Home

Biopac Student Lab Catalog

image

Contents

1. i A An integrated system 5 s hardware software 3 lak b manual that revolutionizes life science education UJ fe e av 1N3anig BIOPAC Systems Inc Registered 1S0 00 200 www biopac com r m Y Wu p J 0 J VOb 3E 0 5 22 EE 223 210 E BINE EL ELO Integrated Hardware Software amp Curriculum f Ja EMPOWER YOUR Students Record Live Physiological Data L Focus on Key Principles STUDENTS WITH Develop Real World Skills d INTERACTIVE Use Clinical amp Standardized Techniques MULTI MEDIA Extensive Experiment Range Instructor and Student Prep Tools LESSONS Millions of Successful Lab Hours Proven to Increase Confidence amp Proficiency STUDENTS REGORD FROM THEIR OWN BODIES ANIMALS OR TISSUE PREPS Easy Setup Great Data Add Student Designed Experiments Create Your Own Lessons Use Advanced Analysis COMPLETE SYSTEMS FOR LIFE SCIENCE LABS Physiology Exercise Physiology amp Biomechanics Biology Pharmacology amp Toxicology Psychophysiology Biomedical Engineering Neuroscience Nursing Used in thousands of labs worldwide Incorporated in mayor published lab manuals Runs on Windows or Mac WWW biopac com l A BIOPAC E Systems Inc Table of Contents Page S1 BSL System Overview 2 t Applications BSL Hardware 23 Lessons Summary 43 Index 47 BIOP
2. equipment in a modular flexible co n The Visceral Smooth ii re ee 22 Muscle M ah a D Se Ur j lesson Drug effect and marker summary guides students through the entire recording and analy sis process Students can also electrically stimu late tissue preparations including field stimula tion with the BSL Stimulator Interface with Ussing chambers for ion transport studies Record and also analyze data trom isolated heart and lung experiments Use the Nerve Chambers page 38 for compound action potential studies The system can record monophasic action potentials and spontaneous nerve activity New Tissue mm The following hardware suggestions will enable you to perform a wide variety of applications targeted for pharmacology amp toxicology Use BIOPAC lessons or easily create your own experiments with the BSL PRO software included with each system Order the core package or select items a la carte See BSL Hardware page 23 40 for all available transducers electrodes and accessories Pharmacology amp Toxicology Core BSLPHA W Win or BSLPHA M Mac Basic BSL System with BSLCBL8 substituted for SS2LB BSLBSC p 8 Airflow Filters 10 pk AFT1 p 34 Airflow Mouthpieces 10 pk AFT2 p 34 Airflow Nose Clips 10 pk AFT3 p 34 Airflow Transducer SS11LA p 27 Pressure Transducer SS13L p 27 Calibration Syringe 600 ml AFT6A p 34 Force Transducer 200g SS65L p 31 Lead unshielded x 2 LEAD110
3. 42 pin OAM subjects as isolation can be brohen SS9LA for animal use only BSLTCI7 5 pin Nihon Kodek SS70L Isolated Female BNC Attenuation 10 Input range max 10V BSLTCIB Zpin Narco SSOLA Unisolated Male BNC Attenuation 10 BSLTCI9 8 pin Fukada 30 Input Range max MP36 45 20 V BSL TCI11 6 pin male Hugo Sachs and Harvard Apparatus p g F BSLTCI12 5 pin 240 degrees Thornton MP35 10 V BSL TCI13 Piezo BNC iWorx PT100 BSL TCI14 1 4 phono socket Lafayette Force 3 5 mm phone plug adapter BSLCBL5 BSLTCI15 5 pin DIN Vernier Use this 3 5 mm phone plug adapter to interface the MP3X with BSLTCI16 BT Connector BIOPAC RXPROBEO2 and Vernier equipment that outputs high level voltage signals The built in BSLTCIT 5p EGON ica p 5 BE Pis i BSLTCI18 2x2 mm sockets Mercury Strain Gauge or Indium Gallium attenuation of 1 200 translates 10 V to BSL TCI19 6 pin mini DIN Intalitacl 50 mV Included with the TSD122C BSLTCI20 3 5 mm phono jack Intelitool l BSL TCI21 BNC BIOPAC RXPROBE01 and 3rd party pH probes BSL TCI22 Breadboard Electrode BIOPAC Breadboard SS39L to LEAD SS2LB Note All company names listed above are Input Adapter for Research Amplifiers BSLCBL14A Use this 3 5 mm phone plug cable to inter Qustom Input Interface SS KIT IN face with BIOPAC research amplifiers via the IPS100C Isolated Power Adapt third party transducers to the MP36 The kit comes with a Supply Contact BIOPAC for details
4. i Fmulate standard lab equipment displays chart recorder oscilloscope options can be expanded to allow for X Y plotter and metabolic cart sophisticated measurements student directed Set up digital I O channels to receive trigger information from products experiments alternate curriculum and like SuperLab or E prime or control pumps lights etc research level studies e Select automatic file saving save to a network server so students can access and analyze data outside the lab Control output functions such as sound digital pulses and stimulation low and high voltage Use stimulation features for human or animal subjects visual auditory mechanical or electric Set the stimulator to automatically start with the recording or for manual start and stop within the experiment Set automatic stimulator event markers to note the stimulus frequency and pulse width Use filtering options to allow students to develop and display the filter response online and offline Choose External or Analog from any channel triggering options Show or hide menus and analysis features based on the lesson requirements Analysis Perform online measurements of heart rate systolic diastolic mean Oo blood pressure dP dt max and min with the rate detection features e Identify frequency components of a signal i e EEG alpha beta delta with FFT functions Use the Equation Generator to calculate values such as RER and
5. output and continuous blood pressure lessons A Heart Sounds lesson allows students to listen to and record heart sounds while comparing them to the ECG Suitable for inquiry based active learning in 2 yr amp 4 yr RoR oat Tema complex There are also lessons for the Cardiac output data Wingate test and Blood Pressure Response to Isometric Straining Exercise Record car diac output from human subjects connect the bioimpedance electrodes to a subject and record stroke volume and cardiac output in real time pre and post exercise There is also an option for continuous blood pressure monitoring during exercise Biomechanics Students can use the new Reflex Hammer in conjunction with EMG recordings to compare responses and reflex actions For advanced studies purchased the Advanced System and have found the student labs helpful in explaining and demonstrating physiological concepts and current technology Personally have been using the PRO software for my own research purposes have instrumented an old cybex isokinetic ergometer with a force transducer to measure force and a potentiometer to measure joint angle Data acquisition has been going very smoothly have been quite impressed with the PRO software and its abilities have set up a calculation channel that accounts for gravity s affect on limb weight at all joint angles throughout a range of motion This allows me to accurately estimate muscular resist
6. Field Stimulation Electrode BSLSTIMHLD 2 2 J This tissue holder with built in Electrodes Platinum rings Ring size 5mm Contact BIOPAC for modular multi channel tissue bath stations and independent heating circulator field stimulation electrodes P i Ring spacing 2 0 cm works with Tissue Bath Stations Connector BNC and the BSLSTMB Stimulator AM IIOW amp Udo dild d Airflow Transducers SS46L SS52L See also the Medium Flow Airflow Transducer SS11LA on page 27 Perform a variety of pulmonary measurements relating to airflow lung volume and expired gas analysis of small animals or exercising humans Each Airflow Transducer consists of a flow head a precision highly sensitive differential pressure transducer SS40L and 1 8 meter tubing Airflow Transducers connect directly to a breathing circuit or plethysmogram chamber for airflow and lung volume measurements connect a short airflow cannula to the flow head RX237 series novel design greatly reduces thermal inertia and minimizes condensation no heater required SS52L is a heated pneumotach and includes a 6 V power supply AC137 page 40 For switchable or replacement heads see RX Series part for head only Part Head Linear Range Dead Space Approx Flow 10 mm H20 Port OD Length Weight SS46LA RX237B 1 L min 0 6 ml 1 2 L min 5 mm 40 mm 13 8 g SS48LA RX237D 10 L min 2 0 ml 12 L min 8mm 54 mm 21 8 g SS50LA RX237F 100 L min 9 0 ml 90 L min 1
7. See Lesson BSL2 page 43 The multi lead ECG cable connects to standard amp snap connector disposable electrodes EL503 M i series to simultaneously record Leads I II III SW aVR aVL aVF plus one alternating precordial chest lead V 1 6 for 12 lead studies Incorporates a Wilson terminal Each 1 meter pinch lead terminates in a yoke connected to a 2 meter cable that has three Simple Sensors three input channels required _ See Lesson HOL page 43 af Connect directly to the MP36 Data Acquisition Unit Electronic Stethoscope Transducer SS30L This is a standard clinical stethoscope with a built in electronic microphone to simultaneously capture sound Listen to heart sounds and Korotkoff sounds and simultaneously record the sound data a variety of acoustical signals can be recorded When recording ECG you can correlate the timing of the heart sounds with the cardiac cycle Use with the SS19LA L Blood Pressure Cuff to record Korotkoff sounds for easy determination of systolic and diastolic blood pressure Microphone Bandwidth 20 100 Hz does not inter fere with stethoscope earphones See Lessons BSL16 BSL17 H04 H21 pages 43 44 i See also the Physiological Sounds Microphone SS17L below for a higher bandwidth alternative and the Speech Frequency Microphone SS62L page 30 Human safe Stimulation Electrode HSTMO1 Provides a superior degree of safety and comfort when using th
8. Austria med NATIC GmbH Harthauser Stra e 2 D 81545 M nchen Germany Tel 49 089 6 42 29 58 Fax 49 089 6 42 29 78 E mail med Natic t online de Web www med natic de Bulgaria ELPAK Medical amp Special Equipment 2 Ivan Bogorov Str Varna 9002 Bulgaria Tel 359 52 602360 Fax 359 52 699060 E mail elpak elpak bg Web www elpak com Czech Republic Slovakia and Hungary EduProduct s r o V clava Rabase 868 2 2 01 Kladno Czech Republic Tel 420 732 860 576 E mail info eduproduct com Web www eduproduct com France B CEROM 55 rue du Faubourg Saint Denis 5010 Paris France T l et Fax 33 Ol 42 23 20 54 E mail info cerom fr Web www cerom fr Germany BIOPAC Systems Inc Germany Alice Phung European Sales Executive Leipziger Str 34 45145 Essen Germany Tel 49 0 201 85835708 Mobile 49 0 163 2438289 E mail AliceP biopac com Web www biopacsystems de or Www biopac com Greece St Tsimpos Ltd Medical amp Scientific Instruments 94 Constantinoupoleos Str 546 42 Thessaloniki Greece Tel 30 23 0 888630 Fax 30 23 0 88863 E mail tsimpos tsimpos gr Web www tsimpos gr Italy EMS srl Via Giuseppe Ceneri 13 Bologna 40138 Tel 39 05 1398925 Fax 39 051342953 E mail tampieri emsmedical net Web www emsmedical net Poland ELO SERWIS ul Sotta Kazimierza Sokola 2A PL 02 90 Warszawa NIP 951 174 02 57 Tel Fax 48 22 649 11 85 E mail biuroQeloserwis p
9. Hand Switch SS10L p 26 Headphones OUT1A p 26 Pulse Transducer SS4LA p 26 Respiratory Effort Transducer SS5LB p 26 Perform 28 or more lessons with this core package Muscular BSL1 Standard amp Integrated EMG H07 EMG Contractions Active Learning H27 Facial EMG H34 EGG Electrogastrogram H36 Muscular Biofeedback Cardiovascular BSL5 Components of the ECG Lead Il BSL6 Leads Il Ill amp Einthoven s Law BSL7 ECG amp Pulse BSL16 Blood Pressure amp Korotkoff Sounds BSL17 Heart Sounds amp Cardiac Events H08 Dive Reflex Active Learning H23 Signal Averaged ECG H32 Heart Rate Variability Neurophysiology BSL3 EEG Relaxation amp Brain Rhythms BSL4 Alpha Rhythms in the Occipital Lobe BSL9 GSR and Polygraph BSL10 EOG Eye Movement Saccades amp Fixation BSL11 Reaction Time BSL14 Biofeedback Relaxation amp Arousal H10 EEG amp Hemispheric Asymmetry H11 Mirror Test EDA Sensory motor learning H12 EOG Saccades amp Displacement H13 EOG Visual Tracking vs Imagination H14 Ocular Fixation while reading H15 Ocular Fixation while viewing an image H16 Reflexes amp Reaction Time Active Learning H24 Habituation Biomedical Engineering H02 Compartmental Modeling H20 BME Filtering H33 FFT Fast Fourier Transform See page 43 45 for a description of all available lessons Increase your lab options with Cardiac Output Sensor SS31L p 29 Noninvasive Blood Pressure Monitor NIBP100D p 32 Psych Variable Assessment T
10. MP45 3 cm x 18 cm x 10 cm 0 3 kg Additional Specs MP36 Only Analog Output Back panel DSUB 9m labeled Analog Out Voltage Output Range 10 V to 10 V Resolution 16 bits Pulse Output Width variable 50 usec 100 msec Repetition variable 100 usec 5 seconds Pulse Level Adjustable from10 V to 10 V With BSLSTMB Stimulator 0 100 V Input Triggering Options External Trigger Back panel BNC labeled Trigger TTL positive or negative edge Analog Trigger Any input channel front panel CH 1 CH 4 Digital Trigger Any of the eight input lines back panel DSUB 25m Electrode Check Impedance Range 0 1 MO Checks impedance between Vin and GND Vin and GND See www biopac com for detailed specifications Stimulators Biopac Student Lab Stimulator BSLSTM The BSL stimulator can be used on Human Animal Organ or Tissue Preparations for the following physiological measurements Twitch sub threshold Tetanic contraction Twitch threshold Muscle tension length versus force Maximum twitch response Fatigue Single twitch summation Nerve conduction velocity Field Stimulation Stimulator Features Safety locking key switch to establish the operating range Output via the front panel BNC female connector Set the stimulus voltage level and view it on the digital display Output pulse trains 1 254 pulses continuous or individual pulses Lock pulse width and frequency safety limits for your protocol Re
11. Stroke Volume Gait Analysis including Heel Toe Strike Range of Motion Acceleration Velocity Distance programs medical schools and nursing programs T T r gt F Ie yomechanics xercise pnysiology Respiratory amp Pulmonary Function 3 zm LINGUS The BSL includes a range of experiments Term for pulmonary function and Gas Analysis studies Detailed lessons guide students through the classical pulmonary function tests including tidal volume inspiratory capacity expiratory capacity functional residual capacity vital capacity total ity forced vital it ae T n ee Respiratory exchange ratio forced expiratory volume FEVA 2 3 and Maximal Voluntary Ventilation MVV Gas Analysis ziBixg Eile Wi goceng sins Ec E Jaer Use the new Gas Analysis Module to create TE a powerful metabolic analyzer cart for students to measure expired O2 and CO and use lessons for VO Respiratory Exchange Ratio and Basal or Resting Metabolic Rate Combine metabolic and cardiac output measurements to give stu Ready Grid Off dents a detailed view of a variety of l i ca Airflow Pressure Volume loop cardiopulmonary responses If your protocol examines CO above 5 or requires high speed response contact BIOPAC to discuss the full range of gas analyzers Cardiovascular The BSL System includes many ECG lessons including 12 lead ECG cardiac
12. X X X X A X X X X X X A X X A X X X X X X X x BKK eK KK KKK OK KKK KK XX XxX Xx Exercise Phys To od eo c 2 a Biology DNXCHIOICICICICHCIENOI 8 Psychophys Biomed Eng Pharm amp Tox HScS MP45 See the page indicated for an overview of each discipline including lessons the Core Package supports and suggested hardware options and potential applications 41 42 transducer accessory TA packs The following TA Packs are suggested transducer accessories for any core package to increase the application potential of your lab Each TA Pack allows you to perform the additional lessons listed or you can create your own experiments All items can be ordered individually See the Core Packages summary p41 For a full list of hardware options see the BSL Hardware section page 23 40 For an overview of each lesson see the Lessons Summary page 43 46 Human Physiology TA BSLHPY TA This hardware Stimulator BSLSTMB page 25 Stimulation Electrode for Humans HSTMO1 page 28 Finger Twitch Transducer SS61L page 30 Reflex Hammer SS36L page 30 Animal Physiology TA BSLAPH TA This hardware Cardiac Output Sensor SS31L page 29 Bioimpedance Strip Electrodes EL506 10 80 pk page 37 Exercise Physiology TA BSLEXP TA This hardware Multi lead ECG Cable 12 lead SS29L page 27 Cardiac Output Sensor SS31L page 29 CO amp O Analysis Module
13. for tissue bath and isolated organ experiments frog gastroc nemius and human finger twitch experiments The SS12LA 4 will operate in five ranges 50 g 100 g 200 g 500 g or 1 000 g is extremely stable ai incorporates impact and drop shock protec tion to insure against rough laboratory handling The SS12LA mounting rod can be attached in three different locations two on the top and one on the end surfaces of the transducer to provide a variety of mounting options The SS12LA includes two aluminum S hooks one has a 1 26 mm 032 wire diameter the other is 2 mm 051 Sensitivity Range Noise 1 Hz LP 50g 1 0 mg 100 g 2 0 mg 200 g 4 0 mg 500 g 10 0 mg 1 000 g 20 0 mg Temperature Range 10 C to 70 C Dimensions 19 mm x 25 mm x 190 mm See Lessons A02 A04 A05 A09 A15 H06 pages 43 45 See the Tension Adjuster HDW100A on page 31 See the Fixed Range Force Transducers SS63L SS66L on page 31 Pressure Transducer SS13L Measure direct arterial or venous blood aA pressure in animals or record pressure yr gt changes within a closed system such as Ls 4 an organ or tissue bath system Connect E tubing via male Luer lock fittings The 8 8 disposable transducer has a 30 cm cable that attaches to a reusable cable Supplied non sterile but can be cold sterilized Range 50 to 300 mm Hg 10 C to 40 C 67 mm long X 25 mm wide Operating temperature Transducer dimensions Replacement Element RX
14. 100020 China Tel 86 10 58790590 Fax 86 10 58790595 E mail info upwardstek cn Web www upwardstek cn India Gentech Marketing and Distribution P Ltd B 1 16 amp B 117 RG Complex Plot No 2 D B Gupta Road Motia Khan Pahar Ganj New Delhi 110005 India Tel 91 1 1 47563575 Fax 91 1 1 47563576 E mail gentechmd yahoo com Japan B Zero C Seven Inc The Hexagon F 5 4 7 Akasaka Minato ku Tokyo 107 0052 Tel 81 3 3560 7747 Fax 81 3 3560 7748 E mail info 0c7 co jp Web www 0c7 co jp South Korea BIOPAC Systems Inc 42 Aero Camino Goleta CA 93117 USA Tel 805 685 0066 Fax 805 685 0067 E mail info biopac com Web www biopac com Taiwan Upwards Biosystems Ltd 8 F8 No 237 Sec 2 Fuxing South Rd Taipei City 10667 Taiwan Tel 886 2 275558 Fax 886 2 27557566 E mail info upwards com tw Web www upwards com tw Thailand Harikul Science Co Ltd 694 Soi Rajchadanivet 24 Pracharatbumpen Samsaennok Huay Kwang Bangkok 10310 Thailand Tel 0 2274 2456 Fax 0 2274 2443 E mail sales harikul com Web www harikul com 4 2014 Worldwide distribution for a world class product You may contact an authorized international distributor directly or through www biopac com EUROPE BIOPAC Systems Inc European Office Aleksandar Dimov European Sales Executive 59 Bratja Miladinovi Street Varna 9000 Bulgaria Mobile 359 898 664 043 Fax 359 52 624 554 info biopac com www biopac com
15. Biology page 14 Exercise Physiology amp Biomechanics page 16 Psychophysiology amp Neurophysiology page 18 Biomedical Engineering page 20 Pharmacology amp Toxicology page 22 Suggested applications are outlined on the following pages along with a CORE package with hardware targeted for each discipline A BSL Lab Manual is included with each system or you can choose from major published lab manuals that l Main 5e ISBN 10 0 321 93556 X ISBN 13 9780077427320 Auteur Sous la direction de incorporate BSL experiments Plus PRO Lessons are available Cat ISBN 10 0 321 93557 8 Michel DAUZAT online and you and your students can develop new applications Pig ISBN 10 0 321 80412 0 Editeur SAURAMPS ISBN 2840234041 budget beating two channel systems Start with an Intro System and perform 6 guided BSL lessons L1 L3 L4 6 L10 Choose a Health Sciences System to add spirometry blood pressure and dynamometry and perform 11 BSL lessons L1 L6 L10 L12 13 L16 17 Plus use PRO lessons or create your own See descriptions on pages 43 46 Intro System BSLINTRO and five pack BSLINTRO5 Health Sciences System BSLHSCS and five pack BSLHSCS5 Data Acquisition Unit MP45 BSL Software BSL Lab Manual Complete BSLINTRO Headphones 40HP Airflow Transducer SS11LA with Electrode Lead Sets 2 x SS2LB Disposable Electrodes EL503 Accessories AFT6A 10 pks AFT1 AFT2 AFT3 Blood Pressure Cuff SS19L 100 pk Abrasive Pad
16. Simple Sensor connector cable and components to properly inter face with quarter half or full bridge transducers pressure force Touchproof Y Adapter CBL204 This Y electrode lead adapter 25 cm long provides two Touchproof sockets and strain acceleration sound etc one Touchproot plug Use to connect See the BSL TCI series for existing multiple electrode sites such as Vin and transducer interfaces GND from BSLCBL8 9 page 36 to a glass microelectrode Connect multiple CBL204s to reference three or more electrode leads to the same input or output 40 USB Cable CBLUSB 2 5 meter replacement USB cable connects the MP36 to a USB Port Includes and provides EMI protection to maintain BSL System certified safety rating CE EMC power transformers 1 IEC 60601 1 Certified AC300A 12V 1 25 amp for MP36 to mains wall outlet Included with each BSL System and GASSYS2 Gas Analysis System Specify power cord ACCORD HUS Hospital grade USA or ACCORD EURO Europe 6V 1 50 amp AC137A For heating elements to mains wall outlet Powers the heating element for the SS52L pneumotach or RX137H1 replacement head Specify power cord ACCORD US USA or ACCORD EURO Europe BSL Laboratory Manual BIOPAC lessons provide online instructions and real time prompts to guide students through setup calibration and recording This Laboratory Manual provides further details for record
17. evoked response applications and includes BSLCBL5 page 39 to interface with the BSL System The stroboscope operates from zero to 12 000 flashes a minute and can generate or respond to a TTL synchronizing signal I O Ports TTL Sync input and output 3 5mm phone jacks Flash Duration 30 usec Power Battery built in rechargeable Battery Life 60 hours at 100 strobes sec BSLCBL5 included connects to an analog input CH1 CH4 to record the strobe flash as a pulse and trigger the MP unit Body Dimensions 9 3 cm wide x 9 cm high x 23 cm long Weight 1 1 kg Interface Cable See Lesson H22 page 44 See Lesson H18 page 44 The NIBP100D is a stand alone noninvasive blood pressure monitoring system that provides a continuous beat to beat blood pressure signal recorded from the fingers of a subject Uses a double finger cuff sensor that is comfortable for the subject to wear and easy to place on the hand three included cuff sensors fit small to large fingers The system outputs a continuous blood pressure waveform that is similar to a direct arterial pressure waveform Monitor displays values for systolic diastolic mean blood pressure and heart rate Add BSL TCI5 to use with an MP36 System NIBP1OOD System includes Blood Pressure Module with external mains power and interface cables Finger cuff sensors 3 small 10 18 mm medium 18 24 mm and large 24 28 mm BP cuffs for calibration 4 xs 12 19 cm small 17 25 c
