User`s manual “VENTS domestic fans” ( PDF 424,91Kb )
Contents
1. Type a b Cae D e 100 D D1 150 120 108 93 100 12 125 D D1 176 140 114 96 125 13 150 D D1 205 165 132 150 15 Mounting on air duct from air charging side series fans D1 Type a b c D e 100 M 160 135 90 100 25 125 M 180 150 94 125 25 150 M 207 182 106 150 25 Mounting on air duct from air charging side Type a b c D e 100 MA M1 166 150 90 100 30 125 MAM1 186 170 94 125 30 150 MA M1 207 187 110 150 30 Mounting on air duct from air charging side MA supplied with automatically opening louvers Type a b e c D g h 125 MAO1 186 173 60 53 125 125 MAO2 186 173 60 125 123 160 150 MAO1 210 195 66 60 150 150 MAO2 210 195 66 150 156 183 Mounting on the windows OQO VENTS VENTS 100 LD VENTS 125 LD VENTS 150 LD VENTS 100 LD1 VENTS 125 LD1 VENTS 150 LD1 LD and LD1 series fans of all modifications VENTS 100 S VENTS 125 S VENTS 150 S VENTS 100 S1 VENTS 125 S1 VENTS 150 S1 S and S1 series fans of all modifications VENTS 100 PF VENTS 125 PF VENTS 150 PF VENTS 100 PF1 VENTS 125 PF1 VENTS 150 PF1 D D D1 b b PF and PF1 series fans of all modifications VENTS 100 F VENTS 125 F VENTS 100 F1 VENTS 125 F
2. Type ala D1 D D c l 100 VKO VKO1 85 113 104 100 98 32 30 125 VKO VKO1 85 118 129 125 123 32 30 150 VKO VKO1 105 128 154 150 148 48 30 Mounting inside air duct connected on both sides series fans VKO1 Type E g h f 100 VKOk VKO1k 160 144 29 45 125 VKOkK VKO1k 185 169 29 45 150 VKOkK VKO1k 200 184 29 45 Supplied with mounting corbel for mounting to flat surface Type a b c c D e e 100 K K1 154 110 100 104 100 15 19 125 K K1 187 142 100 104 125 15 19 150 K 250 214 118 150 15 series fans K1 Mounting on air duct from air charging side Supplied with detachable K or K1 type grille on air suction side Type a b c D e f g 100 M3 188 155 85 100 30 256 226 125M3 188 155 91 125 30 256 226 150 M3 188 155 115 150 30 256 226 Mounting on air duct from air charging side QYVENTS VENTS 100 D VENTS 125 D VENTS 150 D VENTS 100 D1 VENTS 125 D1 VENTS 150 D1 D and D1 series fans of all modifications VENTS 100 M VENTS 125 M VENTS 150 M M series fans of all modifications VENTS 100 MA VENTS 125 MA VENTS 150 MA VENTS 100 M1 VENTS 125 M1 VENTS 150 M1 MA and M1 series fans of all modifications VENTS 125 MAO1 VENTS 150 MAO1 VENTS 125 MAO2 VENTS 150 MAO2 MAO1 and MAO2 series fans table 1 of all modifications Oa a o Jo
3. the delay time and humidity level respectively To set the maximum humidity level the potentiometer H has to be set in position H max 90 Attention eH rightmost If during regulation the potentiometer H is set outside of the indicated zone Position rightwards from H max see picture there is a probability that the fan will not switch on In this case itis necessary to check the position of the potentiometer Fan with timer and movement sensor switches on when a person moves at the distance from 1 till 4 meters with viewing angle of the sensor of 100 horizontally After the person stops moving the fan continues working during the set time T which is regulated from 2 till 30 min The time T is regulated by turning the potentiometer T clockwise to increase and anticlockwise to decrease the delay time Attention Diagram of timer is situated under mains voltage Any regulations have to be made only when the fan is switched off the mains Diagram in Fig 15 shows connection of lighting lamp to fan s timer controlled by single switch S is an external switch When lightning lamp is off fan continues working during the time set by timer only for 12 V fans mentioned on the fan s body and fan s box QV ENTS x MAINTENANCE Fan maintenance should be performed only after switching off mains Maintenance chiefly consists of periodic cleaning of the fan s surfaces of duct and dirt The fan should be cleaned with soft cloth w
4. 1 F and F1 series fans of all modifications table 1 Type a b c c D e 100 LD LD1 150 120 126 111 100 30 125 LD LD1 176 140 134 116 125 30 150 LD LD1 205 165 153 150 30 Mounting on air duct from air charging side series fans LD1 Type a b cle D e 100 S S1 150 120 108 93 100 12 125 S S1 176 140 114 96 125 12 150 S S1 205 165 132 150 13 Mounting on air duct from air charging side series fans S1 Type a b b D D D1 100 PF PF1 12 99 127 100 99 141 125 PF PF1 14 100 134 125 123 166 150 PF PF1 15 116 146 150 146 188 Mounting on air duct from air charging side series fans PF1 Type a els Dy S 1Byl f g 100 F F1 182 160 99 127 100 99 10 141 252 226 125 F F1 182 160 100 134 125 123 10 166 252 226 Mounting on air duct from air charging side series fans F1 QYVENTS VENTS 100 X VENTS 125 X VENTS 150 X X series fans of all modifications VENTS 100 X1 VENTS 125 X1 VENTS 150 X1 X1 series fans of all modifications VENTS 100 Xstar VENTS 100 R R series fans of all modifications VENTS 100 R1 R1 series fans of all modifications table 1 Type a b c D g 100 X 151 96 30 100 120 125 X 178 101
