MINICUBE2 Diagnostic Tool MINICUBE Utility UM
Contents
1. User s Manual MINICUBE2 Diagnostic Tool MINICUBE Utility Target Devlopment Tool QB MINI2 Document U18588EJ2VOUMOO 2nd edition Date Published October 2008 NS NEC Electronics Corporation 2007 Printed in Japan MEMO 2 User s Manual U18588EJ2VOUM MINICUBE is a registered trademark of Electronics Corporation in Japan and Germany Windows is either a registered trademark or a trademark of Microsoft Corporation in the United States and or other countries The names of other companies and products are the registered trademarks or trademarks of their companies The information in this document is current as of October 2008 The information is subject to change without notice For actual design in refer to the latest publications of NEC Electronics data sheets or data books etc for the most up to date specifications of NEC Electronics products Not all products and or types are available in every country Please check with an NEC Electronics sales representative for availability and additional information e No part of this document may be copied or reproduced in any form or by any means without the prior written consent of NEC Electronics NEC Electronics assumes no responsibility for any errors that may appear in this document e NEC Electronics does not assume any liability for infringement of patents copyrights or other intellectual property rights of third parties by or arising from the use of NE
2. 2 1 SELF TEST and F W tabs The self testing and firmware download functions can be switched 2 EXIT button Terminates the MINICUBE2 diagnostic tool 10 User s Manual U18588EJ2VOUM CHAPTER 3 SELF TESTING FUNCTION This section explains how to perform self testing of MINICUBE2 3 1 Explanation of Each Area The following window is displayed by clicking the SELF TEST tab Explanation of each area is described below 1 RE MINICUBE Diagnostic Tool SELF TEST FN MINIGUBE Information D TMPEMOB2UTL log 1 MINICUBE2 Information window Displays MINICUBE2 hardware information and the firmware version 2 Test status Displays the log file name until the path is changed or self testing is performed Displays the test items during self testing Displays the test result after self testing is completed 3 log button When this button is clicked the path for the log file can be changed 4 START button When this button is clicked a confirmation dialog box appears and self testing is started by clicking the OK button 5 Progress bar The upper progress bar indicates the progress status of the test currently being performed The lower progress bar indicates the status of progress for overall self testing Users Manual U18588EJ2VOUM 11 CHAPTER 3 SELF TESTING FUNCTION 3 2 Cautions on Self Testing Note the following points when executing the self testing function e Do not connect M
3. Close Alt F4 About MOBZUTL A 2 log Click About MQB2UTL A on the system menu the version information window then appears RE MINICUBE Diagnostic Tool Alt F4 About MOBZUTL MOB2UTL MGOB2LITL Version Vx xx dd mm yyyy CopyrighttG NEC Electronics 2006 User s Manual U18588EJ2VOUM CHAPTER 6 UNINSTALLATION This section explains how to uninstall the MINICUBE2 diagnostic tool Note the following points when uninstalling the MINICUBE2 diagnostic tool e The MINICUBE OCD Checker is uninstalled at the same time e The log files are not deleted by uninstalling the MINICUBE2 diagnostic tool Perform uninstallation according to the following steps 1 to 5 1 Turn on power to the host machine and start Windows 2 Start Add Remove Programs or Add or Remove Programs the Control Panel 3 Select the relevant item from the list displayed on the Install Uninstall tab and then click the Add Remove or Change Remove button e uninstall the MINICUBE2 diagnostic tool NEC EL MINICUBE Utilities e To uninstall this document NEC EL MINICUBE Utilities Vx xx Documents 4 A dialog box for confirming deletion of files will be displayed Click the Yes button deleting the files will then be started 5 When the completion message is displayed click the OK button This completes uninstalling the MINICUBE2 diagnostic tool User s Manual U1858