18. i Speech Frequency Microphone SS62L Use this precision microphone for speech frequency analysis and other acoustic studies Requires continuous high speed sample rate use with the _ MP36 and MP35 only Frequency Range 60 12 000 Hz Impedance 600 Ohms Type Cardioid Cable 6 meters On Off Switch none See also Physiological Sounds Microphone SS17L and Electronic Stethoscope Transducer SS30L on page 28 Fixed Range Force Transducers SS63L SS66L Use force transducers for in vitro tissue bath studies in vivo force measurements and other applications where low noise accuracy and repeatability are critical The most sensitive units are ideal for use with small preparations such as aortic rA rings When fine tension and position adjustments are required use the Tension Adjuster HDW100A page 31 Part Full Scale Range FSR Noise with 10 Hz LP Filter Noise with 1 Hz LP Filter SS63L 50g 2 5 mg 1 0 mg SS64L 100 g 5 0 mg 2 0 mg SS65L 200 g 10 0 mg 4 0 mg SS66L 500 g 25 0 mg 10 0 mg Temperature Range 10 C to 70 C Weight 250 grams Mounting Rod 9 5 mm dia variable orientation Dimensions 100 mm long x 19 mm wide x 25 mm thick See Lessons A02 A04 A05 A09 A15 H06 pages 43 45 See also the Variable Range Force Transducer SS12LA page 27 eneumogran Transducer SS67L i Capture respiratory signals from small unconscious animals just lay them on top of the sensor pad Idea
19. in place ADD204 For EL254 and EL254S 4 mm ID 19 mm OD ADD208 For EL258 and EL258S 8 mm ID 22 mm OD a g g For the complete range of BIOPAC electrodes including radiotranslucent MRI compatible options visit www biopac com or electrodesales com ge Use for added convenience Tae and hygiene get the same BEN lI signal transmission as reusable electrodes Each peel and stick electrode is pre gelled with hypoallergenic gel and intended for one use only Snap fastener attaches to BIOPAC s SS2LB electrode leads General purpose Electrodes EL503 Included in every BSL System pack of 100 Used in over 25 Lessons These unique electrodes provide excellent signals and are suitable for all biopotential and nerve conduction recordings 35 mm diameter vinyl tape 10 mm contact area EL503 100 pack EL503 10 1 000 pack See the Student Accessory Pack BSL ACCPACK page 34 as a packaged alternative for consumables Paired Electrodes EL500 Use for general purpose EMG measurements nerve conduction measurements and cardiac output Spacing center to center 41 mm x 82 mm x 1 5 mm foam 25 pairs pack See Lesson H21 page 43 Stress Test Electrodes EL501 Use for short term recordings where the subject may be in motion or when electrodes should be closely placed such as multi channel ECG EGG EMG or EOG recordings 38 mm diameter mounted on 1 5 mm thick foam with strong adhesive 50 pack
20. including force and angle of limb movement Students can listen to the sound of the electrical activity coming from muscle as they squeeze a hand dynamometer and equate changes in sound with changes in force Add the BSL Stimulator and human safe stimulation electrode for a variety of F muscle stimulation experiments Include visual and auditory feedback with touch for Muscular Biofeedback studies Interface with Existing Equipment The BSL System offers over 60 industry standard transducers Further the system easily interfaces with other major amplifier and transducer manufacturers encompassing the most commonly used exercise physiology lab products such as force plates Ergometer modified to record ergometers motion analysis systems and metabolic WAnT using BIOPAC Photo courtesy A Zidermanis PhD formerly at Parker College of Chiropractic carts The BSL System can trigger or receive trigger information from other equipment For interfacing choose from a variety of ready made connectors and cables or use the custom connector kit page 39 BIOPAC support staff can help determine the appropriate interface for any complete system exercise physiology amp biomechanics The following hardware suggestions will enable you to perform a wide variety of applications targeted for exercise physiology amp biomechanics Use BIOPAC lessons or easily create your own experiments with the BSL PRO software included with each sys
21. liter chamber screw fixture am 1 gi em j X ye 4 i AI ATA AN 4 ml Z ATY H ececnnc CSosvull I 0 yA bt 4 BE See gas calibration options on page 35 GASCAL and GASREG The GASSYS2 can measure both O2 consumption and CO pro duction in real time CO production is measured to a 5 maxi mum for RER or RQ calculations and real time VO2 measure ments can be performed on subjects at rest or exercising If your protocol examines CO above 5 or requires high speed response contact BIOPAC to discuss the full range of gas analyzers See SS1ILA Airflow Transducer on page 27 Disposable Bacterial Filters 22 mm ID OD AFT1 Use between the Airflow Transducer SS11LA and the 22mm disposable Mouthpiece AFT2 to remove airborne bacteria Ports 22 mm ID OD AFTI Pack of 10 AFT1 250 Pack of 250 Disposable Mouthpieces 22 mm OD AFT2 Connects to the Airflow Transducer SS11LA via the disposable Bacterial Filter AFT1 AFT2 Pack of 10 FT2 250 Pack of 250 2 AA Disposable Nose Clips AFT3 Plastic clip gently squeezes the nostrils shut Use with the Airflow Transducer SS11LA AFT3 Pack of 10 AFT3 250 Pack of 250 Gays anama RA 9 RCT 12 PCT IX LIQ HIO naape A92 AA see Lessons BSL12 BSL13 BSL15 H29 H19 pages 43 44 BSL Accessory Pack BSL ACCPACK Have students purchase their own disposable accessories for hygenic purposes and reduce
22. more than 100 signal and calculation channel Presets Establish the recording parameters sample rate duration of experiment lesson 3 Add instructions to the journal students will follow your lesson plan A Save the file as a template students open the file with your settings in place re Fd asma NOME E End irim iam eg Wurm minii ee a i er he er nas pp ny Pri ATA Lo E n ri H men m Jig ud em Har gm ELI ass Pen eb BCHLT Beal Tml em nam Farh BaH Ep m lU LEN Leni ecl ae Mii F GRE en Bis E EXE it Pe DOF remm ema muda pa Pease rH rERUE bugTVE Mead n Calculation Presets Signal Presets the lab experience the biopac student lab student friendly amp research compatible The multi level learning features of the To enhance any lesson consider these options Biopac Student Lab along with its proven f Control success in thousands of labs worldwide e Listen to the sound of EMG and other signals to emphasize a concept make the BSL the ideal teaching solution e Utilize multiple display modes to optimize visual feedback for the BSL Lessons cover scientific fundamentals signal type in real time or offline Select chart scope or X Y plot and simplify recording and analysis so your overlap segments or channels histogram or FFT display as vertical students can focus on lab objectives As or horizontal bar graphs or numeric values show filtered EEG data students advance BSL recording and analysis ea dd
23. p 36 Leads shielded x 2 LEAD110S W R p 36 Needle Electrodes x 3 EL452 p 38 Nerve Chamber NERVE2 p 38 Recording Nerve Cable BSLCBL4B p 39 Stimulator BSLSTMB p 25 Stimulator Nerve Cable BSLCBL2A p 39 Stim Electrodes for animals ELSTM2 p 38 Perform 30 or more lessons with this core package Muscular A03 Frog Gastrocnemius A05 Visceral Smooth Muscle A11 Resting Potential from Crawdad Manual A15 Earthworm Smooth Muscle BSL1 Standard amp Integrated EMG H07 EMG Contractions Active Learning H27 Facial EMG H34 EGG Electrogastrogram Cardiovascular A04 Frog Heart A09 Turtle Heart BSL5 Components of the ECG Lead Il BSL6 Leads Il Ill amp Einthoven s Law H08 Dive Reflex Active Learning H23 Signal Averaged ECG H32 Heart Rate Variability Pulmonary Function BSL12 Pulmonary Function Vol amp Capacities BSL13 Pulmonary Flow Rates FEV and MW Neurophysiology A01 Frog Pith amp Prep A02 Frog Nerve A06 Cockroach Nerve A08 Earthworm Action Potential A14 CPG Hornworm BSL3 EEG Relaxation amp Brain Rhythms BSL4 Alpha Rhythms in the Occipital Lobe BSL10 EOG Eye Movement Saccades amp Fixation H10 EEG amp Hemispheric Asymmetry H12 EOG Saccades amp Displacement H13 Visual Tracking vs Imagination H14 Ocular Fixation while reading H15 Ocular Fixation while viewing an image See page 43 for a description of all available lessons Increase your lab options with Cardiac Output Se
24. sterilization is required 28 gauge stain less steel needles with a flexible cable termi nating in standard Touchproof connectors which connect to the SSILA shielded electrode lead adapter or BSLCBL8 or BSLCBL9 EL450 Unipolar Teflon coated Teflonu coating covers the entire length of the electrode exposing just the tip for effective isolation of subcutaneous recording points Dimensions 300 um dia 4 cm long 1 2 mm x 61 mm lead EL451 Bipolar Teflon coated Use when recording from a single site as in studies of single muscle fibers Dimensions 460 um dia 3 0 cm long 1 2 mm x 91 mm lead EL452 Unipolar Uncoated Use for small animal preparations Dimensions 300 um dia 1 5 cm long 1 2 mm x 61 mm lead Contact Posts EL120 The EL120 Ag AgCl electrode has contact posts designed to improve contact through fur or hair Twelve posts create a 10 mm contact area The posts are 2 mm deep to push through fur hair to provide good contact with the skin sur face Requires LEAD120 page 36 Shipped 10 pack Micromanipulator MANIPULATOR This manual micromanipulator is a reliable durable and economical solution for high precision experiments Vernier scales allow readings to 0 1 mm X axis fine control allows readings to 10 m Includes a tilting base and ships with a standard 12 mm clamp and electrode holder 14 cm long All control knobs project to the rear so units can be tight ly grouped Specify
25. stroke volume Extract visual and auditory responses with signal averaging tools Use advanced integration features for pulmonary function studies Make metabolic studies easy with BSL software tools and the CO amp O Analysis Module GASSYS2 page 34 Calculate stroke volume and cardiac output with data from the Cardiac Output Sensor SS31L page 29 Select tools for spike sorting spike counting and automatic measurements Expanded menu with increased analysis tools Stimulator and other Output Control mm toolbars provide consistency and have intuitive controls and right click access to Preferences Plus you can save multiple Customization Customize menu and toolbar options to show or hide analysis and editing controls based on the lesson requirements stimulus paradigms within a file Customize the grid display easily create clinical ECG grids e Select the measurements that students must use to analyze the data Markers layer for printing to prevent overlap Automatic Add text to the Journal so students have online access to your instructions stimulus markers log pulse width and rate Establish marker options to predefine recording segments or allow Uma ER meu mas StUdeNTS to add comments to files pem ee Predefine segment marker text the marker describes each new recording segment sit up lay down Predefine event markers set function keys to mark and describe events segments in the experim
26. than 20 interface options page 39 for manufacturers like Grass Gilson Harvard and Vernier BIOPAC is continually adding and improving products and lessons Visit www biopac com for the latest additions 1 K e Packages are offered as a comprehensive building block for discipline specific applications e Increase application potential by adding more hardware BIOPAC Hardware Data Acquisition Unit amp Cables BSL Software Lessons amp PRO Lab Manual BSL lessons PRO Lessons 40 experiments Electrode Lead x2 High impedance Cable 1V Input x2 High impedance Cable 5V Input Electrodes Disposable 100 pk Abrasive Pads 10 pk Airflow Transducer Calibration Syringe 600ml Bacterial Filters Disposable 10 pk Mouthpieces Disposable 10 pk Nose Clips Disposable 10 pk Electrodermal Activity GSR Lead EDA GSR Electrodes 100 pk Hand Switch Pushbutton Headphones Pulse Plethysmograph Transducer Respiratory Effort Transducer Temperature Transducer Colored Paper for L09 Polygraph Electrode Gel Tape Single sided Blood Pressure Cuff Transducer Electronic Stethoscope Transducer Force Transducer Variable range Hand Dynamometer Multi Lead ECG Cable Pressure Transducer Stimulator BSL Stim Electrode human safe Stimulator Low Voltage Stim Electrode animal Dissolved O Probe Dissolved O Interface Signal Processing Breadboard Electrode Lead unshielded x2 Electrode Leads sh
27. the Occipital Lobe BSL10 Eye Movement Saccades amp Fixation H10 EEG amp Hemispheric Asymmetry H12 EOG Saccades amp Displacement H13 EOG Visual Tracking vs Imagination H14 Ocular Fixation while reading H15 Ocular Fixation while viewing an image Biomedical Engineering H20 BME Filtering H33 FFT Fast Fourier Transform See page 43 45 for a description of all available lessons Increase your lab options with Stimulator BSLSTMB p 25 Stim Electrode for humans HSTMO1 p 28 Finger Twitch Transducer SS61L p 30 0 amp CO Analysis Module GASSYS2 EA p 34 Dissolved 0 Probe RXPROBEO2 p 31 pH Probe RXPROBEO p 31 Reflex Hammer Transducer SS36L p 30 Multi Lead ECG Cable SS29L p 27 Cardiac Output Sensor SS31L p 29 Goniometer SS21L p 29 Respiratory Effort Trans SS5LB p 26 Temperature Trans SS6L p 26 Headphones OUT1A p 26 EDA GSR Lead SS57L p 26 SuperLab System STP35W p 32 Transducer Accessory Pack BSLHPY TA p 42 an ne physiology amp intro human phys Cardiovascular Hemodynamics Lessons cover ECG 1 12 lead and allow students to isolate components of the ECG complex and use the averaging features in the software for further ECG analysis Use the electronic stethoscope to examine heart sounds and then overlap the data to correlate the sounds with the mechanical and electrical events of the cardiac cycle Record arterial blood pressure and record systolic diastolic mean dP dt
28. 0 Filtering H14 Ocular Fixation while reading H33 FFT Fast Fourier Transform H15 Ocular Fixation while viewing an image advanced system These hardware suggestions will enable you to perform a variety of lessons for human subjects Use BIOPAC lessons or easily create your own experiments with the BSL PRO software included with each system Order the Advanced System or select items a la carte A hardware upgrade kit is available to upgrade to the Ultimate System See BSL Hardware page 23 for all available transducers electrodes and accessories Perform 33 or more lessons with the Advanced System Muscular BSL1 Standard amp Integrated EMG HO7 EMG Contractions Active Learning H27 Facial EMG H34 Electrogastrogram from human H36 Muscular Biofeedback Pulmonary Function BSL8 Respiratory Cycle BSL12 Pulmonary Function Vol amp Capacities BSL13 Pulmonary Flow Rates FEV and MVV BSL15 Aerobic Exercise Physiology Neurophysiology Cardiovascular BSL3 EEG Relaxation amp Brain Rhythms BSL5 Components of the ECG Lead Il BSL4 Alpha Rhythms in the Occipital Lobe BSL6 Leads Il Ill amp Einthoven s Law BSL9 GSR and Polygraph BSL7 ECG amp Pulse BSL10 EOG Eye Movement Saccades amp Fixation H05 WAnT Wingate Test BSL11 Reaction Time amp Learning H08 Dive Reflex Active Learning BSL14 Biofeedback Relaxation amp Arousal H23 Signal Averaged ECG H32 Heart Rate Variability ultimate system H10 H11 H12 H13 H14 H
29. 104A The RX104A replacement element for the SS13L Pressure Trans ducer does not include the Simple Sensor connector and cable See Lessons H04 pages 44 45 Blood Pressure Cuff Transducers SS1 SLA Jong MP36 MP35 SS19L for MP45 30 Mechanical gauge Onscreen gauge Measure blood pressure via oscillometric or auscultatory methods Use with the SS30L to record BP and Korotkoff sounds Includes adult cuff RX120D pump bulb and pressure sensor Additional cuff sizes available SS19LA requires BSL 3 7 5 or above software Cuff Circumference Width Length Pressure range RX120A 9 5 13 5 cm 5 2 cm 18 5 cm 20 mmHg to 300 mmHg RX120B 13 0 19 0 cm 75 cm 26 1 cm Manometer accuracy RX120C 18 4 26 7 cm 10 5 cm 34 2 cm 3 mmHg RX120D 25 4 40 6 cm 14 5 cm 54 0 cm RX120E 34 3 50 8 cm 176 cm 63 3 cm RX120F 40 6 66 0cm 21 0cm 82 5 cm See Lessons BSL16 H04 pages 43 44 p Hand Dynamometer SS25LA f Ss Use in isolation or combine with EMG recordings for in depth studies of muscular activity The lightweight ergonomically designed transducer provides direct readings in kilograms or pounds Use to measure grip force Range 0 90 kg Weight 323 kg Dimensions 1778 cm x 5 59 cm x 2 54 cm See Lesson BSL2 page 43 Clench Force Bulb Dynamometer SS56L Measure force on the basis of the proportionality of clench force to pressure in the bulb Select units of Kgl m 2 or psi Ships with MP45 HScS Systems
30. 13 Pulmonary Flow Rates FEV and MVV Neurophysiology BSL3 EEG Relaxation amp Brain Rhythms BSL4 Alpha Rhythms in the Occipital Lobe BSL10 EOG Eye Movement Saccades amp Fixation BSL11 Reaction Time H10 EEG amp Hemispheric Asymmetry H12 EOG Saccades amp Displacement H13 EOG Visual Tracking vs Imagination H14 Ocular Fixation while reading H15 Ocular Fixation while viewing an image H16 Reflexes amp Reaction Time Active Learning Bioengineering H02 Compartmental Modeling H20 BME Filtering H25 BME Signal Processing 8 modules H26 ECG R wave Detector H33 FFT Fast Fourier Transformation See page 42 44 for a description of all available lessons Increase your lab options with Cardiac Output Sensor SS31L p 29 0 amp CO Analysis Module GASSYS2 EA p 34 Finger Twitch Transducer SS61L p 30 Heel Toe Strike Transducer SS28LA p 29 Stimulator BSLSTMB p 25 Tri Axial Accelerometer SS26L p 29 Transducer Accessory Pack BSLBME TA p 42 22 T o C r gt E 3l lessons targeted for Pharmacology amp Toxicology ECG EEG EGG EOG amp EMG Temperature Tissue Bath Station with integrated heating circulator Stimulator direct or field Cardiac Output via bioimpedance Dose Response Studies Smooth Muscle Cardiac Muscle Skeletal Muscle Epithelial Transport lon Transport Ussing Chamber Measurements Gas Analysis Module Blood Pressure Isolated Heart Lung Isol
31. 15 H16 H24 EEG amp Hemispheric Asymmetry Mirror Test EDA Sensory motor learning EOG Saccades amp Displacement EOG Visual Tracking Ocular Fixation while reading Ocular Fixation while viewing an image Reaction Time Habituation Bioengineering H02 H20 H33 Compartmental Modeling Filtering FFT Fast Fourier Transform These hardware suggestions will enable you to perform a variety of lessons for human and animal subjects Use BIOPAC lessons or easily create your own experiments with the BSL PRO software included with each system Order the Ultimate System or select items la carte See BSL Hardware page 23 for all available transducers electrodes and accessories Perform 43 or more lessons with the Ultimate System Muscular H04 Blood Pressure Isometric or Straining A05 Visceral Smooth Muscle exercise BSL1 Standard amp Integrated EMG H05 WAnT Wingate Test BSL2 Motor Unit Recruitment amp Fatigue H08 Dive Reflex Active Learning HOG Finger Twitch H23 Signal Averaged ECG HO7 EMG Contractions Active Learning H32 Heart Rate Variability H27 Facial EMG H34 Electrogastrogram from human H36 Muscular Biofeedback Pulmonary Function BSL8 Respiratory Cycle BSL12 Pulmonary Function Vol amp Capacities BSL13 Pulmonary Flow Rates FEV and MVV BSL15 Aerobic Exercise Physiology Cardiovascular A04 Frog Heart BSL5 Components of the ECG Lead Il ro DN BSL6 Leads II Ill amp Einthoven s Law Neurophysio
32. 2 and BSL TCI16 Type Polarographic Oxygen Range 0 40 ppm Electrodes Platinum and silver Minimum sample velocity 20 cm sec See Lesson A07 page 45 Tubephone OUT101 Use the OUT101 with a stimulator module to deliver clicks in auditory The tubephone design consists of a 7 monaural acoustic transducer attached to a short flexible em tube which fits into the subject s ear with the aid of a foam tip Compares to TDH 39 49 or 50 audiometric headphones Includes 1 4 to s phono adapter Dimensions 3 8 cm wide x 5 cm high x 1 cm thick Cable termination 6 3 mm 1 4 phone plug Cable length 1 8 meter See Lesson H09 page 44 See the Headphones OUTIA on page 26 Tension Adjuster HDW100A Use the HDW100A to adjust the tension between the preparation and a Force transducer SS12LA on page 27 or SS63L SS66L on page 31 The position adjuster is located on the top for easy access and smooth operation and mounts on typical lab stands Vertical scales are provided for both metric and standard units Works with most commercial force transducers Travel Range 25 mm Resolution 0 0025 mm per degree rotation Stand Clamp 12 80 mm ID Transducer Clamp 14 60 mm ID Dimensions 93 mm high X 19 mm thick x 74 mm deep See Lessons A02 A04 A05 A09 A15 page 45 Tension Adjuster Adapter HDW200 This adapter allows third party tension adjusters with an arm diameter of 6 35 mm 7 4 or l
33. 20 E mail geelmed link net www algeeltrading com Israel Bargal Analytical Instruments Ltd Hagalil st POB 1019 Airport city Ben Gurion Airport 010000 Israel Tel 972 3 9796533 Fax 972 3 9796538 E mail sales bargal co il Web www bargal co il Saudi Arabia Raez Environmental Systems amp Advanced lechnologies RESAT Riyadh Kingdom of Saudi Arabia Tel 966 478 2295 Fax 966 474 0794 E mail info resat org Web www resat org AMERICAS Brazil Sellex Inc Rua Arandu 205 1105 04562 030 Sao Paulo SP Brazil Tel 011 5506 4646 Fax 011 5505 7433 E mail vendas sellex com Web www sellex com Canada BIOPAC Systems Canada Inc PO Box 8 Station Ahuntsic Montreal QC Canada H3L 3N5 Tel 450 621 4782 Toll Free in Canada 877 5 BIOPAC 877 524 6722 Fax 450 965 1735 E mail info biopac ca Web www biopac ca Chile Marova Los Pirineos 807 San Pedro de la Paz Concepcion Chile Tel 56 4 2748325 E mail laboratorio marova cl Columbia ANDITECNICA Andina de Tecnologias Ltda Calle 34 No 81 59 Barrio La Castellana Medellin Colombia Tel 57 4 4164040 E mail didactica anditecnica com Web www anditecnica com Mexico Bl Biotecnologia Quimica S A de C V Luis Gonz lez Obreg n No 16 Cronistas Ciudad Sat lite CP 53100 Naucalpan Edo De M xico Tel 52 55 5572 3009 Fax 452 55 5393 3019 E mail bioquim prodigy netmx Web www biotecnologiaquimica com mx Peru LAB SOLU
34. 27 Dissolved Oz Probe Interface BSL TCI16 p 39 Needle Electrodes x 3 EL452 p 38 EDA GSR Lead SS57L p 26 Nerve Chamber NERVE2 p 38 Perform 52 or more lessons with this core package Muscular H23 Signal Averaged ECG A02 Frog Gastrocnemius H32 Heart Rate Variability A05 Visceral Smooth Muscle l A11 Resting Potential from Crawdad Manual Pulmonary Function M5 Earthworm Smooth Muscle A07 Dissolved O goldfish with your probe BSL1 Standard amp Integrated EMG BSL8 Respiratory Cycle M BSL2 Motor Unit Recruitment amp Fatigue BSL12 Pulmonary Function Vol amp Capacities HOG Finger Twitch BSL13 Pulmonary Flow Rates FEV and MVV H07 EMG Contractions Active Learning BSL15 Aerobic Exercise Physiology H27 Facial EMG Neurophysiology H34 EGG Electrogastrogram A01 Frog Pith amp Prep H36 Muscular Biofeedback A03 Frog Nerve Cardiovascular A06 Cockroach Nerve A04 Frog Heart A08 Action Potential Earthworm BSL5 Components of the ECG Lead II 09 Turtle Heart BSL6 Leads I II Ill amp Einthoven s Law Al4 CPGHomwom BSL7 ECG amp Pulse BSL3 EEG Relaxation amp Brain Rhythms BSL16 Blood Pressure amp Korotkoff Sounds BSL4 Alpha Rhythms in the Occipital Lobe BSL17 Heart Sounds amp Cardiac Events BSL9 GSR and Polygraph Nw HO1 12 lead ECG BSL10 EOG Eye Movement Saccades amp Fixation H04 BP Response to Straining BSL11 Reaction Time H05 WAnT Wingate Test BSL14 Biofeedback Relaxation amp Arousal H08 Dive Reflex Active Learning H03 Nerve
35. 3 pA Noise Voltige 13V pp requiring a trigger or analog output Cable 1 2 meters signal See the BSL TCI series for existing transducer interfaces Nerve Seer Stimulation BSLCBLIA BNC to 2 x banana Use to connect the BSLSTM or SS58L transducer interface options stimulator to third party nerve chambers 1 2 meter cable Transducer Connector Interfaces BSL TCI SERIES BSLCBL2A BNC to 2 x 2 mm H 3 banana pin with ground jumper Use to connect the BSLSTM or SS58L stimulator to BIOPAC nerve chambers 1 2 meter cable interface cables 4 Save money and interface with your existing transducers BSL TCI Series connectors for common transducer manufacturers are listed Analog Input below if you don t see the part you need call BIOPAC Support BNC Input or use the SS KIT to build a custom interface Connect to an analog input port Part Connector Make Works with Transducers from CH1 CH4 on the MP unit to BSLTCIO 6 pin Grass and Gilson record signals from other devices such bea ESLT H Beerman H 5 i BSLTCI2 8 pin AD Instruments iWorx and WPI Transducers as amplifiers third party chart recorders and signal generators BSLTCI3 9 pin hexagonal Lafayette and Narco Safety Note Always use the SS70L when working with human BSLTCl4 6 pin seu i BSL TCI5 4 pin phone jac BIOPAC NIBP100D or NIBP100A BP module subjects Never use the SS9LA unisolated BNC input with human gs repe
