Home

BIG FLASH II 1500 User Manual

image

Contents

1. Nunca introduzca objetos a trav s de las rejillas de la unidad No hay elementos de control para el usuario en el interior dir jase a su distribuidor para reparar Conexiones de alimentaci n La unidad dispone de una toma de red adecuada al voltaje que precisa Si es necesaria cualquier otra conexi n el esquema es el siguiente Tierra Cable amarillo verde Neutro Cable azul Fase Cable marr n En Usa y Europa se requiere una clavija de 3 polos con toma de tierra Este dispositivo dispone de un magnetot rmico que protege ante cortocircuitos y sobrecargas Funcionamiento Este efecto ha sido dise ado para funcionar tanto a 120V como a 230V AC y dispone de una toma de red para su conexi n Compruebe la tensi n local y la de la unidad para un perfecto conexionado PA MARK BIG FLASH II 1500 User Manual Manual de Uso Pag 1 pe Antes de comenzar a usar la unidad dir jase a la secci n Instalaci n Sustituci n de l mpara Cuando conecte la unidad accione el magnetot rmico la unidad empezar a parpadear Como el efecto est controlado por el mando de velocidad es necesario ajustarlo a su conveniencia Un jack 1 4 le permite interconexionar los flashes par el manejo con el controlador El funcionamiento continuado de la unidad no debe superar los 15 minutos Instalaci n y Montaje La unidad ha sido dise ada para poder ser colgada Se recomienda por motivos de seguridad que el efecto se monta usando el elemen
2. MA MARK BIG FLASH Il 1500 User Manual e Mounting Bracket gt o LLY At the Rear O mune D Rotary Speed Control e 1 4 x 2 Mono Jacks i for Linking i d ha i e Circuit Breaker Lamp Replacment Cover Dimming knob Fig 1 Please read these instructions carefully befor use Introduction Congratulations on the purchase of your new strob lighting effect you will enjoy your strob light freely To assist with the care and use of the product we have prepared this short guide Troubleshooting e If the unit is not functional check main power supply is on and check fuses e If the unit is functional but lamp does not light lamp may require replacing e If after trying this solution you still have a problem contact your dealer Caution Do not obstruct the air vents Do not touch unit or lamps while hot Never put any objects through the air grill on the top of the unit No user serviceable parts inside please refer to your dealer for service Power Connections The unit is supplied with a power plug appropriate to its voltage and destination Should any other connections be required they must be carried out with the following configuration Earth Green Yellow cable Neutral Blue cable Live Brown cable In the USA amp Europe it is required that all plugs are 3 pin type i e with Earth Ground connection This device have a circuit brea
3. gers Oil from fingers will ruin the lamp Use a clean dry colth for replacement of bulb 5 Gently remove the old lamp from the spring holder 6 Insert the new lamp tube into the spring holder and connect the wires of the lamp into the PCB board according to your memory just now 7 Reassemble Finally before using check that the lamp is housed correctly in the lamp holder and that the lamp replacement cover has been screwed back into place Cleaning The most important part of your lighting effect to keep clean is the lens as this allows the light output to transmit This should be cleaned with a soft damp cloth The body of the unit may also be cleaned in the same way We recommend internal cleaning be carried out by a fully qualified technician Maintenance amp Servicing Work on internal parts should be carried out by a qualified technician Removal of any covers other than the lamp replacement cover and screw cap fuseholder is considered a breach of warranty and will not be covered under any such agreement unless authorized first by the company Technical Specifications Power 230 240V 50Hz AC Lamps 1 x 1500W Xenon Flash Tube Dimensions 507 x 204 x 130mm Weight 4 64kg This symbol on the product or on its packaging indicates that this product shall not be trated as household waste Instead it shall be handed over to the applicable collection point for the recycling of electrical an electronic equipme