4. Caution If multiple debuggers are installed MINICUBE Utilities Vx xx MINICUBE2 Diagnostic Tool in the Latest Version folder is overwritten Remark MINICUBE OCD Checker is installed when the MINICUBE2 diagnostic tool is installed R 2 1 2 Startup Start the MINICUBE2 diagnostic tool using either of the following procedure e When using CubeSuite Click the Start menu of Windows point to Programs NEC Electronics CubeSuite Emulator Utilities Target Device gt and then click MINICUBE2 Diagnostic Tool e When using the ID850QB ID78K0 QB ID78KOS QB ID78KOR QB or QB Programmer Click the Start menu of Windows point to Programs NEC Electronics Tools Latest Version and then click MINICUBE Utilities Vx xx MINICUBE2 Diagnostic Tool Caution If the debugger QBP or MINICUBE OCD Checker is running terminate it before starting the MINICUBE2 diagnostic tool 8 User s Manual U18588EJ2VOUM CHAPTER 2 INSTALLATION AND STARTUP 2 2 When Tools Manufactured by Partner Companies GHS and IAR are Used 2 2 1 Installation e Download MINICUBE Utilites MINICUBE Utilities Vxxx lzh from one of the following websites http www necel com micro ghs jpn exec execindex html Japanese version http www necel com micro ghs eng exec English version 1 Download MINICUBE Utilities Vxxx Izh into an arbitrary folder from the website 2 Execute MINICUBE Utilities Vxxx lzh in the arbitrary folder 3 The
5. Self checking is aborted Please power off the MINICUBE2 either remove the 78K0 OCD Board or select M2 of the mode selection switch then restart self checking This message is displayed when the 78K0 OCD board is connected while the mode select switch is set to M1 Turn off the power to MINICUBE2 and then set the switch to M2 or remove the 78K0 OCD board 4 Communication Error Self checking is aborted This message is displayed when a communication error occurs between the host machine and MINICUBE2 during self testing Check if the USB cable is disconnected MINICUBE2 USB connect error This message is displayed immediately after MINICUBE2 is connected to the host machine before the LED glows Possible causes are MINICUBE2 is not connected to the host machine the USB cable is disconnected or the MINICUBE2 USB driver has an error Check if the USB cable is disconnected Debugger already running Self checking is aborted This message is displayed when the MINICUBE2 diagnostic tool and the debugger are running at the same time Terminate the debugger If an error message other than above is displayed the cause may be a defect in MINICUBE2 If the same error message is displayed even after the above action is implemented the cause may be a defect in MINICUBE2 In such a case consult an NEC Electronics sales representative or distributor 20 User s Manual U18588EJ2VOUM CHAPTER 4 FIRMWARE DOWNLOAD FUNCTION Thi
6. developed or manufactured by or for NEC Electronics as defined above M8E 02 11 1 User s Manual U18588EJ2VOUM 3 Target Readers Purpose Organization How to Read This Manual Conventions INTRODUCTION This manual is intended for users who use the MINICUBE2 diagnostic tool when designing and developing a system using an NEC Electronics on chip flash memory microcontroller This manual is intended to give users an understanding of the basic specifications and correct use of the MINICUBE2 diagnostic tool This manual includes the following sections e Overview e Installation and startup e Self testing function e Firmware download function e Version indication e Uninstallation It is assumed that the readers of this manual have general knowledge of electricity logic circuits and microcontrollers In the explanations of the operation of the applications it is also assumed that the readers have sufficient knowledge of Windows For the usage and terminology of Windows 98 Windows Me Windows 2000 and Windows XP refer to each Windows manual The mark R shows major revised points The revised points can be easily searched by copying an lt R gt in the PDF file and specifying it in the Find what field To understand the overall operation of the MINICUBE2 diagnostic tool Read this manual according to the CONTENTS Note Footnote for item marked with Note in the text Caution Information requiring par
