Home

Logic Net Installation

image

Contents

1. 10 TROUBLE SHOOTING kn eva l au a n aeu pae 11 SOFTWARE DEVELOPMENT 4 nia nkanun audae 13 SPECIFICATIONS 14 FEATURES The LS6000 Logic Net eStation is the Ethernet version of Logic Net the industry s leading kitchen video display system solution It has succeeded the advantages of Logic Net and yet facilitates network implementation with the most popular Ethernet connections Highly Reliable No complex PC work stations Low power operation low internal temperature rise Simple hardware and no disk drive no moving parts Reliable latched interface connections Rugged die cast housing Standard Ethernet network connection Stable operation no computer crashes viruses and lockups Tamper proof no on off and option switches no adjustable devices Low Cost PC workstations NOT required Network software NOT required Network cards NOT required expansion hardware NOT required Simplified installation and setup Advanced Operations 256 text foreground and background color Icon display continuously showing connection status of Ethernet and keyboard Touch screen support Status line display for showing status messages help items alerts or on screen touch function keys with touch screen support enabled Beep tone pitch controllable in command such that each station can beep wit
2. Power Status LED The power status LED is located on the front of the LS6000 A light indicates that power is ON When communicating with the host server the LED will blink Speaker Beeper The beeper function is controlled by host software applications The frequency of the beeper tone can be adjusted from the LS6000 Setup screen Keyboard An RJ 11 to PS2 adapter will connect the LS6000 to a standard PC keyboard Other keyboard wedge interface input devices such as Bumpbars Bar Code Scanners or Magnetic Stripe Readers can also be connected to the LS6000 The Logic Controls KB1700 Bumpbars are specially designed for use in the kitchen Refer to the KB1700 manual for more information on the bumpbar Displays Monochrome or Color VGA LS6000 supports any standard color or monochrome VGA CRT or LCD display using a standard 15 pin DSUB VGA connector RS 232 Devices The two auxiliary RS 232 ports on the LS6000 supports connections to serial printers touch screens barcode scanners and other serial interface I O devices The first serial port is a standard 9 pin DSUB connector The second port is an RJ45 connector with EIA 561 pin out Power Requirements The power supply for LS6000 is same as the one used for LM3000 and LS3000 The power supply is designed for single phase sinusoidal ac operation and accepts a wide input range 3 that does not require intervention to change between low and high voltage AC Operation at any volta
3. IP address group Check host server application software IP address and socket number setup Restart software if necessary and test again Reboot the host server and test again Replace Ethernet hub or switch and test again 11 LS6000 does not respond to keyboard commands 1 Check the keyboard cable connections at both the keyboard and the LS6000 Unplug the cable and re insert fully Check whether it snaps in correctly Reset the LS6000 and hit Del or Down Arrow key at boot up screen to enter setup Navigate to the LS6000 DIAGNOSTIC menu and start the Keyboard test Press keys on the keyboard and verify that correct key codes are displayed If the test fails replace the cable or keyboard and test again Test with known good keyboard and cable If it fails replace the LS6000 Attached RS 232 device is not working 1 2 3 4 Check that the device and LS6000 have power Check RS 232 connections at the device and LS6000 Reset the LS6000 and start the DIAGNOSTIC for serial port Attach the wrap plug to the device end of the RS 232 cable and run the RS 232 loop test If the test passes replace the serial device If the test fails go to step 5 Attach a wrap plug to the RS 232 port of the LS3000 and rerun the RS 232 loop test If the test passes replace the RS 232 cable If the test fails replace the LS6000 SOFTWARE DEVELOPMENT The LS6000 interfaces with the application software on the host server through Et