36. 6mm 54mm 377 g Exercising Human Part 4 Head Max Range Dead Space Output IV ml sec Ports ID OD Length Weight d SS52L RX137H1 8 L sec 80 cc 0 0385 43 mm 4b mm 60mm 250 g Requires one coupler AFTI1F page 35 to interface with the GASSYS2 page 34 and other airflow accessories 34 airflow amp gas analysis EH Gas Analysis Module GASSYS2 a O and CO Gas Analysis Module measures expired O and CO concentra tions Obtain real time Oxygen Consumption VO Basal Metabolic Rate BMR and Respiratory Exchange Ratio RER measurements using the MP36 System with the GASSYS2 module Available with a 5 liter chamber or a 1 liter chamber for small children medium sized animals Chambers are modular so you can inter change them with one base module and they are easy to clean The GASSYS2 includes tubing AFT7 coupler AFT11E non rebreathing T valve AFT22 and a sep arate 12 V power supply AC100A creating a low cost solution for BSL users already using the SS11LA Airflow Transducer and accessories Flap valve prevents expired air from returning to chamber and gas calibration port allows O2 CO gt sensor calibration CO Range 0 5 O Range 0 25 Note Two couplers 2 x AFT11F required when interfacing with the Airflow Transducer SS52L GASSYS2 EA Module with 5 liter chamber GASSYS2 EB Module with 1 liter chamber RX GASA 5 liter chamber screw fixture RX GASB 1
37. AC Systems Inc 42 Aero Camino Goleta CA 93117 USA Tel 805 685 0066 Fax 805 685 0067 www biopac com info 9 biopac com U keeps getting be tter The Biopac Student Lab System is an integrated solution that includes hardware and software that students use to record data from their own bodies animals or tissue preparations Also includes 65 life science lesson experiments and easy instructions to modify them or integrate your existing syllabus The BSL is 1 in CLASS e Total of 65 lesson experiments e Comprehensive support from published Lab Manuals Marieb PEARSON Benjamin Cummings Fox WCB McGraw Hill Wood PEARSON Benjamin Cummings Pflanzer Kendall Hunt e Video demonstration clips e Online lessons e Distance learning e Suitable for 2 amp 4 year programs medical schools and nursing programs e Lesson development support from BIOPAC e Physiology animal and human e Exercise Physiology and Biomechanics e Psychophysiology and Neurophysiology e Pharmacology and Toxicology e Human Anatomy e Biology e Bioengineering e And more A 4 T 4 4 7 D O LITIA 11 Y A 1 C I CArnNniIino LAIU A C L CULI IELILL e New Gas Analysis lessons lanes as subjects e Inquiry based hypothesis driven lessons e Easy lesson customization for student experiment design e Application Notes for advanced experiment design BIOPAC STUDENT LAB Total Solutions with Total Support h En
38. Analysis amp Processing The BSL software has an extensive library of signal processing functions permitting graphical insight to analytical methods The software can demonstrate the procedure and consequences associated with simple to complex signal processing methodologies For example students can view data before and after IIR or FIR filter processing build a complex waveform from periodic signals i e create a square wave from multiple sine waves and decompose the BME Square result or apply non linear processing methods to data Use the X Y display mode to generate Lissajous patterns and investigate chaotic phenomena and demonstrate phase relationships between two variables Signals can be correlated and convolved Use the histogram function to focus on distribu 35HzLPN 6OHz Filter Hz st nee tion of specific signal measures Transducers amp Calibration The BSL System employs a wide array of transducers that transform physical measures into electrical signals The generic input design FFT of Biopotential filter of the MP36 acquisition unit allows it to inter d OA face a huge variety of third party or completely unique transducers Students can use the BSL software to linearize and calibrate transducers and then compare results to expected values Relate fundamental physical standards to more complicated measures For example calibrate the Airflow Transducer with a syringe and then use the Airfl
39. BSL LESSON 12 PULMONARY FUNCTION I Perform a variety of pulmonary measurements Tidal volume Inspiratory capacity Expiratory capacity Functional residual capacity Vital capacity and Total lung capacity BSL LESSON 13 PULMONARY FUNCTION II Record and analyze Forced Vital Capacity Forced Expiratory Volume FEVi 2 3 and Maximal Voluntary Ventilation MVV to build on the principles established in Lesson 12 H29 BASAL METABOLIC RATE Record indirect basal metabolic rate BMR and post exercise metabolic rate H19 VO amp RER Record and measure oxygen consumption absolute VO and respiratory exchange ratio RER under a variety of conditions and observe the relationship between VO and RER ecm 24 Record maximum grip clench for NEUROPHYSIOLOGY Sete Steet the dominant and non dominant BSL LESSON 3 FEG I f hand to investigate the properties of skeletal muscle BSL LESSON 2 EMG II Use a hand dynamometer to record maximum grip strength for both hands and explore the role of skeletal mus cle in performing mechanical tasks H06 FINGER TWITCH HUMAN Record the force generated from a finger twitch and measure the stimulus frequency required to induce fatigue Alternative to Frog Gastroc Record EEG from the occipital lobe while performing a variety of tasks to demonstrate how the brain s electrical activity varies dependent upon the task being performed BSL LESSON 4 EEG II Discover how the brain constantl
40. Conduction ulnar nerve pH Probe Interface BSL TCI21 p 39 Pressure Transducer SS13L p 27 Pulse Transducer SS4LA p 26 Recording Nerve Cable BSLCBL4B p 39 Respiratory Effort Transducer SS5LB p 26 Stimulator BSLSTMB p 25 Stim Electrode for humans HSTMO I p 28 Stim Electrode for animals ELSTM2 p 38 Stimulator Nerve Cable BSLCBL2A p 39 Surgical Tape TAPE1 p 36 Temperature Transducer SS6L p 26 H10 EEG amp Hemispheric Asymmetry H11 Mirror Test EDA Sensory motor learning H12 EOG Saccades amp Displacement H13 EOG Visual Tracking vs Imagination H14 Ocular Fixation while reading H15 Ocular Fixation while viewing an image H16 Reflexes amp Reaction Time Active Learning H24 Habituation Biomedical Engineering H02 H20 amp H33 See page 43 45 for a description of all available lessons Increase your lab options with Cardiac Output Sensor SS31L p 29 Dissolved 02 Probe RXPROBEO2 p 31 Finger Twitch Transducer SS61L p 30 0 amp CO Analysis Module GASSYS2 EA p 34 pH Probe RXPROBEO p 31 Reflex Hammer Transducer SS36L p 30 LI 27 lessons targeted for Exercise Phys amp Biomechanics ECG EEG EMG EOG amp EGG Respiration 16 Temperature Airflow amp Lung Volume Gas Analysis CO amp O2 Metabolic Cart Cardiac Output via bioimpedance Respiratory Exchange Ratio Basal or Resting Metabolic Rate Motor Unit Recruitment 2 Lead ECG Heart Sounds Blood Pressure
41. Cosumnes River College Cuesta College Dartmouth College Diablo Valley College Dixie College Duke University Eastern Oregon University Elizabethtown College Emory University Everett Community College Evergreen State College Florida International University Florida State University Georgia College amp State Univ Georgia Institute of Technology Georgia State University Golden West College Gordon College Harvard University Hofstra University Imperial Valley College Indiana State University Indiana Univ Purdue Univ lowa State University Ithaca College Ivy Tech State College Jacksonville State University Jefferson Community College Johns Hopkins Medical School Kent State University LA Mission College Lake Superior College Ethiopian Health and Nutrition Research Institute FH Dortmund FH Joanneum Graz FH M nchen Facult Polytechnique de Mons Facult s Universitaires Notre Dame de la Paix Fu Jen Catholic University Gaziantep University Hacettepe University Hanlim University Hiroshima Shudo University H gskolan i J nk ping INSERM Inter American University of Puerto Rico International Islamic University Istanbul University Johann Wolfgang Goethe Universitat Frankfurt am Main Kakitaya University Khon Kaen University King Saud University King s University College Kirikkale University Klaipeda University Kobe Gakuin University Lady Harding Medical College Leeds Metropolitan
42. DA GSR Transducer SS3LA on page 28 as an alternative reusable option Range 1 100 uMho normal human range is 1 20 uMho Excitation 0 5 V DC constant Pinch Leads Red Black GND See Lessons BSL9 BSL14 H11 H24 page 44 Pulse Photoplethysmogram SS4LA Measure blood density changes in the fingertip or other body locations caused by varying blood pressure Record the pulse pressure waveform Attach to the finger by the Velcro strap or tape to other body parts Sensor type IR Dimensions 16 mm long x 17 mm wide x 8 mm high See Lessons BSL7 H05 pages 43 44 Respiratory Effort Transducer SS5LB Record respiration via chest or abdominal expansion and contraction The strap presents minimal resistance to movement and is extremely unobtrusive The novel non Piezo design permits the recording of arbitrarily slow respiratory activity Response True DC Circumference Range 10 cm 140 cm increase with a longer nylon strap Dimensions 95 mm long x 47 mm wide x 15 mm thick See Lessons BSL8 BSL9 pages 43 44 Fast response Thermistor SS6L Measure small variations in temperature either on the skin surface or in an air stream Record temperature changes in airflow during breathing to indicate respiration rate Attach to the skin surface with surgical tape TAPE1 Response time 0 6 sec Compatibility YSI series 400 Max operating temp 100 C Dimensions 5 m long x 1 7 m diameter Accura
43. EOG e Blood Pressure e Gas Analysis e Metabolic Rate Engage students with dynamic lessons as they record data from their own bodies e New Budget Beating packages e Customize lessons from BIOPAC s extensive Curriculum Library e Incorporate clinical techniques in the lab Students learn real world skills Combine physiological data with stimulus presentation Analog Digital and Calculation channels No complicated knobs or dials the gold standard for Since its introduction in 1995 the Biopac Student Lab has evolved based on input from many thousands of existing users and physiology instructors To see for your self why the BSL offers the most meaningful flexible lab experience for students and teachers visit www biopac com and check out demo video clips and sample lessons Give your students a proven advantage give them the Biopac Student Lab BSL 4 Major Upgrade Dynamic user interface improves lab experience Students can prepare for the lab by downloading free BSL Analysis software that allows them to review the lesson physiology introduction and recording procedures and play with the software Lesson videos are included in the software and also on the BIOPAC YouTube channel to help students prepare and understand what they will be doing Students work in groups of 3 to 6 Students are assigned roles Subject Recorder and Director Because of BSL s ease of use students can rotate through the ro
44. GAS SYSTEM2 page 34 Bioimpedance Strip Electrodes EL506 10 80 pk page 37 Biomechanics TA BSLEXM TA This hardware Reflex Hammer Transducer SS36L page 30 Goniometer Twin axis SS21L page 29 Stimulator BSLSTMB page 25 Stimulation Electrode for Humans HSTMOI page 28 Heel Toe Strike Transducer SS28LA page 29 Psychophysiology TA BSLPSY TA This hardware Cardiac Output Sensor SS31L page 29 SuperLab Stimulus Presentation Pkg STP35W page 32 Bioimpedance Strip Electrodes EL506 10 80 pk page 37 Biomedical Engineering TA BSLBME TA This hardware Cardiac Output Sensor SS31L page 29 Stimulator BSLSTMB page 25 Stimulation Electrode for Humans HSTMOI page 28 Bioimpedance Strip Electrodes EL506 10 80 pk page 37 Pharmacology amp Toxicology TA BSLPHA TA This hardware Tissue Bath Station ITBS100 page 33 See Core Human Phys on page 11 Adds these lessons BSL20 Spinal Cord Reflexes page 44 H03 Nerve Conduction Velocity page 44 H06 Finger Twitch page 43 H28 Reflex Response patellar tendon page 44 See Core Animal Phys on page 13 Add this lesson H21 Impedance Cardiography CO page 43 See Core Exercise Phys on page 17 Adds these lessons H21 Impedance Cardiography CO page 43 H29 Basal Metabolic Rate page 43 HO1 12 lead ECG page 43 H19 VO2 amp RER page 43 See Core Exercise Phys on page 17 Adds these lessons BSL20 Spinal Cord Reflexes page 44 H03 Nerve Condu
45. In Vitro SS13L 27 NIBP200A 33 Cuff Trans SSI9LA L 27 Noninvasive Monitoring NIBP I OOD 32 See also Sound Detection Breadboard Signal Processing SS39L 30 BSL Biopac Student Lab Overview 2 7 Cables High impedance BSLCBL8 9 36 Interface 39 Nerve Recording BSLCBL3A 4B 39 Nerve Stimulating BSLCBL A 2A 39 USB CBLUSB 40 Cardiac Output Sensor SS31L 29 Consumables AFT series 34 Conversion Mac PC PLAT30 series 40 Core Packages 8 23 41 Customer Loyalty Program Upgrades contact BIOPAC Data Acquisition Unit MP36 24 Differential Pressure Trans SS40L SS42L 30 Displacement Trans SS14L 28 Dissolved O Probe Trans SS69L 31 Electrodes 36 38 Accessories Gel lape Abrasive Pads 36 Adhesive Disks Collars ADD200 36 Bar Electrode Series EL350 37 Disposable Series EL500 37 Leads Clip Leads Recording LEAD 140 141 142 36 Clip Leads Stimulation BSLCBL7 I 1 12 38 Multi lead 12 lead ECG Cable SS29L 27 Pinch Leads LEAD IO series 36 Shielded Adapter SSILA 36 Shielded General purpose Lead Set SS2LB 25 Needle series EDU SC Reusable Series EL250 37 Stimulating for animals ELSTM2 38 Stimulating human safe HSTMOI 28 EDA GSR Electrodermal Activity Disposable Setup 5557L 26 Reusable Trans SS3LA 28 Electrodes with Isotonic Gel EL507 37 Exercise Physiology 16 Finger Twitch Trans SS6 IL 30 Force Fixed range Trans SS63L SS66L 31 Hand Dynamometer SS25LA 27 Tension Adjuster HDW 100A 31 Variable Ra
46. Le n Universidad de Navarra Universidad de Oviedo Universidad de Puerto Rico Cayey Universidad de San Carlos de Guatemala niversidad de Zaragoza niversidad del Pa s Vasco niversidad Nacional Aut noma de Mexico Universidad Nacional de Mar del Plata Universidade Agostinho Neto Universidade da Coru a Universidade de Lisboa U U eS niversidade do Porto niversidade Federal do Espirito Santo niversitas Andalas niversitas Katolik Widya Mandala Surabaya niversitat Aut noma de Barcelona niversitat de Barcelona niversitat de les Illes Balears niversitat de Val ncia niversitat Freiburg niversit t Graz niversitat Linz niversitat Mainz niversitat T bingen niversit Bordeaux 2 niversit de Bretagne Occidentale niversit de Gen ve niversit de Metz niversit de Moncton niversit de Savoie Gres G U U U U U U U U U U U U U U University of Memphis University of Michigan University of Minnesota University of Mississippi University of Missouri University of Montana University of Nebraska University of New England University of New Orleans University of North Carolina Chapel Hill University of North Texas University of Oklahoma University of Pennsylvania University of Pittsburgh University of San Francisco University of South Alabama University of South Carolina Aiken Columbia Spartanburg University of Texas University of Utah University of Vermont University of Virginia Univ
47. Long term Electrodes EL502 Moisture resistant backing solid gel adheres well to skin 41 mm diameter tape 10 mm contact area EL502 50 pack EL502 10 500 pack Cloth Base Electrodes EL504 Use these compliant trimmable and flexible elec trodes in difficult locations such as the face for EMG or fingers for nerve conduction 2 5 cm squares EL504 30 pack EL504 10 300 pack _ See Lessons H27 H31 page 43 44 amp i Bioimpedance Strip Electrodes EL506 25 cm trimmable Ag AgCl replace band electrodes Use with the noninvasive Cardiac Output Sensor SS31L page 29 EL506 8 pack EL506 10 80 pack See Lesson H21 page 43 JU dL Ag AOQ dh A AN PAM P Y AN EDA GSR Electrodes EL507 Use with the EDA Lead SS57L page 26 for skin conductance and resistance setups Electrodes have an increased contact area and isotonic wet gel EL507 100 pack EL507 10 1 000 pack See Lesson BSL9 BSL14 H11 H24 page 44 lectr Ag AgCl Electrodes EL250 Series Silver silver chloride reusable elec trodes Use EL250 series electrodes as an alternative to the SS2LB and EL500 series disposable electrodes Typically for one biopotential input you will need two shielded electrodes for signal inputs and one unshielded electrode for ground The 1 meter leads terminate in Touchproof 1 5 mm socket connectors for direct connection to the SS1LA BSLCBL8 or BSLCBL9 lead adapters page 36 All EL250 Seri
48. N TIME Measure basic reflex and reaction time visual stimulus exercises and record reaction time to auditory stimulus Compare reaction times from fixed interval and pseudo random presentation to study the effects of learning and physiological processes on reaction times H22 VISUAL EVOKED RESPONSE Present a visual stimulus to a human subject and record Visual Evoked Potentials P100 test H24 HABITUATION Record EDA GSR and Heart Rate response to repeated stim ulus to demonstrate habituation and its probabilistic trend toward decreased response H28 REFLEX RESPONSE Record knee and ankle reflex response with the SS36L Reflex Hammer transducer Option Use the SS20L Goniometer to measure angular movement in response to varying strike force H30 STROOP EFFECT Record strength of interference between two associative tasks naming and reading H31 PREPULSE INHIBITION Record the startle response with and without a prepulse inhibition stimulus H32 HEART RATE VARIABILITY Explore statistical measures geometric measures and spectral analysis in heart rate variability EXERCISE PHYSIOLOGY BSL LESSON 15 AEROBIC EXERCISE PHYSIOLOGY Record ECG heart rate airflow and skin temperature as the body responds to changing metabolic demands BSL LESSON 20 SPINAL CORD REFLEXES Record and examine properties of spinal neuromuscular reflexes commonly tested in physical diagnosis H04 BLOOD PRESSURE Record noninvasiv
49. Qv PRINCIPLE Dissolved O Goldfish Demonstrate the Qio principle by measuring the metabolic rate of goldfish at two temperatures 22 C acclimation temperature and 32 C acute exposure temperature A08 ACTION POTENTIALS IN EARTHWORM Use extracellular recording techniques to stimulate and record action potentials from an earthworm s nerve cord Measure conduction velocity and refractory period and plot a strength versus duration curve A09 PROPERTIES OF CARDIAC MUSCLE Turtle Heart Measure the duration of systole and diastole and observe the effects of diastolic loading Monitor the effect of vagal stimu lation temperature changes and spontaneous rhythmicity of the heart All RESTING POTENTIAL Crayfish Muscle Follow BSL setup and use Lab 4 Crayfish Muscle Resting Potential from the Crawdad CD ROM Lab Manual for Neurophysiology ISBN 0 87893 947 4 to record and alter resting potential by changing external ion concentration Al4 CENTRAL PATTERN GENERATORS Perform extracellular recording on tobacco hornworm pupae to study central pattern generators CPGs and neural mechanisms A15 EARTHWORM SMOOTH MUSCLE Setup earthworm gut with a force transducer and tissue bath to measure contractions and the effect of drugs Al7 FROG HEART INTRACELLULAR ACTION POTENTIAL Examine electrical properties of myocardial cells in the vertebrate heart and study the effects of pharmacological probes on the cardiac action
50. SS60L p30 SS2LB x2 p25 SSIOL p26 SS2LB p25 SS36L p30 SS20L p29 SSI ILA p27 GASSYS2 and AFT6A p34 SSIOL p26 STP35W p32 SS2LB p25 STP35W p32 OUT100 web SS2LB p25 no transducers required SS2LB p25 SS2IL p29 SS2LB p25 OUTIA 40HP p26 no transducers required SSI2LA p27 STIM p25 ELSTM2 p38 STIM p25 NERVEI 2 p38 BSLCBL p39 SSI2LA p27 HDW p31 SSI2LA p27 HDW p31 ITBS100 p33 BSLCBL8 9 p36 EL452 x3 p38 SS69L p31 or BSL TCII6 p39 STIM p25 NERVEI 2 p38 BSLCBL p39 SS12LA p27 STIM p25 STM2 452 p38 CBL8 p36 BSLCBL8 p36 CBL204 x2 p39 BSLCBL8 p36 EL452 x3 p38 SSI2LA p27 HDW p31 ITBS100 p33 no ECG index Advanced System 9 Airflow amp Respiration Accessories Mouthpieces Nose Clips Filters Student Consumables BSL ACCPACK 34 So IEA Accessories 3 High Performance Accessories 35 Calibration Syringe 600 ml AFT6A 34 2 liter AFT26 35 Couplers AFTI series 35 Differential Pressure Trans SS40L SS42L 30 Facemask with T valve AFT25 35 Pneumogram Trans sm animal SS67L 31 Pneumotach Trans medium flow SSI ILA 27 Pneumotach Trans Series wide flow range Stolk 35 Tubing AF T7 35 T valve AFT21 35 Animal Physiology 12 Basic System 8 Bioimpedance Cardiac Output Sensor SS3 IL 29 Biology 14 Biomechanics 16 Biomedical Engineering BME 20 Biopac Student Lab Overview 2 7 Biopotential Electrodes 36 38 For ECG EDA GSR EEG EGG EMG EOG Blood Pressure Animal or
51. Student Lab File Name BIOPAC_H02_ File Edit Display Lessons Help Overlap Split 2 pet 784deare 3 Max 445 089 degre ESSE LESE s es es difference and then effect a change to observe a particular response Investigate linear and nonlinear control paradigms Create simple to intricate feedback loops where students perform a specific role in the loop operation For instance students can explore Westheimer s saccadic eye movement model which represents the eye as a 2nd order system then record eye motion via EOG set up and then erue ECC compare the real results to the modeled results to validate 4 7 or adjust the model Compartmental Modeling EOG Biomechanics The Student Lab System has a comprehensive ability to monitor gait and other mechanical responses The system works with Goniometers Accelerometers Heel Toe amp C Documents and Settings Joce xir ie 17500 sec Mass Spring Response sia Strike transducers and Tri Axial Accelerometers Biopotential signals such as EMG can be synchronously recorded Use the Hand Dynamometer and Tri Axial Accelerometer to measure isotonic and isometric performance Goniometers are available for evaluating one or two degrees of freedom from the same joint e g wrist flexion extension and radial ulnar deviations 7 00 7 40 7 80 seconds E Mes Use the X Y display mode to monitor motion resul
52. TION PERU SRL Calle San Rafael N 328 Urbanizaci n Los Angeles Arequipa Peru Tel 51 54 243131 Mobile 51 965 996 555 E mail ventas lsperu gmail com Bi Full translation available software and Lab Manual Software translation available Ask your local rep for details The ultimate teaching solution for Physiology Exercise Physiology amp Biomechanics Biology Psychophys amp Neurophysiology Biomedical Engineering Pharmacology amp Toxicology Nursing Veterinary Programs When you get the BSL they ll get science Incorporate clinical techniques amp industry standard equipment to teach your students real world skills ECG Biofeedback Nerve Conduction EEG Bioimpedance Pulmonary Function EMG Cardiac Output Reaction Time EOG BP amp Heart Sounds Respiration EDA GSR Metabolic Rate Temperature Multi level learning solutions let you control the material and method of each experiment e Inquiry based student lessons PRO Lessons Instructor modified labs Custom Lessons Advanced analysis tools No programming required Use for introductory lessons graduate programs or advanced research New hardware includes Low Voltage Stimulator Airflow Transducers wide flow range Cardiac Output Sensor Pneumogram Transducer Tissue Bath Stations Signal Processing Breadboard Nerve Chambers Variable Response Indicator CO amp Or Analysis Module Speech Freq Microphone Finger Twitch
53. Transducer Dissolved O2 Probe ae rE x Differential Pressure Trans Isolated BNC Input Adapter GE CE gm ispla Scar TEEEEEEEE z wtrant mm Dominent Arm Continued Cleach Preperetion Complete Solutions for Life Science Education BIOPAC wy Systems Inc Registered to ISO 9001 2008 42 Aero Camino Goleta CA 93117
