Home
User`s Manual - CODE Electronic Co., Ltd.
Contents
1. signal connectors C lt FROM CONTROLER EU o 3 Signal TO OTHER DIMMER DMX512 OUT 6 2 Connecting With A Console DMX CONTROLLER DMX OUT DMX DMX OUT DM66 S 1 DMX DMX IN OUT DM66 S 2 DMX DMX OUT DM66 S 3 7 Confirming DMX 512 Local Inception Address Number DIP switch s position function ON obtains its bit value OFF its bit value is 0 The relation between bit value of DIP encoder and DMX channel code keeps to the formula below The sum value of 1 9bit switches of DIP encoder 1 DMX inception address number Bit value of DIP switches CEE A O ee vme 2 EI HEER For example A console connects with four DM62 S dimmer sets Every set ties up number of 6 channels Thus we must confirm DMX inception address number of every set by DIP switches as follow table me A 8 Confirming Output State Memory Mode Confirming the output state memory mode of CODE DM66 S by No 10bit switch of DIP encoder When the position of No 10bit switch is A moved at downside this set is in data memory state lt means of DMX 512 control signal broken off abruptly the current output state of every channel is not changed Whereas the position of No 10bit switch is B moved at upside the data memory function is closured It means of DMX 512 control signal broken off abruptly then every channel outputs zero 9 operatio
2. CODE 6 Channels Digital Dimmer Pack User s Manual CODE ELECTRONIC CO LTD Welcome to use CODE DM66 S Digital Dimmer Pack CODE DM66 S meets DMX 512 1990 standard digital control signal It is suited for using with a console that generates DMX 512 1990 control signal thereby them constitute a digital light dimming control system DM66 S s EMI is very low So greatly it is used for light dimming in TV studios theatres troupes danceries etc 1 Specifications Dimming Channel 6 Channels 30A max per channel Control Signal DMX 512 1990 standard digital signal EMI Restraining High efficiency EMI Choke Power Supply Three phase single phase 220V 50 60Hz Fa Channel Protecting Miniature circuit breakers 32Amps Standby Wasting 27 Watts approx Cooling n 482mm W x 133mm H x 455mm D _ 19 standard 3U Weight 17 6kg 2 Front Panel And Rear Panel Devices 8 1 12 000000 om Y s r 4 romen w 14055 CODE o elelelelel me Seite BBBBBE Sa i A z 5 es wee wu oo o Nun DG S s EEN urian 10 DIP encoder setup DMX 512 inception address number select data memory mode DMX 512 signal input pilot light Channel output state pilot light Dimming Keys UP Dimming Keys DOWN Miniature circuit breakers For Channel Protecting Switch for operation power supply PO NOAR YON A Fuse for operation power supply 9 Connector f
3. n power Supply Switch POWER This switch turns on or turns off the operation power supply which powers for MPU unit of CODE DM66 S Digital dimmer pack l turn on O turn off When the switch is turned off the inner thyristor circuits are lived all the same In this time do not open the casing of the set for preventing electric shock 10 DMX 512 Signal Input Pilot Light SIGNAL The pilot light is twinkling while receiving normal DMX 512 signal Otherwise it is blank While it is blank please check the console the cable the connectors the polarity of DMX512 signal 11 Channel Output State Pilot Light The brightness of every pilot light denotes its channel output intensity 12 Output Circuit Protecting A Miniature circuit breakers is in every output circuit of CODE DM66 S Every switch is 32Amps While the output over current or the output terminals be short circuit the switch will cut off immediately for protecting this channel 13 Independent Dimming Function Every channel can dim the lamps independently by UP DOWN keys without any console 14 The Set Running Connecting and setting up DM66 S dimmer correctly turning on the operation power supply of the console and this set then system starts running We may change the local inception address number and or output state memory mode by DIP switches at any moment MEMO
4. or DMX 512 digital signal input XLR D3M 10 Connector for DMX 512 digital signal thru output XLR D3F 11 Terminals for 6 channel loads 12 Terminals for power supply net input 3 phase 4 wire and earth CONNECTION amp OPERATION 3 Contents Checking One CODE DM66 S set and one User s Manual in the package 4 Power Supply Connecting This set is suitable to three phase or single phase Power supply 4 1 Single Phase Power Supply Connecting Connect the live wire of single phase power supply to L1 L2 and L3 all together connect the neutral wire to NE and connect the safe earth to GND 4 2 Three Phase Power Supply Connecting Connect the A B C live wires of three phase power supply to L1 L2 and L3 respectively connect the neutral wire to NE and connect the safe earth to GND 5 Loads Connecting GND NE 13 12 Li 3 PHASE CONNECTIONS Connect the live wire of every circuit to the output terminal of CODE DM66 S respectively connect the neutral wires of the circuits to NE terminals of this set The connection mode is showed as follow sketch map PORWER OUTPUT 30A per channel 6 Connecting With A Console CODE DM66 S Digital Dimmer Pack can be controlled by a console that generates DMX 512 digital signal The control signal connection mode is showed as follow sketch maps 2 6 1 DMX
Download Pdf Manuals
Related Search
Related Contents
YAK-54 EXP - Extreme Flight RC Estimating the Abundance of Arboreal Forage Lichens: User's Guide Desa CLD3924NTA Electric Heater User Manual TPI-1001-A User Manual - RF Depliant - Delta Ohm S.r.l. Copyright © All rights reserved.
Failed to retrieve file