Contents
1. 3 PIN 3 PIN IN OUT IN OUT Strobe 1 Strobe 2 3 pin IN and OUT socket 3 pin IN and OUT socket Smokecloak interface board Vali units Oli EEES ajo 1 388388355834 08 ajo 2 ma 2300 win E mang 5 2 201010 QQ s 191019 TS ajo 7 18 OO 8 17 OJ QQ 9 16 919 oo ho 2 PL3 15 010 ajo jm 14 0 9 2a 12 13LQ O el O O If you use more than 1 Strobe they can be linked via the 3 pin OUT socket to next 3 pin IN socket Strobe 1 Strobe 2 3 pin IN and OUT socket 3 pin IN and OUT socket 2951 A VALI INTERFACE TO MULTIPLE STROBE WIRING If you use more than 1 Strobe they can be linked via the 3 pin OUT socket to next 3 pin IN socket Parallel connection Parallel connection Supplier oroz Jenuef PE SmokeCloak gt Contact MSS Professional A S Brunbjergvej 6 DK 8240 Risskov Phone 45 7217 0011 Fax 45 8617 0055 MSS Professional Ltd Rectory Court High Street Kislingbury UK Northants NN7 4AG Phone 44 0 1604 839 000 Fax 44 0 1604 832 666 www smokecloak com
2. 15 Parallel CONNECHIONS LL 16 Strobe Measurements iii 17 Contents Warning This product is for professional use only It is not for household use The IPL 3000 presents risks of lethal or severe injury due to fire and heat electric shock ultraviolet radiation and falls Flashing light is also known to trigger epileptic seizures in persons who are photosensitive Read this manual before powering or installing the fixture follow the safety precautions listed below and observe all warnings in this manual and printed on the fixture To guard against electric shock Disconnect the fixture from AC power and allow the flash capacitor to discharge for 1 minute before changing the lamp or fuse and when not in use Always ground earth the fixture electrically Use only a source of AC power that complies with local building and electrical codes and has both overload and ground fault protection Do not expose the fixture to rain or moisture Replace the lamp only as described or have it replaced by a MSS Professional technician Safety information To guard against UV radiation burns and fire Never operate the fixture with the front glass open missing or damaged Do not stare directly into the light Never look at an exposed lamp while it is lit Replace the lamp when it becomes defective or worn out When replacing the lamp allow the fixture to cool for at least 1
3. 0 minutes before opening the fixture or removing the lamp Never attempt to bypass the fuse Always replace defective fuses with ones of the specified type and rating Verify that the power feed cable is rated for the current draw of all connected fixtures Keep all combustible materials for example fabric wood paper at least 0 5 metres 20 inches away from the fixture Keep flammable materials well away from the fixture Do not illuminate surfaces within 1 metre 39 inches of the fixture Provide a minimum clearance of 0 1 metres 4 inches around air vents Never place filters or other materials over the front glass cover The exterior of the fixture can reach temperatures up to 120 C 248 F Allow the fixture to cool for at least 15 minutes before handling Do not modify the fixture or install other than genuine MSS Professional parts Do not operate the fixture if the ambient air temperature Ta exceeds 40 C 104 F Safety information To guard against epileptic seizure Do not operate the fixture near stairways Provide advance notice that strobe lighting is in use See label below Preparation for use UNPACKING The IPL 3000 comes with the following items Philips XOP 15 OF or Xenon lamp installed Mounting bracket User manual The packing material protects the fixture during shipment always use it to transport the fixture AC POWER CONNECTION The aut
4. ach end Connect the wire with clear insulation the ionization wire to the inside terminal on the end closest to the mains cable Push the insulation for each wire as far as it will go into the connection block 6 Lift and turn the lamp over so that the leads loop around the ends as shown then press the lamp into the clips 7 Close the front cover and replace the side screws before applying power Lamp 13 This section describes how the IPL 3000 operates STAND ALONE FLASH RATE To program stand alone execution Apply power to the fixture 2 Set pin of the Mode DIP switch to ON Set pins 2 5 to OFF Set pin 6 to ON for low power op eration or to OFF for high power operation 3 Select Flash rate DIP switch settings for security use Address Mode 50 Hz 0 a ja al i al c 1 2 3 4 5 6 7 8 9 10 1234556 ON ON Address Mode ns ja et iL G a a e 0 0 E a 12 3 4 5 6 7 8 9 10 123 4 5 6 ON ON 4 Set DIP switch pin 10 to OFF for normally off operation or to ON for normally on operation 14 Installation Warning High voltage Do not remove the rear panel There are no userserviceable parts inside FUSE REPLACEMENT The IPL 3000 uses a 20 amp time delay fuse for prot
5. ce to illuminated surfaces m 39 in Minimum clearance around fan and air vents 0 1m 4 in Specifications Smokecloak interface board System units 200000000 ES OO Strobe 3 pin IN socket Smokecloak interface board Vali units SEE manna ajo 1 38535355354 0 0 2 23 0 0 QO 3 22 PL1 PL4 elo Pp 21 0l 5 20 OI QO 6 191 OD ES ES Qo 7 18 OI olo ls 17 018 IN QO 9 16 O PL2 PL3 DO 10 15 O Strobe 3 pin IN socket 11 14 OI 112 13 LOJ O O VALI INTERFACE TO STROBE WIRING The Strobe can be connected directly to the alarm panel or to the Smokecloak When pins 1 and 3 N O are connected together the strobe will activate If the Smokecloak option of separate mains failure out put 23 24 is not being used connect as above If the separate mains failure output is being used then trigger the strobe by using an output from the alarm panel Strobe Connections to a Smokecloak 17 18 Smokecloak interface board System units
