Home
Business/Home GSM
Contents
1. Outer Alarm Siren Volume 110 dB Working Condition Temperature 10 C 40 C Humidity lt 90 rh Wireless Gap Detector Door Window Contact Power Supply DC12V inner 12V battery Static Current lt 20 mA Transmission Current lt 15mA Transmission Frequency 315 433MHZ 0 5MHZ Transmission Distance No obstacle 80m Internal Distance 15 mm Working Condition Temperature 10 C 40 C Humidity lt 90 rh Wireless P IR Detector Power Supply DC9V inner 9V battery Static Current lt 100 mA Transmission Current lt 20mA Transmission Frequency 315 433MHZ 0 5MHZ Transmission Distance No obstacle 80m Detective Speed 0 3 3m s Detective Distance 5 12m Detective Range Horizontal 110 Vertical 60 Working Condition Temperature 10 C 40 C Humidity lt 90 rh Remote Control Power Supply DC12V inner DC12V battery Transmission Current lt 15mA Transmission Frequency 315 433MHZ 0 5MHZ Transmission Distance No obstacle 80m
2. light OUTPUT 3 If the host speaker is in working mode the output 3 will be on showing you can talk or speak to scene 4 About RELAY light If 2 outputs of the relay on the host is connected the relay light will be on otherwise will be off 5 About SIREN light If the host siren is sounding the siren light will be on 6 About MONINTOR light If the monitor function is opened the monitor light will be on If the monitor function is closed the monitor light will be off Standard components and optional available components The following sensors can be optional Additional wireless products PIR Detectors Smoke Detectors h ce ec Ly e Remote Controls Door Window gap sensors Panic Buttons J j ve LPG Gas Detectors Optional sensors detectors are packed separately It includes remote controllers wireless PIR wireless gap sensor wireless gas detector wireless smoke detector panic button baluster etc You may purchase according your specific requirements Typical house configuration Doorwindow Smoke Detector Rj External Sirens Garage PIR Movement Detectors TECHNICAL PARAMETER 1 Static current 20mA 2 Power 9V 12V DC 3 Working temperature 20 C 85 C 4 GSM850 900 1800 1900MHz band 5 Receiving code ASK 6 Frequence 315 433 868 915MHZ 7 wireless distance 100 M 8 wireless detectors 16 9 wire detectors 3
3. the alarm message is Wireless Activated 04 If the fifth wireless detector is triggered the alarm message is Wireless Activated 05 If the sixth to sixteen wireless detector is triggered the alarm message is Wireless Activated i 1 6 16 If the wired detector is triggered the alarm message is Wired Activated 1 i 1 3 for port 1 to 3 alarm Users can send commands to the host to change the alarm content The alarm message cannot be more than 24 letters 123456 8 Front door open to save first group message into the host when first wireless detector is triggered 123456 82 Middle door open to save the 2 SMS into the host when the 2 wireless detector is triggered 123456 83 Back door open to save the 3 SMS into the host as third wireless detector is triggered 123456 84 Front window open to save the 4 SMS into the host as fourth wireless detector is triggered 12345 6 85 Back window open to save the 5 SMS into the host as fifth wireless detector is triggered 12345648 6 Middle window open to save 6 SMS into the host as sixth sixteenth wireless detector is triggered 12345648 74Kitchen is on fire to save 7 SMS into the host as port 1 to 3 wired detectors are triggered How to operate when the host is alarming In normal usage if the host is in disarm status the signal LED keeps on in green You can use remote controller to change the host into arming status or you may send command 123456 1 1 to arm activate th
4. the system will be alarming and the host will send the SMS and dial out How to add more detectors You can add more sensors and detectors such as wireless door sensors PIR sensors gas and smoke detectors into the host 1 Add sensors ready to work when you set both Out Arm and Home Arm When the GSM host begins to be powered on the status LED light on panel will be red for 20 seconds this is code learning mode You can trigger the sensors or detectors and the red LED will flash to show it is coded successfully into the host The coding mode ends 20 seconds later automatically and system enters into working mode status LED light on panel will change to yellow then to green 2 Add sensors into inner defense zone Detectors in this zone are ready to work when you set Out Arm and will not work when you set Home Arm When the GSM host begins to be powered on the status LED light on panel will be red Push the reset button for one second the status LED light will light up in orange for 20 seconds This is code learning mode of inner defense zone You can trigger the sensors or detectors the LED will flash in red to show it is coded successfully into inner defense zone For above operation the host will exit code learning mode 20 seconds later automatically and enters into working mode the light on panel changes to orange to search for GSM network then to green Note If there were 4 wireless sensors in the host stand for zone 1 t
