1. User Manual Antari HZ 400 Hazer Congratulations on the purchase of your new ANTARI HAZER Introduction Thank you for choosing an ANTARI Hazer You now own a rugged and powerful state of the art machine Prior to use we suggest that you carefully read all of the instructions By following the suggestions found in this user manual you can look forward to the reliable and satisfactory performance of your ANTARI Hazer for years to come Please follow these operation and safety instructions to ensure a long and safe life for your hazer Cautions Donot overfill your ANTARI hazer Overfilling will cause the unit to clog Danger of electric shock Keep this device dry For inside use only Not designed for outside use For the 110V models use 3 prong grounded electrical outlet only Prior to use take care to determine that the unit is installed at the rated voltage Always unplug your ANTARI Hazer before filling its tank Keep hazer upright Turn off or unplug when not in use This machine is not water or splash proof If moisture water or hazer liquid gets inside the housing immediately unplug the unit and contact a service technician or your ANTARI dealer before using it again No user serviceable parts inside Refer to your ANTARI dealer or other qualified service personnel For adult use only Hazer must be installed out of the reach of children Never leave the unit running unattended Never aim the o
2. ace and remove hazer liquid tank cap Note the maximum fluid level mark located on the rear of the hazer Pour hazer liquid into the liquid tank being careful not to exceed the maximum fluid level DO NOT OVERFILL Use only ANTARI Hazer Liquid or other dealer recommended high quality hazer fluid Any other types of fluid can damage the unit When liquid level reaches the fill line place cap back on liquid tank Your hazer may be operated with or without a remote controller If you will be controlling your unit remotely firmly attach the remote control cable to the proper input Operation Plug power cord into a grounded electrical outlet To operate without remote control simply turn hazer on Haze emission will begin automatically To operate via remote control press the appropriate button on the remote to begin haze emission For further information on operating your ANTARI Hazer see the section titled Remote Control Operation If your model includes a mounting bracket designed for overhead installation it may be installed at floor level or suspended overhead If the unit is to be mounted using the bracket avoid suspending the unit such that haze is emitted directly toward any one s face Whatever installation method you choose do not allow the unit to have more than a 15 degree angle of inclination Important Always monitor tank fluid level during operation Running a hazer with no fluid can permanent
3. ly damage the unit If you experience low output mechanical noise or no output at all unplug immediately Check fluid level the external fuse remote connection and power from the wall If all of the above appears to be O K plug the unit in again If hazer does not function after 30 seconds discontinue operation or permanent damage to the unit may result Return the machine to your ANTARI dealer Always drain tank before mailing or transporting this unit Remote Control Operation HC 1 10 meter wired multi function remote controller with stereo plug for the ANTARI Hazer HZ 400 Its two knobs allow the operator to program hazer functions by adjusting haze emission duration and interval Press the yellow TIMERS button to activate the timer function Adjust the interval between each haze emission within the range of 10 seconds to 5 minutes by means of the INTERVAL control knob Adjust the duration of each haze emission within the range of 1 to 10 seconds by means of the DURATION control knob When pressed the green MANUAL button activates the hazer overriding all other function controls Press the red CONTINUOUS button for continuous output HCR 1 Wireless remote controller with stereo plug for the ANTARI Hazer HZ 400 Attach the receiver s magnetic base to the hazer Plug the receiver s cable into the hazer s remote control input Using the sending unit your ANTARI Hazer can be operated from a distance of up to 50 meter
4. s Start haze emission by pressing the small button on the sending unit Stop haze emission by pressing the large button Multiple ANTARI Hazers may be controlled using only one sending unit DMX Operation The HZ 400 has onboard DMX control Currently it uses 1 channel to control output operation The DMX channel is set on the back panel of the HZ 400 by setting the dip switches to the desired channel If Channel A has a value from 0 to 5 the unit is OFF Between the values 6 to 249 the HZ 400 produces haze Hazer Liquid Do not allow the hazer liquid to become contaminated Always replace the caps on the hazer liquid container and the hazer s liquid tank immediately after filling ANTARI Hazer Liquid comes in two varieties ANTARI HZL 1 is a high performance low residue oil based hazer liquid that has been designed specifically for HZ 100 and HZ 400 ANTARI HZL 1W is a non residual water based hazer liquid suitable for the HZ 100 and HZ 400 Important Never mix oil based and water based hazer liquids Before switching the kind of hazer liquid in use completely drain the hazer s tank to avoid mixing Save these instructions
5. utput at open flames Danger of explosion Never add flammable liquids of any kind oil gas perfume to the hazer liquid Pay attention to all warning labels and instructions printed on the exterior of your ANTARI Hazer Use only the high quality hazer liquid that your dealer recommends Always make sure there is sufficient liquid in the hazer liquid tank Operating this unit without liquid may cause permanent damage to the machine If your ANTARI Hazer fails to work properly discontinue use immediately Drain all hazer liquid from the tank pack the unit securely preferably in the original packing material and return it to your ANTARI dealer for service Never drink hazer liquid If it is ingested call a doctor immediately If hazer liquid comes in contact with skin or eyes rinse thoroughly with water Unpacking amp Inspection Open the shipping carton and verify that all equipment necessary to operate the system has arrived intact If any equipment is missing contact your ANTARI dealer immediately Before beginning initial setup of your ANTARI Hazer make sure that there is no evident damage caused by transportation In the event that the unit s housing or cable is damaged do not plug it in and do not attempt to use it until after contacting your ANTARI dealer for assistance Setup Remove all packing materials from shipping box Check that all foam and plastic padding is removed Place hazer on a flat surf