54. University Link pings Universitet Ludwig Maximilians Universitat Munchen Ludwik Rydygier Medical University Max Planck Institute McGill University Mid Sweden University Nanyan Technological University National Taipei Nursing College National Taiwan University National Technical University of Athens Lehigh University Lenoir Rhyne College Life Chiropractic College West Linfield College Loma Linda University Louisiana State University Louisiana Tech University Loyola College Millsaps College Mississippi Valley State Univ Monterey Peninsula College Mount Holyoke College Mount Vernon Nazarene Coll Nassau Community College National Institutes of Health New York Medical College Ohio State Ohio University Oregon Institute of Technology Parker College of Chiropractic Pasadena City College Pierce College California Pierce College Washington Pima Community College Purdue University Quinnipiac College Rice University Rochester Institute of Technology Rollins College Rutgers University Sacred Heart University San Diego State University National Tsing Hua University National University of Singapore National Yang Ming University Netaji Subhas Institute of Technology NgeeAnn Polytechnic Niigata Sangyo University Nizams Institute of Medical Sciences Northumbria University Obirin University Osmangazi University Pingtung Technology University PSG Institute of Medical Scienc
55. Voltage Stimulator SS58L Use SS58L with MP35 units for low voltage stimulation MP36 systems have a built in low voltage stimulator and do not require the SS58L see OUT3 BNC adapter above 2 Use the Low Voltage Stimulator with any elec ao X trode or lead with a BNC connector such as nee dle electrodes or clip leads page 38 for direct SS58 stimulation of animal or tissue preps Interface H m nerve chambers via BSLCBL3A or BSLCBL4B page 39 Use with headphones or speakers for sound output Control the stimulus with the Output Control option of the BSL PRO software You can monitor the output directly on the computer without any external cable SS58L Specifications Interface MP35 Analog Out port unisolated Pulse level 10 V to 10 V software adjustable in 5 mV increments 25 Pulse width 0 05 100 milliseconds Pulse repetition 5 seconds 0 1 millisecond 0 2 10 000 Hz Power No aditional power required See Lessons A02 A05 A08 A09 page 45 Additional Output Options OUTIA Headphones page 26 HSTMOI Stim Electrode for humans page 28 TSD122C Stroboscope page 32 STP35W Stimulus Presentation System page 32 ELSTM2 Stim Electrodes page 38 BSLCBL7 11 12 Clip Leads page 38 Connect directly to the MP36 Data Acquisition Unit EDA Lead Transducer for Disposable Setups SS57L The SS57L EDA Lead Transducer snaps to two disposable EDA isotonic gel electrodes EL507 on page 37 See the E
56. X KR KR KR KX KM X x KKK KK KR MK x KX KK KK OX Psych x KK OX OX x x x x x KKK Nox OX x x x x x x x x Ex Phys x Ke KM OX x x x KX ON Ox X BME x mK KR OX X X x Ke KM OX x x x Ea x E NOX OX x Mm KX ON X X uw T a E SE a t X X X X X X X x x x X X X X x x x x X X X X X X X X x X x x x X x x x X X X X X X xt X xt glass microelectrode required HScS MP45 x KK KK X xe x wm KK X Hardware Used optional SS2LB p25 OUTIA 40HP p26 SS2LB p25 SS25LA p27 OUTIA 40HP p26 SS2LB p25 SS2LB p25 SS2LB p25 SS2LB x2 p25 SS2LB p25 SS4LA p26 SSSLB and SS6L p26 SS2LB p25 SSSLB and SS57L p26 SS2LB x2 p25 SSIOL and OUTIA p26 SSI ILA p27 AFT6A p34 SSI ILA p27 AFT6A p34 SS2LB p25 SS57L p26 SS2LB p25 SS6L p26 SSI ILA p27 SS2LB p25 SSI9LA L p27 SS30L p28 SS2LB p25 SS30L p28 SS2LB p25 SS36L p30 SS20L p29 SS29L p27 SS2LB p25 SS2LB p25 BSLSTMB p25 HSTMO1 p28 SSI9LA L p27 SS30L p28 SS4LA p26 SS61L p30 BSLSTMB p25 HSTMOI p28 SS2LB p25 SS2LB p25 BSLSTMB p25 OUTIOI p31 BSLCBL6 p38 SS2LB x2 p25 SSIOL and SS57L p26 SS2LB p25 SS2LB p25 SS2LB p25 SS2LB x2 p25 SSIOL and OUTIA p26 SS2LB x2 p25 SS2IL p29 NIBPIO0D p32 SSI ILA p27 GASSYS2 and AFT6A p34 no transducers required SS2LB p25 SS30L p28 SS3IL p29 SS2LB p25 TSD122 p32 SS2LB p25 SS2LB p25 SSIOL and SS57L p26 SS39L and SS60L p30 SS39L and
57. a telescopic endblock that compensates for changes in distance between the two mounting points as the limb moves Goniometers can be attached to the body surface using tape TAPE or TAPE2 page 36 Twin axis goniometers SS20L 21L are dual output devices and measure angular rotation about two orthogonal planes simultaneously e g wrist flexion extension and radial ulnar deviations Torsiometers SS22L 23L measure angular twisting as on the torso spine or neck as opposed to bending and measure rotation about a single axis e g forearm pronation supination The single axis goniometer SS24L measures finger thumb or toe joint movement and will measure the angle in one plane only SS20L SS21L SS22L SS23L SS24L Type Goniometer Goniometer Torsiometer Torsiometer Goniometer Channels 2 2 1 1 1 Max Length 110 mm 150 mm 110 mm 170 mm 3b mm Min Length 75mm 130 mm 75mm 150 mm 30 mm Range 150 150 150 150 150 Typical Placement wrist or ankle elbow knee neck torso or spine fingers thumb or shoulder or toes Weight 23 g 2b g 22g 23g 8g See Lessons BSL20 H17 H28 H35 pages 44 45 Accelerometers These tri axial accelerometers measure accelerations in the X Y and Z directions For simultaneous measurement three input channels are required The design conforms to body contours and includes a Velcro strap for easy attachment SS26LB Optimal for measuring slow movements such as walking SS27L Op
58. able Perform 31 or more Muscular A02 A05 A11 A15 BSL1 H07 H27 H34 Cardiovascular A04 A09 BSL5 BSL6 H08 H23 H32 Pulmonary Function A07 Neurophysiology A01 H15 BSLCBL2A p 39 lessons with this core package Frog Gastrocnemius Visceral Smooth Muscle Resting Potential from Crawdad Manual Earthworm Smooth Muscle Standard amp Integrated EMG EMG Contractions Active Learning Facial EMG EGG Electrogastrogram Frog Heart Turtle Heart Components of the ECG Lead Il Leads ll Ill amp Einthoven s Law Dive Reflex Active Learning Signal Averaged ECG Heart Rate Variability Dissolved O2 goldfish with your probe Frog Pith amp Prep Frog Nerve Cockroach Nerve Action Potential CPG Hornworm EEG Relaxation amp Brain Rhythms Alpha Rhythms in the Occipital Lobe Eye Movement Saccades amp Fixation EEG amp Hemispheric Asymmetry EOG Saccades amp Displacement EOG Visual Tracking vs Imagination Ocular Fixation while reading Ocular Fixation while viewing an image Biomedical Engineering H20 H33 BME Filtering FFT Fast Fourier Transform See page 43 45 for a description of all available lessons Increase your lab options with Cardiac Output Sensor Dissolved 0 Probe pH Probe SS31L p 29 RXPROBEO2 p 31 RXPROBE01 p 31 0 amp CO Analysis Module GASSYS2 EA p 34 Tissue Bath Station ITBS100 p 33 Temperature Transducer SS6L p 26 Transducer Ac
59. amp Interchangeability 0 2 C Compatibility YSI series 400 Compatibility YSI series 400 Dimensions 3 mm dia x 9 8 mm long Dimensions 4 mm dia X 115 mm long See the Fast response Thermistor SS6L on page 26 Displacement Transducer SS14L Record very slight movements up to 100 mm in a range of physiological preparations Incorporates a semi isotonic strain gauge 500 ohm silicon and a nickel plated cantilever beam device 27 cm for holding the transducer Features high linearity Sensitivity range Up to 100 mm Dimensions mm Body 95 x 25 x 25 Blade 305 x 1 27 x 0 6 Support rod 127 x 9 5 dia Physiological Sounds Microphone SS17L x oz Use to record a variety of acoustical signals including heart sounds and sounds associated with rubbing or Dives sen T grinding e g Bruxism Use with the SSI9LA L noninvasive Blood Pressure Cuff to record Korotkoff M eo n sounds for easy determination of systolic and diastolic blood pressure Use as a higher bandwidth alternative to the electronic stethoscope SS30L above Skin Microphone Bandwidth 35 Hz to 3 500 Hz Housing Stainless Steel Transducer Weight 9 grams See Lesson H04 page 44 See also Speech Frequency Microphone SS62L page 30 Goniometers amp Torsiometers SS20L SS24L Goniometers measure bending strain along or around a particular axis to transform angular position into a proportional electrical signal All goniometers have
60. ample programs available for C C C LabVIEW MATLAB and VB NET BIOPAC File Format API ACKAPI Use the base functions of this software library in a variety of combinations to use and parse specif ic data from BIOPAC s binary file format in other analysis programs Retrieval options include channel information samples by segment of a specified channel all samples of a specified channel a particular sample of a specified channel samples by time slice of a specified channel marker information text of a specified marker e Designed to be compatible with Microsoft C and Microsoft Visual Basic Specifications Analog Inputs Front panel DSUB 9f labeled CH Number of Channels Isolated human safe universal input amplifiers MP36 4 Channels MP45 2 Channels A D sampling resolution MP36 24 bit MP45 16 bit Gain Ranges 5x to 50 000x 13 steps Input Voltage Range Adjustable from 200 uVolts to 2 Volts MP36 10 V with SS70L page 39 Signal to Noise Ratio MP36 89 dB min MP45 75 dB min CMRR 85 dB minimum Filters Programmable analog and digital IIR filters automatic or user adjustable Analog Output i gt 1 V output Headphone Jack 3 5 mm stereo jack connection Sample Rate MP36 100k samples sec each channel MP45 48k samples sec each channel Serial Interface Type USB Certification Complies with IEC60601 1 EMC complies with IEC60601 1 2 CE Marked Dimensions Weight MP36 7 cm x 29 cm x 25cm 1 4 kg
61. ance Our area rep took the time to come down to see us and has been helpful with questions Dain LaRoche Johnson State College Environmental and Health Sciences Biopac Student Lab PRO C Do its lani xl add angle of limb movement as a subject performs a vari HEEEmESEUNGN zs awaa OEEC ety of tasks The system has transducers for recording heel and toe strike and acceleration for gait analysis stud ies Use the Hand Dynamometer and Tri Axial Accelerometer to measure isotonic and isometric per formance Goniometers are available for evaluating one or two degrees of freedom from the same joint e g wrist flexion extension and radial ulnar deviations Record Sit 4 Ready Grid Off Chart Disk amp Reach tests and analyze range of motion Use the X Y l Goniometry data display mode to monitor motion resulting from two degrees of freedom The BSL software will determine velocity of motion and calculate acceleration Nerve Conduction Combine the human safe stimulating electrode with the stimulator to record nerve conduction experiments Stimulate the ulnar nerve and record nerve conduction time Lesson H03 The procedure allows students to stimulate a subject at three different points along the ulnar nerve The distance between the stimulation and recording points is measured and the velocity of signal propagation along the nerve is calculated Muscular Students can measure EMG and Integrated EMG
62. ary to run a specified number of lessons specific to that particular discipline BASIC ADVANCED and ULTIMATE Systems MP36 have been offered since the Biopac Student Lab was launched in 1995 and are now in use in thousands of labs worldwide CORE packages MP36 are offered to meet the diverging requirements of specific departments INTRO and HScS Health Sciences Systems MP45 provide a H budget beating physiology lab solution Any package can be used as a starting point to develop your own custom system Please contact a Biopac Student Lab Specialist to request a formal quotation and to learn more about our quantity discounts If you 23 prefer you can build a quote online at www biopac com BSL Hardware Data Acquisition Unit page 24 Stimulators page 25 Transducers SS Series page 26 31 Stimulus Presentation page 32 Noninvasive Blood Pressure page 32 Tissue Bath Stations page 33 Airflow amp Gas Analysis page 33 35 Electrodes page 36 38 Interface Options page 39 Core Package Summary page 41 IMPORTANT USAGE NOTICE BIOPAC Systems Inc instruments components and accessories are designed for educational and research oriented life science applications and investigations BIOPAC Systems Inc does not condone the use of its instruments for clinical medical applications Instruments components and accessories provided by BIOPAC Systems Inc are not intended for the diagnosis cure mitigation treatment or preve
63. ated Muscle Nerve Activity Suitable for inquiry based active learning in 2 yr amp 4 yr programs medical schools and nursing programs onarmacology gs pm Respiratory amp Pulmonary Function The BSL lessons include measurements of Q Diopac Student Lab PROS CAD ES Transform Display Window MP35 Help ja x tidal volume inspiratory capacity expiratory capacity functional residual capacity vital capacity total lung capacity forced expiratory volume and maximal voluntary ventilation The new Gas Analysis Module provides a powerful tool for metabolic studies Measure expired O2 and CO with lessons for VO max respiratory exchange ratio and basal or Ready Grid Off Chart Ir ory Rabbit pulmonary function resting metabolic rate Perform metabolic respiratory and pulmonary measurements on a variety of species Cardiovascular Hemodynamics Lessons cover ECG 1 through 12 lead cardiac output and continuous blood pressure A heart sounds lesson allows students to listen to and record heart sounds while comparing them to the Frog heart rate response to ECG complex The frog heart lesson drugs explores cardiac rate and contractile response using a range of drug doses Students can analyze blood pressure signals in real time In vitro amp Cellular Pharmacology CSS E The new Tissue Bath Stations pro pesn mime a SC vide students with research quality
64. cessory Pack BSLAPH TA p 42 14 T T r gt F Suitable for inquiry based active learning in 2 yr amp 4 yr 52 lessons targeted for Biology ECG EEG EMG EOG amp EGG Respiratory amp Pulmonary Function Temperature pH Dissolved O Gas Analysis O2 amp CO Oxygen uptake Blood Pressure Cardiac Output via bioimpedance Stroke Volume Tissue Baths Force Calorimeter Interface Pulse Autonomic Nervous System Nerve Conduction Velocity Colorimetry Tools programs medical schools and nursing programs Biology covers a wide spectrum of applications To complement those outlined below see the applications detailed for Human Physiology page 10 and Animal Physiology page 12 As with all disciplines the selected applications only begin to suggest what you can do with the BSL System Contact a Biopac Student Lab Specialist to discuss your application needs Cardiovascular Lessons include blood pressure ECG analysis heart sounds and pulse Students can make single three six and 12 lead ECG recordings familiarizing themselves with Einthoven s saa triangle and mean electrical axis of the a i ECG frontal plain Students perform blood ESERIES Lp pressure measurements using a cuff with stethoscope employing Korotkoff sounds to make determinations of systolic dias tg Lesson 7 ECG amp Pulse File name Bret
65. ction Velocity page 44 H17 Biomechanics Goniometry amp EMG page 44 H28 Reflex Response patellar tendon page 44 H35 Range of Motion Sit amp Reach page 45 See Core Psychophys on page 19 Adds these lessons H21 Impedance Cardiography CO page 43 H30 Stroop Effect page 44 H31 Prepulse Inhibition page 44 See Core Biomed on page 21 Adds these lessons H03 Nerve Conduction Velocity page 44 H21 Impedance Cardiography CO page 43 See Core Pharm amp Tox on page 23 Adds this lesson A05 Visceral Smooth Muscle page 45 BSL LESSON 5 ECG I Record Lead II ECG and examine components of the ECG complex as an introduction to the electrocardiograph and the recording of the heart s electrical signal BSL LESSON 6 ECG II Record ECG using bipolar Leads I and III the software calculates Lead II to demonstrate Einthoven s law BSL LESSON 7 ECG amp PULSE Use a pulse plethysmogram transducer and Lead II ECG to examine the mechanical action of the heart and peripheral pulse pressure to learn how the heart pumps blood through out the body BSL LESSON 16 SYSTEMIC BLOOD PRESSURE Record arterial blood pressure using the ausculatory cuff technique Korotkoff sounds using an amplified stethoscope and ECG using Lead II BSL LESSON 17 HEART SOUNDS Record ECG Lead II and place an amplified stethoscope at four different locations to listen to the sounds of the heart s valves and correlate the sounds
66. cure adjustable head strap AFT10S Strap AFT10S This fully adjustable non latex reusable head strap holds the AFT10 disposable facemask securely to the subject s head Use one strap to securely fasten the mask 1 per pkg The following items interface with the Airflow Transducer SS52L page Premium Calibration Syringe AFT26 33 which is intended for exercise physiology and other high volume pulmonary function studies To use with the SS11LA Airflow Transducer page 27 use AFT7 tubing and AFT11E coupler T Valve AFT21 High performance very low dead space low airflow resistance valve suitable for high airflow applications Interface with the as Airflow Transducer SS52L via the Tubing 2 x AFT7 and Coupler Proves durability Works with Airilow Transducers or the AFT11F and the GASSYS2 All ports are 35 mm OD and 30 mm GASSYS2 and fits AFTT tubing 35 mm OD coupler ID AFT11D coupler included to fit AFT4 filter See Lessons BSLI2 BSL13 H29 H19 page 43 Head Support AFT24 Tubing AFT7 Use the head support when breathing directly Smooth bore tubing for use with Airflow Transducers SS11LA or into the AFT21 non rebreathing T valve for SS52L and other large bore accessories such as the AFT25 exercise physiology measurements The AFT24 Facemask with Valve or the AFT21 T valve for gas analysis secures the AFT21 directly in front of the sub studies included with the GASSYS2 35 mm ID 38 mm OD ject and min
67. cy amp Interchangeability 02 C See Lessons BSL8 BSL15 pages 43 44 See other Temperature Sensors on page 28 SS7L and SSS8L Hand Switch SS10L Use this hand switch for remote event marking or for psychophysiological response tests Monitor switch data as an input channel Connects to any analog input channel Switch type momentary push button See Lessons BSL11 H11 H16 H24 H27 H30 pages 43 44 See digital switch options for the MP36 unit on page 30 SS53L SS55L Headphones Use headphones to listen to real time physiological signals like EMG or to present auditory stimuli OUTIA Ultra wide frequency response headphones 40HP Monaural headphones Connect to headphone Connect to headphone port on MP36 only port Ships with MP45 BSLHScS Systems See Lessons BSL1 BSL2 BSL11 H09 H16 H31 pages 43 44 See the Tubephone OUT101 on page 31 MP35 30 users Visit BIOPAC online for OUTI headphones with analog out connection Unless otherwise specified all transducers connect don t have to worry about plugging things in directly to the MP36 acquisition unit and have a3 upside down or into the wrong socket We offer a meter cable All BIOPAC Simple Sensor transduc wide range of transducer interface connectors so er connectors are DSUB 9m for analog input and that you can connect your existing equipment or DSUB 9f for output There is only one way to plug you can build your own interface by using one of Simple Se
68. d from the cock roach ventral nerve and for a variety of intracellular and extracellular recordings In vitro Applications The new Tissue Bath Stations provide students with research quality equipment in a modular flexible configuration The Visceral Smooth Muscle lesson guides students through the entire recording and analysis process Students can also electrically stimulate tissue preparations including field stimulation with the BSL Stimulator Interface with Ussing chambers for ion transport studies Record and analyze data from isolated heart and lung experiments The following hardware suggestions will enable you to perform a wide variety of applications targeted for animal physiology Use BIOPAC lessons or easily create your own experiments with the BSL PRO software included with each system Order the core package or select items la carte See BSL Hardware page 23 for all available transducers electrodes and accessories Animal Physiology Core BSLAPH W Win or BSLAPH M Mac Basic BSL System with BSLCBL8 substituted for SS2LB BSLBSC p 8 Dissolved Oz Probe Interface BSL TCI16 p 39 Force Transducer 200 g SS65L p 31 Lead unshielded x 2 LEAD110 p 36 Leads shielded x 2 LEAD110S W R p 36 Low Voltage Stimulator SS58L p 25 Needle Electrodes x 3 EL452 p 38 Nerve Chamber NERVE2 p 38 Recording Nerve Cable BSLCBL4B p 39 Stim Electrodes for animals ELSTM2 p 38 Stimulator Nerve C
69. d warning LED flashes when a stimulus pulse is output Connects to the Analog Out on the back of the MP36 Reference Output Cable Stimulus marker output cable connects to any of the four analog input channels on the MP36 to record the stimulator marker pulse Reference Switch controls the output signal pulse width to Actual or Fixed 15 ms Diagnostic test switch sends a fixed pulse width of 2 5 ms The BSL Stimulator plugs directly into the MP36 and is controlled by the BSL PRO software The PRO software is used to set up the stimulation pulse width frequency and output single pulse or series options and automatically notes any change to the stimula tor parameters e g pulse width and frequency by inserting an event marker with descriptive text at the point of change The stimulator Preset automatically scales the display for pulse ampli tude The BSL Stimulator can be set to start automatically with the recording or manually at any point during the recording Stimulus data can be displayed and monitored independently of the sample rate or stimulus frequency Use with the HSTMO1 page 28 for human subjects Shielded Lead Set SS2LB General purpose electrode lead two SS2LBs are included with every BSL System The SS2LB cable connects disposable electrodes to the MP36 unit to measure biopotential signals Each lead set has three pinch leads that snap directly onto standard disposable electrodes such as the EL500 series
70. dSuppot Exercise Physiology See Lessons H29 and H19 page 43 AFT24 page 35 Mouthpieces Disposable and reusable options AFT2 page 34 AFT8 page 34 AFT9 page 35 Nose Clips Reduce leakage errors in mouth breathing circuits AFT3 page 34 Student Pack Multi purpose airflow accessories for use with the SS11LA Used in BSL Lessons BSLACCPACK page 34 T valves non rebreathing Standard and High performance options See Lessons H29 and H19 page 43 AFT21 page 35 AFT22 page 34 Tubing Interface the Airflow Transducers SS11LA and SS52L with the GASSYS2 AFT7 and AFT7 L page 35 See Lessons H29 H21 H19 page 43 36 alectrodes amp recording acce Recording cables require multiple leads and electrodes and accept Touchproof connections Shielded Electrode Adapter SS1LA Interfaces the MP36 with shielded or unshielded reusable surface and needle electrodes such as the EL250 and EL450 series Accepts Touchproof 1 5 mm socket electrode leads Can be used as an alternative to the SS2LB for reusable electrodes Adapter CBL201 If you have an older model SSIL use CBL201 to convert the 2 mm pin connection to the Touchproof 1 5 mm connection recording electrode Pinch Leads LEAD110 Series Lead110 series electrode pinch leads terminate in standard Touchproof connectors for interfacing to the SS1LA BSLCBL8 or BSLCBL9 These leads have no ferrous parts Use shielded leads for min imal noise i
