1. Estimates of time until FULL is displayed Recording Intervals 1 second 30 seconds 1 minute 10 minutes 60 minutes P about about about about about Period 4 hours 5 days 141 days 111 days 1 year and 10 months Check This will be displayed under the following conditions The first time a battery was inserted after purchase If the battery is replaced after having been taken out for a long period If this appears all data that was stored in the Logger will have been erased CHEL Warning exceeds set limit If a measured temperature exceeds one of the already set upper and lower limits the warning LED T on the Logger will flash At the same time one of the farnin LED wi Over Limit icons will appear on the Logger LCD Ww Exceeds Upper Limit If a measured temperature exceeds the set upper limit the Logger LED will alternately flash between HI and the current temperature Exceeds Upper Limit L D If a measured temperature exceeds the set lower limit the Logger LED will alternately flash between Lo and the current temperature Starting the Warning Monitoring Function If these settings are made in an environment where one of the limits is being exceeded and recording is started the monitoring function will enter wait mode Once the current measurement falls within the set limits the monitoring function will begin to
2. Programmed Recording starts at the programmed date and time Endless Loop When the unit reaches 16 000 readings the oldest data is overwritten and recording continues n addition to communication the software is designed to help with data processing Computer Display and Printing Display downloaded data in graphs or tables and print out Create Files to save downloaded data Seving DownloadedData Convert data into Text File for exporting to spreadsheets 1 Notes about the Device used for Communication When using optical communication with Communication Port TR 50C or one of our Data Collectors please take note of the following When using these devices with our Software T amp D Recorder for Windows TR 5 7xU TR 51S will be recognized as TR 51A and TR 52S will be recognized as TR 52 please operate as such Furthermore the high speed data communication for downloading data and warning monitoring functions built into the TR 5S series cannot be used s Reading the LCD Basic LCD Display When being used in cold environments the display may become difficult to read This is not a malfunction When being used in hot environments the display may become black This is not a malfunction Battery Replacement Icon If the replacement icon appears try to replace the battery with a new one as soon as possible 1 When itis time for the battery to be repla
3. 70 to 180 C Dimensions Diameter 2mm Cable length 0 6m Thermal Time Constant in the air Approx 15 sec in agitated water Approx 2 sec Shielding Teflon resin FEP Waterproof Capacity Only the sensor tip is waterproof the rest is immersion proof IPX7 Notices about this User s Manual All rights of this User s Manual belong to T amp D Corporation It is prohibited to use duplicate and or arrange a part or whole of this User s Manual without the permission of T amp D Corporation Please follow the safety precautions carefully We cannot guarantee nor are we responsible for safety if this product is used in any manner other than was intended T amp D Corporation accepts no responsibility for any malfunction of and or trouble with this product or with your computer that is caused by the improper handling of this product and will deem such trouble or malfunction as falling outside the conditions for free repair of the attached warranty T amp D Corporation accepts no responsibility for any result or effects from using this User s Manual Figures and illustrations in this manual may be slightly simplified and may differ from the actual product We sincerely hope that the contents of this manual are true and complete If you find any information to have been omitted or if the information within is confusing or mistaken please contact your retailer or T amp D Corporation The war
4. operate Removing a Warning Under the following conditions the warning display will be removed When a Recording Start session is begun from the software When Clear Warning is carried out from the software only via TR 50U When recorded data is downloaded and is successfully completed When the battery is removed or battery power has been lost and the CHEC icon appears Measurement Range Exceeded for TR 52S only ma m The current temperature display will blink when the 5 5 rm S temperature goes below 60 C or goes above I ALIS 155C Sensor Unconnected for TR 52S only Displayed when a sensor has not been connected or the wire has been broken Measurement and recording will continue and battery power consumed
5. Thermo Recorder TR 51S TR 52S Warranty Customer s name Address Phone No Dealer s name Address Phone No Guarantee period 12 months from date of purchase Date of purchase Statement of Limited Warranty This product is warranted to be free from defects in materials and workmanship for a period of one 1 year following the date of purchase Should the product fail to operate per specification in normal use during this period T amp D will repair the unit or provide a replacement free of charge T amp D will not accept returns for any reason other than defects during the warranty period and will not accept any product that has been misused dropped abused or inappropriately used or mistreated at any time N This warranty is strictly limited to repair or replacement in kind for defective product T amp D makes no other warranty either express or implied and will not accept liability beyond the remedies stated herein Specifically T amp D will not accept liability for direct indirect special consequential or incidental damages arising from the use of this product 9 j Customers wishing to submit a defective product for repair or replacement during the warranty period should first contact the dealer from whom it was originally purchased After receiving a return authorization the defective product should then be packaged along with a description of the difficulties being experienced proof of p