7. following folders and files will be created in the arbitrary folder MINICUBE Utilities Vxxx MINICUBE Utilities Vxxx MINICUBE Utilities Document Vxxx readme j txt readme e txt 4 Install MINICUBE Utilities Vxxx main unit as follows e f the OS is Japanese Windows execute setup exe in the MINICUBE Utilities VxxxMapaneseWDISK1 folder and install the software according to the installer instructions e f the OS is not Japanese Windows execute setup exe in the MINICUBE_Utilities_Vxxx English DISK1 folder and install the software according to the installer instructions Caution Specify C Program Files NEC Electronics Tools as an installation destination folder Remarks 1 The MINICUBE2 diagnostic tool and MINICUBE OCD Checker can be installed by installing MINICUBE Utilities Vxxx 2 GHS Green Hills Software Inc IAR IAR Systems AB 2 2 2 Startup Click the Start menu of Windows point to Programs NEC Electronics Tools Latest Version and then click MINICUBE2 Utilities Vx xx MINICUBE2 Diagnostic Tool Caution If the debugger MINICUBE OCD Checker is running terminate it before starting the MINICUBE2 diagnostic tool User s Manual U18588EJ2VOUM 9 CHAPTER 2 INSTALLATION AND STARTUP 2 3 Explanation of Each Area When the MINICUBE2 diagnostic tool is started a window with two tabs for switching two functions is displayed 1 RE MINICUBE Diagnostic Tool MINT LE or mation D3ETMPEMGB2UTL Iag
8. machine power on Power select switch Set this switch to 3 5 e Mode select switch Set this switch to M1 or M2 e Connection between MINICUBE2 and 78K0 OCD board e Whether the 78K0 OCD board is connected does not affect the operation e Terminate the debugger MINICUBE OCD Checker e Be sure to remove MINICUBE2 from the host machine power off after firmware is updated Execute the firmware download function according to the following steps 1 to 12 1 Click the PATH button EE MINIGUBE Diagnostic Tool P 1 SELF TEST File HEX File Download C Verity 0 START 2 Specify the folder where MINICUBE2 firmware MINICUBE2 Firmware Vxxx hex which was prepared in 4 3 Preparation of Download File is stored FE MINICUBE2 Diagnostic Tool Look in E D acuments ia Music A My Fictures MINICUBE2 Firmware Vxxx hex File name Files of type MIMICUBE firmware Camel User s Manual U18588EJ2VOUM 23 24 CHAPTER 4 FIRMWARE DOWNLOAD FUNCTION 3 Specify MINICUBE2 firmware MINICUBE2 Firmware Vxxx hex from the folder and then click the Open button MINICUBE2 Diagnostic Tool FN Open Look Documents da E Music Pictures MINICUBE Firmware Vxxx hex File name MINICUBE2 Firmware Files af type MINICLIBE2 firmware Cancel
9. port test OK TxD SO X2 port test OK GLK ZXI port test OK ASOK SGK part test FLMDO port test FLMD ANTP port test RESET port test RE MINICUBEZ Diagnostic Tool SELF TEST FAW MINIGLIBE2 Information 4100 1 00 7 User s Manual U18588EJ2VOUM START 15 CHAPTER 3 SELF TESTING FUNCTION 8 Click the EXIT button RE MINICUBE Diagnostic Tool SELF TEST FAW Information 4100 F w 00 START 9 Remove 2 from the host machine 3 4 Log File After self testing is performed a log file is created to hold the result The log file is overwritten each time the OK button is clicked in step 4 in 3 3 Execution of Self Testing 3 4 1 Specification of location for saving log file The location for saving the log file can be changed by clicking the log button in step 1 in 3 3 Execution of Self Testing The log file is created as MQB2UTL log in a temporary directory by default Normally the temporary directory is specified in the tmp or temp environmental variable F MINICUBE2 Diagnostic Tool SELF TEST Save EX Ea File name Save as type Lag File laq 16 User s Manual U18588EJ2VOUM CHAPTER 3 SELF TESTING FUNCTION 3 4 2 Format of log file The following shows an example of the log f
10. quality assurance program for a specific application The recommended applications of an NEC Electronics product depend on its quality grade as indicated below Customers must check the quality grade of each NEC Electronics product before using it in a particular application Standard Computers office equipment communications equipment test and measurement equipment audio and visual equipment home electronic appliances machine tools personal electronic equipment and industrial robots Special Transportation equipment automobiles trains ships etc traffic control systems anti disaster systems anti crime systems safety equipment and medical equipment not specifically designed for life support Specific Aircraft aerospace equipment submersible repeaters nuclear reactor control systems life support systems and medical equipment for life support etc The quality grade of NEC Electronics products is Standard unless otherwise expressly specified in NEC Electronics data sheets or data books etc If customers wish to use NEC Electronics products in applications not intended by NEC Electronics they must contact an NEC Electronics sales representative in advance to determine NEC Electronics willingness to support a given application Note 1 NEC Electronics as used in this statement means NEC Electronics Corporation and also includes its majority owned subsidiaries 2 NEC Electronics products means any product