6. ection against current overload If the power diode does not light when power is applied the fuse may have failed If the fuse blows repeatedly there is a fault with the unit that requires service by a MSS Professional technician Never bypass the fuse or replace it with one of another size or rating Replacement fuses may be ordered by P N 05020040 To replace the fuse 1 Disconnect the fixture from AC power 2 Unscrew the fuse holder located on the side plate nearest the power cord Remove the failed fuse from the holder and replace it with an identical 20 amp 6 3 x 32 mm time delay fuse 3 Replace the fuse holder in the side plate Service 15 16 PHYSICAL Size without bracket 245 X 425 x 240 mm 9 7 X 16 7 x 9 5 in ET EEE 7 5 kg 16 5 lb THERMAL Maximum ambient temperature 40 C 104 F CONTROL Signal INpuUti ii Switch or relay between Pin 1 and 3 AC SUPPLY ANEINANDER een 2 5 mma trailing cable AC voltage and frequency range XOP 15 OF Model i 125 260 V 50 60 Hz Peak current consumption i 33 A Typical current consumption XOP 15 OF high power mode 8A FUSES Primary FUSE 20 AT 250 V P N 05020040 CONSTRUCTION FOSNES ruan toa pari steel RE ande eandres electrostatic powder coating black MOUNTING Minimum distance to combustible materials 0 5 m 20 in Minimum distan
7. en SmokeCloak lt NNN User Manual IPL 3000 IPL 3000 user manual Manual IPL 3000 n TOUI Please read this manual carefully before attempting to install an IPL 3000 IPL 3000 user manual Every effort has been made to ensure that the contents of this manual are correct MSS Professional does not accept any liability for loss or damage caused or alleged to be caused directly or indirectly by this manual The contents of the manual may be subject to change without notice MSS Professional makes no warranty of any kind with regards to this material 2005 MSS Professional Reproduction in any matter whatsoever without the writ ten permission of MSS Professional is strictly forbidden Smokecloak is a registered trademark Smokecloak is protected by Patent Nos 2270396 5394139 0659293 and 93 6722 February 2005 Ref MSS590C MSS Professional A S MSS Professional Ltd Brunbjergvej 6 Rectory Court High Street 8240 Risskov Kislingbury Denmark Northampton Northants Telefon 45 7217 0011 NN7 4AG Fax 45 8617 0055 England Phone 44 0 1604 839000 Fax 44 0 1604 832666 IPL 3000 user manual Contents Safety information iii 4 Preparation for USE nn 7 A ee 10 Installation eee eee ee ee eee eee eee eee eee a R el are 12 SENICE o o o nn 13 Specifications nennen 14 Strobe connections to a Smokecloak
8. g bracket stud 3 Place one end of the bracket on on of the mounting studs Bend the other end of the mounting bracket open slightly and work it onto the opposite stud 4 Place a hand knob on each stud Tighten both hand knobs to lock the mounting bracket in place 8 security STROBE 8 Specifications 1 12 This section describes how to replace the lamp The lamp is electronically regulated to prevent overheating LAMP REPLACEMENT End of life can be confirmed with the flash LED on the rear panel The LED flashes dimly with each trig ger pulse if the LED lights but there is no flash from the lamp the lamp is spent If the LED does not flash their may be a problem with the control signal To replace the lamp Warning Verify that the fixture is disconnected from AC power before opening the front cover 1 Very important Before opening the unit discon nect from mains electricity and wait for at least 1 minute for the capacitor to discharge 2 When the fixture is cool remove the two marked screws on the sides of the fixture and open the front glass cover 3 Disconnect the lamp wires at the screw termi nals Lift the old lamp out of the holder 4 Lay the new lamp on the front glass above the lamp clips with the end with 2 wires on the side closest to the mains cable Lamp 5 Important Connect the two wires with white insulation the electrode wires to the outside terminal on e
9. o ranging power supply automatically adjusts to any 50 60 Hz AC power supply from 125 to 260 volts No adjustment is necessary The current required by the IPL 3000 varies according to power mode and usage Use 2 5 mm2 13 AWG or larger power feed cables and keep runs as short as possible The mains lead must be fitted with a heavy duty cord cap with ground connection Consult a qualified electrician if you have any doubts about proper installation Preparation for use Following the cord manufacturer s instructions connect the yellow and green wire to ground earth the brown wire to live and the blue wire to neutral The table below shows some pin identification schemes Screw color Marking yellow or brass blue neutral silver N yellow green ground A green Table 1 Cord cap wiring INSTALLATION Before installing verify that the fixture will be located at least 1 meter 39 in away from the surface to be illuminated at least 0 5 meters 20 in from any combustible materials and well away from flammable materials the clearance around the air vents is at least 0 1 meters 4 in and no one is located under the work area Specifications The IPL 3000 may be installed in any orientation The mounting bracket provides five 12 mm holes for direct fastening To install the mounting bracket 1 Place the fixture face down on a table 2 Place a plastic washer on each mountin