5. 30 125 140 150 X 204 117 30 150 165 Mounting on air duct from air charging side Type a b c D g 100 X1 151 96 12 100 120 125 X1 178 101 13 125 140 c 150 X1 204 117 14 150 165 Mounting on air duct from air charging side Type a b c D g 100 Xstar 151 96 31 100 120 Mounting on air duct from air charging side Type a b c D h 100 R 150 122 89 98 36 Mounting on air duct from air charging side Type a b c D h 100 R1 150 122 89 98 25 Mounting on air duct from air charging side QYVENTS M D D1 Xstar S S1 M1 M3 LD LD1 X X1 series fans can be supplied with back valves At that dimention of case outlet capacity of fan is 14 mm longer fan back valve SET OF SUPPLY The following articles are included in the supplied set Fan 1pc User s manual Packing box Screws 4pcs except models 100 125 150 VKO VKO1 sealing gasket 2 pcs for models 125 150 MAO1 MAO2 tie bolt 2 pcs for models 125 150 MAO1 MAO2 SAFETY REQUIREMENTS The fan VENTS complies with the requirements according to the EU norms and directives to the relevant EU Low Voltage Equipment Directives EU Directives on Electromagnetic Compatibility Level of protection from access to hazardous parts and waterproof IPX4 VKO VKO1 IP24 MA Xstar R R1 MAO1 MAO2 X X1 series IP34 K K1 D D1 M PF PF1 M1 M3 F1 S S1 F LD LD1 series Connection of fans supplied without electric cords to power suppl
6. IES DOMESTIC RIC FANS QYVENTS DESIGNATION VENTS fans are designed for ventilation of domestic and similar premises apartments offices stores garages kitchens bathrooms toilets and other rooms heated in wintertime Fans but for VKO VKO1 series are exhaust fans and are designed for wall or ceiling mounting MAO series fans are to be installed in windows VKO VKO1 series fans may be used for both input and output ventilation and are to be installed in ventilation ducts VENTS fans are designed for continuous work without switching off mains Design of the fans is constantly improved and updated and some models may differ from what is described in this manual BASIC SPECIFICATIONS Fans identification diagrammatic representation of appearance installation dimensions and peculiarities of design are given in Table 1 The fans are designed for operation from AC power supply with voltage of 220 240 V and frequency of 50 Hz or 12 V and frequency of 50 Hz depends upon the model Nominal output in terms of extract air capacity is for fans with 100 mm outlet capacity 55 107 m h 5 for fans with 125 mm outlet capacity 108 232 m h 5 for fans with 150 mm outlet capacity 220 348 m h 5 Nominal electric power of the fans is for fans with 100 mm outlet capacity 5 3 22 W for fans with 125 mm outlet capacity 9 1 26 W for fans with 150 mm outlet capacity 20 32 W Equalize
7. d sound level at 3 m distance does not exceed 40 dBA Fans are designed for operation at air temperature within 0 C to 45 C Durability not less than 5 years GY VENTS XXXXXXXXXXX IDENTIFICATION 100 125 150 outlet capacity of the fan VKO VKO1 M MA M1 M3 MAO1 MAO2 K K1 indication PF PF1 D D1 Xstar R R1 S S1 F LD LD1 F1 X X1 of fan series V supplied with switch T supplied with timer TH supplied with timer and humidity relay TP supplied with timer and motion sensor K supplied with back valve L motor with ball bearings turbo press 12 low voltage motor 12 V Q quiet operation motor Example of symbolic notation VENTS 125 DVTK fan with 125 mm outlet capacity D series supplied with switch timer back valve OQO VENTS VENTS 100 VKO VENTS 125 VKO VENTS 150 VKO VENTS 100 VKO1 O VENTS 125 VKO1 VENTS 150 VKO1 VENTS 100 VKOk VENTS 125 VKOk VENTS 150 VKOk VENTS 100 VKO1k _ VENTS 125 VKO1k VENTS 150 VKO1k VKO k and VKO1 k series fans of all modifications VENTS 100 K VENTS 125 K VENTS 150 K VENTS 100 K1 VENTS 125 K1 Oa y E E K and K1 series fans of all modifications VENTS 100 M3 VENTS 125 M3 VENTS 150 M3 M3 series fans of all modifications table 1
