1. 6 Rotameter AGL 14 According to ISO norm their air entrance in the cluster must be between 4 12 L min that basically should enter by the cluster hole The rotemeter allows us measuren this figure ensuring the correct milk flux towards the milking tube and avoiding long milking times 05 03 0001 7 Flowmeter AFM 3000 ISO Kit This package include AFM 3000 Flowmeter 3 conection adapters 50 40 30 Flowmeter by pass 2000 L Digital vacuum meter Protection suitcase Rotameter optional 10 02 0018 EDITION precisi n S L Milking Machine Control Products Catalogue EDITION precision S L Milking Machine Control Products Catalogue Modern tools 8 PT V Pulsator tester The Medition pulsotester PTV is remarkable for its multifuntionality No longuer are differents instruments required for the monitoring of a milking parlour The PTV combines a vacuum gauge a pulsator tester and an airflowmeter in a single instrument besides performing dynamic measurements Moreover it has installed ISO and UNE protocol The pulsatortester PT V will be delivered ina Standar box including the mentioned accesories lt 01 01 0003 e Memory capacity 0 1 Mb 50 measurements e Backlight display e Main adapter 100 230V 50 60Hz e Car adapter 12V e Nylon Protection bag e Bag with 20 filters e Reportgenerator and user manual on CD ROM e Cable zero modem 01 01 0004 Increase
2. Milking Machine Control Products Catalogue EDITION precisi n E C Garcia Torcal 22 50016 Zaragoza Spain Tel 34 686 943133 Fax 34 976 138337 E mail perezportero pulsografo net Web www pulsografo net EDITION precisi n S L i Milking Machine Control Index and presentation Products Catalogue Index TOO mc a GE Tradicional tools Modern tools Suitcases Consumables Collapse Measurement tools Report and graphics of PT V Repairs and calibration services June 2007 Dear customer We are pleased sending you our products and service catalogue As you probably knows Medition is the only company dedicated full time to products and services of milking machine measurement Pulsatortesters airflowmeters and vacuumeters are our day a day Tell us please your needs and we will try to fullfil quickly and with effectiveness Our repairs and calibration service knows perfectly all these tools and we will give solution to the breakdown or to the most frequent demands on calibration and certification Thus we hope this catalogue helps you and any question don t hesitate contact us we will deal with pleasure Best regards Javier P rez Portero Medition Precision S L Manager EDITION precisi n S L Milking Machine Control Products Catalogue Tradicional tools 1 PT IV Pulsatortester The extremely successful forerunner of the PT V is a measurement instrument that h
3. pump and a metacrilate cover that together with the digital vacuumeter DVPM allows you make all these measurements Here we insert informative draws to know how and where measure these two parameters 1 Milking unit in normal situation 2 Overpressure Measurement manual vacuum pump joint to vacuum meter in short pulsation tube Cow sheep goat in milking position We work the manual pump as far as milk flows At this moment we write vacuum Kpa of these liner 3 Collapse measurement manual vacuum pump joint to vacuum meter in short milk tube or in liner We measure in the office or in the farm not with animal metacrilate in the mouth of the liner We work the R EL pump and see in which Kpa point the liner SELLE walls touch them DVPM 01 Report and graphics of PT V PULSATOR MEASUREMENT LUCAA 09 42 12 22 2006 PtV Test Report for Farm index A012 06 15 2006 09 56 FARM LUCAA TESTER AB CURVE MEASUREMENT LABEL Vacuum value in kPa SENSOR VACUUM PRESSURE A B C D A B NT 1 SENSOR 50 6 0 8 25 339 45 349 594 5 6 54 6 4 6 35 3 60 1 INT 2 SENSOR 49 9 0 8 55 539 45 349 594 5 6 54 6 4 6 35 3 60 1 kPa INT1 INT MADE TO MEASURE PROTOCOL PT V have installed several protocols ISO NMC UNE Optionally we can prepare for you your own protocol inside PT V measurement lines Here it is an example 16 i
4. 0 J 25 A kPa NT 1 INT 2 Repairs And Calibration Services For all these tools with have technical service that will asist you in possible necessary repairs and also in calibrations and certifications for your tools For that you must phone or e mail us We will tell you where to send your tool well package In few days it will be returned to you repaired and with calibration certificate alie EDITION precisi n S L al habs ed haa bal Lat et ah alata al halal a al a a C Garcia Torcal 22 50016 Zaragoza Spain Tel Javier P rez Comercial 34 686 943133 Tel Miguel Geijo Technical 34 649 837936 Fax 34 976 138337 E Mail perezportero pulsografo net E Mail geijogarcia pulsografo net Web www pulsografo net