71. dent L oe a muss nts and settings FrazerFin Nerve Recordings amp Compound Action Potentials BIET MI cockroacaes casia t ay anaj Gcr ai Ose Add a range of drugs and determine Membrane Transport drug delivery Tissue Baths Stimulation amp Response the effect they have on the nerve The new Nerve Chamber includes a drug Isolated Heart Lung Muscle delivery chamber agent well with lid Auditory Somatosensory amp Visual Evoked Response to maximize the quality of the results Compatible with Crawdad Lab Manual and improve experimental repeatability 132996 40 133041 40 pes a 13313140 Suitable for inquiry based active learning in 2 yr amp 4 yr ass aay T o C s gt E programs medical schools and nursing programs MAP Guinea Pig Biopac Student Lab PRO CDa ts ni l File Edit Transform Display Window T Help isl Eja JC Ea gt EMG 30 500 Hz Neurophysiology Study EEG under a variety of conditions to explore relax ation and brain rhythms the software can filter and display each rhythm separately Alpha Beta Delta and Theta Select from a variety of PRO Lessons to study Alpha rhythms in the occipital lobe reaction times and hemispheric asymmetry Add the EOG ocular signal to study eye movement saccades tracking angular A P Herve displacement or ocular fixations Use the stimulator to study evoked response auditory v
72. dents can record data which makes the whole laboratory experience much more productive For open ended learning use the BSL System for student projects and research or use it to quickly create your own lessons e Adapt student task protocols to develop critical thinking skills e Modify or expand BSL Lesson segments for hypothesis driven studies What will you do with the Biopac Student Lab Quick click curriculum options let you use the lessons any way you want A Use existing BSL Lessons to study the fundamentals of physiological systems like cardiovascular B and pulmonary function Use 45 BSL PRO Lessons developed by instructors to explore principles like Habituation Impedance Cardiography and Nerve Conduction downloads include lesson setup procedure and data template Customize BSL lessons to incorporate your protocols add advanced analysis tools and or use existing equipment Develop lessons with new or existing curriculum and BSL software tools like FFT Histogram Trigger Averaging and Rate Detection Add setup amp onscreen instructions and then save as a template Allow students to design their own research projects Use BSL Lessons as a starting point for inquiry based experiments then modify or expand recording parameters and protocols to test hypotheses Lesson development made easy for you and your students Create your own lesson in just a few simple steps l 2 Pick from
73. diagnosis H03 NERVE CONDUCTION VELOCITY Record responses along the ulnar nerve of a human subject to observe the Threshold Maximal and Supra Maximal response levels and determine nerve conduction velocity along the ulnar nerve H09 AUDITORY EVOKED POTENTIAL AEP Present an auditory stimulus to a human subject and record Auditory Evoked Potential H10 HEMISPHERIC EEG Record EEG and study effects of sensory stimulation or change in attitude attention on alpha rhythm beta rhythm and hemispheric asymmetry H11 MIRROR TEST SENSORY MOTOR LEARNING amp EDA Correlate efficiency in a task requiring movement and atten tion focus with reticular tone which indirectly indicates emotional fluctuations and analyze performance over repeated trials H12 SACCADES EOG Explore applications of electrooculography and observe the constant saccade durations for a variety of given angular displacements H13 TRACKING EOG Observe tracking movements used while watching a moving object and demonstrate the difference between eye movement based on actual visual stimulation and imagined recreations H14 FIXATION I EOG Record horizontal EOG and observe Ocular Fixation while reading H15 FIXATION II EOG Record a horizontal and vertical EOG and observe spontaneous gaze changes produced when viewing an image and then correlate results from the plot with the subject s attitude or level of interest H16 REFLEXES amp REACTIO
74. e BP with isometric or straining exercise H05 WINGATE TEST WAnT Record the Wingate Anaerobic Test and complete calculations H17 BIOMECHANICS Goniometry amp EMG Record muscle activity from the triceps and biceps while recording angle of limb movements H18 EXERCISE PHYSIOLOGY Blood Pressure Record Automatic Noninvasive Blood Pressure in pre and post exercise conditions and compare the conditions RESP amp PULM NEUROPHYS EX PHYS ANIMAL page 43 pages 43 44 page 44 page 45 H35 RANGE OF MOTION SIT REACH Students use a goniometer to record angle of joint movement i e hip ankle etc during a Sit amp Reach test H36 MUSCULAR BIOFEEDBACK Students record EMG and use auditory and visual bar graph biofeedback and touch to increase muscle performance BME BIOMEDICAL ENGINEERING H02 COMPARTMENTAL MODELING Explore Westheimer s saccadic eye movement model which represents the eye as a 2nd order system Record eye motion via EOG setup and compare to modeled results H20 FILTERING Design and develop software based digital filters to perform a variety of physiological signal filtering tasks Cascade 2nd order biquads to create high order filters H25 SIGNAL PROCESSING BREADBOARD I 8 Circuits Schematic and design notes for Square Wave Oscillator Instrumentation Amplifier High Pass Active Filter Active Gain Block and Low Pass Filter Notch Filter for 60 Hz Rejection ORS Detection Band Pass Filt
75. e BSLSTMB Stimulator for human stimula tion The ergonomic design allows the user to focus on electrode placement when locating a subcutaneous nerve Stimulus presentation is allowed by pressing the red safety switch and stopped by releasing it Complies with IEC 60601 2 10 for limitation of stimulation signal and interfaces with the BSLSTMB stimu lator BNC connector Isolation Voltage 1500 Vsus Isolation Capacitance 120 pF See Lessons H03 H06 pages 43 44 EDA GSR Transducer SS3LA Measure electrodermal activity and response galvanic conductance GSR The built in reusable electrodes fit around the tip of a person s finger and attach via Velcro straps or can be taped to any other body part Electrode Type Ag AgCl shielded Excitation 0 5 V DC constant Range 0 1 100 uMho normal human range is 1 20 uMho Surface Area 6 mm diameter contact area Gel Cavity Depth 1 66 mm Dimensions 16 mm long x 17 mm wide x 8 mm high each H See Lessons BSL9 BSL14 H11 H24 page 44 See the EDA GSR Disposable Option SS57L on page 26 Waterproof Temp Probe SS7L Liquid Immersion Temp Probe SS8L Use this vinyl probe for core oral rectal Use this stainless steel probe for dry or wet bath 2 8 temperature recordings temperature measurements Response time 1 1 sec Response time 3 6 sec Max operating temp 100 C Max operating temp 100 C Accuracy amp Interchangeability 0 2 C Accuracy
76. e Cardiac Output Sensor data greatly simplifies previously complex procedures to allow students to record stroke volume and cardiac output Combine these signals with ECG and blood pressure to demonstrate cardiovascular regulation by the Autonomic Nervous System The system can also perform detailed Heart Rate Variability tests and Averaged ECG recordings Muscular Students can measure EMG and Integrated EMG including force and angle of limb movement They can listen to the sound of the electrical activity coming from the zax muscle as they squeeze a hand dynamometer and Biopac Student Lab PI ents File Edit Transform Display Window MP30 Help m n Display Wi M aj xl Xe LT Jel equate changes in sound form and intensity with changes in force Add the BSL Stimulator and human safe stimulation electrode for a variety of muscle stimulation experiments Use the Tri Axial Accelerometer to examine movement of limbs head and torso in three dimensional space Couple the resultant acceleration velocity and distance data with 4 Ready Grid Off Chart Disk EMG data Gm NE EMG recordings to obtain a comprehensive picture of ata Goniometer Triceps Biceps skeletal muscle performance E0G Students can record horizontal and vertical eye move ments while observing fixation and tracking The X Y display mode will plot horizontal vs vertical eye movement to track eye position relative to an image or object By usin
77. ect to change without notice core packages BIOPAC offers a comprehensive line of electrodes transducers and accessories that work for a wide variety of applications Core packages are just one ordering option any system can be used as a starting point to develop your own custom package e The BASIC System is the foundation for MP36 based packages e The INTRO System is the foundation for MP45 based packages e The BASIC ADVANCED and ULTIMATE Systems with MP36 provide a general system for cross disciplinary users e The BSL Health Science System BSLHScS with MP45 provides a budget beating solution for any lab looking to add a physiology component e The BASIC ADVANCED and ULTIMATE Systems have been offered since the Biopac Student Lab was launched in 1995 and are now in use in thousands of labs worldwide e The CORE packages are offered to meet the diverging require ments of specific departments Review the Core Package Components table to determine which package meets your requirements or talk to a Biopac Student Lab Specialist to create your own custom package Packages contain everything including consumable items necessary to run a specified number of lessons specific to that particular discipline Each package is discounted to reflect the number of transducers and accessories included If you have existing transducers that you d like to continue using you can select from more
78. ed response auditory visual or somatosensory The new high speed MP36 hard ware allows for the recording of spontaneous nerve activity continuously at speeds of 100 000 samples a second Add the SuperLab stimulus presentation package to perform psychophysiology stimulus response protocols examining high level brain activity Conduct microelectrode recordings and study action potentials Autonomic Nervous System Record a wide variety of ANS related signals such as EDA GSR temperature ECG pulse respiration airflow nerve conduction continuous blood pressure and continuous non invasive cardiac output using bioimpedance technique to demonstrate changes in the parasympathetic and sympathetic nervous system activity Use the Polygraph lesson for simultaneous heart rate electrodermal activity GSR and respiration rate See Psychophysiology amp Neurophysiology on page 18 for more details Exercise Physiology amp Biomechanics Combine a wide range of respiratory system and pulmonary function signals with biomechanical data Use the new Gas Analysis Module for online analysis of expired O2 and CO levels Options are available for continuous blood pressure and cardiac output and the system easily interfaces with force plates and other instrumentation more than 18 ready made connectors available There are more than 27 specialized lessons see page 16 for details Dynamic lessons engage students The following hard
79. electrodes Red positive white negative and black ground Each 1 meter pinch lead terminates in a yoke connected to a 2 meter cable total length 3 meters Used in over 30 Lessons to record ECG EEG EGG EMG EOG etc see page 46 Core Animal and Core Pharmacology substitute BSLCBL8 for SS2LB See also SS1LA BSLCBL8 and BSLCBL9 page 36 See Lessons A02 A03 A08 A09 H03 H06 H09 page 43 See Lessons A02 A03 A08 A09 page 45 BSLSTMB for MP36 35 and BSLSTMA for MP30 BSLSTM Specifications Pulse level amplitude Range selectable Pulse width Pulse repetition Stimulator isolation Capacitance coupling Power requirements 10 V Range or 100 V Range 025 10 V or 12 100 V 0 05 100 milliseconds 5 seconds 0 5 milliseconds 0 2 2 000 Hz 2 000 Vans DC HI POT test 60 pF BSLSTMB for MP36 35 no additional power required BSLSTMA for MP30 12 V DC 1 Amp adapter included Fuse 250 V fast blow 2 Amp Module dimensions 16 cm x 16 cm x 5 cm 610 grams Compliance IEC 60601 2 10 section 51 104 See www biopac com for detailed specifications MP36 nid in SUUS Adapter OUT3 The MP36 includes a built in low voltage stimulator that is accessed via the Analog Out port DUC ME with OUT3 The OUT3 and BSLCBL2A female BNC adapter nerve chamber cable outputs signals and supports easy connection to nerve chambers stimulation electrodes clip leads LED lights and more Low
80. ent Set up acquisition and recording automation repeat trigger autosave core packages amp applications The Biopac Student Lab System is the total solution for a wide variety of scientific applications including human animal organ and tissue studies BSL Systems are available for general science Basic Advanced and Ultimate Systems and core disciplines Each Biopac Student Lab System includes a high performance data acquisition unit plus electrodes transducers and consumable items required to run a specified number of lessons for each particular discipline Any package can be used as a starting point to develop a custom system Electrodes and transducers can be purchased separately in order to perform additional lessons not covered with the core package and hardware upgrade kits are available e The BASIC ADVANCED and ULTIMATE Systems have been offered since the Biopac Student Lab was launched in 1995 and are now in use in thousands of labs worldwide in 2 year and 4 year programs medical schools nursing programs veterinary programs chiropractic colleges etc e The new CORE packages are offered to meet the diverging requirements of specific departments i BSL Lab Manual one with ISBN 978 1 4652 2952 6 Main 10e ISBN 10 0321822323 each system Pig 11e ISBN 10 0321822331 Human Physiology page 10 MANBSL4 18 lessons Cat 11e ISBN 10 032182184X Animal Physiology page 12 MANBSL4 45 11 lessons
81. er ORS Detection Absolute Value Circuit ORS Detection Low Pass Filter H26 SIGNAL PROCESSING BREADBOARD II System Block diagram to build ECG Signal Processor with SS39L H33 FFT FAST FOURIER TRANSFORM Build up a square wave from cosine components and use the FFT function to analyze the composite response ANIMAL A01 FROG PITH amp PREPARATION Explanation of how to pith and prepare a frog for experiments A02 A03 and A04 A02 FROG GASTROCNEMIUS New Scripted template guides students Directly stimulate the frog gastrocnemius muscle or stimulate the muscle via the sciatic nerve and record threshold voltage and contractile responses po ga TE phi e e a H ee at a n n i A03 FROG SCIATIC NERVE New Scripted template guides students Record compound action potentials of the dissected sciatic somatic motor and sensory nerve A04 FROG HEART CARDIAC RATE amp CONTRACTILITY New Scripted template guides students Record cardiac rate and contractile responses of the surgically exposed frog heart Option Study the effects of chronotropic and inotropic agents on the heart A05 VISCERAL SMOOTH MUSCLE Study the effects of media ionic composition temperature and various pharmacological agents on the contraction of the visceral smooth muscle of the rabbit ileum A06 COCKROACH VENTRAL NERVE Record nerve activity from the ventral nerve cord while stim ulating the cerci with puffs of air A07
82. er and allows instructors to set file storage location Onscreen prompts and expanded Help menu help students get good data with instructions and videos for setup calibration recording and file management Sophisticated measurement tools help students extract and easily report meaningful data iiti i HELLET i EEE EE HIB PA IE PF E NND nA n N ED ee GEL JELI E A BSL system was used in a stud aboard the Vomit Comet in the Zero G program at the NASA Johnson Space Center by Dr Rick Puzdrowski and students from the University of Houston Clear Lake School of Natural and Abplied Sciences Students Carolyn Jessop left and Sonya Morgan with JSC techs in blue Source NASA Johnson Space Center http l zerog sc nasa gov Presets simplify setup for custom projects Presets include all amplifier and filter settings for the signal to optimize data collection and display Presets can be used as is or customized and saved under a new preset name for your protocol Organize and or limit the list of Presets displayed to further simplify setup facilitate learning amp enhance The BSL System helps students get on track right away with data acquisition and analysis The hardware has no knobs or dials and the lesson software uses automatic calibration and onscreen prompts These features eliminate confusion and frustration and save a lot of time in the lab More stu
83. er ri The acrylic desktop Nerve Chambers incorporate 15 stainless steel electrodes for recording and stimulating a variety of different nerve preparations Each stainless steel electrode is spaced 5mm apart to provide a variety of recording and stimulating con figurations Chambers have a 35 ml reservoir and include a drain with valve and hose Interface with the BSLSTMB or SS58L stimulator via BSLCBL2A and BSLCBL4B nerve conduc tion cables The NERVE1 chamber includes a convenient agent well for adding compounds ether or dry ice etc and a lid to enclose the preparation when protocol requires it Dimensions cm 4 5 h x 7 w x 14 I NERVE with agent well and lid NERY Banda chamber Nerve Chamber Recording Analog Out Cables BSLCBL4B BSLC BNC Output OUT2 EF Analog output cable connects to the Analog Out port on the rear of the MP36 DSUB 9m connector The cable terminates in a male BNC connector See OUTIA Headphones on page 26 P BSLCBL2A Input BSLCBL3A banana plugs x 3 for third party nerve chambers BSLCBL4B 2 mm pin plugs x 3 for BIOPAC NERVEI amp 2 BSLCBL3A and BSLCBL4B Specifications Custom eis Interface SS KIT OUT The kit comes with a Simple Sensor connector cable and components Gain 1 10 divide by 10 Input Impedance Common Mode 500 GigaOhm to properly interface with speakers common Meade ejection vor stimulators and other equipment Input Bias Current
84. erLab via USB to the MP36 35 via the STP35 cable sold separately The STK100 includes Stimtracker device and two photocells and works with your existing copy of SuperLab SuperLab Interface Cable STP35 If you already have SuperLab and an MP36 35 unit you can use the STP35 Interface Cable to connect the two systems The STP35 Cable interfaces with the I O Port on the rear of the unit Iw P I pg eas Noninvasive Blood Pressure Monitoring NIBP100D Initial setup and calibration period takes less than three minutes anta lon E Prime is a powerful suite of applications combining precise millisecond timing a user friendly environment and the flexibility to create simple to complex experiments for both advanced and novice users MP36 or MP35 Systems Use the STP35A 3 meter ribbon cable sold separately see below to interface the computer printer port to the I O Port on the back panel of the MP unit Note Second PC Required EPM100 E Prime 2 0 Software Standard Edition EPMIOOP E Prime 2 0 Professional offers enhanced capabilities for more sophisticated presentation designs Parallel Port Interface Cable STP35A Use to connect MP36 35 system to the parallel printer port of the computer running E Prime Can also be used with MediaLab DirectRT and Inquisit Visual Stimulation for Evoked Response Stroboscope TSD122C The stroboscope connects directly to the MP36 Input or Output channels for visual
85. erage or perform measurements on each response in the stimulus classification Facial EMG electrodes Biopac Student Lab MeganMP35 L03 Cl x File Edit Display Lessons Help Evoked Response P Overlap Split Lessons guide students through EIL are delta evoked response recordings Use the system to trigger a stimulus and derive the average response Use with headphones stroboscope or electrical or mechanical stimulation for audito IY visual or somatosensory response jf EEG filtered from Lesson 3 5 00 12 00 1400 16 00 18 00 2090 2 2200 2400 26 00 mf EEG Introductory lessons allow students to record EEG and look at the differences between Alpha Beta Delta and Theta activity levels Students can record EEG from both hemispheres while listening to music reading and Documents Ini x 1 1 File Edit Transform Display Window MP30 Help l xl performing mental tasks The software guides them TL BUR through the recording and then shows them how to ARAARA RARI AN n J analyze the frequency components of the signal The Fast Fourier Transformation is used to show the frequency levels of the activity on each hemisphere a oO G m Cardiovascular Students can record the changes in pre ejection period 523 07 27 91 seconds Chat Memory and cardiac output relative to a variety of different Noninvasive blood pressure stimuli The new noninvasiv
86. ersity of Wisconsin University of Wyoming Victor Valley College Wake Forest University Washington University Whittier College Yale University Yavapai College Yuba College Universit des Antilles et de la Guyane Universit du Maine Universit du Qu bec a Chicoutimi Universit du Qu bec a Montr al Universit Facult de M decine Angers Universit Facult de M decine Brest Universit Facult de M decine Nimes Universit Facult de M decine Vandoeuvre niversit Paris 8 niversiti Kebangsaan Malaysia niversiti Malaya niversiti Putra Malaysia niversiti Sains Malaysia niversiti Teknologi Malaysia niversiti Teknologi Mara niversity College Northampton University of Bergen University of Cambridge University of Crete University of Delhi University of Derby University of Glamorgan U U U U u U U y U U U U U niversity of Glasgow niversity of Gloucestershire niversity of Nottingham niversity of Oxford niversity of Surrey Roehampton University of the West of England University of Toronto University of Vienna Waseda University Yamagata University BIOPAC WE iens nc ASIA PACIFIC Australia SDR Scientific 206 354 Eastern Valley Way Chatswood NSW 2067 Australia Tel 61 2 9882 2882 Fax 61 2 9882 6468 E mail info sdrcom au Web www sdr com au China A Upwards Teksystems Ltd Room 1806 Kuntai International Mansion A Bldg No 12B Chaowai Street Beijing
87. es amp Research Queensland University of Technology Rajguru College of Applied Sciences Rijksuniversiteitt Groningen Royal College of Surgeons in Ireland Sedaya International College Semmelweis Medical University Showa University Singapore Polytechnic Taipei Medical University Taipei Municipal Physical Education College Tamagawa University Technological Educational Institute of Heraklion Trinity College Dublin Ubolratchathanee University Universidad Alberto Hurtado Universidad Aut noma de Centro Am rica Universidad Aut noma de Coahuila Universidad Aut noma de Madrid San Francisco State University San Jose State University Santa Barbara City College Santa Monica College Santa Rosa Junior College Seattle Pacific University Shasta College Sierra College Skidmore College Solano Community College South Mountain Community College Stanford University State University of NY Stony Brook University Taft College Texas A amp M Tulane Univ School of Medicine Tuskegee University University of Arizona University of California Berkeley Riverside San Francisco Santa Barbara University of Colorado University of Connecticut University of Delaware University of Florida University of Georgia University of Hawaii Hilo University of Illinois University of Kentucky University of Maryland University of Massachusetts Universidad de C diz Universidad de Costa Rica Universidad de Extremadura Universidad de
88. es electrodes require adhesive disks ADD200 series and recording gel GELI or any preferred recording gel see page 36 Available shielded or unshielded Shielded use one color lead for electrode contact and a different color lead for shield EL254 4 mm contact 7 2 mm housing unshielded Ag AgCl EL254S 4 mm contact 7 2 mm housing shielded Ag AgCl EL258 8 mm contact 12 5 mm housing unshielded Ag AgCl EL258S 8 mm contact 12 5 mm housing shielded Ag AgCl See Lesson H27 page 43 Bar Electrodes for Animals EL350 Series Use on animals to record a signal during nerve conduction somatosensory or muscle twitch studies The bar configuration permits easy electrode placement without disturbing electrode to electrode spacing Two tin electrode disks are placed 30 mm apart in a watertight acrylic bar non ferrous When using bar electrodes for signal recording a single ground lead LEAD110 with EL503 is required The leads 6lcm long terminate in standard Touchproof 1 5 mm socket connectors which connect to the SSILA BSLCBL8 or BSLCBL9 lead adapters EL350 Unshielded concave bar lead electrode EL350S Shielded concave bar lead electrode EL351 Unshielded convex bar lead electrode See the HSTMOI on page 28 for use on human subjects 3 38 electrodes reusable Needle Electrodes EL450 Series Use for recording in animal subjects and tissue preparations Shipped non sterile so pre
