than taken to landfill Please arrange to take this appliance to your local Civic Amenity site for recycling once it has reached the end of its life 10 Bibliography 1 Continuous nebulization therapy for asthma with aerosols of B2 agonists Otto G Raabe PhD Timothy M Wong BS Garrett B Wong James W Roxburgh MBA RRT S David Piper and James C Lee BS ANNALS OF ALLERGY ASTHMA amp IMMUNOLOGY VOLUME 80 JUNE 1998 2 Inhaling to mitigate ex
2. the cartridge in its special container for 10 20 hours The silica gel will reduce the humidity 6 USER MANUAL SaltMed Inhalation Device of the SaltMed cartridge After this time shake the cartridge to loosen the microcrystalline salt layer and check its operation using the air pump If the boiling phenomenon does not appear the SaltMed cartridge will need to be replaced 4 SaltMed cartridge replacement SaltMed devices are delivered with an L type cartridge which can be used up to 50 hours To maintain its therapeutic effect a SaltMed L cartridge should be replaced after 40 50 hours of use and within two months of its first use An N type cartridge is also available which can be used up to 100 hours N type cartridges are primarily recommended for hospital intensive use Use original SaltMed cartridges only Please see www saltmed co uk for more details 5 SaltMed Inhalation Device in respiratory therapy The highly concentrated active salt particles optimally sized between 1 and 5 microns are inhaled into the respiratory tract They are dissolved in the mucus layer covering the airway epithelium and attract water from interstitial tissue into the airways As a result inflammation is reduced and hydration of the mucus increases Reduction of local inflammation improves the symptoms related to airway obstruction and inflammation such as nasal obstruction sinus pressure local pain Respiratory secretions fluidisatio
3. USER MANUAL SaltMed Inhalation Device INTRODUCTION The SaltMed inhalation device generates dry salt aerosols with salt particles of 1 5 micron and has been shown to have significant therapeutic benefits in the treatment of respiratory conditions such as Acute Bronchitis Allergic Rhinitis Bronchiolitis Asthma COPD Cough Cystic Fibrosis and several other ENT conditions SaltMed uses an innovative mechanical erosion process based on the forced passing of air through a complex structured dry salt cartridge SaltMed devices are delivered with an L type cartridge which can be used up to 50 hours An N type cartridge is also available which can be used up to 100 hours N type cartridges are primarily recommended for hospital intensive use Please see www saltmed co uk for more details Technology USER MANUAL SaltMed Inhalation Device TABLE OF CONTENTS 1 Important safety precautions page 2 2 Product overview page 4 3 Operation page 5 4 SaltMed cartridge replacement page 7 5 SaltMed Inhalation Device in respiratory therapy page 7 6 Therapeutic recommendations page 8 7 Troubleshooting page 9 8 Technical data page 9 9 Disposal of Unit page 10 10 Bibliography page 11 11 Warranty page 12 1 Important safety precautions When using any electrical appliance basic safety precautions should always be followed including the following Read all instructions carefully before using any appliance Always ensure th
4. aerosols or where in can be splashed with water 2 Product overview The SaltMed device Fig 1 includes the salt cartridge A a mask B air pump C and hose D packed in a fabric bag The air pump is connected to the cartridge with the PVC flexible hose USER MANUAL SaltMed Inhalation Device SaltMed cartridge A is supplied in a special storage container Figure 2 which includes in its lower section silica gel a drying agent to absorb humidity SaltMed cartridges should always be stored in their containers when not in use to maintain the efficacy It is important to keep the SaltMed cartridge dry If the air humidity exceeds 65 due to inadequate cartridge storage blockage of the salt layer will occur and lead to a loss in therapeutic effect SaltMed cartridge in its storage container Photo Cross section Description 1 Container cover 2 Storage container 3 Top cover of cartridge 4 NaCl grain layer E 5 NaCl micro crystals layer 6 Connector PVC tube to air pump 7 Storage container filter 8 Silica gel During use air from the pump passes through the microcrystalline layer in the lower part of the cartridge and will create the visible appearance of a boiling movement The air under pressure erodes the salt micro crystals and generates dry salt particles of 1 5 micron USER MANUAL SaltMed Inhalation Device 3 Operation 1 P
5. at the voltage on the rating label corresponds to the mains voltage in your home Always connect the air pump to a proper electrical outlet 230 V AC Incorrect operation and improper use can damage the appliance and cause injury to the user This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliances by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance Check the power cord and plug regularly for any damage If the cord or the plug is damaged it must be replaced by 2 USER MANUAL SaltMed Inhalation Device the manufacturer or qualified person in order to avoid an electrical hazard Do not use the appliance if it has been dropped or damaged in any way In case of damage take the unit in for examination and or repair by the authorised service agent Never immerse the unit in water or any other liquid for cleaning purposes Remove the plug from the socket by gripping the plug Do not pull on the cord to disconnect the appliance from the mains Always unplug the unit when not in use before cleaning or when adding or removing parts The use of accessory attachments that are not recommended or supplied by the manufacturer may result in injuries fire or electric shock Do not