6. al Sensor Type Temperature Sensor for TR 52S IP67 Immersion proof IP64 Splash resistant eN 600mm LCD Display LCD Display E i Waterproof 7 6 Thermistor Teflon Resin FEP Shielded Connecting the Sensor Connect the sensor adapter to the sensor jack on the logger Make sure that the plug is completely inserted until you hear a click sound Port About Optional Sensors Please see our Web Site for details about optional sensors available for the TR 52S Sensor Jack TR 52S is not water resistant unless the sensor has been connected Outline We offer two types to fit your needs the TR 51S with internal sensor offers improved water resistance and the TR 52S with external sensor brings quicker response to changes in temperature Both are ideal for measuring and recording temperature in normal outdoor conditions as well as harsher frozen environments or frozen storage The compact design makes it no problem to place almost anywhere For downloading data to computer for saving and processing use either one of our Communication Ports TR 50U or TR 50C or our handy Data Collectors TR 57U or RTR 57U By using with our newly released Communication Port TR 50U it is possible to take advantage of the highest communication speeds for downloading data up to 8 times faster than our previous models We have removed all switches from the main unit to assure nothing gets accidental
7. alled and recording does not immediately start the display is jumbled or nothing appears the circuit board may have been touched while installing the battery Please remove the battery and try installing again When inserting a battery make sure no water or foreign objects get inside the case Lithium batteries CR2 sold in stores may also be used but if you are using in an environment below 20 C above 60 C or in a situation such as transportation where continued vibration is likely to occur we suggest the purchase and use of the optional lithium battery ER3V M Make sure that and are in the correct direction If they are not correct it may cause damage After inserting the battery it may occur that nothing appears in the display for about 10 seconds this is not a malfunction Communication with your Computer In order to make recording settings in the Logger and download data from the Logger to your computer it is necessary to carry out communication via optical communication using one of T amp D s Communication Ports or Data Collectors sold separately For details about how to make recording settings download data and other operations please see the User s Manual that comes with the Communication Port or Data Collector Set up Procedure 1 Connect the Communication Port or Data Collector to your computer using the provided communication cable Communication cable Communication Port or Data Colle
8. and 60 minutes LCD Display Items Temperature measured rec cording conditions battery life warning memory FULL sensor unconnected over measurement range temperature unit F 1 C and Upper Lower limit over Power 1 Lithium battery ER3V M x1 Lithium battery CR2 also Okay Battery Life 2 Maximum 4 years Waterproof Capacity 1P67 Immersion proof 1P64 Splash resistant External Dimensions H62mm x W47mm x D19mm Excluding protrusions Weight Approx 54g including battery Approx 55g including battery Standard Sensor Built in TR 5106 Teflon resin sensor Unit Temp Resistance 40 to 80 C Accessories Included Lithium Battery ERSV M x 1 Tube x 1 Strap x 1 User s Manual Warranty x 1 1 The lithium battery ER3V M is not sold in stores It can be purchased through our distributors as Optional Battery Set TR 10P2 Normal lithium batteries sold in stores CR2 can be used but the operating range is reduced to 20 C to 60 C If you will be using the logger in an environment where temperatures may be lower than 20 or higher than 60 C we strongly suggest purchasing and using the Optional Battery Set TR 10P2 2 Battery life depends upon the measuring environment recording interval and quality of the battery being used Specifications for TR 5106 Temperature Sensors for TR 52S Sensor Heat Durability
9. ced the E49 icon will appear 2 After removing the battery wait for about three seconds until the bAtt appears Once this appears please change the battery as quickly as possible LAEE If the battery is replaced before bAtt appears even after replacing the GM icon may remain After a battery is installed if bAtt remains on display for more than one minute please check to make sure that the battery has been properly installed If after checking the icon continues to appear please try to carry out some optical communication If optical communication is psossible the icon will disappear within an hour Downloading of data cannot occur while the battery is removed Recorded data will be saved and recording will continue 3 If the battery is further left unchanged the display will automatically shut off If at this time a new battery is placed in the unit CHEC will appear on the display after which recording will begin again using the previously set recording conditions Note however that all previously recorded data will have been lost Estimating Battery Life These estimates are based on using a new battery Battery Life will be greatly shortened if communication is carried out quite often and or if the recording interval is set for 10 seconds or less Communication frequency 4 times month Recording Interval 1 second 2eeconds 5 30s