4. ker that has protective functions as shortage and overloading Operation This lighting effect has been designed to function on a mains power supply of either 120V 60Hz or 230V 50Hz and has been fitted with a suitable power plug for use with your local voltage Check the label on the unit and the power plug for the correct voltage PA MARK BIG FLASH II 1500 User Manual Manual de Uso Pag 1 pea Before beginning operation refer to section on Installing Replacing Lamps When connected to the mains power supply turn on the circuit breaker the unit should begin to flash As the effect is controlled by the rotary speed control it may be necessary to adjust to suit your mood 1 4 mono plug allows for linking of strobes for operation via a strobe controller The duty cycle for this effect should be no more than 15 minutes on then 15 minutes of f Installation Mounting This unit has been designed to be hung It is recommended that for safety purposes your lighting ef fect be properly mounted using a suitable hanging clamp and safety cable Installing Replacing Lamps 1 Turn off and unplug from the electrical outlet and let the lamp cool 2 Open the rear cover with your screwdriver then disconnect the 3 wires of the old lamp from the PCB board Caution you must remember the wiring between lamp and PCB board 3 Gently remove the clear cover on the front of the STROBE via your screwdriver 4 CAUTION Do not touch bulb with bare fin
5. nt By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health which could otherwise be caused by inappropriate waste handling of this product The recycling of amterials will help to conserve natural resources For more detailed information sabout recycling of this product please contact your local city office your household waste disposal service or the shop where you purchased the product EAMARK BIG FLASH II 1500 User Manual Manual de Uso Pag 1 MA MARK BIG FLASH Il 1500 Manual de uso e Asas de montaje Panel trasero Control de velocidad e Jack mono 1 4 x 2 Para interconexi n e Magnetot rmico e Cubierta Mando dimmerizaci n Fig 1 Por favor lea estas instrucciones antes de usar la unidad Introducci n Felicidades por la adquisici n de nuestro efecto flash Para asistirle en el mantenimiento y uso de este producto hemos preparado este gu a Resoluci n de problemas e Si la unidad no funciona compruebe la alimentaci n y el estado del fusible e Si la unidad funciona pero la l mpara no se enciende sta necesita ser sustituida e Si a n contin a sin funcionar contacte con su distribuidor Precauci n No obstruya las tomas de aire No toque la unidad o la l mpara si a n est n calientes
6. s mbolo en su equipo o embalaje indica que el presente producto no puede ser tratado como residuos dom sticos normales sino que deben entregarse en el correspondiente punto de recogida de equipos electr nicos y el ctricos Asegur ndose de que este producto es desechado correctamente Ud est ayudando a prevenir las consecuencias negativas para el medio ambiente y la salud humana que podr an derivarse de la incorrecta manipulaci n de este producto EL reciclaje de materiales ayuda a conservar las reservas naturales Para recibir m s informaci n sobre el reciclaje de este producto contacte con su ayuntamiento su punto de recogida m s cercano o el distribuidor donde adquiri el producto PA MARK BIG FLASH II 1500 User Manual Manual de Uso Pag 1
7. to de fijaci n adecuado y un cable de seguridad Instalaci n y sustituci n de l mpara 1 Apague la unidad y descon ctela de la toma de red dej ndola enfriar 2 Abra la tapa trasera con un destornillador desconecte los 3 cables de la l mpara antigua en la placa Atenci n Recuerde como van conectados estos cables 3 Retire con cuidado la cubierta del flash con su destornillador 4 PRECAUCION No toque la l mpara con los dedos La grasa en los dedos puede estropear la l mpara Use un pa o seco para sustituir la l mpara Retire la l mpara antigua con cuidado de su portal mparas 6 Inserte una l mpara nueva y conecte los cables a la placa de acuerde al conexionado previo 7 Vuelva a montar la unidad al Finalmente antes de usar la unidad compruebe que la l mpara est firmemente sujeta y que la tapa est firmemente colocada Limpieza Lo m s importante es mantener limpias las lente que permiten transmitir la luz Deben ser limpiadas con un pa o suave Mantenimiento y Reparaci n La manipulaci n de los elementos internos de la unidad debe ser llevada a cabo por personal cualificado La retirada de cualquier otra tapa que no sea la de sustituir la l mpara se considera un quebranto de la garant a que no puede ser cubierta salvo previa autorizaci n Especificaciones T cnicas Alimentaci n 230 240V 50Hz AC L mpara Xenon 1 x 1500W Dimensiones 507 x 204 x 130mm Peso 4 64kg Este