4. the RESET button is accessible Place the LS6000 so that the beeps from the speakers can be heard Place the LS6000 so that the LED indicator on the front panel can be seen Place the LS6000 above grill counter level out of the way of possible spills Mounting Instructions Mounting brackets are provided to facilitate mounting the LS6000 to a wall ceiling or display monitor mounting arm The installer should insure that the wall anchors used with the mounting brackets have the capacity to support 4 3 kg 9 5 Ib This weight is determined by adding a safety margin weight to the weight of the unit Wall anchors with specified weight capacity are available commercially Connections Make sure that all systems are powered off before making or removing any connections to the LS6000 unit Follow the steps below in connecting the devices Connect the VGA cable of the display monitor to the LS6000 Connect the RS232 cable of serial devices to the LS6000 Connect the keyboard device to the LS6000 Connect the Ethernet cable from Ethernet hub or switch to the LS6000 Connect power to all peripheral devices and turn on power Connect power adapter to the LS6000 and power cord to the power adapter Plug the power cord into AC power outlet If necessary reset the LS6000 by pressing the reset button SAS a LS6000 SETUP AND SELF DIAGNOSTIC TESTS Each time the LS6000 is powered on it will run a self diagnostic and display the system informati
5. DRESS SUBNET MASK PORT NUMBER SERIAL menu Baud rate Parity Check Bit number Flow Control Device Driver DIAGNOSTIC menu 1 VGA color test 2 Keyboard test 3 Beeper test 4 COM1 port and driver test Select station address value 0 to 15 This station address is optional It s for easier quick identification of individual stations on top of the IP address Display of status line at bottom of screen on boot ON or OFF Display of Ethernet status icon at bottom right of screen on boot ON or OFF Display of keyboard status icon at bottom right corner of screen on boot ON or OFF Select default font code page tcp437 tcp850 tcp852 or tcp857 For models with CF card build card pictures can be stored on the CF This option enables the build bard viewing function enabled pressing Space and Enter key simultaneously on the bump bar will enter building card viewing function Setup IP address of the unit with numeric keys must match with host PC IP group Setup Subnet Mask with numeric keys default 255 255 255 0 Setup TCP port number with numeric keys must match with application software Select serial port baud rate 2400 4800 9600 or 19200 Select parity check option none odd or even Select bit number option 7 bits or 8 bits Select flow control option none or hardware Select or disable integrated device driver for the COM port Display 256 color palette for checking
6. If the colors displayed are not correct adjust or replace the monitor Display codes of keys entered on the attached keyboard to verify keyboard function If the corresponding key code does not appear check the keyboard connection at the LS6000 If the correct code still does not appear replace the keyboard Test beep sound Adjust beeper pitch on MAIN menu if necessary If device driver is enabled this will setup and test the device with the driver If device driver is disabled connect a wrap plug to the port for testing serial port function If the test fails the LS6000 is not able to work with the attached RS 232 device If the test is passed but the port does not work with the peripheral device check the serial cable for proper connection and pin out 8 5 COM2 port and driver test Same as above 6 Ethernet port test Test Ethernet port function with test utility on host server If the test fails there is a communication problem between the LS6000 and host server Check the IP settings and Ethernet cable connections Note that the LS6000 and host server must be in the same IP group EXIT menu 1 Exit and Save Save the changes made and exit setup 2 Exit discarding changes Discard all changes made and exit setup 3 Load manufacturing defaults Load all setup parameters with default values SYSTEM SETUP Install the LS6000 units as described in HARDWARE INSTALLATION section Setup optional parameters on LS6000 i