5. Business Home GSM Alarm System Model No GSM 007M Installation and Users guide O Horn p _ oor Detector Brief Introduction GSM 900 1800MHZ bands can be used in most parts of the world Full duplex 2 way communication with the host optional Voice monitoring the scene environment Voice and message alert Set alarm ON or OFF Arm disarm by remote controllers Can set Home Arm and Out Arm mode and time delay alarm Call in to set alarm ON OFF Monitor Output and Intercom Send SMS to set alarm ON OFF Monitor Output 5 group phone Room zone number 1 group alarm monitor center phone number 2 group phone to report arm and disarm status Can program 5 groups of alarm messages 3 zones for wired detectors 99 zones for wireless detectors 2 outputs can be used with external circuit to control home appliance Easily set ON or OFF for every wired or wireless detector SMS alert if external power failure or recovery HHH HHHHHHHHHHH HF Basic Kit contains GSM Alarm system control unit 1 pe Wireless PIR detector 1 pc Wireless door gap sensor 1 pc Remote controller 2 pcs GSM Antenna Ipc Mini wired siren 110dB 0 3m 1 pc Power supply adapter Ipc Installation user manual Ipc Installation guide 1 Insert SIM in alarm unit Press the yellow point on top of the main unit with a pencil tip or other tools SIM tray will come out Put the SIM ca
6. and to the host Such as DisArm Sms ON Phone ON Siren ON Center Tel OFF Arm Center Tel OFF DisArm Center Tel OFF If the replied message is about the current status of the host you may have sent wrong command 4 You can also send inquiry command to check out the present status of the host 5 When the external power is cut off the system will send SMS Power changer off to inform When the external power resumed the system will send SMS Power changer on to inform How to use remote controllers I Out Arm r R Gd D There are four buttons on the remote controller Out Arm key Press this button the signal LED flash slowly in orange for 10 seconds system is in arm wait status 10 seconds later the signal LED flash slowly in green system is in out arm status now You can set out arm mode when no one is at home all the detectors at home will be in working mode Home Arm key Press this button the signal LED flash slowly in orange for 10 seconds system is in arm wait status 10 seconds later the signal LED will flash quickly in green system is in home arm status now You can set home arm mode when there is some one at home sensors in inner defense zone will be invalid but sensors in other defense zones still work normally Disarm key Press this button all the detectors are disarmed the light on panel will keep on in green Alarm SOS key Press this button the light on panel will flash in red
7. e alarm the signal LED will flash in green under arming mode l Under arming mode any port of input 11 I2 I3 touches ground or let it open or wireless detectors activated or press of alarm key of the controller the alarm system will send alarm information by SMS and dial out pre stored telephone numbers after that The system will send preset alarm message before dialing alarm phone numbers If the SMS has been closed or limited it will only dial out the alarm telephone numbers When there is alarm you can answer the phone no need to input password for listen in remote control Press 3 1 to sound the siren and press 3 0 to stop it press 4 1 to start to listen in and press 4 0 to stop it press 93 1 to start to talk to the host and press 93 0 to stop it After picking up alarming calls if you do not need the host dial next phone number programmed in the host just press 1 1 or 1 2 to re turn the host to arm status When there is alarm users can also use the controller to disarm the host if they are near by In normal usage with inside recharge battery on you will receive the message external power failure or external power recovery when external power supply lost or recovered How to control the host 1 Sending message to the host phone number SIM Card number Send the message to the host enter password 123456 add the following command to set the host 2 Calling the host phone number SIM Ca