89. ess to work with BIOPAC force transducers evoked response applications i e ABR 31 32 a TOLLE S e al ANd a af OF im SuperLab SuperLab presents visual or auditory stimuli and simultaneously 1 ms resolution sends trigger signals to the MP36 for data synchronization and collection purposes Images and sounds are presented on a second computer screen auditory stimuli via headphones or speakers Images and sounds are grouped by type and have a digital sync signal assigned to each group As each image or sound is presented a sync pulse is sent to the MP36 The BSL software identifies the pulses and provides the average response to the group stimulus Measurements can be taken over the response data such as max min mean time of max etc Note Second PC Required SuperLab System for MP36 35 STP35W Complete SuperLab package for the MP36 35 Includes an interface cable permitting up to eight synchronization signals input or output between the STP35W and the BSL System Different trigger channels can be paired to different visual or auditory stimuli to perform sophisticated evoked response averaging tests e g P300 The STP35W also includes a six pushbutton response box for per forming accurate reaction time measurements See Lessons H24 H27 H30 H31 pages 43 44 StimTracker Marker Interface STK100 r The StimTracker delivers markers from the stimulus presentation computer running Sup
90. g the zoom and measurement tools students can measure duration of saccades and fixation A simple light fixture becomes an excellent tool for measuring angular displacement EDA mirror test Lesson HI 1 Nerve Conduction Combine the human sate stimulating electrode with the stimulator to record nerve con duction experiments Stimulate the ulnar nerve at three different points and record nerve conduction time Measure the distance between the stimulation and recording points and then calculate the velocity of signal propagation along the nerve motor response Use the Finger Twitch transducer coupled with nerve stimulation to examine the relationship between applied external nerve stimulation and associated motor recruitment ophysiology amp neurophysiology The following hardware suggestions will enable you to perform a wide variety of applications targeted for psychophysiology amp neurophysiology Use BIOPAC lessons or easily create your own experiments with the BSL PRO software included with each system Order the core package or select items a la carte See BSL Hardware page 23 for all available transducers electrodes and accessories Psychophysiology Core BSLPSY W Win or BSLPSY M Mac Basic BSL System BSLBSC p 8 BP Cuff Transducer SS19LA p 27 Colored Paper for BSL9 PAPER1 EDA GSR Lead SS57L p 26 EDA Isotonic Electrodes 100 pk EL507 p 37 Electronic Stethoscope Transducer SS30L p 28
91. grams physiology We have been using the Biopac Student Lab system in our Human Anatomy amp Physiology labs at IU South Bend for about 5 years Students enjoy being able to analyze data that was generated from a member of their lab group It certainly has more meaning to them than using traditional canned lab data WMaary Truex Indiana University South Bend Biology Department Cardiovascular The BSL System covers a wide range of cardiovascular measures based on the heart s electrical signal Record standard LI LII or LIII or augmented aVR aVL or aVF leads add a multi lead ECG cable to simultaneously record a pre cordial lead Students attach Leads I and III and the software uses Einthoven s law to display Lead II Identify isolate and measure Biopac Student Lab ElieMP35 L17 4s components of the ECG complex under File Edit Display Lessons Help are varying conditions Use the averaging features to automate ECG analysis View arrhythmia data obtained from the NIH PhysioBank archive Calculate R R inter val to display heart rate variability or l m sean Source determine vagal tone Use the electronic File name ElieMP35 L17 Ez ae i stethoscope to listen to and record heart Overlapped ECG and heart sounds and then correlate the sounds sounds with the mechanical and electrical events of the cardiac cycle Record cuff pressure and Korotkoff sounds to measure systolic and diastolic bl
92. hysiology by Wyttenbach Johnson and Hoy ISBN 0 87893 947 4 mmHg 0 00 20 00 40 00 60 00 minutes Dissolved oxygen goldfish Comparative Biology The Biopac Student Lab system is an excellent tool for comparative biology programs because students can compare data from their own bodies with data recorded from a variety of animals The curriculum covers most of the major physiological systems including brain muscle pulmonary cardiovascular and CNS The following hardware suggestions will enable you to perform a wide variety of applications targeted for biology Use BIOPAC lessons or easily create your own experiments with the BSL PRO software included with each system Order the core package or select items a la carte See BSL Hardware page 23 for all available transducers electrodes and accessories Biology Core BSLBIO W Win or BSLBIO M Mac EDA Isotonic Electrodes 100 pk EL507 p 37 Basic BSL System BSLBSC p 8 Electrode Gel GEL1 p 36 Airflow Filters 10 pk AFT1 p 34 Electronic Stethoscope Transducer SS30L p 28 Airflow Mouthpieces 10 pk AFT2 p 34 Force Transducer SS12LA p 27 Airflow Nose Clips 10 pk AFT3 p 34 Hand Dynamometer SS25LA p 27 Airflow Transducer SS11LA p 27 Hand Switch SS10L p 26 BP Cuff Transducer SS19LA p 27 Headphones OUT1A p 26 Calibration Syringe 600 ml AFT6A p 34 High Impedance Cable BSLCBLS9 p 36 Colored Paper for BSL9 PAPER1 Multi Lead ECG Cable SS29L p
93. ideal for graduate level studies and personal research Dophysiology amp neurophysiology Autonomic Nervous System Use the BSL system to record changes in the parasympathetic and sympathetic nervous system activity Acquire a wide variety of ANS related signals such as EDA GSR skin temperature ECG pulse Sonor stent Lab Pree 00 zx respiration airflow nerve conduction v Help m value j Hep csr Segment 1 3 35 46 PM continuous blood pressure and B2 veue Jp continuous noninvasive cardiac output bioimpedance method Simultaneous graphing shows heart rate electrodermal activity GSR and respiration rates After the experiment evaluate the data using the powerful and user friendly Electrodermal activity GSR from analysis functions Lesson 14 Event Related Potentials Combine the BSL with a visual presentation system such as SuperLab to explore a wide variety of experiments like Stroop Oddball Habituation and Startle Response SuperLab is user friendly and greatly simplifies devel opment of a range of visual and auditory presentations As each stimulus is presented SuperLab sends a digital pulse to the BSL System to mark the onset of the stimulus The stimuli are classified into different groups with each group assigned a unique digital chan nel The BSL software will identify the digital pulse and automatically measure the associated response and provide the av
94. ielded x2 Force Transducer 200g Needle Electrodes x3 Nerve Chamber Nerve Cable Recording Nerve Cable Stimulator pH Interface SS68L or other pH probe Hardware Options Part ships with system ships with system MANBSL4 4 45 on web SS2LB BSLCBL8 BSLCBL9 EL503 ELPAD SS11LA AFT6A AFT1 AFT2 AFT3 SS57L EL507 SS10L A OUT1A or B 40HP SS4LA SS5LB SS6L PAPER GEL1 TAPE1 A SS19LA or B SS19L SS30L SS12LA A SS2bLA or B SS56L SS29L SS13L BSLSTMB HSTMO1 SS58L ELSTM2 SS69L BSL TCI16 SS39L LEAD110 LEAD110S W amp R SS65L EL452 NERVE2 BSLCBL4B BSLCBL2A BSL TCI21 eThis table only lists parts included in CORE PACKAGES e For a full list of hardware options see the BSL Hardware section pages 24 40 or check the Index page 47 e All parts can be ordered individually you can add hardware options or create your own package to suit your curriculum Visit www biopac com or contact a Biopac Student Lab Specialist to discuss your specific application needs Page 24 2 7 40 43 45 Advanced Ultimate Human Biology Exercise Phys Psychophys Biomed Eng Pharm amp Tox Intro MP45 HScS MP45 Basic X X x MP36 X X x x MP36 x X x x MP36 X XxX x Xx MP36 X XxX x MP36 X X x x MP36 X X x x MP36 x lt x x MP36 X X x X MP45 X X XK X MP45 X X X X X X X KK x x X X X X X X X X X X A X X X X X X X X X X X
95. imizes the strain associated with meter valves and tubing AFT7 L 3 meters See Lessons H29 and H19 page 43 See Lessons H29 and H19 page 43 This 2 0 liter syringe provides a larger volume calibration value and is recommended for exercise physiology applications and higher quality more consistent calibrations where greater precision is required Aluminum casing racemask with Valve AFT25 Couplers art Series Use the AFT25 facemask when performing Couplers connect a variety of air flow gas analysis tests on an exercising subject or port IDs and ODs to transducers tubing for other high airflow applications The adult and calibration syringes Pick an AFT11 facemask has an integral high performance Series coupler that matches the port sizes non rebreathing T valve and very low dead that need to be interfaced space and low flow resistance Interface with Coupler Size Interface the Airflow Transducer SS52L via tubing 2 x AFT7 and AFTIIA 25MM OD 35 MMID AFT6Ato AFTI coupler AFT11E and the GASSYS2 AFTIIB 15MM OD 22 MMID AFTIO to SSIILA All ports are 35 mm OD and 30 mm ID AFTIIE 22MM OD 35 MMID AFTT to AFT22 25 See Lessons H29 and H19 page 43 AFTIIF 35 MM OD 45 MM OD SS52L to GASSYS2 H AFTIIH 35 MM OD 28 6 MM ID AFT13 to SSIILA Disposable Bacterial Filter AFTA AFT111 22MM OD 22 MMID AFT26 replacement coupler Use with the Airflow Transducer SS52L and the 35 mm reusable
96. ing such as hardware and subject setup background material and a student Lab Report with guided analysis for BSL Lessons One current manual is included with each system order additional copies through your bookstore for students Check online or contact BIOPAC for translation options including French Italian Japanese Russian or Spanish MANBSLA editions include 18 lessons BSL 1 17 and 20 MANBSL4 45 editions include 11 lessons BSL 1 6 10 12 13 16 17 MANBSL3 XX editions are for BSL 3 7 and include 18 lessons BSL 1 17 and 20 See also published Lab Manuals page 8 Battery Pack BAT100A For portability use the BAT100A rechargeable bat tery pack and charger with the BSL System The mainte nance free battery pack is built into a carrying case with a shoulder strap The fully charged battery will operate a BSL System for a minimum of 24 hours Includes battery pack universal recharger and all necessary cables Specify power cord ACCORD US USA or ACCORD EURO Europe Output Capacity 12V 15 amp hours Operating Time 26 hours nominal for MP36 with 4 transducers Charge Time 15 hours Dimensions 14 cm high x 19 cm wide x 14 cm deep Weight 2 45 kg Recharger Charge Voltage Max Nominal Charge 14 4V 3 0 amps Input 120 240 VAC 50 60 Hz Dimensions 3 8 cm high x 6 4 cm wide x 15 cm long Weight 285 g Upgrade to MP36 System Trade in Your MP30 or MP35 Packages specifications and lessons subj
97. integrated EMG signals overlap the signals for better correlation of the data Measure strength and repeat trials for motor unit recruitment summation and fatigue Use the reflex hammer transducer to study reflex 9 bere Sonn ELE control or add the d aa OIC men 975551Ha 3 pp Ihon response neural control or add the dynamometer to on study handgrip strength profiles Use the new Finger EE af Twitch transducer for threshold summation tetanus and fatigue analysis Students can listen to the muscle activity through headphones and note the increase in sound intensity as grip strength is increased through E usc se e motor unit recruitment MG and force Nerve Conduction Combine the human safe stimulating electrode with the stimulator to record nerve con duction experiments Stimulate the ulnar nerve at three different points and record nerve conduction time Measure the distance between the stimulation and recording points and then calculate velocity Neurophysiology Study EEG under a variety of conditions to explore relaxation and brain rhythms soft ware will filter and display each rhythm separately Alpha Beta Delta and Theta Select from a variety of lessons to study Alpha rhythms in the occipital lobe reaction times and hemispheric asymmetry Add the EOG occipital signal to study eye movement saccades tracking angular displacement or ocular fixations Use the Stimulator to study evok
98. isual or somatosensory The new high speed MP36 hardware allows the recording of spontaneous nerve activity continuously at speeds of 100 000 samples a second Add the SuperLab stimulus presentation package to perform stimulus response studies investigating higher order neuronal function in humans Conduct intracellular and extracelluar recordings with glass microelectrodes and Ag AgCl wire electrodes to study action potentials from a variety of subjects imx Respiratory amp Pulmonary Function File Edit Transform Display Window MP30 Help OU B eL The BSL System provides an excellent intro duction to respiratory system and pulmonary function volumes and capacities respiratory rates breathing and ventilation Display and or print a clinical grid on the data for effective interpretation and training A com plete range of airflow and pressure transduc ers is suitable for small medium and large ani mals as well as humans Flow vs pressure in X Y mode Gas Analysis Use the new gas analysis system for detailed metabolic studies in small and medium sized animals Chambers couplers facemasks and tubing options provide setup options for any protocol The system can provide online measures of Oz and CO for RER VO and BMR RMR Use the Dissolved O2 probe and lesson to measure the oxygen consump tion of a goldfish Intracellular amp Membrane Transport Use the new High Impedance Cable BSLCBL8 9 page 36 to recor
99. ith standard Touchproof connectors Input Impedance Common Mode 5e11 Ohms 500 GigaOhm Input Bias Current 3 pA Typical Voltage Noise 1 3 uV p p Voltage Noise Density 36 nV Hz Current Noise Density 0 01 pA N Hz BSLCBLS Attenuation none Input Range MP36 45 x2 V MP35 1 V MP30 70 mV BSLCBLO9 Attenuation 10 Input Range MP36 35 45 3 8 V MP30 700 mV See Lessons A06 All A14 page 45 See these lead options General purpose Electrode Lead Set SS2LB page 25 Multi lead ECG Cable SS29L page 27 Nerve Chamber page 38 Nerve Chamber Leads page 39 EDA Snap Lead see SS57L page 26 Cardiac Output Sensor SS31L page 29 lecti See also BSL ACCPACK page 34 includes all consumable items required to run BSL Lessons Hypoallergenic Gel Conductant for EL250 series reusable electrodes and the EDA SS3LA Transducer GELI 30 g GEL100 250 g Isotonic Gel GEL101 GEL101 is specially formulated with 0 5 saline in a neutral base and is primarily used as a conductant for the electrodermal activity GSR studies Recommended for research studies only 125 g Abrasive Pads ELPAD Use to abrade the skin to remove non conductive skin cells for improved signal quality Tape Attach goniometers and other devices to the body TAPE Single sided adhesive 9 1 meters TAPE2 Double sided adhesive 25 6 meters Adhesive Disks Two sided adhesive collars hold reusable electrodes
100. ization to suit your curriculum create your own lessons with no programming required Language options English French Spanish Japanese Italian Russian Biopac Student Lab Specialists available for Technical Support Lab Manual Options Use the Biopac Student Lab Manual included with each BSL System for up to 18 scientific lessons Use digital text of the lessons and create a custom lab manual with your own curriculum Select from major published Lab Manuals using BIOPAC lesson experiments see page 8 when you get the bsl they ll get science Normative values provided for FEVi23 MVV BP and ECG Arrhythmia lesson including sample data files from the NIH PhysioNet database Sample data files for male and female subjects Easily export for statistical analysis or archive student data aa dl om za c 70 Te o l me EE E E BSL 4 lessons show color setup images and videos to help students prepare for recording life science labs simplify your labs amp empower your students The BSL System helps students focus on scientific principles with Unmatched guidance power and flexibility Familiar point and click interface Extensive support materials to prepare for lab time including videos amp sample data files Onscreen prompts additional instructions help students record the highest quality data Online instructions guide the student through the lesso
101. l Web www eloserwis pl Portugal braineyes Rua Pedro Nunes IPN Quinta da Nora 3030 199 Coimbra Tel Fax 35 123948264 E mail braineyes braineyes pt Web http braineyes pt Romania Russi Scientific Instruments S R L Str Tudor Vianu Nr 3 Sector Bucuresti Cod 011635 Romania Tel 40 2 1 231 0538 Fax 40 2 1 230 1634 E mail info russi ro Web www aparatura ro Russia Bl REONIKA Ltd 19435 Russua Moscow Novodevichy 2 47 Tel 7 499 255 22 10 Fax 7 495 330 6157 E mail info transonic ru Web www transonic ru Spain Bi Bionic Iberica S A IM xic 8 08320 El Masnou Barcelona Spain Tel 34 93 540 19 09 Fax 34 93 555 6921 E mail info bionic es Web www bionic es Sweden JoR AB Rubanksgatan 4 741 7 Knivsta Sweden Tel 46 0 18 34 28 20 Fax 46 0 18 38 09 94 E mail jor jorse Web www jorse Turkey B COMMAT LTD Cetin Emec Bulv 74 Sok No 4 9 06460 Ovecler Ankara Turkey Tel 90 312 472 74 7 Fax 90 312 472 74 18 E mail info commat com tr Web www commat com tr United Kingdom and Ireland Linton Instrumentation Unit 1 Forge Business Centre Upper Rose Lane Palgrave Diss Norfolk England IP22 AP United Kingdom Tel 44 0 1379 651344 Fax 44 0 1379 650970 E mail mail lintoninst co uk Web www lintoninst co uk MIDDLE EAST AND AFRICA Egypt Al Geel Trading Co 25 Obour Buildings Salah Salem Road Cairo Egypt Tel 02 405 1455 Fax 02 40445
102. l for MRI applications Affix to subjects with nm sided adhesive TAPE1 page 36 This unob trusive multipurpose pneumogram transducer can 1 Noninvasively measure respiration from a small mouse to large rodent 2 Measure small pressing forces like pinching fingers together for Parkinson s evaluations 3 Measure human smiling with the sensor on the cheekbone 4 Measure pulse when placed close to the heart 5 Measure spacing and pressure between teeth coming together SS67L components 1 Differential Pressure Transducer SS41L page 30 1 Pheumogram Sensor RX110 below 1 Tubing 1 6m RX110 Replacement Sensor The RX110 is a self inflating pressure pad connected to tubing terminating in a Luer male connector The RX110 sensor is included with the SS67L Pneumogram Transducer pH Probe SS68L This double junction pH probe measures pH within the range of 0 14 Use the pH Probe Adapter BSL TCI21 page 39 to use a third party pH probe with the MP36 Order probe only as RXPROBEOI SS68L Components RXPROBEO1 and BSLTCI21 Output 5 mV pH 0 mV pH 7 Weight 99 22 g Length 3 25 cm Diameter 1 2 cm Dissolved 02 Probe SS69L Measures dissolved oxygen levels Includes electrolyte solu tion replacement membrane cap and replacement O ring Use the Vernier Adapter BSL TCI16 page 39 if you already have a Vernier Dissolved 02 Probe Order probe only as RXPROBEO2 SS69L Components RXPROBEO
103. left or right handed unit when ordering EL452 EL451 EL450 Travel Range Resolution X axis Fine 10 mm 0 01 mm X axis 35 mm 0 1 mm Y axis 25 mm 0 1 mm Z axis 25 mm 0 1 mm Use these clip leads to interface stimulating electrodes or to connect directly with an animal preparation Each 1 meter cable has two clips and terminates with one BNC connector to interface with the BSLSTMB or SS58L Stimulator page 25 and silver or platinum wire electrodes P BSLCBL11 BSLCBL BNC to 2x Alligator BSLCBLI1 BNC to 2x Electronic Test Clip spring loaded BSLCBL12 BNC to 2x Toothless Alligator mutation onti pu Stim Needle Electrode ELSTM2 Use when applying a stimulus to animal and tissue preparations not for use on humans connect to the BSLSTMB or SS58L stimulators page 25 The dual stainless steel needles are 2 5 cm long x 0 3 mm diameter and are Teflon coated Needle electrodes are shipped non sterile so pre sterilization is ee 2 5 meter us with BNC input See TES Aii m mE Electrode HSTMO1 page 28 and Field stimulation electrode BSLSTIMHLD page 33 Output Adapter BSLCBL6 Each stimulator lead connects to the BNC connector on the front panel of the BSLSTMB stimulator BSLCBL6 outputs signals from the BSLSTMB with a cable that termi nates in a 3 5 mm phone plug socket with a 1 3 m cable and can be used to connect headphones for auditory evoked response hamb
104. les allowing each to be a Subject and participate Students are more engaged when they analyze their own data nstructors can choose which experiments tasks within a lesson students will perform based on lab time restraints or on the level of the students Students verify that their data is correct after each experiment Students can analyze their data in the lab or at home by downloading our free analysis software Data reports are attached to each student s data file Measurements are taken sections of graphs can be copied and pasted and questions are answered Instructors can easily change the data reports Data reports can be printed or e mailed to the instructor Increased performance 24 bit A D converter Expanded amplifier settings New Stimulator and Output Controls Improved Electrode Check for electrode impedance New digital input amp S output capabilities Increased triggering options Instructor support materials Help your students get good data e The Biopac Student Lab System includes videos Data comparison tools for increased analysis Streaming data videos help students identify signal characteristics for of lesson procedure and recorded data tutorials sample data files onscreen prompts and a detailed lab manual to help students acquire high quality data Extensive curriculum library for human animal organ and tissue lesson experiments Easy custom
105. logy BSL7 ECG amp Pulse A01 Frog Pith amp Prep BSL16 Blood Pressure amp Korotkoff BSL3 EEG Relaxation amp Brain Rhythms BSL4 Alpha Rhythms in the Occipital Lobe BSL17 Heart Sounds amp Cardiac Events BSL9 GSR and Polygraph H01 12 Lead ECG BSL10 EOG Eye Movement Saccades amp Fixation BSL11 Reaction Time amp Learning BSL14 Biofeedback Relaxation amp Arousal HO3 Nerve Conduction ulnar nerve H10 EEG amp Hemispheric Asymmetry H11 Mirror Test EDA Sensory motor learning H12 EOG Saccades amp Displacement H13 EOG Visual Tracking H14 Ocular Fixation while reading H15 Ocular Fixation while viewing an image H16 Reaction Time H24 Habituation Bioengineering H02 Compartmental Modeling H20 Filtering H33 FFT Fast Fourier Transform 10 o T T C 1 o numan p 25 lessons targeted for Human Physiology ECG EEG EMG EOG amp EGG Pulmonary Function FEV 2 3 MVV PV Loops Airflow Blood Pressure Heart Sounds amp Korotkoff Sounds Nerve Conduction Electrodermal Activity GSR Pulse Reaction Time Temperature Stimulation amp Response Somatic Reflexes Gas Analysis O2 amp CO Colorimetry Tools Force amp Pressure Cardiac Output via bioimpedance Stroke Volume Auditory Somatosensory amp Visual Evoked Response Angle of Movement Acceleration Suitable for inquiry based active learning in 2 yr amp 4 yr programs medical schools and nursing pro