7. LS6000 Logic Net eStation Kitchen Video Controller with Ethernet Interface USER MANUAL AND INSTALLATION GUIDE NOTICE The manufacturer of the Industrial Computer makes no representations or warranties either expressed or implied by or with respect to anything in this manual and shall not be liable for any implied warranties of fitness for a particular purpose or for any indirect special or consequential damages Information in this document is subject to change without notice and does not represent a commitment on the part of the manufacturer FCC NOTICE This device complies with Part 15 of FCC Rules Operations are subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation EUROPEAN COMMUNITY CE MARK OF CONFORMITY This product is in conformity with the protection requirements of EU Council Directive 89 336 EEC on the approximation of the laws of the Member States relating to electromagnetic compatibility Logic Controls cannot accept responsibility for any failure to satisfy the protection requirements resulting from a non recommended modification of the product This product has been tested and found to comply with the limits for Class A Information Technology Equipment according to CISPR 22 European Standard EN 55022 The limits for Class A equipment were derived for commercial
8. and industrial environments to provide reasonable protection against interference with licensed communication equipment Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures LOGIC CONTROLS INC 355 Denton Ave New Hyde Park NY 11040 TEL 516 248 0400 FAX 516 248 0443 Email lci logiccontrols com http Awww logiccontrols com IMPORTANT SAFETY INSTRUCTIONS Please read the following instructions carefully and save these instructions for future reference 1 2 Follow all warnings and instructions for installation and operation of the product Unplug this product from the wall outlet before cleaning Use only mild cleaning agents and do not immerse in water Do not use this product near water This product should be operated from the type of power indicated on the power adaptor If you are not sure of the type of power available consult your dealer or local power company Do not allow anything to rest on the power cord Do not locate this product where persons will walk on the cord If an extension cord is used with this product make sure that the total ampere rating of the equipment plugged into the extension cord does not exceed the extension cord ampere rating Also make sure that the total rating of all products plugged into the wall outlet does not exceed the fuse rating We recommend all servicin
9. e applications of the command set Source code of mini applications to answer all how to write questions Free phone and e mail technical support Self diagnostic Automatic power on and diagnostic tests for Internal Memory Communication Integrity Keyboard Connection RS232 ports Internal Beeper Compatible OS Compatible with servers operating in DOS Linux Unix Windows 95 98 ME Windows NT 2000 XP International Operations Downloadable code pages support languages for international operations Universal input 100 to 240VAC 47 to 63Hz switching power supply PRODUCT DESCRIPTION A typical system consists of a host server PC or POS terminal where the application software is installed and a number of LS6000 Logic Net eStation units Each LS6000 unit can be connected to a VGA monitor a keyboard and 2 serial interface devices The LS6000 units communicate with the host server via TCP sockets on Ethernet connections Logic Net commands are sent from the server to display data on the eStation VGA monitor and to read key codes of keys entered on the keyboard Front View Back View 1 peers ag N 1 an 7 F sooper 22 Es To Ethernet Hub tatus Indicator To RS232 Device 2 Reset Button To RS232 Device 1 VGA Output Keyboard Input Power Adapter Input RESET Button Press the RESET button located on the front of the LS6000 to reset the unit and access Setup or self diagnostic tests
10. f necessary for example RS232 baud rate and beeper pitch Setup the LS6000 station address used for quick identification of the station Setup LS6000 IP address subnet mask and port number to the required values Check with system administrator for proper settings Note that the IP address must match the IP group of the host server and the TCP port address must match the port number used by the application software Save parameters and exit setup Verify that the values on the boot up screen shows the correct set up values If not repeat step 2 to 5 to correct the settings The setup for one LS6000 is now completed Repeat as necessary for each LS6000 in the system ensuring a unique IP address for each LS6000 Always verify the setting on the boot up screen Check the host server IP address to make sure that it s in the same IP group as the LS6000 units Setup the server IP address if necessary Setup the application software if necessary including TCP port number setting Run the application software or a test program to verify functions of the system TROUBLE SHOOTING There are no user serviceable components inside the LS6000 Service should be performed only by Logic Controls or qualified personnel certified by Logic Controls The following guide lines will help in identifying the source of a problem VGA monitor display is blank 1 aro D Check that the monitor and LS6000 power supplies are plugged into funct