11. 2127 FimwaredownloadTHBROllOlk esos o Ee o E votes bove T 1 2 5ystem COMMOULAUON iui iiie nece iota d cate M 7 CHAPTER 2 INSTALLATION AND 8 2 1 When Electronics Tool IS 8 22121 ets ee eee a eek 8 212 SISRIU S eui 8 2 2 When Tools Manufactured by Partner Companies GHS and IAR are Used 9 2 2 1 IpiStallatlori E EA A ADM A Mu e 9 9 2 9 Explanation of 10 CHAPTER 3 SELF TESTING 11 3 1 Explanation OF Each Area o e Uma abo rienced 11 3 2 CAUTIONS on Self Testing aeri cete rrr eee ei eaae ty vada 12 3 9 Execution of Self Testilig Cue OR RE 12 34 Eni eb 16 3 4 1 Specification of location for saving log mmn 16 S42 Formato log 17 3 9 Action Wheri NG Is Displayed Rte Uie dev Qe pus Dua xS EUR REVUE TuS E 17 3 5 1 X Operation when
12. 4 Confirm that the path to the folder where MINICUBE2 firmware is stored is displayed in the path indication area and the specified MINICUBE2 firmware is displayed in File 4 RE MIHICUBEZ Diagnostic Tool SELF TEST C Documer And Settings Administrator My PATH File Mame MINICUBEZ Firmware Vxxx hex HEX File Mame Firmware hex f Download Verity User s Manual U18588EJ2VOUM CHAPTER 4 FIRMWARE DOWNLOAD FUNCTION 5 Select the Download radio button Download is selected by default BE MIMICUBE Diagnostic Tool SELF TEST 5 C Documents and Settings Administrator My Docurt File MINICUBE2 Firmware Vsxx hex HEX File MIMIGUBEZ Firmware Vxxx hex Download Verity 0 START 6 Click the START button MINICUBE 2 Diagnostic Tool SELF TEST CX Documents and Settings Administrator My Docurt File Mame MINICUBE2 Firmware Vsxx hex HEX File MIMIGUBEZ Firmware Vxxx hex 6 f Download Verity 0 User s Manual U18588EJ2VOUM 25 26 CHAPTER 4 FIRMWARE DOWNLOAD FUNCTION 7 A dialog box indicating that MINICUBE2 connection was established appears and prompts the user to confirm the start of downloading Click the OK button MINICUBE Diagnostic Tool SELF TEST FAN 8 A dialog box for confirming the MINICUBE2 firmware file to be down
13. 8EJ2VOUM 31 R APPENDIX A REVISION HISTORY A 1 Major Revisions in This Edition CHAPTER 2 INSTALLATION AND STARTUP Addition of description in 2 1 1 Installation Addition of description in 2 1 2 Startup APPENDIX A REVISION HISTORY Addition of APPENDIX REVISION HISTORY 32 User s Manual U18588EJ2VOUM MEMO User s Manual U18588EJ2VOUM 33 MEMO 34 User s Manual U18588EJ2VOUM MEMO User s Manual U18588EJ2VOUM 35 For further information please contact NEC Electronics Corporation 1753 Shimonumabe Nakahara ku Kawasaki Kanagawa 211 8668 Japan Tel 044 435 5111 http www necel com America NEC Electronics America Inc 2880 Scott Blvd Santa Clara CA 95050 2554 U S A Tel 408 588 6000 800 366 9782 http www am necel com Europe NEC Electronics Europe GmbH Arcadiastrasse 10 40472 Dusseldorf Germany Tel 0211 65030 http www eu necel com Hanover Office Podbielskistrasse 166 B 30177 Hannover Tel 0 511 33 40 2 0 Munich Office Werner Eckert Strasse 9 81829 M nchen Tel 0 89 92 10 03 0 Stuttgart Office Industriestrasse 3 70565 Stuttgart Tel 0 711 99 01 0 0 United Kingdom Branch Cygnus House Sunrise Parkway Linford Wood Milton Keynes MK14 6NP U K Tel 01908 691 133 Succursale Francaise 9 rue Paul Dautier B P 52 78142 Velizy Villacoublay C dex France Tel 01 3067 5800 Sucursal en Espana Juan Esplandiu 15 28007 Madrid Spai
14. A F W is the firmware version MIMIGUBE2 4100 4 F w 1 00 D TMPEMOB2UTL User s Manual U18588EJ2VOUM 13 14 CHAPTER 3 SELF TESTING FUNCTION 4 A dialog box to confirm whether to start self testing appears Self testing is started by clicking the OK button The log file is created overwritten if the self testing was performed before 4 7H MIN 2 Diagnostic Tool Fwy 5 The upper progress bar indicates the progress status of the test currently being performed The lower progress bar indicates the status of progress for overall self testing BE Diagnostic Tool SELF TEST Fw MINICUBES Information MINIGUBE 4100 F W 51 00 5 Si test User s Manual U18588EJ2VOUM CHAPTER 3 SELF TESTING FUNCTION 6 When all of the tests are complete the final result dialog box is displayed as shown below The contents displayed in the dialog box are saved in the log file If an error occurs during self testing refer to 3 5 Action When NG Is Displayed Click the OK button SELF TEST F MINIGLIBE MINICUBES 7 is output as a final result USB power test OK 1410 Internal power test OK 5 19 LED test OK Power SW test 3V zwi SW test MODE board connect FOKO OCD board clock 20 00 MHz RxD SI port test HS port test OK RESET IM port test GLK IM