6. haled bioaerosols David A Edwards Jonathan C Man Peter Brand Jeffrey P Katstra K Sommerer Howard A Stone Edward Nardell and Gerhard Scheuch Communicated by Howard Brenner Massachusetts Institute of Technology Cambridge MA November 4 2004 received for review July 18 2004 USER MANUAL SaltMed Inhalation Device 11 Warranty certificate Device No sceeeeeeeeeeeees Year of manufacture seeeee Cartridge type 66 Year of manufacture 0e08 INVOICE NO eeesee eens Supplied by ssscsseeeee cece sees Full name of purchaser csccsssseeceeeecereseeessceeseseseeees Addressing eralaisnrs aists overs e bins EA E OES Supplier Buyer The pump supplied for the SaltMed Inhalation Device has a warranty of 24 months from date of purchase In case of malfunction return the pump to the manufacturer or the manufacturers authorised representative for repair The repairs shall be free of charge within the warranty period and chargeable after the warranty has expired Warranty applies only if the device has been used in accordance with the manufacturer s recommendations No preventive maintenance operations are necessary Tampering with the device accidental damage and damage due to misuse or negligence will not be covered by warranty and will be chargeable Distributed in the UK by MS DELTA Ltd T 44 0 7977444388 E office saltmed co uk W www saltmed co uk
7. isolated cases e g patients lacking vitamin A E and or with insufficient hydration dryness of the pharynx may occur Administration of Vitamin A E and normalising the hydration will eliminate this effect Contraindications none reported 8 USER MANUAL SaltMed Inhalation Device 7 Troubleshooting Disposables mask tubing cartridge should be checked for damage on receipt and should be returned for replacement within 14 days from the date of receipt If on inspection they are found to be defective they will be replaced free of charge The pump supplied for the SaltMed Inhalation Device has a warranty of 24 months from date of purchase In case of malfunction return the pump to the manufacturer for repair The repairs shall be free of charge within the warranty period and chargeable after the warranty has expired No preventive maintenance operations are necessary 8 Technical data Specifications dimensions package 265x185x75 mm weight 0 6 kg supply voltage 230 V AC 50 Hz air flow 2 l min absorbed power 5 VA fuse T32 mA 250 V AC noise level 60 dBa air pump Resun AC 9601 type storage temperature 5 to 40 C humidity 45 to 65 USER MANUAL SaltMed Inhalation Device Classification According to EN 60601 1 2007 Electro medical devices a device with AC electrical supply b class Il devices upon the type of protection against electric shock c B type applied part upon the
8. lace the air pump on a rigid flat surface 2 Insert the plug into an electrical outlet voltage 230 V AC The pump will create a slight buzzing noise and generate an air flow 3 Connect the PVC hose to the pump using the end marked PUMP 4 Take the SaltMed cartridge from its storage container immediately closing the storage it 5 Attach the other end of the PVC tube to the connector on the lower part of the SaltMed cartridge The boiling phenomenon of the lower micro crystal layer should be observable 6 Attach the mask B to the SaltMed cartridge Place the mask on the face so that the SaltMed cartridge is in a vertical position and breathe normally for the duration of the treatment session 7 At the end of treatment switch off the pump and remove the mask from the face 8 Detach the SaltMed cartridge and place it back into it storage container 9 Wipe the mask with cotton and disinfect it with alcohol ethyl alcohol max 70 It is recommended to periodically wash the mask with warm soapy water and to thoroughly rinse it with clean water 10 Place all of the components back into the fabric bag for protection and keep the bag in a dry place WARNING Moist SaltMed cartridges will produce less salt micro particles and due to this increased humidity the boiling phenomenon of the lower microcrystalline layer may not appear This may reduce the therapeutic effect This situation may be overcome by storing
9. n improves the mucus removal and alleviates the stress of an exhausting dry cough by changing it into a productive cough 7 USER MANUAL SaltMed Inhalation Device Additionally dry salt aerosols increase protection against respiratory infections and provide anti inflammatory immune modulating and desensitisation effects which are very important in allergic respiratory diseases asthma allergic rhinitis Consequences of these effects the SaltMed Inhalation Device assists over time to an elimination of respiratory episodes of infectious cold flu or allergic allergic rhinitis asthma diseases A reduction in relapses and acute exacerbations in chronic patients may also occur 6 Therapeutic recommendations Administration the SaltMed Inhalation Device is recommended for daily use up to three sessions of 30 minutes or more duration depending on the severity of the disorder and the advice of the physician Use of a SaltMed Inhalation Device is a complementary therapy and does not replace conventional treatment Do not interrupt or modify the current treatment protocols recommended by a physician The SaltMed Inhalation Device is intended to be used by an individual person We recommend that you personalise your SaltMed cartridge by filling in your details on the container label Hydrate yourself properly Interactions with other medications SaltMed may be used together with any other medications Side effects In
10. use the appliance for anything other than its intended use Do not carry the appliance by the power cord Do not leave the appliance unattended during use Always unplug the unit when not in use or before cleaning Ensure that the unit is switched off after use The manufacture does not accept responsibility for any damage or injury caused by improper or incorrect use or for repairs carried out by unauthorised personnel In case of technical problems switch off the machine and do not attempt to repair it yourself Return the appliance to the authorised service facility for examination adjustment or repair Always insist on the use of original spare parts Failure to comply with the above mentions precautions and instructions could affect the safe operation of this product Do not use the appliance on a gas or electric cooking top or over or near an open flame Keep the device far from heat and hot surfaces Do not block the air exhaust hole 3 USER MANUAL SaltMed Inhalation Device e The SaltMed cartridge should always be used in the upright vertical position Do not use the air pump on surfaces that could clog the air intake filter e Never use the device while you are sleeping The supply cord cannot be replaced If it is damaged the pump is no longer usable Warning Using a damaged supply cord can result in electric shocks Do not store or use the device in environments with excessive humidity dust oily