1. orio 10 5387 1 pke IP Link Device Interface Revision 11 8 201 1 Communication Sheet This document provides additional assistance with wiring your Extron IP Link enabled product to your device Different components may require a different wiring scheme than those listed below For complete operating instructions refer to the user s manual for the specific Extron IP Link enabled product or the controlled device manufacturer supplied documentation Device Specifications Device Type Display Manufacturer Orion Firmware Version N A Model s 46RNCS Version History Driver IP Link GC Version Date Compiler Version Notes 1 10 14 2011 1 4 0 3 2 0 Initial version Driver Notes By default ID is set to 1 Page 1 of 4 orio 10 5387 1 pke IP Link Device Interface Revision 11 8 201 1 Communication Sheet Control Commands amp States Broadcast 1 99 Video 1 Video 2 S Video RGB DVI HDMI Component Camera Media Menu Navigation Status Available N A Page 2 of 4 orio 10 5387 1 pke IP Link Device Interface Revision 11 8 201 1 Communication Sheet MLC62 Supported Commands Executive Mode On Off Freeze On Off Input Video 1 Video 2 RGB DVI Component Camera Menu Navigation This will only work with ID 1 Page 3 of 4 IP Link Device Interface orio_10_5387_1 pke 3 Communication Sheet Revision 11 8 201 1 Cable and Adapter Requirements F F RS232 Nul 2. l Serial Cable Notes for the Device Serial communication Port Type RS 232 Parity None Baud Rate 9600 Stop Bits 1 Data Bits 8 Flow Control None Pin Assignments Diagram COM 1 5 o E o EET Signal Pin Main Cable Pin Signal 2 3 5 i RxD 2 RxD RS232 DB9 Male ax TxD 3 TxD RS232 DB9 Male IP Link Device n GND 5 GND Display Interface Note Captive screw connector may also be used as a serial connection General Notes Page 4 of 4