106. logy Neurophysiology BSL3 EEG Relaxation amp Brain Rhythms BSL4 Alpha Rhythms in the Occipital Lobe BSL11 Reaction Time H10 EEG amp Hemispheric Asymmetry H16 Reflexes amp Reaction Time Active Learning Biomedical Engineering H02 Compartmental Modeling H20 BME Filtering H33 FFT Fast Fourier Transform See page 43 45 for a description of all available lessons Increase your lab options with Airflow Transducer for Ex Phys SS52L p 33 Calibration Syringe 2 L AFT26 p 35 Cardiac Output Sensor SS31L p 29 0 amp CO Analysis Module GAS SYSTEM2 EA p 34 Finger Twitch Transducer SS61L p 30 Goniometer SS21L p 29 Reflex Hammer SS36L p 30 Stimulator BSLSTMB p 25 Transducer Accessory Pack BSLEXP TA p 42 18 T T C 2 gt F Suitable for inquiry based active learning in 2 yr amp 4 yr N 28 lessons targeted for Psychophys amp Neurophys ECG EEG EMG EOG amp EGG Autonomic Nervous System Auditory amp Visual Evoked Response Event Related Potential Startle Eye Blink Experiments Nerve Conduction Habituation Stroop Sensory Motor Learning Electrodermal Activity GSR Heart Rate Variability Visual Presentation System SuperLab amp E Prime Cardiac Output via bioimpedance Pre ejection Period PEP Automatic Continuous Noninvasive Blood Pressure programs medical schools and nursing programs Powerful set up and analysis tools make the BSL
107. m medium 23 33 cm and large 31 40 cm Finger cuff sensors are a consumable item and typically last 12 months based on 3 4 hours week Accurate noninvasive blood pressure values Easy to use Comfortable for subjects Real time continuous noninvasive BP Module display languages EN DE FR ES IT Order additional finger cuffs as RKNIBPDFINGER L RXNIBPDFINGER M or RXNIBPDFINGER S Module Dimensions 280 x 270 x 250 mm 11 x 10 6 x 9 8 in Weight 75 Kg 16 6 Ibs noninvasive blood pressure for animal Noninvasive Small Animal Tail Blood Pressure Systems Tail Cuff Sensor NIBP250 icis NIBP Amplifiers with built in pump A2 220 V automatically inflate the tail cuff to occlude the vessel in the tail of a rat or similar small animal and then slowly deflate the cuff when the inflation point is reached providing a linear drop in pressure A EM aiii tyi single control starts both the inflation and Systems include deflation cycles making the system very d Amplifier order NIBP250 or NIB200A operator friendly Amplifiers have two analog outputs for pressure Cuff Sensor 11 cm or request 9 5 or 13 cm and pulse waveforms plus gain adjustment to amplify or attenuate Restrainer medium or request small or large the pulse signal Systolic diastolic and mean BP values Analog outputs pressure 0 3 V DC Pulse 0 4 V DC NIBP250 Touchscreen LCD controls amp displays data for local Outpu
108. m with integrated heater Gas analysis module for CO and O measurements e Stimulus generation functionality e Digital control channels 8 Input 8 Output e Visual presentation options SuperLab E Prime MediaLab DirectRT Inquisit Support for the latest operating systems e New MP36 acquisition unit 24 bit resolution USB high speed Interface with all major amplifier and transducer manufacturers Use our ready made connectors or the custom kit Continuous product development Stimulator namic 1 The student friendly BSL System reduces setup time by up to 9096 so students collect excellent data and focus on scientific principles The multi level learning features of the BSL software let you control the material and method of each experiment you can even use the BSL for graduate programs and advanced research Use the 18 guided BSL Lessons for introductory concepts Choose from 45 PRO Lessons for introductory amp advanced concepts e Add analysis tools to existing Lessons e Let students develop experiment protocols e Modify a Lesson or incorporate existing lab procedures Easily create new experiments BSL lesson experiments are included in a number of the leading published Lab Manuals and have been successfully used to study e ECG e EDA GSR e Heart Sounds e Reaction Time e Force e EEG e Biofeedback e Nerve Conduction Respiration e EMG e Bioimpedance Cardiac Output Pulmonary Function Temperature e
109. max and min and use the noninvasive Cardiac Output Sensor to record stroke volume and cardiac output If flow signals are available record them simultane ously with pressure to examine vascular resistance and compliance Plot pressure versus flow to obtain P V Loops See the Frog Heart and Turtle Heart lessons on page 45 for refractory heartblock and vagal escape Muscular Record EMG to investigate the properties of skeletal muscle Record and display raw and integrated EMG sig nals overlap the signals for better correlation of the data EMG from a horse Measure strength and repeat trials for motor unit recruit ment summation and fatigue Demonstrate the treppe staircase phenome non Study the contractility of skeletal muscle with the force transducer and 1 9 31 lessons targeted for Animal amp Intro Human Phys stimulator The Frog Gastrocnemius les ECG EEG EMG EOG amp EGG son records threshold maximal response ee Temperature summation tetanus and fatigue Gas Analysis CO amp O2 pO Compound Action Potential i CON Use the new Nerve Chamber or an loimpedance ardiac Wutput existing chamber with the Low Voltage orce Stimulator SS58L page 25 to record Neurophysiology the compound action potential and Hemodynamics EF nerve conduction from the frog sciatic 4 Respiratory amp Pulmonary Function CAP in Overlap Mode i nerve Record action potentials from Reaction Time tu
110. mingham Southern College Boston University Bowling Green State University Brevard Community College Brigham Young University Bristol Heart Institute Bucknell University Cal State University Bakersfield Fullerton Los Angeles Northridge Sacramento Stanislaus California Lutheran University California Polytechnic Pomona San Luis Obispo Case Western Reserve Univ Catawba College Claremont McKenna College Clemson University Cleveland State University College of Holy Cross College of the Siskiyous Columbus State University International Abant Izzet Baysal Universitesi Acadia University Adnan Menderes niversitesi All India Institute of Medical Sciences American University College of Science amp Technology Beirut Ankara University Aston University Bar llan University Baskent University Berner Fachhochschule Brunel University Bryansk State Petrovsky University Camosun College Cardinal Tien Nursing School CEGEP de Sainte Foy CEGEP de Trois Rivi res Chang Gung Nursing Technology College Charles Sturt University Charles University China Medical College Christian Albrechts Universitat zu Kiel CHU Reims Chung Shan Medical University CNAM CNRS Coll ge Ahuntsic Coll ge de Sherbrooke College of the Fraser Valley Concordia University D Y Patil College of Pharmacy Daegu University Dicle University Dokuz Eylul University Eotvos Lorand University ENSSAT Cornell University
111. mouthpiece Gas Cylinder GASCAL AFT9 to remove airborne bacteria Calibration Gas Cylinder 496 CO 16 O2 Bal N2 not when measuring bi directional airflow for drug use not for inhalation Contains 560 Liters 2200 psig 70 F 21 C Please allow time for drop 35 Reusable Mouthpiece AFT9 shipment Use with the Airflow Transducer SS52L or the 35mm bacterial filter AFT4 to connect to the non rebreathing T valve AFT21 35 mm ID AFT9 Pack of 1 AFT9 10 Pack of 10 1 Regulator GASREG E Regulator output connects to GASSYS2 Calibration port via tubing Airflow Guide h em o Applications BIOPAC Part Airflow Transducers Human Animal respiration pulmonary function exercise physiology SS11LA med page 27 Pneumotachs See Lessons BSL11 BSL12 H29 H21 BSL15 H19 page 43 44 SS46L SS52L page 33 Calibration Syringes Use the AFT26 for increased precision See Lessons BSL11 BSL12 H29 H19 page 43 44 AFT6A page 34 AFT26 page 35 Calibration Gas Use to verify calibration settings GASCAL page 35 Interface tubes and ports Fit to specified ID OD sizes more port sizes available upon request AFT11B AFT11E AFT11F page 35 Facemask amp Strap Exercise physiology AFT10 and AFT10 S page 34 Facemask with Valve Exercise physiology pulmonary function metabolic rate BMR See H29 and H19 page 43 AFT25 page 35 Filters cc 3 AFT1 for SS11LA AFT4 for SS52L AFT1 page 34 AFTA page 35 Head Hea
112. n e Simple sensors validate transducer and signal connections e Multiple data display view data in industry standard formats X Y overlap clinical grids chart recorder oscilloscope standard curve dot display Adaptable lessons follow the lesson tasks or assign new tasks to suit your course requirements Adaptable protocols students can easily design experiments to develop and test their hypothesis with the BSL Intuitive interface with buttons and pop up menus Show or hide data channels and control size color label scale etc Add markers and measurements Data viewing options allow students to optimize display for signal type and include measurements markers grids etc for analysis or reporting e Data analysis and measurement tools extract baseline and experimental response values and compare them to normative values Professional data reports copy screen shots into lab reports and measurement values into statistical programs or create high quality printouts with clinical grids markers and full color Analysis options distribute the analysis software so students can analyze data outside the lab at home library etc Reporting and analysis options automatically paste measure ments and graphs to the journal or other programs Automated calibration optimizes the display settings for the subject s own signal Autosave feature for lessons includes student s name and lesson numb
113. nge Trans SSI2LA 27 Gas Analysis CO and O2 Analysis GASSYS2 34 Calibration Gas 35 Regulator 35 Goniometers SS20L SS24L 29 GSR Galvanic Skin Response see EDA Hardware 23 42 Table Hardware Used in Lessons 46 Headphones OUTIA 26 Heel Toe Strike SS28LA 29 Human Physiology 10 Interface Input BNC DSub 9 SS9LA and SS7OL 39 Input 3 5 mm DSub 9 BSLCBL5 39 Output BNC 3 5 mm BSLCBI 6 38 Output DSub 9 BNC OUT2 39 Custom Adapters SS KIT 39 Research Amplifier Adapter BSLCBL 4A 39 Trans Connector Interface BSL TCI series 39 Y adapter CBL204 39 Lab Manual BIOPAC 40 Lessons Summary 43 45 Micromanipulator MANIPULATOR 38 Manuals BIOPAC 40 Published 3rd party Manuals 8 Movement Accelerometers SS26LB SS27L 29 Finger Twitch Trans SS6 IL 30 Goniometers SS20L SS24L 29 Heel Toe Strike Trans SS28LA 29 Reflex Hammer Trans SS36L 30 MP36 Data Acquisition Unit 24 Multi lead ECG SS29L 27 Nerve Chambers NERVEI 2 38 Neurophysiology 18 Noninvasive Blood Pressure 32 33 Nursing Programs see Human Physiology 10 pH Probe Trans SS68L 31 Pharmacology 22 Platform Change PLAT 30 40 Pneumogram Trans sm animal SS67L 3 Power AC series 40 Pressure Trans SSI3L 27 Pulse Plethysmogram Trans SS4LA 26 Psychophysiology 18 Reflex Hammer Trans SS36L 30 Respiratory Effort Trans SS5LB 26 Safety Notice 23 24 Signal Processing Breadboard SS39L 30 Simple Sensor Transducers 26 40 S
114. nit 7 6 meter cable Pa Switches SS53L SS55L Use for remote event marking or to externally trigger data acquisition for psychophysiological response tests Monitor switch data as a digital input channel The following switches inter face with the I O port on the rear of the MP36 unit for digital input Hand Switch Digital SS53L n iilii m Dimensions 19 mm dia x 63 mm long Cable Length 2 meters Connector Type DSUB 2bf Foot Switch Digital SS54L Dimensions 69 mm wide 90 mm long 26 mm high Cable Length 1 8 meters Connector Type DSUB 25f Eight channel Marker Box Digital SS55L Independently mark events or provide responses on up to eight channels simultaneously Assign separate digital channels as event markers for individual analog input channels Easily customize the switch indicators by inserting parameters into the label sleeve on the front of the unit Dimensions 19 cm wide 11 cm deep 4 cm high Cable Length 2 meters Connector Type DSUB 25f See Lessons H11 H16 H24 H27 H30 pages 43 44 Finger Twitch Transducer SS61L N Use this transducer to record finger twitch responses from human sub jects receiving electrical stimulation using the HSTMOI page 28 The transducer conforms to the shape of the finger and attaches via a Velcro strap and tape Transducer Dimensions 14 6 cm long 0 50 cm wide Weight 69 ES Lesson H06 page 43
115. nsor SS31L p 29 0 amp CO Analysis Module GASSYS2 EA p 34 Temperature Transducer Immersible SS8L p 28 Transducer Accessory Pack BSLPHA TA p 42 JI e J an intro to bsi hardware The Biopac Student Lab offers a comprehensive line of electrodes transducers and accessories that work with the MP36 high performance data acquisition unit for a wide variety of applications on human animal organ or tissue preparations Electrodes are easy to use and transducers are durable and simple to handle Simple Sensor connectors detect which electrode or transducer is plugged into each channel and generate an on screen prompt if students mistakenly plug in the wrong transducer for a lesson The BSL software contains presets that simplify setup for each transducer and signal type offered i e Temperature Airflow Dissolved O and ECG EEG EMG Presets keep the hardware student friendly just connect and collect You can easily customize presets to match your protocol and existing transducers If you have legacy transducers that you d like to continue using you can select from more than 20 interface options for manufacturers like Narco Gilson Lafayette Harvard and Vernier see page 39 The BSL s interfacing flexibility can save a great deal of money and increases the system s usefulness BSL hardware can be ordered individually or as a system package Packages contain everything including consumable items necess
116. nsor connectors into the MP36 so you our custom interface kits see page 39 Airflow aid Med Flow SS11LA J Airflow Transducer for resting human amp light exercise Use the SS11LA to per form a variety of tests relating to airflow and lung volume integrate the airflow signal to obtain volume measurements ___ The pneumotach can be mounted on a camera tripod and has a clear remov able head for sterilization using Cidex or a dishwasher and replacement Connects to industry standard bacteriological filters AFT1 and disposable mouthpieces AFT2 For hygiene do not share disposable mouthpieces and disposable filters Flow Rate 300 liters min Dead space 93 ml Dimensions Head 82 5 mm diameter x 101 5 mm length Handle 127 mm long x 23 mm thick x 35 mm wide Ports 22 mm ID 30 mm OD The following consumable items are required for the SS11LA Airflow transducer to perform the pulmonary function lessons AFT1 Disposable Filter AFT2 Disposable Mouthpiece AFT3 Disposable Noseclip AFT6A Calibration Syringe See page 34 for Airflow Accessories Available in bulk low cost quantities for student accessory packs Replacement Airflow Head RX117 The RX117 is a sterilizable replacement transducer head for the SSIILA Airflow Transducer See Lessons BSL12 BSL13 BSL15 H29 H19 pages 43 44 See High Performance Air Flow options on page 35 Variable Range Force Transducer SS12LA Use the SS12LA force transducer
117. nterference Generally for biopotential recordings one each of LEAD110S W LEAD110S R and LEAD110 are required LEAD110 works best as a ground or reference lead LEAD110 Unshielded Electrode Lead Black 1 m LEAD110A Unshielded Electrode Lead Black 3 m LEADI10S R Shielded Electrode Lead Red 1 m LEADI10S W Shielded Electrode Lead White 1 m ne Posi Lead LEAD120 This l meter lead with Touchproot connector works with the reusable EL120 electrode page 38 Snap the electrode into place and then plug the lead in via the SSILA adapter LEAD120 R Red Cable LEAD120 W White Cable Clip Leads LEAD140 Series Use these leads to interface with silver wire platinum recording electrodes or to connect directly with an animal preparation Choose from gt three styles electronic test x clip alligator clip and toothless io clip Leads terminate with a Touchproof connector to interface with the SSILA shielded electrode adapter or BSLCBL8 or BSLCBL9 LEAD 140 Alligator Clip Lead LEAD141 Toothless Alligator Clip Lead LEAD 142 Electronic Test Clip Lead spring loaded Orie High oe Cables The fully shielded high impedance electrode interface cable permits high resolution recording of extracellular signals from small preparations using reusable electrodes EL250 EL350 or EL450 series pages 37 38 your own custom Ag AgCl electrodes or glass microelectrodes The 2 meter cable terminates w
118. ntion of disease e See Compliance amp Ratings on page 24 for details T o C e aT Data Acquisition Units MP36 and MP45 The data acquisition unit is the heart of the Biopac Student Lab System An MP36 or MP45 is included with each BSL System order The unit connects to your computer using a USB port The MP36 has four universal analog input channels while the smaller MP45 has two The inputs are human safe certified to IEC60601 1 and can record data from a wide range of signal sources including biopotential signals such as ECG EEG EMG and EOG transducer signals such as force pressure temperature pH and bioimpedance and microelectrode signals from intra and extracellular sources The BSL System software controls the MP36 45 hardware to create a comprehensive teaching system The teaching system centered around dozens of lesson experiments can be applied to complement a wide range of curriculum from human physiology to biomedical engineering Powerful measurement tools help extract meaningful data The BSL System Software can automatically calculate many measurements from raw data such as heart rate systolic and diastolic blood pressure lung volume etc See the BSL Software overview pages 2 7 to learn more about the power and flexibility of the BSL System Additional Features for MP36 Only Built in control features support low and high voltage stimulation trigger pulses sound outp
119. oftware Overview 2 7 Sound Detection Headphones OUTIA 26 Microphone Physiological Sounds 551 7L 28 Microphone Speech Frequency SS62L 30 Stethoscope Electronic Trans SS30L 28 Tubephone OUTIOI 31 SS Series Simple Sensor Transducers 26 40 Stimulation Clip Leads BSLCBL 7 11 12 38 Human safe Electrode HSTMOI 28 Needle Electrodes for animal ELS TM2 38 Nerve Chambers NERVE1 2 38 Stimulators BSLSTMB and SS58L 25 Stimulus Presentation SuperLab STP35W 32 Strip Electrodes 37 Stroboscope TSD122 32 SuperLab System STP35W 32 Switches Digital Switches SS53L SS55L 30 Hand Switch analog SSIOL 26 Temperature Sensors Fast response Thermistor SS6L 26 Waterproof or Liquid Immersion 55 L S58L 28 Tissue Bath Stations amp Accessories 33 Transducers SS Series 26 40 Transducer Accessory TA Packs 42 47 Toxicology 22 Ultimate System 9 Upgrade Customer Loyalty Program 40 USB Interface CBLUSB 40 Variable Assessment Trans SS43L 30 Y adapter CBL204 39 www biopac com Q Biopac Student Lab users A partial list of satisfied Biopac Student Lab users follows If you would like a list tailored to identify users in your area or your application of interest contact BIOPAC at info biopac com United States Alma College Augusta State University Austin Peay State University Bakersfield College Barry University Baylor College of Medicine Baylor University Bellarmine University Bethel College Bir
120. ography Cardiac Output H22 Visual Evoked Response VER H23 Signal Averaged ECG H24 Habituation H25 BME Signal Processing 8 circuits amp d d Page 44 44 44 44 45 H26 BME Signal Processing Il ECG R Wave Detector 43 H27 Facial EMG H28 Reflex Response patellar tendon H29 Basal Metabolic Rate H30 Stroop Effect H31 Prepulse Inhibition H32 Heart Rate Variability Analysis H33 BME FFT Fast Fourier Transform H34 Electrogastrogram from human stomach H35 Range of Motion Sit amp Reach H36 Muscular Biofeedback auditory visual touch AQI Frog Pith amp Prep A02 Frog Gastrocnemius A03 Frog Sciatic Nerve A04 Frog Heart A05 Visceral Smooth Muscle A06 Cockroach Ventral Nerve A07 Qo Principle Dissolved O2 Goldfish A08 Action Potential in Earthworm A09 Properties of Turtle Heart Cardiac Muscle All Resting Potential Crayfish Muscle Al4 Central Pattern Generator hornworm pupa AIS Earthworm Smooth Muscle interface included probe required tissue bath required 44 43 44 44 44 45 43 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 trequires Crawdad CD ROM Lab Manual Basic x x KX 0X OX x Xx m Adv x x KK KKK KK KKK KR XK x x x KK KR OX Ult x Ke KKK KR KR KR KR KK KR KK KK KM x KKK XN OX XN OX x KX KK Nox OX xt X Human x Ke KK OX X x wm KX 0X x Animal x KX KM x wm KX RK x x xX OK X Biology XO X 0X 0X 0
121. ood pressure Determine pulse wave velocity For advanced studies use the noninvasive cardiac output sensor to record stroke volume and cardiac output File Edit Transform Displ Respiratory amp Pulmonary Function EFE NES ren The BSL provides an excellent introduc tion to volumes and capacities respiratory flow rates breathing mechanics and venti lation Display and or print a clinical grid on the data for effective interpretation and 106 19 11327 seconds training The software guides the student Ready Grid Off in measuring FVC and in calculating FEV and MVV The airflow transducer is hand held lightweight easy to clean and very easy to use Take measures before Cardiac output and stroke volume during and after exercise to study amp Biopac Student Lab DavidMP35 L12 loj xi Fie Edit Display Lessons Help ventilation and heat exchange The new Gas Analysis module provides online measures of CO and O levels for Respiratory Exchange Ratio O2 Consumption and Basal Resting Metabolic Rate lessons Non rebreath Er Lesson 12 Pulmonary Function Volumes and Capacities File name David L12 T Friday September 19 2003 x T oe ing T valves air chambers facemasks and tubing options provide setup Pulmonary volume options to suit any protocol Muscular Record EMG data to investigate the properties of skeletal muscle Record and display raw and
122. orm a wide variety of applications targeted for biomedical engineering Use BIOPAC lessons or easily create your own experiments with the BSL PRO software included with each system Order the core package or select items la carte See BSL Hardware page 23 for all available transducers electrodes and accessories Biomedical Engineering Core BSLBME W Win or BSLBME M Mac Basic BSL System BSLBSC p 8 Airflow Filters 10 pk AFT1 p 34 Airflow Mouthpieces 10 pk AFT2 p 34 Airflow Nose Clips 10 pk AFT3 p 34 Airflow Transducer SS11LA p 27 BP Cuff Transducer SS19LA p 27 Calibration Syringe 600 ml AFT6A p 34 Electronic Stethoscope Transducer SS30L p 28 Hand Dynamometer SS25LA p 27 Hand Switch SS10L p 26 Headphones OUT1A p 26 Pulse Transducer SS4LA p 26 Signal Processing Breadboard Lab SS39L p 30 Perform 29 or more lessons with this core package Muscular BSL1 Standard amp Integrated EMG BSL2 Motor Unit Recruitment amp Fatigue H07 EMG Contractions Active Learning H27 Facial EMG H34 EGG Electrogastrogram H36 Muscular Biofeedback Cardiovascular BSL5 Components of the ECG Lead Il BSL6 Leads Il Ill amp Einthoven s Law BSL7 ECG amp Pulse BSL16 Blood Pressure amp Korotkoff Sounds BSL17 Heart Sounds amp Cardiac Events H08 Dive Reflex Active Learning H23 Signal Averaged ECG H32 Heart Rate Variability Pulmonary Function BSL12 Pulmonary Function Vol amp Capacities BSL
123. ow Transducer to calibrate a respiration sensor designed to monitor thoracic circumference EEG Spectrum E R L EETA Emiri sc Freq 1e30Hz sc vswe 18 82 x Li EEG Spectrum Magni tude Human amp Animal Physiology The wide range of 4096 point FFT DAPET E P REE a E ae pus Pad with zeros C Pad with last point v Remove mean IV Magnitude dB Linear a VM zr Phase Show modified input ammini human and animal annin physiology experiments D 0000 5000 provide a powerful tool for teaching students FFT dialog and EEG spectrum the best technique and methodology for making a measurement Each experiment demonstrates fundamental physiological concepts and edu cates students in the setup recording and analysis process Physiology basics are clearly explained See pages 10 13 for details Programming Options Students can create their own programs to control the MP36 hardware with the BHAPI hardware application program interface Students can also develop their own analysis programs to read the BIOPAC file format with the ACKAPI software application program interlace See page 24 for details Physiological Control Systems amp Compartmental Analysis Implement simple experiments illustrating physiological control systems and com partmental analysis with the BSL System The students can observe signal changes Biopac