15. C Electronics products listed in this document or any other liability arising from the use of such products No license express implied or otherwise is granted under any patents copyrights or other intellectual property rights of NEC Electronics or others e Descriptions of circuits software and other related information in this document are provided for illustrative purposes in semiconductor product operation and application examples The incorporation of these circuits software and information in the design of a customer s equipment shall be done under the full responsibility of the customer NEC Electronics assumes no responsibility for any losses incurred by customers or third parties arising from the use of these circuits software and information e While NEC Electronics endeavors to enhance the quality reliability and safety of NEC Electronics products customers agree and acknowledge that the possibility of defects thereof cannot be eliminated entirely To minimize risks of damage to property or injury including death to persons arising from defects in NEC Electronics products customers must incorporate sufficient safety measures in their design such as redundancy fire containment and anti failure features e NEC Electronics products are classified into the following three quality grades Standard Special and Specific The Specific quality grade applies only to NEC Electronics products developed based on a customer designated
16. ICUBE2 4 MINICUBE2 connection of the 78K0 OCD board can be checked by self testing Users Manual U18588EJ2VOUM 7 CHAPTER 2 INSTALLATION AND STARTUP This section explains how to install and start the MINICUBE2 diagnostic tool Note that the procedure differs depending on the development tool used Refer to 2 1 When NEC Electronics Tool Is Used and 2 2 When Tools Manufactured by Partner Companies GHS and IAR are Used 2 1 When NEC Electronics Tool Is Used 2 1 1 Installation R e Select the Emulator Utilities check box when installing CubeSuite V1 00 or later the MINICUBE2 diagnostic tool will then be installed automatically e Select the MINICUBE Utilities Vx xx check box when installing ID850QB V3 20 or later the MINICUBE2 diagnostic tool will then be installed automatically e Select the MINICUBE Utilities Vx xx check box when installing ID78KO QB V2 93 later the MINICUBE2 diagnostic tool will then be installed automatically e Select the MINICUBE Utilities Vx xx check box when installing ID78KOS QB V2 82 or later the MINICUBE2 diagnostic tool will then be installed automatically e Select the MINICUBE Utilities check box when installing ID78KOR QB V3 20 or later the MINICUBE2 diagnostic tool will then be installed automatically e Select the MINICUBE Utilities Vx xx check box when installing QB Programmer V1 00 or later the MINICUBE2 diagnostic tool will then be installed automatically
17. INICUBE2 to the target system e Finish the MINICUBE2 switch setting before connecting MINICUBE2 to the host machine power e Power select switch This switch is set to 3 by default Set this switch to 3 or 5 Self testing is aborted if this switch is set to T e Mode select switch This switch is set to M2 by default Self testing is aborted if this switch is set to M1 while the 78K0 OCD board is connected e Connection between MINICUBE2 and 78K0 OCD board e Set the mode select switch to M2 if the 78K0 OCD board is connected Self testing is aborted if this switch is set to 1 e Terminate the debugger QBP and OCD Checker 3 3 Execution of Self Testing Perform self testing according to the following steps 1 to 9 1 Specify the location in which the log file will be saved by clicking the log button The self testing result will be output to this log file Refer to 3 4 Log File for descriptions on the log file RE MINICUBE Diagnostic Tool SELF TEST FW MINICUBE Information D TMPEMOB2UTL 6 12 User s Manual U18588EJ2VOUM CHAPTER 3 SELF TESTING FUNCTION 2 Click the START button RE MINICUBE2 Diagnostic Tool SELF TEST FAN Information 2 D4 TMPEMOB2UTL log 3 The MINICUBE2 connection status is checked and the hardware information is displayed the MINICUBE2 Information window In the figure below V1 00 described for MINICUBE2 4100