8. ensors Three inputs are available to connect wired sensors Inputs are independent and are not coded as different zones Sensors must be NC normally closed type More than 1 sensor can be applied at one input connecting their alarm contacts serial The inputs can be connected with any number of wired sensors as long as total resistance is under 220 ohms When these sensors are triggered the alarming message will be Wired Activated 1 3 a Wired sensors a 0 JOO000 jaa s0 O3 Oo 13 12 11 SIM RESET OFF OW ANT pc12 fl 6 Connecting switched output devices Home appliance Control Three open outputs O1 O2 and O3 and one internal relay controlled by telephone are available Internal onboard relay is activated when an alarm occurs and can be deactivated reactivated through telephone commands or SMS text message It can be used for example to command an external light LAMP AC220V oe Gan lo CUTIE eQ 0012 fico 6Q30201 5hh SIM RESET OFF CH ANT Open outputs can be used directly if your equipment can operate a relay Do connect an anti parallel diode with relay coil These outputs can be operated only by telephone or SMS text message commands Wiring Explanation For home appliance control for special order The controller box has four wires 1 Two yellow AC 220 wires to be connected with Home appliance 2 GND 12V DC wires to be connected with a 12V DC Power su
9. ing center phone number 0 15 digits and user s ID number 4 digits 78 Save arm center phone number 0 15 digits 79 Save disarm center phone number 0 15 digits S0 show preset SMS in the host 81 First group Message 0 24bit 82 Second group Message 0 24bit 83 Third group Message 0 24bit 84 Fourth group Message 0 24bit 85 Fifth group Message 0 24bit 86 Sixth group Message 0 24bit 87 To change the SMS content for zone 7 zone 99 90 Show Output status in the host 91 1 Set Output 1 change to high 91 0 Set Output 1 change to low 92 1 Set Output 2 change to high 92 0 Set Output 2 change to low 93 1 Set talk to the host available Output 3 93 0 Set talk to the host unavailable Output 3 94 1 Set Relay to be connected 94 0 Set Relay to be disconnected O5 1 Set alarm when line input 1 open 95 0 Set alarm when line input 1 connect to Gnd 96 1 Set alarm when line input 2 open 96 0 Set alarm when line input 2connect to Gnd O7T I Set alarm when line input 3 open 97 0 Set alarm when line input 3connect to Gnd Note 1 Above table stands for default setting 2 Inthe above phone operation one beep shows the number your input is successful a long beep shows the sentence you input is successful two short beeps show sentence you input is failed you should try again 3 Inthe above SMS operation you will receive a reply message for confirmation after sending message comm
10. o save first group alarm phone number into the host 123456 52 13907550002 to save second group alarm phone number into the host 123456 53 13907550003 to save third group alarm phone number into the host 123456 54 13907550004 to save fourth group alarm phone number into the host 123456 55 13907550005 to save fifth group alarm phone number into the host Set monitoring center phone number The format is Password 71 monitoring center phone number ID Number After this command was sent the host will dial the monitoring center phone number when there is an alarm and will show its ID Number in the monitoring center For example you can send 723456 71 88886666 0001 It shows the monitoring center number is 88886666 user s ID number is 0001 Note The monitoring center number should be no more than 15 digits ID Number should be 4 digits If there is no monitoring center no need to set this command There are 7 kinds of alarm messages in the host The first five messages are for wireless detectors of zone 1 5 the sixth message is for wireless detectors of zone 6 16 the seventh message is for wired port I1 I2 I3 If the first wireless detector is triggered the alarm message is Wireless Activated 01 If the second wireless detector is triggered the alarm message is Wireless Activated 02 If the third wireless detector is triggered the alarm message is Wireless Activated 03 If the fourth wireless detector is triggered
11. o zone 4 then the new added sensor will be 5th zone in the host How to cancel the lost detectors In case some of the coded detectors are lost you can cancel the coded information of this detector so that it can not control your alarm system Follow the below operation to reset the alarm system Keep pressing the reset button then power on the system Siren beeps once or LED flashes once it shows reset is successful All registered detectors have been deleted You can register them again with the above mentioned process System reset will not change SMS message SOME NOTES 1 About SIGNAL light SIGNAL light keeps on red in 20 seconds after the host is powered on wireless detectors can be coded into the