8. dicated in Tab 2 Fans Identification Operations of connection to power supply VENTS VKO VENTS VKO1 Remove protective grid except model VENTS VKO VENTS K Take away a protective cowl Pass power supply cords VENTS K1 through a hole 3 smooth out wire rags at length 7 8 mm VRNE Ea to clamp terminals 4 agaist stop to the metal part of the VENTS F clamp and tighten them with screws Fix cords with the VENTS F1 help of clip 2 Reinstall protective cowl and grid back VENTS M Remove protective grid and cover Pass power supply cords VENTS M1 through a hole 3 having cut a thin plastic pierce on the spot VENTS M3 of opening beforehand Smooth out wire rags at length 7 8 VENTS MA mm to damp terminals 4 agaist stop to the metal part of the VENTS MAO1 clamp and tighten them with screws Fix cords with the help VENTS MAO2 of cip 2 Reinstall cover and protective grid back VENTS Xstar Remove protective grid and cover Pass power supply cords VENTS D through a hole 3 having cut a thin plastic pierce on the spot alti ial of opening before hand Smooth out wire rags at length 7 8 VENTS S1 mm to clamp terminals 4 agaist stop to the metal part of the VENTS LD clamp and tighten them with screws Place power supply VENTS LD1 cords into housing grooves and fix them in fastening support VENTS X Reinstall cover and protective grid back VENTS X1 Take off a decorative front facia for models R Open a cover of terminal compartment Put the w
9. etted in soapy water After cleaning the surfaces should be wiped dry STORAGE Fan should be stored in original manufacturer s container at a temperature within 5 C and 40 C and relative air humidity not more than 80 at T 25 C WARRANTY Fans are manufactured at the factory of Ventilation systems JSC in compliance with European norms and standards at force Manufacturer hereby guarantees normal performance of the fan over 60 months since the date of its sale via retail commercial network subject to adherence to the rules of transportation torage assembling and operation In case of unavailability of indication of the fan s sale date the warranty term is calculated from the date of manufacture In case of occurrence of faults in operation of the fan through the fault of the Manufacturer within the warranty term consumer shall be eligible for free repair of the device or its replacement at manufacturing enterprise in accordance with relevant provisions of article 14 9 of the Law of Ukraine On Protection of Consumer s Rights Warranty replacement is performed by Manufacturer at 01030 Kyiv 1 M Kotsiubynskyi Str or by Seller ACCEPTANCE CERTIFICATE The fan has been duly certified as serviceable Model Manufactured on date VENTS Approval mark Sold Name of trading enterprise stamp of store Date of sale VO1EN 14
10. ires through an opening 2 having cut a thin plastic cover on the opening beforehand VENTSR Skin the ends of the wires for 5 7 mm set them in the VENTS R1 terminal 1 up to the stop of the isolation into metal part of the terminal and fix them with screws Set the power wires i n the terminal compartment Close the cover of the terminal compartment Mount the front facia for models R table 2 For fans without switch it is advisable to install power supply switch on fixed power supply wiring Diagram of connection of fan to fixed power supply wiring is shown in Fig 12 17 GYVENTS picture 3 1 housing 2 clip of power supply cords 3 holes for power supply cords 4 clamp terminal 5 holes for fan mounting 1 housing 2 clip of power supply cords 3 holes for power supply cords 4 clamp terminal 5 holes for fan mounting 6 timer timer with humidity sensor 7 pull cord switch 1 housing 2 clip of power supply cords 3 holes for power supply cords 4 clamp terminal 5 holes for fan mounting 6 timer with motion sensor 7 potentiometer T M M3 series fans with removed cover M M3 series fans with removed cover Models T TH V VT VTH M M3 series fans with removed cover Models TP ATTENTION for fans with motion sensors The front cover of the fan must be uncovered only from the side of the motion sensor GYVENTS pict
11. of power supply cords 3 holes for power supply cords ATTENTION 4 clamp terminal 5 holes for The front cover of the fan for fans with motion sensors fan mounting must be uncovered only from 6 timer and the side of the motion sensor motion sensor 7 potentiometer T RS WE r Xstar series fans with removed cover 1 housing 2 clamp terminal 3 lamp terminal block 4 socket 5 clip of power supply cords 6 holes for fan mounting R R1 series fans with removed decorative cover plate fascia and gags Models T TH V VT VTH 1 terminal block 2 holes for power supply cords 3 potentiometer T 4 potentiometer H 5 holes for fan mounting 6 screws to fix fan into duct 7 housing QYVENTS 12 picture 12 i S gt Phase O H 220 240 V 12 V oe Siig Power supply feed circuit for fans with built in switch picture 13 iS J gt Phase 220 240 V 12 V tp Diagram of connection of fan without built in switch to circuit where 8 is switch installed additionally picture 14 ji menace LT 220 240 V 12 V N gt o Diagram of connection of fan equipped with timer timer with humidity relay and built in switch 13 picture 15 L Phase Sa RI N S 220 240 V 12 V car Diagram of connection of fan equipped with timer timer with humidity relay and without built in switch L eo Sb LN O Le