18. VIEW 1 4 MINICUBE2 Diagnostic Tool The MINICUBE2 diagnostic tool is software used to perform self testing of the QB MINI2 an on chip debug emulator with programming function MINICUBE2 and update MINICUBE2 firmware Use the MINICUBE2 diagnostic tool mainly for MINICUBE2 self testing Note that MINICUBE2 may not operate normally if the firmware download function is used during ordinary operation 1 1 1 Self testing function The MINICUBE2 diagnostic tool tests the following items for abnormality in MINICUBE2 e F W version indication e Voltage supplied via USB Internal e LED e Power select switch e Mode select switch Connection status of 78K0 OCD board Oscillator only when 78K0 OCD board is connected e O ports 1 1 2 Firmware download function This function is used to update the firmware program MINICUBE2 firmware embedded into the on chip flash memory of the control CPU in MINICUBE2 Caution Do not use this function for any purpose other than updating firmware otherwise MINICUBE2 may be damaged 1 2 System Configuration The following figure illustrates the system configuration that includes MINICUBE2 for using the MINICUBE2 diagnostic tool 4 3 1 lt 2 gt 1 Host machine Products with USB ports which are compatible with the debugger and QBP 2 Software Includes the MINICUBE2 diagnostic tool MINICUBE OCD Checker debugger and QBP 3 USB cable accessory of MIN
19. ersion of MINICUBE2 firmware Perform the steps in 3 3 Execution of Self Testing and confirm that OK is displayed in step 7 Confirm that the MINICUBE2 firmware version is updated in the MINICUBE2 Information window BE MIMICUBE Diagnostic Tool SELF TEST MINICUBE Information MINIGUBE 4100 ee BEBEBBBEESBBEBEBBEEBBEBEBBH mx Suir 28 User s Manual U18588EJ2VOUM CHAPTER 4 FIRMWARE DOWNLOAD FUNCTION 4 6 Failure in Firmware Download If an attempt is made to update firmware according to the descriptions in 4 4 Downloading Firmware but the operation results in any of the following consult an NEC Electronics sales representative or distributor e Firmware could not be downloaded normally Example Downloading of MINICUBE2 firmware is stopped during a step in 4 4 Downloading Firmware and no matter how many times the step is repeated from 1 the result is the same e After downloading firmware the version could not be checked normally Examples 1 3 3 Execution of Self Testing results in NG 2 Version information displayed in 3 3 Execution of Self Testing differs from the one expected e he debugger or QBP does not start normally User s Manual U18588EJ2VOUM 29 30 CHAPTER 5 VERSION INDICATION This section describes the method to check the version Click the icon on the title bar or right click the title bar the system menu is then displayed MINICUBE Diagnostic Tool Move
20. ile when the check results show OK statuses 3 5 mm dd yyyy tt mm ss Test start MINICUBE2 4100A F AW V1 00 MINICUBE2 SELF TEST OK USB power test OK 4 8V Internal power test OK 5 0V LED test OK Power SW test 3V 3 2V Mode SW test MODE2 78 05 OCD board connect These items are tested only when 78 05 OCD board clock 20 00 MHz RxD SI port OK HS port OK RESET IN port OK CLK IN port OK TxD SO X2 port OK CLK X1 port OK ASCK SCK port OK FLMDO port OK FLMD1 INTP port OK RESET OUT port OK OK the 78K0 OCD board is connected Action When NG Is Displayed Operation when NG is displayed during self testing refer to 3 3 Execution of Self Testing and relevant actions for coping with the errors such as setting errors are listed below 3 5 1 Operation when NG is displayed This message is displayed when NG is displayed by the MINICUBE2 diagnostic tool for the first time The result is not written to the log file at this stage Click the OK button F MINICUBE2 Diagnostic Tool SELF TEST F W MINICUBE Infor mation MINICUBE2 4100 4 1 00 MQB2UTL eo Is the MINICUBE2 connected to the target system User s Manual U18588EJ2VOUM 17 CHAPTER 3 SELF TESTING FUNCTION When self testing for the second or later time is displayed for items with which is detected in the re
21. is displayed 2 0 000000010 00 17 2992 NCO TON Cla On 19 CHAPTER 4 FIRMWARE DOWNLOAD 21 4 1 eive i 21 4 2 Version Check Before Downloading Firmware 22 4 3 Preparation or DOWNMIOAG os uec cO x UE KKERDUE V RN UC S NEU IM 22 4 4 DOWMIGAGING Blu gni P 23 4 5 Version Check After Downloading Firmware 28 4 6 Failure an Firmware Download esce asus 29 CHAPTER 5 VERSION 30 CHAPTER 6 31 APPENDIX REVISION 20 32 1 Major Revisions in This 32 6 User s Manual U18588EJ2VOUM CHAPTER 1 OVER