10. ctor 2 Place the TR 51S 52S Data Logger on top of the Port or Collector as shown in the figure making sure that the optical communication spots are aligned properly Data Collector 1 Compatible Devices RTR 57U RTR 57C TR 51S 52S Communication cable Communication Port Compatible Devices TR 50U TR 50C 1 TR 51S 52S Communication cable A Communication errors may occur in environments where temperatures are very high or very low Communication may not be possible if battery power is extremely low Recording Condition Settings which can be made via Optical Communication The following settings can be made via computer communication Initial Setting Values Recording Interval 10 minutes Recording Mode Endless loop Recording Intervals Select from 1 2 5 10 15 20 30 seconds 1 2 5 10 15 20 30 60 minutes Recording Methods Immediate Recording starts immediately upon battery One time installation When the unit reaches 16 000 readings the LCD alternately displays the current reading and FULL and recording stops Programmed Recording starts at the programmed date and time One time When the unit reaches 16 000 readings the LCD alternately displays the current reading and FULL and recording stops Immediate Endless Loop Recording starts immediately upon battery installation When the unit reaches 16 000 readings the oldest data is overwritten and recording continues
11. econds 1 minute or more about Battery Life about 2 years about 3 years about 4 years id 16 months gt an The B icon will appear based upon the calculation of battery use It may appear sooner than noted above If the unit is left with the warning LED blinking battery life will be halved Notes about Changing the Battery Replace with a new battery following directions as in Installing the Battery Recording will continue using the previously set recording settings or will restart using those settings If plus and minus are mistaken or if the battery terminals and are shorted the recorded data that is stored in the logger will be lost Before replacing a battery please make sure to download any necessary data and proceed with changing the battery For details see the User s Manual that came with the software Please store the ER3V M in a place that is 20 C or less Recording Status REA LIT UP displayed during recording or when FULL of data BLINKING displayed when waiting for a programmed recording to start Battery Replacement Icon displayed when time to change the battery Measurement Reading and Message Display Unit of Measurement displays unit of measurement Other Icons Full Memory When using the One time Recording Method the pa ID 0 REC icon appears when the number of recorded LL readings reaches 16 000 and the unit stops recording
12. ese limits are designed to provide reasonable protection against harmful interference ina residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help WARNING This equipment has been verified to comply with the limits for a Class A personal digital device pursuant to Subpart B of Part 15 of FCC Rules Only peripherals computer input output devices terminals printers etc certified or verified to comply with the Class A or B limits may be attached to this equipment Operation with non certified or non verified personal computer and or peripherals is likely to result in interference to radio and TV reception The connection of a non shielded equipment interface cable t
13. ly pushed during use thus assuring you of no mistakes no tampering and no loss of data Up to 16 000 measurement readings can be recorded at a recording interval of 60 minutes that would equal about 666 days or about 2 years of non stop consecutive recording The latest version of our software can be downloaded free of charge from our Web Site Please visit us at http www tandd com for more information The units can be operated with T amp D Recorder for Windows TR 5 7xU version 1 50E or later included with our Communication Ports and Handy Data Collectors Note Packing ar pt Battery Inserted into Installing the Battery When a battery is installed temperature measurement will start at the default settings 1 Remove screws and open the case Make sure to use the proper type and size screwdriver A Phillips head 1 is best 2 Insert the attached battery into the tube and mount the tube in the direction shown in the figure Tube is not necessary in the case of using CR2 aq 3 Confirm that the rubber packing does not have dust io or defects Close the case and screw on the cover or Dust or defects on the packing can adversely affect the waterproof characteristics Make sure the cover is closed in the correct direction Please do not tighten the screw too tightly appropriate torque 20N cm 30N cm 2Kgf cm 3Kgf cm Tube If a new battery has been inst
14. o this equipment will invalidate the FCC Certification of this device and may cause interference levels which exceed the limits established by the FCC for this equipment You are cautioned that changes or modi cations not expressly approved by party responsible for compliance could void your authority to operate the equipment Thermo Recorder TR 51 S 52S User s Manual AND Thank you for purchasing this product Carefully read and fully understand these instructions before using this unit CE T amp D coRPoRATION 5652 169 Sasaga Matsumoto City NAGANO 399 0033 JAPAN Tel 81 263 27 2131 Fax 81 263 26 4281 Homepage http www tandd com E mail overseas tandd co jp Copyright 2007 T amp D Corporation All rights reserved Product Specifications 2007 09 16004514030 1st printing This is printed using recycled paper TR 51S TR 52S Measurement Item Temperature Temperature Measurement Channels 1Ch Internal Sensor Type 1Ch External Sensor type Measurement Range 40 to 80 C 60 to 155 C Typ 0 3 C 20 to 80C Typ 0 5 C 40 to 20C Measurement Accuracy Typ 05 C 80 to 110 C Typ 1 0 C 60 to 40C 110 to 155 C Measurement Display Resolution 01 Recording Capacity 16000 data Recording Start Method Immediate Programmed Recording Mode Endless One time Recording Interval Select from 1 2 5 10 15 20 and 30 seconds or from1 2 5 10 15 20 30