12. oma picture 16 Phase 220 240 vpe ye lo S1 external switch of fan S2 external switch of lamp Electrical connection of X star fan when fan and lighting can be switched separately i S picture 17 B L Phase N 220 240 V 12 V m d i L 8 S external switch Electrical connection of X star fan when fan and lighting can be switched at the same time QY VENTS Diagrams in Fig 12 14 show operation of fans equipped with built in switch Diagrams in Fig 13 15 show connection of fans without built in switch S external switch Electrical connection of X star fan is shown in Fig 16 17 Fan with timer option switches on when the voltage is supplied to clamp LT After the voltage is disconnected the fan continues working during the set time T which is regulated from 2 till 30 min The time T is regulated by turning the potentiometer clockwise to increase and anticlockwise to decrease the delay time Fan with timer and humidity sensor switches on when the voltage is supplied to clamp LT or when the definite humidity level regulated from 60 till 90 is exceeded After the voltage is disconnected or humidity level H is decreased the fan continues working during the time set by timer T which is regulated from 2 till 30 min The options of time T and humidity H are regulated by turning the potentiometers T and H clockwise to increase and anticlockwise to decrease max
13. ure 4 picture 5 picture 6 VKO VKO1 F1 K K1 PF PF1 F series fans with removed cover 1 housing 2 clip of power supply cords 3 holes for power supply cords 4 clamp terminal D D1 S S1 LD LD1 X X1 series fans with removed cover 1 housing 2 clip of power supply cords 3 holes for power supply cords 4 clamp terminal 5 holes for fan mounting 6 lead fixing rack D D1 S S1 LD LD1 X X1 series fans with removed cover Models T TH V VT VTH 1 housing 2 clip of power supply cords 3 holes for power supply cords 4 clamp terminal 5 holes for fan mounting 6 lead fixing rack 7 pull cord switch 8 potentiometer T 9 potentiometer H GYVENTS ii picture 7 picture 8 picture 9 11 M1 MA MAO1 MAO2 series fans with removed cover Models T TH 1 housing 2 clip of power supply cords 3 holes for power supply cords 4 clamp terminal 5 holes for fan mounting 6 potentiometer T 7 potentiometer H M1 MA MAO1 MAO2 series fans with removed cover Models V VT VTH 1 housing 2 clip of power supply cords 3 holes for power supply cords 4 clamp terminal 5 holes for fan mounting 6 pull cord switch 7 potentiometer T 8 potentiometer H M1 MA MAO1 MAO2 series fans with removed cover Models TP 1 housing 2 clip
14. y as well as replacement of electric cord should be performed by skilled electrician Fan operation beyond the operational temperature range as well as in rooms with ambient air containing aggressive admixes is prohibited ATTENTION Fan operation when restirictions being able to damage or jamm blades of operation wheel are in flowing part of case is prohibited Precautions must be taken to avoid the black flow of gases into the room from the open flue of gas or other fuel burning appliances O MENTS PREPARATION TO DEVICE OPERATION Attention All maintenance works and connection of fans are to be performed only after switching off mains Connection of fans to electric power supply must be performed only through switch with actuation length not less than 3 mm at all poles Direction of air charging is to comply with direction of arrow on the fan case VENTS VKO VKO1 fans are mounting in ventilation air ducts from both ends and nipped with clamps VENTS MAO1 MAOZ2 fans are mounting on the windows Fans of other models are inserted in the hole of the air duct and mounted on the wall or ceiling with dowels If necessary ensure conditions to prevent free access to impeller and current carrying parts of fan by protective means from side of outcome ventilation grille protective cowl and so on Connection of fans to electric power supply is shown in Fig 1 11 An order in which connection of fans should be made is in
Download Pdf Manuals
Related Search
Related Contents
Samsung SGH-E786 Manual de Usuario Philips PR 1309B Handheld TV User Manual ASUSTOR USER GUIDE Metria™ IH1 User Manual TS Quick Start Guide v6 ZTE AXON User Manual (1) Alarm Systems - Department of Business and Professional ImageQuant™ LAS 500 - GE Healthcare Life Sciences (M)SDS - 純正化学株式会社 製品検索・MSDS検索 Copyright © All rights reserved.