22. loaded appears Click the OK button BE MINICUBE Diagnostic Tool SELF TEST FAW MOB 2UTL File Mame Time Stamp Start Address End Address Size 009460h Cancel User s Manual U18588EJ2VOUM CHAPTER 4 FIRMWARE DOWNLOAD FUNCTION 9 The progress bar shows the status of downloading BE MIMICUBE Diagnostic Tool SELF TEST G Documents and Settings Administrator My Docu tt PATH File MINICUBEZ Firmware Vicochex HEX File Mame MIMICUBE 2 Firmware Vxxxhex t Download C Verity C Verify User s Manual U18588EJ2VOUM 27 CHAPTER 4 FIRMWARE DOWNLOAD FUNCTION 11 Click the EXIT button BE MIMICUBE 2 Diagnostic Tool SELF TEST CX Documents and SettingzEA amp dministratar Docum PATH File Mame MINICUBE2 Firmware Vxxx hex HEX File Firmware Vxxx hex f Download Verity BBEBSBBBSSBSEBBBSSBEBBBEBB START 12 Remove MINICUBE2 from the host machine Caution Be sure to remove MINICUBE2 from the host machine power off after the MINICUBE2 firmware update MINICUBE2 is run executing the MINICUBE2 diagnostic tool debugger QBP or MINICUBE OCD Checker after updating firmware MINICUBE2 firmware is not updated completely and MINICUBE2 does not operate normally 4 5 Version Check After Downloading Firmware Perform the steps in 3 3 Execution of Self Testing and check the v
23. n Tel 091 504 2787 Tyskland Filial Taby Centrum Entrance S 7th floor 18322 Taby Sweden Tel 08 638 72 00 Filiale Italiana Via Fabio Filzi 25 A 20124 Milano Italy Tel 02 667541 Branch The Netherlands Steijgerweg 6 5616 HS Eindhoven The Netherlands Tel 040 265 40 10 Asia amp Oceania NEC Electronics China Co Ltd 7th Floor Quantum Plaza No 27 ZhiChunLu Haidian District Beijing 100083 PR China Tel 010 8235 1155 http www cn necel com Shanghai Branch Room 2509 2510 Bank of China Tower 200 Yincheng Road Central Pudong New Area Shanghai P H China 200120 Tel 021 5888 5400 http www cn necel com Shenzhen Branch Unit 01 39 F Excellence Times Square Building 4068 Yi Tian Road Futian District Shenzhen P R China P C 518048 Tel 0755 8282 9800 http www cn necel com NEC Electronics Hong Kong Ltd Unit 1601 1613 16 F Tower 2 Grand Century Place 193 Prince Edward Road West Mongkok Kowloon Hong Kong Tel 2886 9318 http www hk necel com NEC Electronics Taiwan Ltd 7F No 363 Fu Shing North Road Taipei Taiwan R O C Tel 02 8175 9600 http www tw necel com NEC Electronics Singapore Pte Ltd 238A Thomson Road 12 08 Novena Square Singapore 307684 Tel 6253 8311 http www sg necel com NEC Electronics Korea Ltd 11F Samik Lavied or Bldg 720 2 Yeoksam Dong Kangnam Ku Seoul 135 080 Korea Tel 02 558 3737 http www kr
24. necel com G0706
25. ng Firmware Check the MINICUBE2 firmware version before downloading new firmware according to the following steps 1 to 3 1 Perform steps in 3 3 Execution of Self Testing and confirm that OK is displayed in step 7 Check the MINICUBE2 firmware version in the MINICUBE2 Information window In the figure below V1 00 described for MINICUBE2 4100 A F W is the firmware version BE MIMICUBE Diagnostic Tool SELF TEST MINICUBE Information MINIGUBE 4100 Fy 51 00 E L E START 2 Access the following NEC Electronics websites for checking the latest version of MINICUBE2 firmware Japanese version http www necel com micro ods jpn index html English version http www necel com micro ods eng index html See Version up service gt MINICUBE2 Software 3 Make sure that the version checked in step 1 differs from the version posted on the websites If the version checked in step 1 is the latest version do not execute this function 4 3 Preparation of Download File Download MINICUBE2 firmware MINICUBE2 Firmware Vxxx hex from the above website and save it in an arbitrary folder 22 User s Manual U18588EJ2VOUM CHAPTER 4 FIRMWARE DOWNLOAD FUNCTION 4 4 Downloading Firmware Note the following points when updating MINICUBE2 firmware using the firmware download function e Do not connect 2 to the target system e Finish the MINICUBE2 switch setting before connecting MINICUBE2 to the host