11. g done on this product be done by qualified service personnel Aside from upgrades or swapping out the compact flash please refer all other servicing to the Logic Controls RMA Dept or a repair provider that has been certified by Logic Controls Unplug this product from the wall outlet and refer servicing to qualified service personnel under the following conditions a When the power cord or plug is damaged or frayed If liquid has been spilled into the product If the product has been exposed to rain or water o If the product does not operate normally when the operating instructions are followed Adjust only those controls that are covered by the operating instructions since improper adjustment of other controls may result in damage and will often require extensive work by a qualified technician to restore the product to normal condition e If the product has been dropped or the cabinet has been damaged f If the product exhibits a distinct change in performance indicating a need for service TABLE OF CONTENTS PEA TURES tdi e dx MR GE ed au e dtd c MC LR 1 PRODUCT cauaa renati men e cai sic uc 3 CONNECTOR 5 niani riii reed cu diia rs n ee iino as e cR n a 5 HARDWARE INSTALLATION 5 tere nuin Duk VR an oaa Gua caa d un e oue 6 LS6000 SETUP AND SELF DIAGNOSTIC TESTS 7 SYS PEM SETUP e
12. ge within these ranges will meet the output requirements and will not cause damage to the supply The power supply output is connected to the LS6000 with locking connectors Nominal Voltage 100 240 V AC Voltage Variation 90 265 V AC Frequency 47 63 Hz 1 Custom driver code in firmware is required for supporting different models of touch screens and will be available in future versions of LS6000 Currently Elo touch screens are supported CONNECTOR PINOUTS Ethernet interface 8 pin RJ45 connector with 2 LED indicators 1 TX 2 TX 3 RX 6 RX 87654321 RS 232 interface 9 pin DSUB male connector 1 DCD 2 RX 3 TX 1 5 4 DTR 5 GND oe DSR 6 9 7 RTS 8 CTS RS 232 interface 8 pin RJ45 connector EIA 561 pin out 1 DSR 12345678 4 GND 5 RXD 6 TXD 7 CTS 8 RTS Keyboard interface 6 pin RJ 11 connector 1 CLK 200 2 DATA 3 No connection 4 Signal GND 5 5 V dc 6 Chassis GND VGA interface 15 pin DSUB female connector 1 Red 2 Green 5 1 3 Blue 5 6 7 8 amp 10 GND 13 H Sync M 14 V Sync DC Power Shielded snap lock mini DIN connector with EMI RFI suppression 5 5 V dc 8 45 V dc VN 3 GND 6 GND HARDWARE INSTALLATION Ethernet Hub Server LS600 Component Placement The following is recommended when you plan the Logic Net setup e Place the LS6000 so that you can use the mounting brackets located at the bottom of the unit Place the LS6000 so that
13. h different pitch for easier identification 16 automatic timers individually displayable at any location on the screen 4 display modes 40 column 60 column 80 column and 106 column Display bit map files for build card display support Embedded Custom Functions Embedded custom functions available through downloadable firmware upgrade Executes complex sequence of operations with a single command from the server Reduces application software burden Performs real time tasks more efficiently for enhanced system throughput Small Size Module size 6 3 W x 5 1 L x 1 0 H 160 x 130 x 25mm Flexible Installation Table Mount Wall Mount Display Bracket Mount and Under the Counter Mount Highly Secure Designed to prevent illegal data copying through externally accessible removable media The internally installed compact flash optional is for picture storage Program code and data are not stored in the compact flash Enhanced security through proprietary command set Immune to viruses Minimize Obsolescence Problems Upgrade LS6000 units with remote downloadable firmware and character fonts Extensive Free Software Development Support High level language software utilities allow developers to write application software with Visual Basic or Visual C OCX control covers all of the Logic Net s command sets Multi tasking programs are supported Command test program with source code to illustrate th