124. potential 45 ETE d Wg ul a k wo L a m m 8 i oum a o n E j I BEI i 4 i a a Lu 5 EE i E RE xd RESP amp PULM page 43 NEUROPHYS pages 43 44 EX PHYS page 44 ANIMAL page 45 46 lesson hardware guide Us a fra IO P7 P OPrCILA Fe A SIr 10 VIC P a CKc AQ Jt a harc Wwe al U BSLI EMG BSL2 EMG Il BSL3 EEG BSL4 EEG Il BSL5 ECG BSL6 ECG Il BSL7 ECG amp Pulse BSL8 Respiratory Cycle BSL9 GSR amp Polygraph BSL10 Electrooculogram EOG BSL Reaction Time BSL I2 Pulmonary Function BSLI3 Pulmonary Function Il BSL 4 Biofeedback BSL I5 Aerobic Exercise Physiology BSL I6 Systemic Blood Pressure BSLI7 Heart Sounds BSL20 Spinal Cord Reflexes HO 12 Lead ECG H02 BME Compartmental Modeling H03 Nerve Conduction Velocity H04 Blood Pressure Response to Straining Exercise H05 Wingate Test WAnT H06 Finger Twitch H07 EMG Active Learning H08 ECG Dive Reflex Active Learning H09 Auditory Evoked Potential AEP HI0 Hemispheric EEG HII Mirror Test Sensory Motor Learning amp EDA HI2 Saccades EOG HI3 Tracking EOG H14 Fixation EOG 3 lead HI5 Fixation Il EOG 6 lead HI6 Reflexes amp Reaction Time Active Learning HI Biomechanics HI8 Exercise Phys Continuous Noninvasive BP HI9 VO amp RER H20 BME Filtering H21 Impedance Cardi
125. rans SS43L p 30 Stimulator BSLSTMB p 25 SuperLab Package STP35 p 32 Finger Twitch Transducer SS61L p 30 Stim Electrode for Humans Transducer Accessory Pack HSTMO01 p 32 BSLPSY TA p 42 20 T o C s gt E J 60 lessons targeted for Human amp Animal Physiology Signal Analysis amp Processing ECG EDA GSR EEG EGG EMG amp EOG Force Pressure Strain Flow Temperature Sound Light Filters FIR amp IIR Instrumentation Design Respiratory System amp Pulmonary Function Bioimpedance Cardiac Output amp Blood Flow Biomechanics Angle Acceleration Distance Velocity Transducers amp Calibration Physiological Control Systems Compartmental Modeling Blood Pressure amp Heart Sounds Gait Analysis Chart Overlap Scope amp X Y Displays Spectral Analysis amp Histograms Export to MatLab LabVIEW and MS Excel Word Suitable for inquiry based active learning in 2 yr amp 4 yr programs medical schools and nursing programs engineering During each BIOPAC laboratory exercise students follow detailed procedures that are designed to demonstrate principles of biophysics and biological measurement Student feedback on the laboratories has been phenomenal with the hands on experiences motivating the students in a way that no lecture only course can IEEE Engineering in Medicine and Biology July August 2003 Vol 22 No 4 pg 106 Signal
126. re Wave Oscillator Lab 5 Notch Filter for 60 Hz Rejection Lab 2 Instrumentation Amplifier Lab 6 ORS Detection Band Pass Filter Lab 3 High Pass Active Filter Lab 7 ORS Detection Absolute Value Circuit Lab 4 Active Gain Block Lab 8 ORS Detection Low Pass and Low Pass Filter Filter and Overall System Test Combine modules to build a complete ECG Signal Processor Optional Signal Processing Cable SS60L Use this signal cable to record additional channels with the SS39L Signal Processing Breadboard See Lessons H25 H26 page 45 Differential Pressure SS40L SS42L These transducers interface a variety of small animal breathing circuits to the MP36 for air pressure monitoring The transducers are extremely sensitive and come in three ranges to suit a number of different applications Included with each SS46L SS52L page 33 Range SS40L 2 5 cm H 0 SS41L 12 5 cm H20 SS42L 25 0 cm H20 Dynamic Response 100 Hz Connection ports ID 3 mm to 4 5 mm tubing accepted Dimensions 8 3 cm high x 3 8 cm wide x 3 2 cm deep Weight 76 grams Variable Assessment Transducer SS43L Use this handheld slide control transducer to record subjective responses for a variety of different stimuli Use multiple transducers to allow several people to simultaneously answer the same question or otherwise respond to stimuli Easily customize the response scale by inserting parame ters into the scale sleeve on the front of the u
127. rodes or needle electrodes Number of Channels 2 Impedance Zo and dZ dt Operational Frequency 100 kHz Outputs Impedance Zo 0 100 ohms dZ dt 20 ohms sec Configuration Tetrapolar 4 Electrodes Excitation 400 uA RMS constant current See Lesson H21 page 43 30 ran Connect directly to the MP36 Data Acquisition Unit Reflex Hammer SS36L This is a classic reflex hammer with a transducer attached to perform reflex measurements It uses a Taylor Hammer the most common type of reflex hammer used by doctors and incorporates elec tronics to record the time and the relative strength of the impact This allows students to measure how much ol an ini is needed to elicit a response Signal Processing Breadboard SS39L The Bioengineering Breadboard Lab consists of circuitry hardware and lessons with schematics and design notes that demonstrate a very important subset of circuit design for recording and pro cessing physiological signals Includes electrode signal lead interface Use with SS60L cables to record circuit performance on more than one chan nel Students will use the MP36 and BSL PRO software to evaluate their designs Included Hardware 1 Breadboard 1 Power Signal Cable includes fuses with built in automatic reset 1 Parts kit including op amps capacitors diodes resistors and jumper wires as required to complete projects Lesson Modules Lab 1 Squa
128. s ELPAD 10 pk Stethoscope SS30L and Clench Force bulb Transducer SS56L These hardware suggestions will enable you to perform a variety of lessons for human subjects Use BIOPAC lessons or easily create your own experiments with the BSL PRO software included with each system Order the Basic System or select items a la carte If you start with the Basic System hardware upgrades are available to create Advanced or Ultimate Systems See BSL Hardware page 23 for all available transducers electrodes and accessories Basic System BSLBSC W Win or BSLBSC M Mac BSL Lab Manual MANBSL4 p 40 Abrasive Pads 10 pk ELPAD p 36 Data Acquisition Unit MP36 p 24 Electrode Lead Sets 2x SS2LB D 25 USB Cable CBLUSB p 40 BSL Software BSL 4 with Lessons amp PRO Disposable Electrodes 100 pk EL503 p 37 Power Transformer AC300A p 40 Perform 19 or more lessons with the BASIC System Cardiovascular Neurophysiology Muscular BSL5 Components of the ECG Lead Il BSL3 EEG Relaxation amp Brain Rhythms BSL1 Standard amp Integrated EMG BSL6 Leads l Il Wl amp Einthoven s Law BSL4 Alpha Rhythms in the Occipital Lobe HO7 EMG Contractions Active Learning H08 Dive Reflex Active Learning BSL10 Eye Movement saccades amp Fixation H27 Facial EMG H23 Signal Averaged ECG H10 EEG amp Hemispheric Asymmetry H34 Electrogastrogram from human H32 Heart Rate Variability H12 EOG Saccades amp Displacement Bioengineering H13 EOG Visual Tracking H2
129. t cables pressure cable and pulse cable analysis and storage of Use as a stand alone system or Interface cables to BIOPAC or third party A D hardware interface to BIOPAC or third party A D hardware USB 1 1 Users Manual compatible flash memory port and SD card slot Optional Tail Heater TAILHEATA 110 V or TAILHEATB 220 V NIBP200A Amplifier for use with Tail Cuff Sensor k h Integrated Tissue Bath amp Components Heater System ITBS1 00 e x Bath specify 20 ml 30 ml or 50 ml x Reservoir 800 ml x Integrated Heater 1600 ml volume 20 44 C x Circulator Pump 15 W 500 ml min x Micrometer fits BIOPAC transducers e 2 x Triangle Tissue Clip Stainless Steel reorder as RXCLIP TRI 2 x Tissue Clip Stainless Steel reorder as RXCLIP x Tissue Holder Stainless Steel reorder as RKHOLDER S A modular durable solution for your lab Features include Jacketed bath and reservoir in a range of volumes ntegrated heating circulator program mable temperature range 20 44 C e 500 ml min circulation flow Movable micrometer transducer assembly 1 x 3 way Rotary Valve User friendly display and controls x Power Supply specify 110 V 60 Hz or 220 V 50 Hz One switch control of fill drain cycle See Lessons A05 A15 page 45 H Microprocessor control en F Low level alarm for water temperature Acrylic robust bath e Small lightweight setup
130. tMP35L 7 LO Monday September 22 2003 09 08 5T AM the latest technology for continuous non 4 ECG and pulse tolic pressure Students can also utilize invasive BP recordings Use the noninva sive Cardiac Output Sensor SS31L page 29 on human and animal subjects to record stroke volume and cardiac output By measuring continuous mean arterial pressure simultaneous with flow cardiac output students can examine vascular resistance Biopac Student Lab ElieMP35 L16 lol xl File Edit Display Lessons Help Overlap Split E 121 67263 mm 1 bom HBE ce Respiratory amp Pulmonary Function Students can record the pattern of breathing as well as perform compre hensive cardiopulmonary tests There are lessons for determining tidal volumes and lung capacities S FEV1 23 and MVV plus full gas analysis studies 0 00 320 EM 16 Blood Pressure B File name ElieMP35 L16 T hooda September 22 2003 E 4 Gas Analysis ux Students can use the new gas analysis system File Edt Transform Display window MP30 Help laj x DEES ams aE to monitor expired CO and O levels for detailed metabolic studies with human and animal subjects Take measures to study ventilation and heat exchange Use the Dissolved O probe and lesson to measure the oxygen consumption of a goldfish Chambers facemasks and tubing accessor ies provide setup options for any protocol Neuroph
131. tem Order the core package or select items la carte See BSL Hardware page 23 for all available transducers electrodes and accessories Exercise Physiology Core BSLEXP W Win or BSLEXP M Mac Basic BSL System BSLBSC p 8 Airflow Filters 10 pk AFT1 p 34 Airflow Mouthpieces 10 pk AFT2 p 34 Airflow Nose Clips 10 pk AFT3 p 34 Airflow Transducer SS11LA p 27 BP Guff Transducer SS19LA p 27 Calibration Syringe 600 ml AFT6A p 34 Electronic Stethoscope Transducer SS30L p 28 Hand Dynamometer SS25LA p 27 Hand Switch SS10L p 26 Headphones OUT1A p 26 Pulse Transducer SS4LA p 26 Respiratory Effort Transducer SS5LB p 26 Temperature Transducer SS6L p 26 Surgical Tape TAPE1 p 36 Perform 27 or more lessons with this core package Muscular BSL1 Standard amp Integrated EMG BSL2 Motor Unit Recruitment amp Fatigue H07 EMG Contractions Active Learning H27 Facial EMG H34 EGG Electrogastrogram H36 Muscular Biofeedback Cardiovascular BSL5 Components of the ECG Lead Il BSL6 Leads Il Ill amp Einthoven s Law BSL7 ECG amp Pulse BSL16 Blood Pressure amp Korotkoff Sounds BSL17 Heart Sounds amp Cardiac Events H05 WAnT Wingate Test H08 Dive Reflex Active Learning H23 Signal Averaged ECG H32 Heart Rate Variability Pulmonary Function BSL8 Respiratory Cycle BSL12 Pulmonary Function Vol amp Capacities BSL13 Pulmonary Flow Rates FEV and MVV BSL15 Aerobic Exercise Physio
132. the burden on department budgets sell these student accessory packs through your school bookstore Each pack includes disposable one use only items required to run BSL Lessons 60 x Disposable Electrodes EL503 1 x Nose Clip AFT3 1 x Disposable Mouthpiece AFT2 8 x Abrasion Pads ELPAD 1 x Disposable Bacterial Filter AFT1 8 x EDA Electrodes EL507 Standard Syringe AFT6A Use the 0 6 liter calibration syringe with the SS11LA Airflow Transducer or the GASSYS2 incorporates a 22 mm OD 15 mm ID coupler use the AFT26 for increased calibration precision T Valves AFT23 Low cost non rebreathing T valve 35 mm OD includes 8 replacement valves Fits AFT13 filter amp mouthpiece set AFT22 Interfaces with SS11LA Airflow Transducer and AFT7 tubing via the AFT11E coupler Suitable for static applications with low to medium flow rates Requires AFTI and AFT2 for proper operation All ports 22 mm OD includes 22 mm OD coupler sons 129 and H19 page 45 IS I127 and fly page Reusable Mouthpiece AFT8 Autoclavable Use with the SS11LA Airflow Transducer to reduce the cost of disposable parts 30 mm ID AFTS8 Pack of 1 AFT8 10 Pack of 10 Disposable Adult Facemask AFT10 This disposable facemask connects to 22mm breathing circuits 22mm ID 25mm OD Connects directly to the AFT1 AFT22 non rebreathing T valve or SS11LA Airflow transducer via tubing AFT7 and two couplers AFT11B and AFT11E Includes hook ring to se
133. timal for measuring quick movements such as swinging a tennis racket Range Output SS26LB 5 g SS27L x50 g Bandwidth DC 500 Hz 3 dB Dimensions SS26LB 16 mm long x 17 mm wide x 8 mm high SS27L 33 mm long x 28 mm wide at base x 19 mm high Heel Toe Strike SS28LA Use this transducer to record heel and toe strike activity as the subject walks The heel toe strike data is recorded as a single channel the heel strike generates a negative deflection and the toe strike results in a positive deflection Two force sensitive resistors FSR attach to the sole of a shoe use two SS28LA transducers to simultaneously record from both feet 20 Nominal Contact Force 200 g to indicate heel toe strike Attachment TAPE1 TAPE2 FSR Dimensions 18 3 mm wide x 0 36 mm thick x 30 cm long FSR Active Area 12 7 mm dia Cable Length 76 meters Cardiac Output Sensor SS31L Measure cardiac output noninvasively using electrical bioimpedance techniques the sensor is suitable for human and animal measurements Use the sensor to record stroke volume and CO before and after exercise or during a psychophysiology test The sensor provides a noninvasive powerful cardiovascular hemodynamic demonstration that allows students to see the real time changes in stroke volume and cardiac output Typically used with disposable bioimpedance strip electrodes EL506 on page 37 but can function with spot or band electrodes reusable elect
134. ting from BME Step two degrees of freedom Model mechanical systems demon strate principles of biomechanical resonance or inertial navigation acceleration velocity and position or convert gravity vectors from Tri Axial Accelerometers into associated tilt angles for use in ergonomic evaluations See page 16 for details Instrumentation Design The new signal processing breadboard allows students to build and test real world signal processing circuit mod ules and then verify their performance against mathemati cal simulation using graphical comparisons Students can combine circuit modules collect physiological signals and then analyze the results Each circuit module consti tutes an important subset of circuit design when record ing and processing physiological signals The BSL system is used like an oscilloscope to make measurements for Circuit simulation circuit module evaluation Interface with Existing Equipment The BSL System offers over 60 industry standard transducers Further the BSL System interfaces with other major amplifier and transducer manufacturers encompassing the most commonly used biomedical engineering instruments and sensors by using a wide variety of interface connectors and cables Choose from 18 ready made interface connec tors or build your own with the custom interface kit medical engineering The following hardware suggestions will enable you to per f
135. um A A Online Help Quick Guide Tutorials searchable manuals pdf PRO Lessons os od QENEENENEEMMs Video Help movie clips of procedures and sample data Data Examples files for male and female subjects Web Link use your active browser to link to the full spectrum of support at www biopac com Desktop Streaming like having an on site rep this option allows remote viewing and mouse control so we can see your data and review your setup for targeted Tech Support Phone Support qualified BSL Specialists provide telephone support Lab Manuals use the BSL Laboratory Manual or choose from major published A amp P Lab Manuals System Level Solutions e Hardware Data acquisition unit transducers amp electrodes e Software Building block structure for guided lessons to open ended discovery Advanced Programming Options Application Programming Interfaces E available to control MP36 hardware or access BIOPAC data files D peas Curriculum Library amp Extensive support materials Grant friendly solutions Recognized by the NSF NIH The Whitaker Foundation and most major grant foundations Worldwide customer base Thousands of users Multi lingual support English Spanish French Chinese Japanese Russian Italian State of the Art Technology e Students learn real world skills using clinical recording techniques e Industry standard transducers Over 60 currently available Tissue bath stations Modular syste
136. ut and digital I O options Use the BSLSTMB Stimulator for human subjects use the MP36 s built in low voltage stimulator with OUT3 for animal studies The system can also record from and send digital trigger information to other software and devices such as SuperLab and E Prime switches and relays The fast processor coupled with a variety of triggering functions allows the system to be used like an oscilloscope chart recorder or X Y monitor BSL System Safety Compliance amp Ratings BIOPAC MP36 and MP45 Systems and accessories are safe for use on human animal organ and tissue preparations The MP36 45 Systems were tested by an accredited product safety testing and certification agency and classified as Class Il Type BF equipment The MP36 45 Systems comply with applicable requirements for the following product and safety standards e CE mark e EC 60601 1 e EN 60601 e EMC IEC 60601 1 2 C e UL 60601 1 e CAN CSA C22 2 No 601 1 M90 e JIST 1001 Application Programming Interface Student software developers can use BIOPAC API options to design and execute their own programs to control BIOPAC hardware or analyze data in other programs BIOPAC Hardware API BHAPI Control the BIOPAC MP3X acquisition unit Use API functions to acquire data acquire at different sample rates set triggers get the MP3X status use the Analog Output channels or the Digital I O e Reference manual and s
137. ware suggestions will enable you to perform a wide variety of applications targeted for human physiology Use BIOPAC lessons or easily create your own experiments with the BSL PRO software included with each system Order the core package or select items la carte See BSL Hardware page 23 for all available transducers electrodes and accessories Human Physiology Core BSLHPY W Win or BSLHPY M Mac Basic BSL System BSLBSC p 8 Hand Dynamometer SS25LA p 27 BP Cuff Transducer SS19LA p 27 Electronic Stethoscope Transducer SS30L p 28 Airflow Transducer SS11LA p 27 Airflow Filters 10 pk AFT1 p 34 Airflow Mouthpieces 10 pk AFT2 p 34 Airflow Nose Clips 10 pk AFT3 p 34 Calibration Syringe 600 ml AFT6A p 34 Perform 25 or more lessons with this core package Muscular BSL1 Standard amp Integrated EMG BSL2 Motor Unit Recruitment amp Fatigue H07 EMG Contractions Active Learning H27 Facial EMG H34 EGG Electrogastrogram H36 Muscular Biofeedback Cardiovascular BSL5 Components of the ECG Lead Il BSL6 Leads Il Ill amp Einthoven s Law BSL16 Blood Pressure amp Korotkoff Sounds BSL17 Heart Sounds amp Cardiac Events H08 Dive Reflex Active Learning H23 Signal Averaged ECG H32 Heart Rate Variability Pulmonary Function BSL12 Pulmonary Function Vol amp Capacities BSL13 Pulmonary Flow Rates FEV and MVV Neurophysiology BSL3 EEG Relaxation amp Brain Rhythms BSL4 Alpha Rhythms in
138. with the cardiac cycle H01 12 LEAD ECG Record a 12 lead ECG and observe changes in the frontal plane vectors throughout a cardiac cycle H08 ECG DIVE REFLEX ACTIVE LEARNING Subjects immerse their face in cold water and record the change in heart rate that occurs to investigate the physiological reason for the observed response H21 IMPEDANCE CARDIOGRAPHY Noninvasively record and measure stroke volume and heart rate data and correlate with cardiac output H23 SIGNAL AVERAGED ECG Record ECG data under different experimental conditions and perform a Signal Averaged ECG recording for each segment of data MUSCULAR BSL LESSON 1 EMG I H07 EMG ACTIVE LEARNING Investigate the electrical activity of different muscles as they contract with varying degrees of force and design experiments by selecting muscles to record from and creating activities those muscles will perform H27 FACIAL EMG Record EMG response on the corrugator supercilii amp zygomaticus major muscles H34 ELECTROGASTROGRAM Record electrical activity through stomach muscles EGG and note the power and frequency of contractions at rest and after eating RESPIRATORY amp PULMONARY FUNCTION BSL LESSON 8 RESPIRATORY CYCLE I Record chest contraction amp expansion and ventilation then correlate respiration changes with ventilation to examine the effects of cerebral influence and chemoreceptor influence on the medullary control centers
139. y receives sensory input and integrates the information before processing it The system records and displays raw EEG alpha wave and alpha RMS activity Lesson Update See www biopac com for lesson additions and product updates 43 RESP amp PULM page 43 NEUROPHYS pages 43 44 ANIMAL page 45 44 BSL LESSON 9 GSR amp POLYGRAPH EDA Record changes in respiratory rate heart rate and electrodermal activity skin conductance to become familiar with the stan dard physiological measures recorded by a polygraph and study the effects of cognitive behavior and emotion BSL LESSON 10 ELECTROOCULOGRAM EOG I Record horizontal and vertical eye movement to demonstrate eye fixation and tracking Students perform a number of tasks that allow them to record the duration of saccades and fixation BSL LESSON 11 REACTION TIME I Subject hears two schedules of clicks through headphones and reacts by pressing a pushbutton hand switch as quickly as possible to demonstrate the effect of learning and physio logical processes on reaction times BSL LESSON 14 BIOFEEDBACK Record ECG heart rate and electrodermal activity and try to influence heart rate and EDA GSR to control the position of a bar graph to demonstrate the principles of biofeedback training for relaxation purposes BSL LESSON 20 SPINAL CORD REFLEXES Record and examine properties of spinal neuromuscular reflexes commonly tested in physical
140. ysiology Study EEG under a variety of conditions to explore relaxation and brain rhythms the software can filter and display each rhythm separately Alpha Beta Delta and Theta Study Alpha rhythms in the occipital lobe reaction times and hemispheric asymmetry Use the system to demonstrate changes in parasympathetic and sympathetic tone Add EOG ocular signal to study eye movement saccades tracking angular displacement or ocular fixations Use the stimulator to study evoked response auditory visual or somatosensory Record reaction time and measure nerve conduction veloc ity The system samples quickly enough to easily record spontaneous nerve activity from small animals and insects Digestive System Use the system to record gastric signals in humans and animals or monitor isolated intestinal gut strips in a tissue bath experiment Monitor the EGG Electrogastrogram before and after food digestion Examine gastric slow wave propagation peristaltic slow wave propagation and gastrointestinal motility Membrane potential using crawfish and glass microelectrodes Cellular Biology Use the BSL hardware with suitable glass microelectrodes to demonstrate membrane potential of crawfish These experiments demonstrate the principle of homeostasis and serve as a good introduction to electrophysiology recording techniques The system will also work with the popular Crawdad CD ROM Lab Manual for Neurop