5. as unquestionably proved itself in practice A built in miniprinter allows direct display of among other results the pulsation curve and the vacuum fluctuations within the milking system PT IV standard program 01 01 0001 2 AFM 3000 Flowmeter Airflowmeter with two scales with high ressistance precision and field experience Range 0 3000 L min with by pass it reachs 5000 7000 L AFM 3000 Flowmeter lt 10 02 0000 3 DVPM 01 Digital Vacuum meter This handly digital vacuum meter measures both under and over pressures The DVPM 01 is a low cost and user friendly way of rapidly measuring vacuum levels A built in battery allows you to perform measurements with the DVPM 01 virtually anywhere Its DVPM 01 moisture proof design high level of accuracy and compact size make the DVPM 01 an DIGITAL VACUUM PRESSURE METER indispensable and reliable measurement VACUUM RANGE 0 100 kPa PRESSURE RANGE 0 100 kPa tool n 5 Lemon DVPM 01 Digital Vacuum meter lt 01 01 0026 Tradicional tools 4 Airflowmeter By pass 2000 l min By pass to join to the mouth of flowmeter Their holes allow 2000 L m of air entrance Thus the all open flowmeter reach 5000 L min 01 01 0006 5 Conection adapters for flowmeter With different inner diameters 46 38 31 5 mm to connect your flowmeter to the milking machine 46 46 mm lt 01 01 0007 46 38 mm lt 01 01 0008 46 31 5 mm lt 01 01 0009
6. d during insertion of the needle can be removed because they disturb the measurement Besides there is a fluid trap to avoid the milk arrives to the PT 01 01 0023 EDITION precisi n S L Milking Machine Control Products Catalogue Suitcases 13 Small suitcase To carry the PT V carefully we can offer two different protection cases These protection cases carries the airflow meter external transducers and accessories 01 01 0021 14 Big suitcase To carry the PT V carefully we can offer two different protection cases These protection cases carries the airflow meter external transducers accessories and printer 01 01 0022 15 Flowmeter suitcase To carry the AFM 3000 the vacuum meter and another accesories carefully we offer protection suitcases 1t 01 02 0029 EDITION precisi n S L Milking Machine Control Consumables Products Catalogue PT IV Inkribbon 3t 01 02 0029 PT IV Paper roll 01 02 0029 Filtres 01 02 0029 PT IV and V batteries E 4 01 02 0029 Liner Top PT main adapters 01 02 0029 01 02 0029 Caradapter DVPM Protection 4 01 02 0029 4 01 02 0029 EDITION precision S L Milking Machine Control Products Catalogue Collapse Measurement tools Due to the growing interest around the overpressure and collapse measurement we put to your disposal one manual vacuum
7. d price for bigger memory capacity 0 5 Mb 290 pulsator measurement without download to PC 9 AFM V Flowmeter 200 3000 l min This is an airflowmeter that reads in the PTV screen because both are conected by jeans of a cable Easy to use it allows measure vacuum pump flor reserves and ISO and another protocols Range uo to 3000 L and with 1 or 2 by pass up to 5000 y 7000 L min Not the noisy disturbances of another flowmeters X 01 01 0005 EDITION precisi n S L Milking Machine Control Modern tools Products Catalogue 10 Stainless steel external transducer The basic pulsatortester model comes with two vacuum entrantes If we want 4 entrances we should add two of these transducers Ideal for dynamic measurements and ISO protocol rubber tube coming from pump regulator and end unit tus it can be done everything without leaving the end unit 01 01 0010 11 Printer Several comercial printer can be connected to the PT V Alternativelly we offer a total solution by mean of this portable printer that can be used to print in the farm or then form the memory in the office DPU 414 Printer include main adapter serial cable and rechargeable batery C 01 01 0018 12 NOP Needle For measuring during milking time with the PT V or V measure vacuum in the liner punching this a NOP needle is available which is fitted with a sliding mechanism so that the rubber particles create
8. ndex A003 09 05 2007 13 40 FARM SMITH TESTER A ISO 6690 MEASUREMENT LABEL Vacuum value in kPa INSTALATION VACUUM METER kPa 42 0 TECHNICAL VACUUM METER kPa 41 7 FINAL LINE VACUUM kPa 41 8 VACUUM SENSITIVITY kPa R P M 899 CORRECTION FACTOR 1 00 PUMP CAP 50kPa WITHOUT CORR L M 2093 PUMP CAPACITY AT 50 kPa L M 2093 PUMP CAPACITY AT WORKING VAC L M 2470 VACUUM LINE L M 2419 MILK LINE L M 2295 METERS L M 2295 CLUSTERS SHUT OFF L M 2218 MILKING UNITS L M 2145 PULSATORS L M 1988 MANUAL RESERVE L M 2195 EFFECTIVE RESERVE L M 2195 aire line leakeages L M 51 milk line leakeages L M 124 meters leakeages L M 0 cluster shut off leakeages L M 77 milking units leakeages L M 13 pulsator leakeages L M 157 regulator leakeages L M 0 10 C D 394 39 9 394 39 9 another countries oo IMP EDITIO precisi n S L Milking Machine Control Products Catalogue PULSI 988 60 7 Lud 988 60 7 EDITION precision S L Milking Machine Control Products Catalogue Report and graphics of PT V CONSTANT VACUUM IN LINER index A015 06 23 2006 12 54 FARM LUCAA TESTER AB CONSTANT MEASUREMENT LABEL Vacuum value in kPa SENSOR TYPE WORKVAC AVG VAC MAX VAC MIN VAC VAC VAC VAC DROP INT 1 SENSOR MEDICION TIPO 1E49 0 2243 31 9 0 1 6 6 25 2 23 7 INT 2 SENSOR MEDICION TIPO LE49 0 0 0 0 1 0 0 0 1 0 0 49 0 35 3