15. ollowing cases The case was closed with dust hair etc on the rubber packing or in the groove for the packing The rubber packing becomes damaged in this case please purchase the optional maintenance set The unit suffered from significant temperature change while wet Especially in the case that the temperature changes from high to low We are not responsible for any malfunction or trouble caused by the use of our product or by any problem caused by the malfunction of our unit Please be fully aware of this before using our product This product has been designed for private or industrial use only It is not for use in situations where strict safety precautions are necessary such as in connection with medical equipment whether directly or indirectly Do not use or store the unit in places such as listed below It may cause electrocution fire or damage to the unit or to your computer Do not drop or expose the unit to strong impact Areas exposed to direct sunlight Do not put your fingers or foreign matter into the sensor connection Areas exposed in water or high pressure water flow Areas exposed to organic solvents and corrosive gas Areas exposed to strong magnetic fields Areas exposed to static electricity Areas exposed to fire or overheating Areas exposed to excessive dust or smoke D Do not put your fingers or foreign matter into the communication port When using the included Sens
16. or TR 5106 please take note of the following Do no bend the sensor tip section or expose it to a strong impact This may cause trouble or break the wire The sensor and the cable are shielded by Teflon If the shield has a defect or tear the waterproof capacity is lost as the shield is very thin Inspect it before operation Insert the sensor tip to at least Scm or more to obtain on accurate temperature measurement Only use the sensor within the sensor heat durability range The units can be operated with T amp D Recorder for Windows TR 5 7xU version 1 50E or later The latest version of T amp D Recorder for Windows TR 5 7xU can be downloaded free of charge from our Web Site gt Battery life depends on the measurement environment communication frequency recording interval and battery quality gt R e OBR D e The TR 52S only becomes water resistant IP64 splash resistant if the temperature Contact with oil may cause cracks to appear in the casing of the unit sensor has been connected Ifthe unit is being used in an environment where there is a possibility of Without the sensor connected the connector part of neither the main unit nor the temperature sensor oil spraying or splashing T amp D strongly advises that the unit be placed in a is water resistant make sure not to get wet Polyethylene bag before using Part Names TR 51S TR 52S TR 5106 Internal Sensor Type Extern
17. ranty that is included in this User s Manual cannot be reissued so please keep it in a safe place This manual has been written using C as the standard unit of temperature Safety Precautions and Instructions Piease carefully observe the following safety measures when using our product To prevent any loss or damage to our customers other people and or property and to ensure the proper use of our products we ask that before using our product you carefully read understand and follow the safety rules and precautions for our products as outlined below Z DANGER Do not take apart repair or modify the main unit It may cause fire electrocution or damage Ask the shop where you purchased the products or T amp D Q If water or a foreign object enters the case immediately cease using it Corporation to carry out any repairs Store all batteries sensors and Thermo Recorder units out of the reach of children If any smoke or strange smells are emitted from the unit immediately cease using it iis danara alow Ei Continued use may cause fire electrocution or damage Do not use any batteries other than those that are recommended It may cause fire or damage Please be careful when using in overly hot or cold environments touching the units may cause burns or frostbite gt Oo gt Z CAUTION Pay attention as water leakage or foreign objects entering into the unit case is possible in the f
18. urchase and all included accessories and materials and return it to the dealer In the event of difficulty contacting the original dealer customers should contact the nearest authorized T amp D sales representative A list of these can be found on the company s website www tandd com or it can be obtained by contacting TandD US directly This limited warranty statement gives the customer specific legal rights The customer may also have other rights which vary from state to state in the United States from province to province in Ganada and from country to country elsewhere in the world To the extent this limited warranty statement is inconsistent with local law this statement shall be deemed modified to be consistent with such local law Ga For turther information relating to product repair or replacement or for other service questions after the termination of the warranty period customers should contact their local authorized T amp D sales representative T amp D conponanon FCC Compliance Statement for American Users This device complies with Part 15 of the FCC Rules Operation is subject to following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation NOTE This equipment has been tested and found to comply with the limits for a Class A Digital Device pursuant to Part 15 of the FCC Rules Th

Download Pdf Manuals

image

Related Search

Related Contents

8174 UI-15介面前蓝牙带内置GPS带数字TV(ISDB-T)带IP  消費税率改定に伴う価格表示変更について  Athlétisme  取扱説明書 (4.61 MB/PDF)  取扱説明書 - 三菱電機    User Manual of the “Full duplex” Bluetooth Audio  

Copyright © All rights reserved.
Failed to retrieve file