host this time The light flash in red if coded successfully 20 seconds later SIGNAL light flash in orange to show it starts to search for GSM network If SIGNAL light still flashes in orange it shows SIM card is fixed incorrectly or GSM network is poor If SIGNAL light still on in green it shows no name or phone numbers in SIM card If every thing is ok SIGNAL light will flash slowly in green out arm mode or flash quickly in green home arm mode or keeps on in green disarm mode If alarm happened SIGNAL light will flash in red and start to dial out and send SMS 2 About OUTPUT light If host O1 output high 5V the OUT 1 light will be on If host O2 output high 5V the OUT 2 light will be on 3 About TALK
12. pply Configuration of the host There are 10 connector ports on top of the host GND SIREN RELAY1 RELAY2 SPEAKER O3 02 O1 I3 12 I1 I1 12 I3 These 3 ports for input every port can be connected with ground or open to make alarm out O1 02 These 2 ports for output you can call in or send SMS to set it If output of these ports goes high the light of OUT 1 or OUT 2 will light on the panel NOTE these ports must be connected with external circuit un professionals should use with caution SPEAKER 03 This port is for voice output it can be connected to the speaker The other port of the speaker is connected to ground You can control it by call in or send the SMS If this function avails the light of OUT 3 will light on the panel RELAY1 RELAY 2 These two ports will be closed for 3 minutes when alarm happens You can use these two ports to start the power supply of the camera when alarm happens This function can be disabled by set command 16 1 You can also make this relay close or open anytime by sending SMS or phone calls 94 1 or 94 0 SIREN This port outputs siren tone alarm it is to be connected with the siren The other port of siren to be connected to ground GND power ground How to setup the alarm phone numbers and SMS 1 You can send command to the host Control panel to setup 5 groups of alarm receiving phone numbers The format is Password operation code content 123456 51 13907550001 t
13. rd carefully into the tray and make sure the metal contacts of the SIM to be down Note Before inserting SIM card into alarm unit using a regular mobile phone to do the following steps Set PIN code request to off Delete all stored numbers 2 Connect the antenna Screw the antenna to the connection on top of the main unit Take care not to over tight the nut or let it loose 3 Insert the power supply Connect the host with the adaptor The host need 9V 12V DC must be over 1000mA current The signal status LED on the main unit panel will turn to red and last for 20 seconds this is code learning mode system is waiting for wireless detectors to be coded into the host After 20 seconds the signal status LED will turn to orange and begin to flash indicating system is checking SIM card and search for GSM network After main unit finish checking the host if the signal status LED turns to green and flashes slowly it shows alarm phone number have been saved in the host and the host is in arm status If the signal status LED keeps on in green it shows phone numbers have not been saved in the host and the host is in disarm status You can dial in the host or send SMS to program the phone number 4 Connect the siren to alarm system Connect the black wire to GND port and red wire to siren port 0 Black Red GND Oo IDOL axa DC12 Tt s 03 O201 It SIM RESET OFF OW ANT 5 Connect wired s
14. rd number Call in the host and enter password 123456 then input the following command to set the host Com Function Com Function 1 1 Outdoor arm all detectors work 1 2 Indoor arm part detectors work 1 0 Disarm all detectors not work 3 1 Sounding immediately 3 0 Stop sounding 4 1 Open listen in use phone key 4 0 Closed listen in use phone key ll 1 Need siren sound when alarming 11 0 No siren sound when alarming 12 1 Sending SMS when alarming 12 0 No SMS when alarming 15 1 Dial phone number when alarming 15 0 Just alarm and no dialing 16 1 Disable Relay close 3 Min when alarming 16 0 Set Relay close 3 Min when alarm 30 show the arm and disarm status of every zone 31 Change password Enter a new password 1 6 bit 38 Set up alarm of zone wireless zone 1 16 wire zone 21 23 NOTE arm of single defense zone 39 Turn off alarm of zone wireless zone 1 16 wire zone 21 23 NOTE disarm of single defense zone S0 show preset phone number in the host 51 First group phone number 0 1 5bit 52 Second group phone number 0 1 5bit 53 Third group phone number 0 1 5bit 54 fourth group phone number 0 15bit 55 Fifth group phone number 0 1 5bit 70 Show monitor center phone number in the host 71 Save monitor