14. hernet TCP socket and proprietary Logic Net eStation command set The command set is available to software developers on request As the LS6000 is derived from Logic Net software development support tools are similar to those for Logic Net such as the OCX control Application software written for Logic Net can be easily converted to work with LS6000 with minimal changes For further assistance please contact support logiccontrols com Logic Controls recognizes that a highly reliable video network with zero interruption is desirable for all applications Unfortunately due to numerous abnormal conditions such as electrical transients and intermittent network connections the TCP socket between the host server and LS6000 may be lost The result is loss of communication between the application software and the LS6000 hardware If such interruption occurs Logic Controls recommends that the application software should close the TCP socket and then open the socket again to continue communication SPECIFICATIONS Front View Beeper TM Status Indicator Reset Button Back View LS 9g To Ethernet Hub To RS232 Device 2 To RS232 Device 1 VGA Output Keyboard Input Power Adapter Input MECHANICAL INTERFACE Weight 2 25lbs To host server Ethernet 10BaseT Dimension in Inches 6 3W x 1 0H x 5 1D VGA Port Standard VGA Keyboard PS2 ELECTRICAL Power Adapter Serial Port RS232C I
15. ioning AC outlets Adjust the contrast controls Check that the VGA cable is plugged in properly Check that the LS6000 is properly connected to its power supply adapter If the LS6000 is connected to a power supply but the power LED is off replace the power supply Press the RESET button on the LS6000 to check whether boot up screen is displayed Replace the LS6000 if necessary One VGA monitor display is solid blue or frozen 1 OVP o Reset the LS6000 and check the system information on the boot up screen and status screen Check that the LS6000 IP address is correct and unique If the host IP address is not shown in the status screen check Ethernet cable connections Check the Ethernet cable connections at the LS6000 and at the Ethernet hub or switch Check host server application software setup Restart software if necessary and test again Two or more but not all station displays are solid blue or frozen 1 Reset the LS6000s at the stations experiencing problems and check that the LS6000s IP addresses are correct and unique Check the Ethernet cable connections at the problem LS6000s and at the Ethernet hub or switch Check host server application software setup Restart software if necessary and test again All station displays are solid blue or frozen 1 2 3 Check that the Ethernet hub or switch is connected to the host server properly Check that host server IP address matches the LS6000
16. nput voltage 100 to 240VAC Baud Rate 2400 4800 9600 19200 Input frequency 47 to 63 Hz Parity None Input current lt 1000mA 120VAC Data Bits 8 Output voltage 5VDC CONNECTORS Output current 2A max General All connectors and cables Ripple voltage lt 100mVp p oe or with screw Power 4 pin Mini DIN Se Ethernet 8 pin RJ45 Operating temperature 5 C to 40 C RS232 DB9 male for COM1 amp Relative humidity 8 to 80 RJ45 for COM2 Storage temperature 0 C to 60 C VGA Standard high density Relative humidity 5 to 80 DBIS Temale Keyboard 6 pin RJ11
17. on on the screen There is also a ROM based setup and diagnostic program that is used to set system parameters and provide problem determination information To enter the setup and diagnostic program press the system RESET button and as soon as the system information screen appears quickly press Delete or Down Arrow key on the bumpbar or keyboard MAIN 75 OFF ON 2520 ien ien ien tcp437 OFF Copyright 2006 Logic Controls Inc There are 5 setup menus MAIN ETHERNET SERIAL DIAGNOSTIC and EXIT The menu currently displayed has the menu name highlighted in reverse video on the menu bar across the top of screen Use left and right arrows to select the menu Use up and down arrows to select menu items Menu items that can be configured are shown in yellow color and will be highlighted in reverse video when selected Use keys or 0 1 keys to change the value For certain items such as IP address the numeric keys can be used to enter the values When configuration is finished press F10 or Ctrl key to save the settings and exit MAIN menu VGA frame rate Select VGA frame rate 60Hz 65Hz 70Hz or 75Hz Screen cursor Select power on screen cursor status ON or OFF Beeping on boot Select beeper status on boot ON or OFF Beeper pitch Select beeper pitch value 2000Hz to 3000Hz 7 Station Address Status line Ethernet icon Keyboard icon Font code page Build card pictures ETHERNET menu IP AD