26. rt test NG lt NG If the test result includes NG as shown above the cause may be a defect in MINICUBE2 Refer to 3 2 Cautions on Self Testing and 3 5 2 Action for error and retry self testing If the same items resulted in NG even after the relevant action is implemented the cause may be defect MINICUBE2 such a case consult an NEC Electronics sales representative or distributor 3 5 2 Action for error The errors that may occur during self testing such as setting error and relevant actions for coping with the errors are listed below 1 2 Error message and action 1 Is the MINICUBE2 connected to the target system MINICUBE2 may be connected to the target system This message is displayed when an NG is displayed by the MINICUBE2 diagnostic tool for the first time If MINICUBE2 is not connected to the target system click the START button again to reexecute self testing If NG items are detected the result is displayed in the result dialog box and written to the log file Self checking is aborted Please power off the MINICUBE2 select either 3 or 5 of the power supply selection switch then restart self checking This message is displayed when the power select switch is set to T Turn off the power to MINICUBE2 and then set the power select switch to 3 or 5 User s Manual U18588EJ2VOUM 19 CHAPTER 3 SELF TESTING FUNCTION 2 2 Error message and action
27. s section describes how to update download MINICUBE2 firmware embedded into the on chip flash memory of the control CPU in MINICUBE2 and explains the window operation for verifying the downloaded firmware 4 1 Explanation of Each Area The following window is displayed by clicking the F W tab Explanation of each area is described below 1 2 3 4 5 6 1 BE MINIGUBE Diaenostic Tool SELF TEST FAW 5 File Name 6 HEX File Mame f Download Verity PATH button The file select dialog box is opened by clicking this button Specify the path to the folder in which the MINICUBE2 firmware file to be downloaded is placed The specified path is displayed in the text box Path indication The path specified by clicking the PATH button is displayed in this text box File Name drop down list MINICUBE2 firmware to be downloaded is displayed If MINICUBE2 firmware is stored where MQB2UTL exe is stored the file can be selected from the drop down list HEX File Name The file name of MINICUBE2 firmware to be downloaded is displayed Download and Verify radio buttons Whether to download or verify MINICUBE2 firmware can be selected START button When this button is clicked a confirmation dialog box appears and the downloading or verifying is started by clicking the OK button Users Manual U18588EJ2VOUM 21 CHAPTER 4 FIRMWARE DOWNLOAD FUNCTION 4 2 Version Check Before Downloadi
28. sult dialog box of 6 in 3 3 Execution of Self Testing Click the OK button UBE2 Diag MBQLITL SELF TEST F MINIGUBE MINICUBEA USB power test OK 48V Internal power test 513 LED test Power SW test zwi Mode SW test MODE FOKO OOD board connect FOKO OCD board clock 20 00 MHz Rx DSI port test HS port test RESET IM port test OF GLK IM port test Tx DSO port test OK port test NG ASOK ZSGK port test FLMDO port test NG FLMD ANTP port test NG RESET port test NG NG is output as a final result RE MINICUBE Diagnostic Tool SELF TEST FAW MIMIGLIBE2 Information MINIGUBE 4100 F w 00 be START 18 User s Manual U18588EJ2VOUM CHAPTER 3 SELF TESTING FUNCTION The result of NG is also written to the log file mm dd yyyy tt mm ss Test start 2 4100A FW MINICUBE2 SELF TEST NG lt _ USB power test OK 4 8V Internal power test OK 5 0V LED test OK Power SW test 3V 3 2V Mode SW test MODE2 78 05 OCD board connect 78 05 OCD board clock 20 00 MHz RxD SI port test OK HS port test OK RESET_IN port test OK CLK_IN port test OK TxD SO X2 port test OK CLK X1 port test NG ASCK SCK port test e FLMDO port test e FLMD1 NTP porttest NG 7 RESET OUT po
29. ticular attention Remark Supplementary information Numeric representation Binary or xxxxB Decimal XXxx Hexadecimal e Indicates an arbitrary message or item on the screen 1 indicates the name of a button command dailog box or area User s Manual U18588EJ2VOUM Terminology Related Documents The meanings of the terms used in this manual are as follows MINICUBE2 Indicates QB MINI2 an on chip debug emulator with programming function Debugger Indicates NEC Electronics integrated debugger ID850QB ID78KO0 QB ID78KOS QB or ID78KOR QB Indicates the QB Programmer GUI software used for flash programming Please use the following documents in combination with this manual The related documents listed below may include preliminary versions However preliminary versions are not marked as such O Documents Related to Development Tools User s Manuals Caution The related documents listed above are subject to change without notice Be sure to use the latest version of each document for designing etc User s Manual U18588EJ2VOUM 5 5 OVERVIEW doe pedo los 7 1 1 MINICUBEZ2 Diagnostic TOON 7 elbtesinga IIAnellob 7 1